Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Add Standard Modbus/TCP protocol support #218

Merged
merged 7 commits into from
Jan 5, 2025
Merged
Show file tree
Hide file tree
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension


Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
39 changes: 25 additions & 14 deletions README.md
Original file line number Diff line number Diff line change
Expand Up @@ -21,15 +21,16 @@ When your inverter turns out to work well with an already exiting metrics group,

**The list below is built basing on the reports from the users. Compatiblity is not guaranteed.**

| Inverter model | Metric groups |
| -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
| [Deye SUN-4/5/6/7/8/10/12K-G05-P](https://deye.com/product/sun-4-5-6-7-8-10-12k-g05-4-12kw-three-phase-2-mppt/) | [string](docs/metric_group_string.md), [settings](docs/metric_group_settings.md) |
| [Deye Microinverters 300/500/600/800/1000/1300/2000]() | [micro](docs/metric_group_micro.md), [settings_micro](docs/metric_group_settings_micro.md) |
| [Deye Microinverters M60/M80/M100](https://deye.com/product/sun-m60-80-100g4-eu-q0/) | [micro](docs/metric_group_micro.md), [settings](docs/metric_group_settings.md) |
| [Deye Microinverters M130/M160/M180/M200/M220](https://deye.com/product/sun-m130-160-180-200-220g4-eu-q0/) | [micro](docs/metric_group_micro.md), [settings](docs/metric_group_settings.md) |
| [Deye SG04LP3](https://deye.com/product/sun-5-6-8-10-12k-sg04lp3-eu/) | [deye_sg04lp3](docs/metric_group_deye_sg04lp3.md), [deye_sg04lp3_battery](docs/metric_group_deye_sg04lp3_battery.md), [deye_sg04lp3_ups](docs/metric_group_deye_sg04lp3_ups.md), [deye_sg04lp3_timeofuse](docs/metric_group_deye_sg04lp3_timeofuse.md), [deye_sg04lp3_generator](docs/metric_group_deye_sg04lp3_generator.md), [settings](docs/metric_group_settings.md) |
| [Deye SG01LP1](https://deye.com/product/sun-7-6-8k-sg01lp1-eu/) | [deye_hybrid](docs/metric_group_deye_hybrid.md), [deye_hybrid_battery](docs/metric_group_deye_hybrid_battery.md), [deye_hybrid_bms](docs/metric_group_deye_hybrid_bms.md), [deye_hybrid_timeofuse](docs/metric_group_deye_hybrid_timeofuse.md), [settings](docs/metric_group_settings.md) |
| [Deye SG01HP3](https://deye.com/product/sun-5-6-8-10-12-15-20-25k-sg01hp3-eu-am2/) | [deye_sg01hp3](docs/metric_group_deye_sg01hp3.md), [deye_sg01hp3_battery](docs/metric_group_deye_sg01hp3_battery.md), [deye_sg01hp3_bms](docs/metric_group_deye_sg01hp3_bms.md), [deye_sg01hp3_ups](docs/metric_group_deye_sg01hp3_ups.md), [settings](docs/metric_group_settings.md) |
| Inverter model | Protocol | Metric groups |
| --------------------------------------------------------------------------------------------------------------- | -------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ |
| [Deye SUN-4/5/6/7/8/10/12K-G05-P](https://deye.com/product/sun-4-5-6-7-8-10-12k-g05-4-12kw-three-phase-2-mppt/) | tcp, at | [string](docs/metric_group_string.md), [settings](docs/metric_group_settings.md) |
| [Deye SUN-3/4/5/6/7/8/9/10/12/15K-G06P3](https://deye.com/product/sun-4-5-6-7-8-10-12k-g05-4-12kw-three-phase-2-mppt/) | mbtcp | [string](docs/metric_group_string.md), [settings](docs/metric_group_settings.md) |
| [Deye Microinverters 300/500/600/800/1000/1300/2000]() | tcp, at | [micro](docs/metric_group_micro.md), [settings_micro](docs/metric_group_settings_micro.md) |
| [Deye Microinverters M60/M80/M100](https://deye.com/product/sun-m60-80-100g4-eu-q0/) | tcp, at | [micro](docs/metric_group_micro.md), [settings](docs/metric_group_settings.md) |
| [Deye Microinverters M130/M160/M180/M200/M220](https://deye.com/product/sun-m130-160-180-200-220g4-eu-q0/) | tcp, at | [micro](docs/metric_group_micro.md), [settings](docs/metric_group_settings.md) |
| [Deye SG04LP3](https://deye.com/product/sun-5-6-8-10-12k-sg04lp3-eu/) | tcp, at | [deye_sg04lp3](docs/metric_group_deye_sg04lp3.md), [deye_sg04lp3_battery](docs/metric_group_deye_sg04lp3_battery.md), [deye_sg04lp3_ups](docs/metric_group_deye_sg04lp3_ups.md), [deye_sg04lp3_timeofuse](docs/metric_group_deye_sg04lp3_timeofuse.md), [deye_sg04lp3_generator](docs/metric_group_deye_sg04lp3_generator.md), [settings](docs/metric_group_settings.md) |
| [Deye SG01LP1](https://deye.com/product/sun-7-6-8k-sg01lp1-eu/) | tcp, at | [deye_hybrid](docs/metric_group_deye_hybrid.md), [deye_hybrid_battery](docs/metric_group_deye_hybrid_battery.md), [deye_hybrid_bms](docs/metric_group_deye_hybrid_bms.md), [deye_hybrid_timeofuse](docs/metric_group_deye_hybrid_timeofuse.md), [settings](docs/metric_group_settings.md) |
| [Deye SG01HP3](https://deye.com/product/sun-5-6-8-10-12-15-20-25k-sg01hp3-eu-am2/) | tcp, at | [deye_sg01hp3](docs/metric_group_deye_sg01hp3.md), [deye_sg01hp3_battery](docs/metric_group_deye_sg01hp3_battery.md), [deye_sg01hp3_bms](docs/metric_group_deye_sg01hp3_bms.md), [deye_sg01hp3_ups](docs/metric_group_deye_sg01hp3_ups.md), [settings](docs/metric_group_settings.md) |

| Meter model | Metric groups |
| ------------------------------------------------------------------- | ------------------------------------------------- |
Expand All @@ -43,9 +44,13 @@ Rebranded models


## :hammer_and_wrench: Installation
The communication with the logger can be performed using either Modbus/TCP or Modbus/AT protocol.
This project has been started with Modbus/TCP protocol support and it's still the default one.
However, logger firmware versions 2.x does not seem to expose Modbus/TCP interface anymore, hence Modbus/AT protocol support has been implemented. Use `DEYE_LOGGER_PROTOCOL` environment variable to select
The communication with the logger can be performed using one of three different protocols:
* Proprietary Deye Modbus/TCP protocol - used by inverters produced until 2024 (configuration code is `tcp`)
* Proprietary Deye Modbus/AT protocol - used by inverters produced until 2024 (configuration code is `at`)
* Standard Modbus/TCP protocol - used by some? inverters produced starting from 2024 onwards. (configuration code is `mbtcp`)

This project has been started with proprietary Deye Modbus/TCP protocol support and it's still the default one.
However, logger firmware versions 2.x does not seem to expose Modbus/TCP interface anymore, hence proprietary Deye Modbus/AT protocol support has been implemented. Use `DEYE_LOGGER_PROTOCOL` environment variable to select
the communication protocol.
Please note, that Modbus/TCP uses tcp/ip, while Modbus/AT uses udp/ip communication.

Expand Down Expand Up @@ -166,8 +171,14 @@ All configuration options are controlled through environment variables.
* `DEYE_LOGGER_COUNT` - declares the number of inverters, and therefore loggers to connect, optional, defaults to `0`, which means, that multi-inverter support is disabled
* `DEYE_LOGGER_SERIAL_NUMBER` or `DEYE_LOGGER_{N}_SERIAL_NUMBER` - inverter data logger serial number
* `DEYE_LOGGER_IP_ADDRESS` or `DEYE_LOGGER_{N}_IP_ADDRESS` - inverter data logger IP address
* `DEYE_LOGGER_PORT` or `DEYE_LOGGER_{N}_PORT` - inverter data logger communication port, optional, defaults to 8899 for Modbus/TCP, and 48899 for Modbus/AT
* `DEYE_LOGGER_PROTOCOL` or `DEYE_LOGGER_{N}_PROTOCOL` - inverter communication protocol, optional, either `tcp` for Modbus/TCP, or `at` for Modbus/AT, defaults to `tcp`
* `DEYE_LOGGER_PORT` or `DEYE_LOGGER_{N}_PORT` - inverter data logger communication port, optional, defaults to:
* 8899 for proprietary Deye Modbus/TCP
* 48899 for proprietary Deye Modbus/AT
* 502 for standard Deye Modbus/TCP
* `DEYE_LOGGER_PROTOCOL` or `DEYE_LOGGER_{N}_PROTOCOL` - inverter communication protocol, optional, defaults to `tcp`, can be set to one of:
* `tcp` for proprietary Deye Modbus/TCP
* `at` for proprietary Deye Modbus/AT
* `mbtcp` for standard Modbus/TCP
* `DEYE_LOGGER_MAX_REG_RANGE_LENGTH` or `DEYE_LOGGER_{N}_MAX_REG_RANGE_LENGTH`- controls maximum number of registers to be read in a single Modbus registers read operation, defaults to 256
* `DEYE_FEATURE_MQTT_PUBLISHER` - controls, if the service will publish metrics over mqtt, defaults to `true`
* `DEYE_FEATURE_SET_TIME` - when set to `true`, the service will automatically set the inverter/logger time, defaults to `false`
Expand Down