import os
import pytest
import tempfile
from tools.driver import Driver, DRV_TYPE_DIAG
from tools.mbuper import download_mbu, MbuWrapper
from infra.test_base import TestBase, idparametrize
from tools.constants import LINK_SPEED_100M, LINK_SPEED_2_5G, \
LINK_SPEED_5G, LINK_SPEED_10G
from tools.utils import get_atf_logger
from tools.lom import LightsOutManagement
log = get_atf_logger()
def setup_module(module):
# import tools._test_setup # uncomment for manual test setup
os.environ["TEST"] = "ptp_avb"
class TestPtpAvb(TestBase):
mbu_wrapper = None
@classmethod
def setup_class(cls):
super(TestPtpAvb, cls).setup_class()
try:
cls.log_server_dir = cls.create_logs_dir_on_log_server()
cls.install_firmwares()
cls.dut_driver = Driver(port=cls.dut_port, drv_type=DRV_TYPE_DIAG, version=cls.dut_drv_version)
cls.dut_driver.install()
cls.mbu_dir = download_mbu(cls.mbu_version, cls.working_dir)
log.info("Initializing MBU wrapper")
cls.mbu_wrapper = MbuWrapper(mbu_dir=cls.mbu_dir, port=cls.dut_port)
cls.log_local_dir = os.path.join(cls.mbu_dir, "logs")
except Exception as e:
log.exception("Failed while setting up class")
raise e
def setup_method(self, method):
super(TestPtpAvb, self).setup_method(method)
if os.environ.get("LOM_TEST", None):
self.LOM_ctrl = LightsOutManagement(host=self.dut_hostname, port=self.dut_port)
self.LOM_ctrl.set_lom_mac_address(self.LOM_ctrl.LOM_MAC_ADDRESS)
self.LOM_ctrl.LoM_enable()
self.LOM_ctrl.set_lom_ip_address(self.LOM_ctrl.LOM_IP_ADDRESS)
def teardown_method(self, method):
super(TestPtpAvb, self).setup_method(method)
if os.environ.get("LOM_TEST", None):
self.LOM_ctrl.LoM_disable()
@idparametrize("t", ["ptp_sync", "ptp_delay_req"])
@idparametrize("c", [2, 4])
@idparametrize("s", [LINK_SPEED_100M, LINK_SPEED_2_5G, LINK_SPEED_5G, LINK_SPEED_10G])
@idparametrize("en", ["before_link_up", "after_link_up"])
def test_loopb(self, t, c, s, en):
pkt_type = t
pkt_count = c
speed = s
when_enable = en
scripts_path = os.path.join(os.environ["ATF_HOME"],
"qa-tests/tools/beton")
self.mbu_wrapper.set_var("PWD", scripts_path)
self.mbu_wrapper.set_var("pkt_type", pkt_type)
self.mbu_wrapper.set_var("pkt_count", pkt_count)
self.mbu_wrapper.set_var("link_speed", speed)
self.mbu_wrapper.set_var("when_enable_ptp", when_enable)
self.mbu_wrapper.exec_txt("PTP/ptp_2side.txt")
report = self.mbu_wrapper.get_var("finalReport")
if len(report) != 0:
raise Exception("MBU script detected error")
if __name__ == "__main__":