Expand Up @@ -89,24 +89,33 @@ def _validate_config(self, config_filename) :
critical_config_issues += [message]

# For each supported gas, check that limits PPM configuration is within that sensor's range.
# The limits should be no less than double the range of the sensor. To to illustrate why:
# Say a firefighter experiences [30mins at 1ppm. Then 30mins at 25ppm] and the 1hr limit is 10ppm. Then one
# hour into the fire, this firefighter has experienced an average of 13ppm per hour, well over the 10ppm
# The limits must be less than the range of the sensor. For best reporting, the range should be at least
# two or more times the upper limit and a warning will be produced if this is not the case. To to illustrate
# why: Say a firefighter experiences [30mins at 1ppm. Then 30mins at 25ppm] and the 1hr limit is 10ppm. Then
# one hour into the fire, this firefighter has experienced an average of 13ppm per hour, well over the 10ppm
# limit - their status should be ‘Red’. However, if the range of the sensor is 0-10ppm, then the command center
# would actually see their status as *Green* (not Red or even Yellow) with a 5.5ppm per hour average - seemingly
# well under the limit. Why? Because the sensor would have provided [30mins at 1ppm. Then 30mins at 10ppm] which
# averages to 5.5ppm. For time-weighted average math to give reliable results, the sensor must have a much
# larger range than the limits - 2x being a minimum. If the limit is set at or near the sensor range, a
# firefighter's status would essentially never go red, even if they were well over the limit.
# would actually see their status as *Range Exceeded* (not Red, Yellow or Green), which is not very helpful.
# It's essentially saying "this firefighter's average exposure is unknown - it may be OK or it may not.
# Prometeo can't tell, because the sensors aren't sensitive enough for these conditions". For the firefighter
# to get an accurate report, this sensor would need to have a range of at least 25ppm (and likely more),
# so that exposure could be accurately measured and averaged to 13ppm.
# (Note: the sensor returns *Range Exceeded* to prevent incorrect PPM averages from being calculated.
# e.g. in the above scenario, we do not want to incorrectly calculate an average of 5.5ppm (Green) from a
# sensor showing 30mins at 1ppm and 30mins at 10ppm, the max the sensor can 'see').
for gas in self.SUPPORTED_GASES :
limits = [window[GAS_LIMITS_PROPERTY][gas] for window in self.WINDOWS_AND_LIMITS]
if ( (min(limits) < SENSOR_RANGE_PPM[gas]['min']) or ((max(limits)*2) > SENSOR_RANGE_PPM[gas]['max']) ) :
if ( (min(limits) < SENSOR_RANGE_PPM[gas]['min']) or (max(limits) > SENSOR_RANGE_PPM[gas]['max']) ) :
valid_config = False
message = ("%s : One or more of the '%s' configurations %s is incompatible with the range of the '%s' sensor (min: %s, max: %s)." +
"\nPlease note that sensors must have a much larger range than the limits - 2x being a minimum.") \
message = ("%s : One or more of the '%s' configurations %s is incompatible with the range of the '%s' sensor (min: %s, max: %s).") \
% (config_filename, GAS_LIMITS_PROPERTY, limits, gas, SENSOR_RANGE_PPM[gas]['min'], SENSOR_RANGE_PPM[gas]['max'])
self.logger.critical(message)
critical_config_issues += [message]
if ((max(limits)*2) > SENSOR_RANGE_PPM[gas]['max']) :
# This is valid, but not optimal. Produce a warning.
message = ("%s : One or more of the '%s' configurations %s is very close to the range of the '%s' sensor (min: %s, max: %s)." +
"\nSensors shoud have a much larger range than the limits - e.g. 2x at a minimum .") \
% (config_filename, GAS_LIMITS_PROPERTY, limits, gas, SENSOR_RANGE_PPM[gas]['min'], SENSOR_RANGE_PPM[gas]['max'])
self.logger.warning(message)

# Check there's a valid definition of yellow - should be a percentage between 1 and 99
if not ( (self.YELLOW_WARNING_PERCENT > 0) and (self.YELLOW_WARNING_PERCENT < 100) ) :
Expand Down Expand Up @@ -319,7 +328,7 @@ def _calculate_TWA_and_gauge_for_all_firefighters(self, sensor_log_chunk_df, ff_

# It's essential to know when a sensor value can't be trusted - i.e. when it has exceeded its range (signalled
# by the value '-1'). When this happens, we need to replace that sensor's value with something that
# both 1. identifies it as untrustworthy and 2. also causes calculated values like TWAs and Gauges to be
# both (A) identifies it as untrustworthy and (B) also causes calculated values like TWAs and Gauges to be
# similarly identified. That value is infinity (np.inf). To to illustrate why: Say a firefighter experiences
# [30mins at 1ppm. Then 30mins at 25ppm] and the 1 hour limit is 10ppm. Then 1 hour into the fire, this
# firefighter has experienced an average of 13ppm per hour, well over the 10ppm limit - their status should be