Fix boot error in analytics config-checker code... #14

Merged
merged 1 commit into from
Oct 30, 2020
Merged
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
33 changes: 21 additions & 12 deletions src/GasExposureAnalytics.py
Original file line number Diff line number Diff line change
Expand Up @@ -89,24 +89,33 @@ def _validate_config(self, config_filename) :
critical_config_issues += [message]

# For each supported gas, check that limits PPM configuration is within that sensor's range.
# The limits should be no less than double the range of the sensor. To to illustrate why:
# Say a firefighter experiences [30mins at 1ppm. Then 30mins at 25ppm] and the 1hr limit is 10ppm. Then one
# hour into the fire, this firefighter has experienced an average of 13ppm per hour, well over the 10ppm
# The limits must be less than the range of the sensor. For best reporting, the range should be at least
# two or more times the upper limit and a warning will be produced if this is not the case. To to illustrate
# why: Say a firefighter experiences [30mins at 1ppm. Then 30mins at 25ppm] and the 1hr limit is 10ppm. Then
# one hour into the fire, this firefighter has experienced an average of 13ppm per hour, well over the 10ppm
# limit - their status should be ‘Red’. However, if the range of the sensor is 0-10ppm, then the command center
# would actually see their status as *Green* (not Red or even Yellow) with a 5.5ppm per hour average - seemingly
# well under the limit. Why? Because the sensor would have provided [30mins at 1ppm. Then 30mins at 10ppm] which
# averages to 5.5ppm. For time-weighted average math to give reliable results, the sensor must have a much
# larger range than the limits - 2x being a minimum. If the limit is set at or near the sensor range, a
# firefighter's status would essentially never go red, even if they were well over the limit.
# would actually see their status as *Range Exceeded* (not Red, Yellow or Green), which is not very helpful.
# It's essentially saying "this firefighter's average exposure is unknown - it may be OK or it may not.
# Prometeo can't tell, because the sensors aren't sensitive enough for these conditions". For the firefighter
# to get an accurate report, this sensor would need to have a range of at least 25ppm (and likely more),
# so that exposure could be accurately measured and averaged to 13ppm.
# (Note: the sensor returns *Range Exceeded* to prevent incorrect PPM averages from being calculated.
# e.g. in the above scenario, we do not want to incorrectly calculate an average of 5.5ppm (Green) from a
# sensor showing 30mins at 1ppm and 30mins at 10ppm, the max the sensor can 'see').
for gas in self.SUPPORTED_GASES :
limits = [window[GAS_LIMITS_PROPERTY][gas] for window in self.WINDOWS_AND_LIMITS]
if ( (min(limits) < SENSOR_RANGE_PPM[gas]['min']) or ((max(limits)*2) > SENSOR_RANGE_PPM[gas]['max']) ) :
if ( (min(limits) < SENSOR_RANGE_PPM[gas]['min']) or (max(limits) > SENSOR_RANGE_PPM[gas]['max']) ) :
valid_config = False
message = ("%s : One or more of the '%s' configurations %s is incompatible with the range of the '%s' sensor (min: %s, max: %s)." +
"\nPlease note that sensors must have a much larger range than the limits - 2x being a minimum.") \
message = ("%s : One or more of the '%s' configurations %s is incompatible with the range of the '%s' sensor (min: %s, max: %s).") \
% (config_filename, GAS_LIMITS_PROPERTY, limits, gas, SENSOR_RANGE_PPM[gas]['min'], SENSOR_RANGE_PPM[gas]['max'])
self.logger.critical(message)
critical_config_issues += [message]
if ((max(limits)*2) > SENSOR_RANGE_PPM[gas]['max']) :
# This is valid, but not optimal. Produce a warning.
message = ("%s : One or more of the '%s' configurations %s is very close to the range of the '%s' sensor (min: %s, max: %s)." +
"\nSensors shoud have a much larger range than the limits - e.g. 2x at a minimum .") \
% (config_filename, GAS_LIMITS_PROPERTY, limits, gas, SENSOR_RANGE_PPM[gas]['min'], SENSOR_RANGE_PPM[gas]['max'])
self.logger.warning(message)

# Check there's a valid definition of yellow - should be a percentage between 1 and 99
if not ( (self.YELLOW_WARNING_PERCENT > 0) and (self.YELLOW_WARNING_PERCENT < 100) ) :
Expand Down Expand Up @@ -319,7 +328,7 @@ def _calculate_TWA_and_gauge_for_all_firefighters(self, sensor_log_chunk_df, ff_

# It's essential to know when a sensor value can't be trusted - i.e. when it has exceeded its range (signalled
# by the value '-1'). When this happens, we need to replace that sensor's value with something that
# both 1. identifies it as untrustworthy and 2. also causes calculated values like TWAs and Gauges to be
# both (A) identifies it as untrustworthy and (B) also causes calculated values like TWAs and Gauges to be
# similarly identified. That value is infinity (np.inf). To to illustrate why: Say a firefighter experiences
# [30mins at 1ppm. Then 30mins at 25ppm] and the 1 hour limit is 10ppm. Then 1 hour into the fire, this
# firefighter has experienced an average of 13ppm per hour, well over the 10ppm limit - their status should be