iCubErzelli01 S/N:032 – Fingers on the left-arm not working properly #1710

Closed
ddetommaso opened this issue Jan 16, 2024 · 8 comments
Closed

Comments

@ddetommaso
Copy link

Robot Name πŸ€–

iCubErzelli01 S/N:032

Request/Failure description

We have encountered issues on fingers of the left-arm, specifically related to thumb and pinky joints.

Detailed context

During calibration the fingers often get stuck.
Moreover, even when the calibration is successful, the little fingers are not moving from yarpmotorgui the interface (motor and encoders seem fine).

Additional context

log_icub-head_yarprobotinterface_3025.zip

image

robot.mp4

How does it affect you?

High impact. The robot is currently in use for an experimental protocol and we needed to cancel participants.

@github-actions github-actions bot changed the title Fingers on the left-arm not working properly iCubErzelli01 S/N:032 – Fingers on the left-arm not working properly Jan 16, 2024
@sgiraz sgiraz moved this from Triage to In Progress in iCub Tech Support Jan 18, 2024
@AntonioConsilvio AntonioConsilvio moved this from In Progress to Triage in iCub Tech Support Jan 18, 2024
@AntonioConsilvio
Copy link
Contributor

AntonioConsilvio commented Jan 19, 2024

Hi @ddetommaso, a quick test. The solution may be simpler than expected.
Specifically it is to make sure the configuration files are aligned on this robots-configuration master commit:

In particular, this PR had originated from the last intervention performed to iCuberzelli01 (see issue).

Let us know as soon as you can!

cc @sgiraz

@sgiraz sgiraz moved this from Triage to Backlog in iCub Tech Support Jan 19, 2024
@sgiraz sgiraz moved this from Backlog to In Progress in iCub Tech Support Jan 19, 2024
@ddetommaso
Copy link
Author

Hi @AntonioConsilvio

I can confirm that the configuration files are correctly aligned with the ones in the PR.
The pinky fingers are still not correctly working, probably there is a calibration issu.

@sgiraz
Copy link
Contributor

sgiraz commented Jan 23, 2024

Hi @ddetommaso,

The maintenance activity is scheduled for tomorrow!

cc @GiacomoVassallo13 @AntonioConsilvio

@AntonioConsilvio
Copy link
Contributor

Hi @ddetommaso. Yesterday me and @GiacomoVassallo13, after several tests, found the flat cable that connect the pinky motor the MC4-PLUS EB26 damaged.
So, we cut off most of the damaged flat and soldered a new one.

The robot seemed to works properly! But we are waiting for feedback before proceeding with closing the issue.

We also found once that the thumb distal was not calibrating, but the problem was solved by restarting the motors. For now talking with @ddetommaso it was considered a non-urgent or blocking issue, so it was agreed not to investigate further for now.

cc @sgiraz

@AntonioConsilvio AntonioConsilvio moved this from In Progress to Review/QA in iCub Tech Support Jan 25, 2024
@sgiraz
Copy link
Contributor

sgiraz commented Jan 29, 2024

Hi @ddetommaso,

Do you have any feedback to share w/ us?

@ddetommaso
Copy link
Author

Hi @sgiraz

I am still waiting to provide our feedback for a couple of days of testing.

Thank you

@ddetommaso
Copy link
Author

Hi guys,

we can close this. The issue with the pinky is fixed

@sgiraz
Copy link
Contributor

sgiraz commented Feb 2, 2024

Thanks for your feedback @ddetommaso.

Closing!

@sgiraz sgiraz closed this as completed Feb 2, 2024
@github-project-automation github-project-automation bot moved this from Review/QA to Done in iCub Tech Support Feb 2, 2024