Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Revert "Fixed #572 : allow long duration hydro reservoir" #630

Merged
merged 1 commit into from
Feb 14, 2024
Merged
Show file tree
Hide file tree
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
1 change: 0 additions & 1 deletion CHANGELOG.md
Original file line number Diff line number Diff line change
Expand Up @@ -19,7 +19,6 @@ and this project adheres to [Semantic Versioning](https://semver.org/spec/v2.0.0
- Fix factor of 0.5 when writing out transmission losses. (#480)
- Fix summation error when a set of hours is empty (in thermal_commit.jl).
- Fix access to eELOSSByZone expr before initialization (#541)
- Fix modeling of hydro reservoir with long duration storage (#572).

### Changed

Expand Down
11 changes: 7 additions & 4 deletions src/model/resources/hydro/hydro_inter_period_linkage.jl
Original file line number Diff line number Diff line change
Expand Up @@ -54,6 +54,8 @@ function hydro_inter_period_linkage!(EP::Model, inputs::Dict)

STOR_HYDRO_LONG_DURATION = inputs["STOR_HYDRO_LONG_DURATION"]

START_SUBPERIODS = inputs["START_SUBPERIODS"]

hours_per_subperiod = inputs["hours_per_subperiod"] #total number of hours per subperiod

dfPeriodMap = inputs["Period_Map"] # Dataframe that maps modeled periods to representative periods
Expand All @@ -79,20 +81,21 @@ function hydro_inter_period_linkage!(EP::Model, inputs::Dict)
# Modified initial state of storage for long-duration storage - initialize wth value carried over from last period
# Alternative to cSoCBalStart constraint which is included when not modeling operations wrapping and long duration storage
# Note: tw_min = hours_per_subperiod*(w-1)+1; tw_max = hours_per_subperiod*w
@constraint(EP, cHydroReservoirLongDurationStorageStart[w=1:REP_PERIOD, y in STOR_HYDRO_LONG_DURATION],
@constraint(EP, cSoCBalLongDurationStorageStart_H[w=1:REP_PERIOD, y in STOR_HYDRO_LONG_DURATION],
EP[:vS_HYDRO][y,hours_per_subperiod*(w-1)+1] == (EP[:vS_HYDRO][y,hours_per_subperiod*w]-vdSOC_HYDRO[y,w])-(1/dfGen[y,:Eff_Down]*EP[:vP][y,hours_per_subperiod*(w-1)+1])-EP[:vSPILL][y,hours_per_subperiod*(w-1)+1]+inputs["pP_Max"][y,hours_per_subperiod*(w-1)+1]*EP[:eTotalCap][y])

# Storage at beginning of period w = storage at beginning of period w-1 + storage built up in period w (after n representative periods)
## Multiply storage build up term from prior period with corresponding weight
@constraint(EP, cHydroReservoirLongDurationStorage[y in STOR_HYDRO_LONG_DURATION, r in MODELED_PERIODS_INDEX],
@constraint(EP, cSoCBalLongDurationStorage_H[y in STOR_HYDRO_LONG_DURATION, r in MODELED_PERIODS_INDEX],
vSOC_HYDROw[y, mod1(r+1, NPeriods)] == vSOC_HYDROw[y,r] + vdSOC_HYDRO[y,dfPeriodMap[r,:Rep_Period_Index]])

# Storage at beginning of each modeled period cannot exceed installed energy capacity
@constraint(EP, cHydroReservoirLongDurationStorageUpper[y in STOR_HYDRO_LONG_DURATION, r in MODELED_PERIODS_INDEX],
@constraint(EP, cSoCBalLongDurationStorageUpper_H[y in STOR_HYDRO_LONG_DURATION, r in MODELED_PERIODS_INDEX],
vSOC_HYDROw[y,r] <= dfGen[y,:Hydro_Energy_to_Power_Ratio]*EP[:eTotalCap][y])

# Initial storage level for representative periods must also adhere to sub-period storage inventory balance
# Initial storage = Final storage - change in storage inventory across representative period
@constraint(EP, cHydroReservoirLongDurationStorageSub[y in STOR_HYDRO_LONG_DURATION, r in REP_PERIODS_INDEX],
@constraint(EP, cSoCBalLongDurationStorageSub_H[y in STOR_HYDRO_LONG_DURATION, r in REP_PERIODS_INDEX],
vSOC_HYDROw[y,r] == EP[:vS_HYDRO][y,hours_per_subperiod*dfPeriodMap[r,:Rep_Period_Index]] - vdSOC_HYDRO[y,dfPeriodMap[r,:Rep_Period_Index]])


Expand Down
17 changes: 2 additions & 15 deletions src/model/resources/hydro/hydro_res.jl
Original file line number Diff line number Diff line change
Expand Up @@ -70,12 +70,6 @@ function hydro_res!(EP::Model, inputs::Dict, setup::Dict)
HYDRO_RES = inputs["HYDRO_RES"] # Set of all reservoir hydro resources, used for common constraints
HYDRO_RES_KNOWN_CAP = inputs["HYDRO_RES_KNOWN_CAP"] # Reservoir hydro resources modeled with unknown reservoir energy capacity

STOR_HYDRO_SHORT_DURATION = inputs["STOR_HYDRO_SHORT_DURATION"]
representative_periods = inputs["REP_PERIOD"]

START_SUBPERIODS = inputs["START_SUBPERIODS"]
INTERIOR_SUBPERIODS = inputs["INTERIOR_SUBPERIODS"]

# These variables are used in the ramp-up and ramp-down expressions
reserves_term = @expression(EP, [y in HYDRO_RES, t in 1:T], 0)
regulation_term = @expression(EP, [y in HYDRO_RES, t in 1:T], 0)
Expand Down Expand Up @@ -113,14 +107,6 @@ function hydro_res!(EP::Model, inputs::Dict, setup::Dict)

### Constratints ###

if representative_periods > 1 && !isempty(inputs["STOR_HYDRO_LONG_DURATION"])
CONSTRAINTSET = STOR_HYDRO_SHORT_DURATION
else
CONSTRAINTSET = HYDRO_RES
end

@constraint(EP, cHydroReservoirStart[y in CONSTRAINTSET,t in START_SUBPERIODS], EP[:vS_HYDRO][y,t] == EP[:vS_HYDRO][y, hoursbefore(p,t,1)]- (1/dfGen[y,:Eff_Down]*EP[:vP][y,t]) - vSPILL[y,t] + inputs["pP_Max"][y,t]*EP[:eTotalCap][y])

### Constraints commmon to all reservoir hydro (y in set HYDRO_RES) ###
@constraints(EP, begin
### NOTE: time coupling constraints in this block do not apply to first hour in each sample period;
Expand All @@ -129,7 +115,8 @@ function hydro_res!(EP::Model, inputs::Dict, setup::Dict)
# DEV NOTE: Last inputs["pP_Max"][y,t] term above is inflows; currently part of capacity factors inputs in Generators_variability.csv but should be moved to its own Hydro_inflows.csv input in future.

# Constraints for reservoir hydro
cHydroReservoirInterior[y in HYDRO_RES, t in INTERIOR_SUBPERIODS], EP[:vS_HYDRO][y,t] == (EP[:vS_HYDRO][y, hoursbefore(p,t,1)]- (1/dfGen[y,:Eff_Down]*EP[:vP][y,t]) - vSPILL[y,t] + inputs["pP_Max"][y,t]*EP[:eTotalCap][y])
cHydroReservoir[y in HYDRO_RES, t in 1:T], EP[:vS_HYDRO][y,t] == (EP[:vS_HYDRO][y, hoursbefore(p,t,1)]
- (1/dfGen[y,:Eff_Down]*EP[:vP][y,t]) - vSPILL[y,t] + inputs["pP_Max"][y,t]*EP[:eTotalCap][y])

# Maximum ramp up and down
cRampUp[y in HYDRO_RES, t in 1:T], EP[:vP][y,t] + regulation_term[y,t] + reserves_term[y,t] - EP[:vP][y, hoursbefore(p,t,1)] <= dfGen[y,:Ramp_Up_Percentage]*EP[:eTotalCap][y]
Expand Down
Loading