-
Notifications
You must be signed in to change notification settings - Fork 230
- No it doesn't: ConsoleZ is only a Windows console wrapper. It reads from the console screen buffer, and writes inputs into console input buffer (see MSDN documentation).
- Yes it does: You can use ansicon to translate ANSI escape codes. Even with this tool, ANSI escaping is still restricted to Windows console capabilities. So, you are limited to 16 colors. Personally, it doesn't bother me. I never needed more than 8 different text colors to display readable text!
Press the alt key.
Press F1 or use the menu to open the manual. If blank page with no content is displayed, then you have to disable the security restriction. See here or here.
Open the manual (press F1 in ConsoleZ) and follow instructions fromUsing ConsoleZ/Language settings
section.
First: verify your settings.
Second: Open the manual (press F1 in ConsoleZ) and follow instructions fromUsing ConsoleZ/Language settings
section. Windows calculates the max number of row/column using the primary monitor size and the Windows console font size (do not confuse with ConsoleZ font!). Set this smaller to get more rows and/or columns. Do not choose a raster font if you need unicode support.
- This animation requires a global hotkey to hide/show the application. Assign a hotkey to the command Activate ConsoleZ (global) in Settings/HotKeys.
- Window must be docked to a screen edge to determine animation direction. Select a Docking value, other than none, in Settings/Appearance.
- If AERO is active, non-client area is not supported. Consider to uncheck Caption and Resizable.
You configure a background color in settings (tabs/background
), and you see another color. The color you configured will replace the background color number 0. See in your shell documentation how to change the color number.
Usually, that means you configured a shell that cannot start. When you configure a shell, verify it starts before exiting the application. Never modify the first (default) tab settings. Test and if verification is OK, move your tab settings in first place.
By default, your configuration file is located in %APPDATA%\console
directory. Otherwise, it is located in the same directory as ConsoleZ program.
Rename it to reset configuration.
ConsoleZ language loading follows Windows standard order: first the user language, second the system language and last the neutral language (english). Resource dlls, named (console_<(ISO 639-2/B>.dll), are optional. They can be renamed or deleted.
Verify the executable has been built with large address support enabled. (See https://github.com/cbucher/console/issues/354)
You use 32bits version of ConsoleZ and attempt to load 64bits shell. Install 64bits version of ConsoleZ on 64bits OSes!