Add support for DT5 (0-10V conversion) devices
Tested with Lunatone 86458508-AN. This one only appears to support switching between linear and logarithmic dimming curves, and some (undocumented) manufacturer's extensions. Support for pullup handling as well as switching between the 0-10V and 1-10V ranges is not there.
- Loading branch information
Showing
3 changed files
with
185 additions
and
2 deletions.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,172 @@ | ||
"""Commands and responses from IEC 62386 part 206. | ||
This part convers conversion from digital signal into DC voltage. | ||
""" | ||
|
||
from dali import command | ||
from dali.gear.general import _StandardCommand, QueryExtendedVersionNumberMixin | ||
|
||
|
||
class _ConversionCommand(_StandardCommand): | ||
devicetype = 5 | ||
|
||
|
||
class _ConversionConfigCommand(_ConversionCommand): | ||
"""An incandescent lighting configuration command as defined in | ||
section 11.3.4.1 of IEC 62386-206:2009. | ||
""" | ||
sendtwice = True | ||
|
||
|
||
############################################################################### | ||
# Commands from IEC 62386-206 section 11.3.4.1 | ||
############################################################################### | ||
|
||
class SetOutputRange1To10V(_ConversionConfigCommand): | ||
"""Set the output range to 1V - 10V | ||
Converters without this feature shall not react. | ||
""" | ||
_cmdval = 224 | ||
|
||
|
||
class SetOutputRange0To10V(_ConversionConfigCommand): | ||
"""Set the output range to 0V - 10V | ||
Converters without this feature shall not react. | ||
""" | ||
_cmdval = 225 | ||
|
||
|
||
class SwitchOnInternalPullUp(_ConversionConfigCommand): | ||
"""Switch on the internal pull-up resistor at the control voltage output | ||
Converters without this feature shall not react. | ||
""" | ||
_cmdval = 226 | ||
|
||
|
||
class SwitchOffInternalPullUp(_ConversionConfigCommand): | ||
"""Switch off the internal pull-up resistor at the control voltage output | ||
Converters without this feature shall not react. | ||
""" | ||
_cmdval = 227 | ||
|
||
|
||
class StoreDtrAsPhysicalMinimum(_ConversionConfigCommand): | ||
"""The physical minimum level shall be changed to the value given in the DTR""" | ||
_cmdval = 228 | ||
|
||
|
||
class SelectDimmingCurve(_ConversionConfigCommand): | ||
"""Select Dimming Curve | ||
If DTR0 is 0 then selects the standard logarithmic curve | ||
If DTR0 is 1 then selects a linear dimming curve | ||
Other values of DTR0 are reserved and will not change the dimming | ||
curve. The setting is stored in non-volatile memory and is not | ||
cleared by the Reset command. | ||
""" | ||
_cmdval = 229 | ||
|
||
|
||
class ResetConverterSettings(_ConversionConfigCommand): | ||
"""Reset parameters which are not affected by RESET | ||
All converter settings not influenced by the RESET command shall be set to the | ||
default values given in clause 10 of IEC 62386-206:2009. | ||
""" | ||
_cmdval = 230 | ||
|
||
|
||
############################################################################### | ||
# Commands from IEC 62386-205 section 11.3.4.2 | ||
############################################################################### | ||
|
||
class QueryDimmingCurve(_ConversionCommand): | ||
"""Query Dimming Curve | ||
0 = standard logarithmic | ||
1 = linear | ||
2-255 = reserved for future use | ||
""" | ||
_cmdval = 238 | ||
response = command.Response | ||
|
||
class OutputLevelResponse(command.NumericResponse): | ||
def __str__(self): | ||
if isinstance(self.value, int): | ||
if self.value == 254: | ||
return "10.16V or more" | ||
elif self.value == 255: | ||
return "unknown" | ||
else: | ||
return f"{self.value * 0.04} V" | ||
return self.value | ||
|
||
|
||
class QueryOutputLevel(_ConversionCommand): | ||
"""Query the output level | ||
The answer shall be the analog output level in units of 0.04V, fiving a range of 0V to 10.16V. | ||
Raw value 254 maps to 10.16V or higher. | ||
Raw value of 255 means "the output level is not known". | ||
Converters without this feature shall not react. | ||
""" | ||
_cmdval = 239 | ||
response = OutputLevelResponse | ||
|
||
|
||
class QueryConverterFeaturesResponse(command.BitmapResponse): | ||
bits = [ | ||
"0V - 10V output selectable", | ||
"internal pull-up selectable", | ||
"detection of output fault selectable", | ||
"mains relay", | ||
"output level can be queried", | ||
"non-logarithmic dimming curve supported", | ||
"physical selection / lamp fail detection by loss out output supported", | ||
"physical selection switch supported", | ||
] | ||
|
||
|
||
class QueryConverterFeatures(_ConversionCommand): | ||
"""Query hardware features of the converter""" | ||
_cmdval = 240 | ||
response = QueryConverterFeaturesResponse | ||
|
||
|
||
class QueryFailureStatusResponse(command.BitmapResponse): | ||
bits = [ | ||
"output fault detected", | ||
] | ||
|
||
|
||
class QueryFailureStatus(_ConversionCommand): | ||
"""Query failure status register""" | ||
_cmdval = 241 | ||
response = QueryFailureStatusResponse | ||
|
||
|
||
class QueryConverterStatusResponse(command.BitmapResponse): | ||
bits = [ | ||
"0-10V operation", | ||
"internal pull-up on", | ||
"non-logarithmic dimming curve active", | ||
] | ||
|
||
|
||
class QueryConverterStatus(_ConversionCommand): | ||
"""Query the current status of the converter""" | ||
_cmdval = 242 | ||
response = QueryConverterStatusResponse | ||
|
||
|
||
class QueryExtendedVersionNumber(QueryExtendedVersionNumberMixin, | ||
_ConversionCommand): | ||
pass |