Breaking changes

IIDM

Disconnectors on parallel bars

Connecting coupling devices

When creating a coupling device, each side of the coupling device is now connected to more bars than previously. The logic depends on whether the sections on which the user asks the coupling device to be connected has a position defined or not:

  • If a section has no position defined, the corresponding side of the coupling device will only be connected to this section. image
  • If a section has a position defined but the opposite side has no position defined, the corresponding side of the coupling device will be connected to all the bars parallel to the section.
  • If both sections have positions defined but have different section index, each one will be connected to every bar parallel to the respective section. image
  • If both sections have positions defined and the same section index, each side will be connected to every bar except one. If the first side corresponds to the first busbar index or the second side corresponds to the last busbar index, the first side will be connected to every bar except the last one while the second side will be connected to every bar except the first one. If not, it will be the opposite. image

Make sure that you anticipate the new connections and don't recreate them manually.

Nota: only the disconnectors corresponding to the connections asked are closed, the others are open.

Naming of disconnectors

The were some inconsistencies in the naming of some disconnectors created during network modifications. Now, every disconnector created this way has a name based on the following format: <prefix>_DISCONNECTOR_<node1_number>_<node2_number>.

For example, when creating a coupling device, the names can change from:

<iidm:switch id="vl1_BREAKER" kind="BREAKER" retained="true" open="false" node1="36" node2="37"/>
<iidm:switch id="vl1_DISCONNECTOR_0" kind="DISCONNECTOR" retained="false" open="false" node1="0" node2="36"/>
<iidm:switch id="vl1_DISCONNECTOR_1" kind="DISCONNECTOR" retained="false" open="false" node1="1" node2="37"/>
<iidm:switch id="vl1_DISCONNECTOR_36_2" kind="DISCONNECTOR" retained="false" open="true" node1="36" node2="2"/>
<iidm:switch id="vl1_DISCONNECTOR_37_3" kind="DISCONNECTOR" retained="false" open="true" node1="37" node2="3"/>

to:

<iidm:switch id="vl1_BREAKER" kind="BREAKER" retained="true" open="false" node1="36" node2="37"/>
<iidm:switch id="vl1_DISCONNECTOR_36_0" kind="DISCONNECTOR" retained="false" open="false" node1="36" node2="0"/>
<iidm:switch id="vl1_DISCONNECTOR_36_2" kind="DISCONNECTOR" retained="false" open="true" node1="36" node2="2"/>
<iidm:switch id="vl1_DISCONNECTOR_37_1" kind="DISCONNECTOR" retained="false" open="false" node1="37" node2="1"/>
<iidm:switch id="vl1_DISCONNECTOR_37_3" kind="DISCONNECTOR" retained="false" open="true" node1="37" node2="3"/>

Note that the order of the disconnectors creation also changed.

Custom connection/disconnection of terminals

Two methods Terminal.connect(Predicate<Switch> isTypeSwitchToOperate) and disconnect(Predicate<Switch> isSwitchOpenable) were added. They allow the user to specify predicates indicating what kind of switch can be operated during the opening or which switch can be opened during a disconnection. Defaults predicates are made available in the SwitchPredicates class.

Connect

Previously, the connect() method used to find the paths going from the terminal to a busbar section that did not contain an open disconnector and sort them by size.

The connect(Predicate<Switch> isTypeSwitchToOperate) method will now find all paths going from the terminal to a busbar section that do not contain an open switch that is not of the type of switch the user wants to operate (ie. not corresponding to the isTypeSwitchToOperate parameter). The paths will be sorted by the number of open switches and by the size of the paths. If there is at least one path, the shortest path will be selected and all open switches on the path will be closed.

If no predicate is used in the connect() method, only the closed non-fictional breakers will be considered.

Disconnect

Previously, the disconnect() method used to look for paths going from the terminal to a busbar section that did not contain an open disconnector (ie. a path with an open breaker would have been considered). Each path was then travelled until a breaker was encountered. Those breakers were then opened and the paths considered open. If a path could not be opened, the method would stop and return false but paths that were just opened would stay open, which means the terminal would become half-way disconnected.

The method disconnect(Predicate<Switch> isSwitchOpenable) now look for for paths going from the terminal to a busbar section that do not contain an open switch (its type does not matter). If at least one such path exists, the method will then compute the list of switches it has to open on each path in order to open them, taking into account the predicate specified by the user and telling what kind of switch can be opened. If a switch has been found on each path, those switches are opened. If not, the paths stay as they are and the method returns false.

If no predicate is used in the disconnect() method, only the closed breakers will be considered as being openable.

Get side on three windings transformer leg

TODO

Limit violations for three windings transformers

TODO

TwoSides and ThreeSides

Starting from this release,

  • Branch.Side replaced by com.powsybl.iidm.network.TwoSides
  • Hvdc.Side replaced by com.powsybl.iidm.network.TwoSides
  • ThreeWindingsTransformer.Side replaced by com.powsybl.iidm.network.ThreeSides
  • Measurement.Side replaced by com.powsybl.iidm.network.ThreeSides

JSON support added and XML serialization refactoring

TODO

LoadFlowResult

A LoadFlowResult introduced a dedicated object to store a slack bus result. A single SlackBusResult object gives access to the id of the slack bus used during the calculation and the associated active power mismatch in MW (getActivePowerMismatch()). As several slack buses can be used in a single synchronous component calculation, a LoadFlowResult.ComponentResult now contains a list of SlackBusResult-s.

New ComponentResult status NO_CALCULATION has been added, meaning that the component was not calculated, e.g. de-energized component without any voltage support. ComponentResult status SOLVER_FAILED status has been removed, please use FAILED status as a replacement if you were using SOLVER_FAILED. For more details about status, a dedicated String field has been added: use getStatusText for a more detailed description.

ComponentResult can now have metrics (list of key/value pairs) just like the global LoadFlowResult.

And finally, load flow results give access now to the angle reference bus id through the method getReferenceBusId().

Methods getSlackBusId(), getSlackBusActivePowerMismatch() and isOk() are deprecated.

As par of these changes, LoadFlowResult JSON serialization format is bumped from version 1.3 to version 1.4.