Skip to content

Commit

Permalink
chore(api,robot-server): remove datadog upstreaming (#14385)
Browse files Browse the repository at this point in the history
We won't ever be upstreaming, so remove the endpoints that depend on it.

Closes RET-1420

---------

Co-authored-by: Max Marrone <[email protected]>
  • Loading branch information
sfoster1 and SyntaxColoring authored Jan 30, 2024
1 parent 87eda75 commit fd7ddee
Show file tree
Hide file tree
Showing 5 changed files with 11 additions and 180 deletions.
17 changes: 0 additions & 17 deletions api/src/opentrons/config/advanced_settings.py
Original file line number Diff line number Diff line change
Expand Up @@ -17,7 +17,6 @@
)

from opentrons.config import CONFIG, ARCHITECTURE, SystemArchitecture
from opentrons.system import log_control
from opentrons_shared_data.robot.dev_types import RobotTypeEnum

if TYPE_CHECKING:
Expand Down Expand Up @@ -109,22 +108,6 @@ def __init__(self) -> None:
robot_type=[RobotTypeEnum.OT2, RobotTypeEnum.FLEX],
)

async def on_change(self, value: Optional[bool]) -> None:
"""Special side effect for this setting"""
if ARCHITECTURE == SystemArchitecture.BUILDROOT:
code, stdout, stderr = await log_control.set_syslog_level(
"emerg" if value else "info"
)
if code != 0:
log.error(
f"Could not set log control: {code}: stdout={stdout}"
f" stderr={stderr}"
)
raise SettingException(
f"Failed to set log upstreaming: {code}", "log-config-failure"
)
await super().on_change(value)


class Setting(NamedTuple):
value: Optional[bool]
Expand Down
35 changes: 1 addition & 34 deletions api/src/opentrons/system/log_control.py
Original file line number Diff line number Diff line change
Expand Up @@ -7,7 +7,7 @@
import asyncio
import logging
import subprocess
from typing import Tuple, List
from typing import List


LOG = logging.getLogger(__name__)
Expand Down Expand Up @@ -53,36 +53,3 @@ async def get_records_dumb(selector: str, records: int, mode: str) -> bytes:
)
stdout, _ = await proc.communicate()
return stdout


async def set_syslog_level(level: str) -> Tuple[int, str, str]:
"""
Set the minimum level for which logs will be sent upstream via syslog-ng.
This is the function that actually does the work for
:py:meth:`set_syslog_level_handler`.
Similar to :py:meth:`opentrons.server.endpoints.settings.set_log_level`,
the level should be a python log level like "debug", "info", "warning", or
"error". If it is null, sets the minimum log level to emergency which we
do not log at since there's not really a matching level in python logging,
which effectively disables log upstreaming.
:returns tuple(int, str, str): The error code, stdout, and stderr from
``syslog-ng-ctl``. ``0`` is success,
anything else is failure
"""
with open("/var/lib/syslog-ng/min-level", "w") as ml:
ml.write(level)
proc = await asyncio.create_subprocess_exec(
"syslog-ng-ctl",
"reload",
stdout=asyncio.subprocess.PIPE,
stderr=asyncio.subprocess.PIPE,
)
stdout, stderr = await proc.communicate()
if proc.returncode is None:
snc_reload_result = -1
else:
snc_reload_result: int = proc.returncode # type: ignore
return snc_reload_result, stdout.decode(), stderr.decode()
45 changes: 2 additions & 43 deletions api/tests/opentrons/config/test_advanced_settings.py
Original file line number Diff line number Diff line change
@@ -1,9 +1,9 @@
import pytest
from pytest_lazyfixture import lazy_fixture # type: ignore[import]
from typing import Any, Dict, Generator, Optional, Tuple
from typing import Dict, Generator, Optional
from unittest.mock import MagicMock, patch

from opentrons.config import advanced_settings, ARCHITECTURE, CONFIG
from opentrons.config import advanced_settings, CONFIG
from opentrons_shared_data.robot.dev_types import RobotTypeEnum


Expand Down Expand Up @@ -253,47 +253,6 @@ async def test_restart_required(
assert advanced_settings.is_restart_required() is True


@pytest.mark.parametrize(
argnames=["v", "expected_level"],
argvalues=[
[True, "emerg"],
[False, "info"],
],
)
async def test_disable_log_integration_side_effect(
v: bool, expected_level: str
) -> None:
with patch("opentrons.config.advanced_settings.log_control") as mock_log_control:

async def set_syslog_level(level: Any) -> Tuple[int, str, str]:
return 0, "", ""

mock_log_control.set_syslog_level.side_effect = set_syslog_level
with patch(
"opentrons.config.advanced_settings.ARCHITECTURE",
new=ARCHITECTURE.BUILDROOT,
):
s = advanced_settings.DisableLogIntegrationSettingDefinition()
await s.on_change(v)
mock_log_control.set_syslog_level.assert_called_once_with(expected_level)


async def test_disable_log_integration_side_effect_error() -> None:
with patch("opentrons.config.advanced_settings.log_control") as mock_log_control:

async def set_syslog_level(level: Any) -> Tuple[int, str, str]:
return 1, "", ""

mock_log_control.set_syslog_level.side_effect = set_syslog_level
with patch(
"opentrons.config.advanced_settings.ARCHITECTURE",
new=ARCHITECTURE.BUILDROOT,
):
s = advanced_settings.DisableLogIntegrationSettingDefinition()
with pytest.raises(advanced_settings.SettingException):
await s.on_change(True)


def test_per_robot_true_defaults(mock_read_settings_file_empty: MagicMock) -> None:
with patch.object(advanced_settings, "settings_by_id", new={}):
assert (
Expand Down
48 changes: 8 additions & 40 deletions robot-server/robot_server/service/legacy/routers/settings.py
Original file line number Diff line number Diff line change
Expand Up @@ -11,7 +11,6 @@
dev_types as hardware_dev_types,
)
from opentrons.hardware_control.types import HardwareFeatureFlags
from opentrons.system import log_control
from opentrons_shared_data.pipette import (
mutable_configurations,
types as pip_types,
Expand All @@ -36,7 +35,6 @@
from robot_server.service.legacy.models.settings import (
AdvancedSettingsResponse,
LogLevel,
LogLevels,
FactoryResetOptions,
PipetteSettings,
PipetteSettingsUpdate,
Expand Down Expand Up @@ -167,47 +165,17 @@ async def post_log_level_local(
path="/settings/log_level/upstream",
description=(
"Set the minimum level of logs sent upstream via"
" syslog-ng to Opentrons. Only available on"
" a real robot."
" syslog-ng to Opentrons."
" Removed in robot software v7.2.0."
),
response_model=V1BasicResponse,
responses={
status.HTTP_500_INTERNAL_SERVER_ERROR: {"model": LegacyErrorResponse},
},
response_model=LegacyErrorResponse,
deprecated=True,
)
async def post_log_level_upstream(log_level: LogLevel) -> V1BasicResponse:
log_level_value = log_level.log_level
log_level_name = None if log_level_value is None else log_level_value.name
ok_syslogs = {
LogLevels.error.name: "err",
LogLevels.warning.name: "warning",
LogLevels.info.name: "info",
LogLevels.debug.name: "debug",
}

syslog_level = "emerg"
if log_level_name is not None:
syslog_level = ok_syslogs[log_level_name]

code, stdout, stderr = await log_control.set_syslog_level(syslog_level)

if code != 0:
msg = f"Could not reload config: {stdout} {stderr}"
log.error(msg)
raise LegacyErrorResponse(
message=msg, errorCode=ErrorCodes.GENERAL_ERROR.value.code
).as_error(
status.HTTP_500_INTERNAL_SERVER_ERROR,
)

if log_level_name:
result = f"Upstreaming log level changed to {log_level_name}"
getattr(log, log_level_name)(result)
else:
result = "Upstreaming logs disabled"
log.info(result)

return V1BasicResponse(message=result)
raise LegacyErrorResponse(
message="API Discontinued - log streaming removed",
errorCode=str(ErrorCodes.API_REMOVED),
).as_error(status.HTTP_410_GONE)


@router.get(
Expand Down
46 changes: 0 additions & 46 deletions robot-server/tests/service/legacy/routers/test_settings.py
Original file line number Diff line number Diff line change
Expand Up @@ -26,52 +26,6 @@
from robot_server.persistence import PersistenceResetter, get_persistence_resetter


# TODO(isk: 3/20/20): test validation errors after refactor
# return {message: string}
@pytest.mark.parametrize(
"log_level, syslog_level, expected_message",
[
("error", "err", {"message": "Upstreaming log level changed to error"}),
("ERROR", "err", {"message": "Upstreaming log level changed to error"}),
("warning", "warning", {"message": "Upstreaming log level changed to warning"}),
("WARNING", "warning", {"message": "Upstreaming log level changed to warning"}),
("info", "info", {"message": "Upstreaming log level changed to info"}),
("INFO", "info", {"message": "Upstreaming log level changed to info"}),
("debug", "debug", {"message": "Upstreaming log level changed to debug"}),
("DEBUG", "debug", {"message": "Upstreaming log level changed to debug"}),
(None, "emerg", {"message": "Upstreaming logs disabled"}),
(None, "emerg", {"message": "Upstreaming logs disabled"}),
],
)
def test_post_log_level_upstream(api_client, log_level, syslog_level, expected_message):
with patch("opentrons.system.log_control.set_syslog_level") as m:
m.return_value = 0, "stdout", "stderr"
response = api_client.post(
"/settings/log_level/upstream", json={"log_level": log_level}
)
body = response.json()
assert response.status_code == 200
assert body == expected_message
m.assert_called_once_with(syslog_level)


def test_post_log_level_upstream_fails_reload(api_client):
log_level = "debug"

with patch("opentrons.system.log_control.set_syslog_level") as m:
m.return_value = 1, "stdout", "stderr"
response = api_client.post(
"/settings/log_level/upstream", json={"log_level": log_level}
)
body = response.json()
assert response.status_code == 500
assert body == {
"message": "Could not reload config: stdout stderr",
"errorCode": "4000",
}
m.assert_called_once_with(log_level)


def test_get_robot_settings(api_client, hardware):
Conf = make_dataclass("Conf", ["a", "b", "c"])
hardware.config = Conf(a="test", b="this", c=5)
Expand Down

0 comments on commit fd7ddee