Skip to content

Commit

Permalink
Revert "Makes TEG Circulator bidirectional" (Citadel-Station-13#6786)
Browse files Browse the repository at this point in the history
Reverts Citadel-Station-13#6764

It literally does not work as advertised. It doesn't work at all.
There's only one output side, it always puts into the output side. It
can take from the output side, and then it puts it back into the output
side. This is a non-functioning PR. Test your PRs properly.
  • Loading branch information
Putnam3145 authored Oct 6, 2024
1 parent 5e94691 commit 84d3bea
Show file tree
Hide file tree
Showing 2 changed files with 10 additions and 16 deletions.
Original file line number Diff line number Diff line change
Expand Up @@ -34,34 +34,28 @@

/obj/machinery/atmospherics/component/binary/circulator/Initialize(mapload)
. = ..()
desc = initial(desc) + " Its outlet port is to the [dir2text(dir)]."
air1.volume = 400
air2.volume = 400

/obj/machinery/atmospherics/component/binary/circulator/proc/return_transfer_air()
var/datum/gas_mixture/removed
if(anchored && !(machine_stat & BROKEN) && network1)
var/datum/gas_mixture/input_air
var/datum/gas_mixture/output_air
if(air1.return_pressure() > air2.return_pressure())
input_air = air1
output_air = air2
else
input_air = air2
output_air = air1
last_pressure_delta = max(input_air.return_pressure() - output_air.return_pressure() - 5, 0)
var/input_starting_pressure = air1.return_pressure()
var/output_starting_pressure = air2.return_pressure()
last_pressure_delta = max(input_starting_pressure - output_starting_pressure - 5, 0)

//only circulate air if there is a pressure difference (plus 5kPa kinetic, 10kPa static friction)
if(input_air.temperature > 0 && last_pressure_delta > 10)
if(air1.temperature > 0 && last_pressure_delta > 5)

//Calculate necessary moles to transfer using PV = nRT
recent_moles_transferred = (last_pressure_delta*network1.volume/(input_air.temperature * R_IDEAL_GAS_EQUATION))/3 //uses the volume of the whole network, not just itself
volume_capacity_used = min( (last_pressure_delta*network1.volume/3)/(input_air.return_pressure()*input_air.volume) , 1) //how much of the gas in the input air volume is consumed
recent_moles_transferred = (last_pressure_delta*network1.volume/(air1.temperature * R_IDEAL_GAS_EQUATION))/3 //uses the volume of the whole network, not just itself
volume_capacity_used = min( (last_pressure_delta*network1.volume/3)/(input_starting_pressure*air1.volume) , 1) //how much of the gas in the input air volume is consumed

//Calculate energy generated from kinetic turbine
stored_energy += 1/ADIABATIC_EXPONENT * min(last_pressure_delta * network1.volume , input_air.return_pressure()*input_air.volume) * (1 - volume_ratio**ADIABATIC_EXPONENT) * kinetic_efficiency
stored_energy += 1/ADIABATIC_EXPONENT * min(last_pressure_delta * network1.volume , input_starting_pressure*air1.volume) * (1 - volume_ratio**ADIABATIC_EXPONENT) * kinetic_efficiency

//Actually transfer the gas
removed = input_air.remove(recent_moles_transferred)
removed = air1.remove(recent_moles_transferred)
if(removed)
last_heat_capacity = removed.heat_capacity()
last_temperature = removed.temperature
Expand Down
2 changes: 1 addition & 1 deletion code/modules/power/generator.dm
Original file line number Diff line number Diff line change
Expand Up @@ -10,7 +10,7 @@ GLOBAL_LIST_EMPTY(all_turbines)
use_power = USE_POWER_IDLE
idle_power_usage = 100 //Watts, I hope. Just enough to do the computer and display things.

var/max_power = 5 MEGAWATTS
var/max_power = 500000
var/thermal_efficiency = 0.65

var/obj/machinery/atmospherics/component/binary/circulator/circ1
Expand Down