Skip to content

chriszuercher/iec62056-lora

 
 

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

29 Commits
 
 
 
 
 
 
 
 
 
 

Repository files navigation

iec62056-lora

  • Periodically read current power, energy consumption and other OBIS-values from a electricity meter that support the IEC 62056-21 protocol.
  • Use LoRa/TTN to send the data to a (public or private) gateway
  • The gateway POST's the data to a Home-Assistant WebHook where the data is applied to several template sensors

State

  • Project is still work in progress (feel free to contribute)

  • In the beginning I was experimenting around with the Heltec lora esp32 micro-controller. That micro-controller is fully Arduino / Platformio compatible and work fine as long as you don't wanna power it by a battery as it consumed a lot of energy even in deep-sleep. Thus I switched to the Heltec CubeCell AB02 series that is specialized for battery operated use-cases.

  • I ran a long dozen of times up and down the staircase (third floor) down to the basement for this project - if you want to avoid that, free to buy me a coffee

    "Buy Me A Coffee"

My Hardware

Micro Controllers

Others

Installation

Heltec Cubecell AB02 (recommended)

Wiring

Pinout Diagramms:

Connect as following:

  • Optical Reading Head: VCC -> VEXT
  • Optical Reading Head: GND -> GND
  • Optical Reading Head: RX -> RX2 (GPIO 29)
  • Optical Reading Head: TX -> TX2 (GPIO 39)

Configuration

  • Rename credentials_example.h to credentials.h and provide your OTAA data
    • I generated random hex values for devEui, appEu and appKey
  • Select the correct board in the Arduino IDE:
    • Tools -> Boards -> CubeCell (in sketchbook) -> HTCC - AB02A
  • Set the LORAWAN values from within in the Arduino IDE:
    • Tools -> LORAWAN_REGION -> your-region (eg. EU_868)
    • Tools -> LORAWAN_CLASS -> A
    • Tools -> LORAWAN_DEVEUI -> CUSTOM
    • Tools -> LORAWAN_NETMODE -> OTAA
    • Tools -> AT_SUPPORT -> ON
  • Check/Adjust the ADJUSTME comments

Debugging / Hints

  • use the serial monitor in Arduino and change the DEFAULT_LOG_LEVEL to debug in the ino file

    • Attention: Make sure once everything works as intended to change it back to Info as too much logging has a negative impact on the power consumption (even if there is not serial monitor connected)
  • The smart meter is not interacted with as long as the LoRaWAN has not been initialized / OTAA-registered

    • uncomment the line deviceState = DEVICE_STATE_SEND in the wakeup procedure to directly read the smart meter data when the on-board user button is pressed without checking/waiting for a successfully LoRaWAN registration
  • Send a LoRaWan downlink message from your gateway to change the sleep time on demand. The message is read the next time the node wakes up.

    Port: 4
    payload: <desired-sleep-time-seconds-in-hex>  // 04B0 = 1200 seconds  = 20 min
    
  • Make sure you have a decent LoRaWAN connectivity where your smart-meter is located or nearby by using an extension cord/antenna. I played around with a simple LoRaWAN example sketch from Heltec to find a good spot with a decent connectivity:

    Examples -> CubeCell -> LoRa -> LoRaWAN -> LoRaWAN

    And then verified in my Lora-Gateway if the messages were received and if so, what their RSSI/SNR data were.

Heltec Wifi LoRA 32 V2 (deprecated)

  • Based on Platformio
  • Not suitable for my use-case as it consumed to much power (even in deep-sleep) and thus couldn't get it to operate by battery

Supported Smart Meters

  • Elster AS3000

    SKIP_CHECKSUM_CHECK
    METER_IDENTIFIER "ELS"
    BAUDRATE_CHANGE_DELAY: 500
    PARITY_SETTING SERIAL_7E1 
    OBIS_VALUE_POWER "1.7.0 "
    OBIS_VALUE_TOTAL_ENERGY "1.8.0"
    INITIAL_BAUD_RATE 300
    SERIAL_IDENTIFICATION_READING_TIMEOUT 2000
    SERIAL_READING_TIMEOUT  500
    MAX_METER_READ_TIME  60
    
  • Landys&Gyr ZMD120AR21

    SKIP_CHECKSUM_CHECK
    METER_IDENTIFIER "LGZ"
    BAUDRATE_CHANGE_DELAY: 500
    PARITY_SETTING SERIAL_7E1 
    OBIS_VALUE_POWER "1.7.0 "
    OBIS_VALUE_TOTAL_ENERGY "1.8.0"
    OBIS_VALUE_TOTAL_ENERGY_TARIFF1 "1.8.1"
    OBIS_VALUE_TOTAL_ENERGY_TARIFF2 "1.8.2"
    INITIAL_BAUD_RATE 300
    SERIAL_IDENTIFICATION_READING_TIMEOUT 2000
    SERIAL_READING_TIMEOUT  500
    MAX_METER_READ_TIME  60
    

Acknowledgements

TheThingsNetwork Integration

For TTN we can define a uplink payload formater to convert the data to a be used later in Home-Assistant via MQTT

function decodeUplink(input) {
  return {
    data: {
      bytes: input.bytes,
      power: (input.bytes[0] << 8) + (input.bytes[1]),
      energy: (input.bytes[2] << 24) + (input.bytes[3] << 16) + (input.bytes[4] << 8) + (input.bytes[5]),
      energy1: (input.bytes[6] << 24) + (input.bytes[7] << 16) + (input.bytes[8] << 8) + input.bytes[9],
      energy2: (input.bytes[10] << 24) + (input.bytes[11] << 16) + (input.bytes[12] << 8) + input.bytes[13],
      batteryPCT: input.bytes[14],
      battery:(input.bytes[15] << 8) + input.bytes[16],
      counter: input.bytes[17]
    },
    warnings: [],
    errors: []
  };
}

The coresponding MQQT Sensor in HomeAssistant can be configured like this. Replace APPLICAITON and DEVICE_EUI with the name of you TTN aplication and ID of your device. You can find the required data in the TTN console.

mqtt:
  sensor:
    - state_topic: "v3/APPLICATION@ttn/devices/DEVICE_EUI/up"
      name: "Smart Meter Kwh"
      unique_id: smart_meter_kwh
      icon: mdi:chart-histogram
      unit_of_measurement: "kWh"
      state_class: total_increasing
      device_class: energy
      value_template: >-
        {% set value = value_json.uplink_message.decoded_payload.energy | default(none) %}
        {% if value == '00000000' %}
          {{ none }}
        {% else %}
          {{ value | int(value,16)/100|float }}
        {% endif %}
    - state_topic: "v3/APPLICATION@ttn/devices/DEVICE_EUI/up"
      name: "Smart Meter Kwh Peak"
      unique_id: smart_meter_kwh_peak
      icon: mdi:chart-histogram
      unit_of_measurement: "kWh"
      state_class: total_increasing
      device_class: energy
      value_template: >-
        {% set value = value_json.uplink_message.decoded_payload.energy1 | default(none) %}
        {% if value == '00000000' %}
          {{ none }}
        {% else %}
          {{ value | int(value,16)/100|float }}
        {% endif %}
    - state_topic: "v3/APPLICATION@ttn/devices/DEVICE_EUI/up"
      name: "Smart Meter Kwh OffPeak"
      unique_id: smart_meter_kwh_offPeak
      icon: mdi:chart-histogram
      unit_of_measurement: "kWh"
      state_class: total_increasing
      device_class: energy
      value_template: >-
        {% set value = value_json.uplink_message.decoded_payload.energy2 | default(none) %}
        {% if value == '00000000' %}
          {{ none }}
        {% else %}
          {{ value | int(value,16)/100|float }}
        {% endif %}
    - state_topic: "v3/APPLICATION@ttn/devices/DEVICE_EUI/up"
      name: "Smart Meter Power"
      unique_id: smart_meter_power
      icon: mdi:flash-outline
      unit_of_measurement: "W"
      state_class: measurement
      device_class: power
      value_template: >-
        {% set value = value_json.uplink_message.decoded_payload.power | default(none) %}
        {% if value == '0000' %}
          {{ none }}
        {% else %}
          {{ value | int(value,16) }}
        {% endif %}
    - state_topic: "v3/APPLICATION@ttn/devices/DEVICE_EUI/up"
      name: "Smart Meter Battery"
      unique_id: smart_meter_battery
      icon: mdi:battery
      unit_of_measurement: "%"
      device_class: battery
      value_template: >-
        {% set value = value_json.uplink_message.decoded_payload.batteryPCT | default(none) %}
        {% if value == '00' %}
          {{ none }}
        {% else %}
          {{ value | int(value,16) }}
        {% endif %}
    - state_topic: "v3/APPLICATION@ttn/devices/DEVICE_EUI/up"
      name: "Smart Meter Battery Voltage"
      unique_id: smart_meter_battery_voltage
      icon: mdi:battery
      unit_of_measurement: "mV"
      state_class: measurement
      device_class: battery
      value_template: >-
        {% set value = value_json.uplink_message.decoded_payload.battery | default(none) %}
        {% if value == '0000' %}
          {{ none }}
        {% else %}
          {{ value | int(value,16) }}
        {% endif %}
    - state_topic: "v3/APPLICATION@ttn/devices/DEVICE_EUI/up"
      name: "Smart Meter Up-Counter"
      unique_id: smart_meter_upcounter
      icon: mdi:counter
      unit_of_measurement: "times"
      value_template: >-
        {% set value = value_json.uplink_message.decoded_payload.counter | default(none) %}
        {% if value == '00' %}
          {{ none }}
        {% else %}
          {{ value | int(value,16) }}
        {% endif %}

Home-Assistant Template Sensors

- trigger:
    - platform: webhook
      webhook_id: lorawan-data
      id: lorawan-data
  unique_id: smart_meter
  sensor:
    - name: "Smart Meter Power"
      unique_id: smart_meter_power
      icon: mdi:flash-outline
      unit_of_measurement: W
      device_class: power
      state_class: measurement
      state: >-
        {% set payloadHex = trigger.json.data.payload_hex | default(none) %}
        {% set value = payloadHex[0:4] %}
        {% if value == '0000' %}
          {{ none }}
        {% else %}
          {{ value | int(value,16) }}
        {% endif %}

    - name: "Smart Meter Kwh"
      unique_id: smart_meter_kwh
      icon: mdi:chart-histogram
      unit_of_measurement: "kWh"
      state_class: measurement
      device_class: energy
      state: >-
        {% set payloadHex = trigger.json.data.payload_hex | default(none) %}
        {% set value = payloadHex[4:12] %}
        {% if value == '00000000' %}
          {{ none }}
        {% else %}
          {{ value | int(value,16)/100|float }}
        {% endif %}

    - name: "Smart Meter Battery"
      unique_id: smart_meter_battery
      icon: mdi:battery
      unit_of_measurement: "%"
      device_class: battery
      state: >-
        {% set payloadHex = trigger.json.data.payload_hex | default(none) %}
        {% set value = payloadHex[12:14] %}
        {% if value == '00' %}
          {{ none }}
        {% else %}
          {{ value | int(value,16) }}
        {% endif %}

    - name: "Smart Meter Battery Voltage"
      unique_id: smart_meter_battery_voltage
      icon: mdi:battery
      unit_of_measurement: "mV"
      state_class: measurement
      device_class: voltage
      state: >-
        {% set payloadHex = trigger.json.data.payload_hex | default(none) %}
        {% set value = payloadHex[14:18] %}
        {% if value == '0000' %}
          {{ none }}
        {% else %}
          {{ value | int(value,16) }}
        {% endif %}

    - name: "Smart Meter Up-Counter"
      unique_id: smart_meter_upcounter
      icon: mdi:counter
      unit_of_measurement: "times"
      state: >-
        {% set payloadHex = trigger.json.data.payload_hex | default(none) %}
        {% set value = payloadHex[18:20] %}
        {% if value == '00' %}
          {{ none }}
        {% else %}
          {{ value | int(value,16) }}
        {% endif %}

About

No description, website, or topics provided.

Resources

Stars

Watchers

Forks

Releases

No releases published

Packages

No packages published

Languages

  • C++ 89.8%
  • C 10.2%