Notifications
You must be signed in to change notification settings - Fork 52
NI RFmx NR Modacc Attributes
Ryan Eckenrode edited this page Mar 1, 2022
·
3 revisions
- RFMXNR_ATTR_MODACC_MEASUREMENT_ENABLED
- RFMXNR_ATTR_MODACC_MULTICARRIER_FILTER_ENABLED
- RFMXNR_ATTR_MODACC_SYNCHRONIZATION_MODE
- RFMXNR_ATTR_MODACC_MEASUREMENT_LENGTH_UNIT
- RFMXNR_ATTR_MODACC_MEASUREMENT_OFFSET
- RFMXNR_ATTR_MODACC_MEASUREMENT_LENGTH
-
IQ Impairments
- RFMXNR_ATTR_MODACC_IQ_IMPAIRMENTS_MODEL
- RFMXNR_ATTR_MODACC_IQ_MISMATCH_ESTIMATION_ENABLED
- RFMXNR_ATTR_MODACC_IQ_GAIN_IMBALANCE_CORRECTION_ENABLED
- RFMXNR_ATTR_MODACC_IQ_QUADRATURE_ERROR_CORRECTION_ENABLED
- RFMXNR_ATTR_MODACC_IQ_TIMING_SKEW_CORRECTION_ENABLED
- RFMXNR_ATTR_MODACC_IQ_IMPAIRMENTS_PER_SUBCARRIER_ENABLED
- RFMXNR_ATTR_MODACC_EVM_REFERENCE_DATA_SYMBOLS_MODE
- RFMXNR_ATTR_MODACC_SPECTRUM_INVERTED
- RFMXNR_ATTR_MODACC_CHANNEL_ESTIMATION_TYPE
- RFMXNR_ATTR_MODACC_PHASE_TRACKING_ENABLED
- RFMXNR_ATTR_MODACC_TIMING_TRACKING_ENABLED
- RFMXNR_ATTR_MODACC_EVM_UNIT
- RFMXNR_ATTR_MODACC_FFT_WINDOW_TYPE
- RFMXNR_ATTR_MODACC_FFT_WINDOW_OFFSET
- RFMXNR_ATTR_MODACC_FFT_WINDOW_LENGTH
- RFMXNR_ATTR_MODACC_DC_SUBCARRIER_REMOVAL_ENABLED
- RFMXNR_ATTR_MODACC_COMMON_CLOCK_SOURCE_ENABLED
- RFMXNR_ATTR_MODACC_SPECTRAL_FLATNESS_CONDITION
- Noise Compensation
- RFMXNR_ATTR_MODACC_MEASUREMENT_MODE
- Averaging
- RFMXNR_ATTR_MODACC_ALL_TRACES_ENABLED
- RFMXNR_ATTR_MODACC_NUMBER_OF_ANALYSIS_THREADS
- Auto Level
- RFMXNR_ATTR_MODACC_ALL_TRACES_ENABLED
- RFMXNR_ATTR_MODACC_NUMBER_OF_ANALYSIS_THREADS
-
Results
- RFMXNR_ATTR_MODACC_RESULTS_COMPOSITE_RMS_EVM_MEAN
- RFMXNR_ATTR_MODACC_RESULTS_COMPOSITE_PEAK_EVM_MAXIMUM
- RFMXNR_ATTR_MODACC_RESULTS_COMPOSITE_PEAK_EVM_BWP_INDEX
- RFMXNR_ATTR_MODACC_RESULTS_COMPOSITE_PEAK_EVM_SLOT_INDEX
- RFMXNR_ATTR_MODACC_RESULTS_COMPOSITE_PEAK_EVM_SYMBOL_INDEX
- RFMXNR_ATTR_MODACC_RESULTS_COMPOSITE_PEAK_EVM_SUBCARRIER_INDEX
- RFMXNR_ATTR_MODACC_RESULTS_COMPOSITE_RMS_MAGNITUDE_ERROR_MEAN
- RFMXNR_ATTR_MODACC_RESULTS_COMPOSITE_PEAK_MAGNITUDE_ERROR_MAXIMUM
- RFMXNR_ATTR_MODACC_RESULTS_COMPOSITE_RMS_PHASE_ERROR_MEAN
- RFMXNR_ATTR_MODACC_RESULTS_COMPOSITE_PEAK_PHASE_ERROR_MAXIMUM
- RFMXNR_ATTR_MODACC_RESULTS_SCH_SYMBOL_POWER_MEAN
-
Pusch
- RFMXNR_ATTR_MODACC_RESULTS_PUSCH_DATA_RMS_EVM_MEAN
- RFMXNR_ATTR_MODACC_RESULTS_PUSCH_DATA_PEAK_EVM_MAXIMUM
- RFMXNR_ATTR_MODACC_RESULTS_PUSCH_DMRS_RMS_EVM_MEAN
- RFMXNR_ATTR_MODACC_RESULTS_PUSCH_DMRS_PEAK_EVM_MAXIMUM
- RFMXNR_ATTR_MODACC_RESULTS_PUSCH_PTRS_RMS_EVM_MEAN
- RFMXNR_ATTR_MODACC_RESULTS_PUSCH_PTRS_PEAK_EVM_MAXIMUM
-
Pdsch
- RFMXNR_ATTR_MODACC_RESULTS_PDSCH_QPSK_RMS_EVM_MEAN
- RFMXNR_ATTR_MODACC_RESULTS_PDSCH_16QAM_RMS_EVM_MEAN
- RFMXNR_ATTR_MODACC_RESULTS_PDSCH_64QAM_RMS_EVM_MEAN
- RFMXNR_ATTR_MODACC_RESULTS_PDSCH_256QAM_RMS_EVM_MEAN
- RFMXNR_ATTR_MODACC_RESULTS_PDSCH_1024QAM_RMS_EVM_MEAN
- RFMXNR_ATTR_MODACC_RESULTS_PDSCH_8PSK_RMS_EVM_MEAN
- RFMXNR_ATTR_MODACC_RESULTS_PDSCH_DATA_RMS_EVM_MEAN
- RFMXNR_ATTR_MODACC_RESULTS_PDSCH_DATA_PEAK_EVM_MAXIMUM
- RFMXNR_ATTR_MODACC_RESULTS_PDSCH_DMRS_RMS_EVM_MEAN
- RFMXNR_ATTR_MODACC_RESULTS_PDSCH_DMRS_PEAK_EVM_MAXIMUM
- RFMXNR_ATTR_MODACC_RESULTS_PDSCH_PTRS_RMS_EVM_MEAN
- RFMXNR_ATTR_MODACC_RESULTS_PDSCH_PTRS_PEAK_EVM_MAXIMUM
- RFMXNR_ATTR_MODACC_RESULTS_IN_BAND_EMISSION_MARGIN
- RFMXNR_ATTR_MODACC_RESULTS_SUBBLOCK_IN_BAND_EMISSION_MARGIN
-
Spectral Flatness
- RFMXNR_ATTR_MODACC_RESULTS_SPECTRAL_FLATNESS_RANGE1_MAXIMUM_TO_RANGE1_MINIMUM
- RFMXNR_ATTR_MODACC_RESULTS_SPECTRAL_FLATNESS_RANGE2_MAXIMUM_TO_RANGE2_MINIMUM
- RFMXNR_ATTR_MODACC_RESULTS_SPECTRAL_FLATNESS_RANGE1_MAXIMUM_TO_RANGE2_MINIMUM
- RFMXNR_ATTR_MODACC_RESULTS_SPECTRAL_FLATNESS_RANGE2_MAXIMUM_TO_RANGE1_MINIMUM
- RFMXNR_ATTR_MODACC_RESULTS_COMPONENT_CARRIER_TIME_OFFSET_MEAN
- RFMXNR_ATTR_MODACC_RESULTS_COMPONENT_CARRIER_FREQUENCY_ERROR_MEAN
- RFMXNR_ATTR_MODACC_RESULTS_COMPONENT_CARRIER_SYMBOL_CLOCK_ERROR_MEAN
- RFMXNR_ATTR_MODACC_RESULTS_COMPONENT_CARRIER_IQ_ORIGIN_OFFSET_MEAN
- RFMXNR_ATTR_MODACC_RESULTS_COMPONENT_CARRIER_IQ_GAIN_IMBALANCE_MEAN
- RFMXNR_ATTR_MODACC_RESULTS_COMPONENT_CARRIER_QUADRATURE_ERROR_MEAN
- RFMXNR_ATTR_MODACC_RESULTS_COMPONENT_CARRIER_IQ_TIMING_SKEW_MEAN
- RFMXNR_ATTR_MODACC_RESULTS_SUBBLOCK_LO_COMPONENT_CARRIER_INDEX
- RFMXNR_ATTR_MODACC_RESULTS_SUBBLOCK_LO_SUBCARRIER_INDEX
- RFMXNR_ATTR_MODACC_RESULTS_SUBBLOCK_IQ_ORIGIN_OFFSET_MEAN
- RFMXNR_ATTR_MODACC_RESULTS_NOISE_COMPENSATION_APPLIED
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxNR_SetAttributeI32 RFmxNR_GetAttributeI32 |
Description: | Specifies whether to enable the ModAcc measurement. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXNR_VAL_FALSE. Get Function: RFmxNR_ModAccGetMeasurementEnabled Set Function: RFmxNR_ModAccSetMeasurementEnabled |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxNR_SetAttributeI32 RFmxNR_GetAttributeI32 |
Description: | Specifies whether to use the filter in single carrier configurations to minimize leakage into the carrier. Measurement ignores this attribute, if number of carriers is set to more than 1 or if you set the RFMXNR_ATTR_ACQUISITION_BANDWIDTH_OPTIMIZATION_ENABLED attribute to RFMXNR_VAL_ACQUISITION_BANDWIDTH_OPTIMIZATION_ENABLED_FALSE, where in the multi carrier filter will always be used. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXNR_VAL_MODACC_MULTICARRIER_FILTER_ENABLED_FALSE. Get Function: RFmxNR_ModAccGetMulticarrierFilterEnabled Set Function: RFmxNR_ModAccSetMulticarrierFilterEnabled |
Values: |
RFMXNR_VAL_MODACC_MULTICARRIER_FILTER_ENABLED_FALSE (0) | Measurement doesn't use the filter. |
---|---|
RFMXNR_VAL_MODACC_MULTICARRIER_FILTER_ENABLED_TRUE (1) | Measurement filters out unwanted emissions. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxNR_SetAttributeI32 RFmxNR_GetAttributeI32 |
Description: | Specifies whether the measurement is performed from slot or frame boundary. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXNR_VAL_MODACC_SYNCHRONIZATION_MODE_SLOT. Get Function: RFmxNR_ModAccGetSynchronizationMode Set Function: RFmxNR_ModAccSetSynchronizationMode |
Values: |
RFMXNR_VAL_MODACC_SYNCHRONIZATION_MODE_SLOT (1) | The measurement is performed over the RFMXNR_ATTR_MODACC_MEASUREMENT_LENGTH starting at the RFMXNR_ATTR_MODACC_MEASUREMENT_OFFSET from the slot boundary. If you set the RFMXNR_ATTR_TRIGGER_TYPE attribute to RFMXNR_VAL_TRIGGER_TYPE_DIGITAL_EDGE, the measurement expects the digital trigger at the slot boundary. |
---|---|
RFMXNR_VAL_MODACC_SYNCHRONIZATION_MODE_FRAME (5) | The measurement is performed over the RFMXNR_ATTR_MODACC_MEASUREMENT_LENGTH starting at RFMXNR_ATTR_MODACC_MEASUREMENT_OFFSET from the frame boundary. If you set the RFMXNR_ATTR_TRIGGER_TYPE attribute to Digital Edge, the measurement expects the digital trigger at the frame boundary. |
RFMXNR_VAL_MODACC_SYNCHRONIZATION_MODE_SSB_START_FRAME (7) | The measurement is performed over the RFMXNR_ATTR_MODACC_MEASUREMENT_LENGTH starting at RFMXNR_ATTR_MODACC_MEASUREMENT_OFFSET from the boundary of the frame having SSB. If you set the RFMXNR_ATTR_TRIGGER_TYPE attribute to Digital Edge, the measurement expects the digital trigger from the boundary of the frame having SSB. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxNR_SetAttributeI32 RFmxNR_GetAttributeI32 |
Description: | Specifies the units in which measurement offset and measurement length are specified. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXNR_VAL_MODACC_MEASUREMENT_LENGTH_UNIT_SLOT. Get Function: RFmxNR_ModAccGetMeasurementLengthUnit Set Function: RFmxNR_ModAccSetMeasurementLengthUnit |
Values: |
RFMXNR_VAL_MODACC_MEASUREMENT_LENGTH_UNIT_SLOT (1) | Measurement offset and measurement length are specified in units of slots. |
---|---|
RFMXNR_VAL_MODACC_MEASUREMENT_LENGTH_UNIT_SUBFRAME (3) | Measurement offset and measurement length are specified in units of subframes. |
RFMXNR_VAL_MODACC_MEASUREMENT_LENGTH_UNIT_TIME (6) | Measurement offset and measurement length are specified in seconds. Specify the measurement offset and length in multiples of 1 ms * (15 kHz/minimum subcarrier spacing of all carriers). All slots within this notional time duration are analysed. |
Data Type: | float64 |
---|---|
Access: | read/write |
Functions: | RFmxNR_SetAttributeF64 RFmxNR_GetAttributeF64 |
Description: | Specifies the measurement offset to skip from the synchronization boundary. The synchronization boundary is specified by the RFMXNR_ATTR_MODACC_SYNCHRONIZATION_MODE attribute. The unit for this is specified by ModAcc Measurement Length Unit. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is 0. Get Function: RFmxNR_ModAccGetMeasurementOffset Set Function: RFmxNR_ModAccSetMeasurementOffset |
Data Type: | float64 |
---|---|
Access: | read/write |
Functions: | RFmxNR_SetAttributeF64 RFmxNR_GetAttributeF64 |
Description: | Specifies the measurement length in units specified by Measurement Length Unit attribute. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is 1. Get Function: RFmxNR_ModAccGetMeasurementLength Set Function: RFmxNR_ModAccSetMeasurementLength |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxNR_SetAttributeI32 RFmxNR_GetAttributeI32 |
Description: | Specifies the I/Q impairments model used by the measurement for estimating I/Q impairments. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXNR_VAL_MODACC_IQ_IMPAIRMENTS_MODEL_TX. Get Function: RFmxNR_ModAccGetIQImpairmentsModel Set Function: RFmxNR_ModAccSetIQImpairmentsModel |
Values: |
RFMXNR_VAL_MODACC_IQ_IMPAIRMENTS_MODEL_TX (0) | The measurement assumes that the I/Q impairments are introduced by a transmit DUT. |
---|---|
RFMXNR_VAL_MODACC_IQ_IMPAIRMENTS_MODEL_RX (1) | The measurement assumes that the I/Q impairments are introduced by a receive DUT. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxNR_SetAttributeI32 RFmxNR_GetAttributeI32 |
Description: | Specifies whether to estimate the IQ impairments such as IQ gain imbalance and quadrature skew. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXNR_VAL_MODACC_IQ_MISMATCH_ESTIMATION_ENABLED_TRUE. Get Function: RFmxNR_ModAccGetIQMismatchEstimationEnabled Set Function: RFmxNR_ModAccSetIQMismatchEstimationEnabled |
Values: |
RFMXNR_VAL_MODACC_IQ_MISMATCH_ESTIMATION_ENABLED_FALSE (0) | IQ Impairments estimation is disabled. |
---|---|
RFMXNR_VAL_MODACC_IQ_MISMATCH_ESTIMATION_ENABLED_TRUE (1) | IQ Impairments estimation is enabled. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxNR_SetAttributeI32 RFmxNR_GetAttributeI32 |
Description: | Specifies whether to enable IQ gain imbalance correction. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXNR_VAL_MODACC_IQ_GAIN_IMBALANCE_CORRECTION_ENABLED_FALSE. Get Function: RFmxNR_ModAccGetIQGainImbalanceCorrectionEnabled Set Function: RFmxNR_ModAccSetIQGainImbalanceCorrectionEnabled |
Values: |
RFMXNR_VAL_MODACC_IQ_GAIN_IMBALANCE_CORRECTION_ENABLED_FALSE (0) | IQ gain imbalance correction is disabled. |
---|---|
RFMXNR_VAL_MODACC_IQ_GAIN_IMBALANCE_CORRECTION_ENABLED_TRUE (1) | IQ gain imbalance correction is enabled. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxNR_SetAttributeI32 RFmxNR_GetAttributeI32 |
Description: | Specifies whether to enable IQ quadrature error correction. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXNR_VAL_MODACC_IQ_QUADRATURE_ERROR_CORRECTION_ENABLED_FALSE. Get Function: RFmxNR_ModAccGetIQQuadratureErrorCorrectionEnabled Set Function: RFmxNR_ModAccSetIQQuadratureErrorCorrectionEnabled |
Values: |
RFMXNR_VAL_MODACC_IQ_QUADRATURE_ERROR_CORRECTION_ENABLED_FALSE (0) | IQ quadrature error correction is disabled. |
---|---|
RFMXNR_VAL_MODACC_IQ_QUADRATURE_ERROR_CORRECTION_ENABLED_TRUE (1) | IQ quadrature error correction is enabled. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxNR_SetAttributeI32 RFmxNR_GetAttributeI32 |
Description: | Specifies whether to enable IQ timing skew correction. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXNR_VAL_MODACC_IQ_TIMING_SKEW_CORRECTION_ENABLED_FALSE. Get Function: RFmxNR_ModAccGetIQTimingSkewCorrectionEnabled Set Function: RFmxNR_ModAccSetIQTimingSkewCorrectionEnabled |
Values: |
RFMXNR_VAL_MODACC_IQ_TIMING_SKEW_CORRECTION_ENABLED_FALSE (0) | IQ timing skew correction is disabled. |
---|---|
RFMXNR_VAL_MODACC_IQ_TIMING_SKEW_CORRECTION_ENABLED_TRUE (1) | IQ timing skew correction is enabled. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxNR_SetAttributeI32 RFmxNR_GetAttributeI32 |
Description: | Specifies whether to return I/Q impairments independently for each subcarrier. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXNR_VAL_MODACC_IQ_IMPAIRMENTS_PER_SUBCARRIER_ENABLED_FALSE. Get Function: RFmxNR_ModAccGetIQImpairmentsPerSubcarrierEnabled Set Function: RFmxNR_ModAccSetIQImpairmentsPerSubcarrierEnabled |
Values: |
RFMXNR_VAL_MODACC_IQ_IMPAIRMENTS_PER_SUBCARRIER_ENABLED_FALSE (0) | Indicates that the independent estimation of I/Q impairments for each subcarrier is disabled. |
---|---|
RFMXNR_VAL_MODACC_IQ_IMPAIRMENTS_PER_SUBCARRIER_ENABLED_TRUE (1) | Indicates that the independent estimation of I/Q impairments for each subcarrier is enabled. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxNR_SetAttributeI32 RFmxNR_GetAttributeI32 |
Description: | Specifies whether to either use a reference waveform or an acquired waveform to create reference data symbols for EVM computation. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXNR_VAL_MODACC_EVM_REFERENCE_DATA_SYMBOLS_MODE_ACQUIRED_WAVEFORM. Get Function: RFmxNR_ModAccGetEVMReferenceDataSymbolsMode Set Function: RFmxNR_ModAccSetEVMReferenceDataSymbolsMode |
Values: |
RFMXNR_VAL_MODACC_EVM_REFERENCE_DATA_SYMBOLS_MODE_ACQUIRED_WAVEFORM (0) | Indicates that reference data symbols for EVM computation are created using the acquired waveform. |
---|---|
RFMXNR_VAL_MODACC_EVM_REFERENCE_DATA_SYMBOLS_MODE_REFERENCE_WAVEFORM (1) | Indicates that reference data symbols for EVM computation are created using the reference waveform. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxNR_SetAttributeI32 RFmxNR_GetAttributeI32 |
Description: | Specifies whether the spectrum of the signal being measured is inverted. This happens when I and Q component of the baseband complex signal is swapped. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXNR_VAL_MODACC_SPECTRUM_INVERTED_FALSE. Get Function: RFmxNR_ModAccGetSpectrumInverted Set Function: RFmxNR_ModAccSetSpectrumInverted |
Values: |
RFMXNR_VAL_MODACC_SPECTRUM_INVERTED_FALSE (0) | The signal being measured is not inverted. |
---|---|
RFMXNR_VAL_MODACC_SPECTRUM_INVERTED_TRUE (1) | The signal being measured is inverted and measurement will correct it by swapping the I and Q components. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxNR_SetAttributeI32 RFmxNR_GetAttributeI32 |
Description: | Specifies the method used for channel estimation. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is Reference+Data. Get Function: RFmxNR_ModAccGetChannelEstimationType Set Function: RFmxNR_ModAccSetChannelEstimationType |
Values: |
RFMXNR_VAL_MODACC_CHANNEL_ESTIMATION_TYPE_REFERENCE (0) | Only demodulation reference (DMRS) symbol is used to calculate channel coefficients. |
---|---|
RFMXNR_VAL_MODACC_CHANNEL_ESTIMATION_TYPE_REFERENCE_AND_DATA (1) | Both demodulation reference (DMRS) and data symbols are used to calculate channel coefficients. This method is as per definition of 3GPP NR specification. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxNR_SetAttributeI32 RFmxNR_GetAttributeI32 |
Description: | Specifies whether phase tracking is enabled. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXNR_VAL_MODACC_PHASE_TRACKING_ENABLED_TRUE. Get Function: RFmxNR_ModAccGetPhaseTrackingEnabled Set Function: RFmxNR_ModAccSetPhaseTrackingEnabled |
Values: |
RFMXNR_VAL_MODACC_PHASE_TRACKING_ENABLED_FALSE (0) | The phase tracking is disabled. |
---|---|
RFMXNR_VAL_MODACC_PHASE_TRACKING_ENABLED_TRUE (1) | The phase tracking is done per symbol. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxNR_SetAttributeI32 RFmxNR_GetAttributeI32 |
Description: | Specifies whether timing tracking is enabled. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXNR_VAL_MODACC_TIMING_TRACKING_ENABLED_TRUE. Get Function: RFmxNR_ModAccGetTimingTrackingEnabled Set Function: RFmxNR_ModAccSetTimingTrackingEnabled |
Values: |
RFMXNR_VAL_MODACC_TIMING_TRACKING_ENABLED_FALSE (0) | The time tracking is disabled. |
---|---|
RFMXNR_VAL_MODACC_TIMING_TRACKING_ENABLED_TRUE (1) | The time tracking is done per symbol. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxNR_SetAttributeI32 RFmxNR_GetAttributeI32 |
Description: | Specifies the units of the EVM results. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXNR_VAL_MODACC_EVM_UNIT_PERCENTAGE. Get Function: RFmxNR_ModAccGetEVMUnit Set Function: RFmxNR_ModAccSetEVMUnit |
Values: |
RFMXNR_VAL_MODACC_EVM_UNIT_PERCENTAGE (0) | The EVM is reported as a percentage. |
---|---|
RFMXNR_VAL_MODACC_EVM_UNIT_DB (1) | The EVM is reported in dB. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxNR_SetAttributeI32 RFmxNR_GetAttributeI32 |
Description: | Specifies the FFT window type used for EVM calculation. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXNR_VAL_MODACC_FFT_WINDOW_TYPE_CUSTOM. Get Function: RFmxNR_ModAccGetFFTWindowType Set Function: RFmxNR_ModAccSetFFTWindowType |
Values: |
RFMXNR_VAL_MODACC_FFT_WINDOW_TYPE_3GPP (0) | The maximum EVM between the start window position and the end window position is returned according to the 3GPP specification. The FFT window positions are specified by the attribute. |
---|---|
RFMXNR_VAL_MODACC_FFT_WINDOW_TYPE_CUSTOM (1) | Only one FFT window position is used for the EVM calculation. FFT window position is specified by RFMXNR_ATTR_MODACC_FFT_WINDOW_OFFSET attribute. |
Data Type: | float64 |
---|---|
Access: | read/write |
Functions: | RFmxNR_SetAttributeF64 RFmxNR_GetAttributeF64 |
Description: | Specifies the position of the FFT window used to calculate the EVM when RFMXNR_ATTR_MODACC_FFT_WINDOW_TYPE attribute is set to RFMXNR_VAL_MODACC_FFT_WINDOW_TYPE_CUSTOM. The offset is expressed as a percentage of the cyclic prefix length. If you set this attribute to 0, the EVM window starts at the end of cyclic prefix. If you set this attribute to 100, the EVM window starts at the beginning of cyclic prefix. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is 50. Valid values are 0 to 100, inclusive. Get Function: RFmxNR_ModAccGetFFTWindowOffset Set Function: RFmxNR_ModAccSetFFTWindowOffset |
Data Type: | float64 |
---|---|
Access: | read/write |
Functions: | RFmxNR_SetAttributeF64 RFmxNR_GetAttributeF64 |
Description: | Specifies the FFT window length (W). This value is expressed as a percentage of the cyclic prefix length. This attribute is used when you set the RFMXNR_ATTR_MODACC_FFT_WINDOW_TYPE attribute to RFMXNR_VAL_MODACC_FFT_WINDOW_TYPE_3GPP, where it is needed to calculate the EVM using two different FFT window positions, Delta_C-W/2, and Delta_C+W/2. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is -1. Valid values range from -1 to 100, inclusive. When this attribute is set to -1, the measurement automatically sets the value of this attribute to the recommended value as specified in the Annexe F.5 of 3GPP TS 38.101-2 specification for uplink and Annexe B.5.2 and C.5.2 of 3GPP TS 38.104 specification for downlink. Get Function: RFmxNR_ModAccGetFFTWindowLength Set Function: RFmxNR_ModAccSetFFTWindowLength |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxNR_SetAttributeI32 RFmxNR_GetAttributeI32 |
Description: | Specifies whether the DC subcarrier is removed from the EVM results. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXNR_VAL_MODACC_DC_SUBCARRIER_REMOVAL_ENABLED_TRUE. Get Function: RFmxNR_ModAccGetDCSubcarrierRemovalEnabled Set Function: RFmxNR_ModAccSetDCSubcarrierRemovalEnabled |
Values: |
RFMXNR_VAL_MODACC_DC_SUBCARRIER_REMOVAL_ENABLED_FALSE (0) | The DC subcarrier is present in the EVM results. |
---|---|
RFMXNR_VAL_MODACC_DC_SUBCARRIER_REMOVAL_ENABLED_TRUE (1) | The DC subcarrier is removed from the EVM results. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxNR_SetAttributeI32 RFmxNR_GetAttributeI32 |
Description: | Specifies whether same reference clock is used for local oscillator and digital-to-analog converter. When same reference clock is used the Carrier Frequency Offset is proportional to Sample Clock Error. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXNR_VAL_MODACC_COMMON_CLOCK_SOURCE_ENABLED_TRUE. Get Function: RFmxNR_ModAccGetCommonClockSourceEnabled Set Function: RFmxNR_ModAccSetCommonClockSourceEnabled |
Values: |
RFMXNR_VAL_MODACC_COMMON_CLOCK_SOURCE_ENABLED_FALSE (0) | The Sample Clock error is estimated independently. |
---|---|
RFMXNR_VAL_MODACC_COMMON_CLOCK_SOURCE_ENABLED_TRUE (1) | The Sample Clock error is estimated from carrier frequency offset. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxNR_SetAttributeI32 RFmxNR_GetAttributeI32 |
Description: | Specifies the test condition for Spectral Flatness measurement. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXNR_VAL_MODACC_SPECTRAL_FLATNESS_CONDITION_NORMAL. Get Function: RFmxNR_ModAccGetSpectralFlatnessCondition Set Function: RFmxNR_ModAccSetSpectralFlatnessCondition |
Values: |
RFMXNR_VAL_MODACC_SPECTRAL_FLATNESS_CONDITION_NORMAL (0) | Frequency range and maximum ripple defined in the section 6.4.2.4.1, Table 6.4.2.4.1-1 of 3GPP 38.101-1 and section 6.4.2.4.1, Table 6.4.2.4.1-1 of 3GPP 38.101-2 are used. |
---|---|
RFMXNR_VAL_MODACC_SPECTRAL_FLATNESS_CONDITION_EXTREME (1) | Frequency range and maximum ripple defined in the section 6.4.2.4.1, Table 6.4.2.4.1-2 of 3GPP 38.101-1 and section 6.4.2.4.1, Table 6.4.2.4.1-2 of 3GPP 38.101-2 are used. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxNR_SetAttributeI32 RFmxNR_GetAttributeI32 |
Description: | Specifies whether the contribution of the instrument noise is compensated for EVM computation. You must measure the noise floor before applying the noise compensation. The instrument noise floor is measured for the RF path used by the ModAcc measurement and cached for future use. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. Supported devices are NI 5831 and NI 5840/41. The default value is RFMXNR_VAL_MODACC_NOISE_COMPENSATION_ENABLED_FALSE. Get Function: RFmxNR_ModAccGetNoiseCompensationEnabled Set Function: RFmxNR_ModAccSetNoiseCompensationEnabled |
Values: |
RFMXNR_VAL_MODACC_NOISE_COMPENSATION_ENABLED_FALSE (0) | Noise compensation is disabled for the measurement. |
---|---|
RFMXNR_VAL_MODACC_NOISE_COMPENSATION_ENABLED_TRUE (1) | Noise compensation is enabled for the measurement. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxNR_SetAttributeI32 RFmxNR_GetAttributeI32 |
Description: | Specifies whether the measurement checks if any high power signal is present at the RFIn port of the instrument while performing noise floor calibration. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXNR_VAL_MODACC_NOISE_COMPENSATION_INPUT_POWER_CHECK_ENABLED_TRUE. Get Function: RFmxNR_ModAccGetNoiseCompensationInputPowerCheckEnabled Set Function: RFmxNR_ModAccSetNoiseCompensationInputPowerCheckEnabled |
Values: |
RFMXNR_VAL_MODACC_NOISE_COMPENSATION_INPUT_POWER_CHECK_ENABLED_FALSE (0) | Disables the input power check at the RFIn port of the signal analyzer. |
---|---|
RFMXNR_VAL_MODACC_NOISE_COMPENSATION_INPUT_POWER_CHECK_ENABLED_TRUE (1) | Enables the input power check at the RFIn port of the signal analyzer. |
Data Type: | float64 |
---|---|
Access: | read/write |
Functions: | RFmxNR_SetAttributeF64 RFmxNR_GetAttributeF64 |
Description: | Specifies the coercion limit for the reference for noise compensation. When you set RFMXNR_ATTR_MODACC_MEASUREMENT_MODE attribute to RFMXNR_VAL_MODACC_MEASUREMENT_MODE_MEASURE and RFMXNR_ATTR_MODACC_NOISE_COMPENSATION_ENABLED attribute to RFMXNR_VAL_MODACC_NOISE_COMPENSATION_ENABLED_TRUE, the measurement attempts to read noise floor calibration data corresponding to the configured reference level. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. If noise floor calibration data corresponding to the configured reference level is not found in the calibration database, the measurement attempts to read noise floor calibration data from the calibration database for any reference level in the range of the configured reference level plus or minus the coercion limit you set for this attribute. The default value is 0.5. Get Function: RFmxNR_ModAccGetNoiseCompensationReferenceLevelCoercionLimit Set Function: RFmxNR_ModAccSetNoiseCompensationReferenceLevelCoercionLimit |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxNR_SetAttributeI32 RFmxNR_GetAttributeI32 |
Description: | Specifies whether the measurement should calibrate the noise floor of the analyzer or perform the ModAcc measurement. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXNR_VAL_MODACC_MEASUREMENT_MODE_MEASURE. Get Function: RFmxNR_ModAccGetMeasurementMode Set Function: RFmxNR_ModAccSetMeasurementMode |
Values: |
RFMXNR_VAL_MODACC_MEASUREMENT_MODE_MEASURE (0) | The ModAcc measurement is performed on the acquired signal. |
---|---|
RFMXNR_VAL_MODACC_MEASUREMENT_MODE_CALIBRATE_NOISE_FLOOR (1) | The ModAcc measurement measures the noise floor of the instrument across the frequency determined by the carrier frequency and the channel bandwidth. In this mode, the measurement expects the signal generator to be turned off and checks if there is any signal power detected at RFIn port of the analyzer beyond a certain threshold. All scalar results and traces are invalid in this mode. Even if the instrument noise floor is already calibrated, the measurement performs all the required acquisitions and overwrites any pre-existing noise floor calibration data. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxNR_SetAttributeI32 RFmxNR_GetAttributeI32 |
Description: | Enables averaging for the measurement. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXNR_VAL_MODACC_AVERAGING_ENABLED_FALSE. Get Function: RFmxNR_ModAccGetAveragingEnabled Set Function: RFmxNR_ModAccSetAveragingEnabled |
Values: |
RFMXNR_VAL_MODACC_AVERAGING_ENABLED_FALSE (0) | The measurement is performed on a single acquisition. |
---|---|
RFMXNR_VAL_MODACC_AVERAGING_ENABLED_TRUE (1) | The measurement is averaged over multiple acquisitions. The number of acquisitions is obtained by the RFMXNR_ATTR_MODACC_AVERAGING_COUNT attribute. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxNR_SetAttributeI32 RFmxNR_GetAttributeI32 |
Description: | Specifies the number of acquisitions used for averaging when you set the RFMXNR_ATTR_MODACC_AVERAGING_ENABLED attribute to RFMXNR_VAL_MODACC_AVERAGING_ENABLED_TRUE. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is 10. Get Function: RFmxNR_ModAccGetAveragingCount Set Function: RFmxNR_ModAccSetAveragingCount |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxNR_SetAttributeI32 RFmxNR_GetAttributeI32 |
Description: | Specifies whether to enable the traces to be stored and retrieved after performing the ModAcc measurement. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXNR_VAL_FALSE. Get Function: RFmxNR_ModAccGetAllTracesEnabled Set Function: RFmxNR_ModAccSetAllTracesEnabled |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxNR_SetAttributeI32 RFmxNR_GetAttributeI32 |
Description: | Specifies the maximum number of threads used for parallelism for the ModAcc measurement. The number of threads can range from 1 to the number of physical cores. The number of threads you set may not be used in calculations. The actual number of threads used depends on the problem size,system resources,data availability,and other considerations. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is 1. Get Function: RFmxNR_ModAccGetNumberOfAnalysisThreads Set Function: RFmxNR_ModAccSetNumberOfAnalysisThreads |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxNR_SetAttributeI32 RFmxNR_GetAttributeI32 |
Description: | Specifies whether the RFmxNR_ModAccAutoLevel function should search for the optimum reference levels while allowing ADC overflow. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXNR_VAL_MODACC_ATUO_LEVEL_ALLOW_OVERFLOW_FALSE. Get Function: RFmxNR_ModAccGetAutoLevelAllowOverflow Set Function: RFmxNR_ModAccSetAutoLevelAllowOverflow |
Values: |
RFMXNR_VAL_MODACC_ATUO_LEVEL_ALLOW_OVERFLOW_FALSE (0) | Disables searching for the optimum reference levels while allowing ADC overflow. |
---|---|
RFMXNR_VAL_MODACC_ATUO_LEVEL_ALLOW_OVERFLOW_TRUE (1) | Enables searching for the optimum reference levels while allowing ADC overflow. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxNR_SetAttributeI32 RFmxNR_GetAttributeI32 |
Description: | Specifies whether to enable the traces to be stored and retrieved after performing the ModAcc measurement. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXNR_VAL_FALSE. Get Function: RFmxNR_ModAccGetAllTracesEnabled Set Function: RFmxNR_ModAccSetAllTracesEnabled |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxNR_SetAttributeI32 RFmxNR_GetAttributeI32 |
Description: | Specifies the maximum number of threads used for parallelism for the ModAcc measurement. The number of threads can range from 1 to the number of physical cores. The number of threads you set may not be used in calculations. The actual number of threads used depends on the problem size,system resources,data availability,and other considerations. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is 1. Get Function: RFmxNR_ModAccGetNumberOfAnalysisThreads Set Function: RFmxNR_ModAccSetNumberOfAnalysisThreads |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxNR_GetAttributeF64 |
Description: | Returns the mean value of RMS EVMs calculated over measurement length. If ModAcc Composite Results Include DMRS attribute and ModAcc Composite Results Include PTRS attribute are set to False, EVM is computed only for the shared channel. When you set the RFMXNR_ATTR_MODACC_EVM_UNIT attribute to RFMXNR_VAL_MODACC_EVM_UNIT_PERCENTAGE, the measurement returns this result as a percentage. When you set the RFMXNR_ATTR_MODACC_EVM_UNIT attribute to RFMXNR_VAL_MODACC_EVM_UNIT_DB, the measurement returns this result in dB. Use 'carrier(k)' or 'subblock(n)' or 'subblock(n)/carrier(k)' as the Selector Strings to read this result. Get Function: RFmxNR_ModAccGetResultsCompositeRMSEVMMean |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxNR_GetAttributeF64 |
Description: | Returns the maximum value of peak EVMs calculated over measurement length. If ModAcc Composite Results Include DMRS attribute and ModAcc Composite Results Include PTRS attribute are set to False, EVM is computed only for the shared channel. When you set the RFMXNR_ATTR_MODACC_EVM_UNIT attribute to RFMXNR_VAL_MODACC_EVM_UNIT_PERCENTAGE, the measurement returns this result as a percentage. When you set the RFMXNR_ATTR_MODACC_EVM_UNIT attribute to RFMXNR_VAL_MODACC_EVM_UNIT_DB, the measurement returns this result in dB. Use 'carrier(k)' or 'subblock(n)' or 'subblock(n)/carrier(k)' as the Selector Strings to read this result. Get Function: RFmxNR_ModAccGetResultsCompositePeakEVMMaximum |
Data Type: | int32 |
---|---|
Access: | read only |
Functions: | RFmxNR_GetAttributeI32 |
Description: | Returns the bandwidth part index where ModAcc Results Max Pk Composite EVM occurs. Use 'carrier(k)' or 'subblock(n)' or 'subblock(n)/carrier(k)' as the Selector Strings to read this result. Get Function: RFmxNR_ModAccGetResultsCompositePeakEVMBWPIndex |
Data Type: | int32 |
---|---|
Access: | read only |
Functions: | RFmxNR_GetAttributeI32 |
Description: | Returns the slot index where ModAcc Results Max Pk Composite EVM occurs. Use 'carrier(k)' or 'subblock(n)' or 'subblock(n)/carrier(k)' as the Selector Strings to read this result. Get Function: RFmxNR_ModAccGetResultsCompositePeakEVMSlotIndex |
Data Type: | int32 |
---|---|
Access: | read only |
Functions: | RFmxNR_GetAttributeI32 |
Description: | Returns the symbol index where ModAcc Results Max Pk Composite EVM occurs. Use 'carrier(k)' or 'subblock(n)' or 'subblock(n)/carrier(k)' as the Selector Strings to read this result. Get Function: RFmxNR_ModAccGetResultsCompositePeakEVMSymbolIndex |
Data Type: | int32 |
---|---|
Access: | read only |
Functions: | RFmxNR_GetAttributeI32 |
Description: | Returns the subcarrier index where ModAcc Results Max Pk Composite EVM occurs. Use 'carrier(k)' or 'subblock(n)' or 'subblock(n)/carrier(k)' as the Selector Strings to read this result. Get Function: RFmxNR_ModAccGetResultsCompositePeakEVMSubcarrierIndex |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxNR_GetAttributeF64 |
Description: | Returns the RMS mean value of magnitude error calculated over measurement length on all configured channels. When you set the RFMXNR_ATTR_MODACC_EVM_UNIT attribute to RFMXNR_VAL_MODACC_EVM_UNIT_PERCENTAGE, the measurement returns this result as a percentage. When you set the RFMXNR_ATTR_MODACC_EVM_UNIT attribute to RFMXNR_VAL_MODACC_EVM_UNIT_DB, the measurement returns this result in dB. Use 'carrier(k)' or 'subblock(n)' or 'subblock(n)/carrier(k)' as the Selector Strings to read this result. Get Function: RFmxNR_ModAccGetResultsCompositeRMSMagnitudeErrorMean |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxNR_GetAttributeF64 |
Description: | Returns the peak value of magnitude error calculated over measurement length on all configured channels. When you set the RFMXNR_ATTR_MODACC_EVM_UNIT attribute to RFMXNR_VAL_MODACC_EVM_UNIT_PERCENTAGE, the measurement returns this result as a percentage. When you set the RFMXNR_ATTR_MODACC_EVM_UNIT attribute to RFMXNR_VAL_MODACC_EVM_UNIT_DB, the measurement returns this result in dB. Use 'carrier(k)' or 'subblock(n)' or 'subblock(n)/carrier(k)' as the Selector Strings to read this result. Get Function: RFmxNR_ModAccGetResultsCompositePeakMagnitudeErrorMaximum |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxNR_GetAttributeF64 |
Description: | Returns the RMS mean value of Phase error calculated over measurement length on all configured channels. This value is expressed in degrees. Use 'carrier(k)' or 'subblock(n)' or 'subblock(n)/carrier(k)' as the Selector Strings to read this result. Get Function: RFmxNR_ModAccGetResultsCompositeRMSPhaseErrorMean |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxNR_GetAttributeF64 |
Description: | Returns the peak value of Phase error calculated over measurement length on all configured channels. This value is expressed in degrees. Use 'carrier(k)' or 'subblock(n)' or 'subblock(n)/carrier(k)' as the Selector Strings to read this result. Get Function: RFmxNR_ModAccGetResultsCompositePeakPhaseErrorMaximum |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxNR_GetAttributeF64 |
Description: | Returns the mean value (over RFMXNR_ATTR_MODACC_MEASUREMENT_LENGTH) of power calculated on OFDM symbols allocated only with the shared channel. Use 'carrier(k)' or 'subblock(n)' or 'subblock(n)/carrier(k)' as the Selector Strings to read this result. Get Function: RFmxNR_ModAccGetResultsSCHSymbolPowerMean |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxNR_GetAttributeF64 |
Description: | Returns the mean value of RMS EVMs calculated over measurement length on PUSCH data symbols. When you set the RFMXNR_ATTR_MODACC_EVM_UNIT attribute to RFMXNR_VAL_MODACC_EVM_UNIT_PERCENTAGE, the measurement returns this result as a percentage. When you set the RFMXNR_ATTR_MODACC_EVM_UNIT attribute to RFMXNR_VAL_MODACC_EVM_UNIT_DB, the measurement returns this result in dB. Use 'user(l)' or 'bwp(m)' or 'carrier(k)' or 'subblock(n)' or 'subblock(n)/carrier(k)/bwp(m)/user(l)' as the Selector Strings to read this result. Get Function: RFmxNR_ModAccGetResultsPUSCHDataRMSEVMMean |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxNR_GetAttributeF64 |
Description: | Returns the maximum value of peak EVMs calculated over measurement length on PUSCH data symbols. When you set the RFMXNR_ATTR_MODACC_EVM_UNIT attribute to RFMXNR_VAL_MODACC_EVM_UNIT_PERCENTAGE, the measurement returns this result as a percentage. When you set the RFMXNR_ATTR_MODACC_EVM_UNIT attribute to RFMXNR_VAL_MODACC_EVM_UNIT_DB, the measurement returns this result in dB. Use 'user(l)' or 'bwp(m)' or 'carrier(k)' or 'subblock(n)' or 'subblock(n)/carrier(k)/bwp(m)/user(l)' as the Selector Strings to read this result. Get Function: RFmxNR_ModAccGetResultsPUSCHDataPeakEVMMaximum |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxNR_GetAttributeF64 |
Description: | Returns the mean value of RMS EVMs calculated over measurement length on PUSCH DMRS. When you set the RFMXNR_ATTR_MODACC_EVM_UNIT attribute to RFMXNR_VAL_MODACC_EVM_UNIT_PERCENTAGE, the measurement returns this result as a percentage. When you set the RFMXNR_ATTR_MODACC_EVM_UNIT attribute to RFMXNR_VAL_MODACC_EVM_UNIT_DB, the measurement returns this result in dB. Use 'user(l)' or 'bwp(m)' or 'carrier(k)' or 'subblock(n)' or 'subblock(n)/carrier(k)/bwp(m)/user(l)' as the Selector Strings to read this result. Get Function: RFmxNR_ModAccGetResultsPUSCHDMRSRMSEVMMean |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxNR_GetAttributeF64 |
Description: | Returns the maximum value of peak EVMs calculated over measurement length on PUSCH DMRS. When you set the RFMXNR_ATTR_MODACC_EVM_UNIT attribute to RFMXNR_VAL_MODACC_EVM_UNIT_PERCENTAGE, the measurement returns this result as a percentage. When you set the RFMXNR_ATTR_MODACC_EVM_UNIT attribute to RFMXNR_VAL_MODACC_EVM_UNIT_DB, the measurement returns this result in dB. Use 'user(l)' or 'bwp(m)' or 'carrier(k)' or 'subblock(n)' or 'subblock(n)/carrier(k)/bwp(m)/user(l)' as the Selector Strings to read this result. Get Function: RFmxNR_ModAccGetResultsPUSCHDMRSPeakEVMMaximum |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxNR_GetAttributeF64 |
Description: | Returns the mean value of RMS EVMs calculated over measurement length on PUSCH PTRS. When you set the RFMXNR_ATTR_MODACC_EVM_UNIT attribute to RFMXNR_VAL_MODACC_EVM_UNIT_PERCENTAGE, the measurement returns this result as a percentage. When you set the RFMXNR_ATTR_MODACC_EVM_UNIT attribute to RFMXNR_VAL_MODACC_EVM_UNIT_DB, the measurement returns this result in dB. Use 'user(l)' or 'bwp(m)' or 'carrier(k)' or 'subblock(n)' or 'subblock(n)/carrier(k)/bwp(m)/user(l)' as the Selector Strings to read this result. Get Function: RFmxNR_ModAccGetResultsPUSCHPTRSRMSEVMMean |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxNR_GetAttributeF64 |
Description: | Returns the maximum value of peak EVMs calculated over measurement length on PUSCH PTRS. When you set the RFMXNR_ATTR_MODACC_EVM_UNIT attribute to RFMXNR_VAL_MODACC_EVM_UNIT_PERCENTAGE, the measurement returns this result as a percentage. When you set the RFMXNR_ATTR_MODACC_EVM_UNIT attribute to RFMXNR_VAL_MODACC_EVM_UNIT_DB, the measurement returns this result in dB. Use 'user(l)' or 'bwp(m)' or 'carrier(k)' or 'subblock(n)' or 'subblock(n)/carrier(k)/ bwp(m)/ user(l)' as the Selector Strings to read this attribute. Get Function: RFmxNR_ModAccGetResultsPUSCHPTRSPeakEVMMaximum |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxNR_GetAttributeF64 |
Description: | Returns the mean value of RMS EVMs calculated over measurement length on all QPSK modulated PDSCH data symbols. When you set the RFMXNR_ATTR_MODACC_EVM_UNIT attribute to RFMXNR_VAL_MODACC_EVM_UNIT_PERCENTAGE, the measurement returns this result as a percentage. When you set the RFMXNR_ATTR_MODACC_EVM_UNIT attribute to RFMXNR_VAL_MODACC_EVM_UNIT_DB, the measurement returns this result in dB. Use 'bwp(m)' or 'carrier(k)' or 'subblock(n)' or 'subblock(n)/carrier(k)/bwp(m)' as the Selector Strings to read this result. Get Function: RFmxNR_ModAccGetResultsPDSCHQPSKRMSEVMMean |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxNR_GetAttributeF64 |
Description: | Returns the mean value of RMS EVMs calculated over measurement length on all 16 QAM modulated PDSCH data symbols. When you set the RFMXNR_ATTR_MODACC_EVM_UNIT attribute to RFMXNR_VAL_MODACC_EVM_UNIT_PERCENTAGE, the measurement returns this result as a percentage. When you set the RFMXNR_ATTR_MODACC_EVM_UNIT attribute to RFMXNR_VAL_MODACC_EVM_UNIT_DB, the measurement returns this result in dB. Use 'bwp(m)' or 'carrier(k)' or 'subblock(n)' or 'subblock(n)/carrier(k)/bwp(m)' as the Selector Strings to read this result. Get Function: RFmxNR_ModAccGetResultsPDSCH16QAMRMSEVMMean |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxNR_GetAttributeF64 |
Description: | Returns the mean value of RMS EVMs calculated over measurement length on all 64 QAM modulated PDSCH data symbols. When you set the RFMXNR_ATTR_MODACC_EVM_UNIT attribute to RFMXNR_VAL_MODACC_EVM_UNIT_PERCENTAGE, the measurement returns this result as a percentage. When you set the RFMXNR_ATTR_MODACC_EVM_UNIT attribute to RFMXNR_VAL_MODACC_EVM_UNIT_DB, the measurement returns this result in dB. Use 'bwp(m)' or 'carrier(k)' or 'subblock(n)' or 'subblock(n)/carrier(k)/bwp(m)' as the Selector Strings to read this result. Get Function: RFmxNR_ModAccGetResultsPDSCH64QAMRMSEVMMean |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxNR_GetAttributeF64 |
Description: | Returns the mean value of RMS EVMs calculated over measurement length on all 256 QAM modulated PDSCH data symbols. When you set the RFMXNR_ATTR_MODACC_EVM_UNIT attribute to RFMXNR_VAL_MODACC_EVM_UNIT_PERCENTAGE, the measurement returns this result as a percentage. When you set the RFMXNR_ATTR_MODACC_EVM_UNIT attribute to RFMXNR_VAL_MODACC_EVM_UNIT_DB, the measurement returns this result in dB. Use 'bwp(m)' or 'carrier(k)' or 'subblock(n)' or 'subblock(n)/carrier(k)/bwp(m)' as the Selector Strings to read this result. Get Function: RFmxNR_ModAccGetResultsPDSCH256QAMRMSEVMMean |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxNR_GetAttributeF64 |
Description: | Returns the mean value of RMS EVMs calculated over measurement length on all 1024 QAM modulated PDSCH data symbols. When you set the RFMXNR_ATTR_MODACC_EVM_UNIT attribute to RFMXNR_VAL_MODACC_EVM_UNIT_PERCENTAGE, the measurement returns this result as a percentage. When you set the RFMXNR_ATTR_MODACC_EVM_UNIT attribute to RFMXNR_VAL_MODACC_EVM_UNIT_DB, the measurement returns this result in dB. Use 'bwp(m)' or 'carrier(k)' or 'subblock(n)' or 'subblock(n)/carrier(k)/bwp(m)' as the Selector Strings to read this result. Get Function: RFmxNR_ModAccGetResultsPDSCH1024QAMRMSEVMMean |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxNR_GetAttributeF64 |
Description: | Returns the mean value of RMS EVMs calculated over measurement length on all 8 PSK modulated PDSCH data symbols. Use 'bwp(m)' or 'carrier(k)' or 'subblock(n)' or 'subblock(n)/carrier(k)/bwp(m)' as the Selector Strings to read this result. Get Function: RFmxNR_ModAccGetResultsPDSCH8PSKRMSEVMMean |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxNR_GetAttributeF64 |
Description: | Returns the mean value of RMS EVMs calculated over measurement length on PDSCH data symbols. When you set the RFMXNR_ATTR_MODACC_EVM_UNIT attribute to RFMXNR_VAL_MODACC_EVM_UNIT_PERCENTAGE, the measurement returns this result as a percentage. When you set the RFMXNR_ATTR_MODACC_EVM_UNIT attribute to RFMXNR_VAL_MODACC_EVM_UNIT_DB, the measurement returns this result in dB. Use 'user(l)' or 'bwp(m)' or 'carrier(k)' or 'subblock(n)' or 'subblock(n)/carrier(k)/bwp(m)/user(l)' as the Selector Strings to read this result. Get Function: RFmxNR_ModAccGetResultsPDSCHDataRMSEVMMean |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxNR_GetAttributeF64 |
Description: | Returns the maximum value of peak EVMs calculated over measurement length on PDSCH data symbols. When you set the RFMXNR_ATTR_MODACC_EVM_UNIT attribute to RFMXNR_VAL_MODACC_EVM_UNIT_PERCENTAGE, the measurement returns this result as a percentage. When you set the RFMXNR_ATTR_MODACC_EVM_UNIT attribute to RFMXNR_VAL_MODACC_EVM_UNIT_DB, the measurement returns this result in dB. Use 'user(l)' or 'bwp(m)' or 'carrier(k)' or 'subblock(n)' or 'subblock(n)/carrier(k)/bwp(m)/user(l)' as the Selector Strings to read this result. Get Function: RFmxNR_ModAccGetResultsPDSCHDataPeakEVMMaximum |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxNR_GetAttributeF64 |
Description: | Returns the mean value of RMS EVMs calculated over measurement length on PDSCH DMRS. When you set the RFMXNR_ATTR_MODACC_EVM_UNIT attribute to RFMXNR_VAL_MODACC_EVM_UNIT_PERCENTAGE, the measurement returns this result as a percentage. When you set the RFMXNR_ATTR_MODACC_EVM_UNIT attribute to RFMXNR_VAL_MODACC_EVM_UNIT_DB, the measurement returns this result in dB. Use 'user(l)' or 'bwp(m)' or 'carrier(k)' or 'subblock(n)' or 'subblock(n)/carrier(k)/bwp(m)/user(l)' as the Selector Strings to read this result. Get Function: RFmxNR_ModAccGetResultsPDSCHDMRSRMSEVMMean |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxNR_GetAttributeF64 |
Description: | Returns the maximum value of peak EVMs calculated over measurement length on PDSCH DMRS. When you set the RFMXNR_ATTR_MODACC_EVM_UNIT attribute to RFMXNR_VAL_MODACC_EVM_UNIT_PERCENTAGE, the measurement returns this result as a percentage. When you set the RFMXNR_ATTR_MODACC_EVM_UNIT attribute to RFMXNR_VAL_MODACC_EVM_UNIT_DB, the measurement returns this result in dB. Use 'user(l)' or 'bwp(m)' or 'carrier(k)' or 'subblock(n)' or 'subblock(n)/carrier(k)/bwp(m)/user(l)' as the Selector Strings to read this result. Get Function: RFmxNR_ModAccGetResultsPDSCHDMRSPeakEVMMaximum |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxNR_GetAttributeF64 |
Description: | Returns the mean value of RMS EVMs calculated over measurement length on PDSCH PTRS. When you set the RFMXNR_ATTR_MODACC_EVM_UNIT attribute to RFMXNR_VAL_MODACC_EVM_UNIT_PERCENTAGE, the measurement returns this result as a percentage. When you set the RFMXNR_ATTR_MODACC_EVM_UNIT attribute to RFMXNR_VAL_MODACC_EVM_UNIT_DB, the measurement returns this result in dB. Use 'user(l)' or 'bwp(m)' or 'carrier(k)' or 'subblock(n)' or 'subblock(n)/carrier(k)/bwp(m)/user(l)' as the Selector Strings to read this result. Get Function: RFmxNR_ModAccGetResultsPDSCHPTRSRMSEVMMean |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxNR_GetAttributeF64 |
Description: | Returns the maximum value of peak EVMs calculated over measurement length on PDSCH PTRS. When you set the RFMXNR_ATTR_MODACC_EVM_UNIT attribute to RFMXNR_VAL_MODACC_EVM_UNIT_PERCENTAGE, the measurement returns this result as a percentage. When you set the RFMXNR_ATTR_MODACC_EVM_UNIT attribute to RFMXNR_VAL_MODACC_EVM_UNIT_DB, the measurement returns this result in dB. Use 'user(l)' or 'bwp(m)' or 'carrier(k)' or 'subblock(n)' or 'subblock(n)/carrier(k)/bwp(m)/user(l)' as the Selector Strings to read this result. Get Function: RFmxNR_ModAccGetResultsPDSCHPTRSPeakEVMMaximum |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxNR_GetAttributeF64 |
Description: | Returns In-Band Emission Margin of the component carrier. This value is expressed in dB. Margin is the smallest difference between In-Band Emission measurement trace and limit trace. The limit is defined in the section 6.4.2.3 of 3GPP 38.101-1 specification and section 6.4.2.3 of 3GPP 38.101-2 specification. In-Band emission is measured as the ratio of the power in non-allocated resource blocks to the power in the allocated resource blocks averaged over the measurement interval. The margin is not returned in case of clustered PUSCH allocation, or when there is full allocation of resource blocks. Use 'carrier(k)' or 'subblock(n)' or 'subblock(n)/carrier(k)' as the Selector Strings to read this result. Get Function: RFmxNR_ModAccGetResultsInBandEmissionMargin |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxNR_GetAttributeF64 |
Description: | Returns In-Band Emission Margin of the subblock's aggregated bandwidth. This value is expressed in dB. Margin is the smallest difference between In-Band Emission measurement trace and the limit trace. The limit is defined in section 6.4A.2.2.2 of 3GPP 38.101-1 specification and section 6.4A.2.3 of 3GPP 38.101-2 specification. In-Band emission is measured as the ratio of the power in non-allocated resource blocks to the power in the allocated resource blocks averaged over the measurement interval. The margin is not returned in case of clustered PUSCH allocation, or when there is more than one active carrier, or when there is full allocation of resource blocks, or when carriers with different sub-carrier spacing are aggregated or when the number of carriers is greater than 2. Use 'subblock(n)' as the Selector Strings to read this attribute. Get Function: RFmxNR_ModAccGetResultsSubblockInBandEmissionMargin |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxNR_GetAttributeF64 |
Description: | Returns the peak-to-peak ripple of the magnitude of EVM equalizer coefficients within Range1 for the measurement unit, that has the worst ripple margin among all four ripple results defined in section 6.4.2.4.1 of 3GPP 38.101-1 specification and section 6.4.2.4.1 of 3GPP 38.101-2 specification. This value is expressed in dB. Use 'carrier(k)' or 'subblock(n)' or 'subblock(n)/carrier(k)' as the Selector Strings to read this result. Get Function: RFmxNR_ModAccGetResultsSpectralFlatnessRange1MaximumToRange1Minimum |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxNR_GetAttributeF64 |
Description: | Returns the peak-to-peak ripple of the magnitude of EVM equalizer coefficients within Range2 for the Measurement unit, that has the worst ripple margin among all four ripple results defined in section 6.4.2.4.1 of 3GPP 38.101-1 specification and section 6.4.2.4.1 of 3GPP 38.101-2 specification. This value is expressed in dB. Use 'carrier(k)' or 'subblock(n)' or 'subblock(n)/carrier(k)' as the Selector Strings to read this result. Get Function: RFmxNR_ModAccGetResultsSpectralFlatnessRange2MaximumToRange2Minimum |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxNR_GetAttributeF64 |
Description: | Returns the peak-to-peak ripple of the EVM equalizer coefficients from maximum in Range1 to minimum in Range2 for the Measurement unit that has the worst ripple margin among all four ripple results defined in 3section 6.4.2.4.1 of 3GPP 38.101-1 specification and section 6.4.2.4.1 of 3GPP 38.101-2 specification. This value is expressed in dB. Use 'carrier(k)' or 'subblock(n)' or 'subblock(n)/carrier(k)' as the Selector Strings to read this result. Get Function: RFmxNR_ModAccGetResultsSpectralFlatnessRange1MaximumToRange2Minimum |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxNR_GetAttributeF64 |
Description: | Returns the peak-to-peak ripple of the EVM equalizer coefficients from maximum in Range2 to minimum in Range1 for the Measurement unit that has the worst ripple margin among all four ripple results defined in section 6.4.2.4.1 of 3GPP 38.101-1 specification and section 6.4.2.4.1 of 3GPP 38.101-2 specification. This value is expressed in dB. Use 'carrier(k)' or 'subblock(n)' or 'subblock(n)/carrier(k)' as the Selector Strings to read this result. Get Function: RFmxNR_ModAccGetResultsSpectralFlatnessRange2MaximumToRange1Minimum |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxNR_GetAttributeF64 |
Description: | Returns the time difference between the detected slot or frame boundary depending on the sync mode and reference trigger location. This value is expressed in seconds. Use 'carrier(k)' or 'subblock(n)' or 'subblock(n)/carrier(k)' as the Selector Strings to read this result. Get Function: RFmxNR_ModAccGetResultsComponentCarrierTimeOffsetMean |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxNR_GetAttributeF64 |
Description: | Returns the estimated carrier frequency offset averaged over measurement length. This value is expressed in Hz. Use 'carrier(k)' or 'subblock(n)' or 'subblock(n)/carrier(k)' as the Selector Strings to read this result. Get Function: RFmxNR_ModAccGetResultsComponentCarrierFrequencyErrorMean |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxNR_GetAttributeF64 |
Description: | Returns the estimated sample clock error averaged over measurement length. This value is expressed in ppm. Use 'carrier(k)' or 'subblock(n)' or 'subblock(n)/carrier(k)' as the Selector Strings to read this result. Get Function: RFmxNR_ModAccGetResultsComponentCarrierSymbolClockErrorMean |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxNR_GetAttributeF64 |
Description: | Returns the estimated IQ origin offset averaged over measurement length. This value is expressed in dBc. Use 'carrier(k)' or 'subblock(n)' or 'subblock(n)/carrier(k)' as the Selector Strings to read this result. Get Function: RFmxNR_ModAccGetResultsComponentCarrierIQOriginOffsetMean |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxNR_GetAttributeF64 |
Description: | Returns the estimated IQ gain imbalance averaged over measurement length. This value is expressed in dB. IQ gain imbalance is the ratio of the amplitude of the I component to the Q component of the IQ signal being measured. Use 'carrier(k)' or 'subblock(n)' or 'subblock(n)/carrier(k)' as the Selector Strings to read this result. Get Function: RFmxNR_ModAccGetResultsComponentCarrierIQGainImbalanceMean |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxNR_GetAttributeF64 |
Description: | Returns the estimated quadrature error averaged over measurement length. This value is expressed in degrees. Quadrature error is the measure of skewness in degree of the I component with respect to the Q component of the IQ signal being measured. Use 'carrier(k)' or 'subblock(n)' or 'subblock(n)/carrier(k)' as the Selector Strings to read this result. Get Function: RFmxNR_ModAccGetResultsComponentCarrierQuadratureErrorMean |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxNR_GetAttributeF64 |
Description: | Returns the estimated IQ Timing Skew averaged over Meas Length. Use 'carrier(k)' or 'subblock(n)' or 'subblock(n)/carrier(k)' as the Selector Strings to read this result. IQ Timing skew is the difference between the group delay of the in-phase (I) and quadrature (Q) components of the signal. This value is expressed in seconds. Get Function: RFmxNR_ModAccGetResultsComponentCarrierIQTimingSkewMean |
Data Type: | int32 |
---|---|
Access: | read only |
Functions: | RFmxNR_GetAttributeI32 |
Description: | Returns the index of the component carrier that includes the LO of the transmitter according to the RFMXNR_ATTR_SUBBLOCK_FREQUENCY_DEFINITION and RFMXNR_ATTR_SUBBLOCK_TRANSMIT_LO_FREQUENCY attributes. If the LO of the transmitter doesn't fall into any component carrier of the subblock, the attribute returns -1. This result is valid only when you set the RFMXNR_ATTR_TRANSMITTER_ARCHITECTURE attribute to RFMXNR_VAL_TRANSMITTER_ARCHITECTURE_LO_PER_SUBBLOCK. Use 'subblock(n)' as the Selector Strings to read this result. Get Function: RFmxNR_ModAccGetResultsSubblockLOComponentCarrierIndex |
Data Type: | int32 |
---|---|
Access: | read only |
Functions: | RFmxNR_GetAttributeI32 |
Description: | Returns the subcarrier index within the respective component carrier where the transmitter LO is located. Due to its dependence on RFMXNR_ATTR_SUBBLOCK_FREQUENCY_DEFINITION and RFMXNR_ATTR_SUBBLOCK_TRANSMIT_LO_FREQUENCY attributes, the value can be fractional, and the LO might reside in between subcarriers of a component carrier. This result is valid only when you set the RFMXNR_ATTR_TRANSMITTER_ARCHITECTURE attribute to RFMXNR_VAL_TRANSMITTER_ARCHITECTURE_LO_PER_SUBBLOCK. Use 'subblock(n)' as the Selector Strings to read this result. Get Function: RFmxNR_ModAccGetResultsSubblockLOSubcarrierIndex |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxNR_GetAttributeF64 |
Description: | Returns the estimated IQ origin offset averaged over measurement length in the subblock. This value is expressed in dBc. This result is valid only when you set the RFMXNR_ATTR_TRANSMITTER_ARCHITECTURE attribute to RFMXNR_VAL_TRANSMITTER_ARCHITECTURE_LO_PER_SUBBLOCK. Use 'carrier(k)' or 'subblock(n)' or 'subblock(n)/carrier(k)' as the Selector Strings to read this result. Get Function: RFmxNR_ModAccGetResultsSubblockIQOriginOffsetMean |
Data Type: | int32 |
---|---|
Access: | read only |
Functions: | RFmxNR_GetAttributeI32 |
Description: | Specifies whether the noise compensation is applied to the EVM measurement. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for the named signals. The default value is RFMXNR_VAL_MODACC_RESULTS_NOISE_COMPENSATION_APPLIED_FALSE. Get Function: RFmxNR_ModAccGetResultsNoiseCompensationApplied |
Values: |
RFMXNR_VAL_MODACC_RESULTS_NOISE_COMPENSATION_APPLIED_FALSE (0) | Noise compensation is not applied to the EVM measurement. |
---|---|
RFMXNR_VAL_MODACC_RESULTS_NOISE_COMPENSATION_APPLIED_TRUE (1) | Noise compensation is applied to the EVM measurement. |
Creating and Setting Up a gRPC Server
Session Utilities API Reference
gRPC API Differences From C API
Sharing Driver Sessions Between Clients
C API Docs
NI-DAQmx
- gRPC API Differences From C API
- Task Configuration And Control
- Channel Configuration And Creation
- Timing
- Triggering
- Read Functions
- Write Functions
- Export Hardware Signals
- Scale Configuration
- Internal Buffer Configuration
- Advanced Functions
- System Configuration
- Error Handling
- Buffer Attributes
- Calibration Info Attributes
- Channel Attributes
- Device Attributes
- Export Signal Attributes
- Persisted Channel Attributes
- Persisted Scale Attributes
- Persisted Task Attributes
- Physical Channel Attributes
- Read Attributes
- Scale Attributes
- System Attributes
- Task Attributes
- Timing Attributes
- Trigger Attributes
- Watchdog Attributes
- Write Attributes
NI-DCPOWER
- Setup Functions
- Configure Functions
- Measurement Functions
- Control Functions
- Trigger And Event
- Attribute Functions
- Query Functions
- Calibration Functions
- Utility Functions
- Supported Device
- Source Attributes
- Transient Attributes
- Voltage Attributes
- Current Attributes
- Pulse Voltage Attributes
- Pulse Current Attributes
- Cutoff Attributes
- Measurement Attributes
- Trigger Attributes Functions
- Event Attributes
- Advanced Attributes
- Inherent Ivi Attributes
- Supported Device Attributes
NI-DIGITAL PATTERN DRIVER
- Init And Close Functions
- Session Locking Functions
- Utility Functions
- Error Handling Functions
- Calibration Functions
- Attributes Functions
- Pin Map Functions
- Low Level Functions
- Low Level Action Functions
- Pin Control Functions
- Static IO Functions
- Clock Generator Functions
- Levels And Timing Functions
- TDR Functions
- PPMU Configuration Functions
- DC Voltage Functions
- DC Current Functions
- PPMU Action Functions
- Pattern Configuration Functions
- Pattern Action Functions
- History Ram Functions
- Source Memory Functions
- Capture Memory Functions
- Triggers And Events Functions
- Conditional Jump Trigger Functions
- Sequencer Flag Functions
- Sequencer Register Functions
- Match Fail Combination Functions
- Pattern Results Functions
- Sort Results Functions
- Frequency Measurement Functions
- IVI Inherent Attributes
- Specific Driver Information Attributes, Read Only
- Driver Setup Information Attributes
- Device Attributes
- Pin Control Attributes
- Level Configuration Attributes
- Trigger Configuration Attributes
- PPMU Attributes
- Patterns Attributes
- Pattern Opcode Event Attributes
- Timing Offset Attributes
- Keep Alive Attributes
- Frequency Measurement Attributes
- Clock Generator Attributes
- History RAM
- Synchronization Attributes
- TDR Endpoint Termination Attributes
NI-FGEN
- Setup Functions
- Configuration Functions
- Standard Output Functions
- Arbitrary Waveform Output Functions
- Arbitrary Sequence Output Functions
- Incremental Waveform Write Functions
- Configure Clock Functions
- Trigger And Syncronizations Functions
- 5404 Routing Functions
- Script Output Functions
- Configure Onboard Signal Processing Functions
- Configure Peer To Peer Functions
- Attribute Functions
- Waveform Control Functions
- Error Functions
- Output Attributes
- Arbitrary Waveform Attributes
- Data Transfer Attributes
- Onboard Signal Processing Attributes
- Peer To Peer Attributes
- Standard Function Attributes
- Clock Attributes
- Event Attributes
- Triggering Attributes
- Instrument Specific Attributes
- Inherent IVI Attributes
- 5401 5411 5431
NI-RFmx Bluetooth
- gRPC API Differences From C API
- General Functions
- Configuration Functions
- Set And Get Attribute Functions
- Fetch Results Functions
- Utility Functions
- Build String Functions
- Advanced Functions
- General Attributes
- Trigger Attributes
- Packet Attributes
- Auto Detect Signal Attributes
- Modacc Attributes
- ACP Attributes
- Twenty dB Attributes
- Frequency Range Attributes
- TXP Attributes
- Advanced Attributes
NI-RFmx NR
- gRPC API Differences From C API
- General Functions
- Configuration Functions
- Set And Get Attributes Functions
- Fetch Results Functions
- Utility Functions
- Build String Functions
- Advanced Functions
- General Attributes
- Trigger Attributes
- Signal Detection Attributes
- Component Carrier Attributes
- List Attributes
- Modacc Attributes
- ACP Attributes
- CHP Attributes
- OBW Attributes
- SEM Attributes
- TXP Attributes
- Pvt Attributes
- Advanced Attributes
NI-RFmx LTE
- gRPC API Differences From C API
- General Functions
- Configuration Functions
- Ch Configuration Functions
- NB IoT Configuration Functions
- ModAcc Configuration Functions
- ACP Configuration Functions
- CHP Configuration Functions
- OBW Configuration Functions
- SEM Configuration Functions
- PVT Configuration Functions
- SlotPhase Configuration Functions
- SlotPower Configuration Functions
- Set And Get Attribute Functions
- ModAcc Fetch Functions
- ACP Fetch Functions
- CHP Fetch Functions
- OBW Fetch Functions
- SEM Fetch Functions
- PVT Fetch Functions
- SlotPhase Fetch Functions
- SlotPower Fetch Functions
- Utility Functions
- Build String Functions
- Advanced Functions
- General Attributes
- Trigger Attributes
- Component Carrier Attributes
- ModAcc Attributes
- ACP Attributes
- CHP Attributes
- OBW Attributes
- SEM Attributes
- PVT Attributes
- SlotPhase Attributes
- SlotPower Attributes
- Advanced Attributes
NI-RFmx SpecAn
- gRPC API Differences From C API
- General Functions
- Configuration Functions
- Set And Get Attribute Functions
- Read Functions
- Fetch Functions
- Utility Functions
- Marker Functions
- Build String Functions
- Advanced Functions
- General Attributes
- Trigger Attributes
- ACP Attributes
- Cdf Attributes
- CHP Attributes
- Fcnt Attributes
- Harm Attributes
- OBW Attributes
- SEM Attributes
- Spectrum Attributes
- Spur Attributes
- TXP Attributes
- AMPM Attributes
- Dpd Attributes
- IQ Attributes
- IM Attributes
- NF Attributes
- Phasenoise Attributes
- PAVT Attributes
- Advanced Attributes
NI-RFmx WLAN
- gRPC API Differences From C API
- General Functions
- Configuration Functions
- Set And Get Attribute Functions
- Fetch DSSS ModAcc Functions
- Fetch OFDM ModAcc Functions
- Fetch SEM Functions
- Fetch TXP Functions
- Fetch PowerRamp Functions
- Utility Functions
- Build String Functions
- Advanced Functions
- General Attributes
- Trigger Attributes
- OFDM Attributes
- Auto Detect Signal Attributes
- DSSS ModAcc Attributes
- OFDM ModAcc Attributes
- SEM Attributes
- TXP Attributes
- PowerRamp Attributes
- Advanced Attributes
NI-RFSA
- General Functions
- Configuration Functions
- Acquisition Functions
- Utility Functions
- Calibration Functions
- General Attributes
- Vertical Attributes
- Signal Path Attributes
- Acquisition Attributes
- Acquisition Attributes
- Triggers Attributes
- Events Attributes
- Device Characteristics Attributes
- Peer To Peer Streaming Attributes
- Configuration List Attributes
- Inherent IVI Properties Attributes
- De-embedding Attributes
- Self Calibration Attributes
- Factory Calibration Attributes
- External Alignment Attributes
- Device Specific Attributes
NI-RFSG
- General Functions
- Generation Configuration
- Utility Functions
- Calibration Functions
- Arb Attributes
- Clock Attributes
- Configuration List Attributes
- De-embedding Attributes
- Device Characteristics Attributes
- Device Specific Attributes
- Events Attributes
- External Calibration Attributes
- Inherent IVI Attributes Attributes
- IQ Impairment Attributes
- Load Configurations Attributes
- Modulation Attributes
- Obsolete Attributes
- Peer To Peer Attributes
- RF Attributes
- Self Calibration Attributes
- Triggers Attributes
NI-SCOPE
- Setup Functions
- Configure Functions
- Attribute Functions
- Acquisition Functions
- Measurement Functions
- Calibrate Functions
- Utility Funcitons
- Error Handling Functions
- IVI Compliance Or Obsolete Functions
- Vertical Attributes
- Horizontal Attributes
- Trigger Attributes
- Clocking Attributes
- Synchronization Attributes
- Acquisition Attributes
- Waveform Measurements Attributes
- Onboard Signal Processing Attributes
- Peer To Peer Streaming Attributes
- Device Attributes
- IVI Or Obsolete Attributes
- Instrument Capabilities Attributes
- If Digitizer Attributes
NI-XNET
- gRPC API differences from C APIs
- General Functions
- Cluster Properties
- Database Properties
- Device Properties
- ECU Properties
- Frame Properties
- Interface Properties
- LIN Schedule Entry Properties
- LIN Schedule Properties
- PDU Properties
- Session Ethernet Properties
- Session Frame Properties
- Session Interface Properties
- Session Properties
- Session SAE J1939 Properties
- Signal Properties
- Subframe Properties
- System Properties
- IP-Stack Functions
- Socket Options
- Socket Functions