Document a special case of Calibration Type 10 #321

Merged
merged 1 commit into from
Oct 14, 2023
Merged
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
Original file line number Diff line number Diff line change
Expand Up @@ -68,7 +68,7 @@ This calibration is used on joints with incremental encoder that needs to reach
|`calibrationDelta`| defined by user expressed in degree|

!!!note
**The hardstop could be out of range of user limits, but it needs to be inside hardware limits; so the hardstop could be a hardware limit and the joint is calibrated after reaching it, but the controller verifies that the first received setpoint is inside user limits, else limits it to the nearest user limit.**
The hardstop could be out of range of user limits, but it needs to be inside hardware limits; so the hardstop could be a hardware limit and the joint is calibrated after reaching it, but the controller verifies that the first received setpoint is inside user limits, else limits it to the nearest user limit.

### Calibration 6
This calibration can be used for joint with `MAIS` and `FAP` board encoders. On iCub robots, distal and proximal joints use `MAIS`, while `FAP` are employed on ergoCub fingers.
Expand Down Expand Up @@ -136,7 +136,7 @@ If for some reason it insn't enough, the calibration fails.


### Calibration 10
This calibration is used for joints with relative encoders, which are calibrated by moving against the hard-stop limit. It is used for example in R1 lower arm pronosupination and in iCub 3 lower body when AMO sensors are used as relative encoders.
This calibration is used for joints with relative encoders, which are calibrated by moving against the hard-stop limit. It is used for example in R1 lower arm pronosupination and in iCub 3 when AMO sensors are used as relative encoders.

Regarding iCub 3 and the AMO boards, the AMO magnetic target is subdivided into 64 or 32 sectors. The AMO sensor provides a 14-bit resolution per sector, for a total of 14+6=20 or 14+5=19 bits per revolution resolution, respectively. The `Gearbox_E2J` parameter must be configured with the number of sectors in the corresponding `mechanicals/part-mec.xml` file.

Expand All @@ -151,6 +151,9 @@ Regarding iCub 3 and the AMO boards, the AMO magnetic target is subdivided into
|`calibrationZero`| position (in degrees) at the hard-stop limit|
|`calibrationDelta`| defined by user expressed in degree|

!!!note
On AMO-based robots (e.g., iCub 3, ergoCub), the AMO sensors can be completely disabled to favor the use of the quadrature encoders only by changing the value of the `amo` parameter to `none` within the `hardware/motorControl/*service.html` files.

### Calibration 12
This calibration is used for joint with absolute encoder, it is the newest version of calibration 3 and it simplifies the calibration procedure for the user; in fact the user needs only to write in calibration1 parameter the raw value read when jont is in 0.0 position and the firmware calculates the correct offset.

Expand Down Expand Up @@ -191,7 +194,7 @@ After that, by observing how the values printed out by the port change, you woul
|`calibrationDelta`| defined by user expressed in degree |

!!!note
**The `calibration14` rotation parameter cannot assume any value. Allowed values are: `0`, `32768`, `16384`, `-16384`, expressed in `iCubDegrees` as specified in the table above. Specifically, these values correspond to the following numbers in degrees: `0`, `180`, `90`, `-90`. Notice how these values are only accepted without decimals; therefore, only integer parts are checked. In fact, multiplying the degrees by the conversion factor, defined in the [Legend](#legend) section, generates outputs with decimals. Thus, it has been decided to round them up.**
The `calibration14` rotation parameter cannot assume any value. Allowed values are: `0`, `32768`, `16384`, `-16384`, expressed in `iCubDegrees` as specified in the table above. Specifically, these values correspond to the following numbers in degrees: `0`, `180`, `90`, `-90`. Notice how these values are only accepted without decimals; therefore, only integer parts are checked. In fact, multiplying the degrees by the conversion factor, defined in the [Legend](#legend) section, generates outputs with decimals. Thus, it has been decided to round them up.

!!!info
Considering that this calibration works in close relation with absolute encoders, it is necessary to keep in mind the following note.
Expand All @@ -205,7 +208,7 @@ After that, by observing how the values printed out by the port change, you woul
- `iCubDegree`: the firmware uses iCubDegree instead of degree in order to use more resolution.

!!!info
1 Degree = 182.044 iCubDegree, where 182.044 is 65535/360; The value 182.044 is contained in the parameter “Encoder” of mechanicals configuration files of each robot.
1 Degree = 182.044 iCubDegree, where 182.044 is 65535/360; The value 182.044 is contained in the parameter “Encoder” of mechanical configuration files of each robot.

- `Encoder conversion` factor: is the factor used by firmware to convert the value read from encoder to iCubDegree.