Notifications
You must be signed in to change notification settings - Fork 500
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
- Loading branch information
Showing
2 changed files
with
344 additions
and
0 deletions.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,343 @@ | ||
# coding=utf-8 | ||
# | ||
# pwm_mqtt.py - Output for publishing PWM via MQTT | ||
# | ||
import copy | ||
|
||
from flask_babel import lazy_gettext | ||
from sqlalchemy import and_ | ||
|
||
from mycodo.databases.models import DeviceMeasurements | ||
from mycodo.databases.models import OutputChannel | ||
from mycodo.outputs.base_output import AbstractOutput | ||
from mycodo.utils.constraints_pass import constraints_pass_positive_or_zero_value | ||
from mycodo.utils.database import db_retrieve_table_daemon | ||
from mycodo.utils.influx import add_measurements_influxdb | ||
from mycodo.utils.influx import read_influxdb_single | ||
from mycodo.utils.system_pi import return_measurement_info | ||
from mycodo.utils.utils import random_alphanumeric | ||
|
||
measurements_dict = { | ||
0: { | ||
'measurement': 'duty_cycle', | ||
'unit': 'percent' | ||
} | ||
} | ||
|
||
channels_dict = { | ||
0: { | ||
'types': ['pwm'], | ||
'measurements': [0] | ||
} | ||
} | ||
|
||
OUTPUT_INFORMATION = { | ||
'output_name_unique': 'MQTT_PAHO_PWM', | ||
'output_name': "{}: MQTT Publish".format(lazy_gettext('PWM')), | ||
'output_library': 'paho-mqtt', | ||
'output_manufacturer': 'Mycodo', | ||
'measurements_dict': measurements_dict, | ||
'channels_dict': channels_dict, | ||
'output_types': ['pwm'], | ||
|
||
'url_additional': 'http://www.eclipse.org/paho/', | ||
|
||
'message': 'Publish a PWM value to an MQTT server.', | ||
|
||
'dependencies_module': [ | ||
('pip-pypi', 'paho', 'paho-mqtt==1.5.1') | ||
], | ||
|
||
'custom_commands': [ | ||
{ | ||
'type': 'message', | ||
'default_value': """Set the Duty Cycle.""" | ||
}, | ||
{ | ||
'id': 'duty_cycle', | ||
'type': 'float', | ||
'default_value': 0, | ||
'name': 'Duty Cycle', | ||
'phrase': 'The duty cycle to set' | ||
}, | ||
{ | ||
'id': 'set_duty_cycle', | ||
'type': 'button', | ||
'wait_for_return': True, | ||
'name': 'Set Duty Cycle' | ||
} | ||
], | ||
|
||
'custom_channel_options': [ | ||
{ | ||
'id': 'hostname', | ||
'type': 'text', | ||
'default_value': 'localhost', | ||
'required': True, | ||
'name': lazy_gettext('Hostname'), | ||
'phrase': 'The hostname of the MQTT server' | ||
}, | ||
{ | ||
'id': 'port', | ||
'type': 'integer', | ||
'default_value': 1883, | ||
'required': True, | ||
'name': lazy_gettext('Port'), | ||
'phrase': 'The port of the MQTT server' | ||
}, | ||
{ | ||
'id': 'topic', | ||
'type': 'text', | ||
'default_value': 'paho/test/single', | ||
'required': True, | ||
'name': 'Topic', | ||
'phrase': 'The topic to publish with' | ||
}, | ||
{ | ||
'id': 'keepalive', | ||
'type': 'integer', | ||
'default_value': 60, | ||
'required': True, | ||
'constraints_pass': constraints_pass_positive_or_zero_value, | ||
'name': lazy_gettext('Keep Alive'), | ||
'phrase': 'The keepalive timeout value for the client. Set to 0 to disable.' | ||
}, | ||
{ | ||
'id': 'clientid', | ||
'type': 'text', | ||
'default_value': 'client_{}'.format(random_alphanumeric(8)), | ||
'required': True, | ||
'name': 'Client ID', | ||
'phrase': 'Unique client ID for connecting to the MQTT server' | ||
}, | ||
{ | ||
'id': 'login', | ||
'type': 'bool', | ||
'default_value': False, | ||
'name': 'Use Login', | ||
'phrase': 'Send login credentials' | ||
}, | ||
{ | ||
'id': 'username', | ||
'type': 'text', | ||
'default_value': 'user', | ||
'required': False, | ||
'name': lazy_gettext('Username'), | ||
'phrase': 'Username for connecting to the server' | ||
}, | ||
{ | ||
'id': 'password', | ||
'type': 'text', | ||
'default_value': '', | ||
'required': False, | ||
'name': lazy_gettext('Password'), | ||
'phrase': 'Password for connecting to the server.' | ||
}, | ||
{ | ||
'id': 'mqtt_use_websockets', | ||
'type': 'bool', | ||
'default_value': False, | ||
'required': False, | ||
'name': 'Use Websockets', | ||
'phrase': 'Use websockets to connect to the server.' | ||
}, | ||
{ | ||
'id': 'state_startup', | ||
'type': 'select', | ||
'default_value': '', | ||
'options_select': [ | ||
(-1, 'Do Nothing'), | ||
(0, 'Off'), | ||
('set_duty_cycle', 'User Set Value'), | ||
('last_duty_cycle', 'Last Known Value') | ||
], | ||
'name': lazy_gettext('Startup State'), | ||
'phrase': 'Set the state when Mycodo starts' | ||
}, | ||
{ | ||
'id': 'startup_value', | ||
'type': 'float', | ||
'default_value': 0.0, | ||
'required': True, | ||
'name': lazy_gettext('Startup Value'), | ||
'phrase': 'The value when Mycodo starts' | ||
}, | ||
{ | ||
'id': 'state_shutdown', | ||
'type': 'select', | ||
'default_value': '', | ||
'options_select': [ | ||
(-1, 'Do Nothing'), | ||
(0, 'Off'), | ||
('set_duty_cycle', 'User Set Value') | ||
], | ||
'name': lazy_gettext('Shutdown State'), | ||
'phrase': 'Set the state when Mycodo shuts down' | ||
}, | ||
{ | ||
'id': 'shutdown_value', | ||
'type': 'float', | ||
'default_value': 0.0, | ||
'required': True, | ||
'name': lazy_gettext('Shutdown Value'), | ||
'phrase': 'The value when Mycodo shuts down' | ||
}, | ||
{ | ||
'id': 'pwm_invert_signal', | ||
'type': 'bool', | ||
'default_value': False, | ||
'name': lazy_gettext('Invert Signal'), | ||
'phrase': 'Invert the PWM signal' | ||
}, | ||
{ | ||
'id': 'pwm_invert_stored_signal', | ||
'type': 'bool', | ||
'default_value': False, | ||
'name': lazy_gettext('Invert Stored Signal'), | ||
'phrase': 'Invert the value that is saved to the measurement database' | ||
}, | ||
{ | ||
'id': 'amps', | ||
'type': 'float', | ||
'default_value': 0.0, | ||
'required': True, | ||
'name': "{} ({})".format(lazy_gettext('Current'), lazy_gettext('Amps')), | ||
'phrase': 'The current draw of the device being controlled' | ||
} | ||
] | ||
} | ||
|
||
|
||
class OutputModule(AbstractOutput): | ||
"""An output support class that operates an output.""" | ||
def __init__(self, output, testing=False): | ||
super().__init__(output, testing=testing, name=__name__) | ||
|
||
self.publish = None | ||
|
||
output_channels = db_retrieve_table_daemon( | ||
OutputChannel).filter(OutputChannel.output_id == self.output.unique_id).all() | ||
self.options_channels = self.setup_custom_channel_options_json( | ||
OUTPUT_INFORMATION['custom_channel_options'], output_channels) | ||
|
||
def initialize(self): | ||
import paho.mqtt.publish as publish | ||
|
||
self.publish = publish | ||
|
||
self.setup_output_variables(OUTPUT_INFORMATION) | ||
self.output_setup = True | ||
|
||
try: | ||
if self.options_channels['state_startup'][0] == 0: | ||
self.output_switch('off') | ||
self.logger.info("PWM turned off (0 % duty cycle)") | ||
elif self.options_channels['state_startup'][0] == 'set_duty_cycle': | ||
self.output_switch('on', amount=self.options_channels['startup_value'][0]) | ||
self.logger.info("PWM set to {} % duty cycle (user-specified value)".format( | ||
self.options_channels['startup_value'][0])) | ||
elif self.options_channels['state_startup'][0] == 'last_duty_cycle': | ||
device_measurement = db_retrieve_table_daemon(DeviceMeasurements).filter( | ||
and_(DeviceMeasurements.device_id == self.unique_id, | ||
DeviceMeasurements.channel == 0)).first() | ||
|
||
last_measurement = None | ||
if device_measurement: | ||
channel, unit, measurement = return_measurement_info(device_measurement, None) | ||
last_measurement = read_influxdb_single( | ||
self.unique_id, | ||
unit, | ||
channel, | ||
measure=measurement, | ||
value='LAST') | ||
|
||
if last_measurement: | ||
self.logger.info( | ||
"PWM set to {} % duty cycle (last known value)".format( | ||
last_measurement[1])) | ||
self.output_switch('on', amount=last_measurement[1]) | ||
else: | ||
self.logger.error( | ||
"Output instructed at startup to be set to " | ||
"the last known duty cycle, but a last known " | ||
"duty cycle could not be found in the measurement " | ||
"database") | ||
except Exception as except_msg: | ||
self.logger.exception("Output was unable to be setup: {err}".format(err=except_msg)) | ||
|
||
def output_switch(self, state, output_type=None, amount=None, output_channel=0): | ||
measure_dict = copy.deepcopy(measurements_dict) | ||
|
||
try: | ||
auth_dict = None | ||
if self.options_channels['login'][0]: | ||
if not self.options_channels['password'][0]: | ||
self.options_channels['password'][0] = None | ||
auth_dict = { | ||
"username": self.options_channels['username'][0], | ||
"password": self.options_channels['password'][0] | ||
} | ||
|
||
if state == 'on': | ||
if self.options_channels['pwm_invert_signal'][0]: | ||
amount = 100.0 - abs(amount) | ||
elif state == 'off': | ||
if self.options_channels['pwm_invert_signal'][0]: | ||
amount = 100 | ||
else: | ||
amount = 0 | ||
|
||
self.publish.single( | ||
self.options_channels['topic'][0], | ||
amount, | ||
hostname=self.options_channels['hostname'][0], | ||
port=self.options_channels['port'][0], | ||
client_id=self.options_channels['clientid'][0], | ||
keepalive=self.options_channels['keepalive'][0], | ||
auth=auth_dict, | ||
transport='websockets' if self.options_channels['mqtt_use_websockets'][0] else 'tcp') | ||
|
||
self.logger.debug("Duty cycle set to {dc:.2f} %".format(dc=amount)) | ||
|
||
if self.options_channels['pwm_invert_stored_signal'][0]: | ||
amount = 100.0 - abs(amount) | ||
|
||
self.output_states[output_channel] = amount | ||
|
||
measure_dict[0]['value'] = amount | ||
add_measurements_influxdb(self.unique_id, measure_dict) | ||
|
||
return "success" | ||
except Exception as e: | ||
self.logger.error("State change error: {}".format(e)) | ||
return | ||
|
||
def is_on(self, output_channel=0): | ||
if self.is_setup(): | ||
if output_channel is not None and output_channel in self.output_states: | ||
return self.output_states[output_channel] | ||
else: | ||
return self.output_states | ||
|
||
def is_setup(self): | ||
return self.output_setup | ||
|
||
def stop_output(self): | ||
"""Called when Output is stopped.""" | ||
if self.is_setup(): | ||
if self.options_channels['state_shutdown'][0] == 0: | ||
self.output_switch('off') | ||
elif self.options_channels['state_shutdown'][0] == 'set_duty_cycle': | ||
self.output_switch('on', amount=self.options_channels['shutdown_value'][0]) | ||
self.running = False | ||
|
||
def set_duty_cycle(self, args_dict): | ||
if 'duty_cycle' not in args_dict: | ||
self.logger.error("Cannot set without duty cycle") | ||
return | ||
return_str = self.control.output_on( | ||
self.output.unique_id, | ||
output_type='pwm', | ||
amount=args_dict["duty_cycle"], | ||
output_channel=0) | ||
return f"Setting duty cycle: {return_str}" |