New features:
- SA: Add an option in the configuration file to start from an initial state binary file (dumpstate)
- NSA: Allow having a different configuration in the same JSON file for N and SA
- NSA: automatically read the N final state file in SA for initialization (instead of IIDM)
Outputs:
- Properly initialize frozen0 parameter of VRemote and SVC
- Use the same precision in dynawo and in the simplified solver to avoid unstabilities in the curves
- Default stop time of N and SA in presence of a SVC is automatically increased to be sure the simulation is stabilized before the event
- timeline is now exported in XML format (for coherency with others result files)
Bug fixes:
- Fixed wrong MPI path used in distribution (which was causing crashes at runtime when MPI was installed on the system)
- Fix crash when filtering automaton that needs to be removed as not fully functional with the current configuration
- Make sure QNomAlt and SNon parameters are coherent in the SVC model and the generators in the SVC area
- Dump an error if a simulation contains SVC areas and is using a flat start
- Shunts initially disconnected in NODE_BREAKER topology are taken into account in automaton connections (allowing the automatons to connect them during the simulation)