- RFMXSPECAN_ATTR_ACP_MEASUREMENT_ENABLED
- Carrier
-
Offset
- RFMXSPECAN_ATTR_ACP_NUMBER_OF_OFFSETS
- RFMXSPECAN_ATTR_ACP_OFFSET_ENABLED
- RFMXSPECAN_ATTR_ACP_OFFSET_FREQUENCY
- RFMXSPECAN_ATTR_ACP_OFFSET_SIDEBAND
- Offset Power Reference
- RFMXSPECAN_ATTR_ACP_OFFSET_INTEGRATION_BANDWIDTH
- RFMXSPECAN_ATTR_ACP_OFFSET_RELATIVE_ATTENUATION
- RRC Filter
- RFMXSPECAN_ATTR_ACP_OFFSET_FREQUENCY_DEFINITION
- RBW Filter
- Sweep Time
- RFMXSPECAN_ATTR_ACP_POWER_UNITS
- RFMXSPECAN_ATTR_ACP_MEASUREMENT_METHOD
- Noise Calibration
- Noise Compensation
- Averaging
- FFT
- RFMXSPECAN_ATTR_ACP_MEASUREMENT_MODE
- Advanced
- RFMXSPECAN_ATTR_ACP_AMPLITUDE_CORRECTION_TYPE
- RFMXSPECAN_ATTR_ACP_ALL_TRACES_ENABLED
- RFMXSPECAN_ATTR_ACP_NUMBER_OF_ANALYSIS_THREADS
-
Results
- RFMXSPECAN_ATTR_ACP_RESULTS_TOTAL_CARRIER_POWER
- RFMXSPECAN_ATTR_ACP_RESULTS_FREQUENCY_RESOLUTION
- Carrier
-
Lower Offset
- RFMXSPECAN_ATTR_ACP_RESULTS_LOWER_OFFSET_FREQUENCY_REFERENCE_CARRIER
- RFMXSPECAN_ATTR_ACP_RESULTS_LOWER_OFFSET_FREQUENCY
- RFMXSPECAN_ATTR_ACP_RESULTS_LOWER_OFFSET_INTEGRATION_BANDWIDTH
- RFMXSPECAN_ATTR_ACP_RESULTS_LOWER_OFFSET_POWER_REFERENCE_CARRIER
- RFMXSPECAN_ATTR_ACP_RESULTS_LOWER_OFFSET_ABSOLUTE_POWER
- RFMXSPECAN_ATTR_ACP_RESULTS_LOWER_OFFSET_RELATIVE_POWER
-
Upper Offset
- RFMXSPECAN_ATTR_ACP_RESULTS_UPPER_OFFSET_FREQUENCY_REFERENCE_CARRIER
- RFMXSPECAN_ATTR_ACP_RESULTS_UPPER_OFFSET_FREQUENCY
- RFMXSPECAN_ATTR_ACP_RESULTS_UPPER_OFFSET_INTEGRATION_BANDWIDTH
- RFMXSPECAN_ATTR_ACP_RESULTS_UPPER_OFFSET_POWER_REFERENCE_CARRIER
- RFMXSPECAN_ATTR_ACP_RESULTS_UPPER_OFFSET_ABSOLUTE_POWER
- RFMXSPECAN_ATTR_ACP_RESULTS_UPPER_OFFSET_RELATIVE_POWER
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies whether to enable the ACP measurement. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXSPECAN_VAL_FALSE. Get Function: RFmxSpecAn_ACPGetMeasurementEnabled Set Function: RFmxSpecAn_ACPSetMeasurementEnabled |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies the number of carriers. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is 1. Get Function: RFmxSpecAn_ACPGetNumberOfCarriers Set Function: RFmxSpecAn_ACPSetNumberOfCarriers |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies whether to consider the carrier power as part of the total carrier power measurement. Use 'carrier(n)' as the selector string to configure or read this attribute. The default value is RFMXSPECAN_VAL_ACP_CARRIER_MODE_ACTIVE. Get Function: RFmxSpecAn_ACPGetCarrierMode Set Function: RFmxSpecAn_ACPSetCarrierMode |
Values: |
RFMXSPECAN_VAL_ACP_CARRIER_MODE_PASSIVE (0) | The carrier power is not considered as part of the total carrier power. |
---|---|
RFMXSPECAN_VAL_ACP_CARRIER_MODE_ACTIVE (1) | The carrier power is considered as part of the total carrier power. |
Data Type: | float64 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeF64 RFmxSpecAn_GetAttributeF64 |
Description: | Specifies the center frequency of the carrier, relative to the RF center frequency. This value is expressed in Hz. Use 'carrier(n)' as the selector string to configure or read this attribute. The default value is 0. Get Function: RFmxSpecAn_ACPGetCarrierFrequency Set Function: RFmxSpecAn_ACPSetCarrierFrequency |
Data Type: | float64 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeF64 RFmxSpecAn_GetAttributeF64 |
Description: | Specifies the frequency range over which the measurement integrates the carrier power. This value is expressed in Hz. Use 'carrier(n)' as the selector string to configure or read this attribute. The default value is 1 MHz. Get Function: RFmxSpecAn_ACPGetCarrierIntegrationBandwidth Set Function: RFmxSpecAn_ACPSetCarrierIntegrationBandwidth |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies whether to apply the root-raised-cosine (RRC) filter on the acquired carrier channel before measuring the carrier channel power. Use 'carrier(n)' as the selector string to configure or read this attribute. The default value is RFMXSPECAN_VAL_ACP_CARRIER_RRC_FILTER_ENABLED_FALSE. Get Function: RFmxSpecAn_ACPGetCarrierRRCFilterEnabled Set Function: RFmxSpecAn_ACPSetCarrierRRCFilterEnabled |
Values: |
RFMXSPECAN_VAL_ACP_CARRIER_RRC_FILTER_ENABLED_FALSE (0) | The channel power of the acquired carrier channel is measured directly. |
---|---|
RFMXSPECAN_VAL_ACP_CARRIER_RRC_FILTER_ENABLED_TRUE (1) | The measurement applies the RRC filter on the acquired carrier channel before measuring the carrier channel power. |
Data Type: | float64 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeF64 RFmxSpecAn_GetAttributeF64 |
Description: | Specifies the roll-off factor for the root-raised-cosine (RRC) filter. Use 'carrier(n)' as the selector string to configure or read this attribute. The default value is 0.1. Get Function: RFmxSpecAn_ACPGetCarrierRRCFilterAlpha Set Function: RFmxSpecAn_ACPSetCarrierRRCFilterAlpha |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies the number of offset channels. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is 1. Get Function: RFmxSpecAn_ACPGetNumberOfOffsets Set Function: RFmxSpecAn_ACPSetNumberOfOffsets |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies whether to enable the offset channel for ACP measurement. Use 'offset(n)' as the selector string to configure or read this attribute. The default value is RFMXSPECAN_VAL_ACP_OFFSET_FREQUENCY_ENABLED_TRUE. Get Function: RFmxSpecAn_ACPGetOffsetEnabled Set Function: RFmxSpecAn_ACPSetOffsetEnabled |
Values: |
RFMXSPECAN_VAL_ACP_OFFSET_FREQUENCY_ENABLED_FALSE (0) | Disables the offset channel for ACP measurement. |
---|---|
RFMXSPECAN_VAL_ACP_OFFSET_FREQUENCY_ENABLED_TRUE (1) | Enables the offset channel for ACP measurement. |
Data Type: | float64 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeF64 RFmxSpecAn_GetAttributeF64 |
Description: | Specifies the center or edge frequency of the offset channel, relative to the center frequency of the closest carrier as determined by the RFMXSPECAN_ATTR_ACP_OFFSET_FREQUENCY_DEFINITION attribute. This value is expressed in Hz. The sign of offset frequency is ignored and the RFMXSPECAN_ATTR_ACP_OFFSET_SIDEBAND attribute determines whether the upper, lower, or both offsets are measured. Use 'offset(n)' as the selector string to configure or read this attribute. The default value is 1 MHz. Get Function: RFmxSpecAn_ACPGetOffsetFrequency Set Function: RFmxSpecAn_ACPSetOffsetFrequency |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies whether the offset channel is present on one side, or on both sides of the carrier. Use 'offset(n)' as the selector string to configure or read this attribute. The default value is RFMXSPECAN_VAL_ACP_OFFSET_SIDEBAND_BOTH. Get Function: RFmxSpecAn_ACPGetOffsetSideband Set Function: RFmxSpecAn_ACPSetOffsetSideband |
Values: |
RFMXSPECAN_VAL_ACP_OFFSET_SIDEBAND_NEGATIVE (0) | Configures a lower offset segment to the left of the leftmost carrier. |
---|---|
RFMXSPECAN_VAL_ACP_OFFSET_SIDEBAND_POSITIVE (1) | Configures an upper offset segment to the right of the rightmost carrier. |
RFMXSPECAN_VAL_ACP_OFFSET_SIDEBAND_BOTH (2) | Configures both negative and positive offset segments. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies the carrier to be used as power reference to measure the offset channel relative power. The offset channel power is measured only if you set the RFMXSPECAN_ATTR_ACP_CARRIER_MODE attribute of the reference carrier to RFMXSPECAN_VAL_ACP_CARRIER_MODE_ACTIVE. Use 'offset(n)' as the selector string to configure or read this attribute. The default value is RFMXSPECAN_VAL_ACP_OFFSET_POWER_REFERENCE_CARRIER_CLOSEST. Get Function: RFmxSpecAn_ACPGetOffsetPowerReferenceCarrier Set Function: RFmxSpecAn_ACPSetOffsetPowerReferenceCarrier |
Values: |
RFMXSPECAN_VAL_ACP_OFFSET_POWER_REFERENCE_CARRIER_CLOSEST (0) | The measurement uses the power measured in the carrier closest to the offset channel center frequency, as the power reference. |
---|---|
RFMXSPECAN_VAL_ACP_OFFSET_POWER_REFERENCE_CARRIER_HIGHEST (1) | The measurement uses the highest power measured among all the active carriers as the power reference. |
RFMXSPECAN_VAL_ACP_OFFSET_POWER_REFERENCE_CARRIER_COMPOSITE (2) | The measurement uses the sum of powers measured in all the active carriers as the power reference. |
RFMXSPECAN_VAL_ACP_OFFSET_POWER_REFERENCE_CARRIER_SPECIFIC (3) | The measurement uses the power measured in the carrier that has an index specified by the RFMXSPECAN_ATTR_ACP_OFFSET_POWER_REFERENCE_SPECIFIC attribute, as the power reference. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies the index of the carrier to be used as the reference carrier. The power measured in this carrier is used as the power reference for measuring the offset channel relative power, when you set the RFMXSPECAN_ATTR_ACP_OFFSET_POWER_REFERENCE_CARRIER attribute to RFMXSPECAN_VAL_ACP_OFFSET_POWER_REFERENCE_CARRIER_SPECIFIC. Use 'offset(n)' as the selector string to configure or read this attribute. The default value is 0. Get Function: RFmxSpecAn_ACPGetOffsetPowerReferenceSpecific Set Function: RFmxSpecAn_ACPSetOffsetPowerReferenceSpecific |
Data Type: | float64 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeF64 RFmxSpecAn_GetAttributeF64 |
Description: | Specifies the frequency range, over which the measurement integrates the offset channel power. This value is expressed in Hz. Use 'offset(n)' as the selector string to configure or read this attribute. The default value is 1 MHz. Get Function: RFmxSpecAn_ACPGetOffsetIntegrationBandwidth Set Function: RFmxSpecAn_ACPSetOffsetIntegrationBandwidth |
Data Type: | float64 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeF64 RFmxSpecAn_GetAttributeF64 |
Description: | Specifies the attenuation relative to the external attenuation specified by the RFMXSPECAN_ATTR_EXTERNAL_ATTENUATION attribute. This value is expressed in dB. Use the ACP Offset Rel Attn attribute to compensate for variations in external attenuation when the offset channels are spread wide in frequency. Use 'offset(n)' as the selector string to configure or read this attribute. The default value is 0. Get Function: RFmxSpecAn_ACPGetOffsetRelativeAttenuation Set Function: RFmxSpecAn_ACPSetOffsetRelativeAttenuation |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies whether to apply the root-raised-cosine (RRC) filter on the acquired offset channel before measuring the offset channel power. Use 'offset(n)' as the selector string to configure or read this attribute. The default value is RFMXSPECAN_VAL_ACP_OFFSET_RRC_FILTER_ENABLED_FALSE. Get Function: RFmxSpecAn_ACPGetOffsetRRCFilterEnabled Set Function: RFmxSpecAn_ACPSetOffsetRRCFilterEnabled |
Values: |
RFMXSPECAN_VAL_ACP_OFFSET_RRC_FILTER_ENABLED_FALSE (0) | The channel power of the acquired offset channel is measured directly. |
---|---|
RFMXSPECAN_VAL_ACP_OFFSET_RRC_FILTER_ENABLED_TRUE (1) | The measurement applies the RRC filter on the acquired offset channel before measuring the offset channel power. |
Data Type: | float64 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeF64 RFmxSpecAn_GetAttributeF64 |
Description: | Specifies the roll-off factor for the root-raised-cosine (RRC) filter. Use 'offset(n)' as the selector string to configure or read this attribute. The default value is 0.1. Get Function: RFmxSpecAn_ACPGetOffsetRRCFilterAlpha Set Function: RFmxSpecAn_ACPSetOffsetRRCFilterAlpha |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies the offset frequency definition used to specify the RFMXSPECAN_ATTR_ACP_OFFSET_FREQUENCY attribute. Use 'offset(n)' as the selector string to configure or read this attribute. The default value is RFMXSPECAN_VAL_ACP_CARRIER_CENTER_TO_OFFSET_CENTER. Get Function: RFmxSpecAn_ACPGetOffsetFrequencyDefinition Set Function: RFmxSpecAn_ACPSetOffsetFrequencyDefinition |
Values: |
RFMXSPECAN_VAL_ACP_CARRIER_CENTER_TO_OFFSET_CENTER (0) | The offset frequency is defined from the center of the closest carrier to the center of the offset channel. |
---|---|
RFMXSPECAN_VAL_ACP_CARRIER_CENTER_TO_OFFSET_EDGE (1) | The offset frequency is defined from the center of the closest carrier to the nearest edge of the offset channel. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies whether the measurement computes the resolution bandwidth (RBW). You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXSPECAN_VAL_ACP_RBW_AUTO_TRUE. Get Function: RFmxSpecAn_ACPGetRBWFilterAutoBandwidth Set Function: RFmxSpecAn_ACPSetRBWFilterAutoBandwidth |
Values: |
RFMXSPECAN_VAL_ACP_RBW_AUTO_FALSE (0) | The measurement uses the RBW that you specify in the RFMXSPECAN_ATTR_ACP_RBW_FILTER_BANDWIDTH attribute. |
---|---|
RFMXSPECAN_VAL_ACP_RBW_AUTO_TRUE (1) | The measurement computes the RBW. |
Data Type: | float64 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeF64 RFmxSpecAn_GetAttributeF64 |
Description: | Specifies the bandwidth of the resolution bandwidth (RBW) filter used to sweep the acquired signal, when you set the RFMXSPECAN_ATTR_ACP_RBW_FILTER_AUTO_BANDWIDTH attribute to RFMXSPECAN_VAL_ACP_RBW_AUTO_FALSE. This value is expressed in Hz. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is 10 kHz. Get Function: RFmxSpecAn_ACPGetRBWFilterBandwidth Set Function: RFmxSpecAn_ACPSetRBWFilterBandwidth |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies the shape of the digital resolution bandwidth (RBW) filter. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXSPECAN_VAL_ACP_RBW_FILTER_TYPE_GAUSSIAN. Get Function: RFmxSpecAn_ACPGetRBWFilterType Set Function: RFmxSpecAn_ACPSetRBWFilterType |
Values: |
RFMXSPECAN_VAL_ACP_RBW_FILTER_TYPE_FFT_BASED (0) | No RBW filtering is performed. |
---|---|
RFMXSPECAN_VAL_ACP_RBW_FILTER_TYPE_GAUSSIAN (1) | An RBW filter with a Gaussian response is applied. |
RFMXSPECAN_VAL_ACP_RBW_FILTER_TYPE_FLAT (2) | An RBW filter with a flat response is applied. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies the bandwidth definition which you use to specify the value of the RFMXSPECAN_ATTR_ACP_RBW_FILTER_BANDWIDTH attribute. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXSPECAN_VAL_ACP_RBW_FILTER_BANDWIDTH_DEFINITION_3DB. Get Function: RFmxSpecAn_ACPGetRBWFilterBandwidthDefinition Set Function: RFmxSpecAn_ACPSetRBWFilterBandwidthDefinition |
Values: |
RFMXSPECAN_VAL_ACP_RBW_FILTER_BANDWIDTH_DEFINITION_3DB (0) | Defines the RBW in terms of the 3dB bandwidth of the RBW filter. When you set the RFMXSPECAN_ATTR_ACP_RBW_FILTER_TYPE attribute to RFMXSPECAN_VAL_ACP_RBW_FILTER_TYPE_FFT_BASED, RBW is the 3dB bandwidth of the window specified by the RFMXSPECAN_ATTR_ACP_FFT_WINDOW attribute. |
---|---|
RFMXSPECAN_VAL_ACP_RBW_FILTER_BANDWIDTH_DEFINITION_BIN_WIDTH (2) | Defines the RBW in terms of the bin width of the spectrum computed using FFT when you set the RFMXSPECAN_ATTR_ACP_RBW_FILTER_TYPE attribute to FFT Based. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies whether the measurement computes the sweep time. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXSPECAN_VAL_ACP_SWEEP_TIME_AUTO_TRUE. Get Function: RFmxSpecAn_ACPGetSweepTimeAuto Set Function: RFmxSpecAn_ACPSetSweepTimeAuto |
Values: |
RFMXSPECAN_VAL_ACP_SWEEP_TIME_AUTO_FALSE (0) | The measurement uses the sweep time that you specify in the RFMXSPECAN_ATTR_ACP_SWEEP_TIME_INTERVAL attribute. |
---|---|
RFMXSPECAN_VAL_ACP_SWEEP_TIME_AUTO_TRUE (1) | The measurement calculates the sweep time based on the value of the RFMXSPECAN_ATTR_ACP_RBW_FILTER_BANDWIDTH attribute. |
Data Type: | float64 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeF64 RFmxSpecAn_GetAttributeF64 |
Description: | Specifies the sweep time when you set the RFMXSPECAN_ATTR_ACP_SWEEP_TIME_AUTO attribute to RFMXSPECAN_VAL_ACP_SWEEP_TIME_AUTO_FALSE. This value is expressed in seconds. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is 0.001. Get Function: RFmxSpecAn_ACPGetSweepTimeInterval Set Function: RFmxSpecAn_ACPSetSweepTimeInterval |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies the units for the absolute power. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXSPECAN_VAL_ACP_POWER_UNITS_DBM_PER_HZ. Get Function: RFmxSpecAn_ACPGetPowerUnits Set Function: RFmxSpecAn_ACPSetPowerUnits |
Values: |
RFMXSPECAN_VAL_ACP_POWER_UNITS_DBM (0) | The absolute powers are reported in dBm. |
---|---|
RFMXSPECAN_VAL_ACP_POWER_UNITS_DBM_PER_HZ (1) | The absolute powers are reported in dBm/Hz. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies the method for performing the ACP measurement. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXSPECAN_VAL_ACP_MEASUREMENT_METHOD_NORMAL. Get Function: RFmxSpecAn_ACPGetMeasurementMethod Set Function: RFmxSpecAn_ACPSetMeasurementMethod |
Values: |
RFMXSPECAN_VAL_ACP_MEASUREMENT_METHOD_NORMAL (0) | The ACP measurement acquires the spectrum using the same signal analyzer setting across frequency bands. Use this method when measurement speed is desirable over higher dynamic range. |
---|---|
RFMXSPECAN_VAL_ACP_MEASUREMENT_METHOD_DYNAMIC_RANGE (1) | The ACP measurement acquires the spectrum using the hardware-specific optimizations for different frequency bands. Use this method to get the best dynamic range. Supported devices: PXIe-5665/5668 |
RFMXSPECAN_VAL_ACP_MEASUREMENT_METHOD_SEQUENTIAL_FFT (2) | The ACP measurement acquires I/Q samples for a duration specified by the RFMXSPECAN_ATTR_ACP_SWEEP_TIME_INTERVAL attribute. These samples are divided into smaller chunks. The size of each chunk is defined by the RFMXSPECAN_ATTR_ACP_SEQUENTIAL_FFT_SIZE attribute. The overlap between the chunks is defined by the RFMXSPECAN_ATTR_ACP_FFT_OVERLAP_MODE attribute. FFT is computed on each of these chunks. The resultant FFTs are averaged to get the spectrum and is used to compute ACP. If the total acquired samples is not an integer multiple of the FFT size, the remaining samples at the end of acquisition are not used for the measurement. Use this method to optimize ACP measurement speed. Accuracy of the results may be reduced when using this measurement method. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies whether the noise calibration and measurement is performed manually by the user or automatically by RFmx. Refer to the measurement guidelines section in the Noise Compensation Algorithm topic for more information. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXSPECAN_VAL_ACP_NOISE_CALIBRATION_MODE_AUTO. Get Function: RFmxSpecAn_ACPGetNoiseCalibrationMode Set Function: RFmxSpecAn_ACPSetNoiseCalibrationMode |
Values: |
RFMXSPECAN_VAL_ACP_NOISE_CALIBRATION_MODE_MANUAL (0) | When you set the RFMXSPECAN_ATTR_ACP_MEASUREMENT_MODE attribute to RFMXSPECAN_VAL_ACP_MEASUREMENT_MODE_CALIBRATE_NOISE_FLOOR, you can initiate instrument noise calibration for the ACP measurement manually. When you set the RFMXSPECAN_ATTR_ACP_MEASUREMENT_MODE attribute to RFMXSPECAN_VAL_ACP_MEASUREMENT_MODE_MEASURE, you can initiate the ACP measurement manually. |
---|---|
RFMXSPECAN_VAL_ACP_NOISE_CALIBRATION_MODE_AUTO (1) | When you set the RFMXSPECAN_ATTR_ACP_NOISE_COMPENSATION_ENABLED to RFMXSPECAN_VAL_ACP_NOISE_COMPENSATION_ENABLED_TRUE, RFmx sets the Input Isolation Enabled attribute to Enabled and calibrates the instrument noise in the current state of the instrument. RFmx then resets the Input Isolation Enabled attribute and performs the ACP measurement, including compensation for noise of the instrument. RFmx skips noise calibration in this mode if valid noise calibration data is already cached. When you set the RFMXSPECAN_ATTR_ACP_NOISE_COMPENSATION_ENABLED attribute to RFMXSPECAN_VAL_ACP_NOISE_COMPENSATION_ENABLED_FALSE, RFmx does not calibrate instrument noise and only performs the ACP measurement without compensating for noise of the instrument. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies whether RFmx automatically computes the averaging count used for instrument noise calibration. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXSPECAN_VAL_ACP_NOISE_CALIBRATION_AVERAGING_AUTO_TRUE. Get Function: RFmxSpecAn_ACPGetNoiseCalibrationAveragingAuto Set Function: RFmxSpecAn_ACPSetNoiseCalibrationAveragingAuto |
Values: |
RFMXSPECAN_VAL_ACP_NOISE_CALIBRATION_AVERAGING_AUTO_FALSE (0) | RFmx uses the averages that you set for the RFMXSPECAN_ATTR_ACP_NOISE_CALIBRATION_AVERAGING_COUNT attribute. |
---|---|
RFMXSPECAN_VAL_ACP_NOISE_CALIBRATION_AVERAGING_AUTO_TRUE (1) | When you set the RFMXSPECAN_ATTR_ACP_MEASUREMENT_METHOD attribute to RFMXSPECAN_VAL_ACP_MEASUREMENT_METHOD_NORMAL, RFmx uses a noise calibration averaging count of 32. When you set the RFMXSPECAN_ATTR_ACP_MEASUREMENT_METHOD attribute to RFMXSPECAN_VAL_ACP_MEASUREMENT_METHOD_DYNAMIC_RANGE and the sweep time is less than 5 ms, RFmx uses a noise calibration averaging count of 15. When you set the RFMXSPECAN_ATTR_ACP_MEASUREMENT_METHOD attribute to RFMXSPECAN_VAL_ACP_MEASUREMENT_METHOD_DYNAMIC_RANGE and the sweep time is greater than or equal to 5 ms, RFmx uses a noise calibration averaging count of 5. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies the averaging count used for noise calibration when you set the RFMXSPECAN_ATTR_ACP_NOISE_CALIBRATION_AVERAGING_AUTO attribute to RFMXSPECAN_VAL_ACP_NOISE_CALIBRATION_AVERAGING_AUTO_FALSE. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is 32. Get Function: RFmxSpecAn_ACPGetNoiseCalibrationAveragingCount Set Function: RFmxSpecAn_ACPSetNoiseCalibrationAveragingCount |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies whether RFmx compensates for the instrument noise while performing the measurement when you set the RFMXSPECAN_ATTR_ACP_NOISE_CALIBRATION_MODE attribute to RFMXSPECAN_VAL_ACP_NOISE_CALIBRATION_MODE_AUTO, or when you set the RFMXSPECAN_ATTR_ACP_NOISE_CALIBRATION_MODE attribute to RFMXSPECAN_VAL_ACP_NOISE_CALIBRATION_MODE_MANUAL and RFMXSPECAN_ATTR_ACP_MEASUREMENT_MODE to RFMXSPECAN_VAL_ACP_MEASUREMENT_MODE_MEASURE. Refer to the Noise Compensation Algorithm topic for more information. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXSPECAN_VAL_ACP_NOISE_COMPENSATION_ENABLED_FALSE. Get Function: RFmxSpecAn_ACPGetNoiseCompensationEnabled Set Function: RFmxSpecAn_ACPSetNoiseCompensationEnabled |
Values: |
RFMXSPECAN_VAL_ACP_NOISE_COMPENSATION_ENABLED_FALSE (0) | Disables noise compensation. |
---|---|
RFMXSPECAN_VAL_ACP_NOISE_COMPENSATION_ENABLED_TRUE (1) | Enables noise compensation. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies the noise compensation type. Refer to the Noise Compensation Algorithm topic for more information. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXSPECAN_VAL_ACP_NOISE_COMPENSATION_TYPE_ANALYZER_AND_TERMINATION. Get Function: RFmxSpecAn_ACPGetNoiseCompensationType Set Function: RFmxSpecAn_ACPSetNoiseCompensationType |
Values: |
RFMXSPECAN_VAL_ACP_NOISE_COMPENSATION_TYPE_ANALYZER_AND_TERMINATION (0) | Compensates for noise from the analyzer and the 50-ohm termination. The measured power values are in excess of the thermal noise floor. |
---|---|
RFMXSPECAN_VAL_ACP_NOISE_COMPENSATION_TYPE_ANALYZER_ONLY (1) | Compensates for the analyzer noise only. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies whether to enable averaging for the ACP measurement. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXSPECAN_VAL_ACP_AVERAGING_ENABLED_FALSE. Get Function: RFmxSpecAn_ACPGetAveragingEnabled Set Function: RFmxSpecAn_ACPSetAveragingEnabled |
Values: |
RFMXSPECAN_VAL_ACP_AVERAGING_ENABLED_FALSE (0) | The measurement is performed on a single acquisition. |
---|---|
RFMXSPECAN_VAL_ACP_AVERAGING_ENABLED_TRUE (1) | The ACP measurement uses the RFMXSPECAN_ATTR_ACP_AVERAGING_COUNT attribute as the number of acquisitions over which the ACP measurement is averaged. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies the number of acquisitions used for averaging when you set the RFMXSPECAN_ATTR_ACP_AVERAGING_ENABLED attribute to RFMXSPECAN_VAL_ACP_AVERAGING_ENABLED_TRUE. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is 10. Get Function: RFmxSpecAn_ACPGetAveragingCount Set Function: RFmxSpecAn_ACPSetAveragingCount |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies the averaging type for averaging multiple spectrum acquisitions. The averaged spectrum is used for ACP measurement. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXSPECAN_VAL_ACP_AVERAGING_TYPE_RMS. Get Function: RFmxSpecAn_ACPGetAveragingType Set Function: RFmxSpecAn_ACPSetAveragingType |
Values: |
RFMXSPECAN_VAL_ACP_AVERAGING_TYPE_RMS (0) | The power spectrum is linearly averaged. RMS averaging reduces signal fluctuations but not the noise floor. |
---|---|
RFMXSPECAN_VAL_ACP_AVERAGING_TYPE_LOG (1) | The power spectrum is averaged in a logarithmic scale. |
RFMXSPECAN_VAL_ACP_AVERAGING_TYPE_SCALAR (2) | The square root of the power spectrum is averaged. |
RFMXSPECAN_VAL_ACP_AVERAGING_TYPE_MAXIMUM (3) | The peak power in the spectrum at each frequency bin is retained from one acquisition to the next. |
RFMXSPECAN_VAL_ACP_AVERAGING_TYPE_MINIMUM (4) | The least power in the spectrum at each frequency bin is retained from one acquisition to the next. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies the FFT window type to use to reduce spectral leakage. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXSPECAN_VAL_ACP_FFT_WINDOW_FLAT_TOP. Get Function: RFmxSpecAn_ACPGetFFTWindow Set Function: RFmxSpecAn_ACPSetFFTWindow |
Values: |
RFMXSPECAN_VAL_ACP_FFT_WINDOW_NONE (0) | Analyzes transients for which duration is shorter than the window length. You can also use this window type to separate two tones with frequencies close to each other but with almost equal amplitudes. |
---|---|
RFMXSPECAN_VAL_ACP_FFT_WINDOW_FLAT_TOP (1) | Measures single-tone amplitudes accurately. |
RFMXSPECAN_VAL_ACP_FFT_WINDOW_HANNING (2) | Analyzes transients for which duration is longer than the window length. You can also use this window type to provide better frequency resolution for noise measurements. |
RFMXSPECAN_VAL_ACP_FFT_WINDOW_HAMMING (3) | Analyzes closely-spaced sine waves. |
RFMXSPECAN_VAL_ACP_FFT_WINDOW_GAUSSIAN (4) | Provides a good balance of spectral leakage, frequency resolution, and amplitude attenuation. Hence, this windowing is useful for time-frequency analysis. |
RFMXSPECAN_VAL_ACP_FFT_WINDOW_BLACKMAN (5) | Analyzes single tone because it has a low maximum side lobe level and a high side lobe roll-off rate. |
RFMXSPECAN_VAL_ACP_FFT_WINDOW_BLACKMAN_HARRIS (6) | Useful as a good general purpose window, having side lobe rejection greater than 90 dB and having a moderately wide main lobe. |
RFMXSPECAN_VAL_ACP_FFT_WINDOW_KAISER_BESSEL (7) | Separates two tones with frequencies close to each other but with widely-differing amplitudes. |
Data Type: | float64 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeF64 RFmxSpecAn_GetAttributeF64 |
Description: | Specifies the factor by which the time-domain waveform is zero-padded before fast Fourier transform (FFT). The FFT size is given by the following formula: waveform size * padding This attribute is used only when the acquisition span is less than the device instantaneous bandwidth of the device. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is -1. Get Function: RFmxSpecAn_ACPGetFFTPadding Set Function: RFmxSpecAn_ACPSetFFTPadding |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies the overlap mode when you set the RFMXSPECAN_ATTR_ACP_MEASUREMENT_METHOD attribute to RFMXSPECAN_VAL_ACP_MEASUREMENT_METHOD_SEQUENTIAL_FFT. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXSPECAN_VAL_ACP_FFT_OVERLAP_MODE_DISABLED. Get Function: RFmxSpecAn_ACPGetFFTOverlapMode Set Function: RFmxSpecAn_ACPSetFFTOverlapMode |
Values: |
RFMXSPECAN_VAL_ACP_FFT_OVERLAP_MODE_DISABLED (0) | Disables the overlap between the chunks. |
---|---|
RFMXSPECAN_VAL_ACP_FFT_OVERLAP_MODE_AUTOMATIC (1) | Measurement sets the overlap based on the value you have set for the RFMXSPECAN_ATTR_ACP_FFT_WINDOW attribute. When you set the RFMXSPECAN_ATTR_ACP_FFT_WINDOW attribute to any value other than RFMXSPECAN_VAL_ACP_FFT_WINDOW_NONE, the number of overlapped samples between consecutive chunks is set to 50% of the value of the RFMXSPECAN_ATTR_ACP_SEQUENTIAL_FFT_SIZE attribute. When you set the RFMXSPECAN_ATTR_ACP_FFT_WINDOW attribute to RFMXSPECAN_VAL_ACP_FFT_WINDOW_NONE, the chunks are not overlapped and the overlap is set to 0%. |
RFMXSPECAN_VAL_ACP_FFT_OVERLAP_MODE_USER_DEFINED (2) | Measurement uses the overlap that you specify in the RFMXSPECAN_ATTR_ACP_FFT_OVERLAP attribute. |
Data Type: | float64 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeF64 RFmxSpecAn_GetAttributeF64 |
Description: | Specifies the samples to overlap between the consecutive chunks as a percentage of the RFMXSPECAN_ATTR_ACP_SEQUENTIAL_FFT_SIZE attribute when you set the RFMXSPECAN_ATTR_ACP_MEASUREMENT_METHOD attribute to RFMXSPECAN_VAL_ACP_MEASUREMENT_METHOD_SEQUENTIAL_FFT and the RFMXSPECAN_ATTR_ACP_FFT_OVERLAP_MODE attribute to RFMXSPECAN_VAL_ACP_FFT_OVERLAP_MODE_USER_DEFINED. This value is expressed as a percentage. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is 0. Get Function: RFmxSpecAn_ACPGetFFTOverlap Set Function: RFmxSpecAn_ACPSetFFTOverlap |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies whether the measurement calibrates the noise floor of analyzer or performs the ACP measurement. Refer to the measurement guidelines section in the Noise Compensation Algorithm topic for more information. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXSPECAN_VAL_ACP_MEASUREMENT_MODE_MEASURE. Get Function: RFmxSpecAn_ACPGetMeasurementMode Set Function: RFmxSpecAn_ACPSetMeasurementMode |
Values: |
RFMXSPECAN_VAL_ACP_MEASUREMENT_MODE_MEASURE (0) | ACP measurement is performed on the acquired signal. |
---|---|
RFMXSPECAN_VAL_ACP_MEASUREMENT_MODE_CALIBRATE_NOISE_FLOOR (1) | Manual noise calibration of the signal analyzer is performed for the ACP measurement. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies whether the measurement computes an IF output power level offset for the offset channels to improve the dynamic range of the ACP measurement. This attribute is used only if you set the RFMXSPECAN_ATTR_ACP_MEASUREMENT_METHOD attribute to RFMXSPECAN_VAL_ACP_MEASUREMENT_METHOD_DYNAMIC_RANGE. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXSPECAN_VAL_ACP_IF_OUTPUT_POWER_OFFSET_AUTO_TRUE. Get Function: RFmxSpecAn_ACPGetIFOutputPowerOffsetAuto Set Function: RFmxSpecAn_ACPSetIFOutputPowerOffsetAuto |
Values: |
RFMXSPECAN_VAL_ACP_IF_OUTPUT_POWER_OFFSET_AUTO_FALSE (0) | The measurement sets the IF output power level offset using the values of the RFMXSPECAN_ATTR_ACP_NEAR_IF_OUTPUT_POWER_OFFSET and RFMXSPECAN_ATTR_ACP_FAR_IF_OUTPUT_POWER_OFFSET attributes. |
---|---|
RFMXSPECAN_VAL_ACP_IF_OUTPUT_POWER_OFFSET_AUTO_TRUE (1) | The measurement automatically computes an IF output power level offset for the offset channels to improve the dynamic range of the ACP measurement. |
Data Type: | float64 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeF64 RFmxSpecAn_GetAttributeF64 |
Description: | Specifies the offset by which to adjust the IF output power level for offset channels that are near to the carrier channel to improve the dynamic range. This value is expressed in dB. This attribute is used only if you set the RFMXSPECAN_ATTR_ACP_MEASUREMENT_METHOD attribute to RFMXSPECAN_VAL_ACP_MEASUREMENT_METHOD_DYNAMIC_RANGE and set the RFMXSPECAN_ATTR_ACP_IF_OUTPUT_POWER_OFFSET_AUTO attribute to RFMXSPECAN_VAL_ACP_IF_OUTPUT_POWER_OFFSET_AUTO_FALSE. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is 10 dB. Get Function: RFmxSpecAn_ACPGetNearIFOutputPowerOffset Set Function: RFmxSpecAn_ACPSetNearIFOutputPowerOffset |
Data Type: | float64 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeF64 RFmxSpecAn_GetAttributeF64 |
Description: | Specifies the offset by which to adjust the IF output power level for offset channels that are far from the carrier channel to improve the dynamic range. This value is expressed in dB. This attribute is used only if you set the RFMXSPECAN_ATTR_ACP_MEASUREMENT_METHOD attribute to RFMXSPECAN_VAL_ACP_MEASUREMENT_METHOD_DYNAMIC_RANGE and set the RFMXSPECAN_ATTR_ACP_IF_OUTPUT_POWER_OFFSET_AUTO attribute to RFMXSPECAN_VAL_ACP_IF_OUTPUT_POWER_OFFSET_AUTO_FALSE. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is 20 dB. Get Function: RFmxSpecAn_ACPGetFarIFOutputPowerOffset Set Function: RFmxSpecAn_ACPSetFarIFOutputPowerOffset |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies the FFT size when you set the RFMXSPECAN_ATTR_ACP_MEASUREMENT_METHOD attribute to RFMXSPECAN_VAL_ACP_MEASUREMENT_METHOD_SEQUENTIAL_FFT. The default value is 512. Get Function: RFmxSpecAn_ACPGetSequentialFFTSize Set Function: RFmxSpecAn_ACPSetSequentialFFTSize |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies whether the amplitude of the frequency bins, used in the measurement, is corrected for external attenuation at the RF center frequency, or at the individual frequency bins. Use the RFmxInstr_CfgExternalAttenuationTable function to configure the external attenuation table. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXSPECAN_VAL_ACP_AMPLITUDE_CORRECTION_TYPE_RF_CENTER_FREQUENCY. Get Function: RFmxSpecAn_ACPGetAmplitudeCorrectionType Set Function: RFmxSpecAn_ACPSetAmplitudeCorrectionType |
Values: |
RFMXSPECAN_VAL_ACP_AMPLITUDE_CORRECTION_TYPE_RF_CENTER_FREQUENCY (0) | All the frequency bins in the spectrum are compensated with a single external attenuation value that corresponds to the RF center frequency. |
---|---|
RFMXSPECAN_VAL_ACP_AMPLITUDE_CORRECTION_TYPE_SPECTRUM_FREQUENCY_BIN (1) | An individual frequency bin in the spectrum is compensated with the external attenuation value corresponding to that frequency. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies whether to enable the traces to be stored and retrieved after performing the ACP measurement. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXSPECAN_VAL_FALSE. Get Function: RFmxSpecAn_ACPGetAllTracesEnabled Set Function: RFmxSpecAn_ACPSetAllTracesEnabled |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies the maximum number of threads used for parallelism for adjacent channel power (ACP) measurement. The number of threads can range from 1 to the number of physical cores. The number of threads you set may not be used in calculations. The actual number of threads used depends on the problem size, system resources, data availability, and other considerations. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is 1. Get Function: RFmxSpecAn_ACPGetNumberOfAnalysisThreads Set Function: RFmxSpecAn_ACPSetNumberOfAnalysisThreads |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeF64 |
Description: | Returns the total integrated power, in dBm, of all the active carriers measured when you set the RFMXSPECAN_ATTR_ACP_POWER_UNITS attribute to RFMXSPECAN_VAL_ACP_POWER_UNITS_DBM. Returns the power spectral density, in dBm/Hz, based on the power in all the active carriers measured when you set the RFMXSPECAN_ATTR_ACP_POWER_UNITS attribute to RFMXSPECAN_VAL_ACP_POWER_UNITS_DBM_PER_HZ. You do not need to use a selector string to read this result for default signal and result instance. Refer to the Selector Strings topic for information about the string syntax for named signals and results. Get Function: RFmxSpecAn_ACPGetResultsTotalCarrierPower |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeF64 |
Description: | Returns the frequency bin spacing of the spectrum acquired by the measurement. This value is expressed in Hz. You do not need to use a selector string to read this result for default signal and result instance. Refer to the Selector Strings topic for information about the string syntax for named signals and results. Get Function: RFmxSpecAn_ACPGetResultsFrequencyResolution |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeF64 |
Description: | Returns the center frequency of the carrier relative to the Center Frequency attribute. This value is expressed in Hz. Use 'carrier(n)' as the selector string to read this result. Get Function: RFmxSpecAn_ACPGetResultsCarrierFrequency |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeF64 |
Description: | Returns the frequency range, over which the measurement integrates the carrier power. This value is expressed in Hz. Use 'carrier(n)' as the selector string to read this result. Get Function: RFmxSpecAn_ACPGetResultsCarrierIntegrationBandwidth |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeF64 |
Description: | Returns the measured carrier power. Use 'carrier(n)' as the selector string to read this result. The carrier power is reported in dBm when you set the RFMXSPECAN_ATTR_ACP_POWER_UNITS attribute to RFMXSPECAN_VAL_ACP_POWER_UNITS_DBM, and in dBm/Hz when you set the RFMXSPECAN_ATTR_ACP_POWER_UNITS attribute to RFMXSPECAN_VAL_ACP_POWER_UNITS_DBM_PER_HZ. Get Function: RFmxSpecAn_ACPGetResultsCarrierAbsolutePower |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeF64 |
Description: | Returns the carrier power measured relative to the total carrier power of all active carriers. This value is expressed in dB. Use 'carrier(n)' as the selector string to read this result. Get Function: RFmxSpecAn_ACPGetResultsCarrierTotalRelativePower |
Data Type: | int32 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeI32 |
Description: | Returns the index of the carrier used as a reference to define the center frequency of the lower (negative) offset channel. Lower offset channels are channels that are to the left of the carrier. Use 'offset(n)' as the selector string to read this result. Get Function: RFmxSpecAn_ACPGetResultsLowerOffsetFrequencyReferenceCarrier |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeF64 |
Description: | Returns the center frequency of the lower offset channel relative to the center frequency of the closest carrier. The offset frequency has a negative value. Use 'offset(n)' as the selector string to read this result. Get Function: RFmxSpecAn_ACPGetResultsLowerOffsetFrequency |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeF64 |
Description: | Returns the integration bandwidth used to measure the power in the lower offset channel. Use 'offset(n)' as the selector string to read this result. Get Function: RFmxSpecAn_ACPGetResultsLowerOffsetIntegrationBandwidth |
Data Type: | int32 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeI32 |
Description: | Returns the index of the carrier used as the power reference to measure the lower (negative) offset channel relative power. A value of -1 indicates that the total power of all active carriers is used as the reference power. The measurement uses the RFMXSPECAN_ATTR_ACP_OFFSET_POWER_REFERENCE_CARRIER attribute to set the power reference. Use 'offset(n)' as the selector string to read this result. Get Function: RFmxSpecAn_ACPGetResultsLowerOffsetPowerReferenceCarrier |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeF64 |
Description: | Returns the lower offset channel power. The offset channel power is reported in dBm when you set the RFMXSPECAN_ATTR_ACP_POWER_UNITS attribute to RFMXSPECAN_VAL_ACP_POWER_UNITS_DBM, and in dBm/Hz when you set the RFMXSPECAN_ATTR_ACP_POWER_UNITS attribute to RFMXSPECAN_VAL_ACP_POWER_UNITS_DBM_PER_HZ. Use 'offset(n)' as the selector string to read this result. Get Function: RFmxSpecAn_ACPGetResultsLowerOffsetAbsolutePower |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeF64 |
Description: | Returns the lower offset channel power measured relative to the integrated power of the power reference carrier. This value is expressed in dB. Use 'offset(n)' as the selector string to read this result. Get Function: RFmxSpecAn_ACPGetResultsLowerOffsetRelativePower |
Data Type: | int32 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeI32 |
Description: | Returns the index of the carrier used as a reference to define the center frequency of the upper (positive) offset channel. Upper offset channels are channels that are to the right of the carrier. Use 'offset(n)' as the selector string to read this result. Get Function: RFmxSpecAn_ACPGetResultsUpperOffsetFrequencyReferenceCarrier |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeF64 |
Description: | Returns the center frequency of the upper offset channel relative to the center frequency of the closest carrier. The offset frequency has a positive value. Use 'offset(n)' as the selector string to read this result. Get Function: RFmxSpecAn_ACPGetResultsUpperOffsetFrequency |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeF64 |
Description: | Returns the integration bandwidth used to measure the power in the upper offset channel. Use 'offset(n)' as the selector string to read this result. Get Function: RFmxSpecAn_ACPGetResultsUpperOffsetIntegrationBandwidth |
Data Type: | int32 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeI32 |
Description: | Returns the index of the carrier used as the power reference to measure the upper (positive) offset channel relative power. A value of -1 indicates that the total power of all active carriers is used as the reference power. The measurement uses the RFMXSPECAN_ATTR_ACP_OFFSET_POWER_REFERENCE_CARRIER attribute to set the power reference. Use 'offset(n)' as the selector string to read this result. Get Function: RFmxSpecAn_ACPGetResultsUpperOffsetPowerReferenceCarrier |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeF64 |
Description: | Returns the upper offset channel power. The offset channel power is reported in dBm when you set the RFMXSPECAN_ATTR_ACP_POWER_UNITS attribute to RFMXSPECAN_VAL_ACP_POWER_UNITS_DBM, and in dBm/Hz when you set the RFMXSPECAN_ATTR_ACP_POWER_UNITS attribute to RFMXSPECAN_VAL_ACP_POWER_UNITS_DBM_PER_HZ. Use 'offset(n)' as the selector string to read this result. Get Function: RFmxSpecAn_ACPGetResultsUpperOffsetAbsolutePower |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeF64 |
Description: | Returns the upper offset channel power measured relative to the integrated power of the power reference carrier. This value is expressed in dB. Use 'offset(n)' as the selector string to read this result. Get Function: RFmxSpecAn_ACPGetResultsUpperOffsetRelativePower |
Creating and Setting Up a gRPC Server
Session Utilities API Reference
gRPC API Differences From C API
Sharing Driver Sessions Between Clients
C API Docs
NI-DAQmx
- gRPC API Differences From C API
- Task Configuration And Control
- Channel Configuration And Creation
- Timing
- Triggering
- Read Functions
- Write Functions
- Export Hardware Signals
- Scale Configuration
- Internal Buffer Configuration
- Advanced Functions
- System Configuration
- Error Handling
- Buffer Attributes
- Calibration Info Attributes
- Channel Attributes
- Device Attributes
- Export Signal Attributes
- Persisted Channel Attributes
- Persisted Scale Attributes
- Persisted Task Attributes
- Physical Channel Attributes
- Read Attributes
- Scale Attributes
- System Attributes
- Task Attributes
- Timing Attributes
- Trigger Attributes
- Watchdog Attributes
- Write Attributes
NI-DCPOWER
- Setup Functions
- Configure Functions
- Measurement Functions
- Control Functions
- Trigger And Event
- Attribute Functions
- Query Functions
- Calibration Functions
- Utility Functions
- Supported Device
- Source Attributes
- Transient Attributes
- Voltage Attributes
- Current Attributes
- Pulse Voltage Attributes
- Pulse Current Attributes
- Cutoff Attributes
- Measurement Attributes
- Trigger Attributes Functions
- Event Attributes
- Advanced Attributes
- Inherent Ivi Attributes
- Supported Device Attributes
NI-DIGITAL PATTERN DRIVER
- Init And Close Functions
- Session Locking Functions
- Utility Functions
- Error Handling Functions
- Calibration Functions
- Attributes Functions
- Pin Map Functions
- Low Level Functions
- Low Level Action Functions
- Pin Control Functions
- Static IO Functions
- Clock Generator Functions
- Levels And Timing Functions
- TDR Functions
- PPMU Configuration Functions
- DC Voltage Functions
- DC Current Functions
- PPMU Action Functions
- Pattern Configuration Functions
- Pattern Action Functions
- History Ram Functions
- Source Memory Functions
- Capture Memory Functions
- Triggers And Events Functions
- Conditional Jump Trigger Functions
- Sequencer Flag Functions
- Sequencer Register Functions
- Match Fail Combination Functions
- Pattern Results Functions
- Sort Results Functions
- Frequency Measurement Functions
- IVI Inherent Attributes
- Specific Driver Information Attributes, Read Only
- Driver Setup Information Attributes
- Device Attributes
- Pin Control Attributes
- Level Configuration Attributes
- Trigger Configuration Attributes
- PPMU Attributes
- Patterns Attributes
- Pattern Opcode Event Attributes
- Timing Offset Attributes
- Keep Alive Attributes
- Frequency Measurement Attributes
- Clock Generator Attributes
- History RAM
- Synchronization Attributes
- TDR Endpoint Termination Attributes
NI-FGEN
- Setup Functions
- Configuration Functions
- Standard Output Functions
- Arbitrary Waveform Output Functions
- Arbitrary Sequence Output Functions
- Incremental Waveform Write Functions
- Configure Clock Functions
- Trigger And Syncronizations Functions
- 5404 Routing Functions
- Script Output Functions
- Configure Onboard Signal Processing Functions
- Configure Peer To Peer Functions
- Attribute Functions
- Waveform Control Functions
- Error Functions
- Output Attributes
- Arbitrary Waveform Attributes
- Data Transfer Attributes
- Onboard Signal Processing Attributes
- Peer To Peer Attributes
- Standard Function Attributes
- Clock Attributes
- Event Attributes
- Triggering Attributes
- Instrument Specific Attributes
- Inherent IVI Attributes
- 5401 5411 5431
NI-RFmx Bluetooth
- gRPC API Differences From C API
- General Functions
- Configuration Functions
- Set And Get Attribute Functions
- Fetch Results Functions
- Utility Functions
- Build String Functions
- Advanced Functions
- General Attributes
- Trigger Attributes
- Packet Attributes
- Auto Detect Signal Attributes
- Modacc Attributes
- ACP Attributes
- Twenty dB Attributes
- Frequency Range Attributes
- TXP Attributes
- Advanced Attributes
NI-RFmx NR
- gRPC API Differences From C API
- General Functions
- Configuration Functions
- Set And Get Attributes Functions
- Fetch Results Functions
- Utility Functions
- Build String Functions
- Advanced Functions
- General Attributes
- Trigger Attributes
- Signal Detection Attributes
- Component Carrier Attributes
- List Attributes
- Modacc Attributes
- ACP Attributes
- CHP Attributes
- OBW Attributes
- SEM Attributes
- TXP Attributes
- Pvt Attributes
- Advanced Attributes
NI-RFmx LTE
- gRPC API Differences From C API
- General Functions
- Configuration Functions
- Ch Configuration Functions
- NB IoT Configuration Functions
- ModAcc Configuration Functions
- ACP Configuration Functions
- CHP Configuration Functions
- OBW Configuration Functions
- SEM Configuration Functions
- PVT Configuration Functions
- SlotPhase Configuration Functions
- SlotPower Configuration Functions
- Set And Get Attribute Functions
- ModAcc Fetch Functions
- ACP Fetch Functions
- CHP Fetch Functions
- OBW Fetch Functions
- SEM Fetch Functions
- PVT Fetch Functions
- SlotPhase Fetch Functions
- SlotPower Fetch Functions
- Utility Functions
- Build String Functions
- Advanced Functions
- General Attributes
- Trigger Attributes
- Component Carrier Attributes
- ModAcc Attributes
- ACP Attributes
- CHP Attributes
- OBW Attributes
- SEM Attributes
- PVT Attributes
- SlotPhase Attributes
- SlotPower Attributes
- Advanced Attributes
NI-RFmx SpecAn
- gRPC API Differences From C API
- General Functions
- Configuration Functions
- Set And Get Attribute Functions
- Read Functions
- Fetch Functions
- Utility Functions
- Marker Functions
- Build String Functions
- Advanced Functions
- General Attributes
- Trigger Attributes
- ACP Attributes
- Cdf Attributes
- CHP Attributes
- Fcnt Attributes
- Harm Attributes
- OBW Attributes
- SEM Attributes
- Spectrum Attributes
- Spur Attributes
- TXP Attributes
- AMPM Attributes
- Dpd Attributes
- IQ Attributes
- IM Attributes
- NF Attributes
- Phasenoise Attributes
- PAVT Attributes
- Advanced Attributes
NI-RFmx WLAN
- gRPC API Differences From C API
- General Functions
- Configuration Functions
- Set And Get Attribute Functions
- Fetch DSSS ModAcc Functions
- Fetch OFDM ModAcc Functions
- Fetch SEM Functions
- Fetch TXP Functions
- Fetch PowerRamp Functions
- Utility Functions
- Build String Functions
- Advanced Functions
- General Attributes
- Trigger Attributes
- OFDM Attributes
- Auto Detect Signal Attributes
- DSSS ModAcc Attributes
- OFDM ModAcc Attributes
- SEM Attributes
- TXP Attributes
- PowerRamp Attributes
- Advanced Attributes
NI-RFSA
- General Functions
- Configuration Functions
- Acquisition Functions
- Utility Functions
- Calibration Functions
- General Attributes
- Vertical Attributes
- Signal Path Attributes
- Acquisition Attributes
- Acquisition Attributes
- Triggers Attributes
- Events Attributes
- Device Characteristics Attributes
- Peer To Peer Streaming Attributes
- Configuration List Attributes
- Inherent IVI Properties Attributes
- De-embedding Attributes
- Self Calibration Attributes
- Factory Calibration Attributes
- External Alignment Attributes
- Device Specific Attributes
NI-RFSG
- General Functions
- Generation Configuration
- Utility Functions
- Calibration Functions
- Arb Attributes
- Clock Attributes
- Configuration List Attributes
- De-embedding Attributes
- Device Characteristics Attributes
- Device Specific Attributes
- Events Attributes
- External Calibration Attributes
- Inherent IVI Attributes Attributes
- IQ Impairment Attributes
- Load Configurations Attributes
- Modulation Attributes
- Obsolete Attributes
- Peer To Peer Attributes
- RF Attributes
- Self Calibration Attributes
- Triggers Attributes
NI-SCOPE
- Setup Functions
- Configure Functions
- Attribute Functions
- Acquisition Functions
- Measurement Functions
- Calibrate Functions
- Utility Funcitons
- Error Handling Functions
- IVI Compliance Or Obsolete Functions
- Vertical Attributes
- Horizontal Attributes
- Trigger Attributes
- Clocking Attributes
- Synchronization Attributes
- Acquisition Attributes
- Waveform Measurements Attributes
- Onboard Signal Processing Attributes
- Peer To Peer Streaming Attributes
- Device Attributes
- IVI Or Obsolete Attributes
- Instrument Capabilities Attributes
- If Digitizer Attributes
NI-XNET
- gRPC API differences from C APIs
- General Functions
- Cluster Properties
- Database Properties
- Device Properties
- ECU Properties
- Frame Properties
- Interface Properties
- LIN Schedule Entry Properties
- LIN Schedule Properties
- PDU Properties
- Session Ethernet Properties
- Session Frame Properties
- Session Interface Properties
- Session Properties
- Session SAE J1939 Properties
- Signal Properties
- Subframe Properties
- System Properties
- IP-Stack Functions
- Socket Options
- Socket Functions