The smart nodes was created to control smart home devices like lights, power outlets shutter and some more. This nodes are designed to work with the node-red-contrib-knx-ultimate but it could also work with other smart technologies.
The knx binary input and output/switching modules should be configured very stupid. Closing a binary input should output 1 and releasing 0.
Same for the output/switching modules, 1 should turn on and 0 turn off. That makes it easy to count the presses or check for short and long presses.
Some node has to filter out the binary inputs if they goes to 0 or in other words, if msg.payload == false
. Please see the internal node documentation then this signals are ignored. As an example sending msg.topic = "toggle"
for pressing and releasing an button would toggle the output twice.
Sometimes one source node should be connected to multiple smart nodes which requires different topics.
To avoid requiring many change nodes, the smart nodes are using a special msg.topic
notation. You can always send topics in the format name#number
, e.g. toggle#1
.
Smart nodes that requires a name are using only the name part. the # and the number are ignored and optional. Smart nodes that requries a number will only use the number, the name and # is also ignored and optional.
This is usefull when one node provides information for example to a light control node and also to a logic node.
This file only describes the general function of the node. See the documentation shown in NodeRed to find out how to use them, or see the included example flows.
This smart nodes are still in development and can have breaking changes. So please always take a look in the Changelog file.
I spent a lots of hours in this project. If you like it, you can support my work in different ways:
- Report bugs.
- Create pull requests.
- Name tipps and tricks if you see any improvement.
- Donate via Paypal.
This node is able to control a light or a power outlet.
- Auto turn off the light after a fixed time.
- Auto turn off the light with a custom time which is part of the message object.
- Toggle light between on and off.
- Can be activated by motion sensors.
- Has an alarm on function to go to a specific state (on or off) when the alarm is activated.
- Has an alarm off function to go to a specific (on, off, the last or the last sended) when the alarm is deactivated.
This node is able to control a shutter. There is no support for slats and it is also not planned as I don't need them, but feel free to send a pull request.
- One button control which switch between
up
,stop
,down
,stop
. - Two button control for each direction
up and stop
anddown and stop
. - Send direct position the shutter should go to.
- Stop shutter immediately.
- Has an alarm on function to go to a specific state (Open or close) when the alarm is activated.
- Has an alarm off function to restore a specific state when the alarm gets deaktivated.
This node is tracking the state of multiple outputs and controls them by switching to multiple defined scenes.
- An input message could name multiple scenes that should be iterated one by one by receiving the same message multiple times
This node can control multiple light/scene controls or shutter controls at the same time
- Take care that multiple light/scene controls are turned of if any of them is one before executing a toggle command. This is helpful to avoid turning one light on and the other off.
- The same is used for shutters with the up_stop or down_stop commands. A toggle is not supported, it will only be forwarded.
This node is used to detect a short or a long press. The time can be configured in this node.
- Imediately send a message to the long press output when the time is reached. It is not waiting until the button is released.
This node is used to detect multiple presses on a button. The max wait time between presses can be configured in this node. You can also choose 2-4 press detection.
- Imediately send a message to the last output when the max presses are reached. It is not waiting until the button is released.
This node is checking if the input value reachs a defined value until the upper message is send. When the lower level is reached, the lower masssage will be send
- The state can be saved between NodeRed restarts.
- The last message can automatically be sent 10 seconds after a deployment.
This node can be used for AND, OR and XOR logics.
- All input values could be individual converted as well as the output messsage.
- A NOT logic is possible when selecting 1 input and convert the output.
- The setpoint and hysteresis value can be changed in runtime.
- The state can be saved between NodeRed restarts.
- The last message can automatically be sent 10 seconds after a deployment.
This node can be used for getting the following types of values: Minimum, Maximum, Sum, Difference, Absolute Value, Absolute Difference, Average and Running average.
- All input values could be individual converted as well as the output messsage.
- A NOT logic is possible when selecting 1 input and convert the output.
- The state can be saved between NodeRed restarts.
- The last message can automatically be sent 10 seconds after a deployment.
This node can compare 2 values with the following operators: < <= == >= > !=
- Can compare also texts like js would do.
- The state can be saved between NodeRed restarts.
- The last message can automatically be sent 10 seconds after a deployment.
This node can delay incomming messages.
- Different times for
msg.payload = true
andmsg.payload = false
. - Delays can be changed in runtime.
- The state can be saved between NodeRed restarts.
- The last message can automatically be sent 10 seconds after a deployment.
This node can control if an incomming message should be forwarded or not.
- The forwarding can be enabled or disabled in runtime.
- The state can be saved between NodeRed restarts.
- The last message can automatically be sent 10 seconds after a deployment.
This node can send a defined message on defined times.
- The weekdays and the time can be selected as a trigger.
- Multiple trigger and messages can be defined in one node.
- The scheduler can be activated or deactivated in runtime.
- The state can be saved between NodeRed restarts.
- The last message can automatically be sent 10 seconds after a deployment.
This node parses a text and performs actions to the selected and matching smart nodes
- Control light and scenes (only on or off) in german and english.
- Control shutter in german and english.
Text in [ Braces ] is optional
Room names that has to be entered in the nodes are in code
style.
- Turn on [the light in] the
living room
and thekitchen
off. - Open [the shutter in] the
kitchen
and turnstudio
off. - Close [the shutter in the]
sleeping
room. Living room
to 10 %.- Turn on
living room
except thecouch
light.
- Sends debug message to output.
This node can control a mixing valve to get the required tput temperature. It is working for heating and cooling.
- Define target temperature.
- Support heating and cooling.
- Define off mode to do nothing, open or close the valve.
This node calculates the needed flow temperature regarding to the target room temperature and the current outside temperature.
- Define slope and offset values.
- Limit flow temperature with min and max values.
- Preview of different curves in the node editor.
This node countes up and down within a specified range.
- Define min, max and step values.
- Set to a specific value
- Increment and decrement by default or by a given value.