Class=110 (0x6E) - IR Remote I/f

CLASS1.IR

Description

This is the IR code sent/received from common remote controls.

Type=0 (0x00) - General event {#type0}

VSCP_TYPE_REMOTE_GENERAL

General Event.

Type=1 (0x01) - RC5 Send/Receive {#type1}

VSCP_TYPE_REMOTE_RC5

A RC5 remote code. [http://www.xs4all.nl/~sbp/knowledge/ir/sirc.htm ]Use the VSCP abstract remote format if possible.

Byte Description
0 RC5 code.
1 RC5 Address.
2 Repeat count if any.

Type=3 (0x03) - SONY 12-bit Send/Receive {#type3}

VSCP_TYPE_REMOTE_SONY12

A SONY remote code. [http://www.xs4all.nl/~sbp/knowledge/ir/sirc.htm] Use the VSCP abstract remote format if possible.

Byte Description
0 SONY code.
1 SONY address.
2 Repeat count if any.

Type=32 (0x20) - LIRC (Linux Infrared Remote Control) {#type32}

VSCP_TYPE_REMOTE_LIRC

Packed LIRC codes code. LRC Codes are normally sent as 64-bit codes or even larger codes. Only codes with a length less then 56 bits (7-bytes) are supported by VSCP and the most significant byte of the LIRC code is not transferred. http://www.lirc.org/

Byte Description
0 LIRC Code, MSB.
1 LIRC Code.
2 LIRC Code.
3 LIRC Code.
4 LIRC Code.
5 LIRC Code.
6 LIRC Code. LSB.
7 Repeat count if any.

Type=48 (0x30) - VSCP Abstract Remote Format {#type48}

VSCP_TYPE_REMOTE_VSCP

Instead of sending codes that relates to a certain remote this format is general. And therefore more flexible

Byte Description
0 Code, MSB.
1 Code LSB.
2 Zone for which event applies to (0-255). 255 is all zones.
3 Sub-zone for which the event applies to (0-255). 255 is all sub-zones.
4 Repeat count if any.

Type=49 (0x31) - MAPito Remote Format {#type49}

VSCP_TYPE_REMOTE_MAPITO

Instead of sending codes that relates to a certain remote this format is general. And therefore more flexible.

Byte Description
0 Repeat Count.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which the event applies to (0-255). 255 is all sub-zones.
3 Control address MSB.
4 Control address.
5 Control address.
6 Control address LSB.
7 Key Code.