Skip to content

Avnet-Fujikura 5G mmWave Phased Array Antenna Module Development Platform

Notifications You must be signed in to change notification settings

Avnet/Fujikura-beamforming-TaskAB

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

23 Commits
 
 
 
 

Repository files navigation

5G mmWave Task-A/B PAAM Development Platform User Guide


Note!! This document is not the latest and it has been superseded.
Please see the 5G mmWave Type-C PAAM Development Platform User Guide.

Document Control

Document Version: 2.0

Document Date: 6/12/2024

Version History

Version Date Comment
1.1 Jun 12, 2024 Public release with RFSoC Explorer 3.1
1.0 Dec 5, 2023 Initial public release with RFSoC Explorer 3.0

Table of contents

  1. Overview

  2. AMD ZCU208 Evaluation Board

  3. uSD Card Preparation

  4. Connecting the ZCU208 to your PC

    4.1. Serial Port Connection

    4.2. Getting the IP Address

    4.3. Setting a Static IP Address

  5. Connecting the Fujikura PAAM Daughtercard

    5.1. Connecting Power and the Digital Interface

    5.2. Using the C# Test GUI (optional)

    5.3. Connecting the Analog Path and Instruments

  6. Using the CLK-104 Module

  7. Installing MATLAB and Avnet RFSoC Explorer®

    7.1. Setting up Python Support in Matlab

    7.1.1 Setting the Python version in MATLAB

  8. Testing the RFSoC Explorer Digital Interface

    8.1 ADC and DAC Control Tab

  9. Renesas 8V97003 18 GHz RF Synthesizer

  10. Fixture for the Daughtercard

    10.1 Daughtercard installation on the fixing stand

  11. Over-the-air Testing with Rohde & Schwarz ATS800B compact antenna test range

  12. Terminology

Figures

Figure 1 – 5G mmWave PAAM Development Platform

Figure 2 – AMD ZCU208 Evaluation Board

Figure 3 – [Completed boot sequence 10](#_Ref141963341)

Figure 4 – [Ribbon cables between the ZCU208 and the PAAM Daughtercard 14](#_Toc146045116)

Figure 5 – [Board User Interface to the CLK-104 Module 20](#_Toc146045117)

Figure 6 – [Renesas 8V97003 RF Synthesizer in Fractional Mode 25](#_Toc146045118)

Figure 7 – [Renesas 8V97003 RF Synthesizer in Integer Mode 26](#_Toc146045119)

1) Overview

Avnet's 5G mmWave PAAM Development Platform combines the AMD ZCU208 evaluation kit with the Fujikura PAAM Daughtercard.

AMD's ZCU208 Zynq UltraScale+ RFSoC evaluation kit features the ZU48DR device:

  • Cortex®-A53 core,

  • Cortex-R5 core and, amongst other peripherals, integrates

  • eight 14-bit 5GSPS ADCs,

  • and eight 14-bit 10GSPS* DACs.

The Fujikura PAAM Daughtercard is an assembly that features

  • the Fujikura PAAM as well as a number of peripherals, such as

  • a programmable Renesas RF synthesizer

  • an EEPROM,

  • ADCs,

  • a DAC.

  • digital step attenuators for IF

Figure 1 – 5G mmWave PAAM Development Platform

2) AMD ZCU208 Evaluation Board

For instructions on setting up the ZCU208, please refer to the ZCU208 User Guide and the guide for ZCU208 Software Install and Board Setup. Some relevant components for the instructions below are marked in this diagram.

Figure 2 – AMD ZCU208 Evaluation Board

(1) Marks the uSD card slot J23

(2) Marks the micro USB Type B serial cable connector J24 that goes to the PC

(3) Marks the Ethernet cable connector P1

(4) Marks the power connector J50 and (5) marks the power ON/OFF switch SW15

(6) Marks the FMC+ connector J28 for the adapter card for cabling to the Fujikura card

3) uSD Card Preparation

A Micro SD (uSD) card ships with the ZCU208. A different uSD card can be used, but it is important to know that some uSD cards do not work well with AMD development boards. Please consult this link for list of SD cards that have been tested with Zynq UltraScale+ MPSoC.

Follow these steps to load a custom SD card boot image for the ZCU208, allowing it to control the Fujikura PAAM Daughtercard via RFSoC Explorer.

  1. Remove the SD card from slot J23 on the ZCU208 and insert into your PC. Then format it as FAT using a tool like SD Memory Card Formatter.

  2. Download the boot image archive zip file from the public repository at ZCU208 uSD Card.

  3. Unzip the archive to the root level of the SD card.

  4. Safely eject the SD card from the PC and replace it in the J23 slot on the ZCU208.

4 Connecting the ZCU208 to your PC

4.1 Serial Port Connection

Connect a micro USB Type B to USB Type A serial comms cable between J24 on the ZCU208 and a USB port on your PC.

If your PC does not automatically detect the new COM ports associated with the ZCU208, you should consult the guide for ZCU208 Software Install and Board Setup.

In summary:

  1. If your PC does not automatically detect and enumerate new COM ports for the ZCU208, you may need to install FTDI Virtual COM Port (VCP) drivers.

  2. Three new COM ports for the ZCU208 should appear in the Windows Device Manager. Each of these COM ports should show that it is using the FTDI driver:

  3. These 3 COM ports are usually in numerical order and it is important that of these 3 ports, you select the COM port with the lowest value when connecting to the serial port for the Zynq device on the ZCU208. Here that port is COM8, but on your PC it could be 3 other numbers that show up, and you should pick the lowest one.

  4. Open a serial terminal emulator (e.g. TeraTerm) on your PC.
    Make sure you select 115200 as the Baud rate and that you picked the correct COM port.

  5. Connect the ZCU208 power supply to an outlet and to connector J50. Then power ON the board using SW15.

  6. The serial terminal emulator should start showing the boot log as below.

  7. When the boot process completes, this should be the output. Note that the displayed IP address will not necessarily be one that can be used. We will discuss setting the IP address in the next section.

Figure 3 – Completed boot sequence

4.2 Getting the IP Address

  1. Connect an Ethernet cable from P1 on the ZCU208 to the local network that your PC is on.

  2. On the serial port terminal that is shown in Figure 3, hit Enter so that a login prompt will be shown. Enter root for the login name and then again root for the password.

  3. Enter ifconfig . Note the IP address, since you will use this address to connect to the board from your PC.

  4. From a Command Prompt on your PC, verify that you can connect to the ZCU208 by pinging the IP address above.

4.3 Setting a Static IP Address

  1. If you intend to connect the ZCU208 to an Ethernet port on your PC directly, you may have to edit the autostart.sh file on the ZCU208’s uSD card first.

  2. Power the ZCU208 off using SW15 and remove the uSD card from its slot, J23.

  3. Insert the uSD card into your PC and open autostart.sh in a text editor.
    Note: Make sure you are using a Linux-compatible editor like Notepad++ so that lines are terminated with a LF character only.

  4. Set USE_DHCP=false

  5. Safely eject the SD card from the PC and replace it in the J23 slot on the ZCU208 and turn the ZCU208 power switch SW15 ON

  6. The application auto-start function creates an IP connection for the board at an address like 169.254.10.2. To use a different IP address, simply modify the IPADDR field in the autostart.sh file.

  7. Set a static IP for your host PC’s Local Ethernet adapter. Make sure your PC and the board are on the same subnet and gateway. See the example below.

5 Connecting the Fujikura PAAM Daughtercard

5.1 Connecting Power and the Digital Interface

Some relevant components for the instructions below are marked in this diagram.

Figure 4 – Ribbon cables between the ZCU208 and the PAAM Daughtercard

(1) Marks the ZCU208 power ON/OFF switch SW15

(2) Marks the fan power header CN14

(3) Shows the EVK Conversion Card plugged into the FMC+ connector J28 on the ZCU208

(4) Marks the two ribbon cable assemblies with the FireFly connectors

(5) Marks the Ach connectors CN1 on the Conversion Card and on the PAAM Daughtercard

(6) Marks the Bch connectors CN3 on the Conversion Card and on the PAAM Daughtercard

(7) Marks the Daughtercard power connector CN10

(8) Marks the Daughtercard power ON/OFF switch SW1

  1. Make sure to power off the ZCU208 first, using the ON/OFF switch SW15.

  2. On the PCB side that is opposite to the where the PAAM is mounted*, there is a large cooling fan** with a 3-wire cable assembly (red, black and yellow). The red and black wires end in a 2-position header socket, while the yellow wire is not used. Push this header socket onto CN14 that is marked “FAN”. The black side goes to the GND pin, next to the SMA connector CN7, while the red side goes to the 12V pin***.

  3. Plug the Fujikura PAAM EVK Conversion Card into J28, the FMC+ connector on the ZCU208. Two screws can be used to secure it if necessary.

  4. Two ribbon cable assemblies with Samtec FireFly connectors are used to transfer the digital signals between the EVK Conversion Card and the PAAM Daughtercard.

This short video (at 0:58) also shows how this is done.

  1. There are two ribbon cables. First connect CN1 (marked Ach) on the EVK Conversion Card to CN1 (also marked Ach) on the PAAM Daughtercard.

  2. Then connect CN3 (marked Bch) on the EVK Conversion Card to CN3 (also marked Ach) on the PAAM Daughtercard.

  3. Connect the 12V power supply that comes with the PAAM EVK to CN10 on the PAAM Daughtercard.

  4. First turn on the ZCU208 power supply. Then turn on the Daughtercard power supply with its ON/OFF switch SW1. The fan should make a loud noise, indicating that it works.

NOTE

* Do not touch the PAAM surface. If the antenna is scratched, the expected performance may not be achieved.

** Do not remove the heatsink. If the heatsink is removed even once, the heat dissipation performance cannot be guaranteed.

***Incorrect connection will short the power supply.

5.2 Using the C# Test GUI (optional)

Avnet created a custom test utility that can be used to verify that the peripherals on the Fujikura PAAM Daughtercard work correctly. These peripherals are:

  • The power supply regulators

  • An EEPROM for storing board parameters and version information

  • Five attenuators (4 for the Tx and Rx H and V paths and one for the PLL output)

  • A 4-channel DAC for setting trim values for the power supply rails

  • Four 8-channel ADC’s

  • A Renesas 8V97003 PLL for creating the LO if an external input is not provided

A Linux utility, fjk_tcp, runs on the ZCU208 and processes communications from a host in the form of JSON strings via Ethernet port 8083. It is important to note that only one host utility, i.e. either RFSoC Explorer or the C# GUI, can use that port. So only one of the two can be used at a time.

A link for downloading the C# test utility can be requested from Avnet. It consists of a single Windows executable and two Newtonsoft files for JSON support. They can be stored anywhere on your PC.

The utility can be run by double-clicking Fujikura TCP Host.exe. When the program closes, a Fujikura TCP Host.ini file that stores some of the user’s selections is saved in the same directory.

Make sure that the ZCU208 is booted, as shown in Figure 3.

The first time you run the C# GUI, you will have to enter the ZCU208 IP address, before clicking Open TCP Port.

On the “Power and Attenuation” tab that opens, click Get Versions and make sure you receive a response.

All communication with the ZCU208 is via JSON strings. Note that you can see a history of commands and responses on the Comms tab. You can clear the history by clicking on Clear Text Boxes.

Un-checked boxes mean that the status is unknown. If you close the GUI and re-start it, you can request the ZCU208 status by clicking the Read Status button. If a value was previously set, it should show in the GUI.

5.3 Connecting the Analog Path and Instruments

TBD

6 Using the CLK-104 Module

The ZCU208 kit includes a CLK-104 module that plugs into J101. There are a few clock sources on this module and the LMK04828 output is available as OUTPUT_REF on the J10 SMA connector. This can be connected to the PLL input REF_EXT, which is CN12 on the Fujikura Daughtercard.

The LMK04828 is managed by a TI MPS430 System Controller. The user interface to the System Controller is via one of the USB serial ports (one of those ports is used for the Linux terminal).

The software used for this interface is the ZCU208 Board User Interface. The installer
rdf0562-zcu208-bit-c-2020-1.zip can be downloaded from
https://www.xilinx.com/products/boards-and-kits/zcu208.html#documentation .

After unzipping the file, run .\zcu208_bit\ BoardUI\BoardUI.exe.

Under File/Select the system controller port, select a port. Typically, this enumerates as the highest number of the 3 ZCU208 USB COM ports.

The way to make sure that communications with the CLK-104 module works is to click Check-CLK-104.

We want to program the LMK04828 to output 122.88MHz. This is done as follows:

  • In the release directory there is a file
    ZCU208 CLK-104 Card\245M76_PL_122M88_SYSREF_7M68_OUTREFCLK_122M88_TCS.txt

Place this file in the folder
.\zcu208_bit\BoardUI\tests\ZCU208\clockFiles\lmk04828\

  • As in the diagram below, select the LMK04828 file to program.

  • The clock can be reset (turned off) by clicking Reset LMK04828.

  • The clock can be programmed by clicking Set LMK04828 Params. While being programmed, the D10 LED on the CLK-104 card will go off, briefly flash a few times and then stay on.

Figure 5 – Board User Interface to the CLK-104 Module

7 Installing MATLAB and Avnet RFSoC Explorer®

Avnet RFSoC Explorer provides native connection to MATLAB ® and Simulink ®, featuring graphical control of the platform and intuitive APIs for programmatic access.

Your computer will need the following MathWorks software.

  • MATLAB (supported versions)

  • DSP System Toolbox

  • Fixed-Point Designer

  • Communications Toolbox

  • Signal Processing Toolbox

  • Install one of the following support packages from the MATLAB Add-On Manager

  • Communications Toolbox Support Package for Xilinx Zynq-Based Radio

  • HDL Coder Support Package for Xilinx RFSoC Devices

  • SoC Blockset Support Package for Xilinx Devices

Optional toolboxes for working with standards-compliant waveforms in RFSoC Explorer

  • LTE Toolbox (optional)

  • 5G Toolbox (optional)

Get a Free MATLAB Trial Package for RFSoC

RFSoC Explorer installs easily using the MATLAB Add-Ons store.

  1. From MATLAB > Add-Ons, search for Avnet RFSoC Explorer and click install

  2. From MATLAB > Add-Ons, search for Communications Toolbox Support Package for Xilinx Zynq-Based Radio and click install

  3. If prompted, click Setup Later

7.1 Setting up Python Support in Matlab

RFSoC Explorer has been tested with Python 3.9.13, but earlier/later releases may also work.

After installing Python, the following commands are needed to install the support libraries that are being used:

py -m pip install --user --upgrade pip

py -m pip install pyserial

py -m pip install numpy

py -m pip install spectrum

py -m pip install pandas

py -m pip install openpyxl

py -m pip install pyvisa

7.1.1 Setting the Python version in MATLAB

  1. First, check whether the correct Python version is supported in your MATLAB installation by entering:
>> pyenv

ans =
    PythonEnvironment with properties:
       Version: "3.9"
    Executable: "C:\Users\Name\AppData\Local\Programs\Python\Python39\python.exe"
       Library: "C:\Users\Name\AppData\Local\Programs\Python\Python39\python39.dll"
          Home: "C:\Users\Name\AppData\Local\Programs\Python\Python39"
        Status: NotLoaded
 ExecutionMode: InProcess

The response above is for a valid Python environment; the important property is 'Executable'.

  1. If these are not as expected, enter:
>> [~, exepath\] = system("where python")

    exepath =
    C:\Users\Name\AppData\Local\Programs\Python\Python39\python.exe
    C:\Users\Name\AppData\Local\Microsoft\WindowsApps\python.exe

The valid path to the version 3.9 executable is in 'Python39' folder.

  1. Now enter (using the valid path above):
>> pyenv('Version', 'C:\Users\Name\AppData\Local\Programs\Python\Python39\python.exe')

ans =
    PythonEnvironment with properties:
       Version: "3.9"
    Executable: "C:\Users\Name\AppData\Local\Programs\Python\Python39\python.exe"
       Library: "C:\Users\Name\AppData\Local\Programs\Python\Python39\python39.dll"
          Home: "C:\Users\Name\AppData\Local\Programs\Python\Python39"
        Status: NotLoaded
 ExecutionMode: InProcess

8) Testing the RFSoC Explorer Digital Interface

In MATLAB, enter:

>> Avnet_RFSoC_Explorer('startup', 'board_id', 7)

This should bring up the RFSoC Explorer GUI. If you have not connected to a ZCU208 before, the IP address should be red and “DISCONNECTED, as below’.

If you have entered an IP address before, the utility will try to connect automatically. If connection was successful, the IP address will be black,

and it will be available in the drop-down for future sessions.

Once connected:

  1. Go to the Fujikura PAAM tab.

  2. Click Init .

  3. RFSoC Explorer should now start using Python scripts and JSON messages to initialize the PAAM Daughtercard. If it cannot communicate with the PAAM, you will get a dialog to apply PAAM power. Make sure that the Daughtercard power ON/OFF switch SW1 is in the ON position (towards CN14) so that you can hear the fan. Then click OK to continue.

  1. RFSoC Explorer should now continue initializing the PAAM. This can take 40 seconds to complete.

  1. When initialization is complete, the dialog box will display the steps taken, followed by Successfully initialized PAAM Daughtercard with default settings and the printout from committing those settings to the PAAM.

  1. You can now make changes to some PAAM controls. In the image below Tx Vertical Polarization is turned on and the DSA value is changed to 5. Note that the Send to PAAM button has turned green. These changes on the GUI will only take effect on the hardware once Send to PAAM is clicked.

  1. Send to PAAM will turn grey again and updated PAAM settings will be displayed in the dialog box, and the image of the PAAM will be updated to show the active elements on the array.

  1. If you wish to see the 2D elevation and azimuth plots or a 3D plot which approximate the beampattern of an array of 5G antenna elements, check the boxes next to the 2D/3D Beam Angle Plot text before sending the settings to the PAAM.

    NOTE: Both the Phased Array System Toolbox and the Antenna Toolbox must be installed to create plots.

8.1 ADC and DAC Control Tab

The Fujikura PAAM Daughtercard includes the ability to measure and adjust all system voltage rails by way of onboard ADCs and DACs. The ADC/DAC tab allows for reading ADC values and writing DAC values. As part of a successful initialization of the PAAM by Avnet RFSoC Explorer, default values will be written to enable the DAC channels.

After successfully initializing the Fujikura PAAM daughtercard, the "Read ADCs" button will turn red, indicating that the ADC channels are available for reading. Reading the ADC values before initialization will not guarantee correct readback.

Each of the rails has a text field in which to enter the desired output voltage, which will then send a command to the app running on the AMD Zynq RFSoC Processing Subsystem (PS) to set the appropriate trim value.

NOTE: Most users will not need to adjust the DAC values.

9) Renesas 8V97003 18 GHz RF Synthesizer

The Fujikura PAAM Daughtercard can connect an external signal through SMA connector (CN7) to provide the local oscillator (LO) to the PAAM FCIC for up/down conversion between the intermediate frequency of the ZCU208 RFSoC DAC/ADC in TX/RX operation.

Alternatively, an on-board Renesas 8V97003 RF synthesizer (aka ‘PLL’) can generate the LO for autonomous operation of the system.

The RF synthesizer is fully programmable in fractional or integer modes. See Renesas 8v97003 Performance optimization guidelines

Avnet RFSoC Explorer will adjust the PLL feedback parameters and the IF frequency to meet the desired RF frequency, as per the following equations:

$$Fpfd = PLL\ input\ frequency \times \frac{2^{PLL\ input\ doubler(D)}}{PLL\ Input\ divider(R)}$$

$$VCO\ frequency = Fpfd\ \times \left( N_{integer} + N_{fractional}/MOD \right)$$

$$RF\ frequency = VCO\ frequency\ \times 4 + IF\ frequency$$

Figure 6: Renesas 8V97003 RF Synthesizer in Fractional Mode

Example RF synthesizer settings in fractional mode for desired RF frequency = 28 GHz:

RF Frequency 28.000 GHz Desired RF frequency, set by user
PLL input frequency 122.880 MHz Set by user
PLL input doubler(D) On Set by user
PLL input divider(R) = 1 1 Set by user
IF Frequency 3.00000 GHz Adjusted by RFSoC Explorer for desired RF frequency
VCO Frequency 6.25000 GHz Calculated by RFSoC Explorer for desired RF frequency

Figure 7: Renesas 8V97003 RF Synthesizer in Integer Mode

Example RF synthesizer settings in integer mode for desired RF frequency = 28 GHz:

RF Frequency 28.000 GHz Desired RF frequency, set by user
PLL input frequency 122.880 MHz Set by user
PLL input doubler(D) On Set by user
PLL input divider(R) = 1 1 Set by user
IF Frequency 3.42400 GHz Adjusted by RFSoC Explorer for desired RF frequency
VCO Frequency 6.14400 GHz Calculated by RFSoC Explorer for desired RF frequency

10) Fixture for the Daughtercard

10.1 Daughtercard installation on the fixing stand

The Fujikura PAAM Daughtercard can be used with the fixing stand to measure RF characteristics if necessary. Securely fix the fixing stand to your measurement system before connecting some coaxial cables and power cable. If the installation work is carried out while the fixing stand is not sufficiently fixed, the evaluation board may tip over and damage the operator or your property.

  1. Attach the 4 hexagonal posts to the fixing base using screws with a tightening torque of 0.315 N·m (red circle).*

  2. Attach the Daughtercard to the hexagonal post attached to the fixing stand using screws with cap.

NOTE

*If the fixing stand screws shown in picture are loose (blue circle, yellow circle), retighten them with a tightening torque of 0.315 N·m for blue circle or 0.75 N·m for yellow circle.

CAUTION

The radio waves emitted from the PAAM may have a negative effect on the human body, so do not stand within a 1 m radius in front of the PAAM while radio waves are being emitted.

11) Over-the-air Testing with Rohde & Schwarz ATS800B compact antenna test range (CATR)

Over-the-air testing was conducted with Rohde & Schwarz ATS800B compact antenna test range (CATR)

TX EVM Measurement

Opposite EVM Measurement(2 kits)

Measurements in the lab can be automated through MATLAB scripts for control of:

Learn more:

12) Terminology

Term Definition
mmW Millimeter wave frequency bands applicable to this project: 24.25 GHz – 40 GHz
mmWave Same as above.
BFIC Beamforming Integrated Circuit
FCIC Frequency Conversion Integrated Circuit
LO Local oscillator for up/down conversion between IF and RF TX/RX