166 changes: 166 additions & 0 deletions docs/install-upgrade/build-wiring.md
Original file line number Diff line number Diff line change
Expand Up @@ -85,6 +85,27 @@ This section is meant to help the reader understand how to assemble the primitiv
A VPC allows for isolation at layer 3. This is the main building block for users when creating their architecture. Hosts inside of a VPC belong to the same broadcast domain and can communicate with each other, if desired a single VPC can be configured with multiple broadcast domains. The hosts inside of a VPC will likely need to connect to other VPCs or the outside world. To communicate between two VPC a *peering* will need to be created. A VPC can be a logical separation of workloads. By separating these workloads additional controls are available. The logical separation doesn't have to be the traditional database, web, and compute layers it could be development teams who need isolation, it could be tenants inside of an office building, or any separation that allows for better control of the network. Once your VPCs are decided, the rest of the fabric will come together. With the VPCs decided traffic can be prioritized, security can be put into place, and the wiring can begin. The fabric allows for the VPC to span more than a than one switch, which provides great flexibility, for instance workload mobility.
``` mermaid
graph TD
L1([Leaf 1])
L2([Leaf 2])
S1["Server 1
10.1.0.1"]
S2["Server 2
10.1.0.2"]
S3["Server 3
10.1.0.3"]

L1 <--> S1
L1 <--> S2
L2 <--> S3

subgraph VPC 1
S1
S2
S3
end
```
### Connection

A connection represents the physical wires in your data center. They connect switches to other switches or switches to servers.
Expand All @@ -98,6 +119,56 @@ A server connection is a connection used to connect servers to the fabric. The f
- *MCLAG* - Two cables going to two different switches, also called dual homing. The switches will need a fabric link between them.
- *ESLAG* - Two to four cables going to different switches, also called multi-homing. If four links are used there will need to be four switches connected to a single server with four NIC ports.

``` mermaid
graph TD
S1([Spine 1])
S2([Spine 2])
L1([Leaf 1])
L2([Leaf 2])
L3([Leaf 3])
L4([Leaf 4])
L5([Leaf 5])
L6([Leaf 6])
L7([Leaf 7])
TS1[Server1]
TS2[Server2]
TS3[Server3]
TS4[Server4]
S1 ---- L1 & L2 & L3 & L4 & L5 & L6 & L7
S2 ---- L1 & L2 & L3 & L4 & L5 & L6 & L7
L1 <-- Bundled --> TS1
L1 <-- Bundled --> TS1
L1 <-- Unbundled --> TS2
L2 <-- MCLAG --> TS3
L3 <-- MCLAG --> TS3
L4 <-- ESLAG --> TS4
L5 <-- ESLAG --> TS4
L6 <-- ESLAG --> TS4
L7 <-- ESLAG --> TS4
subgraph VPC 1
TS1
TS2
TS3
TS4
end
subgraph MCLAG
L2
L3
end
subgraph ESLAG
L3
L4
L5
L6
L7
end
```
#### Fabric Connections

Fabric connections serve as connections between switches, they form the fabric of the network.
Expand All @@ -107,14 +178,109 @@ Fabric connections serve as connections between switches, they form the fabric o

VPCs need VPC Peerings to talk to each other. VPC Peerings come in two varieties: local and remote.

``` mermaid
graph TD
S1([Spine 1])
S2([Spine 2])
L1([Leaf 1])
L2([Leaf 2])
TS1[Server1]
TS2[Server2]
TS3[Server3]
TS4[Server4]
S1 <--> L1
S1 <--> L2
S2 <--> L1
S2 <--> L2
L1 <--> TS1
L1 <--> TS2
L2 <--> TS3
L2 <--> TS4
subgraph VPC 1
TS1
TS2
end
subgraph VPC 2
TS3
TS4
end
```

#### Local VPC Peering

When there is no dedicated border/peering switch available in the fabric we can use local VPC peering. This kind of peering tries sends traffic between the two VPC's on the switch where either of the VPC's has workloads attached. Due to limitation in the Sonic network operating system this kind of peering bandwidth is limited to the number of VPC loopbacks you have selected while initializing the fabric. Traffic between the VPCs will use the loopback interface, the bandwidth of this connection will be equal to the bandwidth of port used in the loopback.

``` mermaid
graph TD
L1([Leaf 1])
S1[Server1]
S2[Server2]
S3[Server3]
S4[Server4]
L1 <-. loopback .-> L1;
L1 <-.-> S1;
L1 <--> S2;
L1 <-.-> S3;
L1 <--> S4;
linkStyle 1,2,4 color:blue;
subgraph VPC 1
S1
S2
end
subgraph VPC 2
S3
S4
end
```


#### Remote VPC Peering

Remote Peering is used when you need a high bandwidth connection between the VPCs, you will dedicate a switch to the peering traffic. This is either done on the border leaf or on a switch where either of the VPC's are not present. This kind of peering allows peer traffic between different VPC's at line rate and is only limited by fabric bandwidth. Remote peering introduces a few additional hops in the traffic and may cause a small increase in latency.

``` mermaid
graph TD
S1([Spine 1])
S2([Spine 2])
L1([Leaf 1])
L2([Leaf 2])
L3([Leaf 3])
TS1[Server1]
TS2[Server2]
TS3[Server3]
TS4[Server4]
S1 <-.5.-> L1;
S1 <-.2.-> L2;
S1 <-.3,4.-> L3;
S2 <--> L1;
S2 <--> L2;
S2 <--> L3;
L1 <-.6.-> TS1;
L1 <--> TS2;
L2 <--> TS3;
L2 <-.1.-> TS4;
subgraph VPC 1
TS1
TS2
end
subgraph VPC 2
TS3
TS4
end
```
The dotted line in the diagram shows the traffic flow for remote peering. The traffic could take a different path because of ECMP. It is important to note that Leaf 3 cannot have any servers from VPC 1 or VPC 2 on it, but it can have a different VPC attached to it.

#### VPC Loopback