ASCII transmission, the command is terminated by the carriage return and line feed key
th1_mov=xx
: set the motion detection threshold within 2.8 meters, the default value is 30th2_mov=xx
: set the motion detection threshold within 2.8~8 meters, the default value is 15th3_mov=xx
: set the motion detection threshold more than 8 meters, the default value is 6th1_occ=xx
: set the presence detection threshold within 2.8 meters, the default value is 30th2_occ=xx
: set the presence detection threshold within 2.8~8 meters, the default value is 15th3_occ=xx
: set the presence detection threshold more than 8 meters, the default value is 6rmax=xx
: set the maximum detection threshold, the default value is 60eff_th=xx
: in the presence detection, the target detection for a period of time is counted; when the ratio of the detected target times to the total detected times exceeds (eff_th/100), it is determined that there is a real target, default value is 20accu_num=xx
: chirp accumulation times, increasing this value can appropriately reduce the influence of noise, the default value is 8occ_st=xx
: In the presence detection, the time between canceling the chirp, the unit is ms, when the value is appropriate, the higher the target strength of the presence detection, the default value is 250test_mode=xx
: Set the test mode, the default value is 0
- When
test_mode=0
, output detection status and target distance - When
test_mode=1
, output detection status, target distance, signal strength - When
test_mode=2
, output the signal spectrum detected by the current occ - When
test_mode=3
, output the signal spectrum detected by the current mov - When
test_mode=4
, enter the spot frequency mode from the normal working mode, or enter the normal working mode from the spot frequency mode
opt_mode=xx
: Set the format of the detection target output, the default value is 0
- When
opt_mode=0
, the detection result is displayed in characters through the serial port - When
opt_mode=1
, the tx port of the serial port is configured as a common GPIO port, and the target is detected with a high level, and the duration of the high level is led_tim
led_tim=xx
: high level duration, unit is s, the default value is 1get_all
: Get all current parameter valuessave
: save the above parametersVER
: get version numberupdate_fir
: online updatevt=xx
: In point frequency mode, set VT voltage (mv)