Thin integration is a side project which works only with 1 zone climate configured. It logs in to Ariston website (https://www.ariston-net.remotethermo.com) and fetches/sets data on that site.
You are free to modify and distribute it. It is distributed 'as is' with no liability for possible damage.
Cimate has presets to switch between off
, summer
and winter
in order to be able to control boiler from one entity.
If you like this app, please consider donating some sum to your local charity organizations or global organization like Red Cross. I don't mind receiving donations myself (you may conact me for more details if you want to), but please consider charity at first.
Intergation uses api developed by me based on assumptions and test results. It continiously fetches the data from the site with periods determined during tests to have not as many interference with other applications (like Ariston NET application or Google Home application) but be quick enough to get information as soon as possible.
You may read more about API (ariston.py
) on the website: https://pypi.org/project/aristonremotethermo/.
- Ariston Clas Evo
- Ariston Genus One with Ariston BCH cylinder
- Ariston Nimbus Flex
- Ariston Alteas One (note that
internet_weather
is not supported by this model and must not be included in switches or binary sensors)
- Ariston Lydos. use https://github.com/chomupashchuk/ariston-aqua-remotethermo-home-assistant instead.
- Ariston Velis. use https://github.com/chomupashchuk/ariston-aqua-remotethermo-home-assistant instead.
- Ariston Lydos Hybrid. use https://github.com/chomupashchuk/ariston-aqua-remotethermo-home-assistant instead.
You may check possible support of your boiler by logging into https://www.ariston-net.remotethermo.com and if climate and water heater parts (like temperatures) are available on the home page, then intergation should potentially work.
In /config
folder create custom_components
folder and folder ariston
with its contents in it.
In configuration.yaml
include:
ariston:
username: !secret ariston_username
password: !secret ariston_password
All optional attributes are described in Integration attributes
Order of Installation:
- Copy data to
custom_components
; - Restart Home Assistant to find the component;
- Include data in
configuration.yaml
; - Restart Home Asistant to see new services.
username
- mandatory user name used in https://www.ariston-net.remotethermo.compassword
- mandatory password used in https://www.ariston-net.remotethermo.com ! It is recommended for security purposes to not use your common password, just in case !name
- friendly name for integration, default isAriston
hvac_off_present
- indicates ifHVAC OFF
shall be present in climate entity. Default value isfalse
.hvac_off
- indicates how to treatHVAC OFF
action in climate (use depends onhvac_off_present
). Options areoff
andsummer
. By default it issummer
, which means that turning off would keep DHW water heating on (e.g. summer mode). Presets in climate allow switching betweenoff
,summer
andwinter
.store_config_files
-true
orfalse
indicating if configurationjson
files to be stored in/config/custom_components/ariston
folder. Can be used for troubleshooting purposes. Default value isfalse
.units
- which uniots to be used. Values are:metric
(°C-bar-kW...),imperial
(°F-psi-kBtu/h...),auto
(detect automatically, which takes additional time). Default ismetric
. Note that use ofauto
requires additional request to be used, which would result in slower update of other sensors.polling
- sets floating value of relative polling rate. Default is 1.0. Setting value to 2.0 for example would increase timeouts times and retries by 2 times. It is recommended to set this value to more than one (e.g. 1.2) in case timeouts take place very frequently.logging
- sets logging level (CRITICAL
,ERROR
,WARNING
,INFO
,DEBUG
,NOTSET
). Default isDEBUG
.
Some parameters are not supported on all models
internet_time
- turn off and on sync with internet time.internet_weather
- turn off and on fetching of weather from internet. WORKS ONLY ON SPECIFIC MODELS WHILE ON OTHERS CAUSES CRASHESch_auto_function
- turn off and on Auto function.dhw_thermal_cleanse_function
- DHW thermal cleanse function enabled.
Some parameters are not supported on all models
account_ch_gas
- gas use summary for CH. Not supported on all models.account_ch_electricity
- electricity use summary for CH. Not supported on all models.account_dhw_gas
- gas use summary for DHW. Not supported on all models.account_dhw_electricity
- electricity use summary for DHW. Not supported on all models.ch_antifreeze_temperature
- CH antifreeze temperature.ch_detected_temperature
- temperature measured by thermostat.ch_mode
- mode of CH (manual
orscheduled
and others).ch_comfort_temperature
- CH comfort temperature.ch_economy_temperature
- CH economy temperature.ch_set_temperature
- set CH temperature.ch_program
- CH Time Program.ch_water_temperature
- CH Water Temperature. WORKS ONLY ON SPECIFIC MODELS WHILE ON OTHERS CAUSES CRASHEScooling_last_24h
- energy use for pump cooling in a day.cooling_last_7d
- energy use for pump cooling in a week.cooling_last_30d
- energy use for pump cooling in a month.cooling_last_365d
- energy use for pump cooling in a year.dhw_program
- DHW Time Program.dhw_comfort_function
- DHW comfort function.dhw_mode
- mode of DHW. Not supported on all models.dhw_comfort_temperature
- DHW storage comfort temperature. Not supported on all models.dhw_economy_temperature
- DHW storage economy temperature. Not supported on all models.dhw_set_temperature
- set DHW temperature.dhw_storage_temperature
- DHW storage temperature. Not supported on all models.dhw_thermal_cleanse_cycle
- DHW thermal cleanse cycle.electricity_cost
- Electricity cost.errors_count
- active errors (no actual errors to test on).gas_type
- Gas type.gas_cost
- Gas cost.heating_last_24h
- energy use for heating in last 24 hours. Not supported on all models.heating_last_30d
- energy use for heating in last 7 days. Not supported on all models.heating_last_365d
- energy use for heating in last 30 days. Not supported on all models.heating_last_7d
- energy use for heating in last 365 days. Not supported on all models.mode
- mode of boiler (off
orsummer
orwinter
and others).outside_temperature
- outside temperature. Not supported on all models.signal_strength
- Wifi signal strength.units
- Units of measurementwater_last_24h
- energy use for water in last 24 hours. Not supported on all models.water_last_30d
- energy use for water in last 7 days. Not supported on all models.water_last_365d
- energy use for water in last 30 days. Not supported on all models.water_last_7d
- energy use for water in last 365 days. Not supported on all models.
Some parameters are not supported on all models
ch_auto_function
- CH AUTO function status.ch_flame
- CH heating ongoing.ch_pilot
- CH Pilot mode.dhw_flame
- DHW heating ongoing. This parameter is not reported by boilers and is approximated based on multiple parameters.dhw_thermal_cleanse_function
- DHW thermal cleanse function.flame
- CH and/or DHW heating ongoing.heat_pump
- Heating pump status.holiday_mode
- Holiday mode status.internet_time
- Internet time status.internet_weather
- Internet weather status. WORKS ONLY ON SPECIFIC MODELS WHILE ON OTHERS CAUSES CRASHESchanging_data
- API is attempting to configure requested data. API specific sensor.online
- Online status. Indicates if API has communication with the heater. API specific sensor.update
- API update status. API specific sensor.
ariston:
username: !secret ariston_user
password: !secret ariston_password
switches:
- internet_time
- internet_weather
sensors:
- ch_detected_temperature
- ch_mode
- ch_comfort_temperature
- ch_economy_temperature
- ch_set_temperature
- dhw_set_temperature
- errors_count
- mode
- outside_temperature
binary_sensors:
- changing_data
- online
ariston.set_data
- Sets the requested data.
entity_id
- mandatory entity of Aristonclimate
.- for the rest of attributes please see
Developer Tools
tabServices
within Home Assistant and selectariston.set_data
. You may also directly readservices.yaml
within theariston
folder.
service: ariston.set_data
data:
entity_id: 'climate.ariston'
ch_comfort_temperature: 20.5
Since integration interacts with server, which interacts with boiler directly or via gateway, it is possible that some link in the chain is not working. Integration is designed to constantly retry the connection (requests are sent more reearely in case of multiple faults to reduce load on whole chain). Mostly connection recovers in time, but sometimes restart of router or boiler can help (but not always).
Even though many functions are not accessible via integration once boiler configuration (parameter 228 in the menu) changed from 1 (boiler with water heater sensor) to 0 (default configuration without sensor), possibly due to packets corruption on the way or some specific bit sequence. It caused Genus One model not being able to handle DHW. The solution is to enter boiler menu directly and change the value of parameter 228. Also boiler might require restart (complete loss of power).
For example CH temperature set to 0, which is not in supported range. Try to log in into https://www.ariston-net.remotethermo.com and change the value there. If it does not help try disconnecting heater from electricity and connecting again.