Merge pull request #127 from REAM-lab/database/transmission_fix
Browse files Browse the repository at this point in the history
Script to fix derating factor for transmission lines
  • Loading branch information
jszinai authored and staadecker committed Jan 29, 2023
2 parents 2921d7a + 0f435df commit b73e37f
Show file tree
Hide file tree
Showing 3 changed files with 106 additions and 12 deletions.
78 changes: 78 additions & 0 deletions database/2022-10-12_Transmission_scenario_fix.sql
Original file line number Diff line number Diff line change
@@ -0,0 +1,78 @@
-- October 12, 2022
-- Author: pesap

-- Reason: We detected a type in the transmission derating factor for all the transmission
-- lines for the WECC model. This is the description in the switch module of what the
-- transmission derate factor does: trans_derating_factor[tx in TRANSMISSION_LINES] is an
-- overall derating factor for each transmission line that can reflect forced outage
-- rates, stability or contingency limitations. This parameter is optional and defaults to
-- 1. This parameter should be in the range of 0 to 1, being 0 a value that disables the
-- line completely.
-- In our scenarios we have been using 0.59 for no apparent reason and this limited the
-- amount of electricity that flow throught the transmission line. The new value that we
-- will use for the scenarios is 0.95 or a 5% derate.

alter table
switch.transmission_lines
add
column transmission_scenario_id int;

alter table
switch.scenario
add
column transmission_scenario_id int;

UPDATE switch.transmission_lines SET transmission_scenario_id = 1;
UPDATE switch.scenario SET transmission_scenario_id = 1;

alter table switch.transmission_lines drop constraint transmission_lines_pkey;

insert into switch.transmission_lines(
transmission_line_id, start_load_zone_id,
end_load_zone_id, trans_length_km,
trans_efficiency, existing_trans_cap_mw,
new_build_allowed, derating_factor,
terrain_multiplier, transmission_cost_econ_multiplier,
transmission_scenario_id
)
select
transmission_line_id,
start_load_zone_id,
end_load_zone_id,
trans_length_km,
trans_efficiency,
existing_trans_cap_mw,
new_build_allowed,
0.95 as derating_factor,
terrain_multiplier,
transmission_cost_econ_multiplier,
2 as transmission_scenario_id
from
switch.transmission_lines;

insert into switch.scenario
values (179,
'[LDES and SWITCH_WEAP]',
'Baseline scenario with 0 carbon cap for WECC and CA by 2045, 15% PRM, updated 2 days per month sampling and tranmission_line scenario',
17, -- study_timeframe_id
16, -- time_sample_id
115, -- demand_scenario_id
4, -- fuel_simple_price_scenario, without Bio_Solid costs, because they are provided by supply curve
23, -- generation_plant_scenario_id
25, -- generation_plant_cost_scenario_id
21, -- generation_plant_existing_and_planned_scenario_id
23, -- hydro_simple_scenario_id
92, -- carbon_cap_scenario_id
2, -- supply_curve_scenario_id
1, -- regional_fuel_market_scenario_id
NULL, -- rps_scenario_id
NULL, --enable_dr
NULL, --enable_ev
2, --transmission_base_capital_cost_scenario_id
NULL, --ca_policies_scenario_id
1, --enable_planning_reserves
2, --generation_plant_technologies_scenario_id
3, --variable_o_m_cost_scenario_id
NULL,--wind_to_solar_ratio
2 --tranmission_scenario_id
);
39 changes: 27 additions & 12 deletions switch_model/wecc/get_inputs/get_inputs.py
Original file line number Diff line number Diff line change
Expand Up @@ -315,16 +315,32 @@ def query_db(config, skip_cf):
"trans_terrain_multiplier",
"trans_new_build_allowed",
],
"""
SELECT start_load_zone_id || '-' || end_load_zone_id, t1.name, t2.name,
trans_length_km, trans_efficiency, existing_trans_cap_mw, transmission_line_id,
derating_factor, terrain_multiplier * transmission_cost_econ_multiplier as terrain_multiplier,
new_build_allowed
FROM transmission_lines
join load_zone as t1 on(t1.load_zone_id=start_load_zone_id)
join load_zone as t2 on(t2.load_zone_id=end_load_zone_id)
WHERE start_load_zone_id < end_load_zone_id
ORDER BY 2,3;
f"""
SELECT
start_load_zone_id || '-' || end_load_zone_id,
t1.name,
t2.name,
trans_length_km,
trans_efficiency,
existing_trans_cap_mw,
transmission_line_id,
derating_factor,
terrain_multiplier * transmission_cost_econ_multiplier as terrain_multiplier,
new_build_allowed
FROM
switch.transmission_lines
join switch.load_zone as t1 on(
t1.load_zone_id = start_load_zone_id
)
join switch.load_zone as t2 on(
t2.load_zone_id = end_load_zone_id
)
WHERE
start_load_zone_id < end_load_zone_id and
transmission_scenario_id = {params.transmission_scenario_id}
ORDER BY
2,
3;
""",
)

Expand All @@ -337,10 +353,9 @@ def query_db(config, skip_cf):
"trans_lifetime_yrs",
"trans_fixed_om_fraction",
],
# See Issue #80 for reasoning behind the 85 year lifetime.
f"""
SELECT trans_capital_cost_per_mw_km,
85 as trans_lifetime_yrs,
25 as trans_lifetime_yrs,
0.03 as trans_fixed_om_fraction
FROM transmission_base_capital_cost
WHERE transmission_base_capital_cost_scenario_id = {params.transmission_base_capital_cost_scenario_id}
Expand Down
1 change: 1 addition & 0 deletions switch_model/wecc/get_inputs/scenario.py
Original file line number Diff line number Diff line change
Expand Up @@ -25,6 +25,7 @@ def __init__(self, scenario_id=None):
self.generation_plant_technologies_scenario_id = None
self.variable_o_m_cost_scenario_id = None
self.wind_to_solar_ratio = None
self.transmission_scenario_id = None


def load_scenario_from_config(config, db_cursor) -> ScenarioParams:
Expand Down