Skip to content

Commit

Permalink
Merge pull request #22 from elad-bar/refactor-entities
Browse files Browse the repository at this point in the history
Refactor entities
  • Loading branch information
elad-bar authored May 26, 2023
2 parents 2a323f9 + 9694356 commit d1e4bb0
Show file tree
Hide file tree
Showing 17 changed files with 1,433 additions and 523 deletions.
40 changes: 40 additions & 0 deletions .github/ISSUE_TEMPLATE/bug_report.md
Original file line number Diff line number Diff line change
@@ -0,0 +1,40 @@
---
name: Bug report
about: Create a report to help us improve
title: ""
labels: ""
assignees: ""
---

**Describe the bug**
A clear and concise description of what the bug is.

**To Reproduce**
Steps to reproduce the behavior:

1. Go to '...'
2. Click on '....'
3. Scroll down to '....'
4. See error

**Expected behavior**
A clear and concise description of what you expected to happen.

**Screenshots**
If applicable, add screenshots to help explain your problem.

**Desktop (please complete the following information):**

- OS: [e.g. iOS]
- Browser [e.g. chrome, safari]
- Version [e.g. 22]

**Smartphone (please complete the following information):**

- Device: [e.g. iPhone6]
- OS: [e.g. iOS8.1]
- Browser [e.g. stock browser, safari]
- Version [e.g. 22]

**Additional context**
Add any other context about the problem here.
19 changes: 19 additions & 0 deletions .github/ISSUE_TEMPLATE/feature_request.md
Original file line number Diff line number Diff line change
@@ -0,0 +1,19 @@
---
name: Feature request
about: Suggest an idea for this project
title: ""
labels: ""
assignees: ""
---

**Is your feature request related to a problem? Please describe.**
A clear and concise description of what the problem is. Ex. I'm always frustrated when [...]

**Describe the solution you'd like**
A clear and concise description of what you want to happen.

**Describe alternatives you've considered**
A clear and concise description of any alternative solutions or features you've considered.

**Additional context**
Add any other context or screenshots about the feature request here.
8 changes: 8 additions & 0 deletions CHANGELOG.md
Original file line number Diff line number Diff line change
@@ -1,5 +1,13 @@
# Changelog

## v3.0.1

- Refactor entity's creation (using EntityDescription)
- Mapped all protocol codes to `EntityDescription`
- Add more entities (updated list in README)
- Create [Protocol Codes](https://github.com/radical-squared/aquatemp/blob/master/PROTOCOL_CODES.md) document
- Fix `climate` HVAC Modes

## v3.0.0

- Major refactor to the code - Breaking changes
Expand Down
243 changes: 243 additions & 0 deletions PROTOCOL_CODES.md
Original file line number Diff line number Diff line change
@@ -0,0 +1,243 @@
# Protocol Codes

## Control parameters

| Parameter | Description |
| ----------- | --------------- |
| Power | Power |
| Mode | HVAC Mode |
| Manual-mute | Fan Mode |
| 2074 | 2074 |
| 2075 | 2075 |
| 2076 | 2076 |
| 2077 | 2077 |
| Set_Temp | Set Temperature |
| 1158 | 1158 |
| 1159 | 1159 |

## Hardware parameter

| Parameter | Description |
| --------- | ---------------------------------------------------- |
| /01 | Whether enable system 1 high pressure switch |
| /02 | Whether enable system 2 high pressure switch |
| /03 | Whether enable system 1 low pressure switch |
| /04 | Whether enable system 2 low pressure switch |
| /05 | Whether enable phase monitor protection |
| /06 | Whether enable water flow protection |
| /07 | Whether enable electrical heater Overload protection |
| /08 | Whether enable system 1 overload protection |
| /09 | Whether enable system 2 overload protection |
| /10 | Whether enable remote on/off switch |
| /11 | Whether enable system protect |
| /12 | Whether enable Outlet probe |
| /13 | Whether enable Coil 1 probe |
| /14 | Whether enable Coil 2 probe |
| /15 | Whether enable Ambient probe |
| /16 | Whether enable deice 1 probe |
| /17 | Whether enable deice 2 probe |
| /18 | Whether enable Suction 1 probe |
| /19 | Whether enable Suction 2 probe |
| /20 | Whether enable exhaust 1 probe |
| /21 | Whether enable exhaust 2 probe |
| /22 | Whether enable ΔT1 protect |
| /23 | Whether enable Cooling mode |
| /24 | Whether enable Economic heating |
| /25 | Whether enable AUTO mode |
| /26 | Whether enable Heating mode |
| /27 | Whether enable High demand |
| /28 | Whether enable heat recovery temperature |

## Protection parameter

| Parameter | Description |
| --------- | ----------------------------------------------- |
| A01 | High pressure alarm time delay |
| A02 | Low pressure alarm time delay |
| A03 | Stop unit air temperature |
| A04 | Antifreeze setting temperature |
| A05 | Antifreeze differential protection |
| A06 | Discharge temp. protection setting |
| A07 | Discharge temp. differential protection |
| A08 | Inlet/Out differential protection setting value |
| A09 | Start spraying air temperature |

## Compressor parameter

| Parameter | Description |
| --------- | ----------------------------------------- |
| C01 | Minimum on time |
| C02 | Minimum off time |
| C03 | Delay between starts of the 2 compressors |
| C04 | Rotation |

## Defrost parameter

| Parameter | Description |
| --------- | ---------------------------- |
| D01 | Start defrosting temperature |
| D02 | End defrost temperature |
| D03 | defrosting cycle |
| D04 | Maximum defrosting time |
| D05 | Minimum defrosting time |
| D06 | Defrost mode |
| D07 | Defrost heater control |
| D08 | Defrost AUTO set |

## EEV parameter

| Parameter | Description |
| --------- | --------------- |
| E01 | EEV 1 mode |
| E02 | Super heat 1 |
| E03 | Initial place 1 |
| E04 | EEV 2 mode |
| E05 | Super heat 2 |
| E06 | Initial place 2 |
| E07 | Minimum place |
| E08 | Defrost place |
| E09 | Cooling place |
| E10 | Low exhaust |
| E11 | High exhaust |

## Fan parameter

| Parameter | Description |
| --------- | ------------------------------------------------- |
| F01 | Fan parameter |
| F02 | Coil temperature in high speed fan mode (Cooling) |
| F03 | Coil temperature in low speed fan mode (Cooling) |
| F04 | Coil temperature when the fan stop (Cooling) |
| F05 | Coil temperature in high speed fan mode (Heating) |
| F06 | Coil temperature in low speed fan mode (Heating) |
| F07 | Coil temperature when the fan stop (Heating) |
| F08 | Fan start low speed running time |
| F09 | Fan stop low speed running time |
| F10 | Fan quantity |
| F11 | Fan speed control temp. |

## System parameter

| Parameter | Description |
| --------- | -------------------- |
| H01 | Automatic restarting |
| H02 | System quantity |
| H03 | 4-way valve polarity |
| H04 | 4-way valve control |
| H05 | Model |
| H06 | Type |
| H07 | Class |
| H08 | Capacity Control |
| H09 | Coil sensor function |
| H10 | Physical address |
| H11 | Baud rate |
| H12 | Parity bit |
| H13 | Stop bit |

## Water pump parameter

| Parameter | Description |
| --------- | ---------------------------------------------------------------- |
| R01 | Water pump mode |
| P02 | Water pump running cycle |
| P03 | Water pump running time |
| P04 | Delay in switching on the compressor after switching on the pump |
| P05 | Filter |
| P06 | Start filter 1 |
| P07 | Stop filter 1 |
| P08 | Start filter 2 |
| P09 | Stop filter 2 |

## Temp parameter

| Parameter | Description |
| --------- | ---------------------------------------------------- |
| R01 | Inlet water setting temperature (cooling) |
| R02 | Inlet water setting temperature (Heating) |
| R03 | Target setting temperature (Auto mode) |
| R04 | Cooling differential |
| R05 | Cooling stop differential |
| R06 | Heating differential |
| R07 | Heating stop differential |
| R08 | Minimum set point in Cooling |
| R09 | Maximum Cooling set point |
| R10 | Minimum Heating set point |
| R11 | Maximum Heating set point |
| R12 | Electrical ΔT6 |
| R13 | Electrical Ambient |
| R14 | Electrical Delay |
| R15 | Electrical force |
| R16 | Compensation |
| R17 | Maximum ΔT7 |
| R18 | Cooling compensation constant |
| R19 | Cooling compensation start air temperature |
| R20 | Heating compensation start air temperature |
| R21 | Whether enable heat recovery |
| R22 | The target temperature Of heat recovery |
| R23 | Temperature differential of heat recovery |
| R24 | Temperature to stop heat recovery |
| R25 | Temperature differential to stop heat recovery |
| R26 | Electric heater mode |
| R27 | Ambient temperature to start up antifreezing heater |
| R28 | Temperature differential to stop antifreezing heater |

## Water flow parameter

| Parameter | Description |
| --------- | ------------ |
| U01 | Flow meter |
| U02 | Pulse |
| U03 | Flow protect |
| U04 | Flow alarm |

## Switch state checking

| Parameter | Description |
| --------- | -------------------------- |
| S01 | System1 HP |
| S02 | System2 HP |
| S03 | System1 LP |
| S04 | System2 LP |
| S05 | Phase monitor |
| S06 | Water Flow switch |
| S07 | Electrical heater overload |
| S08 | COMP1 overload |
| S09 | COMP2 overload |
| S10 | On/Off switch |
| S11 | Mode switch |
| S12 | System protect |
| S13 | Water flow |

## Temp. checking

| Parameter | Description |
| --------- | ------------------------ |
| T01 | Suction temperature |
| T02 | Inlet water temp. |
| T03 | Outlet water temp |
| T04 | Coil temperature |
| T05 | Ambient temperature |
| T06 | Antifreeze 1 temperature |
| T07 | Antifreeze 2 temperature |
| T08 | Suction 1 temperature |
| T09 | Suction 2 temperature |
| T10 | Exhaust 1 temperature |
| T11 | Exhaust 2 temperature |
| T12 | Hot water temperature |
| T14 | None |

## Load output

| Parameter | Description |
| --------- | ----------------------------------- |
| O01 | Compressor 1 output |
| O02 | Compressor 2 output |
| O03 | Fan output (High speed) |
| O04 | Fan output (Low speed) |
| O05 | Circulate pump output |
| O06 | 4-way valve output |
| O07 | Heat element output |
| O08 | Alarm output |
| O09 | Spray valve output |
| O10 | Electronic Expansion valve 1 output |
| O11 | Electronic Expansion valve 2 output |