Advanced operation

There are a number of settings and commands that are available via MQTT. To use these you must have set up the device to connect to an MQTT server. You then need a means to send messages to the MQTT server for the device.

The hostname you picked is used for these messages. The format for commands and settings is defined in RevK library. But is basically quite simple. We'll use GuestAC as the example hostname.

Type Format Meaning
Command command/GuestAC/command This issues commands to the device to do something now.
Setting setting/GuestAC This allows settings to be set. The payload is JSON, with one or more settings. e.g. setting/GuestAC {"fanstep":2,"reporting":60}. With no payload the existing settings are returned in the same format.
Setting (direct) setting/GuestAC/thing This allows a single setting to be set, the payload is the value, e.g. setting/GuestAC/debug 1
State state/GuestAC/whatever Status messages - these are normally retained and relate to specific aspects of the operation. With no paramater, e.g. state/GuestAC this is the state of the device itself, with false meaning it is now offline.
Event event/GuestAC/whatever Event messages are one of things that have happened and are not retained.
Info info/GuestAC/whatever Info messages are informational, and don't relate to a specific event happening.
Error error/GuestAC/whatever Errors are reported using this.

Faikin auto

The Faikin auto logic allows a set point (with a margin) and a reference to external temperature. It uses simple prediction to see if we are going to exceed the maximum or minimum or be within range (see below), and aims to stay in range by basically turning the aircon just on or off. It does the on or off by changing the set point given to the air con to be higher or lower, in simplest terms.

However there are a few settings to control what on and off mean in this case. the simplest, default, is much higher than current temperature or much lower than current temperature, i.e. around ±6℃.

The actual set point logic set a set point, and adds heatover or subtracts heatback adjustment for heating or subtracts coolover or adds coolback for cooling. The basis for these is one of there options.

  1. The default (temptrack off, tempadjust on) is your requested set point, adjusted for the air con temperature not matching your external temperature.
  2. Non adjusted (temptrack off, tempadjust off) just uses the set point you have asked for as a basis.
  3. Tracking (temptrack on) uses what the air con sees as the current temperature, allowing you to constantly nudge the aircon towards the target you want

There is also a setting hold off adjustments (e.g. when tracking) for a time period (tempnoflap).

Staying in range

The auto mode has a target range, a min and max. On the web page this is set by a target and tolerance, so if you set 21℃ with ±1℃ that is a range of 20℃ to 22℃. This is the comfort zone, the range in which you would like the temperature to stay.

To achieve this the Faikin looks at the temperature and sets the heating/cooling on or off as explained above. When heating, it is basically looking to keep the temperature just above min, and for cooling just below max. Note, it it not aiming for the middle, just to be within the range.

When looking at the current temperature it looks ahead, as the aircon has some inertia, it samples every tpredicts seconds and looks ahead tpredictt periods. This allows it to act before the temperature goes too far one way or the other.

I simplest terms, if heating, if the temperature will be above min it turns off, and if it will be below min it turns on. However, that would simply mean a temperature hovering around min. To aim for somewhere between min and max it actually adjusts its target, increasing min by pushtemp (default 0.1℃) so it hovers a bit above min. For cooling this works the other way around and relates to max.

The temperature band is also used to work out if we need to reverse heating/cooling. This is where max comes in for heating (min for cooling). If we are heating but spending all the time over max we switch to cooling. If we are always within min to max it will turn off. Bear in mind this is based on predicted temperature, so we may be within min to max because the heating is turned on/off to keep us there, and that does not turn off as the predicted temp will have gone out of range. There is an adjustment to the switching temperature, e.g. in heating max is adjusted by switchtemp.

Thermostat mode

You can set the thermostat - this changes the target we use. When not in this mode, heating aims for min and cooling aims for max. In thermostat mode heating aims for max until it gets there, and then lets things cool to min before turning back on again, adding hysteresis.

Thermostat mode also disables the pushtemp/switchtemp adjustment, and makes the default set point reference min or max depending on the current heating mode and hysteresis.

Settings

There are a number of standard settings as per the RevK library, including things like hostname, mqtthost, wifissid, etc. Settings specific to the Faikin module are as follows.

The web pages provide settings for the basic WiFi/MQTT, the Faikin specific settings, and an Advanced settings page listing a lot of more detailed settings.

Note that web settings can be disabled with websettings, and the web based control pages can be disabled with webcontrol. It is also possible to apply a password for the web settings 9this is not sent security, so use with care on a local network which you control).

Automatic on/off

Every tsample seconds the relationship of the adjusted min, max and current are assessed to consider how much time was approaching the target band, in the target band, or beyond the target band. Two whole samples in a row are considered. Sampling is reset on change of power or mode.

If auto1 is set, the power on at start of that minute. If auto0 is set, the power off at start of that minute.

If autop is set, and the last sample period is entirely outside the target band, and the current temperature is more than autoptemp degrees above or below the target band, then automatic power on.

If autop is set, and the last two sample periods are entirely inside the target band, then automatic power off.

Remote

The system is designed to work with an external remote Environmental monitor. This sends a command control periodically containing JSON with env being current temperature, and target being an array of min and max target temperature. When remote working autop is assumed if autoptemp is not 0.

Special settings

Some more advances settings which you are unlikely to need to ever change.

Setting Meaning
debug true means output lots of debug - notable for S21 this is one line with a set of poll responses. This also causes more fields to be polled than normal, so slower response times.
dump true means output raw serial communications
uart Which internal UART to use
tx Which GPIO for tx, prefix - to invert the port
rx Which GPIO for rx, prefix - to invert the port

Commands

Command Meaning
on off Power on/off
heat cool auto fan dry Change mode
low medium high Change fan speed
temp Set target temp (argument is temp)
status Force a status report to be sent
control JSON payload with aircon controls, see below
send Force sending S21 message, e.g. D62000, can be a JSON string, or a JSON array of strings to be sent. Use \u0080 to \u00FF for high bit bytes

Status

Regular status messages are sent.

  • state/ topic indicate current state, and are reported periodically and on some state changes.
  • Faikin/ topic are sent, typically every minute, and intended for the faikinlog command to store in a database.
  • *MAC*/ topic are sent for HomeAssistant if enabled, and are reported periodically and on some state changes.

The setting livestatus causes the state/ topic on any change.

Attribute Meaning
online Boolean, if the aircon is connected and online
heat Boolean, if in heating mode
slave Boolean, set if we are not master for heat/cool and hence cannot do requested mode
antifreeze Boolean, set if in antifreeze mode and hence not operating as normal
model Model name, if known
home Temperature at remote / measured
outside Outside temperature, if known
inlet Inlet temperature, if known
liquid Liquid coolant feed temperature, if known
control Boolean, if we are under external/automatic control

The faikinglog reports the last periods for values. For each value, if it is the same for the whole period it is reported as is. If not, then for numeric is reported as an array of min, ave, max. For an enumerated type it is the current value. For a Boolean, it is a value 0.0 to 1.0 indicating how much it was true in the period.

The fixstatus setting forces the format as if the value had changed during the period, i.e. min/ave/max array or 0.0-1.0 for Boolean.

Aircon control

The controls are things you can change. These can be sent in a JSON payload in an MQTT control command (with no suffix), and are reported in the status MQTT JSON.

Attribute Meaning
power Boolean, if aircon powered on
mode One of H (Heat), C (Cool), A (Auto), D (Dry), F (Fan)
temp Temperature, in Celcius
fan One of A (Auto), Q (Night) and 1 to 5 for manual fan levels
swingh Boolean - horizontal louvre swing
swingv Boolean - vertical louvre swing
powerful Boolean
econo Boolean
autor Range for automation, 0.0 means off - this sets the autor setting to 10 times this value
autot Target temp for automation, This sets the autot setting to 10 times this value
autob The name of the BLE device. This sets the autob setting
auto0 Time to turn off HH:MM, 00:00 is don't turn off. This sets the auto0 setting
auto1 Time to turn off HH:MM, 00:00 is don't turn on. This sets the auto1 setting
target This can be a single temperature, or an array of two temperatures (min/max) which forces Faikin auto mode
env This is the temperature reference used for the Faikin auto mode
streamer Boolean

For remote controlled Faikin auto mode, you typically send a control message with target and env in the JSON payload. This needs to be sent regularly to avoid it revertign to normal (not Faikin auto mode).

Debug

All of the protocols are reverese engineered, and some times now things come to light and new models.

The snoop and dump and debug settings can help decode what is happening.

For anyone in the UK trying to reverse engineer operations using an offical remote / control, we have a small number of dual port pass through modules to assist with debug.