This page gives some example commands for controlling your Faikin device using simple HTTP GET web requests.

Substitute 192.168.1.101 for the IP address of your device.

Alternative you can use the hostname such as f412fa97cde8.local

Turn Air Conditioner unit on and off

Send the pow command with 1

192.168.1.101/aircon/set_control_info?pow=1

Send the pow command with 0

192.168.1.101/aircon/set_control_info?pow=0

Set the target / desired temperature

Send the stemp command

192.168.1.101/aircon/set_control_info?stemp=23

Set the HVAC mode

Send the mode command

192.168.1.101/aircon/set_control_info?mode=1&pow=1

Set the fan speed

Send the f_rate command

A=Auto

B=night

3=1

4=2

5=3

6=4

7=5

192.168.1.101/aircon/set_control_info?f_rate=A

Endpoints

Additional API endpoints:

  • /common/basic_info
  • /aircon/get_sensor_info
  • /aircon/get_control_info