Notifications
You must be signed in to change notification settings - Fork 845
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
drivers: hwmon: max31827: add max31875
MAX31875 Low-Power I2C Temperature Sensor Signed-off-by: John Erasmus Mari Geronimo <[email protected]>
- Loading branch information
1 parent
d64a908
commit 7165f8f
Showing
2 changed files
with
303 additions
and
51 deletions.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
|
@@ -29,9 +29,18 @@ Supported chips: | |
|
||
Datasheet: Publicly available at the Analog Devices website | ||
|
||
* Maxim MAX31875 | ||
|
||
Prefix: 'max31875' | ||
|
||
Addresses scanned: I2C 0x48 - 0x4f | ||
|
||
Datasheet: Publicly available at the Analog Devices website | ||
|
||
|
||
Authors: | ||
- Daniel Matyas <[email protected]> | ||
- John Erasmus Mari Geronimo <[email protected]> | ||
|
||
Description | ||
----------- | ||
|
@@ -45,13 +54,20 @@ configured to operate in the same manner with 1 write operation to the | |
configuration register. From here on, we will refer to all these chips as | ||
MAX31827. | ||
|
||
MAX31827 implements a temperature sensor with a 6 WLP packaging scheme. This | ||
sensor measures the temperature of the chip itself. | ||
This driver also supports the MAX31875. Its fault queue is set to 1 and it has | ||
no alarm polarity. | ||
|
||
MAX31827 implements a temperature sensor with a 6 WLP packaging scheme while | ||
MAX31875 has a 4 WLP packaging scheme. This sensor measures the temperature of | ||
the chip itself. | ||
|
||
MAX31827 has low and over temperature alarms with an effective value and a | ||
hysteresis value: -40 and -30 degrees for under temperature alarm and +100 and | ||
+90 degrees for over temperature alarm. | ||
|
||
MAX31875 has only an over temperature alarm with an effective value and a | ||
hysteresis value: +80 and +75 degrees. | ||
|
||
The alarm can be configured in comparator and interrupt mode from the | ||
devicetree. In Comparator mode, the OT/UT status bits have a value of 1 when the | ||
temperature rises above the TH value or falls below TL, which is also subject to | ||
|
@@ -75,19 +91,22 @@ it is recommended to perform a read of the configuration/status register to | |
clear the status bits before changing the operating mode. | ||
|
||
The conversions can be manual with the one-shot functionality and automatic with | ||
a set frequency. When powered on, the chip measures temperatures with 1 conv/s. | ||
a set frequency. When powered on, the MAX31827 measures temperatures with 1 | ||
conv/s while the MAX31875 measures temperatures with 0.25 conv/s or 1 conv/4s. | ||
The conversion rate can be modified with update_interval attribute of the chip. | ||
Conversion/second = 1/update_interval. Thus, the available options according to | ||
the data sheet are: | ||
|
||
- 64000 (ms) = 1 conv/64 sec | ||
- 32000 (ms) = 1 conv/32 sec | ||
- 16000 (ms) = 1 conv/16 sec | ||
- 4000 (ms) = 1 conv/4 sec | ||
- 1000 (ms) = 1 conv/sec (default) | ||
- 4000 (ms) = 1 conv/4 sec (MAX31875 default) | ||
- 1000 (ms) = 1 conv/sec (MAX31827 default) | ||
- 250 (ms) = 4 conv/sec | ||
- 125 (ms) = 8 conv/sec | ||
|
||
The MAX31875 only supports the last four values above. | ||
|
||
Enabling the device when it is already enabled has the side effect of setting | ||
the conversion frequency to 1 conv/s. The conversion time varies depending on | ||
the resolution. | ||
|
@@ -97,16 +116,16 @@ available resolutions are: | |
|
||
- 8 bit -> 8.75 ms conversion time | ||
- 9 bit -> 17.5 ms conversion time | ||
- 10 bit -> 35 ms conversion time | ||
- 12 bit (default) -> 140 ms conversion time | ||
- 10 bit (MAX31875 default) -> 35 ms conversion time | ||
- 12 bit (MAX31827 default) -> 140 ms conversion time | ||
|
||
There is a temp1_resolution attribute which indicates the unit change in the | ||
input temperature in milli-degrees C. | ||
|
||
- 1000 mC -> 8 bit | ||
- 500 mC -> 9 bit | ||
- 250 mC -> 10 bit | ||
- 62 mC -> 12 bit (default) - actually this is 62.5, but the fil returns 62 | ||
- 250 mC -> 10 bit (MAX31875 default) | ||
- 62 mC -> 12 bit (MAX31827 default) - actually this is 62.5, but the fil returns 62 | ||
|
||
When chip is in shutdown mode and a read operation is requested, one-shot is | ||
triggered, the device waits for <conversion time> ms, and only after that is | ||
|
@@ -125,7 +144,8 @@ Bus timeout resets the I2C-compatible interface when SCL is low for more than | |
|
||
Alarm polarity determines if the active state of the alarm is low or high. The | ||
behavior for both settings is dependent on the Fault Queue setting. The ALARM | ||
pin is an open-drain output and requires a pullup resistor to operate. | ||
pin is an open-drain output and requires a pullup resistor to operate. The | ||
MAX31875 does not have this feature. | ||
|
||
The Fault Queue bits select how many consecutive temperature faults must occur | ||
before overtemperature or undertemperature faults are indicated in the | ||
|
Oops, something went wrong.