Skip to content

Commit

Permalink
Add watchdog to error LED flashes and use highest of the 3 temp sensors
Browse files Browse the repository at this point in the history
  • Loading branch information
stuartpittaway committed Dec 27, 2023
1 parent f3f825a commit db0e666
Showing 1 changed file with 8 additions and 0 deletions.
8 changes: 8 additions & 0 deletions STM32All-In-One/src/main.cpp
Original file line number Diff line number Diff line change
Expand Up @@ -733,6 +733,7 @@ void TakeOnboardInternalTempMeasurements(CellData &cd)

// Spread the two internal temperature sensor values across all 16 cells (even though some may not be connected)
// Odd cells are on the left of the balance board, near TH1/T1, even on right side TH2/T2
// but this doesn't matter, as we use the highest recorded temperature from either sensor in safety checks
for (size_t i = 0; i < 16; i += 2)
{
cd.at(i).setInternalTemperature(t1);
Expand Down Expand Up @@ -763,6 +764,9 @@ void TakeOnboardInternalTempMeasurements(CellData &cd)
delay(500);
while (true)
{
// make sure the code in this loop is executed in less than 2 seconds to leave 50% headroom for the timer reload.
IWatchdog.reload();

for (size_t i = 0; i < number; i++)
{
NotificationLedOn();
Expand All @@ -771,6 +775,8 @@ void TakeOnboardInternalTempMeasurements(CellData &cd)
delay(220);
}

// make sure the code in this loop is executed in less than 2 seconds to leave 50% headroom for the timer reload.
IWatchdog.reload();
delay(2000);
}
}
Expand Down Expand Up @@ -1029,7 +1035,9 @@ void loop()
// Now process the ADC readings we have taken...
DecimateRawADCCellVoltage(rawADC, celldata, number_of_active_cells);

// Three temperature sensors are recorded over cells 0/1/2, use the highest value
auto highestTemp = max(celldata.at(0).getInternalTemperature(), celldata.at(1).getInternalTemperature());
highestTemp = max(celldata.at(2).getInternalTemperature(), highestTemp);

// If fan timer has expired, switch off FAN
// This has the side effect of the fan switching off and on (not physically noticable) should the temperature still be too hot.
Expand Down

0 comments on commit db0e666