doorlock UDP protocol

In the example configuration, the service sends to the multicast UDP group 239.0.0.1 port 3300.

Messages are encoded as JSON. All messages have attribute event which determines the event type being transmitted.

Event Types

doorUnlock

Fired when the door is unlocked successfully. Passes the following addditional parameters:

  • user: The username of the person who swiped their card
  • label: A user-specific identifier for the card, for example, "metrocard".
  • id: The card's serial number, encoded as base16.

disabledCard

Fired when the door is not unlocked, because a known card is disabled in the database.

Passes the same parameters as doorUnlock.

unknownCard

Fired when the door is not unlocked, because an unknown card was used. Passes the following additional parameter:

  • id: The card's serial number, encoded as base16.

exitButton

Fired when the door's exit button is pressed.

Has no parameters.

fridgeAlarm

Fired when the fridge door has been left open for too long. Passes the following additional parameter:

  • time: The number of seconds the fridge door has been left open.

fridgeAlarmStop

Fired when the fridge door was closed after the alarm was triggered.

Has no parameters.