# Standard Operating Procedure for the SCENES project measurement with the Compact setup and handling of equipment which is not recorded in another specific device-SOP
This SOP provides an overview of project-specific SCENES measurements with the compact setup.
| Project |SCENES |
|--------------|-----------------------------------------------------------|
| Objective | Describe the measurement procedure of the SCENES project with the compact setup |
| Owner | [Niloufar Tabandeh](mailto:[email protected]) |
| Version | _Start with 1.0.1_ |
| Last edit | 19.12.23 |
| Date | 19.12.23 |

## Day before measurement

#### Checklist: Make sure the following devices are fully charged.
1. Microsoft tablet
2. 2 GoPro Hero 10 batteries (black and white batteries)
3. Your cellphone


#### Checklist: Make sure the following devices, cables and materials are available
1. Intel RealSenseD455 depth camera + two screw + cable
2. GoPro Hero 10 + battery + microSD card + long black screw
3. Gigahertz Spectroradiometer + cable
4. Hard drive + USB 3.0 cable
5. Microsoft tablet + tablet charger
6. Testo temperature/humidity logger
7. Memory card reader + USB hub + USB-A to USB-C cable
8. Tripod + device holder


#### Checklist: Make sure the following procedures are completed
1. Connect the Microsoft tablet to the internet or manually change to the correct time zone in the tablet's settings.
2. Check if the Microsoft tablet is fully charged and has sufficient storage capacity.
3. Put the battery and microSD card inside the GoPro camera. Check that the battery and microSD capacity are sufficient.
4. Slide down on the GoPro's back screen. Time and date are shown. Then, slide left. In `preferences` section, open the general tab and scroll down to see the `Date` and `Time` tabs. Change them according to the current time zone.
5. Check that the Testo display shows "REC" for recording


## Day of measurement
_Start half an hour before the first scheduled measurement to creat folders based on convention, check devices and connection and prepare the metadata file_

### Pre-measurement procedure
#### Set up transportation to the location of measurement
1. Timelapse: Set the tripod and fix it at the desired position.
2. Trajectory: The devices must be dismounted after each measurement block and carried to different locations.

#### Setting up the equipment
1. Position the tripod securely at the desired position. Attach devices to the holder.
3. Attach the GoPro camera, Gigahertz spectroradiometer and Intel depth camera to their holders. Connect the Gigahertz spectroradiometer and Intel depth camera to the Microsoft tablet via cables and USB hub.
3. Turn on the Microsoft tablet and attach the USB hub.
4. Turn on the GoPro camera and open the `Quik app` on your cellphone to check their Bluetooth connection.

### Measurement procedures
1. Follow the device-specific SOPs to perform the measurements (LabHandbook/documentation/src/sops/light-measurement-devices/).
_All measurements from three devices automatically have been saved on the microSD card for the GoPro camera and on the Microsoft tablet for the Gigahertz spectroradiometer and Intel depth camera_
2. Complete all metadata entries on the Excel file After each measurement block.
a. Hold the cellphone with the compass app horizontally aligned with the GoPro and read out the direction the setup is facing (in degrees), the elevation (in m) and the position in coordinates (add them to the metadata).
b. Read out the temperature and humidity from the Testo device.

### Post-measurement procedures
1. After finishing the last measurement block, close all software. Check the saved files on the Document folder in the Microsoft tablet.
2. Turn off the Gigahertz spectroradiometer by holding a finger on the touch screen for 2 minutes.
3. Dismount the GoPro, depth camera and spectroradiometer from the holder.
4. Adding all relevant information to the metadata datasheets.
5. Connect the GoPro's microSD card to the tablet and copy all files with `.GPR`, `.mp4` and `.jpg` extensions and save them in the `GoPro` folder.
6. Copy and structure files based on the folder structure as an example folder. Do not rename the files; just copy them to the correct folders and delete any duplicated or mistaken files.
7. Make a copy of the structured measurement folder on the hard drive.


Original file line number Diff line number Diff line change
@@ -0,0 +1,95 @@
# Standard Operating Procedure for the SCENES project measurement with the Full setup and handling of equipment which is not recorded in another specific device-SOP
This SOP provides an overview of project-specific SCENES measurements.
| Project |SCENES |
|--------------|-----------------------------------------------------------|
| Objective | Describe the measurement procedure of the SCENES project |
| Owner | [Niloufar Tabandeh](mailto:[email protected]) |
| Contributors | [Alexander Hahn](mailto:[email protected]) |
| Version | _Start with 1.0.1_ |
| Last edit | 11.06.23 |
| Date | 07.05.23 |

## Day before measurement

#### Checklist: Make sure the following devices are fully charged. Do not let the devices charge throughout the entire night to prevent battery damage!
1. Laptop
2. Tablet
3. Four external Makita batteries
4. 2 GoPro Hero 10 batteries (black and white batteries)


#### Checklist: Make sure the following devices, cables and materials are in the shell-backpack
1. Intel RealSenseD455 depth camera + brass screw
2. GoPro Hero 10 + battery + 512 Gb microSD-card + long black screw
3. Hard-Drive + USB 3.0 cable
4. mini-USB cable (for Testo 175 H1)
5. Laptop charger
6. WP690 power cable
7. Jeti diffusor
8. micro-USB-cables for Acttrusts


#### Checklist: Make sure the following devices, cables and accessories are in/on the black box
1. Circadiometer WP690 with attached lens cover
2. Spectroradiometer Jeti 1511 with attached lens cover (orientated in the correct direction. The orientation of the mounting can be changed by loosening the large brass screw on the device
3. Colorimeter Klein K10-A
4. Temperature/Humidity logger Testo 175 H1 (mounting on the back of the box)
5. USB-C-cable (for Depth camera)


#### Checklist: Make sure the following procedures are completed
1. Devices on the rail inside the black box should be put in the back position (so closing the front lid does not cause damage to the devices)
2. The white lid for the front opening of the black box is attached with all four hinges
3. The two Actigraphs, their two data-transfer-casings, their two measurement-casings and a thin screwdriver are put on the table next to the (charged) laptop
4. Put the charged Makita batteries in the battery backpack
5. The Testo display says "REC" for recording
6. Optional: If you plan to do measurements where power is available, prepare a sufficient extension cable and a multiple power socket
&rarr Additional device-specific procedures are included in the device SOPs (Templates/documentation/src/sops/light_measurement_devices)


## Day of measurement
_Come in the office 30-45 minutes before the planned first measurement_

### Pre-measurement procedure
#### Actigraph preparation
1. Use the screwdriver to put the two Actigraphs in the data-transfer-casings (old/white & new/white)
2. Turn on the laptop and start the Acttrust software
3. Attach the first data-transfer-casings to the laptop using the micro-USB cable.
4. If the reading in the software says "ACTIVE", the device is activated. It can now be put in the measurement casing using the screwdriver.
5. Repeat steps 3 & 4 with the respective other Actigraph
6. Put the Actigraphs in their measurement-casings in the shell-backpack

#### Setup preparation
1. Put the laptop and tablet in the shell backpack
2. Wind up the cable bundle and put it inside the black box
3. Close the upper lid of the black box

#### Set up transportation to the location of measurement
1. Timelapse: Attach the black box and the tripod to the silver transportation trolly. Pull out its handle at the bottom by pressing the button on the top of the handle. Be careful when pulling the trolley not to lose balance! You need two operators to carry the battery backpack and the shell backpack. Also, from September 2023, we have a trolly attached to the black box for easy transportation.
2. Trajectory: Carry the black box, tripod and battery backpack to the car used for transportation and load them carefully in safe and stable positions.

#### Setting up the equipment
1. Position the tripod securely at the desired position so that the wide opening of the mounting faces the direction that you want to measure. Use the large handle underneath the mounting to elevate the mount to the desired position. Fixate all screws on the legs of the tripod to increase stability.
2. Open the steel handle at the bottom of the tripod mounting and carefully insert the base of the black box into the mount. Afterward, close the steel handle again to secure the black box in the mount.
3. Hold your device with the compass app horizontally against the black box and read out the direction the box is facing (in degrees), the elevation (in m) and the position in coordinates (iPhone smartphones allow this with the integrated app "Compass").
3. Attach the GoPro and the Depth camera to their mountings. Also, attach the two Actigraphs in their measurement-casings on the steel plate at the front of the black box using the magnets.
3. Turn on the laptop and attach the USB hub.
4. Open the upper lid of the black box and insert the micro-USB cable in its socket in the Jeti. Also, attach the magnet on the cable to the steel plate behind the Jeti.
5. Detach the white lid on the front of the black box and pull the rail for the devices in the forward position.
6. Unroll the cable bundle and attach the USB cables (WP690 directly to the laptop and the others to the USB hub (also connect the hard drive to the USB hub).
7. If power is available, use the WP690 power cable. If not, attach the WP690 cable from the cable bundle to the battery backpack. Insert the other end of the cable into the WP690 (if you use the power cable, tighten the thread for one rotation).

### Measurement procedures
1. Follow the device-specific SOPs to perform the measurements (LabHandbook/documentation/src/sops/light-measurement-devices/).
2. After every measurement, create a new record in the project _SCENES_ in the REDCap mobile APP (Username: Chrono_redcap; PW: _for this info, ask Alexander Hahn or Niloufar Tabdandehsaravi_) to properly maintain the metadata.

### Post-measurement procedures
1. After finishing the last measurement, shut down all software/instruments and make sure the data is saved. Do all this according to the device-specific SOPs!
2. Attach the lens protection to WP690 and Jeti (after taking the lens off Jeti).
3. Remove the GoPro, Depth camera and Actigraphs from the black box and put them in the shell backpack.
4. Wind up the cables (about a forearm-length in diameter) and put them inside the black box.
5. Transport the setup back to the office. Orientate yourself on the subpoint "Setup transportation to the measurement location".
6. Data saving from the devices Testo, GoPro and Actigraphs should be done according to the device-specific SOPs.