Even with a limited number of building prototypes, urban building energy modeling (UBEM) has to consider the microclimates in the region, as the urban heat island effect and the heterogeneous geographical characteristics have an obvious impact on building energy performances. The number of simulations needed for UBEM is therefore large, and the computation time could be days long. Surrogate modeling is a promising way to reduce the computation time. This repo contains the codes for training surrogate models based on the annual simulation results in selected microclimates and using the models for UBEM with other microclimates.
Download the dataset from Google Drive
and name it as data
in the root dir of the project.
Please refer to the work by Xu et. al.
for the explanation of the datasets.
Create a dir ./saved/estimates_tracts
in the root dir of the project.
Running run_geoVis.py
requires the mapping service of MapBox.
Please create mapbox_token.txt
in ./utils
, which contains the mapbox token in one line.
Mapbox account is required to obtain the token. An example of
mapbox token is pk.eyJ1IjoicH***********1NXo0M3A5bj*****.f384XN*****
.
Edit the config.py
to configure the training and estimation.
features
: a list of string. Supports inputs including
'GLW'
, 'PSFC'
, 'Q2'
, 'RH'
, 'SWDOWN'
, 'T2'
, 'WINDD'
, 'WINDS'
,
and 'Typical' + target_buildingLevel
.
target_tractLevel
: string. Supports inputs in the Short Name
column of the following table.
target_buildingLevel
: string. Supports inputs in the Full Name
column of the following table.
Short Name | Full Name |
---|---|
emission.surf | Environment:Site Total Surface Heat Emission to Air [J](Hourly) |
emission.exfiltration | Environment:Site Total Zone Exfiltration Heat Loss [J](Hourly) |
emission.exhaust | Environment:Site Total Zone Exhaust Air Heat Loss [J](Hourly) |
emission.ref | SimHVAC:Air System Relief Air Total Heat Loss Energy [J](Hourly) |
emission.rej | SimHVAC:HVAC System Total Heat Rejection Energy [J](Hourly) |
energy.elec | Electricity:Facility [J](Hourly) |
energy.gas | NaturalGas:Facility [J](Hourly) |
lag
: list of int. The index of time lags in each sequence, ranging from 1.
For example, in the case of using 4 time lags to estimate 1 timestamp forward with 'LSTM'
,
lag
should be [1, 2, 3, 4]
. In the case of using 2 timestamps both in the past
and future to estimate the timestamp in the middle with 'biLSTM'
, also use
[1, 2, 3, 4]
. Please note if 'biLSTM'
is used, the length of lag
must be
an even number.
modelName
: string. Supports 'naive'
, 'LSTM'
, 'biRNN'
, 'linear'
,
'mlp'
, and biRNN_global
.
tuneTrail
: int. Number of trails in hyperparameter tuning. Only works
for 'LSTM'
and 'biLSTM'
. If set as 1, hyperparameter tuning is disabled.
maxEpoch
: int. Max epoch count for 'LSTM'
and 'biLSTM'
training.
saveFolderHead
: string. Recommend name it using the target_tractLevel
and the modelName
. For example, energyElec_biLSTM
stands for the experiment
using 'biLSTM'
for estimating 'energy.elec'
.
randomSeed
: int. The random seed used by numpy.random.
testDataPer
: float, 0-1, only works for the "Option 2" in the run.py
.
The percentage of microclimates used for training.
dirTargetYear
: None
or list, only works for the "Option 1" in the run.py
.
In default, dirTargetYear
is set as None
. In this case, the microclimates zones
in the 2018 is split into training and testing set. However, in real use case, the trained
model will estimate the targets in another year. For this purpose, dirTargetYear
should be set as a
list, indicating the dir of input features and ground truth (if any) for test.
The first element is the dir of energy data. The second is for weather data. The third is
for typical target values. The last one is the tract level ground truth. Example for estimating 2016 whole year:
[
'./data/hourly_heat_energy/sim_result_ann_WRF_2016_csv',
'./data/weather input/2016',
'./data/testrun',
'./data/hourly_heat_energy/annual_2016_tract.csv'
]
dayOfWeekJan1
: int. The day of week of the target year of estimation. 1 incicates Monday and 7 indicates
Sunday.
After configure and run the program, a folder that contains all the outputs for
this run will be generated under ./saved/estimates_tracts
. The output folder
is named with target_model_notes_experimentTime
.
For example, energyElec_biLSTM_GPU-V100_2023-07-21-21-39-29
is the output folder for estimating electricity with bi-directional LSTM at
21:39:29 07/21 2023 with V100 GPU for training (available targets and model names are introduced below).
pairListTest.json
and pairListTrain.json
contains the prototype-weather
pairs
used for test and training.
The buildingLevel
folder under the ./saved/estimates_tracts/target_model_experimentTime
contains
the intermediate result. Each .csv
file contains the hourly estimation of the
target at the building prototype level.
tractsDF.csv
is the estimation of the target at the census tract level.
config.py
shows the configuration of this experiment, and other files in the
./saved/estimates_tracts/target_model_experimentTime
folder are used for
the evaluation and visualization of the estimations.
Required packages:
- tensorflow 2
- keras-tuner
- numpy
- pandas
- geopandas
- statesmodel
- scipy
- scikit-learn
- matplotlib
- plotly
Running:
python run.py
The repo is tested on a NVIDIA V100 GPU, the running using the default config in this repo can be finished within approximately 1.5 hours.
-
The typical values of the target is used as a feature. The typical values is obtained by using simulations for 2018 at LA airport. 2018 starts from Monday. If the year to be estimated does not start from Monday, there will be a shift between estimation and ground truth for some building types. So, the day of week on Jan 1 for target year is a required parameter, which will be introduced on the Configuration section. But Please note the day of week on Jan 1 for training data is hard coded as
1
. Please change it in the files under./model
to revise that if the typical value data is changed. -
2001 is hard coded in the whole program as the default year. Please update the year according to the context.
-
Training and testing using all prototypes is very time-consuming for debug purposes.
pairListTrain
andpairListTest
could be re-written to specify the prototype-microclimate pairs used in training and testing. For example:pairListTrain = pairListTrain[0:1] pairListTest = pairListTest[0:1]
-
Global estimation means using one single model to do the estimation for all prototypes. It is expected to generate better accuracy in some cases, because different prototypes share part of the data generation process, and it works as a simple multitasks learning architecture. Set
modelName = 'biLSTM_global'
will open this option. However, the option was not fully developed and the size of training dataset is large. The total size of training and validationnumpy
array withfloat32
type is about 25GB.
run_preAnalysis.py
conducts preliminary analysis (e.g., visualization, autocorelation plot)
on the raw data.
run_resumeEval.py
are kept for debugging and customization purposes. It reloads the saved estimations
for evaluations.
run_geoVis.py