- Supports target temperature
- Supports operating modes
Set the temperature step of water heater (1 by default).
{ "temperature_step": 0.5 }
EntityID | Class | Description |
---|---|---|
water_heater.{DEVICEID}_water_heater | water_heater | Water heater entity |
EntityID | Class | Description |
---|---|---|
sensor.{DEVICEID}_compressor_temperature | sensor | Compressor Temperature |
sensor.{DEVICEID}_condenser_temperature | sensor | Condenser Temperature |
sensor.{DEVICEID}_outdoor_temperature | sensor | Outdoor Temperature |
binary_sensor.{DEVICEID}_compressor_status | binary_sensor | Compressor Status (It may doesn't work in some devices) |
switch.{DEVICEID}_power | switch | Power |
Set the attribute of appliance. Service data:
Name | Description |
---|---|
device_id | The Appliance code (Device ID) of appliance |
attribute | "power" |
value | true or false |
Example
service: midea_ac_lan.set_attribute
data:
device_id: XXXXXXXXXXXX
attribute: power
value: false