gh #44 Update hdmi-cec-sink-L3-Low-Level_TestSpec.md
Browse files Browse the repository at this point in the history
enhancement to the sequence diagram
  • Loading branch information
srinivasgtl committed Aug 6, 2024
1 parent eb5c542 commit a77a0b6
Showing 1 changed file with 8 additions and 0 deletions.
8 changes: 8 additions & 0 deletions docs/pages/hdmi-cec-sink-L3-Low-Level_TestSpec.md
Original file line number Diff line number Diff line change
Expand Up @@ -132,20 +132,25 @@ sequenceDiagram
CEC Adaptor->>DUT: Send "GetCECVersion" before adding the logical address
RAFT/user->>RAFT/user: No response or ack should be received.
DUT->>DUT: Wait for the RAFT/user to signal to provide ack received or not.
RAFT/user->>DUT: RAFT/user to signal the test to move ahead
DUT->>DUT: Check no RxCallback has been received and decide whether the test passes or fails
DUT->>DUT: Add Logical Address
DUT->>DUT: Wait for User/RAFT to enter the logical address
RAFT/user->>DUT: RAFT/user to provide the logical address
DUT->>CEC Adaptor: Send "GetCECVersion"
CEC Adaptor->>DUT: Send the "CEC Version"
DUT->>DUT: Validate CEC Version
DUT->>DUT: Wait for User/RAFT to signal the start of the next test
RAFT/user->>DUT: RAFT/user to signal the test to move ahead
RAFT/user->>CEC Adaptor: Command to send CEC OSD Command
CEC Adaptor->>DUT: Send CEC OSD Command
DUT->>DUT: Validate the received command
RAFT/user->>RAFT/user: Read the CEC acknowledgment received and validate
DUT->>DUT: Wait for User/RAFT to enter the acknowledgment confirmation and decide Test Pass/Fail
RAFT/user->>DUT: RAFT/user to provide the test result
CEC Adaptor->>DUT: Send "GetCECVersion" to an LA other than `DUT`(0x01 to 0x0E). Repeat these 4 steps for all the addresses sent.
DUT->>DUT: Wait for User/RAFT to signal when the CEC adaptor has sent a CEC message.
RAFT/user->>DUT: RAFT/user to signal the test to move ahead
DUT->>DUT: Test fails if it has received any message.
RAFT/user->>RAFT/user: No CEC acknowledgment is received after CEC Frames are sent.
```
Expand Down Expand Up @@ -217,6 +222,7 @@ sequenceDiagram
DUT->>DUT: Wait for the input from RAFT/user to provide the test result
RAFT/user->>DUT: Provide the Test result of standby data received by it.
DUT->>DUT: Wait for the input from RAFT/user to send a broadcast command
RAFT/user->>DUT: RAFT/user to signal the test to move ahead
RAFT->>CEC Adaptor: Broadcast "standby" command
RAFT/user->>DUT: Signal the command to validate the data RAFT/user broadcasted and received by DUT.
CEC Adaptor->> DUT: Broadcast the standby command
Expand Down Expand Up @@ -285,9 +291,11 @@ sequenceDiagram
RAFT/user->>RAFT/user: To validate the acknowledgment received each time when sent the CEC Frame.
DUT-->>DUT: Validate the received command for 10 times
RAFT/user->>DUT: DUT to wait till the RAFT/user provides the data ack result
RAFT/user->>DUT: RAFT/user to signal the test to move ahead with the ack result
DUT->>CEC Adaptor: Send CEC OSD Command for 10 times
RAFT/user->>RAFT/user: To validate the OSD Command received on the CEC Adaptor
RAFT/user->>DUT: DUT to wait till the RAFT/user provides the data ack result
RAFT/user->>DUT: RAFT/user to signal the test with result
DUT->>DUT: To decide the final result based on the RAFT/user result and its own result.
```