点击展开,查看详细教程!

SSH登录到pve后台,然后一条一条的执行命令

1.处理掉企业源

rm -rf /etc/apt/sources.list.d/pve-install-repo.list
echo "#deb https://enterprise.proxmox.com/debian/pve Bullseye pve-enterprise" > /etc/apt/sources.list.d/pve-enterprise.list

2.开始换源

wget https://mirrors.ustc.edu.cn/proxmox/debian/proxmox-release-bullseye.gpg -O /etc/apt/trusted.gpg.d/proxmox-release-bullseye.gpg
echo "deb https://mirrors.ustc.edu.cn/proxmox/debian/pve bullseye pve-no-subscription" > /etc/apt/sources.list.d/pve-no-subscription.list
echo "deb https://mirrors.ustc.edu.cn/proxmox/debian/ceph-pacific bullseye main" > /etc/apt/sources.list.d/ceph.list
sed -i.bak "s#http://download.proxmox.com/debian#https://mirrors.ustc.edu.cn/proxmox/debian#g" /usr/share/perl5/PVE/CLI/pveceph.pm
sed -i.bak "s#ftp.debian.org/debian#mirrors.aliyun.com/debian#g" /etc/apt/sources.list
sed -i "s#security.debian.org#mirrors.aliyun.com/debian-security#g" /etc/apt/sources.list
echo "deb http://download.proxmox.com/debian/pve bullseye pve-no-subscription" >>  /etc/apt/sources.list

3.最后更新

apt update && apt dist-upgrade -y

Proxmox VE 7.x 关订阅提示

点击展开,查看详细教程!

1.WinSCP登录到PVE,编辑打开这个文件:/usr/share/javascript/proxmox-widget-toolkit/proxmoxlib.js (防止手贱,建议备份)

2.搜索 data.status.toLowerCase,找到这一段:

jpg

3.直接删掉红框内容,变成如下图,最后保存即可。

jpg

  • 如果更新到PVE 7.1-5或者更新,发现改了上面的没效果,那么就要多改一步:

  • 继续搜索 data.status.toLowerCase,找到这一段:

jpg

  • 直接删掉红框内容,变成如下图,最后保存即可

jpg

4.改完保存,重进PVE界面刷新,去更新点击刷新,就没订阅提示了。


Proxmox VE 主界面显示CPU温度

点击展开,查看详细教程!

1.登录PVE的SSH,执行命令安装sensors:

apt-get install lm-sensors

2.探测下温度,执行:sensors-detect (一路yes,回车)

3.获取温度信息,执行:sensors

jpg

  • 红色箭头:temp1这里是主板温度,可能某些主板还有temp2、temp3等

  • 黄色箭头:Package id 0、core0~5这里是CPU温度,有多少个核心,就显示多少

4.WinSCP登录到PVE,修改这个文件:/usr/share/perl5/PVE/API2/Nodes.pm

(我习惯于下载到本地用Notepad++修改)

搜索:$res->{pveversion} = PVE::pvecfg::package()

在这个定义的下方添加:$res->{thermalstate} = `sensors`;

结果如图:

jpg

修改完保存,然后塞回路径。

5.修改这个文件:/usr/share/pve-manager/js/pvemanagerlib.js (建议备份,万一自己改炸就不好了。)

(我习惯于下载到本地用Notepad++修改)

搜索PVE Manager Version

jpg

  • 在这个定义的下方添加一个定义:
    {
          itemId: 'thermal',
          colspan: 2,
          printBar: false,
          title: gettext('温度'),
          textField: 'thermalstate',
          renderer:function(value){
              const p0 = value.match(/Package id 0.*?\+([\d\.]+)Â/)[1];
              const b0 = value.match(/temp1.*?\+([\d\.]+)?/)[1];
              return `CPU: ${p0} ℃ || 主板: ${b0} ℃ `
            }
    },

结果如图:

jpg

  • 上述是一种比较简单的万金油做法,有些人可能要把每个核心的温度有写出来,或者说有几个主板温度,也要一起写出来,那么就按照下列的格式:
    {
          itemId: 'thermal',
          colspan: 2,
          printBar: false,
          title: gettext('温度'),
          textField: 'thermalstate',
          renderer:function(value){
              const p0 = value.match(/Package id 0.*?\+([\d\.]+)Â/)[1];
              const c0 = value.match(/Core 0.*?\+([\d\.]+)Â/)[1];
              const c1 = value.match(/Core 1.*?\+([\d\.]+)Â/)[1];
              const c2 = value.match(/Core 2.*?\+([\d\.]+)Â/)[1];
              const c3 = value.match(/Core 3.*?\+([\d\.]+)Â/)[1];
              const c4 = value.match(/Core 4.*?\+([\d\.]+)Â/)[1];
              const c5 = value.match(/Core 5.*?\+([\d\.]+)Â/)[1];
              const b0 = value.match(/temp1.*?\+([\d\.]+)?/)[1];
              const b1 = value.match(/temp2.*?\+([\d\.]+)?/)[1];
              return `CPU: ${p0} ℃ || CPU1: ${c0} ℃ CPU2: ${c1} ℃ CPU3: ${c2} ℃ CPU4: ${c3} ℃ CPU5: ${c4} ℃ CPU6: ${c5} ℃ || 主板1: ${b0} ℃ 主板2: ${b1} ℃`
            }
    },

结果如图:

jpg

  • 红框内就是单独每个核心或者每个主板温度

  • 前面的CPU温度是综合温度,后面的CPU1~6是每个核心单独温度

  • 可根据实际情况增减CPU温度或者主板温度

  • 其实如果核心超过4个,不建议把每个核心温度写出来,不美观

6.改完执行 systemctl restart pveproxy 重进PVE主页,就看到温度显示了。

jpg


Proxmox VE 主界面显示(PCI-E盘位)硬盘温度

承接上一个显示CPU温度教程。

  • 此教程主要针对PCI-E盘位硬盘(也就是M.2固态),SATA盘位硬盘显示温度教程在下方。

  • 此教程是在上个“Proxmox VE 主界面显示CPU温度”基础上来做。

点击展开,查看详细教程!

* 扩展下,主界面添加M.2固态硬盘温度:

1.已经完成“Proxmox VE 主界面显示CPU温度”,然后终端执行:sensors

jpg

  • nvme-pci-0100此处就是M.2固态温度

2.修改这个文件:/usr/share/pve-manager/js/pvemanagerlib.js

在上个教程改CPU温度的定义里,加入下图红框内的内容:

const nvme0 = value.match(/Composite.*?\+([\d\.]+)Â/)[1];

|| 固态: ${nvme0} ℃

jpg

3.改完保存执行systemctl restart pveproxy重进PVE主页。

jpg


Proxmox VE 主界面显示CPU频率

承接上一个显示CPU温度教程。

点击展开,查看详细教程!

* 扩展下,主界面添加CPU频率:

1.也是修改 /usr/share/perl5/PVE/API2/Nodes.pm 和 /usr/share/pve-manager/js/pvemanagerlib.js 这2个文件

  • /usr/share/perl5/PVE/API2/Nodes.pm 刚刚修改CPU温度那里添加:
$res->{cpusensors} = `lscpu | grep MHz`;

jpg

  • /usr/share/pve-manager/js/pvemanagerlib.js 刚刚修改温度的下一行添加:
	{
          itemId: 'MHz',
          colspan: 2,
          printBar: false,
          title: gettext('CPU频率'),
          textField: 'cpusensors',
          renderer:function(value){
			  const f0 = value.match(/CPU MHz.*?([\d]+)/)[1];
			  const f1 = value.match(/CPU min MHz.*?([\d]+)/)[1];
			  const f2 = value.match(/CPU max MHz.*?([\d]+)/)[1];
			  return `实时: ${f0} MHz | 最小: ${f1} MHz | 最大: ${f2} MHz `
            }
	},

jpg

2.改完执行 systemctl restart pveproxy 重进PVE主页,效果如图:

jpg


Proxmox VE 主界面显示(SATA盘位)硬盘温度

同样承接上一个显示CPU温度教程。

  • 此教程主要针对SATA盘位硬盘。
点击展开,查看详细教程!

* 扩展下,主界面添加硬盘温度:

1.登录PVE的SSH,执行命令安装hddtemp:

apt-get install hddtemp
  • 然后执行 chmod +s /usr/sbin/hddtemp

  • 执行 hddtemp /dev/sd? 就能看到硬盘温度:

jpg

2.然后修改 /usr/share/perl5/PVE/API2/Nodes.pm 和 /usr/share/pve-manager/js/pvemanagerlib.js 这2个文件

  • /usr/share/perl5/PVE/API2/Nodes.pm 刚刚修改CPU温度那里添加:
 $res->{thermal_hdd} = `hddtemp /dev/sd?`;

jpg

  • /usr/share/pve-manager/js/pvemanagerlib.js 刚刚修改CPU温度的下一行添加:
	{
            itemId: 'thermal-hdd',
            colspan: 2,
            printBar: false,
            title: gettext('硬盘温度'),
            textField: 'thermal_hdd',
            renderer: function(value) {
                value = value.replaceAll('Â', '');
                return value.replaceAll('\n', '<br>');
            }
	},

jpg

3.改完执行 systemctl restart pveproxy 重进PVE主页,效果如图:

jpg


Proxmox VE 改显示范围

如果发现改上面的温度/CPU频率/硬盘温度,步骤又没错,但是主界面不显示,就需要下列教程。

点击展开,查看详细教程!

改布局:

  • 还是这个文件:pvemanagerlib.js,搜索:widget.pveNodeStatus

jpg

将 height: 300 改大为400,或者更大,然后保存。

  • 搜索:gettext('Status') + ': ' + zpool (这一处不一定有,搜不到,就不用管了。)

jpg

将 height: 600 改大为700,或者更大,然后保存。


核显直通(intel)

点击展开,查看详细教程!

1.编辑GRUB配置文件:/etc/default/grub

sed -i "s/quiet/quiet intel_iommu=on iommu=pt video=efifb:off,vesafb:off/g" /etc/default/grub

改好结果:

jpg

然后执行:

update-grub

2.添加所需的系统模块(驱动):/etc/modules

echo "vfio" >> /etc/modules

echo "vfio_iommu_type1" >> /etc/modules

echo "vfio_pci" >> /etc/modules

echo "vfio_virqfd" >> /etc/modules

改好结果:

jpg

  • PVE7.x 直接跳过3、4、5,直接到第6步即可;PVE6.x就一步步看。

3.添加模块(驱动)黑名单:/etc/modprobe.d/pve-blacklist.conf

echo "blacklist snd_hda_intel" >> /etc/modprobe.d/pve-blacklist.conf

echo "blacklist snd_hda_codec_hdmi" >> /etc/modprobe.d/pve-blacklist.conf

echo "blacklist i915" >> /etc/modprobe.d/pve-blacklist.conf

改好结果:

jpg

4.查看GPU的ID:

lspci -nn | grep VGA

比如我的:

00:02.0 VGA compatible controller [0300]: Intel Corporation HD Graphics [8086:1606] (rev 08)

jpg

  • 8086:1606 就是核显的ID

  • 00:02.0 是核显的编号

接着执行:(ids=xxxx:xxxx,xxxx:xxxx替换成你获取的ID)

echo "options vfio-pci ids=8086:1606" >> /etc/modprobe.d/vfio.conf

5.如果要音频直通,就搜索音频设备的ID

lspci -nn | grep Audio

比如我的:

00:03.0 Audio device [0403]: Intel Corporation Broadwell-U Audio Controller [8086:160c] (rev 08)
00:1b.0 Audio device [0403]: Intel Corporation Wildcat Point-LP High Definition Audio Controller [8086:9ca0] (rev 03)

jpg

  • 8086:160c/8086:9ca0 就是音频设备ID (一个是板载,一个是单独的音频孔,所以是2个)

  • 00:03.0/00:1b.0 是音频设备编号

接着执行:(ids=xxxx:xxxx,xxxx:xxxx替换成你获取的GPU/音频设备ID,用英文逗号隔开)

echo "options vfio-pci ids=8086:1606,8086:160c,8086:9ca0" >> /etc/modprobe.d/vfio.conf

6.更新内核并重启:

执行:

update-initramfs -u

reboot

7.验证是否开启iommu:

终端输入:

dmesg | grep 'remapping'

要出现:DMAR-IR: Enabled IRQ remapping in x2apic mode

接着用下面的命令:

find /sys/kernel/iommu_groups/ -type l  

出现很多数据,每一行最后的xx:xx.x是设备编号,查看要直通的设备的编号是否在里面。

8.添加PCI设备即可:(我只添加核显,音频设备看设备编号按需添加)

jpg

jpg

9.验证核显直通成功没?

  • 在直通后的系统的终端执行:
ls /dev/dri
  • 输出如图,出现“renderD128”就成功了:

jpg


黑群晖7.x人脸识别(DS918+)

点击展开,查看详细教程!

1.已经按照上面的步骤,核显直通黑裙7;

2.编辑"/etc/pve/qemu-server/102.conf"文件:

  • 为啥是102.conf,因为演示的黑裙7的虚拟机ID是102,根据你自己的来。

显卡hostpci0: 这一行的最后,添加:

,legacy-igd=1

jpg

3.回到PVE管理界面,更改黑裙7的硬件——显示为无,然后重启黑裙7。

jpg

4.然后等待Photos索引,就能看到人脸已经识别了。

jpg


GVT-G直通(intel)

此方式适合桌面级别的U(差不多5代起步),小主机(J4125/N5105等)不支持!!!

  • 这种直通和上面的直通方法,二选一,不能同时选2种!!!

  • 好处是显卡拆成好多个分别给不同虚拟机使用。

点击展开,查看详细教程!

1.首先在主板BIOS里面启用GTD,GTX等选项,若有aperture size选项,建议512M,没有就不管吧;

2.编辑GRUB配置文件:/etc/default/grub

sed -i "s/quiet/quiet intel_iommu=on i915.enable_gvt=1/g" /etc/default/grub

然后执行:

update-grub

3.添加所需的系统模块(驱动):/etc/modules

echo "vfio" >> /etc/modules

echo "vfio_iommu_type1" >> /etc/modules

echo "vfio_pci" >> /etc/modules

echo "vfio_virqfd" >> /etc/modules

echo "kvmgt" >> /etc/modules

4.更新内核并重启:

执行:

update-initramfs -u

reboot

5.验证是否开启GVT:

0000:00:02.0 将00:02.0换成自己的GPU的编号 (lspci -nn | grep VGA 查看,最前面的就是)

ls /sys/bus/pci/devices/0000:00:02.0/mdev_supported_types/

出现如下即为成功(教程机核显为UHD630):

i915-GVTg_V5_4 i915-GVTg_V5_8

6.配置直通:

cpu类型设置成HOST,将机器设置成q35,将虚拟机显卡设置成无,添加PCIE设备:勾选高级里的ROM-Bar和PCI-E,主GPU不勾选,MDev类型选择合适"显卡"。

jpg

  • “可用”显示的多少,就可以添加多个“显卡”。

比如上图就是说:只能添加1个v5_4的“显卡”或者添加2个v5_8的“显卡”,只能用一种类型的显卡。


GVT-G改显存,增加"显卡"

承接上一个GVT-G直通教程。

此教程有风险,请知悉,若操作,请自行承担风险。

点击展开,查看详细教程!

为了分配更多显卡,需给核显分配更多显存。但一般主板的BIOS并没有给调节显存的选项"aperture size",只给了类似DVMT(共享显存)选项,最大1024MB,当把DVMT改成1024MB后,并没有用。所以本教程强行改aperture size。

通过命令 lspci -vs 00:02.0 查看,一般默认是256M。

jpg

128M的显卡只有一个,所以需要改大到512M。

jpg

1.自行去主板官网下载当前主板的BIOS(注意版本),然后下载教程提供的工具包。

工具包下载地址

2.使用工具包里的UEFITool0270工具,打开BIOS文件,提取模块;

jpg

  • 按Ctrl+F打开搜索页面,切换到text选项卡,搜索aperture size:

jpg

  • 点击搜索出来的结果,会跳转到对应模块位置;

jpg

  • 然后导出模块,并另存为。

jpg

jpg

3.使用工具包里的IRFExtractor.exe打开另存为的文件,找偏移量。

  • 打开,并解析出文本,另存为。

jpg

jpg

  • 打开解析文本,搜索aperture size,红框内的 0x2E8 就是我们要找的偏移量。每个主板的BIOS偏移量不一样。

jpg

  • 通过图可以看出,默认是0x1,也就是256M。若要改512M,就得默认0x3,改1G,就得默认0x7。

jpg

4.准备一个U盘,格式化为FAT32,然后把工具包内的EFI文件夹放U盘根目录,然后电脑重启进U盘引导。

jpg

  • U盘引导进入grub命令行模式,直接输入命令:setup_var 0x2E8 0x3 ,意思就是把aperture size的偏移量默认改成0x3,也就是aperture size为512M。

  • 建议只改512M,经验告诉我们改1G,可能会出问题。

jpg

5.改完成功后,开机PVE,就会看到"显卡"多了很多。

通过命令 lspci -vs 00:02.0 查看,已经变成512M。

jpg

jpg


GVT-G黑群辉核显直通+人脸

点击展开,查看详细教程!

1.先把群辉虚拟机关机,然后硬件——显示,设为无; 然后修改虚拟机配置文件;

/etc/pve/qemu-server/102.conf (教程演示群辉虚拟机ID是102,所以是102.conf)

在配置文件第一行写入以下代码:

args: -device vfio-pci,sysfsdev=/sys/bus/mdev/devices/604e42e4-2e90-11ec-8861-037c58d42915,addr=02.0,x-igd-opregion=on,driver=vfio-pci-nohotplug

jpg

2.然后PVE终端,运行命令:

mkdir /var/lib/vz/snippets

cp /usr/share/pve-docs/examples/guest-example-hookscript.pl /var/lib/vz/snippets/102-autocreate.pl

尾部的102和虚拟机ID对应;然后修改/var/lib/vz/snippets/102-autocreate.pl,在如图位置添加下列2行代码:

system("echo 604e42e4-2e90-11ec-8861-037c58d42915 > /sys/bus/pci/devices/0000:00:02.0/mdev_supported_types/i915-GVTg_V5_4/create");

上一行代码中的i915-GVTg_V5_4,取决于你要什么类型的显卡,V5_2/8都行。


system("echo 1 > /sys/bus/mdev/devices/604e42e4-2e90-11ec-8861-037c58d42915/remove");

jpg

3.最后终端执行:qm set 102 --hookscript local:snippets/102-autocreate.pl (102和虚拟机ID对应)

4.群辉开机,核显已经直通,且photo人脸ok。


直通硬盘(全盘映射)

点击展开,查看详细教程!

上面说了核显直通,接着说硬盘直通。前面步骤完成了,现在很简单了。

1.查看读取存储设备序列号:

ls /dev/disk/by-id

jpg

找出自己的硬盘序列号。比如我的就是:

ata-ST1000XXXXXXXXXXXXXXX

2.执行命令:

  • 102:改成自己要直通硬盘的的虚拟机ID。

  • sata1:已有sata0,所以往后排,为sata1,按需修改。

qm set 102 -sata1 /dev/disk/by-id/ata-ST1000XXXXXXXXXXXXXXX

返回下面信息就说明成功挂载:

update VM 102: -sata1 /dev/disk/by-id/ata-ST1000XXXXXXXXXXXXXXX

3.返回PVE查看,已经挂载,重启即可完成。

jpg


PVE 直接安装Docker

点击展开,查看详细教程!

1.登录PVE的SSH,输入以下命令,安装Docker:

curl -sSL https://get.docker.com/ | sh

chmod 777 /var/run/docker.sock

systemctl start docker

systemctl enable docker.service

上面的命令一条一条执行完毕后,docker就安装好了。

jpg

2.接着终端继续输入命令,安装Portainer-CE汉化版:

docker run -d --restart=always --name="portainer" -p 9000:9000 -v /var/run/docker.sock:/var/run/docker.sock -v portainer_data:/data 6053537/portainer-ce

3.等待上述安装命令执行完毕,然后打开PVE的IP地址+9000端口,进入Portainer-CE。

ps:例如我的pve的ip是192.168.100.1,那么就是进入http://192.168.100.1:9000。

jpg


PVE r8125b多队列支持

点击展开,查看详细教程!

1.首先在帖子里下载编译好的驱动,然后解压:

下载驱动

jpg

jpg

2.将解压出来的deb格式的驱动放到pve系统的root目录下,然后终端执行:

jpg

  • 依次执行下列命令:(一次一行)
apt install ethtool

apt update && apt install pve-headers-$(uname -r)

apt install dkms

dpkg -i realtek-r8125-dkms_9.009.00-1_amd64.deb

echo 'blacklist r8169' >> /etc/modprobe.d/blacklist-r8169.conf
  • 继续终端执行:uname -r或者当前pve系统的内核版本,并复制下来:

jpg

  • 然后执行:update-initramfs -u -k 内核版本

  • 比如教程演示机的pve内核版本为:5.15.35-1-pve,那么执行的命令就是:update-initramfs -u -k 5.15.35-1-pve

jpg

  • 上述命令都执行完成后重启

3.重启pve后,进入pve控制台,查找r8125b网卡的名称;

每个人的机器,显示的名称的不一样,自己的网卡具体是啥名称,自行判断!

jpg

4.然后终端执行:ethtool -i enp4s0 (请将enp4s0换成你自己的网卡名称),可以看到r8125b的驱动已经替换成功。

jpg

5.最后终端执行 grep -E enp* /proc/interrupts 就可以看到是多个队列了。