Notifications
You must be signed in to change notification settings - Fork 5
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
- Loading branch information
Showing
2 changed files
with
97 additions
and
1 deletion.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -1,5 +1,5 @@ | ||
--- | ||
sidebar_position: 6 | ||
sidebar_position: 5 | ||
--- | ||
# Setting Your Gateway Location | ||
|
||
|
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,96 @@ | ||
--- | ||
sidebar_position: 6 | ||
--- | ||
|
||
# Inverter Setup Guide | ||
|
||
## Overview | ||
|
||
The inverter setup is a crucial step that enables your gateway to communicate with your solar inverter. This connection allows for: | ||
- Real-time power production monitoring | ||
- Performance analytics | ||
- Energy production verification | ||
- System health monitoring | ||
|
||
## Connection Methods | ||
|
||
### 1. Direct Connection (Modbus TCP) | ||
- Most modern inverters support this method | ||
- Uses standard Ethernet/WiFi connection | ||
- Requires inverter's IP address and port | ||
- Default port is usually 502 | ||
|
||
### 2. Via RS485-to-Ethernet Converter | ||
- For inverters with only RS485 (Modbus RTU) support | ||
- Requires additional hardware | ||
- Converts serial communication to network protocol | ||
- Maintains compatibility with older inverters | ||
|
||
### 3. Via Modbus TCP Proxy | ||
- For inverters limited to single connections | ||
- Allows multiple devices to connect | ||
- Maintains existing monitoring setup | ||
- Requires proxy configuration | ||
|
||
## Setup Instructions | ||
|
||
1. **Select Your Inverter** | ||
- Choose your inverter manufacturer from the list | ||
- If not listed, check compatibility documentation | ||
- Note: New inverters are regularly added | ||
|
||
2. **Connection Details** | ||
- Enter the inverter's IP address | ||
- Verify the port number (usually 502) | ||
- Set the device address (typically 1) | ||
- Test connection before saving | ||
|
||
3. **Configuration Verification** | ||
- System will test the connection | ||
- Verify data is being received | ||
- Check for any communication errors | ||
- Confirm proper readings | ||
|
||
## Common Settings | ||
|
||
### Default Ports | ||
- Modbus TCP: 502 | ||
- SunSpec: 502 | ||
- Custom: Check inverter manual | ||
|
||
### Device Addresses | ||
- Single inverter: Usually 1 | ||
- Multiple inverters: 1-247 | ||
- Check inverter documentation | ||
|
||
## Troubleshooting | ||
|
||
### Can't Find Inverter | ||
- Verify inverter is powered on | ||
- Check network connection | ||
- Ensure you're on the same network | ||
- Try scanning for devices again | ||
|
||
### Connection Failed | ||
- Verify IP address and port | ||
- Check firewall settings | ||
- Confirm inverter settings | ||
- Try power cycling the inverter | ||
|
||
### Data Not Updating | ||
- Check connection stability | ||
- Verify device address | ||
- Ensure proper protocol selection | ||
- Review inverter configuration | ||
|
||
## Need More Help? | ||
|
||
If you: | ||
- Don't see your inverter listed | ||
- Can't establish connection | ||
- Need technical assistance | ||
- Have compatibility questions | ||
|
||
Contact our support team through Discord or email. | ||
|
||
> Note: Keep your inverter manual handy during setup. Some manufacturers have specific requirements or settings that need to be enabled. |