Notifications
You must be signed in to change notification settings - Fork 5
/
testscript.vbs
130 lines (122 loc) · 4.32 KB
/
testscript.vbs
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
' This program illustrates the use of a simple script to control the RoboFocus
' switches to control the automation. Program assumes that the RF application has
' not been opened yet.
' Program Flow
' Starts Instruments
' Open Dome
' Note:
' ********************************************************************************
'Global Objects
Dim ar 'ascom Remote 1
Dim u 'Requires ASCOM development platform - helper class
' ********************************************************************************
'Global variables
Dim Startup
' ********************************************************************************
' *
' * Main Program Flow
' *
Call Welcome
Call createObjects
Call connectObjects
Call testDriverinfo
Call testActions
Call testMethods
Call disconnectObjects
Call disposeObjects
wscript.echo "Startup Successful at", Time
WScript.Quit
' ********************************************************************************
' *
' * Subroutines
' *
'********************************************************************************
Sub Welcome()
Startup = MsgBox ("Initialize ASCOM switch testing", 4, "Confirm test")
' Startup contains either 6 or 7, depending on which button is clicked.
If Startup = 7 then WScript.Quit
WScript.Echo "Push OK to begin Startup"
End Sub
'********************************************************************************
function OpenPrgs( progname )
Set oWmi = GetObject("winmgmts:" & " {impersonationLevel=impersonate }! " & "." & " root cimv2")
TimeEnd = Timer + 2
Do While Timer < TimeEnd
Loop
query = "Select * from Win32_Process Where Name = '"
query = query + progname
query = query + "'"
Set colProcessList = oWmi.ExecQuery(query)
if colProcessList.count = 0 then
Set WshShell = CreateObject("WScript.Shell")
set oExec = WshShell.Exec("C: Program Files Common Files ASCOM Focuser RoboFocus.exe")
TimeEnd = Timer + 10
Do While Timer < TimeEnd
Loop
end if
End func
'********************************************************************************
Sub createObjects()
Set ar = WScript.CreateObject("ASCOM.Remote1.Switch")
' Set u = CreateObject("DriverHelper.Util")
End Sub
'********************************************************************************
Sub connectObjects()
ar.connected = true
If ar.connected Then
wscript.echo "ASCOM remote switch connected."
else
wscript.echo "ASCOM remote switch failed to connect."
WScript.Quit
End If
End Sub
'********************************************************************************
Sub disconnectObjects()
ar.connected = false
If ar.connected Then
wscript.echo "ASCOM remote switch failed to disconnect."
End If
End Sub
'********************************************************************************
Sub disposeObjects()
set ar = Nothing
Set u = Nothing
End Sub
'********************************************************************************
Sub testMethods()
Dim i = 0
for i=0, ar.MaxSwitch step 1
if ar.CanWrite( i ) then
wscript.echo "Switch component " & i & ar.getSwitchDescription( i )
wscript.echo "Switch name " & i & ar.getSwitchName( i )
wscript.echo "Switch component " & i & ar.getSwitchDescription( i )
wscript.echo "Switch step size " & i & ar.SwitchStep( i )
if ar.switchStep = 1.0 then
ar.setSwitch( i, true )
delay(1000)
ar.setSwitch( i, false )
delay(1000)
else
wscript.echo "Non-boolean switch found - can't toggle: " & i
end if
end if
next
End Sub
'********************************************************************************
Sub testDriverInfo()
' Check all the basic driver information first
if ar.Connected = false then
ar.Connected = true
wscript.echo "Driver name is " & ar.Name
wscript.echo "Driver version is " & ar.DriverVersion
wscript.echo "API interface version is" & ar.InterfaceVersion
wscript.echo "Driver Info is ", ar.DriverInfo
wscript.echo "Driver supported actions are: " & ar.SupportActions
wscript.echo "Switch component count is: " & ar.MaxSwitch
End Sub
'********************************************************************************
Sub testActions()
' Check all the basic driver information first
if ar.Connected = false then
ar.Connected = true
End Sub