If the heating system is running in automatic mode (and only(!) then), you can use the parameter 10110 (heating circuit 1 / HC1), 10111 (HC2) and 10112 (HC3) to switch between comfort and reduced mode. Each mode change is only effective until the next switching time.
To switch from comfort mode to reduced mode in HC1, call this URL:
http://bsb-lan.local/S10110=1
And to switch from reduced mode to comfort mode, call this URL:
http://bsb-lan.local/S10110=2
Again, please note that this function only works in automatic mode. Furthermore, these parameters cannot be read, so you have to keep track of the status via other parameters.