ad_dds: Fix DDS start samples
Browse files Browse the repository at this point in the history
When using a CLK_RATIO > 1 the first n samples(n=CLK_RATIO) after sync, are
noisy. This is because the phase accumulator data is passed to the phase to
amplitude converter, during the phase synchronization step.
  • Loading branch information
AndreiGrozav committed Jan 31, 2022
1 parent bc5974d commit 38f3627
Showing 1 changed file with 13 additions and 3 deletions.
16 changes: 13 additions & 3 deletions library/common/ad_dds.v
Original file line number Diff line number Diff line change
Expand Up @@ -87,9 +87,11 @@ module ad_dds #(

reg [PHASE_DW-1:0] dac_dds_phase_0[1:CLK_RATIO];
reg [PHASE_DW-1:0] dac_dds_phase_1[1:CLK_RATIO];
reg [PHASE_DW-1:0] dac_dds_phase_0_m[1:CLK_RATIO];
reg [PHASE_DW-1:0] dac_dds_phase_1_m[1:CLK_RATIO];
reg [PHASE_DW-1:0] dac_dds_incr_0 = 'd0;
reg [PHASE_DW-1:0] dac_dds_incr_1 = 'd0;
reg sync_min_pulse_m[1:CLK_RATIO];
reg [CLK_RATIO :1] sync_min_pulse_m = 'd0;

// For scenarios where the synchronization signal comes from an external
// source and it is high for a longer period of time, the phase
Expand Down Expand Up @@ -133,6 +135,14 @@ module ad_dds #(
dac_dds_phase_0[i] <= dac_dds_phase_0[i] + dac_dds_incr_0;
dac_dds_phase_1[i] <= dac_dds_phase_1[i] + dac_dds_incr_1;
end

if (dac_data_sync == 1'b1 || sync_min_pulse_m[1]) begin
dac_dds_phase_0_m[i] <= 'd0;
dac_dds_phase_1_m[i] <= 'd0;
end else begin
dac_dds_phase_0_m[i] <= dac_dds_phase_0[i];
dac_dds_phase_1_m[i] <= dac_dds_phase_1[i];
end
end

// phase to amplitude convertor
Expand All @@ -145,9 +155,9 @@ module ad_dds #(
i_dds_2 (
.clk (clk),
.dds_format (dac_dds_format),
.dds_phase_0 (dac_dds_phase_0[i]),
.dds_phase_0 (dac_dds_phase_0_m[i]),
.dds_scale_0 (tone_1_scale),
.dds_phase_1 (dac_dds_phase_1[i]),
.dds_phase_1 (dac_dds_phase_1_m[i]),
.dds_scale_1 (tone_2_scale),
.dds_data (dac_dds_data_s[(DDS_DW*i)-1:DDS_DW*(i-1)]));
end