diff --git a/examples/NREL-example.md b/examples/NREL-example.md
index 7c30d9f7..c26d1c9b 100644
--- a/examples/NREL-example.md
+++ b/examples/NREL-example.md
@@ -10,7 +10,7 @@ This is an example building provided by the National Renewable Energy Laboratory
## Queries
| Description | Query URL |
|-------------|-----------|
-| Zone/room temperature sensors | [Query Link](https://query.open223.info/?query=PREFIX+s223%3A+%3Chttp%3A%2F%2Fdata.ashrae.org%2Fstandard223%23%3E+PREFIX+unit%3A+%3Chttp%3A%2F%2Fqudt.org%2Fvocab%2Funit%2F%3E+PREFIX+rdfs%3A+%3Chttp%3A%2F%2Fwww.w3.org%2F2000%2F01%2Frdf-schema%23%3E+PREFIX+rdf%3A+%3Chttp%3A%2F%2Fwww.w3.org%2F1999%2F02%2F22-rdf-syntax-ns%23%3E+PREFIX+quantitykind%3A+%3Chttp%3A%2F%2Fqudt.org%2Fvocab%2Fquantitykind%2F%3E+PREFIX+qudt%3A+%3Chttp%3A%2F%2Fqudt.org%2Fschema%2Fqudt%2F%3E+PREFIX+sh%3A+%3Chttp%3A%2F%2Fwww.w3.org%2Fns%2Fshacl%23%3E+PREFIX+owl%3A+%3Chttp%3A%2F%2Fwww.w3.org%2F2002%2F07%2Fowl%23%3E+SELECT+%3Flocation+%3Fsensor+WHERE+%7B%0A++++%3Fsensor+rdf%3Atype%2Frdfs%3AsubClassOf%2A+s223%3ASensor+.%0A++++%3Fsensor+s223%3Aobserves+%3Fproperty+.%0A++++%3Fproperty+qudt%3AhasQuantityKind+quantitykind%3ATemperature+.%0A++++%3Fsensor+s223%3AhasObservationLocation+%3Flocation%0A%7D%0A&url=https%3A%2F%2Fmodels.open223.info%2Fcompiled%2Fnrel-example.ttl) |
+| Zone/room temperature sensors | Query Link |
## Model Components
| Parent Class | Class | Instances |
diff --git a/examples/design-patterns.md b/examples/design-patterns.md
index e02b8c8a..fbfd74a8 100644
--- a/examples/design-patterns.md
+++ b/examples/design-patterns.md
@@ -7,7 +7,27 @@ This file contains the Turtle code supporting the set of design patterns present
The model was created using [TopQuadrant](https://www.topquadrant.com/) TopBraid Composer Maestro Edition.
## Downloads
+
+- Turtle file (compiled) (original)
+- JSON-LD file (original)
## Queries
-## Model Components
\ No newline at end of file
+## Model Components
+| Parent Class | Class | Instances |
+|------------|-------|----------------|
+| [Equipment](https://explore.open223.info/s223/Equipment.html) | [Motor](https://explore.open223.info/s223/Motor.html) | 6 |
+| [Equipment](https://explore.open223.info/s223/Equipment.html) | [ElectricBreaker](https://explore.open223.info/s223/ElectricBreaker.html) | 5 |
+| [Equipment](https://explore.open223.info/s223/Equipment.html) | [Luminaire](https://explore.open223.info/s223/Luminaire.html) | 4 |
+| [Equipment](https://explore.open223.info/s223/Equipment.html) | [OccupantMotionSensor](https://explore.open223.info/s223/OccupantMotionSensor.html) | 4 |
+| [Equipment](https://explore.open223.info/s223/Equipment.html) | [Actuator](https://explore.open223.info/s223/Actuator.html) | 2 |
+| [Equipment](https://explore.open223.info/s223/Equipment.html) | [Controller](https://explore.open223.info/s223/Controller.html) | 1 |
+| [Connection](https://explore.open223.info/s223/Connection.html) | [ElectricWire](https://explore.open223.info/s223/ElectricWire.html) | 12 |
+| [ConnectionPoint](https://explore.open223.info/s223/ConnectionPoint.html) | [InletConnectionPoint](https://explore.open223.info/s223/InletConnectionPoint.html) | 21 |
+| [ConnectionPoint](https://explore.open223.info/s223/ConnectionPoint.html) | [OutletConnectionPoint](https://explore.open223.info/s223/OutletConnectionPoint.html) | 19 |
+| [DomainSpace](https://explore.open223.info/s223/DomainSpace.html) | [](https://explore.open223.info/s223/.html) | 5 |
+| [Property](https://explore.open223.info/s223/Property.html) | [QuantifiableProperty](https://explore.open223.info/s223/QuantifiableProperty.html) | 6 |
+| [Property](https://explore.open223.info/s223/Property.html) | [EnumeratedActuatableProperty](https://explore.open223.info/s223/EnumeratedActuatableProperty.html) | 4 |
+| [Property](https://explore.open223.info/s223/Property.html) | [EnumeratedObservableProperty](https://explore.open223.info/s223/EnumeratedObservableProperty.html) | 4 |
+| [Property](https://explore.open223.info/s223/Property.html) | [EnumerableProperty](https://explore.open223.info/s223/EnumerableProperty.html) | 3 |
+
diff --git a/examples/lbnl-example.md b/examples/lbnl-example.md
index 0ab49e8b..a05fba35 100644
--- a/examples/lbnl-example.md
+++ b/examples/lbnl-example.md
@@ -13,7 +13,7 @@ This is an example building provided by Lawrence Berkeley National Laboratory
## Queries
| Description | Query URL |
|-------------|-----------|
-| Zone/room temperature sensors | [Query Link](https://query.open223.info/?query=PREFIX+s223%3A+%3Chttp%3A%2F%2Fdata.ashrae.org%2Fstandard223%23%3E+PREFIX+unit%3A+%3Chttp%3A%2F%2Fqudt.org%2Fvocab%2Funit%2F%3E+PREFIX+rdfs%3A+%3Chttp%3A%2F%2Fwww.w3.org%2F2000%2F01%2Frdf-schema%23%3E+PREFIX+rdf%3A+%3Chttp%3A%2F%2Fwww.w3.org%2F1999%2F02%2F22-rdf-syntax-ns%23%3E+PREFIX+quantitykind%3A+%3Chttp%3A%2F%2Fqudt.org%2Fvocab%2Fquantitykind%2F%3E+PREFIX+qudt%3A+%3Chttp%3A%2F%2Fqudt.org%2Fschema%2Fqudt%2F%3E+PREFIX+sh%3A+%3Chttp%3A%2F%2Fwww.w3.org%2Fns%2Fshacl%23%3E+PREFIX+owl%3A+%3Chttp%3A%2F%2Fwww.w3.org%2F2002%2F07%2Fowl%23%3E+SELECT+%3Flocation+%3Fsensor+WHERE+%7B%0A++++%3Fsensor+rdf%3Atype%2Frdfs%3AsubClassOf%2A+s223%3ASensor+.%0A++++%3Fsensor+s223%3Aobserves+%3Fproperty+.%0A++++%3Fproperty+qudt%3AhasQuantityKind+quantitykind%3ATemperature+.%0A++++%3Fsensor+s223%3AhasObservationLocation+%3Flocation%0A%7D%0A&url=https%3A%2F%2Fmodels.open223.info%2Fcompiled%2Flbnl-example.ttl) |
+| Zone/room temperature sensors | Query Link |
## Model Components
| Parent Class | Class | Instances |
diff --git a/examples/nist-example.md b/examples/nist-example.md
index 8e39731b..0e1618ca 100644
--- a/examples/nist-example.md
+++ b/examples/nist-example.md
@@ -12,10 +12,10 @@ The schematics of the air and hydronic systems can be found [here](../_static/sc
## Queries
| Description | Query URL |
|-------------|-----------|
-| Zone/room temperature sensors | [Query Link](https://query.open223.info/?query=PREFIX+s223%3A+%3Chttp%3A%2F%2Fdata.ashrae.org%2Fstandard223%23%3E+PREFIX+unit%3A+%3Chttp%3A%2F%2Fqudt.org%2Fvocab%2Funit%2F%3E+PREFIX+rdfs%3A+%3Chttp%3A%2F%2Fwww.w3.org%2F2000%2F01%2Frdf-schema%23%3E+PREFIX+rdf%3A+%3Chttp%3A%2F%2Fwww.w3.org%2F1999%2F02%2F22-rdf-syntax-ns%23%3E+PREFIX+quantitykind%3A+%3Chttp%3A%2F%2Fqudt.org%2Fvocab%2Fquantitykind%2F%3E+PREFIX+qudt%3A+%3Chttp%3A%2F%2Fqudt.org%2Fschema%2Fqudt%2F%3E+PREFIX+sh%3A+%3Chttp%3A%2F%2Fwww.w3.org%2Fns%2Fshacl%23%3E+PREFIX+owl%3A+%3Chttp%3A%2F%2Fwww.w3.org%2F2002%2F07%2Fowl%23%3E+SELECT+%3Flocation+%3Fsensor+WHERE+%7B%0A++++%3Fsensor+rdf%3Atype%2Frdfs%3AsubClassOf%2A+s223%3ASensor+.%0A++++%3Fsensor+s223%3Aobserves+%3Fproperty+.%0A++++%3Fproperty+qudt%3AhasQuantityKind+quantitykind%3ATemperature+.%0A++++%3Fsensor+s223%3AhasObservationLocation+%3Flocation%0A%7D%0A&url=https%3A%2F%2Fmodels.open223.info%2Fcompiled%2Fnist-example.ttl) |
-| Search for all the sensors along the connections and the associated property they're observing. | [Query Link](https://query.open223.info/?query=PREFIX+s223%3A+%3Chttp%3A%2F%2Fdata.ashrae.org%2Fstandard223%23%3E+PREFIX+unit%3A+%3Chttp%3A%2F%2Fqudt.org%2Fvocab%2Funit%2F%3E+PREFIX+rdfs%3A+%3Chttp%3A%2F%2Fwww.w3.org%2F2000%2F01%2Frdf-schema%23%3E+PREFIX+rdf%3A+%3Chttp%3A%2F%2Fwww.w3.org%2F1999%2F02%2F22-rdf-syntax-ns%23%3E+PREFIX+quantitykind%3A+%3Chttp%3A%2F%2Fqudt.org%2Fvocab%2Fquantitykind%2F%3E+PREFIX+qudt%3A+%3Chttp%3A%2F%2Fqudt.org%2Fschema%2Fqudt%2F%3E+PREFIX+sh%3A+%3Chttp%3A%2F%2Fwww.w3.org%2Fns%2Fshacl%23%3E+PREFIX+owl%3A+%3Chttp%3A%2F%2Fwww.w3.org%2F2002%2F07%2Fowl%23%3E+SELECT+%3Fsegment+%3Fchannel+%3Fproperty_id+WHERE+%7B%0A++++%3Fsegment+a+s223%3AConnection+.%0A++++%3Fchannel+a%2Frdfs%3AsubClassOf%2A+s223%3ASensor+.%0A++++%3Fchannel+s223%3Aobserves+%3Fproperty_id+.%0A%7D%0A&url=https%3A%2F%2Fmodels.open223.info%2Fcompiled%2Fnist-example.ttl) |
-| Sensors in AHU1 and what units the properties are measured in | [Query Link](https://query.open223.info/?query=PREFIX+s223%3A+%3Chttp%3A%2F%2Fdata.ashrae.org%2Fstandard223%23%3E+PREFIX+unit%3A+%3Chttp%3A%2F%2Fqudt.org%2Fvocab%2Funit%2F%3E+PREFIX+rdfs%3A+%3Chttp%3A%2F%2Fwww.w3.org%2F2000%2F01%2Frdf-schema%23%3E+PREFIX+rdf%3A+%3Chttp%3A%2F%2Fwww.w3.org%2F1999%2F02%2F22-rdf-syntax-ns%23%3E+PREFIX+quantitykind%3A+%3Chttp%3A%2F%2Fqudt.org%2Fvocab%2Fquantitykind%2F%3E+PREFIX+qudt%3A+%3Chttp%3A%2F%2Fqudt.org%2Fschema%2Fqudt%2F%3E+PREFIX+sh%3A+%3Chttp%3A%2F%2Fwww.w3.org%2Fns%2Fshacl%23%3E+PREFIX+owl%3A+%3Chttp%3A%2F%2Fwww.w3.org%2F2002%2F07%2Fowl%23%3E+SELECT+%3Fchannel+%3Fproperty_id+%3Funit+WHERE+%7B%0A++++BIND%28IBAL%3AAHU_1+as+%3Fahu%29+%7B%0A++++%7D%0A++++UNION+%7B%0A++++++++%3Fahu+s223%3Acontains+%3Fequipment+.%0A++++++++%3Fchannel+s223%3AhasObservationLocation+%3Fequipment+.%0A++++++++%3Fchannel+s223%3Aobserves+%3Fproperty_id+.%0A++++++++%3Fproperty_id+qudt%3AhasUnit+%3Funit+.%0A++++%7D%0A++++UNION+%7B%0A++++++++%3Fahu+s223%3Acontains+%3Fequipment+.%0A++++++++%3Fequipment+s223%3AconnectedThrough+%3Fconnection+.%0A++++++++%3Fchannel+s223%3AhasObservationLocation+%3Fconnection+.%0A++++++++%3Fchannel+s223%3Aobserves+%3Fproperty_id+.%0A++++++++%3Fproperty_id+qudt%3AhasUnit+%3Funit+.%0A++++%7D%0A++++UNION+%7B%0A++++++++%3Fahu+s223%3Acontains+%3Fequipment+.%0A++++++++%3Fequipment+s223%3AhasConnectionPoint+%3FconnectionPoint+.%0A++++++++%3Fchannel+s223%3AhasObservationLocation+%3FconnectionPoint+.%0A++++++++%3Fchannel+s223%3Aobserves+%3Fproperty_id+.%0A++++++++%3Fproperty_id+qudt%3AhasUnit+%3Funit+.%0A++++%7D%0A%7D%0A&url=https%3A%2F%2Fmodels.open223.info%2Fcompiled%2Fnist-example.ttl) |
-| Find the downstream equipment for AHU1. | [Query Link](https://query.open223.info/?query=PREFIX+s223%3A+%3Chttp%3A%2F%2Fdata.ashrae.org%2Fstandard223%23%3E+PREFIX+unit%3A+%3Chttp%3A%2F%2Fqudt.org%2Fvocab%2Funit%2F%3E+PREFIX+rdfs%3A+%3Chttp%3A%2F%2Fwww.w3.org%2F2000%2F01%2Frdf-schema%23%3E+PREFIX+rdf%3A+%3Chttp%3A%2F%2Fwww.w3.org%2F1999%2F02%2F22-rdf-syntax-ns%23%3E+PREFIX+quantitykind%3A+%3Chttp%3A%2F%2Fqudt.org%2Fvocab%2Fquantitykind%2F%3E+PREFIX+qudt%3A+%3Chttp%3A%2F%2Fqudt.org%2Fschema%2Fqudt%2F%3E+PREFIX+sh%3A+%3Chttp%3A%2F%2Fwww.w3.org%2Fns%2Fshacl%23%3E+PREFIX+owl%3A+%3Chttp%3A%2F%2Fwww.w3.org%2F2002%2F07%2Fowl%23%3E+SELECT+%3FconnectionDown+%3FconnectionDown2+WHERE+%7B%0A++++BIND%28IBAL%3AAHU_1+as+%3Fahu%29+%7B%0A%09%7D%0A%09UNION+%7B%0A%09%3Fahu+s223%3AhasConnectionPoint+%3FconnectionPoint+.%0A%09%3FconnectionPoint+a+s223%3AOutletConnectionPoint+.%0A%09%3FconnectionPoint+s223%3AhasMedium+s223%3AMedium-Air+.%0A%09%3FconnectionPoint+s223%3AconnectsThrough+%3Fsegment+.%0A%09%3Fsegment+s223%3AconnectsTo+%3Fjunction+.%0A++++%3Fjunction+s223%3AconnectedTo+%3FconnectionDown+.%0A++++%3FconnectionDown+a+s223%3ATerminalUnit+.%0A%09%7D%0A%09UNION+%7B%0A%09%3Fahu+s223%3AhasConnectionPoint+%3FconnectionPoint+.%0A%09%3FconnectionPoint+a+s223%3AOutletConnectionPoint+.%0A%09%3FconnectionPoint+s223%3AhasMedium+s223%3AMedium-Air+.%0A%09%3FconnectionPoint+s223%3AconnectsThrough+%3Fsegment+.%0A%09%3Fsegment+s223%3AconnectsTo+%3Fjunction+.%0A++++%3Fjunction+s223%3AconnectedTo+%3FconnectionDown+.%0A++++%3FconnectionDown+a+s223%3AJunction+.%0A%09%3FconnectionDown+s223%3AconnectedTo+%3FconnectionDown2+.%0A%09%3FconnectionDown2+a+s223%3ATerminalUnit+.%0A%09%7D%0A%7D%0A&url=https%3A%2F%2Fmodels.open223.info%2Fcompiled%2Fnist-example.ttl) |
+| Zone/room temperature sensors | Query Link |
+| Search for all the sensors along the connections and the associated property they're observing. | Query Link |
+| Sensors in AHU1 and what units the properties are measured in | Query Link |
+| Find the downstream equipment for AHU1. | Query Link |
## Model Components
| Parent Class | Class | Instances |
diff --git a/models/lbnl-example.jsonld b/models/lbnl-example.jsonld
index 7f7136b2..44a763b1 100644
--- a/models/lbnl-example.jsonld
+++ b/models/lbnl-example.jsonld
@@ -1,116 +1,128 @@
[
{
- "@id": "urn:ex/vav-507-reheat-coil",
+ "@id": "urn:ex/vav-531-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-507-reheat-coil-air-in"
- },
- {
- "@id": "urn:ex/vav-507-reheat-coil-air-out"
- },
- {
- "@id": "urn:ex/vav-507-reheat-coil-water-in"
- },
- {
- "@id": "urn:ex/vav-507-reheat-coil-water-out"
+ "@id": "urn:ex/vav-531-pipe-hot-water-return-before-valve"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-520-damper-position",
+ "@id": "urn:ex/vav-510-discharge-air-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-535-colder-supply-air-requests",
+ "@id": "urn:ex/room-114",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/room-114-hvac-domain"
}
]
},
{
- "@id": "urn:ex/vav-536-reheat-coil-water-in",
+ "@id": "urn:ex/vav-535-reheat-coil-air-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-536-hot-water-in-connection"
+ "@id": "urn:ex/connection-to-room-311"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-535-heating-pid-output"
+ },
+ {
+ "@id": "urn:ex/vav-535-more-heat-requests"
}
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-536-hot-water-in"
+ "@id": "urn:ex/vav-535-air-out"
}
]
},
{
- "@id": "urn:ex/vav-506-air-out",
+ "@id": "urn:ex/vav-513-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-106-107"
+ "@id": "urn:ex/vav-513-reheat-coil-valve-in"
+ },
+ {
+ "@id": "urn:ex/vav-513-reheat-coil-valve-out"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-506-discharge-air-flow"
+ "@id": "urn:ex/vav-513-reheat-coil-valve-command"
},
{
- "@id": "urn:ex/vav-506-discharge-air-flow-setpoint"
- },
+ "@id": "urn:ex/vav-513-reheat-coil-valve-position"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-524-damper-command",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-506-discharge-air-temp"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-506-discharge-air-temp-setpoint"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/room-211-in",
+ "@id": "urn:ex/vav-535-reheat-coil-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-211"
+ "@id": "urn:ex/vav-535-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -120,257 +132,278 @@
]
},
{
- "@id": "urn:ex/zone-314",
+ "@id": "urn:ex/vav-504-reheat-coil-air-out",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-314-hvac-domain"
+ "@id": "urn:ex/connection-to-room-105"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/zone-314-cooling-setpoint"
- },
- {
- "@id": "urn:ex/zone-314-heating-setpoint"
- },
- {
- "@id": "urn:ex/zone-314-occupancy"
- },
- {
- "@id": "urn:ex/zone-314-occupancy-override"
+ "@id": "urn:ex/vav-504-heating-pid-output"
},
{
- "@id": "urn:ex/zone-314-temp"
- },
+ "@id": "urn:ex/vav-504-more-heat-requests"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/zone-314-window-switch-on-off"
+ "@id": "urn:ex/vav-504-air-out"
}
]
},
{
- "@id": "urn:ex/vav-505-heating-pid-output",
+ "@id": "urn:ex/connection-to-room-112-114",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-521-more-heat-requests",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-510-damper-position",
+ "@id": "urn:ex/room-109-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/connection-to-room-109"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-534-reheat-coil",
+ "@id": "urn:ex/room-307-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-534-reheat-coil-air-in"
- },
- {
- "@id": "urn:ex/vav-534-reheat-coil-air-out"
- },
- {
- "@id": "urn:ex/vav-534-reheat-coil-water-in"
+ "@id": "urn:ex/room-307-in"
},
{
- "@id": "urn:ex/vav-534-reheat-coil-water-out"
+ "@id": "urn:ex/room-307-out"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-530-discharge-air-temp-sensor",
+ "@id": "urn:ex/vav-523-hot-water-out-connection",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:ex/vav-530-air-out"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-530-discharge-air-temp"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-521-hot-water-out",
+ "@id": "urn:ex/vav-502-damper",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-521-hot-water-out-connection"
+ "@id": "urn:ex/vav-502-damper-in"
+ },
+ {
+ "@id": "urn:ex/vav-502-damper-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-502-damper-command"
+ },
+ {
+ "@id": "urn:ex/vav-502-damper-position"
}
]
},
{
- "@id": "urn:ex/vav-538-air-in",
+ "@id": "urn:ex/vav-514-discharge-air-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-504-reheat-coil-water-out",
+ "@id": "urn:ex/vav-524-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-504-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-524-air-in"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-524-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/vav-513-reheat-coil-valve-in",
+ "@id": "urn:ex/zone-101-window-switch-on-off",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-513-pipe-hot-water-return-before-valve"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/room-107",
+ "@type": [
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/room-107-hvac-domain"
}
]
},
{
- "@id": "urn:ex/vav-527-heating-pid-output",
+ "@id": "urn:ex/vav-506-hot-water-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/vav-506-hot-water-in-connection"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/zone-110-cooling-setpoint",
+ "@id": "urn:ex/office-ahu-ma-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/office-ahu-air-filter-in"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/office-ahu-ma-temp"
}
]
},
{
- "@id": "urn:ex/room-107-out",
+ "@id": "urn:ex/vav-528-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/connection-to-room-302"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-528-discharge-air-flow"
+ },
+ {
+ "@id": "urn:ex/vav-528-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-528-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-528-discharge-air-temp-setpoint"
+ }
]
},
{
- "@id": "urn:ex/vav-536-reheat-coil-valve-out",
+ "@id": "urn:ex/vav-511-more-heat-requests",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-536-hot-water-out-connection"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-534-air-in",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-536-hot-water-out"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-516-reheat-coil-water-in",
+ "@id": "urn:ex/vav-502-reheat-coil-water-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-516-hot-water-in-connection"
+ "@id": "urn:ex/vav-502-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -380,113 +413,93 @@
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-516-hot-water-in"
+ "@id": "urn:ex/vav-502-hot-water-in"
}
]
},
{
- "@id": "urn:ex/vav-509-discharge-air-flow-sensor",
+ "@id": "urn:ex/vav-523-discharge-air-flow",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:ex/vav-509-air-in"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/vav-509-discharge-air-flow"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
- ]
- },
- {
- "@id": "urn:ex/office-ahu-ea-damper-position",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-505-reheat-coil-valve-position",
+ "@id": "urn:ex/room-202-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/connection-to-room-202"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/office-ahu-clg-coil-valve-out",
+ "@id": "urn:ex/vav-537-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/office-ahu-chilled-water-out-connection"
- }
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-537-air-in"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/office-ahu-chilled-water-out"
+ "@id": "urn:ex/vav-537-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/vav-527-hot-water-in",
+ "@id": "urn:ex/vav-535-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-527-hot-water-in-connection"
+ "@id": "urn:ex/vav-535-reheat-coil-valve-in"
+ },
+ {
+ "@id": "urn:ex/vav-535-reheat-coil-valve-out"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
}
- ]
- },
- {
- "@id": "urn:ex/vav-532-reheat-coil-water-out",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-532-pipe-hot-water-return-before-valve"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:ex/vav-535-reheat-coil-valve-command"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-535-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-538-cooling-pid-output",
+ "@id": "urn:ex/vav-514-heating-pid-output",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -502,46 +515,23 @@
]
},
{
- "@id": "urn:ex/vav-502-hot-water-out-connection",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ]
- },
- {
- "@id": "urn:ex/room-213-in",
+ "@id": "urn:ex/vav-510-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-213"
+ "@id": "urn:ex/vav-510-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ]
- },
- {
- "@id": "urn:ex/room-114",
- "@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
- ],
- "http://data.ashrae.org/standard223#encloses": [
- {
- "@id": "urn:ex/room-114-hvac-domain"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-513-discharge-air-flow",
+ "@id": "urn:ex/vav-535-discharge-air-flow",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -562,74 +552,78 @@
]
},
{
- "@id": "urn:ex/zone-305",
+ "@id": "urn:ex/vav-537-colder-supply-air-requests",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
- ],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/room-305-hvac-domain"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-505-reheat-coil",
+ "@type": [
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/zone-305-cooling-setpoint"
- },
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/zone-305-heating-setpoint"
+ "@id": "urn:ex/vav-505-reheat-coil-air-in"
},
{
- "@id": "urn:ex/zone-305-occupancy"
+ "@id": "urn:ex/vav-505-reheat-coil-air-out"
},
{
- "@id": "urn:ex/zone-305-occupancy-override"
+ "@id": "urn:ex/vav-505-reheat-coil-water-in"
},
{
- "@id": "urn:ex/zone-305-temp"
- },
+ "@id": "urn:ex/vav-505-reheat-coil-water-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "urn:ex/zone-305-window-switch-on-off"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/vav-540-reheat-coil-valve",
+ "@id": "urn:ex/zone-108-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-540-reheat-coil-valve-in"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-540-reheat-coil-valve-out"
+ "@id": "urn:ex/room-108-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "urn:ex/zone-108-temp"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/room-202-out",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-540-reheat-coil-valve-command"
- },
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-540-reheat-coil-valve-position"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/zone-104-heating-setpoint",
+ "@id": "urn:ex/zone-212-temp",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -643,373 +637,321 @@
]
},
{
- "@id": "urn:ex/office-ahu-moisture-eliminator",
+ "@id": "urn:ex/vav-534-heating-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#AirFilter",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Filter"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/office-ahu-moisture-eliminator-in"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/office-ahu-moisture-eliminator-out"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/room-203-hvac-domain",
+ "@id": "urn:ex/vav-529-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/room-203-in"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-203-out"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-514-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/vav-515-colder-supply-air-requests",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-534-air-in",
+ "@id": "urn:ex/office-ahu-air-filter-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/office-ahu-duct-after-oa-ra-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/zone-302-cooling-setpoint",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/office-ahu-ma-temp"
}
]
},
{
- "@id": "urn:ex/zone-305-temp-sensor",
+ "@id": "urn:ex/vav-520-damper",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-305-hvac-domain"
+ "@id": "urn:ex/vav-520-damper-in"
+ },
+ {
+ "@id": "urn:ex/vav-520-damper-out"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/zone-305-temp"
+ "@id": "urn:ex/vav-520-damper-command"
+ },
+ {
+ "@id": "urn:ex/vav-520-damper-position"
}
]
},
{
- "@id": "urn:ex/vav-520-reheat-coil-air-in",
+ "@id": "urn:ex/vav-519-reheat-coil-valve-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-520-duct-after-damper"
+ "@id": "urn:ex/vav-519-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-534-discharge-air-flow-setpoint",
+ "@id": "urn:ex/vav-503-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:ex/vav-503-pipe-hot-water-return-before-valve"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-539-reheat-coil-air-out",
+ "@id": "urn:ex/vav-505-hot-water-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-214"
+ "@id": "urn:ex/vav-505-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-539-heating-pid-output"
- },
- {
- "@id": "urn:ex/vav-539-more-heat-requests"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-539-air-out"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/room-101-hvac-domain",
+ "@id": "urn:ex/vav-508-duct-after-damper",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/room-101-in"
- },
- {
- "@id": "urn:ex/room-101-out"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-529-reheat-coil-water-in",
+ "@id": "urn:ex/office-ahu-clg-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-529-hot-water-in-connection"
- }
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/office-ahu-clg-coil-valve"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/vav-529-hot-water-in"
+ "@id": "urn:ex/office-ahu-clg-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/vav-532-damper-out",
+ "@id": "urn:ex/room-104",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-532-duct-after-damper"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-532-colder-supply-air-requests"
- },
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "urn:ex/vav-532-cooling-pid-output"
+ "@id": "urn:ex/room-104-hvac-domain"
}
]
},
{
- "@id": "urn:ex/vav-540-air-out",
+ "@id": "urn:ex/vav-518-discharge-air-flow-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/connection-to-room-215"
- }
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-540-discharge-air-flow"
- },
- {
- "@id": "urn:ex/vav-540-discharge-air-flow-setpoint"
- },
- {
- "@id": "urn:ex/vav-540-discharge-air-temp"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-540-discharge-air-temp-setpoint"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-520-reheat-coil-valve-out",
+ "@id": "urn:ex/zone-313-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-520-hot-water-out-connection"
- }
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-520-hot-water-out"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-524-air-out",
+ "@id": "urn:ex/zone-313",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/connection-to-room-210"
+ "@id": "urn:ex/room-313-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-524-discharge-air-flow"
+ "@id": "urn:ex/zone-313-cooling-setpoint"
},
{
- "@id": "urn:ex/vav-524-discharge-air-flow-setpoint"
+ "@id": "urn:ex/zone-313-heating-setpoint"
},
{
- "@id": "urn:ex/vav-524-discharge-air-temp"
+ "@id": "urn:ex/zone-313-occupancy"
},
{
- "@id": "urn:ex/vav-524-discharge-air-temp-setpoint"
+ "@id": "urn:ex/zone-313-occupancy-override"
+ },
+ {
+ "@id": "urn:ex/zone-313-temp"
+ },
+ {
+ "@id": "urn:ex/zone-313-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-524-reheat-coil-valve-position",
+ "@id": "urn:ex/vav-532-discharge-air-temp",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
+ "http://data.ashrae.org/standard223#hasAspect": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
+ ],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-527-hot-water-out",
+ "@id": "urn:ex/vav-503-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-527-hot-water-out-connection"
+ "@id": "urn:ex/vav-503-air-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-503-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/zone-106-107-occupancy-sensor",
+ "@id": "urn:ex/zone-206-co2-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/room-106-hvac-domain"
+ "@id": "urn:ex/room-206-hvac-domain"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/zone-106-107-occupancy"
+ "@id": "urn:ex/zone-206-co2-concentration"
}
]
},
{
- "@id": "urn:ex/vav-511-reheat-coil-valve-actuator",
+ "@id": "urn:ex/vav-516-hot-water-in",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-511-reheat-coil-valve"
+ "@id": "urn:ex/vav-516-hot-water-in-connection"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-511-reheat-coil-valve-command"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-526-damper-position",
+ "@id": "urn:ex/vav-503-damper-command",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -1023,46 +965,46 @@
]
},
{
- "@id": "urn:ex/zone-301-occupancy",
+ "@id": "urn:ex/vav-503-reheat-coil-valve-out",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "urn:ex/vav-503-hot-water-out-connection"
}
- ]
- },
- {
- "@id": "urn:ex/room-107",
- "@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/room-107-hvac-domain"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-503-hot-water-out"
}
]
},
{
- "@id": "urn:ex/zone-103-occupancy",
+ "@id": "urn:ex/vav-510-hot-water-in-connection",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-539-damper-in",
+ "@id": "urn:ex/vav-502-reheat-coil-air-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/connection-to-room-101"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -1070,53 +1012,88 @@
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-502-heating-pid-output"
+ },
+ {
+ "@id": "urn:ex/vav-502-more-heat-requests"
+ }
+ ],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-539-air-in"
+ "@id": "urn:ex/vav-502-air-out"
}
]
},
{
- "@id": "urn:ex/vav-512-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/vav-539-more-heat-requests",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/zone-214-temp",
+ "@id": "urn:ex/vav-537-reheat-coil-valve-position",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/zone-111-occupancy-override",
+ "@id": "urn:ex/office-ahu-ea-damper",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "urn:ex/office-ahu-ea-damper-in"
+ },
+ {
+ "@id": "urn:ex/office-ahu-ea-damper-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/office-ahu-ea-damper-command"
+ },
+ {
+ "@id": "urn:ex/office-ahu-ea-damper-position"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasRole": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Exhaust"
}
]
},
{
- "@id": "urn:ex/vav-531-discharge-air-temp",
+ "@id": "urn:ex/room-304",
+ "@type": [
+ "http://data.ashrae.org/standard223#PhysicalSpace"
+ ],
+ "http://data.ashrae.org/standard223#encloses": [
+ {
+ "@id": "urn:ex/room-304-hvac-domain"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-531-discharge-air-flow",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -1127,92 +1104,104 @@
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/zone-210-temp",
+ "@id": "urn:ex/vav-536-reheat-coil-valve-command",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-533-reheat-coil-water-in",
+ "@id": "urn:ex/vav-518-duct-after-damper",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-533-hot-water-in-connection"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-529-reheat-coil",
+ "@type": [
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-529-reheat-coil-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-529-reheat-coil-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-529-reheat-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-529-reheat-coil-water-out"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "urn:ex/vav-533-hot-water-in"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/vav-517-hot-water-out",
+ "@id": "urn:ex/zone-211-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-517-hot-water-out-connection"
+ "@id": "urn:ex/room-211-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/zone-211-temp"
}
]
},
{
- "@id": "urn:ex/vav-536-air-in",
+ "@id": "urn:ex/vav-505-colder-supply-air-requests",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/office-ahu-connection-to-vavs"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-532-damper-in",
+ "@id": "urn:ex/vav-528-reheat-coil-air-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/connection-to-room-302"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -1220,14 +1209,22 @@
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-528-heating-pid-output"
+ },
+ {
+ "@id": "urn:ex/vav-528-more-heat-requests"
+ }
+ ],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-532-air-in"
+ "@id": "urn:ex/vav-528-air-out"
}
]
},
{
- "@id": "urn:ex/vav-521-hot-water-out-connection",
+ "@id": "urn:ex/vav-515-hot-water-in-connection",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Pipe"
@@ -1239,144 +1236,131 @@
]
},
{
- "@id": "urn:ex/zone-111-temp",
+ "@id": "urn:ex/vav-514-discharge-air-flow-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/room-308-out",
+ "@id": "urn:ex/vav-514-discharge-air-temp",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
- ]
- },
- {
- "@id": "urn:ex/zone-303-304-306-occupancy",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-505-reheat-coil-valve-actuator",
+ "@id": "urn:ex/vav-519-hot-water-in",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-505-reheat-coil-valve"
+ "@id": "urn:ex/vav-519-hot-water-in-connection"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-505-reheat-coil-valve-command"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-512-reheat-coil",
+ "@id": "urn:ex/vav-529-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-512-reheat-coil-air-in"
- },
- {
- "@id": "urn:ex/vav-512-reheat-coil-air-out"
- },
- {
- "@id": "urn:ex/vav-512-reheat-coil-water-in"
- },
- {
- "@id": "urn:ex/vav-512-reheat-coil-water-out"
+ "@id": "urn:ex/vav-529-hot-water-out-connection"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-509-reheat-coil-valve-command",
+ "@id": "urn:ex/vav-509-discharge-air-flow",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasAspect": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-521-air-out",
+ "@id": "urn:ex/vav-509-hot-water-in-connection",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/connection-to-room-204-205"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-534-hot-water-in",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-534-hot-water-in-connection"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-521-discharge-air-flow"
- },
- {
- "@id": "urn:ex/vav-521-discharge-air-flow-setpoint"
- },
- {
- "@id": "urn:ex/vav-521-discharge-air-temp"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-521-discharge-air-temp-setpoint"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/room-305-in",
+ "@id": "urn:ex/room-113-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-305"
+ "@id": "urn:ex/connection-to-room-113"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -1386,130 +1370,165 @@
]
},
{
- "@id": "urn:ex/room-112-hvac-domain",
+ "@id": "urn:ex/vav-536-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-112-in"
- },
+ "@id": "urn:ex/vav-536-hot-water-in-connection"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/room-112-out"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "urn:ex/vav-536-hot-water-in"
}
]
},
{
- "@id": "urn:ex/vav-537-more-heat-requests",
+ "@id": "urn:ex/office-ahu-chilled-water-in-connection",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-540-discharge-air-flow-sensor",
+ "@id": "urn:ex/room-201-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-540-air-in"
+ "@id": "urn:ex/room-201-in"
+ },
+ {
+ "@id": "urn:ex/room-201-out"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:ex/vav-540-discharge-air-flow"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-502-more-heat-requests",
+ "@id": "urn:ex/vav-515-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/vav-515-damper"
}
- ]
- },
- {
- "@id": "urn:ex/zone-204-205-window-switch-on-off",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "urn:ex/vav-515-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-512-heating-pid-output",
+ "@id": "urn:ex/vav-516-reheat-coil-air-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/connection-to-room-201"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-516-heating-pid-output"
+ },
+ {
+ "@id": "urn:ex/vav-516-more-heat-requests"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-516-air-out"
}
]
},
{
- "@id": "urn:ex/zone-307-308-temp-sensor",
+ "@id": "urn:ex/vav-511-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/room-307-hvac-domain"
+ "@id": "urn:ex/vav-511-reheat-coil-valve"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/zone-307-308-temp"
+ "@id": "urn:ex/vav-511-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/vav-505-damper",
+ "@id": "urn:ex/vav-508-reheat-coil-air-out",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-505-damper-in"
- },
+ "@id": "urn:ex/connection-to-room-109"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-505-damper-out"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-505-damper-command"
+ "@id": "urn:ex/vav-508-heating-pid-output"
},
{
- "@id": "urn:ex/vav-505-damper-position"
+ "@id": "urn:ex/vav-508-more-heat-requests"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-508-air-out"
}
]
},
{
- "@id": "urn:ex/vav-539-hot-water-out-connection",
+ "@id": "urn:ex/vav-532-damper-actuator",
+ "@type": [
+ "http://data.ashrae.org/standard223#Actuator"
+ ],
+ "http://data.ashrae.org/standard223#actuates": [
+ {
+ "@id": "urn:ex/vav-532-damper"
+ }
+ ],
+ "http://data.ashrae.org/standard223#commandedByProperty": [
+ {
+ "@id": "urn:ex/vav-532-damper-command"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-509-hot-water-out-connection",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Pipe"
@@ -1521,41 +1540,42 @@
]
},
{
- "@id": "urn:ex/vav-507-damper-command",
+ "@id": "urn:ex/office-ahu-sa-fan-power",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/W"
}
]
},
{
- "@id": "urn:ex/zone-305-window-switch-on-off",
+ "@id": "urn:ex/office-ahu-ea-damper-command",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/room-308-in",
+ "@id": "urn:ex/connection-to-room-118",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/connection-to-room-307-308"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -1564,224 +1584,236 @@
]
},
{
- "@id": "urn:ex/vav-538-discharge-air-flow-setpoint",
+ "@id": "urn:ex/vav-516-damper",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:ex/vav-516-damper-in"
+ },
+ {
+ "@id": "urn:ex/vav-516-damper-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:ex/vav-516-damper-command"
+ },
+ {
+ "@id": "urn:ex/vav-516-damper-position"
}
]
},
{
- "@id": "urn:ex/vav-520-reheat-coil-water-out",
+ "@id": "urn:ex/vav-505-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-520-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-505-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-505-hot-water-in"
+ }
]
},
{
- "@id": "urn:ex/zone-112-114-cooling-setpoint",
+ "@id": "urn:ex/vav-529-damper-command",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-519-damper-position",
+ "@id": "urn:ex/zone-210-window-switch-on-off",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/vav-515-reheat-coil-valve-command",
+ "@id": "urn:ex/vav-510-damper",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-510-damper-in"
+ },
+ {
+ "@id": "urn:ex/vav-510-damper-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/vav-510-damper-command"
+ },
+ {
+ "@id": "urn:ex/vav-510-damper-position"
}
]
},
{
- "@id": "urn:ex/vav-519-reheat-coil-valve-command",
+ "@id": "urn:ex/vav-505-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-505-air-in"
}
]
},
{
- "@id": "urn:ex/room-306",
+ "@id": "urn:ex/vav-525-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-306-hvac-domain"
+ "@id": "urn:ex/vav-525-pipe-hot-water-return-before-valve"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/zone-110-window-switch-on-off",
+ "@id": "urn:ex/zone-204-205-occupancy-override",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
]
},
{
- "@id": "urn:ex/vav-502-hot-water-in",
+ "@id": "urn:ex/office-ahu-duct-after-ra-fan",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-502-hot-water-in-connection"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/room-108-hvac-domain",
+ "@id": "urn:ex/vav-527-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/room-108-in"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/room-108-out"
+ "@id": "urn:ex/vav-527-air-in"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "urn:ex/vav-527-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/vav-528-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-527-more-heat-requests",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-528-pipe-hot-water-return-before-valve"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-519",
+ "@id": "urn:ex/vav-505-more-heat-requests",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-519-air-in"
- },
- {
- "@id": "urn:ex/vav-519-air-out"
- },
- {
- "@id": "urn:ex/vav-519-hot-water-in"
- },
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-519-hot-water-out"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-115-window-switch-on-off",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/vav-519-damper"
- },
- {
- "@id": "urn:ex/vav-519-reheat-coil"
- },
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-519-reheat-coil-valve"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/room-304-out",
+ "@id": "urn:ex/vav-513-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/vav-513-reheat-coil-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-513-reheat-coil-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-513-reheat-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-513-reheat-coil-water-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/vav-526-colder-supply-air-requests",
+ "@id": "urn:ex/vav-514-colder-supply-air-requests",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
@@ -1792,75 +1824,72 @@
]
},
{
- "@id": "urn:ex/vav-532-reheat-coil-valve-position",
+ "@id": "urn:ex/vav-518-cooling-pid-output",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-526-reheat-coil-air-in",
+ "@id": "urn:ex/vav-518-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-526-duct-after-damper"
+ "@id": "urn:ex/vav-518-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/room-211-out",
+ "@id": "urn:ex/vav-505-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/connection-to-room-108"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/vav-515-duct-after-damper",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-505-discharge-air-flow"
+ },
+ {
+ "@id": "urn:ex/vav-505-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-505-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-505-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/vav-533-discharge-air-temp",
+ "@id": "urn:ex/zone-301-temp",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
- ],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
"@id": "http://qudt.org/vocab/quantitykind/Temperature"
@@ -1873,99 +1902,108 @@
]
},
{
- "@id": "urn:ex/vav-510-reheat-coil-air-in",
+ "@id": "urn:ex/vav-517-reheat-coil-valve-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-510-duct-after-damper"
+ "@id": "urn:ex/vav-517-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-528-reheat-coil-valve-position",
+ "@id": "urn:ex/vav-507-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-507-air-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/vav-507-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/zone-201-occupancy-override",
+ "@id": "urn:ex/vav-528-more-heat-requests",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-518-discharge-air-flow",
+ "@id": "urn:ex/vav-529-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:ex/vav-529-air-in"
}
]
},
{
- "@id": "urn:ex/vav-504-hot-water-in",
+ "@id": "urn:ex/vav-518-heating-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-504-hot-water-in-connection"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-524-duct-after-damper",
+ "@id": "urn:ex/vav-508-reheat-coil-valve-out",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-508-hot-water-out-connection"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-508-hot-water-out"
}
]
},
{
- "@id": "urn:ex/vav-521-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/vav-532-pipe-hot-water-return-before-valve",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Pipe"
@@ -1977,13 +2015,13 @@
]
},
{
- "@id": "urn:ex/room-214-in",
+ "@id": "urn:ex/vav-539-reheat-coil-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-214"
+ "@id": "urn:ex/vav-539-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -1993,57 +2031,45 @@
]
},
{
- "@id": "urn:ex/vav-503-damper-actuator",
+ "@id": "urn:ex/vav-523-damper-actuator",
"@type": [
"http://data.ashrae.org/standard223#Actuator"
],
"http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/vav-503-damper"
+ "@id": "urn:ex/vav-523-damper"
}
],
"http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/vav-503-damper-command"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-533-hot-water-in-connection",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-523-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-530-heating-pid-output",
+ "@id": "urn:ex/office-ahu-ra-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/office-ahu-duct-after-oa-ra-damper"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-524-damper-out",
+ "@id": "urn:ex/vav-511-reheat-coil-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-524-duct-after-damper"
+ "@id": "urn:ex/connection-to-room-112-114"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -2053,71 +2079,99 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-524-colder-supply-air-requests"
+ "@id": "urn:ex/vav-511-heating-pid-output"
},
{
- "@id": "urn:ex/vav-524-cooling-pid-output"
+ "@id": "urn:ex/vav-511-more-heat-requests"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-511-air-out"
}
]
},
{
- "@id": "urn:ex/vav-526-discharge-air-temp-sensor",
+ "@id": "urn:ex/room-210-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-526-air-out"
+ "@id": "urn:ex/room-210-in"
+ },
+ {
+ "@id": "urn:ex/room-210-out"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:ex/vav-526-discharge-air-temp"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-533-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/vav-526-damper",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-526-damper-in"
+ },
+ {
+ "@id": "urn:ex/vav-526-damper-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-526-damper-command"
+ },
+ {
+ "@id": "urn:ex/vav-526-damper-position"
}
]
},
{
- "@id": "urn:ex/zone-212-temp",
+ "@id": "urn:ex/vav-522-discharge-air-flow",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
+ "http://data.ashrae.org/standard223#hasAspect": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
+ ],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-503-hot-water-out-connection",
+ "@id": "urn:ex/vav-532-discharge-air-flow-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/zone-109-occupancy-override",
+ "@id": "urn:ex/zone-207-occupancy-override",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
@@ -2128,13 +2182,13 @@
]
},
{
- "@id": "urn:ex/vav-528-reheat-coil-water-out",
+ "@id": "urn:ex/vav-531-hot-water-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-528-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-531-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -2144,161 +2198,138 @@
]
},
{
- "@id": "urn:ex/zone-215-occupancy-override",
+ "@id": "urn:ex/office-ahu-moisture-eliminator-out",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "urn:ex/office-ahu-duct-after-moisture-eliminator"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/office-ahu-supply-duct-static-pressure-setpoint",
+ "@id": "urn:ex/room-309-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/IN_H2O"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-514",
+ "@id": "urn:ex/vav-525-air-in",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-514-air-in"
- },
- {
- "@id": "urn:ex/vav-514-air-out"
- },
- {
- "@id": "urn:ex/vav-514-hot-water-in"
- },
- {
- "@id": "urn:ex/vav-514-hot-water-out"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/vav-514-damper"
- },
- {
- "@id": "urn:ex/vav-514-reheat-coil"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-514-reheat-coil-valve"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-510-damper",
+ "@id": "urn:ex/vav-534-reheat-coil-air-out",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-510-damper-in"
- },
+ "@id": "urn:ex/connection-to-room-314"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-510-damper-out"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-510-damper-command"
+ "@id": "urn:ex/vav-534-heating-pid-output"
},
{
- "@id": "urn:ex/vav-510-damper-position"
+ "@id": "urn:ex/vav-534-more-heat-requests"
}
- ]
- },
- {
- "@id": "urn:ex/room-118",
- "@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/room-118-hvac-domain"
+ "@id": "urn:ex/vav-534-air-out"
}
]
},
{
- "@id": "urn:ex/vav-536-hot-water-out",
+ "@id": "urn:ex/office-ahu-ra-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-536-hot-water-out-connection"
+ "@id": "urn:ex/office-ahu-duct-after-ra-fan"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-523-more-heat-requests",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/zone-105-heating-setpoint",
+ "@id": "urn:ex/vav-524-discharge-air-flow-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/office-ahu-duct-after-clg-coil",
+ "@id": "urn:ex/zone-101-co2-sensor",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/room-101-hvac-domain"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:ex/zone-101-co2-concentration"
}
]
},
{
- "@id": "urn:ex/vav-509-damper-out",
+ "@id": "urn:ex/vav-503-reheat-coil-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-509-duct-after-damper"
+ "@id": "urn:ex/connection-to-room-104"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -2308,201 +2339,212 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-509-colder-supply-air-requests"
+ "@id": "urn:ex/vav-503-heating-pid-output"
},
{
- "@id": "urn:ex/vav-509-cooling-pid-output"
+ "@id": "urn:ex/vav-503-more-heat-requests"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-503-air-out"
}
]
},
{
- "@id": "urn:ex/vav-508-reheat-coil",
+ "@id": "urn:ex/vav-522-duct-after-damper",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-508-reheat-coil-air-in"
- },
- {
- "@id": "urn:ex/vav-508-reheat-coil-air-out"
- },
- {
- "@id": "urn:ex/vav-508-reheat-coil-water-in"
- },
- {
- "@id": "urn:ex/vav-508-reheat-coil-water-out"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-533-air-out",
+ "@id": "urn:ex/vav-514-damper",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-305"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:ex/vav-514-damper-in"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-514-damper-out"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-533-discharge-air-flow"
- },
- {
- "@id": "urn:ex/vav-533-discharge-air-flow-setpoint"
+ "@id": "urn:ex/vav-514-damper-command"
},
{
- "@id": "urn:ex/vav-533-discharge-air-temp"
- },
+ "@id": "urn:ex/vav-514-damper-position"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-313-window-switch-on-off",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-533-discharge-air-temp-setpoint"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/vav-530-discharge-air-flow-sensor",
+ "@id": "urn:ex/vav-515-cooling-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-530-air-in"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-530-discharge-air-flow"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/zone-301-window-switch-on-off",
+ "@id": "urn:ex/vav-519-damper-command",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-510-reheat-coil-water-in",
+ "@id": "urn:ex/vav-525-discharge-air-temp",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/vav-510-hot-water-in-connection"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-510-hot-water-in"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-513-reheat-coil-valve-actuator",
+ "@id": "urn:ex/vav-511-reheat-coil-valve-command",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-513-reheat-coil-valve"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-513-reheat-coil-valve-command"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-514-air-in",
+ "@id": "urn:ex/zone-113-occupancy",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ {
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-504-hot-water-out",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-504-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/zone-210-temp-sensor",
+ "@id": "urn:ex/vav-513-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-210-hvac-domain"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-210-temp"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-513-air-in"
}
]
},
{
- "@id": "urn:ex/vav-511-heating-pid-output",
+ "@id": "urn:ex/vav-533-more-heat-requests",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-502-hot-water-in-connection",
+ "@id": "urn:ex/connection-to-room-208-209",
"@type": [
"http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-530-hot-water-out",
+ "@id": "urn:ex/vav-515-hot-water-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-530-hot-water-out-connection"
+ "@id": "urn:ex/vav-515-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -2512,189 +2554,157 @@
]
},
{
- "@id": "urn:ex/vav-509-air-out",
+ "@id": "urn:ex/vav-537-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/connection-to-room-113"
- }
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-537-air-out"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-509-discharge-air-flow"
- },
- {
- "@id": "urn:ex/vav-509-discharge-air-flow-setpoint"
- },
- {
- "@id": "urn:ex/vav-509-discharge-air-temp"
- },
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-509-discharge-air-temp-setpoint"
+ "@id": "urn:ex/vav-537-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/vav-518-reheat-coil-water-in",
+ "@id": "urn:ex/room-106-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-518-hot-water-in-connection"
+ "@id": "urn:ex/connection-to-room-106-107"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-518-hot-water-in"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/zone-103-occupancy-sensor",
+ "@id": "urn:ex/vav-539-heating-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-103-hvac-domain"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/zone-103-occupancy"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/room-103",
+ "@id": "urn:ex/vav-503-hot-water-out-connection",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/room-103-hvac-domain"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-525-reheat-coil-air-out",
+ "@id": "urn:ex/room-112-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-211"
+ "@id": "urn:ex/connection-to-room-112-114"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-525-heating-pid-output"
- },
- {
- "@id": "urn:ex/vav-525-more-heat-requests"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-525-air-out"
- }
]
},
{
- "@id": "urn:ex/zone-215-window-switch-on-off",
+ "@id": "urn:ex/vav-514",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
- }
- ]
- },
- {
- "@id": "urn:ex/zone-201-temp",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "@id": "urn:ex/vav-514-air-in"
+ },
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-514-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-514-hot-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-514-hot-water-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-514-damper"
+ },
+ {
+ "@id": "urn:ex/vav-514-reheat-coil"
+ },
+ {
+ "@id": "urn:ex/vav-514-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/vav-501",
+ "@id": "urn:ex/office-ahu-clg-coil",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ "http://data.ashrae.org/standard223#CoolingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#ChilledWaterCoil"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-501-air-in"
+ "@id": "urn:ex/office-ahu-clg-coil-air-in"
},
{
- "@id": "urn:ex/vav-501-air-out"
+ "@id": "urn:ex/office-ahu-clg-coil-air-out"
},
{
- "@id": "urn:ex/vav-501-hot-water-in"
+ "@id": "urn:ex/office-ahu-clg-coil-water-in"
},
{
- "@id": "urn:ex/vav-501-hot-water-out"
+ "@id": "urn:ex/office-ahu-clg-coil-water-out"
}
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/vav-501-damper"
- },
- {
- "@id": "urn:ex/vav-501-reheat-coil"
- },
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "urn:ex/vav-501-reheat-coil-valve"
+ "@id": "http://data.ashrae.org/standard223#Role-Cooling"
}
]
},
{
- "@id": "urn:ex/vav-516-reheat-coil",
+ "@id": "urn:ex/vav-523-reheat-coil",
"@type": [
"http://data.ashrae.org/standard223#HeatingCoil",
"http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-516-reheat-coil-air-in"
+ "@id": "urn:ex/vav-523-reheat-coil-air-in"
},
{
- "@id": "urn:ex/vav-516-reheat-coil-air-out"
+ "@id": "urn:ex/vav-523-reheat-coil-air-out"
},
{
- "@id": "urn:ex/vav-516-reheat-coil-water-in"
+ "@id": "urn:ex/vav-523-reheat-coil-water-in"
},
{
- "@id": "urn:ex/vav-516-reheat-coil-water-out"
+ "@id": "urn:ex/vav-523-reheat-coil-water-out"
}
],
"http://data.ashrae.org/standard223#hasRole": [
@@ -2704,106 +2714,111 @@
]
},
{
- "@id": "urn:ex/vav-506-reheat-coil-water-out",
+ "@id": "urn:ex/vav-501-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-506-pipe-hot-water-return-before-valve"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-530-reheat-coil-air-out",
+ "@id": "urn:ex/vav-511",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-303-304-306"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:ex/vav-511-air-in"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "@id": "urn:ex/vav-511-air-out"
+ },
{
- "@id": "urn:ex/vav-530-heating-pid-output"
+ "@id": "urn:ex/vav-511-hot-water-in"
},
{
- "@id": "urn:ex/vav-530-more-heat-requests"
+ "@id": "urn:ex/vav-511-hot-water-out"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/vav-530-air-out"
- }
- ]
- },
- {
- "@id": "urn:ex/zone-101-occupancy-override",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "@id": "urn:ex/vav-511-damper"
+ },
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "urn:ex/vav-511-reheat-coil"
+ },
+ {
+ "@id": "urn:ex/vav-511-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/zone-105-temp",
+ "@id": "urn:ex/vav-514-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-514-air-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-514-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/zone-302-occupancy-override",
+ "@id": "urn:ex/zone-106-107",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "urn:ex/room-106-hvac-domain"
+ },
+ {
+ "@id": "urn:ex/room-107-hvac-domain"
}
- ]
- },
- {
- "@id": "urn:ex/vav-520-damper-actuator",
- "@type": [
- "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:ex/vav-520-damper"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-520-damper-command"
+ "@id": "urn:ex/zone-106-107-cooling-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-106-107-heating-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-106-107-occupancy"
+ },
+ {
+ "@id": "urn:ex/zone-106-107-occupancy-override"
+ },
+ {
+ "@id": "urn:ex/zone-106-107-temp"
+ },
+ {
+ "@id": "urn:ex/zone-106-107-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-510-colder-supply-air-requests",
+ "@id": "urn:ex/vav-520-more-heat-requests",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
@@ -2814,37 +2829,40 @@
]
},
{
- "@id": "urn:ex/vav-536-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/room-208",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/room-208-hvac-domain"
}
]
},
{
- "@id": "urn:ex/vav-533-hot-water-out-connection",
+ "@id": "urn:ex/zone-103-cooling-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-523-damper-in",
+ "@id": "urn:ex/vav-513-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-513-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -2852,142 +2870,165 @@
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-523-air-in"
+ "@id": "urn:ex/vav-513-colder-supply-air-requests"
+ },
+ {
+ "@id": "urn:ex/vav-513-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/vav-527-reheat-coil-valve-actuator",
+ "@id": "urn:ex/room-303-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-527-reheat-coil-valve"
+ "@id": "urn:ex/room-303-in"
+ },
+ {
+ "@id": "urn:ex/room-303-out"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:ex/vav-527-reheat-coil-valve-command"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-535-reheat-coil-air-out",
+ "@id": "urn:ex/zone-112-114-occupancy",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/connection-to-room-311"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-523",
+ "@type": [
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "@id": "urn:ex/vav-523-air-in"
+ },
{
- "@id": "urn:ex/vav-535-heating-pid-output"
+ "@id": "urn:ex/vav-523-air-out"
},
{
- "@id": "urn:ex/vav-535-more-heat-requests"
+ "@id": "urn:ex/vav-523-hot-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-523-hot-water-out"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/vav-535-air-out"
+ "@id": "urn:ex/vav-523-damper"
+ },
+ {
+ "@id": "urn:ex/vav-523-reheat-coil"
+ },
+ {
+ "@id": "urn:ex/vav-523-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/vav-506-heating-pid-output",
+ "@id": "urn:ex/vav-511-discharge-air-flow",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
+ "http://data.ashrae.org/standard223#hasAspect": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
+ ],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/zone-102-temp-sensor",
+ "@id": "urn:ex/zone-208-209-occupancy-override",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:ex/room-102-hvac-domain"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/zone-102-temp"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
]
},
{
- "@id": "urn:ex/vav-505-reheat-coil-air-out",
+ "@id": "urn:ex/room-114-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-108"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-505-discharge-air-temp-sensor",
+ "@type": [
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-505-heating-pid-output"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-505-more-heat-requests"
+ "@id": "urn:ex/vav-505-air-out"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-505-air-out"
+ "@id": "urn:ex/vav-505-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/vav-504-damper-command",
+ "@id": "urn:ex/vav-537-cooling-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-510-reheat-coil-water-out",
+ "@id": "urn:ex/vav-512-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-510-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-512-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -2997,213 +3038,173 @@
]
},
{
- "@id": "urn:ex/vav-533-damper-out",
+ "@id": "urn:ex/room-302-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-533-duct-after-damper"
+ "@id": "urn:ex/connection-to-room-302"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-533-colder-supply-air-requests"
- },
- {
- "@id": "urn:ex/vav-533-cooling-pid-output"
- }
]
},
{
- "@id": "urn:ex/vav-512-discharge-air-flow-sensor",
+ "@id": "urn:ex/zone-118-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-512-air-in"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-512-discharge-air-flow"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/zone-203-temp-sensor",
+ "@id": "urn:ex/vav-510-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-203-hvac-domain"
+ "@id": "urn:ex/vav-510-pipe-hot-water-return-before-valve"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-203-temp"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-515-reheat-coil-water-in",
+ "@id": "urn:ex/vav-520-pipe-hot-water-return-before-valve",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-515-hot-water-in-connection"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-515-hot-water-in"
- }
]
},
{
- "@id": "urn:ex/vav-523-hot-water-out",
+ "@id": "urn:ex/zone-202-window-switch-on-off",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-523-hot-water-out-connection"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/vav-514-reheat-coil-water-in",
+ "@id": "urn:ex/room-111-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-514-hot-water-in-connection"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:ex/room-111-in"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/room-111-out"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:ex/vav-514-hot-water-in"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/zone-110",
+ "@id": "urn:ex/vav-530-duct-after-damper",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/room-110-hvac-domain"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-501-heating-pid-output",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/zone-110-cooling-setpoint"
- },
- {
- "@id": "urn:ex/zone-110-heating-setpoint"
- },
- {
- "@id": "urn:ex/zone-110-occupancy"
- },
- {
- "@id": "urn:ex/zone-110-occupancy-override"
- },
- {
- "@id": "urn:ex/zone-110-temp"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/zone-110-window-switch-on-off"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/zone-112-114-occupancy",
+ "@id": "urn:ex/zone-206-occupancy-override",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
]
},
{
- "@id": "urn:ex/vav-524-heating-pid-output",
+ "@id": "urn:ex/vav-520-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/vav-520-reheat-coil-valve"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "urn:ex/vav-520-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/vav-522-reheat-coil",
+ "@id": "urn:ex/room-310-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-522-reheat-coil-air-in"
- },
- {
- "@id": "urn:ex/vav-522-reheat-coil-air-out"
- },
- {
- "@id": "urn:ex/vav-522-reheat-coil-water-in"
+ "@id": "urn:ex/room-310-in"
},
{
- "@id": "urn:ex/vav-522-reheat-coil-water-out"
+ "@id": "urn:ex/room-310-out"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-530-reheat-coil-valve-position",
+ "@id": "urn:ex/vav-538-reheat-coil-valve-command",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -3217,23 +3218,19 @@
]
},
{
- "@id": "urn:ex/vav-537-heating-pid-output",
+ "@id": "urn:ex/vav-528-hot-water-out-connection",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
- {
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-510-reheat-coil-valve-command",
+ "@id": "urn:ex/vav-513-reheat-coil-valve-command",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -3249,240 +3246,180 @@
]
},
{
- "@id": "urn:ex/room-206-in",
+ "@id": "urn:ex/vav-519-reheat-coil-valve-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-206"
+ "@id": "urn:ex/vav-519-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-526-discharge-air-flow-setpoint",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
- {
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-523-discharge-air-flow-setpoint",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:ex/vav-519-hot-water-out"
}
]
},
{
- "@id": "urn:ex/vav-503-damper-position",
+ "@id": "urn:ex/office-ahu-ma-temp",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/room-307-out",
+ "@id": "urn:ex/vav-530-reheat-coil-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/connection-to-room-303-304-306"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/zone-206-temp",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "urn:ex/vav-530-heating-pid-output"
+ },
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-530-more-heat-requests"
}
- ]
- },
- {
- "@id": "urn:ex/vav-540-pipe-hot-water-return-before-valve",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-530-air-out"
}
]
},
{
- "@id": "urn:ex/vav-528-reheat-coil",
+ "@id": "urn:ex/vav-532-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-528-reheat-coil-air-in"
- },
- {
- "@id": "urn:ex/vav-528-reheat-coil-air-out"
- },
- {
- "@id": "urn:ex/vav-528-reheat-coil-water-in"
+ "@id": "urn:ex/vav-532-reheat-coil-valve-in"
},
{
- "@id": "urn:ex/vav-528-reheat-coil-water-out"
- }
- ],
- "http://data.ashrae.org/standard223#hasRole": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-507-hot-water-in",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-507-hot-water-in-connection"
+ "@id": "urn:ex/vav-532-reheat-coil-valve-out"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
}
- ]
- },
- {
- "@id": "urn:ex/vav-509-duct-after-damper",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-532-reheat-coil-valve-command"
+ },
+ {
+ "@id": "urn:ex/vav-532-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/room-206-out",
+ "@id": "urn:ex/vav-522-reheat-coil-water-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/vav-522-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-535-hot-water-in",
+ "@id": "urn:ex/vav-533-damper-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-535-hot-water-in-connection"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-533-air-in"
}
]
},
{
- "@id": "urn:ex/vav-539-reheat-coil-water-out",
+ "@id": "urn:ex/room-112-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-539-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/room-112-in"
+ },
+ {
+ "@id": "urn:ex/room-112-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-509-reheat-coil-valve-actuator",
+ "@id": "urn:ex/vav-520-hot-water-in",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-509-reheat-coil-valve"
+ "@id": "urn:ex/vav-520-hot-water-in-connection"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-509-reheat-coil-valve-command"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/zone-206",
+ "@id": "urn:ex/zone-302",
"@type": [
"http://data.ashrae.org/standard223#Zone",
"http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
"http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/room-206-hvac-domain"
+ "@id": "urn:ex/room-302-hvac-domain"
}
],
"http://data.ashrae.org/standard223#hasDomain": [
@@ -3492,167 +3429,146 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/zone-206-co2-concentration"
+ "@id": "urn:ex/zone-302-co2-concentration"
},
{
- "@id": "urn:ex/zone-206-co2-concentration-setpoint"
+ "@id": "urn:ex/zone-302-co2-concentration-setpoint"
},
{
- "@id": "urn:ex/zone-206-cooling-setpoint"
+ "@id": "urn:ex/zone-302-cooling-setpoint"
},
{
- "@id": "urn:ex/zone-206-heating-setpoint"
+ "@id": "urn:ex/zone-302-heating-setpoint"
},
{
- "@id": "urn:ex/zone-206-occupancy"
+ "@id": "urn:ex/zone-302-occupancy"
},
{
- "@id": "urn:ex/zone-206-occupancy-override"
+ "@id": "urn:ex/zone-302-occupancy-override"
},
{
- "@id": "urn:ex/zone-206-temp"
+ "@id": "urn:ex/zone-302-temp"
},
{
- "@id": "urn:ex/zone-206-window-switch-on-off"
+ "@id": "urn:ex/zone-302-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-532-reheat-coil-valve-command",
+ "@id": "urn:ex/room-303-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-524-hot-water-in",
+ "@id": "urn:ex/vav-503-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-524-hot-water-in-connection"
+ "@id": "urn:ex/vav-503-reheat-coil-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-503-reheat-coil-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-503-reheat-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-503-reheat-coil-water-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/zone-213-temp-sensor",
+ "@id": "urn:ex/vav-504-heating-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-213-hvac-domain"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/zone-213-temp"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-539-discharge-air-temp-sensor",
+ "@id": "urn:ex/vav-522-more-heat-requests",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:ex/vav-539-air-out"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-539-discharge-air-temp"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-539-hot-water-out",
+ "@id": "urn:ex/zone-111-window-switch-on-off",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-539-hot-water-out-connection"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/zone-213",
+ "@id": "urn:ex/vav-502-more-heat-requests",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
- ],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/room-213-hvac-domain"
- }
- ],
- "http://data.ashrae.org/standard223#hasDomain": [
- {
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/zone-213-cooling-setpoint"
- },
- {
- "@id": "urn:ex/zone-213-heating-setpoint"
- },
- {
- "@id": "urn:ex/zone-213-occupancy"
- },
- {
- "@id": "urn:ex/zone-213-occupancy-override"
- },
- {
- "@id": "urn:ex/zone-213-temp"
- },
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/zone-213-window-switch-on-off"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/zone-202-window-switch-on-off",
+ "@id": "urn:ex/vav-511-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "urn:ex/vav-511-damper"
+ }
+ ],
+ "http://data.ashrae.org/standard223#commandedByProperty": [
+ {
+ "@id": "urn:ex/vav-511-damper-command"
}
]
},
{
- "@id": "urn:ex/room-114-out",
+ "@id": "urn:ex/vav-536-air-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -3662,51 +3578,60 @@
]
},
{
- "@id": "urn:ex/vav-518-hot-water-in",
+ "@id": "urn:ex/office-ahu-connection-from-rooms",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-518-hot-water-in-connection"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-530-more-heat-requests",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-529-discharge-air-flow",
+ "@id": "urn:ex/vav-530-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ "@id": "urn:ex/vav-530-reheat-coil-valve-in"
+ },
+ {
+ "@id": "urn:ex/vav-530-reheat-coil-valve-out"
}
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:ex/vav-530-reheat-coil-valve-command"
+ },
+ {
+ "@id": "urn:ex/vav-530-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-504-discharge-air-temp",
+ "@id": "urn:ex/vav-512-discharge-air-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -3720,7 +3645,7 @@
]
},
{
- "@id": "urn:ex/vav-538-discharge-air-temp-setpoint",
+ "@id": "urn:ex/vav-502-discharge-air-temp-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -3736,112 +3661,128 @@
]
},
{
- "@id": "urn:ex/office-ahu-ea-out-connection",
+ "@id": "urn:ex/vav-509-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-509-damper"
+ }
+ ],
+ "http://data.ashrae.org/standard223#commandedByProperty": [
+ {
+ "@id": "urn:ex/vav-509-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-537-reheat-coil-air-in",
+ "@id": "urn:ex/vav-513-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-537-duct-after-damper"
+ "@id": "urn:ex/vav-513-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-514-reheat-coil-valve-in",
+ "@id": "urn:ex/room-303",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-514-pipe-hot-water-return-before-valve"
- }
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/room-303-hvac-domain"
}
]
},
{
- "@id": "urn:ex/vav-528-discharge-air-temp-sensor",
+ "@id": "urn:ex/vav-540-heating-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-528-air-out"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-528-discharge-air-temp"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/room-208-in",
+ "@id": "urn:ex/vav-531-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-208-209"
+ "@id": "urn:ex/vav-531-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-531-colder-supply-air-requests"
+ },
+ {
+ "@id": "urn:ex/vav-531-cooling-pid-output"
+ }
]
},
{
- "@id": "urn:ex/connection-to-room-208-209",
+ "@id": "urn:ex/vav-526-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-526-reheat-coil-valve"
+ }
+ ],
+ "http://data.ashrae.org/standard223#commandedByProperty": [
+ {
+ "@id": "urn:ex/vav-526-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/zone-203-occupancy",
+ "@id": "urn:ex/zone-204-205-temp",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-517-air-out",
+ "@id": "urn:ex/vav-506-damper-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-203"
+ "@id": "urn:ex/vav-506-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -3851,27 +3792,21 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-517-discharge-air-flow"
- },
- {
- "@id": "urn:ex/vav-517-discharge-air-flow-setpoint"
- },
- {
- "@id": "urn:ex/vav-517-discharge-air-temp"
+ "@id": "urn:ex/vav-506-colder-supply-air-requests"
},
{
- "@id": "urn:ex/vav-517-discharge-air-temp-setpoint"
+ "@id": "urn:ex/vav-506-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/vav-518-damper-in",
+ "@id": "urn:ex/vav-538-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-538-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -3879,420 +3814,437 @@
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-518-air-in"
+ "@id": "urn:ex/vav-538-colder-supply-air-requests"
+ },
+ {
+ "@id": "urn:ex/vav-538-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/vav-517-discharge-air-flow",
+ "@id": "urn:ex/vav-510-reheat-coil-air-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ "@id": "urn:ex/connection-to-room-111"
}
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:ex/vav-510-heating-pid-output"
+ },
+ {
+ "@id": "urn:ex/vav-510-more-heat-requests"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-510-air-out"
}
]
},
{
- "@id": "urn:ex/room-110",
+ "@id": "urn:ex/vav-518-colder-supply-air-requests",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/room-110-hvac-domain"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-529-reheat-coil-air-out",
+ "@id": "urn:ex/zone-309-310-occupancy-override",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/connection-to-room-303-304-306"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-529-heating-pid-output"
- },
- {
- "@id": "urn:ex/vav-529-more-heat-requests"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-529-air-out"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
]
},
{
- "@id": "urn:ex/vav-509-reheat-coil-valve-position",
+ "@id": "urn:ex/vav-517-colder-supply-air-requests",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/connection-to-room-108",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-503-reheat-coil-valve-position",
+ "@id": "urn:ex/zone-101-building-static-pressure",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/IN_H2O"
}
]
},
{
- "@id": "urn:ex/vav-536-reheat-coil-valve",
+ "@id": "urn:ex/vav-520-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-536-reheat-coil-valve-in"
+ "@id": "urn:ex/vav-520-reheat-coil-air-in"
},
{
- "@id": "urn:ex/vav-536-reheat-coil-valve-out"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:ex/vav-520-reheat-coil-air-out"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "urn:ex/vav-520-reheat-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-520-reheat-coil-water-out"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-536-reheat-coil-valve-command"
- },
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "urn:ex/vav-536-reheat-coil-valve-position"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/vav-513-hot-water-in-connection",
+ "@id": "urn:ex/vav-537-discharge-air-temp",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-528-air-in",
+ "@id": "urn:ex/room-212-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/room-212-in"
+ },
+ {
+ "@id": "urn:ex/room-212-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-507-reheat-coil-water-out",
+ "@id": "urn:ex/vav-530-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/vav-507-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-530-reheat-coil-valve"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-530-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/vav-527-damper-out",
+ "@id": "urn:ex/zone-214-temp",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-527-duct-after-damper"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/room-308",
+ "@type": [
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-527-colder-supply-air-requests"
- },
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "urn:ex/vav-527-cooling-pid-output"
+ "@id": "urn:ex/room-308-hvac-domain"
}
]
},
{
- "@id": "urn:ex/zone-204-205-cooling-setpoint",
+ "@id": "urn:ex/vav-533-heating-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-516-hot-water-in",
+ "@id": "urn:ex/vav-531-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/vav-516-hot-water-in-connection"
+ "@id": "urn:ex/vav-531-damper"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-531-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-523-damper-out",
+ "@id": "urn:ex/vav-506-damper",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-523-duct-after-damper"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:ex/vav-506-damper-in"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-506-damper-out"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-523-colder-supply-air-requests"
+ "@id": "urn:ex/vav-506-damper-command"
},
{
- "@id": "urn:ex/vav-523-cooling-pid-output"
+ "@id": "urn:ex/vav-506-damper-position"
}
]
},
{
- "@id": "urn:ex/zone-303-304-306-cooling-setpoint",
+ "@id": "urn:ex/vav-508-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-508-reheat-coil-valve"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-508-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/vav-509-discharge-air-temp-setpoint",
+ "@id": "urn:ex/room-116-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/connection-to-room-116-117"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/office-ahu-sa-temp-sensor",
+ "@id": "urn:ex/vav-532-damper-command",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/office-ahu-sa-out"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/office-ahu-sa-temp"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/zone-307-308-occupancy",
+ "@id": "urn:ex/room-213",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "urn:ex/room-213-hvac-domain"
}
]
},
{
- "@id": "urn:ex/vav-504-air-in",
+ "@id": "urn:ex/vav-531-heating-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/zone-313-temp-sensor",
+ "@id": "urn:ex/vav-540-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-313-hvac-domain"
+ "@id": "urn:ex/vav-540-hot-water-in-connection"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-313-temp"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-540-hot-water-in"
}
]
},
{
- "@id": "urn:ex/room-204-in",
+ "@id": "urn:ex/vav-515-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/connection-to-room-204-205"
+ "@id": "urn:ex/vav-515-air-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-515-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/vav-518-damper-actuator",
+ "@id": "urn:ex/vav-512-more-heat-requests",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
- ],
- "http://data.ashrae.org/standard223#actuates": [
- {
- "@id": "urn:ex/vav-518-damper"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-518-damper-command"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-502-reheat-coil-water-out",
+ "@id": "urn:ex/vav-539-reheat-coil-valve-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-502-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-539-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-539-hot-water-out"
+ }
]
},
{
- "@id": "urn:ex/vav-534-hot-water-in",
+ "@id": "urn:ex/vav-537-damper-command",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-534-hot-water-in-connection"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-519-reheat-coil-water-out",
+ "@id": "urn:ex/vav-515-reheat-coil-water-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-519-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-515-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -4302,218 +4254,199 @@
]
},
{
- "@id": "urn:ex/zone-313-heating-setpoint",
+ "@id": "urn:ex/vav-533-reheat-coil-air-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/connection-to-room-305"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-533-heating-pid-output"
+ },
+ {
+ "@id": "urn:ex/vav-533-more-heat-requests"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-533-air-out"
}
]
},
{
- "@id": "urn:ex/room-203",
+ "@id": "urn:ex/vav-521-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/room-203-hvac-domain"
+ "@id": "urn:ex/vav-521-air-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:ex/vav-521-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/vav-511-cooling-pid-output",
+ "@id": "urn:ex/vav-507-discharge-air-temp",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
+ "http://data.ashrae.org/standard223#hasAspect": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
+ ],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-504-reheat-coil-valve",
+ "@id": "urn:ex/vav-521-reheat-coil-valve-out",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-504-reheat-coil-valve-in"
- },
- {
- "@id": "urn:ex/vav-504-reheat-coil-valve-out"
+ "@id": "urn:ex/vav-521-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-504-reheat-coil-valve-command"
- },
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-504-reheat-coil-valve-position"
+ "@id": "urn:ex/vav-521-hot-water-out"
}
]
},
{
- "@id": "urn:ex/vav-523-reheat-coil-valve-command",
+ "@id": "urn:ex/office-ahu-htg-coil-air-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/office-ahu-duct-after-air-filter"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/office-ahu-ma-temp-sensor",
+ "@id": "urn:ex/vav-510-discharge-air-flow-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/office-ahu-air-filter-in"
+ "@id": "urn:ex/vav-510-air-in"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/office-ahu-ma-temp"
+ "@id": "urn:ex/vav-510-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/vav-528-reheat-coil-air-out",
+ "@id": "urn:ex/vav-531-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/connection-to-room-302"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-528-heating-pid-output"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-528-more-heat-requests"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-528-air-out"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-503-hot-water-in",
+ "@id": "urn:ex/zone-103-occupancy-sensor",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-503-hot-water-in-connection"
+ "@id": "urn:ex/room-103-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/zone-103-occupancy"
}
]
},
{
- "@id": "urn:ex/zone-302-co2-concentration-setpoint",
+ "@id": "urn:ex/vav-525-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://data.ashrae.org/standard223#ofSubstance": [
- {
- "@id": "http://data.ashrae.org/standard223#Substance-CO2"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/MoleFraction"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PPM"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-534-discharge-air-flow",
+ "@id": "urn:ex/zone-108-temp",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
- ],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-526-hot-water-in-connection",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/room-301-hvac-domain",
+ "@id": "urn:ex/room-118-hvac-domain",
"@type": [
"http://data.ashrae.org/standard223#DomainSpace"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-301-in"
+ "@id": "urn:ex/room-118-in"
},
{
- "@id": "urn:ex/room-301-out"
+ "@id": "urn:ex/room-118-out"
}
],
"http://data.ashrae.org/standard223#hasDomain": [
@@ -4523,202 +4456,113 @@
]
},
{
- "@id": "urn:ex/zone-113-occupancy",
+ "@id": "urn:ex/vav-532-damper",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "urn:ex/vav-532-damper-in"
+ },
+ {
+ "@id": "urn:ex/vav-532-damper-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-532-damper-command"
+ },
+ {
+ "@id": "urn:ex/vav-532-damper-position"
}
]
},
{
- "@id": "urn:ex/vav-514-reheat-coil-valve-out",
+ "@id": "urn:ex/vav-521-hot-water-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-514-hot-water-out-connection"
+ "@id": "urn:ex/vav-521-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-514-hot-water-out"
- }
]
},
{
- "@id": "urn:ex/vav-518-damper-command",
+ "@id": "urn:ex/vav-523-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-523-hot-water-out-connection"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-531-air-out",
+ "@id": "urn:ex/vav-539-hot-water-out-connection",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/connection-to-room-307-308"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-531-discharge-air-flow"
- },
- {
- "@id": "urn:ex/vav-531-discharge-air-flow-setpoint"
- },
- {
- "@id": "urn:ex/vav-531-discharge-air-temp"
- },
- {
- "@id": "urn:ex/vav-531-discharge-air-temp-setpoint"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-523-damper",
- "@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-523-damper-in"
- },
- {
- "@id": "urn:ex/vav-523-damper-out"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-523-damper-command"
- },
- {
- "@id": "urn:ex/vav-523-damper-position"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-507-air-out",
+ "@id": "urn:ex/vav-524",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-110"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-507-discharge-air-flow"
+ "@id": "urn:ex/vav-524-air-in"
},
{
- "@id": "urn:ex/vav-507-discharge-air-flow-setpoint"
+ "@id": "urn:ex/vav-524-air-out"
},
{
- "@id": "urn:ex/vav-507-discharge-air-temp"
+ "@id": "urn:ex/vav-524-hot-water-in"
},
{
- "@id": "urn:ex/vav-507-discharge-air-temp-setpoint"
+ "@id": "urn:ex/vav-524-hot-water-out"
}
- ]
- },
- {
- "@id": "urn:ex/zone-211",
- "@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
"http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/room-211-hvac-domain"
- }
- ],
- "http://data.ashrae.org/standard223#hasDomain": [
- {
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/zone-211-cooling-setpoint"
- },
- {
- "@id": "urn:ex/zone-211-heating-setpoint"
- },
- {
- "@id": "urn:ex/zone-211-occupancy"
- },
- {
- "@id": "urn:ex/zone-211-occupancy-override"
+ "@id": "urn:ex/vav-524-damper"
},
{
- "@id": "urn:ex/zone-211-temp"
+ "@id": "urn:ex/vav-524-reheat-coil"
},
{
- "@id": "urn:ex/zone-211-window-switch-on-off"
+ "@id": "urn:ex/vav-524-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/vav-522-damper-out",
+ "@id": "urn:ex/vav-527-air-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-522-duct-after-damper"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-522-colder-supply-air-requests"
- },
- {
- "@id": "urn:ex/vav-522-cooling-pid-output"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
- ]
- },
- {
- "@id": "urn:ex/vav-523-duct-after-damper",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -4727,246 +4571,163 @@
]
},
{
- "@id": "urn:ex/office-ahu-ra-fan-speed-status",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
- {
- "@id": "http://qudt.org/vocab/unit/PERCENT"
- }
- ]
- },
- {
- "@id": "urn:ex/zone-312-temp-sensor",
- "@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:ex/room-312-hvac-domain"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
- {
- "@id": "urn:ex/zone-312-temp"
- }
- ]
- },
- {
- "@id": "urn:ex/zone-212-occupancy",
+ "@id": "urn:ex/vav-531-colder-supply-air-requests",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/zone-111",
+ "@id": "urn:ex/office-ahu-sa-flow",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/room-111-hvac-domain"
+ "@id": "http://data.ashrae.org/standard223#Role-Supply"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/zone-111-cooling-setpoint"
- },
- {
- "@id": "urn:ex/zone-111-heating-setpoint"
- },
- {
- "@id": "urn:ex/zone-111-occupancy"
- },
- {
- "@id": "urn:ex/zone-111-occupancy-override"
- },
- {
- "@id": "urn:ex/zone-111-temp"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/zone-111-window-switch-on-off"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-518-reheat-coil-valve-command",
+ "@id": "urn:ex/vav-513-discharge-air-flow-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-514-duct-after-damper",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-536-colder-supply-air-requests",
+ "@id": "urn:ex/zone-113-window-switch-on-off",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/zone-312-occupancy-sensor",
+ "@id": "urn:ex/vav-508-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-312-hvac-domain"
+ "@id": "urn:ex/vav-508-hot-water-out-connection"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-312-occupancy"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-506-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/vav-503-discharge-air-temp",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
- ]
- },
- {
- "@id": "urn:ex/vav-510-reheat-coil-valve-in",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-510-pipe-hot-water-return-before-valve"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-517-hot-water-in-connection",
+ "@id": "urn:ex/zone-118-window-switch-on-off",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/vav-518-reheat-coil-valve-in",
+ "@id": "urn:ex/zone-204-205-window-switch-on-off",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-518-pipe-hot-water-return-before-valve"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/vav-521-reheat-coil-valve-in",
+ "@id": "urn:ex/office-ahu-increased-air-pressure-requests",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-521-pipe-hot-water-return-before-valve"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-518-discharge-air-temp-sensor",
+ "@id": "urn:ex/vav-511-colder-supply-air-requests",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:ex/vav-518-air-out"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-518-discharge-air-temp"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-513-air-in",
+ "@id": "urn:ex/vav-509-hot-water-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-509-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/room-109-out",
+ "@id": "urn:ex/room-304-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -4982,93 +4743,61 @@
]
},
{
- "@id": "urn:ex/office-ahu-chilled-water-in",
+ "@id": "urn:ex/vav-533-reheat-coil-valve-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-chilled-water-in-connection"
+ "@id": "urn:ex/vav-533-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
- ]
- },
- {
- "@id": "urn:ex/vav-521-reheat-coil-valve-actuator",
- "@type": [
- "http://data.ashrae.org/standard223#Actuator"
- ],
- "http://data.ashrae.org/standard223#actuates": [
- {
- "@id": "urn:ex/vav-521-reheat-coil-valve"
- }
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-521-reheat-coil-valve-command"
+ "@id": "urn:ex/vav-533-hot-water-out"
}
]
},
{
- "@id": "urn:ex/vav-507",
+ "@id": "urn:ex/vav-502-hot-water-in-connection",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-507-air-in"
- },
- {
- "@id": "urn:ex/vav-507-air-out"
- },
- {
- "@id": "urn:ex/vav-507-hot-water-in"
- },
- {
- "@id": "urn:ex/vav-507-hot-water-out"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/vav-507-damper"
- },
- {
- "@id": "urn:ex/vav-507-reheat-coil"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-507-reheat-coil-valve"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-525-hot-water-out-connection",
+ "@id": "urn:ex/zone-113-occupancy-override",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
]
},
{
- "@id": "urn:ex/vav-501-reheat-coil-valve",
+ "@id": "urn:ex/office-ahu-htg-coil-valve",
"@type": [
"http://data.ashrae.org/standard223#Valve",
"http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-501-reheat-coil-valve-in"
+ "@id": "urn:ex/office-ahu-htg-coil-valve-in"
},
{
- "@id": "urn:ex/vav-501-reheat-coil-valve-out"
+ "@id": "urn:ex/office-ahu-htg-coil-valve-out"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -5078,63 +4807,64 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-501-reheat-coil-valve-command"
+ "@id": "urn:ex/office-ahu-htg-coil-valve-command"
},
{
- "@id": "urn:ex/vav-501-reheat-coil-valve-position"
+ "@id": "urn:ex/office-ahu-htg-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/zone-203-cooling-setpoint",
+ "@id": "urn:ex/vav-518-damper-command",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-528-discharge-air-flow-sensor",
+ "@id": "urn:ex/vav-505-hot-water-out-connection",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:ex/vav-528-air-in"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-528-discharge-air-flow"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/zone-111-occupancy-sensor",
+ "@id": "urn:ex/vav-516-discharge-air-flow",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/room-111-hvac-domain"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/zone-111-occupancy"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/zone-302-heating-setpoint",
+ "@id": "urn:ex/zone-313-cooling-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -5150,67 +4880,101 @@
]
},
{
- "@id": "urn:ex/connection-to-room-211",
+ "@id": "urn:ex/office-ahu",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#AirHandlingUnit"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-519-reheat-coil-valve-position",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "@id": "urn:ex/office-ahu-chilled-water-in"
+ },
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/office-ahu-chilled-water-out"
+ },
+ {
+ "@id": "urn:ex/office-ahu-ea-out"
+ },
+ {
+ "@id": "urn:ex/office-ahu-hot-water-in"
+ },
+ {
+ "@id": "urn:ex/office-ahu-hot-water-out"
+ },
+ {
+ "@id": "urn:ex/office-ahu-oa-in"
+ },
+ {
+ "@id": "urn:ex/office-ahu-ra-in"
+ },
+ {
+ "@id": "urn:ex/office-ahu-sa-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/office-ahu-air-filter"
+ },
+ {
+ "@id": "urn:ex/office-ahu-clg-coil"
+ },
+ {
+ "@id": "urn:ex/office-ahu-clg-coil-valve"
+ },
+ {
+ "@id": "urn:ex/office-ahu-ea-damper"
+ },
+ {
+ "@id": "urn:ex/office-ahu-htg-coil"
+ },
+ {
+ "@id": "urn:ex/office-ahu-htg-coil-valve"
+ },
+ {
+ "@id": "urn:ex/office-ahu-moisture-eliminator"
+ },
+ {
+ "@id": "urn:ex/office-ahu-oa-damper"
+ },
+ {
+ "@id": "urn:ex/office-ahu-ra-damper"
+ },
+ {
+ "@id": "urn:ex/office-ahu-ra-fan"
+ },
+ {
+ "@id": "urn:ex/office-ahu-sa-fan"
}
]
},
{
- "@id": "urn:ex/vav-502-damper-position",
+ "@id": "urn:ex/room-115",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/room-115-hvac-domain"
}
]
},
{
- "@id": "urn:ex/vav-514-reheat-coil-valve-position",
+ "@id": "urn:ex/vav-538-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-538-air-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/vav-538-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/vav-509-cooling-pid-output",
+ "@id": "urn:ex/vav-531-cooling-pid-output",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -5226,155 +4990,82 @@
]
},
{
- "@id": "urn:ex/vav-511-damper-out",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-511-duct-after-damper"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-511-colder-supply-air-requests"
- },
- {
- "@id": "urn:ex/vav-511-cooling-pid-output"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-515-damper-actuator",
- "@type": [
- "http://data.ashrae.org/standard223#Actuator"
- ],
- "http://data.ashrae.org/standard223#actuates": [
- {
- "@id": "urn:ex/vav-515-damper"
- }
- ],
- "http://data.ashrae.org/standard223#commandedByProperty": [
- {
- "@id": "urn:ex/vav-515-damper-command"
- }
- ]
- },
- {
- "@id": "urn:ex/connection-to-room-109",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ]
- },
- {
- "@id": "urn:ex/room-110-hvac-domain",
+ "@id": "urn:ex/vav-537-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-110-in"
- },
- {
- "@id": "urn:ex/room-110-out"
- }
- ],
- "http://data.ashrae.org/standard223#hasDomain": [
- {
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "urn:ex/vav-537-hot-water-in-connection"
}
- ]
- },
- {
- "@id": "urn:ex/vav-506-hot-water-in-connection",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
- ]
- },
- {
- "@id": "urn:ex/vav-524-hot-water-out-connection",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-537-hot-water-in"
}
]
},
{
- "@id": "urn:ex/room-304-hvac-domain",
+ "@id": "urn:ex/office-ahu-oa-in",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-304-in"
- },
- {
- "@id": "urn:ex/room-304-out"
+ "@id": "urn:ex/office-ahu-oa-in-connection"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/zone-214-temp-sensor",
+ "@id": "urn:ex/zone-210-temp-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/room-214-hvac-domain"
+ "@id": "urn:ex/room-210-hvac-domain"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/zone-214-temp"
+ "@id": "urn:ex/zone-210-temp"
}
]
},
{
- "@id": "urn:ex/connection-to-room-202",
+ "@id": "urn:ex/zone-307-308-cooling-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-530-air-in",
+ "@id": "urn:ex/vav-510-reheat-coil-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-510-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -5383,33 +5074,6 @@
}
]
},
- {
- "@id": "urn:ex/vav-516-reheat-coil-valve-actuator",
- "@type": [
- "http://data.ashrae.org/standard223#Actuator"
- ],
- "http://data.ashrae.org/standard223#actuates": [
- {
- "@id": "urn:ex/vav-516-reheat-coil-valve"
- }
- ],
- "http://data.ashrae.org/standard223#commandedByProperty": [
- {
- "@id": "urn:ex/vav-516-reheat-coil-valve-command"
- }
- ]
- },
- {
- "@id": "urn:ex/zone-116-117-window-switch-on-off",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
- }
- ]
- },
{
"@id": "urn:ex/vav-538-damper",
"@type": [
@@ -5434,90 +5098,74 @@
]
},
{
- "@id": "urn:ex/vav-528-duct-after-damper",
+ "@id": "urn:ex/zone-311-occupancy",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
]
},
{
- "@id": "urn:ex/zone-113-temp-sensor",
+ "@id": "urn:ex/vav-520-reheat-coil-air-out",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-113-hvac-domain"
+ "@id": "urn:ex/connection-to-room-207"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-113-temp"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/zone-212-occupancy-override",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-519-hot-water-out",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
+ "@id": "urn:ex/vav-520-heating-pid-output"
+ },
{
- "@id": "urn:ex/vav-519-hot-water-out-connection"
+ "@id": "urn:ex/vav-520-more-heat-requests"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-520-air-out"
}
]
},
{
- "@id": "urn:ex/room-207-in",
+ "@id": "urn:ex/vav-510-hot-water-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-207"
+ "@id": "urn:ex/vav-510-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/office-ahu-duct-after-htg-coil",
+ "@id": "urn:ex/zone-305-window-switch-on-off",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/zone-101-heating-setpoint",
+ "@id": "urn:ex/zone-206-heating-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -5533,94 +5181,89 @@
]
},
{
- "@id": "urn:ex/zone-101",
+ "@id": "urn:ex/vav-504-air-out",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-101-hvac-domain"
+ "@id": "urn:ex/connection-to-room-105"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/zone-101-building-static-pressure"
- },
- {
- "@id": "urn:ex/zone-101-building-static-pressure-setpoint"
- },
- {
- "@id": "urn:ex/zone-101-co2-concentration"
- },
- {
- "@id": "urn:ex/zone-101-co2-concentration-setpoint"
- },
- {
- "@id": "urn:ex/zone-101-cooling-setpoint"
- },
- {
- "@id": "urn:ex/zone-101-heating-setpoint"
+ "@id": "urn:ex/vav-504-discharge-air-flow"
},
{
- "@id": "urn:ex/zone-101-occupancy"
+ "@id": "urn:ex/vav-504-discharge-air-flow-setpoint"
},
{
- "@id": "urn:ex/zone-101-occupancy-override"
+ "@id": "urn:ex/vav-504-discharge-air-temp"
},
{
- "@id": "urn:ex/zone-101-temp"
- },
+ "@id": "urn:ex/vav-504-discharge-air-temp-setpoint"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-210-occupancy-override",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/zone-101-window-switch-on-off"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
]
},
{
- "@id": "urn:ex/vav-537-reheat-coil-valve-actuator",
+ "@id": "urn:ex/vav-527-reheat-coil-air-in",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-537-reheat-coil-valve"
+ "@id": "urn:ex/vav-527-duct-after-damper"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-537-reheat-coil-valve-command"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-512-discharge-air-temp-sensor",
+ "@id": "urn:ex/room-213-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-512-air-out"
+ "@id": "urn:ex/room-213-in"
+ },
+ {
+ "@id": "urn:ex/room-213-out"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:ex/vav-512-discharge-air-temp"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-525-reheat-coil-water-out",
+ "@id": "urn:ex/vav-508-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-525-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-508-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -5630,45 +5273,45 @@
]
},
{
- "@id": "urn:ex/vav-535-reheat-coil-valve-command",
+ "@id": "urn:ex/zone-212-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/room-212-hvac-domain"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/zone-212-temp"
}
]
},
{
- "@id": "urn:ex/zone-313-temp",
+ "@id": "urn:ex/vav-525-heating-pid-output",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-524-reheat-coil-air-in",
+ "@id": "urn:ex/office-ahu-htg-coil-air-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-524-duct-after-damper"
+ "@id": "urn:ex/office-ahu-duct-after-htg-coil"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -5678,133 +5321,126 @@
]
},
{
- "@id": "urn:ex/vav-504-reheat-coil-valve-command",
+ "@id": "urn:ex/office-ahu-duct-after-oa-ra-damper",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-524-cooling-pid-output",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-531-discharge-air-temp-sensor",
+ "@id": "urn:ex/office-ahu-ra-fan-start-cmd",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:ex/vav-531-air-out"
- }
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-531-discharge-air-temp"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/vav-533-damper-actuator",
+ "@id": "urn:ex/office-ahu-ra-fan-speed-cmd",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-533-damper"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-533-damper-command"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-520-air-in",
+ "@id": "urn:ex/office-ahu-warmer-supply-air-requests",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/office-ahu-connection-to-vavs"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/office-ahu-htg-coil-water-out",
+ "@id": "urn:ex/vav-528-discharge-air-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/office-ahu-pipe-hot-water-return-before-valve"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-526-air-out",
+ "@id": "urn:ex/vav-517-discharge-air-temp",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/connection-to-room-212"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-526-discharge-air-flow"
- },
- {
- "@id": "urn:ex/vav-526-discharge-air-flow-setpoint"
- },
- {
- "@id": "urn:ex/vav-526-discharge-air-temp"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-526-discharge-air-temp-setpoint"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/zone-108-occupancy-sensor",
+ "@id": "urn:ex/room-103-out",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-108-hvac-domain"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-108-occupancy"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-520-discharge-air-temp-setpoint",
+ "@id": "urn:ex/zone-108-cooling-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -5820,68 +5456,61 @@
]
},
{
- "@id": "urn:ex/vav-502-reheat-coil-valve",
+ "@id": "urn:ex/room-308-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-502-reheat-coil-valve-in"
+ "@id": "urn:ex/room-308-in"
},
{
- "@id": "urn:ex/vav-502-reheat-coil-valve-out"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "urn:ex/room-308-out"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-502-reheat-coil-valve-command"
- },
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:ex/vav-502-reheat-coil-valve-position"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-504-air-out",
+ "@id": "urn:ex/vav-502-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/connection-to-room-105"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/office-ahu-chilled-water-out-connection",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-504-discharge-air-flow"
- },
- {
- "@id": "urn:ex/vav-504-discharge-air-flow-setpoint"
- },
- {
- "@id": "urn:ex/vav-504-discharge-air-temp"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-504-discharge-air-temp-setpoint"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/office-ahu-duct-after-air-filter",
+ "@id": "urn:ex/room-203-in",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/connection-to-room-203"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -5890,55 +5519,86 @@
]
},
{
- "@id": "urn:ex/zone-206-co2-concentration",
+ "@id": "urn:ex/vav-515-discharge-air-temp",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#ofSubstance": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "http://data.ashrae.org/standard223#Substance-CO2"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/MoleFraction"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PPM"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-507-more-heat-requests",
+ "@id": "urn:ex/vav-526-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/vav-526-reheat-coil-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-526-reheat-coil-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-526-reheat-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-526-reheat-coil-water-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasRole": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/vav-514-reheat-coil-valve-actuator",
+ "@id": "urn:ex/vav-506-damper-actuator",
"@type": [
"http://data.ashrae.org/standard223#Actuator"
],
"http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/vav-514-reheat-coil-valve"
+ "@id": "urn:ex/vav-506-damper"
}
],
"http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/vav-514-reheat-coil-valve-command"
+ "@id": "urn:ex/vav-506-damper-command"
}
]
},
{
- "@id": "urn:ex/zone-312-cooling-setpoint",
+ "@id": "urn:ex/vav-504-discharge-air-flow-sensor",
+ "@type": [
+ "http://data.ashrae.org/standard223#Sensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "urn:ex/vav-504-air-in"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:ex/vav-504-discharge-air-flow"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-109-cooling-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -5954,114 +5614,72 @@
]
},
{
- "@id": "urn:ex/vav-502-reheat-coil-air-out",
+ "@id": "urn:ex/vav-514-discharge-air-flow",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/connection-to-room-101"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-502-heating-pid-output"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-502-more-heat-requests"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-502-air-out"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-535-air-out",
+ "@id": "urn:ex/room-313-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-311"
+ "@id": "urn:ex/connection-to-room-313"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-535-discharge-air-flow"
- },
- {
- "@id": "urn:ex/vav-535-discharge-air-flow-setpoint"
- },
- {
- "@id": "urn:ex/vav-535-discharge-air-temp"
- },
- {
- "@id": "urn:ex/vav-535-discharge-air-temp-setpoint"
- }
]
},
{
- "@id": "urn:ex/vav-524-discharge-air-flow-sensor",
+ "@id": "urn:ex/vav-509-discharge-air-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-524-air-in"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-524-discharge-air-flow"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-513",
+ "@id": "urn:ex/vav-513-hot-water-in-connection",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-513-air-in"
- },
- {
- "@id": "urn:ex/vav-513-air-out"
- },
- {
- "@id": "urn:ex/vav-513-hot-water-in"
- },
- {
- "@id": "urn:ex/vav-513-hot-water-out"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/vav-513-damper"
- },
- {
- "@id": "urn:ex/vav-513-reheat-coil"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-513-reheat-coil-valve"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-501-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/vav-514-hot-water-in-connection",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Pipe"
@@ -6073,7 +5691,7 @@
]
},
{
- "@id": "urn:ex/vav-503-hot-water-in-connection",
+ "@id": "urn:ex/vav-527-hot-water-out-connection",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Pipe"
@@ -6085,7 +5703,7 @@
]
},
{
- "@id": "urn:ex/vav-528-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/vav-503-hot-water-in-connection",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Pipe"
@@ -6097,475 +5715,419 @@
]
},
{
- "@id": "urn:ex/office-ahu-htg-coil",
+ "@id": "urn:ex/vav-512-air-in",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-htg-coil-air-in"
- },
- {
- "@id": "urn:ex/office-ahu-htg-coil-air-out"
- },
- {
- "@id": "urn:ex/office-ahu-htg-coil-water-in"
- },
- {
- "@id": "urn:ex/office-ahu-htg-coil-water-out"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/room-204-hvac-domain",
+ "@id": "urn:ex/vav-507-air-out",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-204-in"
- },
- {
- "@id": "urn:ex/room-204-out"
+ "@id": "urn:ex/connection-to-room-110"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/vav-519-discharge-air-flow-setpoint",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "urn:ex/vav-507-discharge-air-flow"
+ },
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:ex/vav-507-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-507-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-507-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/vav-501-discharge-air-flow-setpoint",
+ "@id": "urn:ex/vav-501-discharge-air-temp-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-533-reheat-coil-air-out",
+ "@id": "urn:ex/vav-533",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-305"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:ex/vav-533-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-533-air-out"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-533-hot-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-533-hot-water-out"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/vav-533-heating-pid-output"
+ "@id": "urn:ex/vav-533-damper"
},
{
- "@id": "urn:ex/vav-533-more-heat-requests"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "@id": "urn:ex/vav-533-reheat-coil"
+ },
{
- "@id": "urn:ex/vav-533-air-out"
+ "@id": "urn:ex/vav-533-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/vav-520-reheat-coil-valve-command",
+ "@id": "urn:ex/office-ahu-ra-flow",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasAspect": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Return"
+ }
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-509-damper-in",
+ "@id": "urn:ex/room-211-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-509-air-in"
- }
]
},
{
- "@id": "urn:ex/vav-507-duct-after-damper",
+ "@id": "urn:ex/vav-535-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-535-duct-after-damper"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/zone-104-occupancy-override",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "urn:ex/vav-535-colder-supply-air-requests"
+ },
+ {
+ "@id": "urn:ex/vav-535-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/zone-116-117",
+ "@id": "urn:ex/vav-503-air-out",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/room-116-hvac-domain"
- },
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-117-hvac-domain"
+ "@id": "urn:ex/connection-to-room-104"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/zone-116-117-cooling-setpoint"
- },
- {
- "@id": "urn:ex/zone-116-117-heating-setpoint"
- },
- {
- "@id": "urn:ex/zone-116-117-occupancy"
+ "@id": "urn:ex/vav-503-discharge-air-flow"
},
{
- "@id": "urn:ex/zone-116-117-occupancy-override"
+ "@id": "urn:ex/vav-503-discharge-air-flow-setpoint"
},
{
- "@id": "urn:ex/zone-116-117-temp"
+ "@id": "urn:ex/vav-503-discharge-air-temp"
},
{
- "@id": "urn:ex/zone-116-117-window-switch-on-off"
+ "@id": "urn:ex/vav-503-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/room-312-in",
+ "@id": "urn:ex/room-309-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-312"
+ "@id": "urn:ex/room-309-in"
+ },
+ {
+ "@id": "urn:ex/room-309-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-522",
+ "@id": "urn:ex/vav-535-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-522-air-in"
+ "@id": "urn:ex/vav-535-reheat-coil-air-in"
},
{
- "@id": "urn:ex/vav-522-air-out"
+ "@id": "urn:ex/vav-535-reheat-coil-air-out"
},
{
- "@id": "urn:ex/vav-522-hot-water-in"
+ "@id": "urn:ex/vav-535-reheat-coil-water-in"
},
{
- "@id": "urn:ex/vav-522-hot-water-out"
+ "@id": "urn:ex/vav-535-reheat-coil-water-out"
}
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/vav-522-damper"
- },
- {
- "@id": "urn:ex/vav-522-reheat-coil"
- },
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "urn:ex/vav-522-reheat-coil-valve"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/vav-520-reheat-coil-valve-position",
+ "@id": "urn:ex/zone-115-occupancy-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/room-115-hvac-domain"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/zone-115-occupancy"
}
]
},
{
- "@id": "urn:ex/vav-520-discharge-air-flow-sensor",
+ "@id": "urn:ex/zone-305-cooling-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-520-air-in"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-520-discharge-air-flow"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/room-307-hvac-domain",
+ "@id": "urn:ex/vav-530-hot-water-in-connection",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/room-307-in"
- },
- {
- "@id": "urn:ex/room-307-out"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-522-damper-in",
+ "@id": "urn:ex/vav-533-reheat-coil-valve-command",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/office-ahu-connection-to-vavs"
- }
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-522-air-in"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-527-damper-actuator",
+ "@id": "urn:ex/vav-535-heating-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-527-damper"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-527-damper-command"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/zone-104-temp-sensor",
+ "@id": "urn:ex/zone-105-temp",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-104-hvac-domain"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/zone-104-temp"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/room-306-in",
+ "@id": "urn:ex/zone-116-117-temp",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/connection-to-room-303-304-306"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-535-hot-water-in-connection",
+ "@id": "urn:ex/zone-214",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/room-214-hvac-domain"
}
- ]
- },
- {
- "@id": "urn:ex/vav-508",
- "@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:ex/vav-508-air-in"
- },
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-508-air-out"
+ "@id": "urn:ex/zone-214-cooling-setpoint"
},
{
- "@id": "urn:ex/vav-508-hot-water-in"
+ "@id": "urn:ex/zone-214-heating-setpoint"
},
{
- "@id": "urn:ex/vav-508-hot-water-out"
- }
- ],
- "http://data.ashrae.org/standard223#contains": [
+ "@id": "urn:ex/zone-214-occupancy"
+ },
{
- "@id": "urn:ex/vav-508-damper"
+ "@id": "urn:ex/zone-214-occupancy-override"
},
{
- "@id": "urn:ex/vav-508-reheat-coil"
+ "@id": "urn:ex/zone-214-temp"
},
{
- "@id": "urn:ex/vav-508-reheat-coil-valve"
+ "@id": "urn:ex/zone-214-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-507-reheat-coil-water-in",
+ "@id": "urn:ex/vav-540-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-507-hot-water-in-connection"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-507-hot-water-in"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-504-discharge-air-flow-sensor",
+ "@id": "urn:ex/room-107-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-504-air-in"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
+ "@id": "urn:ex/room-107-in"
+ },
{
- "@id": "urn:ex/vav-504-discharge-air-flow"
+ "@id": "urn:ex/room-107-out"
}
- ]
- },
- {
- "@id": "urn:ex/room-116",
- "@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:ex/room-116-hvac-domain"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-501-damper-command",
+ "@id": "urn:ex/vav-513-reheat-coil-valve-position",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -6579,35 +6141,13 @@
]
},
{
- "@id": "urn:ex/vav-513-colder-supply-air-requests",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-520-colder-supply-air-requests",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-507-damper-out",
+ "@id": "urn:ex/vav-519-reheat-coil-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-507-duct-after-damper"
+ "@id": "urn:ex/connection-to-room-204-205"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -6617,63 +6157,52 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-507-colder-supply-air-requests"
+ "@id": "urn:ex/vav-519-heating-pid-output"
},
{
- "@id": "urn:ex/vav-507-cooling-pid-output"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-504-reheat-coil-air-in",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-504-duct-after-damper"
+ "@id": "urn:ex/vav-519-more-heat-requests"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-519-air-out"
}
]
},
{
- "@id": "urn:ex/vav-501-reheat-coil-air-in",
+ "@id": "urn:ex/vav-501-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-501-duct-after-damper"
+ "@id": "urn:ex/vav-501-air-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-501-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/vav-520-reheat-coil",
+ "@id": "urn:ex/vav-534-reheat-coil",
"@type": [
"http://data.ashrae.org/standard223#HeatingCoil",
"http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-520-reheat-coil-air-in"
+ "@id": "urn:ex/vav-534-reheat-coil-air-in"
},
{
- "@id": "urn:ex/vav-520-reheat-coil-air-out"
+ "@id": "urn:ex/vav-534-reheat-coil-air-out"
},
{
- "@id": "urn:ex/vav-520-reheat-coil-water-in"
+ "@id": "urn:ex/vav-534-reheat-coil-water-in"
},
{
- "@id": "urn:ex/vav-520-reheat-coil-water-out"
+ "@id": "urn:ex/vav-534-reheat-coil-water-out"
}
],
"http://data.ashrae.org/standard223#hasRole": [
@@ -6683,351 +6212,356 @@
]
},
{
- "@id": "urn:ex/vav-516-discharge-air-temp-sensor",
+ "@id": "urn:ex/vav-538-air-out",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-516-air-out"
+ "@id": "urn:ex/connection-to-room-213"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-516-discharge-air-temp"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/zone-210-occupancy",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "urn:ex/vav-538-discharge-air-flow"
+ },
+ {
+ "@id": "urn:ex/vav-538-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-538-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-538-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/vav-521-reheat-coil-valve-position",
+ "@id": "urn:ex/room-204-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/room-204-in"
+ },
+ {
+ "@id": "urn:ex/room-204-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-503-damper",
+ "@id": "urn:ex/vav-501-hot-water-in-connection",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-503-damper-in"
- },
- {
- "@id": "urn:ex/vav-503-damper-out"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-503-damper-command"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-503-damper-position"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-513-more-heat-requests",
+ "@id": "urn:ex/office-ahu-sa-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/office-ahu-sa-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:ex/office-ahu-sa-temp"
}
]
},
{
- "@id": "urn:ex/vav-504-hot-water-in-connection",
+ "@id": "urn:ex/zone-312-occupancy",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
]
},
{
- "@id": "urn:ex/office-ahu-ea-out",
+ "@id": "urn:ex/vav-519-damper-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-ea-out-connection"
+ "@id": "urn:ex/vav-519-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-519-colder-supply-air-requests"
+ },
+ {
+ "@id": "urn:ex/vav-519-cooling-pid-output"
+ }
]
},
{
- "@id": "urn:ex/vav-529-discharge-air-temp",
+ "@id": "urn:ex/vav-509-heating-pid-output",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
- ],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/office-ahu-ra-temp-sensor",
+ "@id": "urn:ex/vav-502-hot-water-in",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-ra-in"
+ "@id": "urn:ex/vav-502-hot-water-in-connection"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/office-ahu-ra-temp"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-538-hot-water-in-connection",
+ "@id": "urn:ex/room-205-out",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-524-damper-position",
+ "@id": "urn:ex/zone-109-occupancy-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/room-109-hvac-domain"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/zone-109-occupancy"
}
]
},
{
- "@id": "urn:ex/zone-111-cooling-setpoint",
+ "@id": "urn:ex/vav-535-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-535-damper"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-535-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-502-reheat-coil-valve-command",
+ "@id": "urn:ex/vav-517-discharge-air-flow",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasAspect": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-507-damper",
+ "@id": "urn:ex/vav-538",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-507-damper-in"
+ "@id": "urn:ex/vav-538-air-in"
},
{
- "@id": "urn:ex/vav-507-damper-out"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "@id": "urn:ex/vav-538-air-out"
+ },
{
- "@id": "urn:ex/vav-507-damper-command"
+ "@id": "urn:ex/vav-538-hot-water-in"
},
{
- "@id": "urn:ex/vav-507-damper-position"
+ "@id": "urn:ex/vav-538-hot-water-out"
}
- ]
- },
- {
- "@id": "urn:ex/room-106-in",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/connection-to-room-106-107"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:ex/vav-538-damper"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-538-reheat-coil"
+ },
+ {
+ "@id": "urn:ex/vav-538-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/room-313-out",
+ "@id": "urn:ex/zone-214-occupancy",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/office-ahu-connection-from-rooms"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
]
},
{
- "@id": "urn:ex/vav-526-reheat-coil",
+ "@id": "urn:ex/vav-516",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-526-reheat-coil-air-in"
+ "@id": "urn:ex/vav-516-air-in"
},
{
- "@id": "urn:ex/vav-526-reheat-coil-air-out"
+ "@id": "urn:ex/vav-516-air-out"
},
{
- "@id": "urn:ex/vav-526-reheat-coil-water-in"
+ "@id": "urn:ex/vav-516-hot-water-in"
},
{
- "@id": "urn:ex/vav-526-reheat-coil-water-out"
+ "@id": "urn:ex/vav-516-hot-water-out"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "urn:ex/vav-516-damper"
+ },
+ {
+ "@id": "urn:ex/vav-516-reheat-coil"
+ },
+ {
+ "@id": "urn:ex/vav-516-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/vav-519-damper-out",
+ "@id": "urn:ex/connection-to-room-207",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-519-duct-after-damper"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-507-more-heat-requests",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-519-colder-supply-air-requests"
- },
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-519-cooling-pid-output"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-530-damper-actuator",
+ "@id": "urn:ex/zone-212-occupancy-override",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-530-damper"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-527-colder-supply-air-requests",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-530-damper-command"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-535-reheat-coil-water-in",
+ "@id": "urn:ex/vav-534-reheat-coil-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-535-hot-water-in-connection"
+ "@id": "urn:ex/vav-534-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-535-hot-water-in"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-525-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/vav-508-pipe-hot-water-return-before-valve",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Pipe"
@@ -7039,158 +6573,157 @@
]
},
{
- "@id": "urn:ex/room-116-in",
+ "@id": "urn:ex/vav-538-hot-water-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-116-117"
+ "@id": "urn:ex/vav-538-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-506-discharge-air-temp-sensor",
+ "@id": "urn:ex/zone-102-temp",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-506-air-out"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-506-discharge-air-temp"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-526-reheat-coil-valve-in",
+ "@id": "urn:ex/zone-312-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-526-pipe-hot-water-return-before-valve"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-516-reheat-coil-valve",
+ "@id": "urn:ex/vav-503-reheat-coil-air-in",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-516-reheat-coil-valve-in"
- },
- {
- "@id": "urn:ex/vav-516-reheat-coil-valve-out"
+ "@id": "urn:ex/vav-503-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-516-reheat-coil-valve-command"
- },
- {
- "@id": "urn:ex/vav-516-reheat-coil-valve-position"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/office-ahu-ra-fan-start-cmd",
+ "@id": "urn:ex/zone-303-304-306",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "urn:ex/room-303-hvac-domain"
+ },
+ {
+ "@id": "urn:ex/room-304-hvac-domain"
+ },
+ {
+ "@id": "urn:ex/room-306-hvac-domain"
}
- ]
- },
- {
- "@id": "urn:ex/zone-101-temp-sensor",
- "@type": [
- "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:ex/room-101-hvac-domain"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/zone-101-temp"
+ "@id": "urn:ex/zone-303-304-306-cooling-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-303-304-306-heating-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-303-304-306-occupancy"
+ },
+ {
+ "@id": "urn:ex/zone-303-304-306-occupancy-override"
+ },
+ {
+ "@id": "urn:ex/zone-303-304-306-temp"
+ },
+ {
+ "@id": "urn:ex/zone-303-304-306-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-508-discharge-air-flow-setpoint",
+ "@id": "urn:ex/vav-530-damper-command",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/zone-311-temp-sensor",
+ "@id": "urn:ex/room-118-out",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-311-hvac-domain"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-311-temp"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-524-damper-in",
+ "@id": "urn:ex/vav-508-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/office-ahu-connection-to-vavs"
- }
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-508-air-out"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-524-air-in"
+ "@id": "urn:ex/vav-508-discharge-air-temp"
}
]
},
@@ -7232,357 +6765,410 @@
]
},
{
- "@id": "urn:ex/vav-507-reheat-coil-valve",
+ "@id": "urn:ex/vav-521-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-507-reheat-coil-valve-in"
- },
- {
- "@id": "urn:ex/vav-507-reheat-coil-valve-out"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-507-reheat-coil-valve-command"
- },
+ "@id": "urn:ex/vav-521-air-in"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-538-hot-water-in-connection",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-507-reheat-coil-valve-position"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-502-hot-water-out",
+ "@id": "urn:ex/vav-519-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-502-hot-water-out-connection"
+ "@id": "urn:ex/vav-519-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-519-hot-water-in"
+ }
]
},
{
- "@id": "urn:ex/zone-102-window-switch-on-off",
+ "@id": "urn:ex/vav-511-cooling-pid-output",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-213-occupancy-override",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
]
},
{
- "@id": "urn:ex/vav-536-reheat-coil",
+ "@id": "urn:ex/zone-314-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-536-reheat-coil-air-in"
- },
+ "@id": "urn:ex/room-314-hvac-domain"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-536-reheat-coil-air-out"
- },
+ "@id": "urn:ex/zone-314-temp"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-505-reheat-coil-valve-position",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-536-reheat-coil-water-in"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-536-reheat-coil-water-out"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-506-discharge-air-flow-sensor",
+ "@type": [
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "urn:ex/vav-506-air-in"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:ex/vav-506-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/vav-535-reheat-coil-valve-out",
+ "@id": "urn:ex/vav-538-discharge-air-temp",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/vav-535-hot-water-out-connection"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-535-hot-water-out"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/zone-302-co2-sensor",
+ "@id": "urn:ex/vav-537-discharge-air-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-302-hvac-domain"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/zone-302-co2-concentration"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/zone-109-occupancy-sensor",
+ "@id": "urn:ex/room-103-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-109-hvac-domain"
+ "@id": "urn:ex/room-103-in"
+ },
+ {
+ "@id": "urn:ex/room-103-out"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:ex/zone-109-occupancy"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/connection-to-room-118",
+ "@id": "urn:ex/zone-314-temp",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-531-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/vav-535-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-512-reheat-coil-air-out",
+ "@id": "urn:ex/vav-511-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-118"
+ "@id": "urn:ex/vav-511-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-536-damper-in",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-512-heating-pid-output"
- },
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-512-more-heat-requests"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-512-air-out"
+ "@id": "urn:ex/vav-536-air-in"
}
]
},
{
- "@id": "urn:ex/zone-109-temp",
+ "@id": "urn:ex/vav-534-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-534-reheat-coil-valve"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-534-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/zone-115-occupancy",
+ "@id": "urn:ex/vav-507-reheat-coil-valve-position",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
- ]
- },
- {
- "@id": "urn:ex/vav-509-hot-water-out-connection",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-510-damper-actuator",
+ "@id": "urn:ex/vav-538-discharge-air-flow-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-510-damper"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-510-damper-command"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-539",
+ "@id": "urn:ex/vav-504",
"@type": [
"http://data.ashrae.org/standard223#SingleDuctTerminal",
"http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-539-air-in"
+ "@id": "urn:ex/vav-504-air-in"
},
{
- "@id": "urn:ex/vav-539-air-out"
+ "@id": "urn:ex/vav-504-air-out"
},
{
- "@id": "urn:ex/vav-539-hot-water-in"
+ "@id": "urn:ex/vav-504-hot-water-in"
},
{
- "@id": "urn:ex/vav-539-hot-water-out"
+ "@id": "urn:ex/vav-504-hot-water-out"
}
],
"http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/vav-539-damper"
+ "@id": "urn:ex/vav-504-damper"
},
{
- "@id": "urn:ex/vav-539-reheat-coil"
+ "@id": "urn:ex/vav-504-reheat-coil"
},
{
- "@id": "urn:ex/vav-539-reheat-coil-valve"
+ "@id": "urn:ex/vav-504-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/vav-515-heating-pid-output",
+ "@id": "urn:ex/zone-203-occupancy",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
]
},
{
- "@id": "urn:ex/vav-540-reheat-coil-valve-command",
+ "@id": "urn:ex/vav-513-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-513-pipe-hot-water-return-before-valve"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-535-duct-after-damper",
+ "@id": "urn:ex/zone-116-117-window-switch-on-off",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/vav-523-heating-pid-output",
+ "@id": "urn:ex/room-203-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/room-203-in"
+ },
+ {
+ "@id": "urn:ex/room-203-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-504-discharge-air-temp-sensor",
+ "@id": "urn:ex/connection-to-room-212",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:ex/vav-504-air-out"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-504-discharge-air-temp"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-539-colder-supply-air-requests",
+ "@id": "urn:ex/vav-504-more-heat-requests",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
@@ -7593,131 +7179,185 @@
]
},
{
- "@id": "urn:ex/vav-513-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/vav-534-duct-after-damper",
"@type": [
"http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-503-damper-in",
+ "@id": "urn:ex/vav-517-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-517-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-111-temp",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-503-air-in"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/room-312-hvac-domain",
+ "@id": "urn:ex/vav-533-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-312-in"
+ "@id": "urn:ex/vav-533-reheat-coil-air-in"
},
{
- "@id": "urn:ex/room-312-out"
+ "@id": "urn:ex/vav-533-reheat-coil-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-533-reheat-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-533-reheat-coil-water-out"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/vav-517-discharge-air-temp-sensor",
+ "@id": "urn:ex/vav-502-discharge-air-flow",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/vav-517-air-out"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-517-discharge-air-temp"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-506-duct-after-damper",
+ "@id": "urn:ex/vav-508-more-heat-requests",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ {
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-525-reheat-coil-water-in",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-525-hot-water-in-connection"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-525-hot-water-in"
}
]
},
{
- "@id": "urn:ex/vav-518-colder-supply-air-requests",
+ "@id": "urn:ex/vav-518-reheat-coil-valve-out",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/vav-518-hot-water-out-connection"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-518-hot-water-out"
}
]
},
{
- "@id": "urn:ex/vav-506-reheat-coil",
+ "@id": "urn:ex/vav-515",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-506-reheat-coil-air-in"
+ "@id": "urn:ex/vav-515-air-in"
},
{
- "@id": "urn:ex/vav-506-reheat-coil-air-out"
+ "@id": "urn:ex/vav-515-air-out"
},
{
- "@id": "urn:ex/vav-506-reheat-coil-water-in"
+ "@id": "urn:ex/vav-515-hot-water-in"
},
{
- "@id": "urn:ex/vav-506-reheat-coil-water-out"
+ "@id": "urn:ex/vav-515-hot-water-out"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "urn:ex/vav-515-damper"
+ },
+ {
+ "@id": "urn:ex/vav-515-reheat-coil"
+ },
+ {
+ "@id": "urn:ex/vav-515-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/vav-514-discharge-air-temp",
+ "@id": "urn:ex/zone-116-117-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -7731,57 +7371,63 @@
]
},
{
- "@id": "urn:ex/room-104-in",
+ "@id": "urn:ex/vav-518-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-104"
+ "@id": "urn:ex/vav-518-reheat-coil-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-518-reheat-coil-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-518-reheat-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-518-reheat-coil-water-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/vav-536-heating-pid-output",
+ "@id": "urn:ex/vav-510-discharge-air-flow-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-523-damper-position",
+ "@id": "urn:ex/vav-522-hot-water-out-connection",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-538-damper-position",
+ "@id": "urn:ex/vav-509-reheat-coil-valve-command",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -7795,82 +7441,98 @@
]
},
{
- "@id": "urn:ex/vav-510-reheat-coil-valve-actuator",
+ "@id": "urn:ex/zone-307-308-occupancy-override",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-510-reheat-coil-valve"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-521-reheat-coil-air-in",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-510-reheat-coil-valve-command"
+ "@id": "urn:ex/vav-521-duct-after-damper"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/zone-214-occupancy",
+ "@id": "urn:ex/vav-534-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "urn:ex/vav-534-pipe-hot-water-return-before-valve"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-515-cooling-pid-output",
+ "@id": "urn:ex/vav-517-reheat-coil-valve-command",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-539-discharge-air-flow-setpoint",
+ "@id": "urn:ex/vav-503-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:ex/vav-503-damper"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:ex/vav-503-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-506-damper-command",
+ "@id": "urn:ex/vav-517-heating-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-503-air-in",
+ "@id": "urn:ex/vav-511-damper-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -7883,120 +7545,196 @@
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-511-air-in"
+ }
]
},
{
- "@id": "urn:ex/vav-526-reheat-coil-water-out",
+ "@id": "urn:ex/connection-to-room-214",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-526-pipe-hot-water-return-before-valve"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/connection-to-room-102",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/zone-204-205-occupancy-sensor",
+ "@id": "urn:ex/vav-529-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-204-hvac-domain"
+ "@id": "urn:ex/vav-529-reheat-coil-valve-in"
+ },
+ {
+ "@id": "urn:ex/vav-529-reheat-coil-valve-out"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-204-205-occupancy"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-529-reheat-coil-valve-command"
+ },
+ {
+ "@id": "urn:ex/vav-529-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/office-ahu-htg-coil-valve-actuator",
+ "@id": "urn:ex/zone-309-310-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/office-ahu-htg-coil-valve"
+ "@id": "urn:ex/room-309-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/office-ahu-htg-coil-valve-command"
+ "@id": "urn:ex/zone-309-310-temp"
}
]
},
{
- "@id": "urn:ex/zone-303-304-306-occupancy-sensor",
+ "@id": "urn:ex/zone-213-window-switch-on-off",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/room-303-hvac-domain"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-521-hot-water-out-connection",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-303-304-306-occupancy"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/zone-203-window-switch-on-off",
+ "@id": "urn:ex/zone-101-occupancy",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
]
},
{
- "@id": "urn:ex/connection-to-room-201",
+ "@id": "urn:ex/office-ahu-clg-coil-water-out",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/office-ahu-pipe-chilled-water-return-before-valve"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-531-hot-water-out-connection",
"@type": [
"http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-522-discharge-air-flow-setpoint",
+ "@id": "urn:ex/vav-527-discharge-air-temp",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasAspect": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-518-discharge-air-flow-sensor",
+ "@type": [
+ "http://data.ashrae.org/standard223#Sensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "urn:ex/vav-518-air-in"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:ex/vav-518-discharge-air-flow"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-213-occupancy",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ {
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
]
},
{
- "@id": "urn:ex/vav-507-air-in",
+ "@id": "urn:ex/connection-to-room-314",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/office-ahu-connection-to-vavs"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -8005,153 +7743,180 @@
]
},
{
- "@id": "urn:ex/vav-507-discharge-air-temp",
+ "@id": "urn:ex/zone-215-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ "@id": "urn:ex/room-215-hvac-domain"
}
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/zone-215-temp"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-214-occupancy-override",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
]
},
{
- "@id": "urn:ex/room-209",
+ "@id": "urn:ex/vav-515-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/room-209-hvac-domain"
+ "@id": "urn:ex/vav-515-reheat-coil-valve"
+ }
+ ],
+ "http://data.ashrae.org/standard223#commandedByProperty": [
+ {
+ "@id": "urn:ex/vav-515-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/vav-537-reheat-coil-air-out",
+ "@id": "urn:ex/vav-506-reheat-coil-valve-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-312"
+ "@id": "urn:ex/vav-506-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-537-heating-pid-output"
- },
+ "@id": "urn:ex/vav-506-hot-water-out"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/connection-to-room-109",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-537-more-heat-requests"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-524-hot-water-in-connection",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-537-air-out"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/office-ahu-htg-coil-water-in",
+ "@id": "urn:ex/office-ahu-ea-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-hot-water-in-connection"
+ "@id": "urn:ex/office-ahu-ea-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/office-ahu-hot-water-in"
+ "@id": "urn:ex/office-ahu-ea-out"
}
]
},
{
- "@id": "urn:ex/zone-301-occupancy-sensor",
+ "@id": "urn:ex/vav-534-reheat-coil-valve-command",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-301-hvac-domain"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/zone-301-occupancy"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/room-204-out",
+ "@id": "urn:ex/office-ahu-sa-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/office-ahu-sa-fan-in"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/office-ahu-sa-flow"
}
]
},
{
- "@id": "urn:ex/zone-101-building-static-pressure",
+ "@id": "urn:ex/zone-213-temp",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/IN_H2O"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-527-damper-position",
+ "@id": "urn:ex/zone-108-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-526-discharge-air-temp-setpoint",
+ "@id": "urn:ex/vav-520-discharge-air-temp-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -8167,57 +7932,67 @@
]
},
{
- "@id": "urn:ex/vav-527-reheat-coil-air-in",
+ "@id": "urn:ex/vav-504-hot-water-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-527-duct-after-damper"
+ "@id": "urn:ex/vav-504-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-507-colder-supply-air-requests",
+ "@id": "urn:ex/vav-517-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/vav-517-reheat-coil-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-517-reheat-coil-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-517-reheat-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-517-reheat-coil-water-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasRole": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/vav-539-reheat-coil-valve-actuator",
+ "@id": "urn:ex/office-ahu-supply-duct-static-pressure-sensor",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-539-reheat-coil-valve"
+ "@id": "urn:ex/office-ahu-sa-out"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-539-reheat-coil-valve-command"
+ "@id": "urn:ex/office-ahu-supply-duct-static-pressure"
}
]
},
{
- "@id": "urn:ex/vav-501-discharge-air-temp",
+ "@id": "urn:ex/zone-303-304-306-cooling-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -8231,137 +8006,164 @@
]
},
{
- "@id": "urn:ex/zone-215",
+ "@id": "urn:ex/vav-505-damper",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-215-hvac-domain"
- }
- ],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "@id": "urn:ex/vav-505-damper-in"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "urn:ex/vav-505-damper-out"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/zone-215-cooling-setpoint"
- },
- {
- "@id": "urn:ex/zone-215-heating-setpoint"
- },
- {
- "@id": "urn:ex/zone-215-occupancy"
- },
- {
- "@id": "urn:ex/zone-215-occupancy-override"
+ "@id": "urn:ex/vav-505-damper-command"
},
{
- "@id": "urn:ex/zone-215-temp"
- },
+ "@id": "urn:ex/vav-505-damper-position"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-514-hot-water-out-connection",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-215-window-switch-on-off"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-503-reheat-coil-valve-command",
+ "@id": "urn:ex/vav-527-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-527-pipe-hot-water-return-before-valve"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-511-damper-in",
+ "@id": "urn:ex/room-212-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-537-pipe-hot-water-return-before-valve",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-511-air-in"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-529-cooling-pid-output",
+ "@id": "urn:ex/vav-528-duct-after-damper",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-301-heating-setpoint",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-515-colder-supply-air-requests",
+ "@id": "urn:ex/vav-519-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/vav-519-pipe-hot-water-return-before-valve"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-525-damper",
+ "@id": "urn:ex/vav-530-pipe-hot-water-return-before-valve",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-525-damper-in"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-525-damper-out"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-536-hot-water-in",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-525-damper-command"
- },
+ "@id": "urn:ex/vav-536-hot-water-in-connection"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-525-damper-position"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-508-air-out",
+ "@id": "urn:ex/vav-527-reheat-coil-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-109"
+ "@id": "urn:ex/connection-to-room-301"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -8371,461 +8173,519 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-508-discharge-air-flow"
- },
- {
- "@id": "urn:ex/vav-508-discharge-air-flow-setpoint"
+ "@id": "urn:ex/vav-527-heating-pid-output"
},
{
- "@id": "urn:ex/vav-508-discharge-air-temp"
- },
+ "@id": "urn:ex/vav-527-more-heat-requests"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-508-discharge-air-temp-setpoint"
+ "@id": "urn:ex/vav-527-air-out"
}
]
},
{
- "@id": "urn:ex/vav-505-air-out",
+ "@id": "urn:ex/vav-533-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-108"
+ "@id": "urn:ex/vav-533-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-505-discharge-air-flow"
- },
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-505-discharge-air-flow-setpoint"
- },
+ "@id": "urn:ex/vav-533-hot-water-in"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-514-damper-actuator",
+ "@type": [
+ "http://data.ashrae.org/standard223#Actuator"
+ ],
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/vav-505-discharge-air-temp"
- },
+ "@id": "urn:ex/vav-514-damper"
+ }
+ ],
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/vav-505-discharge-air-temp-setpoint"
+ "@id": "urn:ex/vav-514-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-501-air-in",
+ "@id": "urn:ex/vav-521-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-530-reheat-coil-valve",
+ "@id": "urn:ex/vav-521-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-530-reheat-coil-valve-in"
- },
- {
- "@id": "urn:ex/vav-530-reheat-coil-valve-out"
+ "@id": "urn:ex/vav-521-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-521-reheat-coil",
+ "@type": [
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-530-reheat-coil-valve-command"
+ "@id": "urn:ex/vav-521-reheat-coil-air-in"
},
{
- "@id": "urn:ex/vav-530-reheat-coil-valve-position"
+ "@id": "urn:ex/vav-521-reheat-coil-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-521-reheat-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-521-reheat-coil-water-out"
}
- ]
- },
- {
- "@id": "urn:ex/zone-214-occupancy-override",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/vav-514-discharge-air-temp-sensor",
+ "@id": "urn:ex/zone-103-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-514-air-out"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-514-discharge-air-temp"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/connection-to-room-305",
+ "@id": "urn:ex/vav-536-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-536-hot-water-out-connection"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-522-heating-pid-output",
+ "@id": "urn:ex/vav-521-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/vav-521-pipe-hot-water-return-before-valve"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-518-air-in",
+ "@id": "urn:ex/vav-510-reheat-coil-valve-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-510-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-510-hot-water-out"
}
]
},
{
- "@id": "urn:ex/vav-528-reheat-coil-air-in",
+ "@id": "urn:ex/vav-537-discharge-air-flow",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/vav-528-duct-after-damper"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/connection-to-room-110",
+ "@id": "urn:ex/vav-536-air-out",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/connection-to-room-313"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-536-discharge-air-flow"
+ },
+ {
+ "@id": "urn:ex/vav-536-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-536-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-536-discharge-air-temp-setpoint"
+ }
]
},
{
- "@id": "urn:ex/vav-530-hot-water-out-connection",
+ "@id": "urn:ex/office-ahu-htg-coil-valve-position",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-538-duct-after-damper",
+ "@id": "urn:ex/zone-309-310-window-switch-on-off",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/vav-516-air-in",
+ "@id": "urn:ex/zone-214-occupancy-sensor",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/room-214-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/zone-214-occupancy"
}
]
},
{
- "@id": "urn:ex/vav-528-damper",
+ "@id": "urn:ex/vav-510-discharge-air-flow",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-528-damper-in"
- },
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/vav-528-damper-out"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-528-damper-command"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-528-damper-position"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/zone-202-occupancy-override",
+ "@id": "urn:ex/vav-509-discharge-air-flow-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-513-discharge-air-flow-setpoint",
+ "@id": "urn:ex/zone-311-cooling-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-501-reheat-coil-water-out",
+ "@id": "urn:ex/vav-517-discharge-air-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-501-pipe-hot-water-return-before-valve"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/office-ahu-oa-damper",
+ "@id": "urn:ex/vav-511-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-oa-damper-in"
+ "@id": "urn:ex/vav-511-reheat-coil-air-in"
},
{
- "@id": "urn:ex/office-ahu-oa-damper-out"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "@id": "urn:ex/vav-511-reheat-coil-air-out"
+ },
{
- "@id": "urn:ex/office-ahu-oa-damper-command"
+ "@id": "urn:ex/vav-511-reheat-coil-water-in"
},
{
- "@id": "urn:ex/office-ahu-oa-damper-position"
+ "@id": "urn:ex/vav-511-reheat-coil-water-out"
}
],
"http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Economizer"
- },
- {
- "@id": "http://data.ashrae.org/standard223#Role-Outside"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/office-ahu-oa-flow",
+ "@id": "urn:ex/vav-510-cooling-pid-output",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Outside"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-508-colder-supply-air-requests",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-530-damper-out",
+ "@id": "urn:ex/vav-507-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-530-duct-after-damper"
+ "@id": "urn:ex/vav-507-reheat-coil-valve-in"
+ },
+ {
+ "@id": "urn:ex/vav-507-reheat-coil-valve-out"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-530-colder-supply-air-requests"
+ "@id": "urn:ex/vav-507-reheat-coil-valve-command"
},
{
- "@id": "urn:ex/vav-530-cooling-pid-output"
+ "@id": "urn:ex/vav-507-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/room-211",
+ "@id": "urn:ex/vav-533-reheat-coil-valve-position",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-211-hvac-domain"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/room-103-in",
+ "@id": "urn:ex/vav-507-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-103"
+ "@id": "urn:ex/vav-507-reheat-coil-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-507-reheat-coil-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-507-reheat-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-507-reheat-coil-water-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/vav-525-damper-command",
+ "@id": "urn:ex/zone-302-cooling-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-517-duct-after-damper",
+ "@id": "urn:ex/vav-507-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-507-pipe-hot-water-return-before-valve"
}
- ]
- },
- {
- "@id": "urn:ex/vav-516-duct-after-damper",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-516-hot-water-in-connection",
+ "@id": "urn:ex/room-207",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/room-207-hvac-domain"
}
]
},
{
- "@id": "urn:ex/vav-530-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-523-reheat-coil-valve-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-530-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-523-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -8835,13 +8695,13 @@
]
},
{
- "@id": "urn:ex/vav-522-reheat-coil-valve-out",
+ "@id": "urn:ex/vav-536-reheat-coil-valve-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-522-hot-water-out-connection"
+ "@id": "urn:ex/vav-536-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -8851,132 +8711,156 @@
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-522-hot-water-out"
+ "@id": "urn:ex/vav-536-hot-water-out"
}
]
},
{
- "@id": "urn:ex/vav-534-reheat-coil-valve-in",
+ "@id": "urn:ex/zone-305-occupancy-sensor",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "urn:ex/room-305-hvac-domain"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:ex/zone-305-occupancy"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-537-reheat-coil-valve-out",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-534-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-537-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-537-hot-water-out"
+ }
]
},
{
- "@id": "urn:ex/connection-to-room-314",
+ "@id": "urn:ex/vav-536-discharge-air-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-515",
+ "@id": "urn:ex/vav-513-damper",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-515-air-in"
- },
- {
- "@id": "urn:ex/vav-515-air-out"
- },
- {
- "@id": "urn:ex/vav-515-hot-water-in"
+ "@id": "urn:ex/vav-513-damper-in"
},
{
- "@id": "urn:ex/vav-515-hot-water-out"
+ "@id": "urn:ex/vav-513-damper-out"
}
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/vav-515-damper"
- },
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-515-reheat-coil"
+ "@id": "urn:ex/vav-513-damper-command"
},
{
- "@id": "urn:ex/vav-515-reheat-coil-valve"
+ "@id": "urn:ex/vav-513-damper-position"
}
]
},
{
- "@id": "urn:ex/vav-522-damper-command",
+ "@id": "urn:ex/vav-540-reheat-coil-air-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/connection-to-room-215"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/zone-312-occupancy-override",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "urn:ex/vav-540-heating-pid-output"
+ },
+ {
+ "@id": "urn:ex/vav-540-more-heat-requests"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-540-air-out"
}
]
},
{
- "@id": "urn:ex/zone-118-occupancy-override",
+ "@id": "urn:ex/office-ahu-hot-water-in-connection",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-535-more-heat-requests",
+ "@id": "urn:ex/vav-520-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/vav-520-pipe-hot-water-return-before-valve"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/zone-212-window-switch-on-off",
+ "@id": "urn:ex/room-310",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "urn:ex/room-310-hvac-domain"
}
]
},
{
- "@id": "urn:ex/vav-527-reheat-coil-valve-command",
+ "@id": "urn:ex/office-ahu-clg-coil-valve-command",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -8992,120 +8876,137 @@
]
},
{
- "@id": "urn:ex/vav-501-reheat-coil",
+ "@id": "urn:ex/zone-201-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-501-reheat-coil-air-in"
- },
- {
- "@id": "urn:ex/vav-501-reheat-coil-air-out"
- },
- {
- "@id": "urn:ex/vav-501-reheat-coil-water-in"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-501-reheat-coil-water-out"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/zone-302-occupancy-sensor",
+ "@id": "urn:ex/vav-504-discharge-air-temp-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/room-302-hvac-domain"
+ "@id": "urn:ex/vav-504-air-out"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/zone-302-occupancy"
+ "@id": "urn:ex/vav-504-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/vav-517-damper-position",
+ "@id": "urn:ex/connection-to-room-105",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-103-occupancy-override",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
]
},
{
- "@id": "urn:ex/vav-508-discharge-air-flow-sensor",
+ "@id": "urn:ex/vav-527-damper-command",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-508-air-in"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-508-discharge-air-flow"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-524-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-539-air-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-524-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/connection-to-room-214"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-539-discharge-air-flow"
+ },
+ {
+ "@id": "urn:ex/vav-539-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-539-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-539-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/vav-506-reheat-coil-valve-out",
+ "@id": "urn:ex/zone-301-occupancy",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-506-hot-water-out-connection"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-525-discharge-air-temp-sensor",
+ "@type": [
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-525-air-out"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-506-hot-water-out"
+ "@id": "urn:ex/vav-525-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/zone-213-temp",
+ "@id": "urn:ex/zone-111-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -9119,100 +9020,78 @@
]
},
{
- "@id": "urn:ex/vav-512-reheat-coil-water-out",
+ "@id": "urn:ex/zone-312-temp",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-512-pipe-hot-water-return-before-valve"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-537-damper-out",
+ "@id": "urn:ex/zone-309-310-temp",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-537-duct-after-damper"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-537-colder-supply-air-requests"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-537-cooling-pid-output"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-502-air-out",
+ "@id": "urn:ex/vav-532-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/connection-to-room-101"
- }
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-532-air-in"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-502-discharge-air-flow"
- },
- {
- "@id": "urn:ex/vav-502-discharge-air-flow-setpoint"
- },
- {
- "@id": "urn:ex/vav-502-discharge-air-temp"
- },
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-502-discharge-air-temp-setpoint"
+ "@id": "urn:ex/vav-532-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/vav-531-reheat-coil-air-in",
+ "@id": "urn:ex/vav-527-discharge-air-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-531-duct-after-damper"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/zone-212",
+ "@id": "urn:ex/zone-111",
"@type": [
"http://data.ashrae.org/standard223#Zone",
"http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
"http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/room-212-hvac-domain"
+ "@id": "urn:ex/room-111-hvac-domain"
}
],
"http://data.ashrae.org/standard223#hasDomain": [
@@ -9222,108 +9101,131 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/zone-212-cooling-setpoint"
+ "@id": "urn:ex/zone-111-cooling-setpoint"
},
{
- "@id": "urn:ex/zone-212-heating-setpoint"
+ "@id": "urn:ex/zone-111-heating-setpoint"
},
{
- "@id": "urn:ex/zone-212-occupancy"
+ "@id": "urn:ex/zone-111-occupancy"
},
{
- "@id": "urn:ex/zone-212-occupancy-override"
+ "@id": "urn:ex/zone-111-occupancy-override"
},
{
- "@id": "urn:ex/zone-212-temp"
+ "@id": "urn:ex/zone-111-temp"
},
{
- "@id": "urn:ex/zone-212-window-switch-on-off"
+ "@id": "urn:ex/zone-111-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/room-117",
+ "@id": "urn:ex/vav-534-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-117-hvac-domain"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/zone-101-building-static-pressure-setpoint",
+ "@id": "urn:ex/vav-503-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ "@id": "urn:ex/vav-503-reheat-coil-valve"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://qudt.org/vocab/unit/IN_H2O"
+ "@id": "urn:ex/vav-503-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/zone-112-114-temp",
+ "@id": "urn:ex/vav-507-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-507-hot-water-in-connection"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-507-hot-water-in"
}
]
},
{
- "@id": "urn:ex/room-111-out",
+ "@id": "urn:ex/vav-540-duct-after-damper",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-539-hot-water-in-connection",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-501-hot-water-out",
+ "@id": "urn:ex/vav-507-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-501-hot-water-out-connection"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-507-air-in"
}
]
},
{
- "@id": "urn:ex/vav-517-reheat-coil-air-out",
+ "@id": "urn:ex/vav-533-damper-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-203"
+ "@id": "urn:ex/vav-533-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -9333,183 +9235,197 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-517-heating-pid-output"
+ "@id": "urn:ex/vav-533-colder-supply-air-requests"
},
{
- "@id": "urn:ex/vav-517-more-heat-requests"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-517-air-out"
+ "@id": "urn:ex/vav-533-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/zone-115-window-switch-on-off",
+ "@id": "urn:ex/vav-536-colder-supply-air-requests",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-537",
+ "@id": "urn:ex/room-204-in",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-537-air-in"
- },
- {
- "@id": "urn:ex/vav-537-air-out"
- },
- {
- "@id": "urn:ex/vav-537-hot-water-in"
- },
- {
- "@id": "urn:ex/vav-537-hot-water-out"
+ "@id": "urn:ex/connection-to-room-204-205"
}
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-537-damper"
- },
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-503-discharge-air-flow-sensor",
+ "@type": [
+ "http://data.ashrae.org/standard223#Sensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-537-reheat-coil"
- },
+ "@id": "urn:ex/vav-503-air-in"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-537-reheat-coil-valve"
+ "@id": "urn:ex/vav-503-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/zone-206-cooling-setpoint",
+ "@id": "urn:ex/zone-312-occupancy-override",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-303-304-306-occupancy-override",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
]
},
{
- "@id": "urn:ex/vav-524-reheat-coil-water-out",
+ "@id": "urn:ex/vav-526-damper-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-524-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-526-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-526-colder-supply-air-requests"
+ },
+ {
+ "@id": "urn:ex/vav-526-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/zone-106-107-window-switch-on-off",
+ "@id": "urn:ex/vav-527-discharge-air-flow",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-528-cooling-pid-output",
+ "@id": "urn:ex/vav-529-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/vav-529-hot-water-in-connection"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-529-hot-water-in"
}
]
},
{
- "@id": "urn:ex/vav-512",
+ "@id": "urn:ex/vav-528-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-512-air-in"
+ "@id": "urn:ex/vav-528-reheat-coil-air-in"
},
{
- "@id": "urn:ex/vav-512-air-out"
+ "@id": "urn:ex/vav-528-reheat-coil-air-out"
},
{
- "@id": "urn:ex/vav-512-hot-water-in"
+ "@id": "urn:ex/vav-528-reheat-coil-water-in"
},
{
- "@id": "urn:ex/vav-512-hot-water-out"
+ "@id": "urn:ex/vav-528-reheat-coil-water-out"
}
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/vav-512-damper"
- },
- {
- "@id": "urn:ex/vav-512-reheat-coil"
- },
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "urn:ex/vav-512-reheat-coil-valve"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/zone-211-occupancy",
+ "@id": "urn:ex/zone-215-occupancy-override",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
]
},
{
- "@id": "urn:ex/vav-525-more-heat-requests",
+ "@id": "urn:ex/zone-115-occupancy",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
]
},
{
- "@id": "urn:ex/vav-514-reheat-coil-water-out",
+ "@id": "urn:ex/vav-537-hot-water-in-connection",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-514-pipe-hot-water-return-before-valve"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -9518,259 +9434,197 @@
]
},
{
- "@id": "urn:ex/vav-530-reheat-coil-valve-out",
+ "@id": "urn:ex/office-ahu-pipe-chilled-water-return-before-valve",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-530-hot-water-out-connection"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-530-hot-water-out"
- }
]
},
{
- "@id": "urn:ex/vav-518-heating-pid-output",
+ "@id": "urn:ex/office-ahu-sa-fan-speed-status",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-532-reheat-coil-air-in",
+ "@id": "urn:ex/vav-524-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-532-duct-after-damper"
+ "@id": "urn:ex/vav-524-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-530",
+ "@id": "urn:ex/room-202",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-530-air-in"
- },
- {
- "@id": "urn:ex/vav-530-air-out"
- },
- {
- "@id": "urn:ex/vav-530-hot-water-in"
- },
- {
- "@id": "urn:ex/vav-530-hot-water-out"
- }
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/vav-530-damper"
- },
- {
- "@id": "urn:ex/vav-530-reheat-coil"
- },
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "urn:ex/vav-530-reheat-coil-valve"
+ "@id": "urn:ex/room-202-hvac-domain"
}
]
},
{
- "@id": "urn:ex/office-ahu-colder-chilled-water-requests",
+ "@id": "urn:ex/vav-515-reheat-coil-valve-out",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/vav-515-hot-water-out-connection"
}
- ]
- },
- {
- "@id": "urn:ex/vav-522-discharge-air-temp-setpoint",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-515-hot-water-out"
}
]
},
{
- "@id": "urn:ex/zone-212-temp-sensor",
+ "@id": "urn:ex/vav-521-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-212-hvac-domain"
+ "@id": "urn:ex/vav-521-duct-after-damper"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-212-temp"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-521-colder-supply-air-requests"
+ },
+ {
+ "@id": "urn:ex/vav-521-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/zone-206-co2-sensor",
+ "@id": "urn:ex/zone-116-117-occupancy-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/room-206-hvac-domain"
+ "@id": "urn:ex/room-116-hvac-domain"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/zone-206-co2-concentration"
+ "@id": "urn:ex/zone-116-117-occupancy"
}
]
},
{
- "@id": "urn:ex/vav-532-discharge-air-temp-sensor",
+ "@id": "urn:ex/vav-516-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-532-air-out"
+ "@id": "urn:ex/vav-516-reheat-coil-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-516-reheat-coil-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-516-reheat-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-516-reheat-coil-water-out"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "urn:ex/vav-532-discharge-air-temp"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/office-ahu-chilled-water-out",
+ "@id": "urn:ex/vav-505-damper-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-chilled-water-out-connection"
+ "@id": "urn:ex/vav-505-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/zone-106-107-occupancy",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-508-colder-supply-air-requests",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "@id": "urn:ex/vav-505-colder-supply-air-requests"
+ },
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/vav-505-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/vav-501-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-532-reheat-coil-water-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-501-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-532-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
- ]
- },
- {
- "@id": "urn:ex/room-106-hvac-domain",
- "@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/room-106-in"
- },
- {
- "@id": "urn:ex/room-106-out"
- }
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "urn:ex/vav-532-hot-water-in"
}
]
},
{
- "@id": "urn:ex/vav-520-damper-command",
+ "@id": "urn:ex/zone-204-205-cooling-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
- {
- "@id": "http://qudt.org/vocab/unit/PERCENT"
- }
- ]
- },
- {
- "@id": "urn:ex/zone-115-temp",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
"@id": "http://qudt.org/vocab/quantitykind/Temperature"
@@ -9783,78 +9637,89 @@
]
},
{
- "@id": "urn:ex/vav-539-reheat-coil-valve-command",
+ "@id": "urn:ex/vav-524-colder-supply-air-requests",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-501-damper-in",
+ "@id": "urn:ex/zone-312",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/room-312-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-501-air-in"
+ "@id": "urn:ex/zone-312-cooling-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-312-heating-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-312-occupancy"
+ },
+ {
+ "@id": "urn:ex/zone-312-occupancy-override"
+ },
+ {
+ "@id": "urn:ex/zone-312-temp"
+ },
+ {
+ "@id": "urn:ex/zone-312-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-532-damper-position",
+ "@id": "urn:ex/zone-210-occupancy-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/room-210-hvac-domain"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/zone-210-occupancy"
}
]
},
{
- "@id": "urn:ex/vav-535-discharge-air-flow-sensor",
+ "@id": "urn:ex/vav-517-hot-water-in",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-535-air-in"
+ "@id": "urn:ex/vav-517-hot-water-in-connection"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-535-discharge-air-flow"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-533-damper-command",
+ "@id": "urn:ex/vav-540-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -9868,140 +9733,114 @@
]
},
{
- "@id": "urn:ex/room-115-hvac-domain",
+ "@id": "urn:ex/room-213-in",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-115-in"
- },
- {
- "@id": "urn:ex/room-115-out"
+ "@id": "urn:ex/connection-to-room-213"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-510-reheat-coil-valve-out",
+ "@id": "urn:ex/vav-525-reheat-coil-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-510-hot-water-out-connection"
+ "@id": "urn:ex/connection-to-room-211"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-510-hot-water-out"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/vav-502",
- "@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-502-air-in"
- },
- {
- "@id": "urn:ex/vav-502-air-out"
- },
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-502-hot-water-in"
+ "@id": "urn:ex/vav-525-heating-pid-output"
},
{
- "@id": "urn:ex/vav-502-hot-water-out"
+ "@id": "urn:ex/vav-525-more-heat-requests"
}
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/vav-502-damper"
- },
- {
- "@id": "urn:ex/vav-502-reheat-coil"
- },
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-502-reheat-coil-valve"
+ "@id": "urn:ex/vav-525-air-out"
}
]
},
{
- "@id": "urn:ex/zone-211-heating-setpoint",
+ "@id": "urn:ex/vav-518-reheat-coil-valve-position",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/office-ahu-air-filter-out",
+ "@id": "urn:ex/vav-519-discharge-air-flow-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/office-ahu-duct-after-air-filter"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-504-duct-after-damper",
+ "@id": "urn:ex/vav-502-hot-water-out-connection",
"@type": [
"http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/zone-208-209-window-switch-on-off",
+ "@id": "urn:ex/vav-513-hot-water-out-connection",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/room-306-out",
+ "@id": "urn:ex/vav-507-air-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -10011,74 +9850,23 @@
]
},
{
- "@id": "urn:ex/office-ahu",
+ "@id": "urn:ex/vav-516-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#AirHandlingUnit"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/office-ahu-chilled-water-in"
- },
- {
- "@id": "urn:ex/office-ahu-chilled-water-out"
- },
- {
- "@id": "urn:ex/office-ahu-ea-out"
- },
- {
- "@id": "urn:ex/office-ahu-hot-water-in"
- },
- {
- "@id": "urn:ex/office-ahu-hot-water-out"
- },
- {
- "@id": "urn:ex/office-ahu-oa-in"
- },
- {
- "@id": "urn:ex/office-ahu-ra-in"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/office-ahu-sa-out"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/office-ahu-air-filter"
- },
- {
- "@id": "urn:ex/office-ahu-clg-coil"
- },
- {
- "@id": "urn:ex/office-ahu-clg-coil-valve"
- },
- {
- "@id": "urn:ex/office-ahu-ea-damper"
- },
- {
- "@id": "urn:ex/office-ahu-htg-coil"
- },
- {
- "@id": "urn:ex/office-ahu-htg-coil-valve"
- },
- {
- "@id": "urn:ex/office-ahu-moisture-eliminator"
- },
- {
- "@id": "urn:ex/office-ahu-oa-damper"
- },
- {
- "@id": "urn:ex/office-ahu-ra-damper"
- },
- {
- "@id": "urn:ex/office-ahu-ra-fan"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/office-ahu-sa-fan"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/connection-to-room-102",
+ "@id": "urn:ex/vav-509-duct-after-damper",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Duct"
@@ -10090,35 +9878,54 @@
]
},
{
- "@id": "urn:ex/vav-517-discharge-air-temp",
+ "@id": "urn:ex/vav-502-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ "@id": "urn:ex/vav-502-reheat-coil-valve-in"
+ },
+ {
+ "@id": "urn:ex/vav-502-reheat-coil-valve-out"
}
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-502-reheat-coil-valve-command"
+ },
+ {
+ "@id": "urn:ex/vav-502-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-513-reheat-coil-water-out",
+ "@id": "urn:ex/room-106-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-513-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-504-pipe-hot-water-return-before-valve",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -10127,87 +9934,74 @@
]
},
{
- "@id": "urn:ex/vav-524-damper",
+ "@id": "urn:ex/vav-539-reheat-coil-air-out",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-524-damper-in"
- },
+ "@id": "urn:ex/connection-to-room-214"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-524-damper-out"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-524-damper-command"
+ "@id": "urn:ex/vav-539-heating-pid-output"
},
{
- "@id": "urn:ex/vav-524-damper-position"
- }
- ]
- },
- {
- "@id": "urn:ex/zone-211-temp-sensor",
- "@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:ex/room-211-hvac-domain"
+ "@id": "urn:ex/vav-539-more-heat-requests"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/zone-211-temp"
+ "@id": "urn:ex/vav-539-air-out"
}
]
},
{
- "@id": "urn:ex/zone-105-cooling-setpoint",
+ "@id": "urn:ex/office-ahu-sa-fan-speed-cmd",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/room-212-hvac-domain",
+ "@id": "urn:ex/vav-538-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/room-212-in"
- },
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/room-212-out"
+ "@id": "urn:ex/vav-538-reheat-coil-valve"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "urn:ex/vav-538-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/vav-518-reheat-coil-air-out",
+ "@id": "urn:ex/vav-535-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-202"
+ "@id": "urn:ex/connection-to-room-311"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -10217,168 +10011,122 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-518-heating-pid-output"
+ "@id": "urn:ex/vav-535-discharge-air-flow"
},
{
- "@id": "urn:ex/vav-518-more-heat-requests"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-518-air-out"
- }
- ]
- },
- {
- "@id": "urn:ex/zone-113-window-switch-on-off",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "@id": "urn:ex/vav-535-discharge-air-flow-setpoint"
+ },
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-538-more-heat-requests",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "@id": "urn:ex/vav-535-discharge-air-temp"
+ },
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/vav-535-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/vav-528-reheat-coil-water-in",
+ "@id": "urn:ex/vav-517-cooling-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-528-hot-water-in-connection"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-528-hot-water-in"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-507-discharge-air-flow-sensor",
+ "@id": "urn:ex/vav-532-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-507-air-in"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-507-discharge-air-flow"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-522-reheat-coil-water-in",
+ "@id": "urn:ex/zone-212-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-522-hot-water-in-connection"
- }
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-522-hot-water-in"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/zone-206-temp-sensor",
+ "@id": "urn:ex/room-206",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#encloses": [
{
"@id": "urn:ex/room-206-hvac-domain"
}
- ],
- "http://data.ashrae.org/standard223#observes": [
- {
- "@id": "urn:ex/zone-206-temp"
- }
]
},
{
- "@id": "urn:ex/vav-513-reheat-coil-valve-out",
+ "@id": "urn:ex/vav-503-reheat-coil-valve-position",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-513-hot-water-out-connection"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-513-hot-water-out"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/office-ahu-moisture-eliminator-in",
+ "@id": "urn:ex/zone-303-304-306-occupancy-sensor",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/office-ahu-oa-in-connection"
- }
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/room-303-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/office-ahu-oa-in"
+ "@id": "urn:ex/zone-303-304-306-occupancy"
}
]
},
{
- "@id": "urn:ex/vav-539-reheat-coil-valve",
+ "@id": "urn:ex/vav-522-reheat-coil-valve",
"@type": [
"http://data.ashrae.org/standard223#Valve",
"http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-539-reheat-coil-valve-in"
+ "@id": "urn:ex/vav-522-reheat-coil-valve-in"
},
{
- "@id": "urn:ex/vav-539-reheat-coil-valve-out"
+ "@id": "urn:ex/vav-522-reheat-coil-valve-out"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -10388,218 +10136,238 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-539-reheat-coil-valve-command"
+ "@id": "urn:ex/vav-522-reheat-coil-valve-command"
},
{
- "@id": "urn:ex/vav-539-reheat-coil-valve-position"
+ "@id": "urn:ex/vav-522-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-525-discharge-air-temp-sensor",
+ "@id": "urn:ex/zone-112-114-temp-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-525-air-out"
+ "@id": "urn:ex/room-112-hvac-domain"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-525-discharge-air-temp"
+ "@id": "urn:ex/zone-112-114-temp"
}
]
},
{
- "@id": "urn:ex/zone-112-114-window-switch-on-off",
+ "@id": "urn:ex/room-102-out",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-517-cooling-pid-output",
+ "@id": "urn:ex/zone-203",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/room-203-hvac-domain"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
- ]
- },
- {
- "@id": "urn:ex/room-106",
- "@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/room-106-hvac-domain"
+ "@id": "urn:ex/zone-203-cooling-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-203-heating-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-203-occupancy"
+ },
+ {
+ "@id": "urn:ex/zone-203-occupancy-override"
+ },
+ {
+ "@id": "urn:ex/zone-203-temp"
+ },
+ {
+ "@id": "urn:ex/zone-203-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-507-reheat-coil-air-in",
+ "@id": "urn:ex/office-ahu-oa-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/vav-507-duct-after-damper"
+ "@id": "urn:ex/office-ahu-oa-damper"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/office-ahu-oa-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-535-air-in",
+ "@id": "urn:ex/vav-534-discharge-air-temp",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-540-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-506-reheat-coil-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-540-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-506-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-537-discharge-air-flow-setpoint",
+ "@id": "urn:ex/zone-113-occupancy-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:ex/room-113-hvac-domain"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:ex/zone-113-occupancy"
}
]
},
{
- "@id": "urn:ex/room-313",
+ "@id": "urn:ex/zone-213-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/room-313-hvac-domain"
+ "@id": "urn:ex/room-213-hvac-domain"
}
- ]
- },
- {
- "@id": "urn:ex/vav-537-hot-water-in-connection",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/zone-213-temp"
}
]
},
{
- "@id": "urn:ex/vav-525-reheat-coil-air-in",
+ "@id": "urn:ex/vav-532-damper-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-525-duct-after-damper"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-532-air-in"
+ }
]
},
{
- "@id": "urn:ex/zone-207-temp",
+ "@id": "urn:ex/vav-535-reheat-coil-valve-position",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/room-209-hvac-domain",
+ "@id": "urn:ex/vav-526-heating-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/room-209-in"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-209-out"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/room-308",
+ "@id": "urn:ex/vav-507-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-308-hvac-domain"
+ "@id": "urn:ex/vav-507-hot-water-out-connection"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-503-cooling-pid-output",
+ "@id": "urn:ex/vav-537-heating-pid-output",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -10615,33 +10383,30 @@
]
},
{
- "@id": "urn:ex/vav-515-reheat-coil",
+ "@id": "urn:ex/vav-534-more-heat-requests",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-515-reheat-coil-air-in"
- },
- {
- "@id": "urn:ex/vav-515-reheat-coil-air-out"
- },
- {
- "@id": "urn:ex/vav-515-reheat-coil-water-in"
- },
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-515-reheat-coil-water-out"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-511-duct-after-damper",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/zone-213-cooling-setpoint",
+ "@id": "urn:ex/zone-210-heating-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -10657,60 +10422,62 @@
]
},
{
- "@id": "urn:ex/vav-540-reheat-coil-valve-position",
+ "@id": "urn:ex/vav-512-damper",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-512-damper-in"
+ },
+ {
+ "@id": "urn:ex/vav-512-damper-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/vav-512-damper-command"
+ },
+ {
+ "@id": "urn:ex/vav-512-damper-position"
}
]
},
{
- "@id": "urn:ex/vav-509-discharge-air-temp",
+ "@id": "urn:ex/vav-518-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-518-pipe-hot-water-return-before-valve"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/zone-314-occupancy-sensor",
+ "@id": "urn:ex/zone-110-occupancy-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/room-314-hvac-domain"
+ "@id": "urn:ex/room-110-hvac-domain"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/zone-314-occupancy"
+ "@id": "urn:ex/zone-110-occupancy"
}
]
},
{
- "@id": "urn:ex/vav-539-air-in",
+ "@id": "urn:ex/vav-511-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -10726,59 +10493,57 @@
]
},
{
- "@id": "urn:ex/vav-504-reheat-coil",
+ "@id": "urn:ex/vav-517-reheat-coil-air-in",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-504-reheat-coil-air-in"
- },
- {
- "@id": "urn:ex/vav-504-reheat-coil-air-out"
- },
- {
- "@id": "urn:ex/vav-504-reheat-coil-water-in"
- },
- {
- "@id": "urn:ex/vav-504-reheat-coil-water-out"
+ "@id": "urn:ex/vav-517-duct-after-damper"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-517-damper-out",
+ "@id": "urn:ex/vav-506-hot-water-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-517-duct-after-damper"
+ "@id": "urn:ex/vav-506-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/room-114-in",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-517-colder-supply-air-requests"
- },
+ "@id": "urn:ex/connection-to-room-112-114"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-517-cooling-pid-output"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-512-damper-command",
+ "@id": "urn:ex/office-ahu-ea-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -10792,30 +10557,30 @@
]
},
{
- "@id": "urn:ex/office-ahu-oa-damper-position",
+ "@id": "urn:ex/vav-501-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-501-hot-water-out-connection"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/zone-313",
+ "@id": "urn:ex/zone-207",
"@type": [
"http://data.ashrae.org/standard223#Zone",
"http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
"http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/room-313-hvac-domain"
+ "@id": "urn:ex/room-207-hvac-domain"
}
],
"http://data.ashrae.org/standard223#hasDomain": [
@@ -10825,43 +10590,27 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/zone-313-cooling-setpoint"
+ "@id": "urn:ex/zone-207-cooling-setpoint"
},
{
- "@id": "urn:ex/zone-313-heating-setpoint"
+ "@id": "urn:ex/zone-207-heating-setpoint"
},
{
- "@id": "urn:ex/zone-313-occupancy"
+ "@id": "urn:ex/zone-207-occupancy"
},
{
- "@id": "urn:ex/zone-313-occupancy-override"
+ "@id": "urn:ex/zone-207-occupancy-override"
},
{
- "@id": "urn:ex/zone-313-temp"
+ "@id": "urn:ex/zone-207-temp"
},
{
- "@id": "urn:ex/zone-313-window-switch-on-off"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-533-reheat-coil-water-out",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-533-pipe-hot-water-return-before-valve"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/zone-207-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-539-discharge-air-temp-setpoint",
+ "@id": "urn:ex/zone-115-cooling-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -10877,301 +10626,310 @@
]
},
{
- "@id": "urn:ex/room-203-out",
+ "@id": "urn:ex/zone-215",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/room-215-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
- ]
- },
- {
- "@id": "urn:ex/vav-529-damper",
- "@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-529-damper-in"
+ "@id": "urn:ex/zone-215-cooling-setpoint"
},
{
- "@id": "urn:ex/vav-529-damper-out"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "@id": "urn:ex/zone-215-heating-setpoint"
+ },
{
- "@id": "urn:ex/vav-529-damper-command"
+ "@id": "urn:ex/zone-215-occupancy"
},
{
- "@id": "urn:ex/vav-529-damper-position"
+ "@id": "urn:ex/zone-215-occupancy-override"
+ },
+ {
+ "@id": "urn:ex/zone-215-temp"
+ },
+ {
+ "@id": "urn:ex/zone-215-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/zone-201-occupancy-sensor",
+ "@id": "urn:ex/vav-521-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-201-hvac-domain"
+ "@id": "urn:ex/vav-521-pipe-hot-water-return-before-valve"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-201-occupancy"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-509-colder-supply-air-requests",
+ "@id": "urn:ex/room-116",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/room-116-hvac-domain"
}
]
},
{
- "@id": "urn:ex/vav-514-reheat-coil-valve",
+ "@id": "urn:ex/vav-532-air-out",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-514-reheat-coil-valve-in"
- },
- {
- "@id": "urn:ex/vav-514-reheat-coil-valve-out"
+ "@id": "urn:ex/connection-to-room-309-310"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-514-reheat-coil-valve-command"
+ "@id": "urn:ex/vav-532-discharge-air-flow"
},
{
- "@id": "urn:ex/vav-514-reheat-coil-valve-position"
+ "@id": "urn:ex/vav-532-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-532-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-532-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/office-ahu-duct-after-ra-fan",
+ "@id": "urn:ex/vav-539-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-539-air-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:ex/vav-539-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/vav-501-air-out",
+ "@id": "urn:ex/zone-101",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/connection-to-room-102"
+ "@id": "urn:ex/room-101-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-501-discharge-air-flow"
+ "@id": "urn:ex/zone-101-building-static-pressure"
},
{
- "@id": "urn:ex/vav-501-discharge-air-flow-setpoint"
+ "@id": "urn:ex/zone-101-building-static-pressure-setpoint"
},
{
- "@id": "urn:ex/vav-501-discharge-air-temp"
+ "@id": "urn:ex/zone-101-co2-concentration"
},
{
- "@id": "urn:ex/vav-501-discharge-air-temp-setpoint"
+ "@id": "urn:ex/zone-101-co2-concentration-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-101-cooling-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-101-heating-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-101-occupancy"
+ },
+ {
+ "@id": "urn:ex/zone-101-occupancy-override"
+ },
+ {
+ "@id": "urn:ex/zone-101-temp"
+ },
+ {
+ "@id": "urn:ex/zone-101-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-511-reheat-coil",
+ "@id": "urn:ex/zone-116-117-occupancy-override",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ {
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-509",
+ "@type": [
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-511-reheat-coil-air-in"
+ "@id": "urn:ex/vav-509-air-in"
},
{
- "@id": "urn:ex/vav-511-reheat-coil-air-out"
+ "@id": "urn:ex/vav-509-air-out"
},
{
- "@id": "urn:ex/vav-511-reheat-coil-water-in"
+ "@id": "urn:ex/vav-509-hot-water-in"
},
{
- "@id": "urn:ex/vav-511-reheat-coil-water-out"
+ "@id": "urn:ex/vav-509-hot-water-out"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "urn:ex/vav-509-damper"
+ },
+ {
+ "@id": "urn:ex/vav-509-reheat-coil"
+ },
+ {
+ "@id": "urn:ex/vav-509-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/vav-511-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-508-damper-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-511-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/vav-531-hot-water-in-connection",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-508-air-in"
}
]
},
{
- "@id": "urn:ex/vav-525-heating-pid-output",
+ "@id": "urn:ex/vav-519-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
- }
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "urn:ex/vav-519-air-out"
}
- ]
- },
- {
- "@id": "urn:ex/vav-511-pipe-hot-water-return-before-valve",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-519-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/zone-101-occupancy-sensor",
+ "@id": "urn:ex/vav-504-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-101-hvac-domain"
+ "@id": "urn:ex/vav-504-pipe-hot-water-return-before-valve"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-101-occupancy"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-517-reheat-coil-valve-actuator",
+ "@id": "urn:ex/zone-113-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-517-reheat-coil-valve"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-517-reheat-coil-valve-command"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/room-314-in",
+ "@id": "urn:ex/vav-533-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-314"
+ "@id": "urn:ex/vav-533-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/office-ahu-ea-damper",
+ "@id": "urn:ex/room-111-out",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-ea-damper-in"
- },
- {
- "@id": "urn:ex/office-ahu-ea-damper-out"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/office-ahu-ea-damper-command"
- },
- {
- "@id": "urn:ex/office-ahu-ea-damper-position"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Exhaust"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-534-discharge-air-temp",
+ "@id": "urn:ex/vav-524-discharge-air-flow",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -11182,19 +10940,24 @@
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-540-discharge-air-temp-setpoint",
+ "@id": "urn:ex/vav-522-discharge-air-temp",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasAspect": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -11208,95 +10971,128 @@
]
},
{
- "@id": "urn:ex/vav-512-damper-position",
+ "@id": "urn:ex/vav-518-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-518-duct-after-damper"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-518-colder-supply-air-requests"
+ },
+ {
+ "@id": "urn:ex/vav-518-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/vav-526-hot-water-out",
+ "@id": "urn:ex/vav-511-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-526-hot-water-out-connection"
+ "@id": "urn:ex/vav-511-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-511-hot-water-in"
+ }
]
},
{
- "@id": "urn:ex/vav-527-damper-in",
+ "@id": "urn:ex/vav-513-reheat-coil-valve-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-513-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-527-air-in"
+ "@id": "urn:ex/vav-513-hot-water-out"
}
]
},
{
- "@id": "urn:ex/vav-519-reheat-coil-valve",
+ "@id": "urn:ex/zone-104",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-519-reheat-coil-valve-in"
- },
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/vav-519-reheat-coil-valve-out"
+ "@id": "urn:ex/room-104-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-519-reheat-coil-valve-command"
+ "@id": "urn:ex/zone-104-cooling-setpoint"
},
{
- "@id": "urn:ex/vav-519-reheat-coil-valve-position"
+ "@id": "urn:ex/zone-104-heating-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-104-occupancy"
+ },
+ {
+ "@id": "urn:ex/zone-104-occupancy-override"
+ },
+ {
+ "@id": "urn:ex/zone-104-temp"
+ },
+ {
+ "@id": "urn:ex/zone-104-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-510-discharge-air-temp",
+ "@id": "urn:ex/vav-508-reheat-coil-valve-command",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-302-temp",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -11310,89 +11106,96 @@
]
},
{
- "@id": "urn:ex/vav-532-air-out",
+ "@id": "urn:ex/vav-503-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-309-310"
+ "@id": "urn:ex/vav-503-reheat-coil-valve-in"
+ },
+ {
+ "@id": "urn:ex/vav-503-reheat-coil-valve-out"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-532-discharge-air-flow"
- },
- {
- "@id": "urn:ex/vav-532-discharge-air-flow-setpoint"
- },
- {
- "@id": "urn:ex/vav-532-discharge-air-temp"
+ "@id": "urn:ex/vav-503-reheat-coil-valve-command"
},
{
- "@id": "urn:ex/vav-532-discharge-air-temp-setpoint"
+ "@id": "urn:ex/vav-503-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/room-109",
+ "@id": "urn:ex/room-101",
"@type": [
"http://data.ashrae.org/standard223#PhysicalSpace"
],
"http://data.ashrae.org/standard223#encloses": [
{
- "@id": "urn:ex/room-109-hvac-domain"
+ "@id": "urn:ex/room-101-hvac-domain"
}
]
},
{
- "@id": "urn:ex/room-314-hvac-domain",
+ "@id": "urn:ex/vav-532-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-314-in"
- },
+ "@id": "urn:ex/vav-532-hot-water-out-connection"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/room-314-out"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-539-duct-after-damper",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/zone-118-temp",
+ "@id": "urn:ex/vav-502-heating-pid-output",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-521-reheat-coil-valve-out",
+ "@id": "urn:ex/vav-528-reheat-coil-valve-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-521-hot-water-out-connection"
+ "@id": "urn:ex/vav-528-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -11402,56 +11205,71 @@
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-521-hot-water-out"
+ "@id": "urn:ex/vav-528-hot-water-out"
}
]
},
{
- "@id": "urn:ex/vav-527-reheat-coil-valve-in",
+ "@id": "urn:ex/zone-208-209",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/vav-527-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/room-208-hvac-domain"
+ },
+ {
+ "@id": "urn:ex/room-209-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/zone-208-209-cooling-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-208-209-heating-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-208-209-occupancy"
+ },
+ {
+ "@id": "urn:ex/zone-208-209-occupancy-override"
+ },
+ {
+ "@id": "urn:ex/zone-208-209-temp"
+ },
+ {
+ "@id": "urn:ex/zone-208-209-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-503-discharge-air-temp",
+ "@id": "urn:ex/vav-536-discharge-air-flow-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/room-109-in",
+ "@id": "urn:ex/office-ahu-connection-to-vavs",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/connection-to-room-109"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -11460,13 +11278,13 @@
]
},
{
- "@id": "urn:ex/vav-502-reheat-coil-valve-in",
+ "@id": "urn:ex/office-ahu-hot-water-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-502-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/office-ahu-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -11476,386 +11294,376 @@
]
},
{
- "@id": "urn:ex/room-303-hvac-domain",
+ "@id": "urn:ex/vav-506-reheat-coil-valve-command",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-303-in"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/room-303-out"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/room-212",
+ "@type": [
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "urn:ex/room-212-hvac-domain"
}
]
},
{
- "@id": "urn:ex/zone-103-temp",
+ "@id": "urn:ex/vav-504-discharge-air-flow-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-508-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/vav-531-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-531-reheat-coil-valve-in"
+ },
+ {
+ "@id": "urn:ex/vav-531-reheat-coil-valve-out"
}
- ]
- },
- {
- "@id": "urn:ex/vav-512-hot-water-in-connection",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-531-reheat-coil-valve-command"
+ },
+ {
+ "@id": "urn:ex/vav-531-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-512-reheat-coil-valve-out",
+ "@id": "urn:ex/vav-505-discharge-air-temp",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/vav-512-hot-water-out-connection"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-512-hot-water-out"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-510-reheat-coil-air-out",
+ "@id": "urn:ex/vav-504-reheat-coil-valve-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-111"
+ "@id": "urn:ex/vav-504-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-510-heating-pid-output"
- },
- {
- "@id": "urn:ex/vav-510-more-heat-requests"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-510-air-out"
+ "@id": "urn:ex/vav-504-hot-water-out"
}
]
},
{
- "@id": "urn:ex/zone-203",
+ "@id": "urn:ex/vav-511-hot-water-in-connection",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
- ],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/room-203-hvac-domain"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-526-hot-water-in-connection",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/zone-203-cooling-setpoint"
- },
- {
- "@id": "urn:ex/zone-203-heating-setpoint"
- },
- {
- "@id": "urn:ex/zone-203-occupancy"
- },
- {
- "@id": "urn:ex/zone-203-occupancy-override"
- },
- {
- "@id": "urn:ex/zone-203-temp"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-203-window-switch-on-off"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-538-reheat-coil-valve",
+ "@id": "urn:ex/vav-509-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-538-reheat-coil-valve-in"
- },
- {
- "@id": "urn:ex/vav-538-reheat-coil-valve-out"
+ "@id": "urn:ex/vav-509-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-538-reheat-coil-valve-command"
- },
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-538-reheat-coil-valve-position"
+ "@id": "urn:ex/vav-509-hot-water-in"
}
]
},
{
- "@id": "urn:ex/vav-504-reheat-coil-valve-actuator",
+ "@id": "urn:ex/vav-537-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-504-reheat-coil-valve"
+ "@id": "urn:ex/vav-537-pipe-hot-water-return-before-valve"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-504-reheat-coil-valve-command"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-513-reheat-coil-valve-command",
+ "@id": "urn:ex/vav-509-pipe-hot-water-return-before-valve",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-531-reheat-coil-air-out",
+ "@id": "urn:ex/vav-524-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/connection-to-room-307-308"
+ "@id": "urn:ex/vav-524-air-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-524-discharge-air-temp"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-501-colder-supply-air-requests",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-531-heating-pid-output"
- },
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-531-more-heat-requests"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-517-more-heat-requests",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-531-air-out"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-501-damper-actuator",
+ "@id": "urn:ex/office-ahu-chilled-water-in",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-501-damper"
+ "@id": "urn:ex/office-ahu-chilled-water-in-connection"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-501-damper-command"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/room-303",
+ "@id": "urn:ex/vav-516-heating-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-303-hvac-domain"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-515-damper-command",
+ "@id": "urn:ex/vav-508-discharge-air-temp-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-513-damper-command",
+ "@id": "urn:ex/vav-513-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-513-reheat-coil-valve"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/vav-513-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/vav-511-air-out",
+ "@id": "urn:ex/vav-510-air-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-112-114"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-118-occupancy-override",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-511-discharge-air-flow"
- },
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-511-discharge-air-flow-setpoint"
- },
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-514-discharge-air-flow-sensor",
+ "@type": [
+ "http://data.ashrae.org/standard223#Sensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-511-discharge-air-temp"
- },
+ "@id": "urn:ex/vav-514-air-in"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-511-discharge-air-temp-setpoint"
+ "@id": "urn:ex/vav-514-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/vav-531-damper",
+ "@id": "urn:ex/zone-313-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-531-damper-in"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-531-damper-out"
+ "@id": "urn:ex/room-313-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-531-damper-command"
- },
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-531-damper-position"
+ "@id": "urn:ex/zone-313-temp"
}
]
},
{
- "@id": "urn:ex/office-ahu-clg-coil",
+ "@id": "urn:ex/vav-522-air-in",
"@type": [
- "http://data.ashrae.org/standard223#CoolingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#ChilledWaterCoil"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-clg-coil-air-in"
- },
- {
- "@id": "urn:ex/office-ahu-clg-coil-air-out"
- },
- {
- "@id": "urn:ex/office-ahu-clg-coil-water-in"
- },
- {
- "@id": "urn:ex/office-ahu-clg-coil-water-out"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Cooling"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-521-damper-in",
+ "@id": "urn:ex/vav-537-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-537-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -11863,93 +11671,114 @@
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-521-air-in"
+ "@id": "urn:ex/vav-537-colder-supply-air-requests"
+ },
+ {
+ "@id": "urn:ex/vav-537-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/vav-526-cooling-pid-output",
+ "@id": "urn:ex/room-312-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/room-312-in"
+ },
+ {
+ "@id": "urn:ex/room-312-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-520-reheat-coil-valve-actuator",
+ "@id": "urn:ex/vav-524-reheat-coil-valve-position",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-520-reheat-coil-valve"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-520-reheat-coil-valve-command"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/room-202-hvac-domain",
+ "@id": "urn:ex/vav-509-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/room-202-in"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/room-202-out"
+ "@id": "urn:ex/vav-509-air-out"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "urn:ex/vav-509-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/vav-528-discharge-air-temp",
+ "@id": "urn:ex/office-ahu-oa-damper",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ "@id": "urn:ex/office-ahu-oa-damper-in"
+ },
+ {
+ "@id": "urn:ex/office-ahu-oa-damper-out"
}
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/office-ahu-oa-damper-command"
+ },
+ {
+ "@id": "urn:ex/office-ahu-oa-damper-position"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Role-Economizer"
+ },
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Outside"
}
]
},
{
- "@id": "urn:ex/room-215-in",
+ "@id": "urn:ex/connection-to-room-116-117",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/connection-to-room-215"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-503-duct-after-damper",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -11958,29 +11787,35 @@
]
},
{
- "@id": "urn:ex/vav-535-damper-actuator",
+ "@id": "urn:ex/zone-116-117-occupancy",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-535-damper"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-529-colder-supply-air-requests",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-535-damper-command"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-516-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-512-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-516-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-512-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -11990,34 +11825,45 @@
]
},
{
- "@id": "urn:ex/vav-510-damper-in",
+ "@id": "urn:ex/room-310-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/connection-to-room-309-310"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/office-ahu-ra-fan-out",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-510-air-in"
+ "@id": "urn:ex/office-ahu-duct-after-ra-fan"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-539-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-507-hot-water-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-539-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-507-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -12027,71 +11873,81 @@
]
},
{
- "@id": "urn:ex/vav-507-cooling-pid-output",
+ "@id": "urn:ex/vav-531-discharge-air-flow-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-530-reheat-coil-air-in",
+ "@id": "urn:ex/vav-503-damper-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-530-duct-after-damper"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-503-air-in"
+ }
]
},
{
- "@id": "urn:ex/vav-504",
+ "@id": "urn:ex/zone-108",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/vav-504-air-in"
- },
+ "@id": "urn:ex/room-108-hvac-domain"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:ex/vav-504-air-out"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/zone-108-cooling-setpoint"
},
{
- "@id": "urn:ex/vav-504-hot-water-in"
+ "@id": "urn:ex/zone-108-heating-setpoint"
},
{
- "@id": "urn:ex/vav-504-hot-water-out"
- }
- ],
- "http://data.ashrae.org/standard223#contains": [
+ "@id": "urn:ex/zone-108-occupancy"
+ },
{
- "@id": "urn:ex/vav-504-damper"
+ "@id": "urn:ex/zone-108-occupancy-override"
},
{
- "@id": "urn:ex/vav-504-reheat-coil"
+ "@id": "urn:ex/zone-108-temp"
},
{
- "@id": "urn:ex/vav-504-reheat-coil-valve"
+ "@id": "urn:ex/zone-108-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-513-duct-after-damper",
+ "@id": "urn:ex/vav-516-duct-after-damper",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Duct"
@@ -12103,24 +11959,13 @@
]
},
{
- "@id": "urn:ex/zone-206-window-switch-on-off",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-506-reheat-coil-air-in",
+ "@id": "urn:ex/vav-526-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-506-duct-after-damper"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -12130,121 +11975,110 @@
]
},
{
- "@id": "urn:ex/zone-301-occupancy-override",
+ "@id": "urn:ex/vav-536-cooling-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/office-ahu-sa-fan-in",
+ "@id": "urn:ex/vav-528-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/office-ahu-duct-after-clg-coil"
- }
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-528-air-out"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/office-ahu-sa-flow"
+ "@id": "urn:ex/vav-528-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/vav-508-reheat-coil-valve-command",
+ "@id": "urn:ex/vav-536-hot-water-out-connection",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/zone-312-window-switch-on-off",
+ "@id": "urn:ex/zone-105-occupancy",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
]
},
{
- "@id": "urn:ex/vav-505",
+ "@id": "urn:ex/vav-502-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-505-air-in"
- },
- {
- "@id": "urn:ex/vav-505-air-out"
- },
- {
- "@id": "urn:ex/vav-505-hot-water-in"
- },
- {
- "@id": "urn:ex/vav-505-hot-water-out"
+ "@id": "urn:ex/vav-502-pipe-hot-water-return-before-valve"
}
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/vav-505-damper"
- },
- {
- "@id": "urn:ex/vav-505-reheat-coil"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-505-reheat-coil-valve"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-508-damper",
+ "@id": "urn:ex/vav-537-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/vav-508-damper-in"
- },
+ "@id": "urn:ex/vav-537-damper"
+ }
+ ],
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/vav-508-damper-out"
+ "@id": "urn:ex/vav-537-damper-command"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-213-occupancy-sensor",
+ "@type": [
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-508-damper-command"
- },
+ "@id": "urn:ex/room-213-hvac-domain"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-508-damper-position"
+ "@id": "urn:ex/zone-213-occupancy"
}
]
},
{
- "@id": "urn:ex/room-214-out",
+ "@id": "urn:ex/room-306-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -12260,168 +12094,232 @@
]
},
{
- "@id": "urn:ex/vav-532-discharge-air-temp",
+ "@id": "urn:ex/vav-512-discharge-air-flow-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-510-discharge-air-temp-setpoint",
+ "@id": "urn:ex/zone-102-occupancy",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
]
},
{
- "@id": "urn:ex/vav-516-reheat-coil-water-out",
+ "@id": "urn:ex/vav-504-reheat-coil-air-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-516-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-504-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/room-313-hvac-domain",
+ "@id": "urn:ex/vav-506",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-313-in"
+ "@id": "urn:ex/vav-506-air-in"
},
{
- "@id": "urn:ex/room-313-out"
+ "@id": "urn:ex/vav-506-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-506-hot-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-506-hot-water-out"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "urn:ex/vav-506-damper"
+ },
+ {
+ "@id": "urn:ex/vav-506-reheat-coil"
+ },
+ {
+ "@id": "urn:ex/vav-506-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/vav-538-discharge-air-temp-sensor",
+ "@id": "urn:ex/vav-521-pipe-hot-water-return-before-valve",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-538-air-out"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-104-window-switch-on-off",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-538-discharge-air-temp"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/vav-522-colder-supply-air-requests",
+ "@id": "urn:ex/vav-525-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/vav-525-damper"
+ }
+ ],
+ "http://data.ashrae.org/standard223#commandedByProperty": [
+ {
+ "@id": "urn:ex/vav-525-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-520-more-heat-requests",
+ "@id": "urn:ex/vav-534-hot-water-out-connection",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-502-reheat-coil-valve-actuator",
+ "@id": "urn:ex/vav-516-reheat-coil-valve-actuator",
"@type": [
"http://data.ashrae.org/standard223#Actuator"
],
"http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/vav-502-reheat-coil-valve"
+ "@id": "urn:ex/vav-516-reheat-coil-valve"
}
],
"http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/vav-502-reheat-coil-valve-command"
+ "@id": "urn:ex/vav-516-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/zone-214-cooling-setpoint",
+ "@id": "urn:ex/office-ahu-hot-water-out-connection",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-535-duct-after-damper",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/office-ahu-ra-fan-start-status",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ {
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-528",
+ "@type": [
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-528-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-528-air-out"
+ },
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-528-hot-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-528-hot-water-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-528-damper"
+ },
+ {
+ "@id": "urn:ex/vav-528-reheat-coil"
+ },
+ {
+ "@id": "urn:ex/vav-528-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/room-103-hvac-domain",
+ "@id": "urn:ex/vav-508-hot-water-in",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-103-in"
- },
- {
- "@id": "urn:ex/room-103-out"
+ "@id": "urn:ex/vav-508-hot-water-in-connection"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/zone-314-occupancy-override",
+ "@id": "urn:ex/zone-311-occupancy-override",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
@@ -12432,84 +12330,56 @@
]
},
{
- "@id": "urn:ex/vav-527-reheat-coil-valve",
+ "@id": "urn:ex/vav-531-reheat-coil-air-in",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-527-reheat-coil-valve-in"
- },
- {
- "@id": "urn:ex/vav-527-reheat-coil-valve-out"
+ "@id": "urn:ex/vav-531-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-527-reheat-coil-valve-command"
- },
- {
- "@id": "urn:ex/vav-527-reheat-coil-valve-position"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-535-discharge-air-temp",
+ "@id": "urn:ex/vav-510-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
- ]
- },
- {
- "@id": "urn:ex/vav-516-discharge-air-flow-setpoint",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:ex/vav-510-air-in"
}
]
},
{
- "@id": "urn:ex/office-ahu-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/vav-514-duct-after-damper",
"@type": [
"http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/zone-201-cooling-setpoint",
+ "@id": "urn:ex/zone-105-heating-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -12525,10 +12395,26 @@
]
},
{
- "@id": "urn:ex/zone-116-117-temp",
+ "@id": "urn:ex/zone-104-occupancy-override",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ {
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-509-discharge-air-temp",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
+ "http://data.ashrae.org/standard223#hasAspect": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
+ ],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
"@id": "http://qudt.org/vocab/quantitykind/Temperature"
@@ -12541,146 +12427,103 @@
]
},
{
- "@id": "urn:ex/zone-302",
+ "@id": "urn:ex/vav-539-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-302-hvac-domain"
+ "@id": "urn:ex/vav-539-duct-after-damper"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/zone-302-co2-concentration"
- },
- {
- "@id": "urn:ex/zone-302-co2-concentration-setpoint"
- },
- {
- "@id": "urn:ex/zone-302-cooling-setpoint"
- },
- {
- "@id": "urn:ex/zone-302-heating-setpoint"
- },
- {
- "@id": "urn:ex/zone-302-occupancy"
- },
- {
- "@id": "urn:ex/zone-302-occupancy-override"
- },
- {
- "@id": "urn:ex/zone-302-temp"
+ "@id": "urn:ex/vav-539-colder-supply-air-requests"
},
{
- "@id": "urn:ex/zone-302-window-switch-on-off"
+ "@id": "urn:ex/vav-539-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/vav-519-reheat-coil-water-in",
+ "@id": "urn:ex/vav-501-hot-water-out-connection",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-519-hot-water-in-connection"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-519-hot-water-in"
- }
]
},
{
- "@id": "urn:ex/zone-202-occupancy",
+ "@id": "urn:ex/vav-518-pipe-hot-water-return-before-valve",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/zone-303-304-306-temp",
+ "@id": "urn:ex/zone-109-window-switch-on-off",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/room-301-in",
+ "@id": "urn:ex/vav-519-discharge-air-temp",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/connection-to-room-301"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
- ]
- },
- {
- "@id": "urn:ex/vav-517-reheat-coil-valve-command",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/room-102-in",
+ "@id": "urn:ex/vav-534-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/connection-to-room-102"
+ "@id": "urn:ex/vav-534-air-in"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-534-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/zone-309-310-temp-sensor",
+ "@id": "urn:ex/zone-309-310-occupancy-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
@@ -12691,45 +12534,53 @@
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/zone-309-310-temp"
+ "@id": "urn:ex/zone-309-310-occupancy"
}
]
},
{
- "@id": "urn:ex/zone-307-308-cooling-setpoint",
+ "@id": "urn:ex/vav-504-damper-command",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/room-101",
+ "@id": "urn:ex/room-116-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-101-hvac-domain"
+ "@id": "urn:ex/room-116-in"
+ },
+ {
+ "@id": "urn:ex/room-116-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasDomain": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-516-hot-water-out",
+ "@id": "urn:ex/vav-538-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-516-hot-water-out-connection"
+ "@id": "urn:ex/vav-538-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -12739,83 +12590,103 @@
]
},
{
- "@id": "urn:ex/vav-519-damper-actuator",
+ "@id": "urn:ex/vav-517-reheat-coil-valve-position",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-519-damper"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-519-damper-command"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-529-discharge-air-temp-sensor",
+ "@id": "urn:ex/vav-529",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-529-air-in"
+ },
{
"@id": "urn:ex/vav-529-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-529-hot-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-529-hot-water-out"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/vav-529-discharge-air-temp"
+ "@id": "urn:ex/vav-529-damper"
+ },
+ {
+ "@id": "urn:ex/vav-529-reheat-coil"
+ },
+ {
+ "@id": "urn:ex/vav-529-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/vav-540-reheat-coil-water-in",
+ "@id": "urn:ex/room-305-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-540-hot-water-in-connection"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:ex/room-305-in"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/room-305-out"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:ex/vav-540-hot-water-in"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/room-313-in",
+ "@id": "urn:ex/zone-202-temp",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/connection-to-room-313"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/office-ahu-oa-temp",
+ "@id": "urn:ex/vav-502-colder-supply-air-requests",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Outside"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-539-discharge-air-temp-setpoint",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -12829,81 +12700,99 @@
]
},
{
- "@id": "urn:ex/vav-537-damper-command",
+ "@id": "urn:ex/vav-536-more-heat-requests",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-214-temp-sensor",
+ "@type": [
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/room-214-hvac-domain"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:ex/zone-214-temp"
}
]
},
{
- "@id": "urn:ex/office-ahu-hot-water-in-connection",
+ "@id": "urn:ex/connection-to-room-103",
"@type": [
"http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-510-damper-command",
+ "@id": "urn:ex/vav-528-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-528-hot-water-in-connection"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-528-hot-water-in"
}
]
},
{
- "@id": "urn:ex/vav-536-air-out",
+ "@id": "urn:ex/vav-530",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-313"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:ex/vav-530-air-in"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "@id": "urn:ex/vav-530-air-out"
+ },
{
- "@id": "urn:ex/vav-536-discharge-air-flow"
+ "@id": "urn:ex/vav-530-hot-water-in"
},
{
- "@id": "urn:ex/vav-536-discharge-air-flow-setpoint"
+ "@id": "urn:ex/vav-530-hot-water-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#contains": [
+ {
+ "@id": "urn:ex/vav-530-damper"
},
{
- "@id": "urn:ex/vav-536-discharge-air-temp"
+ "@id": "urn:ex/vav-530-reheat-coil"
},
{
- "@id": "urn:ex/vav-536-discharge-air-temp-setpoint"
+ "@id": "urn:ex/vav-530-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/vav-522-damper-position",
+ "@id": "urn:ex/vav-528-damper-position",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -12919,188 +12808,191 @@
]
},
{
- "@id": "urn:ex/room-204",
+ "@id": "urn:ex/vav-526-damper-actuator",
+ "@type": [
+ "http://data.ashrae.org/standard223#Actuator"
+ ],
+ "http://data.ashrae.org/standard223#actuates": [
+ {
+ "@id": "urn:ex/vav-526-damper"
+ }
+ ],
+ "http://data.ashrae.org/standard223#commandedByProperty": [
+ {
+ "@id": "urn:ex/vav-526-damper-command"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/room-306",
"@type": [
"http://data.ashrae.org/standard223#PhysicalSpace"
],
"http://data.ashrae.org/standard223#encloses": [
{
- "@id": "urn:ex/room-204-hvac-domain"
+ "@id": "urn:ex/room-306-hvac-domain"
}
]
},
{
- "@id": "urn:ex/zone-207-cooling-setpoint",
+ "@id": "urn:ex/vav-528-cooling-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-502-damper",
+ "@id": "urn:ex/vav-539-discharge-air-flow",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-502-damper-in"
- },
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/vav-502-damper-out"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-502-damper-command"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-502-damper-position"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/office-ahu-htg-coil-valve-out",
+ "@id": "urn:ex/vav-538-damper-command",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/office-ahu-hot-water-out-connection"
- }
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/office-ahu-hot-water-out"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/zone-305-occupancy-sensor",
+ "@id": "urn:ex/vav-512-reheat-coil-valve-command",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-305-hvac-domain"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/zone-305-occupancy"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-527-reheat-coil-valve-out",
+ "@id": "urn:ex/room-313-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-527-hot-water-out-connection"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-527-hot-water-out"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-511-hot-water-in-connection",
+ "@id": "urn:ex/room-314-out",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
- ]
- },
- {
- "@id": "urn:ex/zone-201-occupancy",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-522-hot-water-in-connection",
+ "@id": "urn:ex/vav-537-reheat-coil-air-in",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-537-duct-after-damper"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-525-discharge-air-flow-setpoint",
+ "@id": "urn:ex/vav-525-more-heat-requests",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-537-reheat-coil-water-out",
+ "@id": "urn:ex/vav-528-damper",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-537-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-528-damper-in"
+ },
+ {
+ "@id": "urn:ex/vav-528-damper-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-528-damper-command"
+ },
+ {
+ "@id": "urn:ex/vav-528-damper-position"
}
]
},
{
- "@id": "urn:ex/vav-527-air-out",
+ "@id": "urn:ex/vav-502-damper-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-301"
+ "@id": "urn:ex/vav-502-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -13110,43 +13002,48 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-527-discharge-air-flow"
- },
- {
- "@id": "urn:ex/vav-527-discharge-air-flow-setpoint"
- },
- {
- "@id": "urn:ex/vav-527-discharge-air-temp"
+ "@id": "urn:ex/vav-502-colder-supply-air-requests"
},
{
- "@id": "urn:ex/vav-527-discharge-air-temp-setpoint"
+ "@id": "urn:ex/vav-502-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/office-ahu-ra-damper-command",
+ "@id": "urn:ex/vav-520-reheat-coil-air-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-520-duct-after-damper"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/room-205-in",
+ "@id": "urn:ex/vav-526-more-heat-requests",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ {
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/room-308-out",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-204-205"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -13156,13 +13053,13 @@
]
},
{
- "@id": "urn:ex/vav-501-reheat-coil-water-in",
+ "@id": "urn:ex/vav-520-reheat-coil-valve-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-501-hot-water-in-connection"
+ "@id": "urn:ex/vav-520-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -13172,77 +13069,95 @@
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-501-hot-water-in"
+ "@id": "urn:ex/vav-520-hot-water-out"
}
]
},
{
- "@id": "urn:ex/vav-515-discharge-air-temp-sensor",
+ "@id": "urn:ex/vav-517-pipe-hot-water-return-before-valve",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-515-air-out"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-507-pipe-hot-water-return-before-valve",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-515-discharge-air-temp"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/room-309-in",
+ "@id": "urn:ex/vav-522-air-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-309-310"
+ "@id": "urn:ex/connection-to-room-208-209"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-522-discharge-air-flow"
+ },
+ {
+ "@id": "urn:ex/vav-522-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-522-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-522-discharge-air-temp-setpoint"
+ }
]
},
{
- "@id": "urn:ex/room-111",
+ "@id": "urn:ex/vav-505-hot-water-in-connection",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/room-111-hvac-domain"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-519-reheat-coil-valve-actuator",
+ "@id": "urn:ex/zone-118-occupancy",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
- ],
- "http://data.ashrae.org/standard223#actuates": [
- {
- "@id": "urn:ex/vav-519-reheat-coil-valve"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-519-reheat-coil-valve-command"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
]
},
{
- "@id": "urn:ex/vav-532-hot-water-out",
+ "@id": "urn:ex/vav-539-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-532-hot-water-out-connection"
+ "@id": "urn:ex/vav-539-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -13252,23 +13167,23 @@
]
},
{
- "@id": "urn:ex/vav-529-discharge-air-temp-setpoint",
+ "@id": "urn:ex/vav-501-cooling-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/zone-208-209-heating-setpoint",
+ "@id": "urn:ex/vav-525-discharge-air-temp-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -13284,163 +13199,213 @@
]
},
{
- "@id": "urn:ex/zone-207-occupancy-override",
+ "@id": "urn:ex/vav-540-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "urn:ex/vav-540-pipe-hot-water-return-before-valve"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-523-air-in",
+ "@id": "urn:ex/vav-540-hot-water-in-connection",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/office-ahu-clg-coil-valve-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/office-ahu-pipe-chilled-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/zone-305-heating-setpoint",
+ "@id": "urn:ex/vav-505-reheat-coil-valve-command",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-518-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/vav-533-duct-after-damper",
"@type": [
"http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-515-discharge-air-flow",
+ "@id": "urn:ex/vav-527-hot-water-in-connection",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-521-heating-pid-output",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/room-302-out",
+ "@id": "urn:ex/vav-524-reheat-coil-valve-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/vav-524-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-524-hot-water-out"
}
]
},
{
- "@id": "urn:ex/zone-305-temp",
+ "@id": "urn:ex/room-213-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-536-discharge-air-flow-setpoint",
+ "@id": "urn:ex/vav-523-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:ex/vav-523-reheat-coil-valve"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:ex/vav-523-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/office-ahu-ra-fan-speed-cmd",
+ "@id": "urn:ex/vav-507",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-507-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-507-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-507-hot-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-507-hot-water-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/vav-507-damper"
+ },
+ {
+ "@id": "urn:ex/vav-507-reheat-coil"
+ },
+ {
+ "@id": "urn:ex/vav-507-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/zone-212-occupancy-sensor",
+ "@id": "urn:ex/vav-538-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-212-hvac-domain"
+ "@id": "urn:ex/vav-538-hot-water-in-connection"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-212-occupancy"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-538-hot-water-in"
}
]
},
{
- "@id": "urn:ex/vav-538-reheat-coil-valve-position",
+ "@id": "urn:ex/vav-526-damper-position",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -13456,278 +13421,262 @@
]
},
{
- "@id": "urn:ex/office-ahu-chilled-water-in-connection",
+ "@id": "urn:ex/zone-208-209-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-532-reheat-coil-water-in",
+ "@id": "urn:ex/vav-535-pipe-hot-water-return-before-valve",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-532-hot-water-in-connection"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-532-hot-water-in"
- }
]
},
{
- "@id": "urn:ex/vav-539-hot-water-in",
+ "@id": "urn:ex/room-209",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-539-hot-water-in-connection"
- }
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/room-209-hvac-domain"
}
]
},
{
- "@id": "urn:ex/vav-530-reheat-coil-water-out",
+ "@id": "urn:ex/vav-539-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/vav-530-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-539-reheat-coil-valve"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-539-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/vav-518-duct-after-damper",
+ "@id": "urn:ex/vav-511-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
- ]
- },
- {
- "@id": "urn:ex/zone-110-occupancy",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-523-reheat-coil-water-in",
+ "@id": "urn:ex/vav-529-discharge-air-flow",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/vav-523-hot-water-in-connection"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-523-hot-water-in"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-512-duct-after-damper",
+ "@id": "urn:ex/zone-106-107-occupancy-override",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
]
},
{
- "@id": "urn:ex/vav-524-discharge-air-flow",
+ "@id": "urn:ex/vav-538-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "@id": "urn:ex/vav-538-reheat-coil-air-in"
+ },
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:ex/vav-538-reheat-coil-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-538-reheat-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-538-reheat-coil-water-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/vav-503-damper-command",
+ "@id": "urn:ex/vav-528-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-528-reheat-coil-valve"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/vav-528-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/vav-515-damper-position",
+ "@id": "urn:ex/vav-515-heating-pid-output",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/zone-105",
+ "@id": "urn:ex/vav-521-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/room-105-hvac-domain"
+ "@id": "urn:ex/vav-521-damper"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "urn:ex/vav-521-damper-command"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-118-temp",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/zone-105-cooling-setpoint"
- },
- {
- "@id": "urn:ex/zone-105-heating-setpoint"
- },
- {
- "@id": "urn:ex/zone-105-occupancy"
- },
- {
- "@id": "urn:ex/zone-105-occupancy-override"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/zone-105-temp"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/zone-105-window-switch-on-off"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/zone-210-cooling-setpoint",
+ "@id": "urn:ex/zone-101-building-static-pressure-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/IN_H2O"
}
]
},
{
- "@id": "urn:ex/vav-537-reheat-coil-water-in",
+ "@id": "urn:ex/vav-528-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-537-hot-water-in-connection"
+ "@id": "urn:ex/vav-528-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-537-hot-water-in"
- }
]
},
{
- "@id": "urn:ex/vav-538-damper-in",
+ "@id": "urn:ex/vav-528-hot-water-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-528-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-531-duct-after-damper",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-538-air-in"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-536-damper-command",
+ "@id": "urn:ex/vav-504-reheat-coil-valve-position",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -13741,13 +13690,13 @@
]
},
{
- "@id": "urn:ex/vav-540-reheat-coil-air-in",
+ "@id": "urn:ex/vav-519-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-540-duct-after-damper"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -13757,124 +13706,132 @@
]
},
{
- "@id": "urn:ex/room-115-in",
+ "@id": "urn:ex/vav-536-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/connection-to-room-115"
- }
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-536-air-in"
}
- ]
- },
- {
- "@id": "urn:ex/vav-533-duct-after-damper",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-536-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/vav-520-reheat-coil-air-out",
+ "@id": "urn:ex/office-ahu-ra-fan",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Fan",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#FanWithVFD"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-207"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:ex/office-ahu-ra-fan-in"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/office-ahu-ra-fan-out"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-520-heating-pid-output"
+ "@id": "urn:ex/office-ahu-ra-fan-power"
},
{
- "@id": "urn:ex/vav-520-more-heat-requests"
+ "@id": "urn:ex/office-ahu-ra-fan-speed-cmd"
+ },
+ {
+ "@id": "urn:ex/office-ahu-ra-fan-speed-status"
+ },
+ {
+ "@id": "urn:ex/office-ahu-ra-fan-start-cmd"
+ },
+ {
+ "@id": "urn:ex/office-ahu-ra-fan-start-status"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "urn:ex/vav-520-air-out"
+ "@id": "http://data.ashrae.org/standard223#Role-Return"
}
]
},
{
- "@id": "urn:ex/room-117-in",
+ "@id": "urn:ex/vav-518-discharge-air-flow",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/connection-to-room-116-117"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/room-203-in",
+ "@id": "urn:ex/vav-521-reheat-coil-water-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-203"
+ "@id": "urn:ex/vav-521-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-521-hot-water-in"
}
]
},
{
- "@id": "urn:ex/vav-520-discharge-air-temp-sensor",
+ "@id": "urn:ex/vav-511-air-out",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-520-air-out"
+ "@id": "urn:ex/connection-to-room-112-114"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-520-discharge-air-temp"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/office-ahu-chilled-water-out-connection",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-511-discharge-air-flow"
+ },
+ {
+ "@id": "urn:ex/vav-511-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-511-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-511-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/vav-526-heating-pid-output",
+ "@id": "urn:ex/vav-510-heating-pid-output",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -13890,37 +13847,29 @@
]
},
{
- "@id": "urn:ex/vav-512-damper",
+ "@id": "urn:ex/room-306-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-512-damper-in"
+ "@id": "urn:ex/room-306-in"
},
{
- "@id": "urn:ex/vav-512-damper-out"
+ "@id": "urn:ex/room-306-out"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-512-damper-command"
- },
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:ex/vav-512-damper-position"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-506-hot-water-in",
+ "@id": "urn:ex/vav-508-hot-water-in-connection",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-506-hot-water-in-connection"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -13929,136 +13878,139 @@
]
},
{
- "@id": "urn:ex/vav-525",
+ "@id": "urn:ex/zone-104-temp",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-525-air-in"
- },
- {
- "@id": "urn:ex/vav-525-air-out"
- },
- {
- "@id": "urn:ex/vav-525-hot-water-in"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-525-hot-water-out"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-525-damper"
- },
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-535-discharge-air-flow-setpoint",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-525-reheat-coil"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-525-reheat-coil-valve"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/zone-106-107",
+ "@id": "urn:ex/room-109-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-106-hvac-domain"
+ "@id": "urn:ex/room-109-in"
},
{
- "@id": "urn:ex/room-107-hvac-domain"
+ "@id": "urn:ex/room-109-out"
}
],
"http://data.ashrae.org/standard223#hasDomain": [
{
"@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-505-reheat-coil-valve-in",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/zone-106-107-cooling-setpoint"
- },
- {
- "@id": "urn:ex/zone-106-107-heating-setpoint"
- },
- {
- "@id": "urn:ex/zone-106-107-occupancy"
- },
- {
- "@id": "urn:ex/zone-106-107-occupancy-override"
- },
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/zone-106-107-temp"
- },
+ "@id": "urn:ex/vav-505-pipe-hot-water-return-before-valve"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-106-107-window-switch-on-off"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/room-202-out",
+ "@id": "urn:ex/vav-525-damper-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/vav-525-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-525-colder-supply-air-requests"
+ },
+ {
+ "@id": "urn:ex/vav-525-cooling-pid-output"
+ }
]
},
{
- "@id": "urn:ex/vav-537-reheat-coil-valve-position",
+ "@id": "urn:ex/zone-305-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/room-305-hvac-domain"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/zone-305-temp"
}
]
},
{
- "@id": "urn:ex/vav-516-reheat-coil-air-in",
+ "@id": "urn:ex/zone-101-temp",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-516-duct-after-damper"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/room-211-hvac-domain",
+ "@id": "urn:ex/room-117-hvac-domain",
"@type": [
"http://data.ashrae.org/standard223#DomainSpace"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-211-in"
+ "@id": "urn:ex/room-117-in"
},
{
- "@id": "urn:ex/room-211-out"
+ "@id": "urn:ex/room-117-out"
}
],
"http://data.ashrae.org/standard223#hasDomain": [
@@ -14068,336 +14020,370 @@
]
},
{
- "@id": "urn:ex/vav-537-air-in",
+ "@id": "urn:ex/vav-531-reheat-coil-water-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-531-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-531-hot-water-in"
}
]
},
{
- "@id": "urn:ex/vav-536-damper-in",
+ "@id": "urn:ex/vav-503-hot-water-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-503-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-536-air-in"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-535-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-504-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-535-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/zone-214-heating-setpoint",
+ "@id": "urn:ex/vav-504-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-512-reheat-coil-air-in",
+ "@id": "urn:ex/vav-540-cooling-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-512-duct-after-damper"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-512-hot-water-out",
+ "@id": "urn:ex/vav-523-duct-after-damper",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-512-hot-water-out-connection"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-519-reheat-coil-valve-out",
+ "@id": "urn:ex/office-ahu-ra-fan-power",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-519-hot-water-out-connection"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-519-hot-water-out"
+ "@id": "http://qudt.org/vocab/unit/W"
}
]
},
{
- "@id": "urn:ex/room-113-hvac-domain",
+ "@id": "urn:ex/vav-508-heating-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/room-113-in"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-113-out"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-521-discharge-air-flow",
+ "@id": "urn:ex/vav-520-hot-water-out-connection",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-215-temp",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/zone-203-occupancy-sensor",
+ "@id": "urn:ex/connection-to-room-309-310",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/room-203-hvac-domain"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-312-window-switch-on-off",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/zone-203-occupancy"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/vav-506-colder-supply-air-requests",
+ "@id": "urn:ex/room-214",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/room-214-hvac-domain"
}
]
},
{
- "@id": "urn:ex/vav-527-damper",
+ "@id": "urn:ex/vav-516-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-527-damper-in"
+ "@id": "urn:ex/vav-516-reheat-coil-valve-in"
},
{
- "@id": "urn:ex/vav-527-damper-out"
+ "@id": "urn:ex/vav-516-reheat-coil-valve-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-527-damper-command"
+ "@id": "urn:ex/vav-516-reheat-coil-valve-command"
},
{
- "@id": "urn:ex/vav-527-damper-position"
+ "@id": "urn:ex/vav-516-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/room-214-hvac-domain",
+ "@id": "urn:ex/room-105-out",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-214-in"
- },
- {
- "@id": "urn:ex/room-214-out"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/zone-118-window-switch-on-off",
+ "@id": "urn:ex/vav-522-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "urn:ex/vav-522-reheat-coil-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-522-reheat-coil-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-522-reheat-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-522-reheat-coil-water-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasRole": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/vav-509-more-heat-requests",
+ "@id": "urn:ex/vav-525-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/vav-525-pipe-hot-water-return-before-valve"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/zone-110-occupancy-sensor",
+ "@id": "urn:ex/vav-503-heating-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-110-hvac-domain"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/zone-110-occupancy"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/zone-301-heating-setpoint",
+ "@id": "urn:ex/vav-530-cooling-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-524-colder-supply-air-requests",
+ "@id": "urn:ex/vav-537-hot-water-in",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/vav-537-hot-water-in-connection"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-534-reheat-coil-valve-actuator",
+ "@id": "urn:ex/room-110-out",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-534-reheat-coil-valve"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-534-reheat-coil-valve-command"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/office-ahu-increased-air-pressure-requests",
+ "@id": "urn:ex/vav-514-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-508-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-532-reheat-coil-valve-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-508-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-532-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -14407,156 +14393,169 @@
]
},
{
- "@id": "urn:ex/zone-111-window-switch-on-off",
+ "@id": "urn:ex/room-203-out",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-538-damper-command",
+ "@id": "urn:ex/vav-532-air-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-531-air-in",
+ "@id": "urn:ex/zone-208-209-occupancy-sensor",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/room-208-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/zone-208-209-occupancy"
}
]
},
{
- "@id": "urn:ex/vav-513-damper-out",
+ "@id": "urn:ex/vav-523-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-513-duct-after-damper"
+ "@id": "urn:ex/vav-523-reheat-coil-valve-in"
+ },
+ {
+ "@id": "urn:ex/vav-523-reheat-coil-valve-out"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-513-colder-supply-air-requests"
+ "@id": "urn:ex/vav-523-reheat-coil-valve-command"
},
{
- "@id": "urn:ex/vav-513-cooling-pid-output"
+ "@id": "urn:ex/vav-523-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-530-damper",
+ "@id": "urn:ex/zone-302-co2-concentration",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-530-damper-in"
- },
+ "http://data.ashrae.org/standard223#ofSubstance": [
{
- "@id": "urn:ex/vav-530-damper-out"
+ "@id": "http://data.ashrae.org/standard223#Substance-CO2"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-530-damper-command"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/MoleFraction"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-530-damper-position"
+ "@id": "http://qudt.org/vocab/unit/PPM"
}
]
},
{
- "@id": "urn:ex/vav-530-reheat-coil-valve-actuator",
+ "@id": "urn:ex/vav-535-reheat-coil-valve-actuator",
"@type": [
"http://data.ashrae.org/standard223#Actuator"
],
"http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/vav-530-reheat-coil-valve"
+ "@id": "urn:ex/vav-535-reheat-coil-valve"
}
],
"http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/vav-530-reheat-coil-valve-command"
+ "@id": "urn:ex/vav-535-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/zone-208-209-occupancy-override",
+ "@id": "urn:ex/vav-537-hot-water-out-connection",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-511-hot-water-out",
+ "@id": "urn:ex/zone-102",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/vav-511-hot-water-out-connection"
+ "@id": "urn:ex/room-102-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
- ]
- },
- {
- "@id": "urn:ex/vav-537-discharge-air-flow-sensor",
- "@type": [
- "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-537-air-in"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
+ "@id": "urn:ex/zone-102-cooling-setpoint"
+ },
{
- "@id": "urn:ex/vav-537-discharge-air-flow"
+ "@id": "urn:ex/zone-102-heating-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-102-occupancy"
+ },
+ {
+ "@id": "urn:ex/zone-102-occupancy-override"
+ },
+ {
+ "@id": "urn:ex/zone-102-temp"
+ },
+ {
+ "@id": "urn:ex/zone-102-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-518-discharge-air-temp",
+ "@id": "urn:ex/vav-503-discharge-air-flow",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -14567,119 +14566,145 @@
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-519-heating-pid-output",
+ "@id": "urn:ex/vav-516-discharge-air-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/connection-to-room-207",
+ "@id": "urn:ex/vav-506-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-506-air-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:ex/vav-506-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/office-ahu-moisture-eliminator-out",
+ "@id": "urn:ex/zone-101-temp-sensor",
+ "@type": [
+ "http://data.ashrae.org/standard223#Sensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "urn:ex/room-101-hvac-domain"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:ex/zone-101-temp"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/office-ahu-chilled-water-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-duct-after-moisture-eliminator"
+ "@id": "urn:ex/office-ahu-chilled-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-536-discharge-air-flow",
+ "@id": "urn:ex/vav-512-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:ex/vav-512-air-in"
}
]
},
{
- "@id": "urn:ex/vav-501-discharge-air-flow",
+ "@id": "urn:ex/office-ahu-oa-damper-command",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/zone-314-temp-sensor",
+ "@id": "urn:ex/vav-511-hot-water-in",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-314-hvac-domain"
+ "@id": "urn:ex/vav-511-hot-water-in-connection"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-314-temp"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-527-duct-after-damper",
+ "@id": "urn:ex/zone-102-occupancy-override",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ {
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/office-ahu-duct-after-air-filter",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Duct"
@@ -14691,169 +14716,163 @@
]
},
{
- "@id": "urn:ex/zone-102",
+ "@id": "urn:ex/vav-507-cooling-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-102-hvac-domain"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-507-colder-supply-air-requests",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ {
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-535",
+ "@type": [
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/zone-102-cooling-setpoint"
+ "@id": "urn:ex/vav-535-air-in"
},
{
- "@id": "urn:ex/zone-102-heating-setpoint"
+ "@id": "urn:ex/vav-535-air-out"
},
{
- "@id": "urn:ex/zone-102-occupancy"
+ "@id": "urn:ex/vav-535-hot-water-in"
},
{
- "@id": "urn:ex/zone-102-occupancy-override"
+ "@id": "urn:ex/vav-535-hot-water-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#contains": [
+ {
+ "@id": "urn:ex/vav-535-damper"
},
{
- "@id": "urn:ex/zone-102-temp"
+ "@id": "urn:ex/vav-535-reheat-coil"
},
{
- "@id": "urn:ex/zone-102-window-switch-on-off"
+ "@id": "urn:ex/vav-535-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/vav-507-reheat-coil-valve-out",
+ "@id": "urn:ex/vav-539-discharge-air-temp",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/vav-507-hot-water-out-connection"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-507-hot-water-out"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-529-damper-position",
+ "@id": "urn:ex/vav-538-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-538-damper"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/vav-538-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-515-air-out",
+ "@id": "urn:ex/vav-537-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-116-117"
+ "@id": "urn:ex/vav-537-reheat-coil-valve-in"
+ },
+ {
+ "@id": "urn:ex/vav-537-reheat-coil-valve-out"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-515-discharge-air-flow"
- },
- {
- "@id": "urn:ex/vav-515-discharge-air-flow-setpoint"
- },
- {
- "@id": "urn:ex/vav-515-discharge-air-temp"
+ "@id": "urn:ex/vav-537-reheat-coil-valve-command"
},
{
- "@id": "urn:ex/vav-515-discharge-air-temp-setpoint"
+ "@id": "urn:ex/vav-537-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/office-ahu-ra-fan",
+ "@id": "urn:ex/vav-533-reheat-coil-air-in",
"@type": [
- "http://data.ashrae.org/standard223#Fan",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#FanWithVFD"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-ra-fan-in"
- },
- {
- "@id": "urn:ex/office-ahu-ra-fan-out"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/office-ahu-ra-fan-power"
- },
- {
- "@id": "urn:ex/office-ahu-ra-fan-speed-cmd"
- },
- {
- "@id": "urn:ex/office-ahu-ra-fan-speed-status"
- },
- {
- "@id": "urn:ex/office-ahu-ra-fan-start-cmd"
- },
- {
- "@id": "urn:ex/office-ahu-ra-fan-start-status"
+ "@id": "urn:ex/vav-533-duct-after-damper"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Return"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-528-damper-in",
+ "@id": "urn:ex/vav-530-reheat-coil-valve-position",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/office-ahu-connection-to-vavs"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-528-air-in"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-519-discharge-air-temp",
+ "@id": "urn:ex/vav-511-discharge-air-temp",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -14874,179 +14893,185 @@
]
},
{
- "@id": "urn:ex/room-310-hvac-domain",
+ "@id": "urn:ex/vav-533-air-out",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-310-in"
- },
- {
- "@id": "urn:ex/room-310-out"
+ "@id": "urn:ex/connection-to-room-305"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/vav-502-heating-pid-output",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "urn:ex/vav-533-discharge-air-flow"
+ },
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "urn:ex/vav-533-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-533-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-533-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/zone-312-temp",
+ "@id": "urn:ex/vav-540-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-540-air-in"
}
]
},
{
- "@id": "urn:ex/zone-213-window-switch-on-off",
+ "@id": "urn:ex/vav-529-hot-water-out-connection",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-519-discharge-air-flow",
+ "@id": "urn:ex/vav-523-reheat-coil-valve-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ "@id": "urn:ex/vav-523-hot-water-out-connection"
}
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:ex/vav-523-hot-water-out"
}
]
},
{
- "@id": "urn:ex/vav-520-damper",
+ "@id": "urn:ex/vav-539-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-520-damper-in"
+ "@id": "urn:ex/vav-539-reheat-coil-valve-in"
},
{
- "@id": "urn:ex/vav-520-damper-out"
+ "@id": "urn:ex/vav-539-reheat-coil-valve-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-520-damper-command"
+ "@id": "urn:ex/vav-539-reheat-coil-valve-command"
},
{
- "@id": "urn:ex/vav-520-damper-position"
+ "@id": "urn:ex/vav-539-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/connection-to-room-108",
+ "@id": "urn:ex/zone-305-occupancy-override",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
]
},
{
- "@id": "urn:ex/vav-520-cooling-pid-output",
+ "@id": "urn:ex/zone-211-cooling-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-538-reheat-coil-valve-command",
+ "@id": "urn:ex/vav-527-reheat-coil-valve-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-527-hot-water-out-connection"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-527-hot-water-out"
}
]
},
{
- "@id": "urn:ex/zone-202-temp",
+ "@id": "urn:ex/vav-505-duct-after-damper",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-513-reheat-coil-air-out",
+ "@id": "urn:ex/vav-507-damper-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-103"
+ "@id": "urn:ex/vav-507-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -15056,109 +15081,101 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-513-heating-pid-output"
+ "@id": "urn:ex/vav-507-colder-supply-air-requests"
},
{
- "@id": "urn:ex/vav-513-more-heat-requests"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-513-air-out"
+ "@id": "urn:ex/vav-507-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/zone-303-304-306-window-switch-on-off",
+ "@id": "urn:ex/room-311",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "urn:ex/room-311-hvac-domain"
}
]
},
{
- "@id": "urn:ex/vav-538-reheat-coil-valve-actuator",
+ "@id": "urn:ex/vav-516-air-out",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-538-reheat-coil-valve"
+ "@id": "urn:ex/connection-to-room-201"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-538-reheat-coil-valve-command"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-516-discharge-air-flow"
+ },
+ {
+ "@id": "urn:ex/vav-516-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-516-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-516-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/zone-201-temp-sensor",
+ "@id": "urn:ex/vav-516-discharge-air-flow-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/room-201-hvac-domain"
+ "@id": "urn:ex/vav-516-air-in"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/zone-201-temp"
+ "@id": "urn:ex/vav-516-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/vav-511-reheat-coil-valve",
+ "@id": "urn:ex/vav-522-damper",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-511-reheat-coil-valve-in"
+ "@id": "urn:ex/vav-522-damper-in"
},
{
- "@id": "urn:ex/vav-511-reheat-coil-valve-out"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "urn:ex/vav-522-damper-out"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-511-reheat-coil-valve-command"
+ "@id": "urn:ex/vav-522-damper-command"
},
{
- "@id": "urn:ex/vav-511-reheat-coil-valve-position"
- }
- ]
- },
- {
- "@id": "urn:ex/connection-to-room-210",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-522-damper-position"
}
]
},
{
- "@id": "urn:ex/vav-514-discharge-air-flow",
+ "@id": "urn:ex/office-ahu-oa-flow",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ "@id": "http://data.ashrae.org/standard223#Role-Outside"
}
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
@@ -15173,9 +15190,9 @@
]
},
{
- "@id": "urn:ex/vav-506-damper-position",
+ "@id": "urn:ex/vav-504-reheat-coil-valve-command",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -15189,121 +15206,111 @@
]
},
{
- "@id": "urn:ex/vav-527-cooling-pid-output",
+ "@id": "urn:ex/vav-505-discharge-air-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-526-reheat-coil-valve-actuator",
+ "@id": "urn:ex/vav-522-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
- ],
- "http://data.ashrae.org/standard223#actuates": [
- {
- "@id": "urn:ex/vav-526-reheat-coil-valve"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-526-reheat-coil-valve-command"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
- ]
- },
- {
- "@id": "urn:ex/zone-208-209-temp-sensor",
- "@type": [
- "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/room-208-hvac-domain"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/zone-208-209-temp"
+ "@id": "urn:ex/vav-522-air-in"
}
]
},
{
- "@id": "urn:ex/vav-509-reheat-coil-valve-out",
+ "@id": "urn:ex/room-214-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-509-hot-water-out-connection"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:ex/room-214-in"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/room-214-out"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:ex/vav-509-hot-water-out"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/zone-213-heating-setpoint",
+ "@id": "urn:ex/vav-517-air-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-535-damper",
+ "@id": "urn:ex/vav-515-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-535-damper-in"
+ "@id": "urn:ex/vav-515-reheat-coil-air-in"
},
{
- "@id": "urn:ex/vav-535-damper-out"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "@id": "urn:ex/vav-515-reheat-coil-air-out"
+ },
{
- "@id": "urn:ex/vav-535-damper-command"
+ "@id": "urn:ex/vav-515-reheat-coil-water-in"
},
{
- "@id": "urn:ex/vav-535-damper-position"
+ "@id": "urn:ex/vav-515-reheat-coil-water-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasRole": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/office-ahu-htg-coil-air-in",
+ "@id": "urn:ex/vav-518-reheat-coil-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-duct-after-air-filter"
+ "@id": "urn:ex/vav-518-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -15313,7 +15320,19 @@
]
},
{
- "@id": "urn:ex/vav-518-damper-position",
+ "@id": "urn:ex/vav-513-duct-after-damper",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-512-damper-position",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -15329,275 +15348,195 @@
]
},
{
- "@id": "urn:ex/vav-518-reheat-coil-valve-actuator",
+ "@id": "urn:ex/vav-523-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-518-reheat-coil-valve"
+ "@id": "urn:ex/vav-523-air-out"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-518-reheat-coil-valve-command"
+ "@id": "urn:ex/vav-523-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/vav-501-cooling-pid-output",
+ "@id": "urn:ex/zone-207-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/room-207-hvac-domain"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "urn:ex/zone-207-temp"
}
]
},
{
- "@id": "urn:ex/vav-526-damper-actuator",
+ "@id": "urn:ex/zone-106-107-window-switch-on-off",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
- ],
- "http://data.ashrae.org/standard223#actuates": [
- {
- "@id": "urn:ex/vav-526-damper"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-526-damper-command"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/vav-508-damper-out",
+ "@id": "urn:ex/zone-311-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-508-duct-after-damper"
- }
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/room-311-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-508-colder-supply-air-requests"
- },
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-508-cooling-pid-output"
+ "@id": "urn:ex/zone-311-temp"
}
]
},
{
- "@id": "urn:ex/office-ahu-sa-flow",
+ "@id": "urn:ex/vav-518-damper",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Supply"
- }
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "@id": "urn:ex/vav-518-damper-in"
+ },
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:ex/vav-518-damper-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:ex/vav-518-damper-command"
+ },
+ {
+ "@id": "urn:ex/vav-518-damper-position"
}
]
},
{
- "@id": "urn:ex/vav-535-damper-in",
+ "@id": "urn:ex/vav-530-reheat-coil-water-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-530-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-535-air-in"
+ "@id": "urn:ex/vav-530-hot-water-in"
}
]
},
{
- "@id": "urn:ex/vav-529-air-out",
+ "@id": "urn:ex/vav-523-discharge-air-temp",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/connection-to-room-303-304-306"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-529-discharge-air-flow"
- },
- {
- "@id": "urn:ex/vav-529-discharge-air-flow-setpoint"
- },
- {
- "@id": "urn:ex/vav-529-discharge-air-temp"
- },
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/vav-529-discharge-air-temp-setpoint"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
- ]
- },
- {
- "@id": "urn:ex/vav-504-damper-actuator",
- "@type": [
- "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-504-damper"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-504-damper-command"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-521-reheat-coil-water-in",
+ "@id": "urn:ex/vav-514-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-521-hot-water-in-connection"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-521-hot-water-in"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-537-air-out",
+ "@id": "urn:ex/zone-208-209-cooling-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/connection-to-room-312"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-537-discharge-air-flow"
- },
- {
- "@id": "urn:ex/vav-537-discharge-air-flow-setpoint"
- },
- {
- "@id": "urn:ex/vav-537-discharge-air-temp"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-537-discharge-air-temp-setpoint"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
- ]
- },
- {
- "@id": "urn:ex/vav-522-pipe-hot-water-return-before-valve",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-536-discharge-air-temp",
+ "@id": "urn:ex/vav-515-reheat-coil-valve-position",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
- ],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-501-damper-out",
+ "@id": "urn:ex/vav-503-air-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-501-duct-after-damper"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-501-colder-supply-air-requests"
- },
- {
- "@id": "urn:ex/vav-501-cooling-pid-output"
- }
]
},
{
- "@id": "urn:ex/vav-514-discharge-air-temp-setpoint",
+ "@id": "urn:ex/zone-101-cooling-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -15613,156 +15552,177 @@
]
},
{
- "@id": "urn:ex/vav-522-discharge-air-temp-sensor",
+ "@id": "urn:ex/vav-536-discharge-air-temp",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/vav-522-air-out"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-522-discharge-air-temp"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-517-damper",
+ "@id": "urn:ex/vav-514-hot-water-in",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-517-damper-in"
- },
- {
- "@id": "urn:ex/vav-517-damper-out"
+ "@id": "urn:ex/vav-514-hot-water-in-connection"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-517-damper-command"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-517-damper-position"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-514-reheat-coil-valve-command",
+ "@id": "urn:ex/vav-511-pipe-hot-water-return-before-valve",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-502-reheat-coil-valve-out",
+ "@id": "urn:ex/vav-514-hot-water-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-502-hot-water-out-connection"
+ "@id": "urn:ex/vav-514-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-112-114-window-switch-on-off",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-502-hot-water-out"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/office-ahu-oa-in",
+ "@id": "urn:ex/zone-203-cooling-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/office-ahu-oa-in-connection"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-534-damper",
+ "@id": "urn:ex/vav-512-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-534-damper-in"
+ "@id": "urn:ex/vav-512-reheat-coil-air-in"
},
{
- "@id": "urn:ex/vav-534-damper-out"
+ "@id": "urn:ex/vav-512-reheat-coil-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-512-reheat-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-512-reheat-coil-water-out"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "urn:ex/vav-534-damper-command"
- },
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-203-occupancy-override",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-534-damper-position"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
]
},
{
- "@id": "urn:ex/vav-512-discharge-air-temp",
+ "@id": "urn:ex/vav-516-pipe-hot-water-return-before-valve",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-532-reheat-coil-air-in",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-532-duct-after-damper"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-505-colder-supply-air-requests",
+ "@id": "urn:ex/zone-301-occupancy-override",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
]
},
{
- "@id": "urn:ex/vav-529-reheat-coil-valve-position",
+ "@id": "urn:ex/vav-528-damper-command",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -15776,60 +15736,34 @@
]
},
{
- "@id": "urn:ex/vav-507-discharge-air-temp-sensor",
+ "@id": "urn:ex/zone-105-occupancy-override",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:ex/vav-507-air-out"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-507-discharge-air-temp"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
]
},
{
- "@id": "urn:ex/vav-501-hot-water-in",
+ "@id": "urn:ex/vav-540-reheat-coil-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-501-hot-water-in-connection"
+ "@id": "urn:ex/vav-540-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ]
- },
- {
- "@id": "urn:ex/office-ahu-ra-temp",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Return"
- }
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
- {
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/room-305-out",
+ "@id": "urn:ex/room-204-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -15845,13 +15779,13 @@
]
},
{
- "@id": "urn:ex/vav-531-hot-water-out",
+ "@id": "urn:ex/vav-527-hot-water-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-531-hot-water-out-connection"
+ "@id": "urn:ex/vav-527-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -15861,58 +15795,67 @@
]
},
{
- "@id": "urn:ex/vav-508-damper-position",
+ "@id": "urn:ex/vav-518-hot-water-in-connection",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-520-damper-out",
+ "@id": "urn:ex/vav-512",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-520-duct-after-damper"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:ex/vav-512-air-in"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-512-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-512-hot-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-512-hot-water-out"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/vav-520-colder-supply-air-requests"
+ "@id": "urn:ex/vav-512-damper"
},
{
- "@id": "urn:ex/vav-520-cooling-pid-output"
+ "@id": "urn:ex/vav-512-reheat-coil"
+ },
+ {
+ "@id": "urn:ex/vav-512-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/zone-302-window-switch-on-off",
+ "@id": "urn:ex/vav-525-hot-water-in",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "urn:ex/vav-525-hot-water-in-connection"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-531-cooling-pid-output",
+ "@id": "urn:ex/vav-526-cooling-pid-output",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -15928,200 +15871,196 @@
]
},
{
- "@id": "urn:ex/zone-103-temp-sensor",
+ "@id": "urn:ex/zone-118-cooling-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-103-hvac-domain"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/zone-103-temp"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-537-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/zone-108-occupancy-sensor",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/room-108-hvac-domain"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:ex/zone-108-occupancy"
}
]
},
{
- "@id": "urn:ex/vav-538-damper-actuator",
+ "@id": "urn:ex/vav-519-damper-actuator",
"@type": [
"http://data.ashrae.org/standard223#Actuator"
],
"http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/vav-538-damper"
+ "@id": "urn:ex/vav-519-damper"
}
],
"http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/vav-538-damper-command"
+ "@id": "urn:ex/vav-519-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-534-reheat-coil-valve-out",
+ "@id": "urn:ex/vav-515-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-534-hot-water-out-connection"
+ "@id": "urn:ex/vav-515-reheat-coil-valve-in"
+ },
+ {
+ "@id": "urn:ex/vav-515-reheat-coil-valve-out"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-534-hot-water-out"
+ "@id": "urn:ex/vav-515-reheat-coil-valve-command"
+ },
+ {
+ "@id": "urn:ex/vav-515-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-528-discharge-air-temp-setpoint",
+ "@id": "urn:ex/vav-539-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-539-air-in"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-539-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/vav-501-damper",
+ "@id": "urn:ex/vav-533-damper",
"@type": [
"http://data.ashrae.org/standard223#Damper",
"http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-501-damper-in"
+ "@id": "urn:ex/vav-533-damper-in"
},
{
- "@id": "urn:ex/vav-501-damper-out"
+ "@id": "urn:ex/vav-533-damper-out"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-501-damper-command"
+ "@id": "urn:ex/vav-533-damper-command"
},
{
- "@id": "urn:ex/vav-501-damper-position"
+ "@id": "urn:ex/vav-533-damper-position"
}
]
},
{
- "@id": "urn:ex/zone-206-occupancy-sensor",
+ "@id": "urn:ex/vav-512-air-out",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-206-hvac-domain"
+ "@id": "urn:ex/connection-to-room-118"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-206-occupancy"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/vav-531-reheat-coil",
- "@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-531-reheat-coil-air-in"
+ "@id": "urn:ex/vav-512-discharge-air-flow"
},
{
- "@id": "urn:ex/vav-531-reheat-coil-air-out"
+ "@id": "urn:ex/vav-512-discharge-air-flow-setpoint"
},
{
- "@id": "urn:ex/vav-531-reheat-coil-water-in"
+ "@id": "urn:ex/vav-512-discharge-air-temp"
},
{
- "@id": "urn:ex/vav-531-reheat-coil-water-out"
- }
- ],
- "http://data.ashrae.org/standard223#hasRole": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "urn:ex/vav-512-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/zone-210-heating-setpoint",
+ "@id": "urn:ex/vav-515-reheat-coil-valve-command",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-531-reheat-coil-valve",
+ "@id": "urn:ex/vav-502-reheat-coil-valve-out",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-531-reheat-coil-valve-in"
- },
- {
- "@id": "urn:ex/vav-531-reheat-coil-valve-out"
+ "@id": "urn:ex/vav-502-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-531-reheat-coil-valve-command"
- },
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-531-reheat-coil-valve-position"
+ "@id": "urn:ex/vav-502-hot-water-out"
}
]
},
{
- "@id": "urn:ex/connection-to-room-112-114",
+ "@id": "urn:ex/office-ahu-air-filter-out",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/office-ahu-duct-after-air-filter"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -16130,132 +16069,195 @@
]
},
{
- "@id": "urn:ex/room-213-hvac-domain",
+ "@id": "urn:ex/office-ahu-htg-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-213-in"
- },
- {
- "@id": "urn:ex/room-213-out"
+ "@id": "urn:ex/office-ahu-pipe-hot-water-return-before-valve"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/office-ahu-clg-coil-valve-command",
+ "@id": "urn:ex/vav-532-discharge-air-temp-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/zone-208-209",
+ "@id": "urn:ex/vav-510-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-208-hvac-domain"
- },
+ "@id": "urn:ex/vav-510-hot-water-in-connection"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/room-209-hvac-domain"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "urn:ex/vav-510-hot-water-in"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-516-more-heat-requests",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/zone-208-209-cooling-setpoint"
- },
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-535-reheat-coil-valve-in",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/zone-208-209-heating-setpoint"
- },
+ "@id": "urn:ex/vav-535-pipe-hot-water-return-before-valve"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-208-209-occupancy"
- },
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/room-110",
+ "@type": [
+ "http://data.ashrae.org/standard223#PhysicalSpace"
+ ],
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "urn:ex/zone-208-209-occupancy-override"
- },
+ "@id": "urn:ex/room-110-hvac-domain"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-106-107-heating-setpoint",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/zone-208-209-temp"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/zone-208-209-window-switch-on-off"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-524-reheat-coil-air-out",
+ "@id": "urn:ex/vav-528-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/connection-to-room-210"
+ "@id": "urn:ex/vav-528-air-in"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-528-discharge-air-flow"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-535-reheat-coil-water-in",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-524-heating-pid-output"
- },
+ "@id": "urn:ex/vav-535-hot-water-in-connection"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-524-more-heat-requests"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-524-air-out"
+ "@id": "urn:ex/vav-535-hot-water-in"
}
]
},
{
- "@id": "urn:ex/vav-509-discharge-air-flow",
+ "@id": "urn:ex/vav-521-duct-after-damper",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-526-damper-command",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/zone-202-occupancy-sensor",
+ "@id": "urn:ex/vav-540-discharge-air-temp-sensor",
+ "@type": [
+ "http://data.ashrae.org/standard223#Sensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "urn:ex/vav-540-air-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:ex/vav-540-discharge-air-temp"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-202-temp-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
@@ -16266,50 +16268,57 @@
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/zone-202-occupancy"
+ "@id": "urn:ex/zone-202-temp"
}
]
},
{
- "@id": "urn:ex/vav-503-reheat-coil-valve-actuator",
+ "@id": "urn:ex/vav-526-hot-water-in",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-503-reheat-coil-valve"
+ "@id": "urn:ex/vav-526-hot-water-in-connection"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-503-reheat-coil-valve-command"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-501-reheat-coil-valve-actuator",
+ "@id": "urn:ex/vav-507-hot-water-out-connection",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-501-reheat-coil-valve"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-534-colder-supply-air-requests",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-501-reheat-coil-valve-command"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-506-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-535-hot-water-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-506-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-535-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -16319,7 +16328,18 @@
]
},
{
- "@id": "urn:ex/vav-512-damper-in",
+ "@id": "urn:ex/zone-202-occupancy-override",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ {
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-515-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -16332,147 +16352,164 @@
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-512-air-in"
- }
]
},
{
- "@id": "urn:ex/vav-502-reheat-coil",
+ "@id": "urn:ex/room-301-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-502-reheat-coil-air-in"
- },
- {
- "@id": "urn:ex/vav-502-reheat-coil-air-out"
- },
- {
- "@id": "urn:ex/vav-502-reheat-coil-water-in"
+ "@id": "urn:ex/room-301-in"
},
{
- "@id": "urn:ex/vav-502-reheat-coil-water-out"
+ "@id": "urn:ex/room-301-out"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/room-215-hvac-domain",
+ "@id": "urn:ex/vav-522-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/room-215-in"
- },
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/room-215-out"
+ "@id": "urn:ex/vav-522-damper"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "urn:ex/vav-522-damper-command"
}
]
},
{
- "@id": "urn:ex/room-303-out",
+ "@id": "urn:ex/vav-524-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/connection-to-room-210"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-524-discharge-air-flow"
+ },
+ {
+ "@id": "urn:ex/vav-524-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-524-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-524-discharge-air-temp-setpoint"
+ }
]
},
{
- "@id": "urn:ex/vav-536-cooling-pid-output",
+ "@id": "urn:ex/vav-509-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/vav-509-reheat-coil-valve-in"
+ },
+ {
+ "@id": "urn:ex/vav-509-reheat-coil-valve-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-509-reheat-coil-valve-command"
+ },
+ {
+ "@id": "urn:ex/vav-509-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-522-cooling-pid-output",
+ "@id": "urn:ex/vav-506-reheat-coil-valve-position",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-506-discharge-air-flow",
+ "@id": "urn:ex/vav-506-discharge-air-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/room-207-out",
+ "@id": "urn:ex/vav-512-hot-water-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/vav-512-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-517-reheat-coil-valve-position",
+ "@id": "urn:ex/room-201",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
+ ],
+ "http://data.ashrae.org/standard223#encloses": [
+ {
+ "@id": "urn:ex/room-201-hvac-domain"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-508-damper-command",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -16486,30 +16523,30 @@
]
},
{
- "@id": "urn:ex/vav-503-reheat-coil-water-in",
+ "@id": "urn:ex/vav-523-damper-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-503-hot-water-in-connection"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-503-hot-water-in"
+ "@id": "urn:ex/vav-523-air-in"
}
]
},
{
- "@id": "urn:ex/zone-314-temp",
+ "@id": "urn:ex/zone-202-cooling-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -16523,107 +16560,58 @@
]
},
{
- "@id": "urn:ex/vav-503",
- "@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-503-air-in"
- },
- {
- "@id": "urn:ex/vav-503-air-out"
- },
- {
- "@id": "urn:ex/vav-503-hot-water-in"
- },
- {
- "@id": "urn:ex/vav-503-hot-water-out"
- }
- ],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/vav-503-damper"
- },
- {
- "@id": "urn:ex/vav-503-reheat-coil"
- },
- {
- "@id": "urn:ex/vav-503-reheat-coil-valve"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-510-discharge-air-flow",
+ "@id": "urn:ex/zone-105-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:ex/room-105-hvac-domain"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:ex/zone-105-temp"
}
]
},
{
- "@id": "urn:ex/room-308-hvac-domain",
+ "@id": "urn:ex/room-109-out",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-308-in"
- },
- {
- "@id": "urn:ex/room-308-out"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-529-damper-in",
+ "@id": "urn:ex/room-305-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/connection-to-room-305"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-529-air-in"
- }
]
},
{
- "@id": "urn:ex/vav-537-hot-water-out",
+ "@id": "urn:ex/vav-513-pipe-hot-water-return-before-valve",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-537-hot-water-out-connection"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -16632,13 +16620,13 @@
]
},
{
- "@id": "urn:ex/room-210-out",
+ "@id": "urn:ex/room-111-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/connection-to-room-111"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -16648,174 +16636,118 @@
]
},
{
- "@id": "urn:ex/zone-303-304-306-temp-sensor",
+ "@id": "urn:ex/vav-529-heating-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-303-hvac-domain"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/zone-303-304-306-temp"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/room-305-hvac-domain",
+ "@id": "urn:ex/zone-201-temp",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/room-305-in"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-305-out"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-521-hot-water-in",
+ "@id": "urn:ex/vav-508-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-521-hot-water-in-connection"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-539-reheat-coil",
+ "@id": "urn:ex/vav-511-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-539-reheat-coil-air-in"
- },
- {
- "@id": "urn:ex/vav-539-reheat-coil-air-out"
- },
- {
- "@id": "urn:ex/vav-539-reheat-coil-water-in"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-539-reheat-coil-water-out"
+ "@id": "urn:ex/vav-511-air-out"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "urn:ex/vav-511-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/room-114-in",
+ "@id": "urn:ex/vav-501-reheat-coil-air-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-112-114"
+ "@id": "urn:ex/connection-to-room-102"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/room-305",
- "@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
- ],
- "http://data.ashrae.org/standard223#encloses": [
- {
- "@id": "urn:ex/room-305-hvac-domain"
- }
- ]
- },
- {
- "@id": "urn:ex/room-102",
- "@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
- ],
- "http://data.ashrae.org/standard223#encloses": [
- {
- "@id": "urn:ex/room-102-hvac-domain"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-501-colder-supply-air-requests",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
- }
- ]
- },
- {
- "@id": "urn:ex/room-309-hvac-domain",
- "@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/room-309-in"
+ "@id": "urn:ex/vav-501-heating-pid-output"
},
{
- "@id": "urn:ex/room-309-out"
+ "@id": "urn:ex/vav-501-more-heat-requests"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "urn:ex/vav-501-air-out"
}
]
},
{
- "@id": "urn:ex/vav-535-reheat-coil-water-out",
+ "@id": "urn:ex/connection-to-room-106-107",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-535-pipe-hot-water-return-before-valve"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-525-air-out",
+ "@id": "urn:ex/vav-521-reheat-coil-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-211"
+ "@id": "urn:ex/connection-to-room-204-205"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -16825,293 +16757,252 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-525-discharge-air-flow"
- },
- {
- "@id": "urn:ex/vav-525-discharge-air-flow-setpoint"
+ "@id": "urn:ex/vav-521-heating-pid-output"
},
{
- "@id": "urn:ex/vav-525-discharge-air-temp"
- },
+ "@id": "urn:ex/vav-521-more-heat-requests"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-525-discharge-air-temp-setpoint"
+ "@id": "urn:ex/vav-521-air-out"
}
]
},
{
- "@id": "urn:ex/vav-509-reheat-coil-valve",
+ "@id": "urn:ex/vav-514-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-509-reheat-coil-valve-in"
- },
- {
- "@id": "urn:ex/vav-509-reheat-coil-valve-out"
+ "@id": "urn:ex/vav-514-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-509-reheat-coil-valve-command"
- },
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-509-reheat-coil-valve-position"
+ "@id": "urn:ex/vav-514-hot-water-in"
}
]
},
{
- "@id": "urn:ex/vav-529",
+ "@id": "urn:ex/vav-523-air-out",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-529-air-in"
- },
- {
- "@id": "urn:ex/vav-529-air-out"
- },
- {
- "@id": "urn:ex/vav-529-hot-water-in"
- },
- {
- "@id": "urn:ex/vav-529-hot-water-out"
+ "@id": "urn:ex/connection-to-room-206"
}
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/vav-529-damper"
- },
- {
- "@id": "urn:ex/vav-529-reheat-coil"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-529-reheat-coil-valve"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/vav-509-damper",
- "@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-509-damper-in"
+ "@id": "urn:ex/vav-523-discharge-air-flow"
},
{
- "@id": "urn:ex/vav-509-damper-out"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "@id": "urn:ex/vav-523-discharge-air-flow-setpoint"
+ },
{
- "@id": "urn:ex/vav-509-damper-command"
+ "@id": "urn:ex/vav-523-discharge-air-temp"
},
{
- "@id": "urn:ex/vav-509-damper-position"
+ "@id": "urn:ex/vav-523-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/vav-520-discharge-air-temp",
+ "@id": "urn:ex/zone-203-occupancy-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/room-203-hvac-domain"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/zone-203-occupancy"
}
]
},
{
- "@id": "urn:ex/vav-508-discharge-air-flow",
+ "@id": "urn:ex/room-208-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "@id": "urn:ex/room-208-in"
+ },
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:ex/room-208-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-507-damper-actuator",
+ "@id": "urn:ex/vav-530-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-507-damper"
+ "@id": "urn:ex/vav-530-air-in"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-507-damper-command"
+ "@id": "urn:ex/vav-530-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/zone-312-occupancy",
+ "@id": "urn:ex/vav-517-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "urn:ex/vav-517-duct-after-damper"
}
- ]
- },
- {
- "@id": "urn:ex/vav-526-damper-command",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/vav-517-colder-supply-air-requests"
+ },
+ {
+ "@id": "urn:ex/vav-517-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/room-207-hvac-domain",
+ "@id": "urn:ex/vav-525-reheat-coil-valve-out",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-207-in"
- },
+ "@id": "urn:ex/vav-525-hot-water-out-connection"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/room-207-out"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "urn:ex/vav-525-hot-water-out"
}
]
},
{
- "@id": "urn:ex/vav-505-reheat-coil-water-out",
+ "@id": "urn:ex/zone-303-304-306-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-505-pipe-hot-water-return-before-valve"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-534-hot-water-out",
+ "@id": "urn:ex/room-210-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-534-hot-water-out-connection"
+ "@id": "urn:ex/connection-to-room-210"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-504-reheat-coil-valve-position",
+ "@id": "urn:ex/zone-309-310-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-519-discharge-air-flow-sensor",
+ "@id": "urn:ex/vav-509-reheat-coil-valve-out",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-519-air-in"
+ "@id": "urn:ex/vav-509-hot-water-out-connection"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-519-discharge-air-flow"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-509-hot-water-out"
}
]
},
{
- "@id": "urn:ex/vav-508-damper-in",
+ "@id": "urn:ex/room-108-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-508-air-in"
- }
]
},
{
- "@id": "urn:ex/vav-531-discharge-air-flow-setpoint",
+ "@id": "urn:ex/vav-501-discharge-air-flow-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -17127,100 +17018,105 @@
]
},
{
- "@id": "urn:ex/vav-532-hot-water-in",
+ "@id": "urn:ex/zone-112-114-occupancy-sensor",
+ "@type": [
+ "http://data.ashrae.org/standard223#Sensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "urn:ex/room-112-hvac-domain"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:ex/zone-112-114-occupancy"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/room-215-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-532-hot-water-in-connection"
+ "@id": "urn:ex/connection-to-room-215"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/zone-307-308-heating-setpoint",
+ "@id": "urn:ex/vav-520-cooling-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-513-damper",
+ "@id": "urn:ex/vav-532-hot-water-in-connection",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-513-damper-in"
- },
- {
- "@id": "urn:ex/vav-513-damper-out"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-513-damper-command"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-513-damper-position"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/zone-116-117-temp-sensor",
+ "@id": "urn:ex/zone-301-temp-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/room-116-hvac-domain"
+ "@id": "urn:ex/room-301-hvac-domain"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/zone-116-117-temp"
+ "@id": "urn:ex/zone-301-temp"
}
]
},
{
- "@id": "urn:ex/vav-512-air-in",
+ "@id": "urn:ex/vav-502-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-502-air-in"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-502-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/vav-531-damper-out",
+ "@id": "urn:ex/vav-514-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-531-duct-after-damper"
+ "@id": "urn:ex/connection-to-room-115"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -17230,63 +17126,86 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-531-colder-supply-air-requests"
+ "@id": "urn:ex/vav-514-discharge-air-flow"
},
{
- "@id": "urn:ex/vav-531-cooling-pid-output"
+ "@id": "urn:ex/vav-514-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-514-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-514-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/vav-540",
+ "@id": "urn:ex/office-ahu-duct-after-clg-coil",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-540-air-in"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-540-air-out"
- },
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-507-damper-command",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-540-hot-water-in"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-540-hot-water-out"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-512-discharge-air-temp",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/vav-540-damper"
- },
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-540-reheat-coil"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-540-reheat-coil-valve"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-502-damper-actuator",
+ "@id": "urn:ex/zone-102-cooling-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-502-damper"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-502-damper-command"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/zone-211-cooling-setpoint",
+ "@id": "urn:ex/zone-203-heating-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -17302,245 +17221,239 @@
]
},
{
- "@id": "urn:ex/connection-to-room-215",
+ "@id": "urn:ex/vav-524-hot-water-out-connection",
"@type": [
"http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-532-colder-supply-air-requests",
+ "@id": "urn:ex/room-314-in",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/connection-to-room-314"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/zone-309-310-window-switch-on-off",
+ "@id": "urn:ex/vav-529-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "urn:ex/vav-529-air-in"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:ex/vav-529-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/vav-502-discharge-air-flow-setpoint",
+ "@id": "urn:ex/vav-536-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/zone-101-cooling-setpoint",
+ "@id": "urn:ex/vav-517-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-517-damper"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-517-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-534-reheat-coil-water-in",
+ "@id": "urn:ex/vav-519-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-534-hot-water-in-connection"
+ "@id": "urn:ex/vav-519-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/office-ahu-air-filter",
+ "@type": [
+ "http://data.ashrae.org/standard223#AirFilter",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Filter"
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-534-hot-water-in"
+ "@id": "urn:ex/office-ahu-air-filter-in"
+ },
+ {
+ "@id": "urn:ex/office-ahu-air-filter-out"
}
]
},
{
- "@id": "urn:ex/vav-524-damper-actuator",
+ "@id": "urn:ex/vav-520-damper-actuator",
"@type": [
"http://data.ashrae.org/standard223#Actuator"
],
"http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/vav-524-damper"
+ "@id": "urn:ex/vav-520-damper"
}
],
"http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/vav-524-damper-command"
+ "@id": "urn:ex/vav-520-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-535-reheat-coil-valve-position",
+ "@id": "urn:ex/zone-202-occupancy",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
]
},
{
- "@id": "urn:ex/room-310-in",
+ "@id": "urn:ex/vav-515-reheat-coil-air-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-309-310"
+ "@id": "urn:ex/connection-to-room-116-117"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/vav-539-reheat-coil-valve-out",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-539-hot-water-out-connection"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:ex/vav-515-heating-pid-output"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-515-more-heat-requests"
}
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-539-hot-water-out"
+ "@id": "urn:ex/vav-515-air-out"
}
]
},
{
- "@id": "urn:ex/vav-506-air-in",
+ "@id": "urn:ex/vav-507-reheat-coil-valve-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-507-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-507-hot-water-out"
}
]
},
{
- "@id": "urn:ex/vav-518-reheat-coil-valve-position",
+ "@id": "urn:ex/vav-534-discharge-air-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
- }
- ]
- },
- {
- "@id": "urn:ex/zone-110-occupancy-override",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-516-damper-position",
+ "@id": "urn:ex/zone-210-temp",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-511-damper",
+ "@id": "urn:ex/vav-510-reheat-coil-valve-command",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-511-damper-in"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-511-damper-out"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-511-damper-command"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-511-damper-position"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-536-more-heat-requests",
+ "@id": "urn:ex/vav-529-more-heat-requests",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
@@ -17551,216 +17464,230 @@
]
},
{
- "@id": "urn:ex/vav-534-colder-supply-air-requests",
+ "@id": "urn:ex/vav-519-discharge-air-flow",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
- ]
- },
- {
- "@id": "urn:ex/vav-505-reheat-coil-valve-in",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-505-pipe-hot-water-return-before-valve"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-501-heating-pid-output",
+ "@id": "urn:ex/vav-523-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/vav-523-air-in"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "urn:ex/vav-523-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/vav-528-more-heat-requests",
+ "@id": "urn:ex/zone-211-occupancy-override",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
]
},
{
- "@id": "urn:ex/vav-515-more-heat-requests",
+ "@id": "urn:ex/vav-506-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/vav-506-reheat-coil-valve-in"
+ },
+ {
+ "@id": "urn:ex/vav-506-reheat-coil-valve-out"
}
- ]
- },
- {
- "@id": "urn:ex/vav-525-colder-supply-air-requests",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-506-reheat-coil-valve-command"
+ },
+ {
+ "@id": "urn:ex/vav-506-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-533-reheat-coil",
+ "@id": "urn:ex/vav-505-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-533-reheat-coil-air-in"
- },
- {
- "@id": "urn:ex/vav-533-reheat-coil-air-out"
- },
+ "@id": "urn:ex/vav-505-pipe-hot-water-return-before-valve"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-533-reheat-coil-water-in"
- },
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-301-occupancy-sensor",
+ "@type": [
+ "http://data.ashrae.org/standard223#Sensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-533-reheat-coil-water-out"
+ "@id": "urn:ex/room-301-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "urn:ex/zone-301-occupancy"
}
]
},
{
- "@id": "urn:ex/vav-535-discharge-air-temp-sensor",
+ "@id": "urn:ex/vav-532-discharge-air-temp-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-535-air-out"
+ "@id": "urn:ex/vav-532-air-out"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-535-discharge-air-temp"
+ "@id": "urn:ex/vav-532-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/vav-522-reheat-coil-air-out",
+ "@id": "urn:ex/zone-112-114-occupancy-override",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/connection-to-room-208-209"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-305",
+ "@type": [
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/room-305-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-522-heating-pid-output"
- },
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:ex/vav-522-more-heat-requests"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-522-air-out"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-535-reheat-coil",
- "@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
- ],
- "http://data.ashrae.org/standard223#cnx": [
+ "@id": "urn:ex/zone-305-cooling-setpoint"
+ },
{
- "@id": "urn:ex/vav-535-reheat-coil-air-in"
+ "@id": "urn:ex/zone-305-heating-setpoint"
},
{
- "@id": "urn:ex/vav-535-reheat-coil-air-out"
+ "@id": "urn:ex/zone-305-occupancy"
},
{
- "@id": "urn:ex/vav-535-reheat-coil-water-in"
+ "@id": "urn:ex/zone-305-occupancy-override"
},
{
- "@id": "urn:ex/vav-535-reheat-coil-water-out"
- }
- ],
- "http://data.ashrae.org/standard223#hasRole": [
+ "@id": "urn:ex/zone-305-temp"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "urn:ex/zone-305-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-538-reheat-coil-air-out",
+ "@id": "urn:ex/vav-501-air-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-213"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-106-107-occupancy-sensor",
+ "@type": [
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-538-heating-pid-output"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-538-more-heat-requests"
+ "@id": "urn:ex/room-106-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-538-air-out"
+ "@id": "urn:ex/zone-106-107-occupancy"
}
]
},
{
- "@id": "urn:ex/vav-524-hot-water-out",
+ "@id": "urn:ex/vav-505-reheat-coil-air-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-524-hot-water-out-connection"
+ "@id": "urn:ex/vav-505-duct-after-damper"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-529-pipe-hot-water-return-before-valve",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -17769,18 +17696,18 @@
]
},
{
- "@id": "urn:ex/office-ahu-clg-coil-valve-position",
+ "@id": "urn:ex/vav-530-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-530-hot-water-out-connection"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
@@ -17801,25 +17728,29 @@
]
},
{
- "@id": "urn:ex/vav-517-hot-water-out-connection",
+ "@id": "urn:ex/vav-512-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-512-air-in"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:ex/vav-512-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/vav-519-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-527-hot-water-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-519-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-527-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -17829,421 +17760,480 @@
]
},
{
- "@id": "urn:ex/vav-520-hot-water-in-connection",
+ "@id": "urn:ex/vav-523-heating-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-508-reheat-coil-air-out",
+ "@id": "urn:ex/zone-301-window-switch-on-off",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/connection-to-room-109"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/office-ahu-oa-temp",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Role-Outside"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-508-heating-pid-output"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-508-more-heat-requests"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-508-air-out"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-506-discharge-air-flow-sensor",
+ "@id": "urn:ex/zone-203-temp",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-506-air-in"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-506-discharge-air-flow"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/room-312",
+ "@id": "urn:ex/zone-110-occupancy",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/room-312-hvac-domain"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
]
},
{
- "@id": "urn:ex/zone-109-window-switch-on-off",
+ "@id": "urn:ex/vav-513-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/room-209-in",
+ "@id": "urn:ex/zone-213-cooling-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/connection-to-room-208-209"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/zone-307-308-occupancy-sensor",
+ "@id": "urn:ex/zone-312-temp-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/room-307-hvac-domain"
+ "@id": "urn:ex/room-312-hvac-domain"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/zone-307-308-occupancy"
+ "@id": "urn:ex/zone-312-temp"
}
]
},
{
- "@id": "urn:ex/vav-505-air-in",
+ "@id": "urn:ex/vav-533-cooling-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-531-discharge-air-flow",
+ "@id": "urn:ex/vav-504-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ "@id": "urn:ex/vav-504-reheat-coil-valve-in"
+ },
+ {
+ "@id": "urn:ex/vav-504-reheat-coil-valve-out"
}
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:ex/vav-504-reheat-coil-valve-command"
+ },
+ {
+ "@id": "urn:ex/vav-504-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/zone-116-117-cooling-setpoint",
+ "@id": "urn:ex/room-208-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/connection-to-room-208-209"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/zone-211-temp",
+ "@id": "urn:ex/vav-524-damper",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-524-damper-in"
+ },
+ {
+ "@id": "urn:ex/vav-524-damper-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-524-damper-command"
+ },
+ {
+ "@id": "urn:ex/vav-524-damper-position"
}
]
},
{
- "@id": "urn:ex/vav-533-reheat-coil-valve-actuator",
+ "@id": "urn:ex/connection-to-room-302",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
- ],
- "http://data.ashrae.org/standard223#actuates": [
- {
- "@id": "urn:ex/vav-533-reheat-coil-valve"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-533-reheat-coil-valve-command"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-522-discharge-air-flow",
+ "@id": "urn:ex/vav-509-reheat-coil-air-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ "@id": "urn:ex/connection-to-room-113"
}
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:ex/vav-509-heating-pid-output"
+ },
+ {
+ "@id": "urn:ex/vav-509-more-heat-requests"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-509-air-out"
}
]
},
{
- "@id": "urn:ex/vav-539-air-out",
+ "@id": "urn:ex/vav-511-reheat-coil-valve-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-214"
+ "@id": "urn:ex/vav-511-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-539-discharge-air-flow"
- },
+ "@id": "urn:ex/vav-511-hot-water-out"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/room-314-hvac-domain",
+ "@type": [
+ "http://data.ashrae.org/standard223#DomainSpace"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-539-discharge-air-flow-setpoint"
+ "@id": "urn:ex/room-314-in"
},
{
- "@id": "urn:ex/vav-539-discharge-air-temp"
- },
+ "@id": "urn:ex/room-314-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:ex/vav-539-discharge-air-temp-setpoint"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/zone-118-cooling-setpoint",
+ "@id": "urn:ex/vav-506-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-506-reheat-coil-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-506-reheat-coil-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-506-reheat-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-506-reheat-coil-water-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/zone-115",
+ "@id": "urn:ex/office-ahu-sa-out",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-115-hvac-domain"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/zone-115-cooling-setpoint"
+ "@id": "urn:ex/office-ahu-colder-supply-air-requests"
},
{
- "@id": "urn:ex/zone-115-heating-setpoint"
+ "@id": "urn:ex/office-ahu-increased-air-pressure-requests"
},
{
- "@id": "urn:ex/zone-115-occupancy"
+ "@id": "urn:ex/office-ahu-sa-temp"
},
{
- "@id": "urn:ex/zone-115-occupancy-override"
+ "@id": "urn:ex/office-ahu-sa-temp-setpoint"
},
{
- "@id": "urn:ex/zone-115-temp"
+ "@id": "urn:ex/office-ahu-supply-duct-static-pressure"
},
{
- "@id": "urn:ex/zone-115-window-switch-on-off"
+ "@id": "urn:ex/office-ahu-supply-duct-static-pressure-setpoint"
+ },
+ {
+ "@id": "urn:ex/office-ahu-warmer-supply-air-requests"
}
]
},
{
- "@id": "urn:ex/zone-108-temp",
+ "@id": "urn:ex/vav-518-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-518-air-in"
}
]
},
{
- "@id": "urn:ex/vav-535",
+ "@id": "urn:ex/office-ahu-ra-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-535-air-in"
- },
- {
- "@id": "urn:ex/vav-535-air-out"
- },
- {
- "@id": "urn:ex/vav-535-hot-water-in"
- },
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/vav-535-hot-water-out"
+ "@id": "urn:ex/office-ahu-ra-damper"
}
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/vav-535-damper"
- },
- {
- "@id": "urn:ex/vav-535-reheat-coil"
- },
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/vav-535-reheat-coil-valve"
+ "@id": "urn:ex/office-ahu-ra-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-519-discharge-air-temp-sensor",
+ "@id": "urn:ex/vav-515-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-519-air-out"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-519-discharge-air-temp"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-539-duct-after-damper",
+ "@id": "urn:ex/zone-204-205-occupancy",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
]
},
{
- "@id": "urn:ex/vav-538-reheat-coil",
+ "@id": "urn:ex/vav-516-reheat-coil-valve-position",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-538-reheat-coil-air-in"
- },
- {
- "@id": "urn:ex/vav-538-reheat-coil-air-out"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-538-reheat-coil-water-in"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-538-reheat-coil-water-out"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-109-occupancy-override",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
]
},
{
- "@id": "urn:ex/vav-505-duct-after-damper",
+ "@id": "urn:ex/vav-518-air-out",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/connection-to-room-202"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-518-discharge-air-flow"
+ },
+ {
+ "@id": "urn:ex/vav-518-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-518-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-518-discharge-air-temp-setpoint"
+ }
]
},
{
- "@id": "urn:ex/zone-111-heating-setpoint",
+ "@id": "urn:ex/zone-202-heating-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -18259,18 +18249,18 @@
]
},
{
- "@id": "urn:ex/zone-201-window-switch-on-off",
+ "@id": "urn:ex/room-109",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "urn:ex/room-109-hvac-domain"
}
]
},
{
- "@id": "urn:ex/vav-537-reheat-coil-valve-command",
+ "@id": "urn:ex/vav-511-damper-command",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -18286,470 +18276,474 @@
]
},
{
- "@id": "urn:ex/zone-108-window-switch-on-off",
+ "@id": "urn:ex/vav-510",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "urn:ex/vav-510-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-510-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-510-hot-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-510-hot-water-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#contains": [
+ {
+ "@id": "urn:ex/vav-510-damper"
+ },
+ {
+ "@id": "urn:ex/vav-510-reheat-coil"
+ },
+ {
+ "@id": "urn:ex/vav-510-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/vav-508-discharge-air-temp-setpoint",
+ "@id": "urn:ex/vav-538-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-538-air-in"
}
]
},
{
- "@id": "urn:ex/vav-510-discharge-air-temp-sensor",
+ "@id": "urn:ex/room-215-out",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-510-air-out"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-510-discharge-air-temp"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-505-discharge-air-flow-setpoint",
+ "@id": "urn:ex/vav-507-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-534-reheat-coil-valve-command",
+ "@id": "urn:ex/zone-207-cooling-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-530-discharge-air-temp",
+ "@id": "urn:ex/zone-102-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/room-102-hvac-domain"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/zone-102-temp"
}
]
},
{
- "@id": "urn:ex/room-205-hvac-domain",
+ "@id": "urn:ex/vav-523-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-205-in"
- },
+ "@id": "urn:ex/vav-523-duct-after-damper"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/room-205-out"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "urn:ex/vav-523-colder-supply-air-requests"
+ },
+ {
+ "@id": "urn:ex/vav-523-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/vav-535-discharge-air-temp-setpoint",
+ "@id": "urn:ex/vav-506-air-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/connection-to-room-106-107"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/room-105",
- "@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/room-105-hvac-domain"
+ "@id": "urn:ex/vav-506-discharge-air-flow"
+ },
+ {
+ "@id": "urn:ex/vav-506-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-506-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-506-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/zone-118-occupancy",
+ "@id": "urn:ex/vav-523-colder-supply-air-requests",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-508-reheat-coil-water-out",
+ "@id": "urn:ex/vav-512-reheat-coil-air-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-508-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-512-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-540-discharge-air-temp-sensor",
+ "@id": "urn:ex/vav-530-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/vav-540-air-out"
+ "@id": "urn:ex/vav-530-damper"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/vav-540-discharge-air-temp"
+ "@id": "urn:ex/vav-530-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-512-discharge-air-flow",
+ "@id": "urn:ex/vav-523-reheat-coil-air-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:ex/vav-523-duct-after-damper"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/zone-305-occupancy-override",
+ "@id": "urn:ex/vav-501-hot-water-in",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "urn:ex/vav-501-hot-water-in-connection"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-508-reheat-coil-valve-position",
+ "@id": "urn:ex/vav-534-discharge-air-flow-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/room-113",
+ "@id": "urn:ex/zone-101-occupancy-sensor",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/room-113-hvac-domain"
+ "@id": "urn:ex/room-101-hvac-domain"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:ex/zone-101-occupancy"
}
]
},
{
- "@id": "urn:ex/zone-201",
+ "@id": "urn:ex/room-205",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
- ],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/room-201-hvac-domain"
- }
- ],
- "http://data.ashrae.org/standard223#hasDomain": [
- {
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
- }
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/zone-201-cooling-setpoint"
- },
- {
- "@id": "urn:ex/zone-201-heating-setpoint"
- },
- {
- "@id": "urn:ex/zone-201-occupancy"
- },
- {
- "@id": "urn:ex/zone-201-occupancy-override"
- },
- {
- "@id": "urn:ex/zone-201-temp"
- },
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "urn:ex/zone-201-window-switch-on-off"
+ "@id": "urn:ex/room-205-hvac-domain"
}
]
},
{
- "@id": "urn:ex/vav-523-reheat-coil-water-out",
+ "@id": "urn:ex/vav-501-reheat-coil-air-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-523-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-501-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-524-discharge-air-temp",
+ "@id": "urn:ex/office-ahu-oa-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/office-ahu-duct-after-oa-ra-damper"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/office-ahu-ra-damper-actuator",
+ "@id": "urn:ex/vav-535-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-ra-damper"
+ "@id": "urn:ex/vav-535-hot-water-out-connection"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/office-ahu-ra-damper-command"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/zone-212-heating-setpoint",
+ "@id": "urn:ex/zone-307-308-window-switch-on-off",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/vav-526-damper",
+ "@id": "urn:ex/office-ahu-clg-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#ChilledWaterValve"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-526-damper-in"
+ "@id": "urn:ex/office-ahu-clg-coil-valve-in"
},
{
- "@id": "urn:ex/vav-526-damper-out"
+ "@id": "urn:ex/office-ahu-clg-coil-valve-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-ChilledWater"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-526-damper-command"
+ "@id": "urn:ex/office-ahu-clg-coil-valve-command"
},
{
- "@id": "urn:ex/vav-526-damper-position"
+ "@id": "urn:ex/office-ahu-clg-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-528-damper-command",
+ "@id": "urn:ex/vav-518-more-heat-requests",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-507-reheat-coil-valve-command",
+ "@id": "urn:ex/zone-104-cooling-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-540-damper-command",
+ "@id": "urn:ex/vav-526-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-526-air-in"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/vav-526-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/vav-529-reheat-coil",
+ "@id": "urn:ex/office-ahu-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-529-reheat-coil-air-in"
- },
- {
- "@id": "urn:ex/vav-529-reheat-coil-air-out"
- },
+ "@id": "urn:ex/office-ahu-hot-water-out-connection"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-529-reheat-coil-water-in"
- },
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-532-cooling-pid-output",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-529-reheat-coil-water-out"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-505-discharge-air-flow-sensor",
+ "@id": "urn:ex/vav-529-reheat-coil-valve-position",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-505-air-in"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-505-discharge-air-flow"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-540-discharge-air-flow",
+ "@id": "urn:ex/vav-507-discharge-air-flow",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -18770,23 +18764,23 @@
]
},
{
- "@id": "urn:ex/vav-532-discharge-air-flow-sensor",
+ "@id": "urn:ex/vav-509-reheat-coil-air-in",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-532-air-in"
+ "@id": "urn:ex/vav-509-duct-after-damper"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-532-discharge-air-flow"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-503-colder-supply-air-requests",
+ "@id": "urn:ex/vav-506-colder-supply-air-requests",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
@@ -18797,9 +18791,14 @@
]
},
{
- "@id": "urn:ex/zone-113-cooling-setpoint",
+ "@id": "urn:ex/office-ahu-sa-temp",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasAspect": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Supply"
+ }
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -18813,7 +18812,31 @@
]
},
{
- "@id": "urn:ex/vav-536-hot-water-in-connection",
+ "@id": "urn:ex/vav-503-damper-out",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-503-duct-after-damper"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-503-colder-supply-air-requests"
+ },
+ {
+ "@id": "urn:ex/vav-503-cooling-pid-output"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-526-pipe-hot-water-return-before-valve",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Pipe"
@@ -18825,110 +18848,112 @@
]
},
{
- "@id": "urn:ex/room-302",
+ "@id": "urn:ex/vav-509-cooling-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-302-hvac-domain"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-538-hot-water-out-connection",
+ "@id": "urn:ex/office-ahu-supply-duct-static-pressure",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasAspect": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Supply"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ }
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/IN_H2O"
}
]
},
{
- "@id": "urn:ex/vav-516-reheat-coil-valve-command",
+ "@id": "urn:ex/vav-508-cooling-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-525-reheat-coil",
+ "@id": "urn:ex/zone-113-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-525-reheat-coil-air-in"
- },
- {
- "@id": "urn:ex/vav-525-reheat-coil-air-out"
- },
- {
- "@id": "urn:ex/vav-525-reheat-coil-water-in"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-525-reheat-coil-water-out"
+ "@id": "urn:ex/room-113-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "urn:ex/zone-113-temp"
}
]
},
{
- "@id": "urn:ex/room-208-out",
+ "@id": "urn:ex/vav-510-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/connection-to-room-111"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/zone-210-occupancy-sensor",
- "@type": [
- "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/room-210-hvac-domain"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
+ "@id": "urn:ex/vav-510-discharge-air-flow"
+ },
{
- "@id": "urn:ex/zone-210-occupancy"
+ "@id": "urn:ex/vav-510-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-510-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-510-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/room-307-in",
+ "@id": "urn:ex/room-214-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-307-308"
+ "@id": "urn:ex/connection-to-room-214"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -18938,328 +18963,387 @@
]
},
{
- "@id": "urn:ex/zone-208-209-temp",
+ "@id": "urn:ex/vav-516-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-516-duct-after-damper"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/room-307",
- "@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/room-307-hvac-domain"
+ "@id": "urn:ex/vav-516-colder-supply-air-requests"
+ },
+ {
+ "@id": "urn:ex/vav-516-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/vav-523-cooling-pid-output",
+ "@id": "urn:ex/vav-523-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/vav-523-hot-water-in-connection"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-523-hot-water-in"
}
]
},
{
- "@id": "urn:ex/vav-520-heating-pid-output",
+ "@id": "urn:ex/vav-535-discharge-air-temp",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
- ]
- },
- {
- "@id": "urn:ex/vav-530-colder-supply-air-requests",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-527-discharge-air-flow-setpoint",
+ "@id": "urn:ex/vav-531-pipe-hot-water-return-before-valve",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-506-damper-out",
+ "@id": "urn:ex/zone-206",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/vav-506-duct-after-damper"
+ "@id": "urn:ex/room-206-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-506-colder-supply-air-requests"
+ "@id": "urn:ex/zone-206-co2-concentration"
},
{
- "@id": "urn:ex/vav-506-cooling-pid-output"
+ "@id": "urn:ex/zone-206-co2-concentration-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-206-cooling-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-206-heating-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-206-occupancy"
+ },
+ {
+ "@id": "urn:ex/zone-206-occupancy-override"
+ },
+ {
+ "@id": "urn:ex/zone-206-temp"
+ },
+ {
+ "@id": "urn:ex/zone-206-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/room-105-out",
+ "@id": "urn:ex/vav-530-reheat-coil-valve-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/vav-530-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-530-hot-water-out"
}
]
},
{
- "@id": "urn:ex/room-208-hvac-domain",
+ "@id": "urn:ex/vav-534-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-208-in"
+ "@id": "urn:ex/vav-534-reheat-coil-valve-in"
},
{
- "@id": "urn:ex/room-208-out"
+ "@id": "urn:ex/vav-534-reheat-coil-valve-out"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
}
- ]
- },
- {
- "@id": "urn:ex/vav-511-air-in",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:ex/vav-534-reheat-coil-valve-command"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-534-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-503-reheat-coil-valve",
+ "@id": "urn:ex/zone-118",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-503-reheat-coil-valve-in"
- },
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/vav-503-reheat-coil-valve-out"
+ "@id": "urn:ex/room-118-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-503-reheat-coil-valve-command"
+ "@id": "urn:ex/zone-118-cooling-setpoint"
},
{
- "@id": "urn:ex/vav-503-reheat-coil-valve-position"
+ "@id": "urn:ex/zone-118-heating-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-118-occupancy"
+ },
+ {
+ "@id": "urn:ex/zone-118-occupancy-override"
+ },
+ {
+ "@id": "urn:ex/zone-118-temp"
+ },
+ {
+ "@id": "urn:ex/zone-118-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/zone-213-occupancy",
+ "@id": "urn:ex/vav-524-more-heat-requests",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-522-hot-water-out-connection",
+ "@id": "urn:ex/vav-530-discharge-air-flow-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-535-reheat-coil-air-in",
+ "@id": "urn:ex/vav-536-damper",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-535-duct-after-damper"
+ "@id": "urn:ex/vav-536-damper-in"
+ },
+ {
+ "@id": "urn:ex/vav-536-damper-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-536-damper-command"
+ },
+ {
+ "@id": "urn:ex/vav-536-damper-position"
}
]
},
{
- "@id": "urn:ex/vav-529-hot-water-in",
+ "@id": "urn:ex/vav-524-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/vav-529-hot-water-in-connection"
+ "@id": "urn:ex/vav-524-damper"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-524-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-517-reheat-coil-air-in",
+ "@id": "urn:ex/vav-514-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-517-duct-after-damper"
+ "@id": "urn:ex/vav-514-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-538-discharge-air-temp",
+ "@id": "urn:ex/vav-528-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-528-damper"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-528-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-531-damper-in",
+ "@id": "urn:ex/vav-540-damper",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-540-damper-in"
+ },
+ {
+ "@id": "urn:ex/vav-540-damper-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-540-damper-command"
+ },
+ {
+ "@id": "urn:ex/vav-540-damper-position"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-532-hot-water-out-connection",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-531-air-in"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/room-201-hvac-domain",
+ "@id": "urn:ex/zone-112-114",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/room-201-in"
+ "@id": "urn:ex/room-112-hvac-domain"
},
{
- "@id": "urn:ex/room-201-out"
+ "@id": "urn:ex/room-114-hvac-domain"
}
],
"http://data.ashrae.org/standard223#hasDomain": [
{
"@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/zone-112-114-cooling-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-112-114-heating-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-112-114-occupancy"
+ },
+ {
+ "@id": "urn:ex/zone-112-114-occupancy-override"
+ },
+ {
+ "@id": "urn:ex/zone-112-114-temp"
+ },
+ {
+ "@id": "urn:ex/zone-112-114-window-switch-on-off"
+ }
]
},
{
- "@id": "urn:ex/zone-104-occupancy",
+ "@id": "urn:ex/zone-309-310-occupancy",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
@@ -19270,31 +19354,30 @@
]
},
{
- "@id": "urn:ex/vav-540-discharge-air-temp",
+ "@id": "urn:ex/vav-506-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-506-pipe-hot-water-return-before-valve"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-530-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/vav-532-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-532-pipe-hot-water-return-before-valve"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -19303,69 +19386,93 @@
]
},
{
- "@id": "urn:ex/vav-512-damper-out",
+ "@id": "urn:ex/zone-109-occupancy",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-512-duct-after-damper"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-539-damper",
+ "@type": [
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-539-damper-in"
+ },
+ {
+ "@id": "urn:ex/vav-539-damper-out"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-512-colder-supply-air-requests"
+ "@id": "urn:ex/vav-539-damper-command"
},
{
- "@id": "urn:ex/vav-512-cooling-pid-output"
+ "@id": "urn:ex/vav-539-damper-position"
}
]
},
{
- "@id": "urn:ex/zone-108-heating-setpoint",
+ "@id": "urn:ex/vav-520-reheat-coil-valve-command",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-525-reheat-coil-valve-position",
+ "@id": "urn:ex/vav-515-air-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/connection-to-room-116-117"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-515-discharge-air-flow"
+ },
+ {
+ "@id": "urn:ex/vav-515-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-515-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-515-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/vav-510-hot-water-out",
+ "@id": "urn:ex/vav-525-hot-water-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-510-hot-water-out-connection"
+ "@id": "urn:ex/vav-525-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -19375,109 +19482,92 @@
]
},
{
- "@id": "urn:ex/vav-534-reheat-coil-valve",
+ "@id": "urn:ex/zone-210-occupancy",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-534-reheat-coil-valve-in"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-307-308",
+ "@type": [
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
+ ],
+ "http://data.ashrae.org/standard223#contains": [
+ {
+ "@id": "urn:ex/room-307-hvac-domain"
},
{
- "@id": "urn:ex/vav-534-reheat-coil-valve-out"
+ "@id": "urn:ex/room-308-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-534-reheat-coil-valve-command"
+ "@id": "urn:ex/zone-307-308-cooling-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-307-308-heating-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-307-308-occupancy"
+ },
+ {
+ "@id": "urn:ex/zone-307-308-occupancy-override"
+ },
+ {
+ "@id": "urn:ex/zone-307-308-temp"
},
{
- "@id": "urn:ex/vav-534-reheat-coil-valve-position"
- }
- ]
- },
- {
- "@id": "urn:ex/zone-112-114-occupancy-override",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "urn:ex/zone-307-308-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-527-discharge-air-flow",
+ "@id": "urn:ex/vav-513-cooling-pid-output",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
- ],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
- }
- ]
- },
- {
- "@id": "urn:ex/connection-to-room-113",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/office-ahu-ra-damper",
+ "@id": "urn:ex/zone-211-occupancy-sensor",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/office-ahu-ra-damper-in"
- },
- {
- "@id": "urn:ex/office-ahu-ra-damper-out"
- }
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/office-ahu-ra-damper-command"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/office-ahu-ra-damper-position"
+ "@id": "urn:ex/room-211-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Return"
+ "@id": "urn:ex/zone-211-occupancy"
}
]
},
{
- "@id": "urn:ex/vav-535-damper-command",
+ "@id": "urn:ex/vav-523-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -19491,137 +19581,174 @@
]
},
{
- "@id": "urn:ex/vav-523",
+ "@id": "urn:ex/vav-527",
"@type": [
"http://data.ashrae.org/standard223#SingleDuctTerminal",
"http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-523-air-in"
+ "@id": "urn:ex/vav-527-air-in"
},
{
- "@id": "urn:ex/vav-523-air-out"
+ "@id": "urn:ex/vav-527-air-out"
},
{
- "@id": "urn:ex/vav-523-hot-water-in"
+ "@id": "urn:ex/vav-527-hot-water-in"
},
{
- "@id": "urn:ex/vav-523-hot-water-out"
+ "@id": "urn:ex/vav-527-hot-water-out"
}
],
"http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/vav-523-damper"
+ "@id": "urn:ex/vav-527-damper"
},
{
- "@id": "urn:ex/vav-523-reheat-coil"
+ "@id": "urn:ex/vav-527-reheat-coil"
},
{
- "@id": "urn:ex/vav-523-reheat-coil-valve"
+ "@id": "urn:ex/vav-527-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/office-ahu-ea-damper-actuator",
+ "@id": "urn:ex/vav-530-heating-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/office-ahu-ea-damper"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/office-ahu-ea-damper-command"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-519-damper-command",
+ "@id": "urn:ex/room-301-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/connection-to-room-301"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-511-reheat-coil-water-in",
+ "@id": "urn:ex/zone-314",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/vav-511-hot-water-in-connection"
+ "@id": "urn:ex/room-314-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-511-hot-water-in"
+ "@id": "urn:ex/zone-314-cooling-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-314-heating-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-314-occupancy"
+ },
+ {
+ "@id": "urn:ex/zone-314-occupancy-override"
+ },
+ {
+ "@id": "urn:ex/zone-314-temp"
+ },
+ {
+ "@id": "urn:ex/zone-314-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-537-duct-after-damper",
+ "@id": "urn:ex/vav-510-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-510-pipe-hot-water-return-before-valve"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-519-more-heat-requests",
+ "@id": "urn:ex/vav-516-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/vav-516-pipe-hot-water-return-before-valve"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-512-discharge-air-temp-setpoint",
+ "@id": "urn:ex/vav-518-reheat-coil-valve-command",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-515-damper-in",
+ "@id": "urn:ex/connection-to-room-210",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-525-air-out",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/connection-to-room-211"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -19629,395 +19756,417 @@
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-515-air-in"
+ "@id": "urn:ex/vav-525-discharge-air-flow"
+ },
+ {
+ "@id": "urn:ex/vav-525-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-525-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-525-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/room-309-out",
+ "@id": "urn:ex/vav-519-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/connection-to-room-204-205"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-519-discharge-air-flow"
+ },
+ {
+ "@id": "urn:ex/vav-519-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-519-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-519-discharge-air-temp-setpoint"
+ }
]
},
{
- "@id": "urn:ex/zone-309-310-heating-setpoint",
+ "@id": "urn:ex/vav-527-damper",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-527-damper-in"
+ },
+ {
+ "@id": "urn:ex/vav-527-damper-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-527-damper-command"
+ },
+ {
+ "@id": "urn:ex/vav-527-damper-position"
}
]
},
{
- "@id": "urn:ex/vav-529-hot-water-out",
+ "@id": "urn:ex/vav-505-reheat-coil-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-529-hot-water-out-connection"
+ "@id": "urn:ex/connection-to-room-108"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/vav-527-air-in",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-505-heating-pid-output"
+ },
+ {
+ "@id": "urn:ex/vav-505-more-heat-requests"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-505-air-out"
}
]
},
{
- "@id": "urn:ex/zone-213-occupancy-sensor",
+ "@id": "urn:ex/vav-527-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/room-213-hvac-domain"
+ "@id": "urn:ex/vav-527-reheat-coil-valve"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/zone-213-occupancy"
+ "@id": "urn:ex/vav-527-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/vav-533-air-in",
+ "@id": "urn:ex/vav-525-cooling-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/zone-311-window-switch-on-off",
+ "@id": "urn:ex/room-215",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "urn:ex/room-215-hvac-domain"
}
]
},
{
- "@id": "urn:ex/room-106-out",
+ "@id": "urn:ex/zone-113",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/room-113-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/zone-113-cooling-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-113-heating-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-113-occupancy"
+ },
+ {
+ "@id": "urn:ex/zone-113-occupancy-override"
+ },
+ {
+ "@id": "urn:ex/zone-113-temp"
+ },
+ {
+ "@id": "urn:ex/zone-113-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-501-discharge-air-flow-sensor",
+ "@id": "urn:ex/vav-530-discharge-air-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-501-air-in"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-501-discharge-air-flow"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-526-hot-water-out-connection",
+ "@id": "urn:ex/vav-502-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-502-reheat-coil-valve"
+ }
+ ],
+ "http://data.ashrae.org/standard223#commandedByProperty": [
+ {
+ "@id": "urn:ex/vav-502-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/vav-517-reheat-coil-water-out",
+ "@id": "urn:ex/vav-505-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/vav-517-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-505-damper"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-505-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-514-damper-out",
+ "@id": "urn:ex/office-ahu-htg-coil",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-514-duct-after-damper"
+ "@id": "urn:ex/office-ahu-htg-coil-air-in"
+ },
+ {
+ "@id": "urn:ex/office-ahu-htg-coil-air-out"
+ },
+ {
+ "@id": "urn:ex/office-ahu-htg-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/office-ahu-htg-coil-water-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-314-window-switch-on-off",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-514-colder-supply-air-requests"
- },
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-514-cooling-pid-output"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/vav-535-reheat-coil-valve",
+ "@id": "urn:ex/zone-116-117",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/vav-535-reheat-coil-valve-in"
+ "@id": "urn:ex/room-116-hvac-domain"
},
{
- "@id": "urn:ex/vav-535-reheat-coil-valve-out"
+ "@id": "urn:ex/room-117-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-535-reheat-coil-valve-command"
- },
- {
- "@id": "urn:ex/vav-535-reheat-coil-valve-position"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-528",
- "@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-528-air-in"
+ "@id": "urn:ex/zone-116-117-cooling-setpoint"
},
{
- "@id": "urn:ex/vav-528-air-out"
+ "@id": "urn:ex/zone-116-117-heating-setpoint"
},
{
- "@id": "urn:ex/vav-528-hot-water-in"
+ "@id": "urn:ex/zone-116-117-occupancy"
},
{
- "@id": "urn:ex/vav-528-hot-water-out"
- }
- ],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/vav-528-damper"
+ "@id": "urn:ex/zone-116-117-occupancy-override"
},
{
- "@id": "urn:ex/vav-528-reheat-coil"
+ "@id": "urn:ex/zone-116-117-temp"
},
{
- "@id": "urn:ex/vav-528-reheat-coil-valve"
+ "@id": "urn:ex/zone-116-117-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-518-discharge-air-flow-setpoint",
+ "@id": "urn:ex/room-102-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:ex/connection-to-room-102"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/office-ahu-sa-flow-sensor",
+ "@id": "urn:ex/room-309",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:ex/office-ahu-sa-fan-in"
- }
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "urn:ex/office-ahu-sa-flow"
+ "@id": "urn:ex/room-309-hvac-domain"
}
]
},
{
- "@id": "urn:ex/vav-525-cooling-pid-output",
+ "@id": "urn:ex/vav-517-damper-position",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/room-314",
+ "@id": "urn:ex/zone-102-window-switch-on-off",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/room-314-hvac-domain"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/vav-513-discharge-air-temp-setpoint",
+ "@id": "urn:ex/room-106-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-502-discharge-air-temp-setpoint",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "@id": "urn:ex/room-106-in"
+ },
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/room-106-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-504-damper-in",
+ "@id": "urn:ex/room-308-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/connection-to-room-307-308"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-504-air-in"
- }
]
},
{
- "@id": "urn:ex/vav-521-damper-position",
+ "@id": "urn:ex/zone-113-temp",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-505-reheat-coil-valve-command",
+ "@id": "urn:ex/office-ahu-ra-fan-speed-status",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -20031,41 +20180,42 @@
]
},
{
- "@id": "urn:ex/vav-502-discharge-air-flow",
+ "@id": "urn:ex/office-ahu-duct-after-htg-coil",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-526-reheat-coil-valve-in",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:ex/vav-526-pipe-hot-water-return-before-valve"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/zone-307-308-occupancy-override",
+ "@id": "urn:ex/vav-520-discharge-air-temp",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
- ]
- },
- {
- "@id": "urn:ex/vav-525-discharge-air-temp-setpoint",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -20079,13 +20229,13 @@
]
},
{
- "@id": "urn:ex/vav-511-reheat-coil-air-out",
+ "@id": "urn:ex/vav-540-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-112-114"
+ "@id": "urn:ex/connection-to-room-215"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -20095,104 +20245,67 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-511-heating-pid-output"
+ "@id": "urn:ex/vav-540-discharge-air-flow"
},
{
- "@id": "urn:ex/vav-511-more-heat-requests"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-511-air-out"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-515-damper-out",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-515-duct-after-damper"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "@id": "urn:ex/vav-540-discharge-air-flow-setpoint"
+ },
{
- "@id": "urn:ex/vav-515-colder-supply-air-requests"
+ "@id": "urn:ex/vav-540-discharge-air-temp"
},
{
- "@id": "urn:ex/vav-515-cooling-pid-output"
+ "@id": "urn:ex/vav-540-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/vav-504-reheat-coil-water-in",
+ "@id": "urn:ex/vav-525-hot-water-out-connection",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-504-hot-water-in-connection"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-504-hot-water-in"
- }
]
},
{
- "@id": "urn:ex/zone-206-co2-concentration-setpoint",
+ "@id": "urn:ex/vav-510-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
- "http://data.ashrae.org/standard223#ofSubstance": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Substance-CO2"
- }
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "@id": "urn:ex/vav-510-reheat-coil-valve-in"
+ },
{
- "@id": "http://qudt.org/vocab/quantitykind/MoleFraction"
+ "@id": "urn:ex/vav-510-reheat-coil-valve-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PPM"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
}
- ]
- },
- {
- "@id": "urn:ex/vav-523-hot-water-in-connection",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-510-reheat-coil-valve-command"
+ },
+ {
+ "@id": "urn:ex/vav-510-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-540-air-in",
+ "@id": "urn:ex/room-118-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/connection-to-room-118"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -20202,181 +20315,131 @@
]
},
{
- "@id": "urn:ex/vav-526-reheat-coil-valve-out",
+ "@id": "urn:ex/vav-533-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-526-hot-water-out-connection"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "@id": "urn:ex/vav-533-reheat-coil-valve-in"
+ },
{
- "@id": "urn:ex/vav-526-hot-water-out"
+ "@id": "urn:ex/vav-533-reheat-coil-valve-out"
}
- ]
- },
- {
- "@id": "urn:ex/vav-532-damper",
- "@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-532-damper-in"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-532-damper-out"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-532-damper-command"
+ "@id": "urn:ex/vav-533-reheat-coil-valve-command"
},
{
- "@id": "urn:ex/vav-532-damper-position"
+ "@id": "urn:ex/vav-533-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-529-reheat-coil-water-out",
+ "@id": "urn:ex/vav-532-damper-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-529-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-532-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/vav-540-damper-actuator",
- "@type": [
- "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-540-damper"
- }
- ],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "@id": "urn:ex/vav-532-colder-supply-air-requests"
+ },
{
- "@id": "urn:ex/vav-540-damper-command"
+ "@id": "urn:ex/vav-532-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/vav-526",
+ "@id": "urn:ex/vav-518-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-526-air-in"
- },
- {
- "@id": "urn:ex/vav-526-air-out"
- },
- {
- "@id": "urn:ex/vav-526-hot-water-in"
- },
- {
- "@id": "urn:ex/vav-526-hot-water-out"
+ "@id": "urn:ex/vav-518-hot-water-in-connection"
}
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/vav-526-damper"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-526-reheat-coil"
- },
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-526-reheat-coil-valve"
+ "@id": "urn:ex/vav-518-hot-water-in"
}
]
},
{
- "@id": "urn:ex/vav-536-discharge-air-temp-sensor",
+ "@id": "urn:ex/zone-104-occupancy-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-536-air-out"
+ "@id": "urn:ex/room-104-hvac-domain"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-536-discharge-air-temp"
+ "@id": "urn:ex/zone-104-occupancy"
}
]
},
{
- "@id": "urn:ex/vav-511",
+ "@id": "urn:ex/vav-515-duct-after-damper",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-511-air-in"
- },
- {
- "@id": "urn:ex/vav-511-air-out"
- },
- {
- "@id": "urn:ex/vav-511-hot-water-in"
- },
- {
- "@id": "urn:ex/vav-511-hot-water-out"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/vav-511-damper"
- },
- {
- "@id": "urn:ex/vav-511-reheat-coil"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-511-reheat-coil-valve"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-530-damper-position",
+ "@id": "urn:ex/vav-526-discharge-air-temp",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
+ "http://data.ashrae.org/standard223#hasAspect": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
+ ],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-501-reheat-coil-valve-command",
+ "@id": "urn:ex/vav-527-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -20390,91 +20453,58 @@
]
},
{
- "@id": "urn:ex/vav-514-reheat-coil-air-out",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/connection-to-room-115"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-514-heating-pid-output"
- },
- {
- "@id": "urn:ex/vav-514-more-heat-requests"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-514-air-out"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-530-damper-command",
+ "@id": "urn:ex/vav-527-discharge-air-flow-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/zone-106-107-temp",
+ "@id": "urn:ex/vav-540-damper-command",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/zone-110-temp-sensor",
+ "@id": "urn:ex/zone-111-occupancy-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/room-110-hvac-domain"
+ "@id": "urn:ex/room-111-hvac-domain"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/zone-110-temp"
+ "@id": "urn:ex/zone-111-occupancy"
}
]
},
{
- "@id": "urn:ex/vav-515-air-in",
+ "@id": "urn:ex/vav-527-duct-after-damper",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/office-ahu-connection-to-vavs"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -20483,82 +20513,78 @@
]
},
{
- "@id": "urn:ex/zone-314-heating-setpoint",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
- {
- "@id": "http://qudt.org/vocab/unit/DEG_C"
- }
- ]
- },
- {
- "@id": "urn:ex/zone-118",
+ "@id": "urn:ex/vav-529-air-out",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-118-hvac-domain"
+ "@id": "urn:ex/connection-to-room-303-304-306"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/zone-118-cooling-setpoint"
- },
- {
- "@id": "urn:ex/zone-118-heating-setpoint"
+ "@id": "urn:ex/vav-529-discharge-air-flow"
},
{
- "@id": "urn:ex/zone-118-occupancy"
+ "@id": "urn:ex/vav-529-discharge-air-flow-setpoint"
},
{
- "@id": "urn:ex/zone-118-occupancy-override"
+ "@id": "urn:ex/vav-529-discharge-air-temp"
},
{
- "@id": "urn:ex/zone-118-temp"
- },
+ "@id": "urn:ex/vav-529-discharge-air-temp-setpoint"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-510-pipe-hot-water-return-before-valve",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-118-window-switch-on-off"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/zone-204-205-heating-setpoint",
+ "@id": "urn:ex/vav-525-hot-water-in-connection",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-103-window-switch-on-off",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/office-ahu-ra-fan-out",
+ "@id": "urn:ex/room-311-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-duct-after-ra-fan"
+ "@id": "urn:ex/connection-to-room-311"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -20568,10 +20594,14 @@
]
},
{
- "@id": "urn:ex/connection-to-room-303-304-306",
+ "@id": "urn:ex/vav-529-reheat-coil-air-in",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-529-duct-after-damper"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -20580,9 +20610,9 @@
]
},
{
- "@id": "urn:ex/vav-523-reheat-coil-valve-position",
+ "@id": "urn:ex/vav-532-reheat-coil-valve-command",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -20596,62 +20626,52 @@
]
},
{
- "@id": "urn:ex/vav-517-reheat-coil-valve-out",
+ "@id": "urn:ex/vav-504-damper",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-517-hot-water-out-connection"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:ex/vav-504-damper-in"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-504-damper-out"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-517-hot-water-out"
+ "@id": "urn:ex/vav-504-damper-command"
+ },
+ {
+ "@id": "urn:ex/vav-504-damper-position"
}
]
},
{
- "@id": "urn:ex/vav-532-discharge-air-flow-setpoint",
+ "@id": "urn:ex/vav-523-damper-command",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-528-hot-water-in-connection",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-529-reheat-coil-air-in",
+ "@id": "urn:ex/vav-524-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-529-duct-after-damper"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -20661,29 +20681,41 @@
]
},
{
- "@id": "urn:ex/room-212-out",
+ "@id": "urn:ex/vav-501-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/vav-501-reheat-coil-valve-in"
+ },
+ {
+ "@id": "urn:ex/vav-501-reheat-coil-valve-out"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-501-reheat-coil-valve-command"
+ },
+ {
+ "@id": "urn:ex/vav-501-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-515-reheat-coil-air-out",
+ "@id": "urn:ex/vav-524-reheat-coil-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-116-117"
+ "@id": "urn:ex/connection-to-room-210"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -20693,99 +20725,121 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-515-heating-pid-output"
+ "@id": "urn:ex/vav-524-heating-pid-output"
},
{
- "@id": "urn:ex/vav-515-more-heat-requests"
+ "@id": "urn:ex/vav-524-more-heat-requests"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-524-air-out"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-535-hot-water-in-connection",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-515-air-out"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/zone-307-308",
+ "@id": "urn:ex/office-ahu-htg-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/room-307-hvac-domain"
- },
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-308-hvac-domain"
+ "@id": "urn:ex/office-ahu-pipe-hot-water-return-before-valve"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-501-damper",
+ "@type": [
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/zone-307-308-cooling-setpoint"
- },
- {
- "@id": "urn:ex/zone-307-308-heating-setpoint"
- },
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/zone-307-308-occupancy"
+ "@id": "urn:ex/vav-501-damper-in"
},
{
- "@id": "urn:ex/zone-307-308-occupancy-override"
- },
+ "@id": "urn:ex/vav-501-damper-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/zone-307-308-temp"
+ "@id": "urn:ex/vav-501-damper-command"
},
{
- "@id": "urn:ex/zone-307-308-window-switch-on-off"
+ "@id": "urn:ex/vav-501-damper-position"
}
]
},
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override",
- "@type": [
- "http://data.ashrae.org/standard223#EnumerationKind"
- ]
- },
- {
- "@id": "urn:ex/vav-537-discharge-air-temp-setpoint",
+ "@id": "urn:ex/vav-529-discharge-air-flow-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/office-ahu-warmer-supply-air-requests",
+ "@id": "urn:ex/vav-517-duct-after-damper",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-504-reheat-coil-air-out",
+ "@id": "urn:ex/vav-529-damper-actuator",
+ "@type": [
+ "http://data.ashrae.org/standard223#Actuator"
+ ],
+ "http://data.ashrae.org/standard223#actuates": [
+ {
+ "@id": "urn:ex/vav-529-damper"
+ }
+ ],
+ "http://data.ashrae.org/standard223#commandedByProperty": [
+ {
+ "@id": "urn:ex/vav-529-damper-command"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-538-reheat-coil-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-105"
+ "@id": "urn:ex/connection-to-room-213"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -20795,23 +20849,27 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-504-heating-pid-output"
+ "@id": "urn:ex/vav-538-heating-pid-output"
},
{
- "@id": "urn:ex/vav-504-more-heat-requests"
+ "@id": "urn:ex/vav-538-more-heat-requests"
}
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-504-air-out"
+ "@id": "urn:ex/vav-538-air-out"
}
]
},
{
- "@id": "urn:ex/vav-514-hot-water-in-connection",
+ "@id": "urn:ex/vav-534-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-534-pipe-hot-water-return-before-valve"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -20820,62 +20878,55 @@
]
},
{
- "@id": "urn:ex/vav-533-discharge-air-flow",
+ "@id": "urn:ex/vav-533-hot-water-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:ex/vav-533-hot-water-in-connection"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-504-heating-pid-output",
+ "@id": "urn:ex/vav-520-air-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/connection-to-room-207"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/vav-533-discharge-air-temp-setpoint",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "urn:ex/vav-520-discharge-air-flow"
+ },
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-520-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-520-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-520-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/zone-312-heating-setpoint",
+ "@id": "urn:ex/zone-207-temp",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -20889,129 +20940,128 @@
]
},
{
- "@id": "urn:ex/vav-531-colder-supply-air-requests",
+ "@id": "urn:ex/zone-303-304-306-occupancy",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
]
},
{
- "@id": "urn:ex/vav-503-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/zone-115-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/room-115-hvac-domain"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:ex/zone-115-temp"
}
]
},
{
- "@id": "urn:ex/zone-211-occupancy-override",
+ "@id": "urn:ex/vav-521-hot-water-in-connection",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/zone-110-heating-setpoint",
+ "@id": "urn:ex/vav-515-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-515-hot-water-in-connection"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
- ]
- },
- {
- "@id": "urn:ex/vav-521-colder-supply-air-requests",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/vav-515-hot-water-in"
}
]
},
{
- "@id": "urn:ex/vav-516-damper",
+ "@id": "urn:ex/vav-523-cooling-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-516-damper-in"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-516-damper-out"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-516-damper-command"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-516-damper-position"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-516-discharge-air-flow-sensor",
+ "@id": "urn:ex/vav-505-air-in",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-516-air-in"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-516-discharge-air-flow"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-522-reheat-coil-valve-command",
+ "@id": "urn:ex/vav-503-damper",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-503-damper-in"
+ },
+ {
+ "@id": "urn:ex/vav-503-damper-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/vav-503-damper-command"
+ },
+ {
+ "@id": "urn:ex/vav-503-damper-position"
}
]
},
{
- "@id": "urn:ex/vav-530-hot-water-in",
+ "@id": "urn:ex/vav-511-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-530-hot-water-in-connection"
+ "@id": "urn:ex/vav-511-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -21021,82 +21071,69 @@
]
},
{
- "@id": "urn:ex/vav-528-hot-water-in",
+ "@id": "urn:ex/connection-to-room-307-308",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-528-hot-water-in-connection"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/zone-105-occupancy-sensor",
+ "@id": "urn:ex/zone-207-occupancy-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/room-105-hvac-domain"
+ "@id": "urn:ex/room-207-hvac-domain"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/zone-105-occupancy"
+ "@id": "urn:ex/zone-207-occupancy"
}
]
},
{
- "@id": "urn:ex/zone-302-co2-concentration",
+ "@id": "urn:ex/zone-302-window-switch-on-off",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#ofSubstance": [
- {
- "@id": "http://data.ashrae.org/standard223#Substance-CO2"
- }
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/MoleFraction"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/PPM"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/vav-520-discharge-air-flow-setpoint",
+ "@id": "urn:ex/",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
- }
+ "http://www.w3.org/2002/07/owl#Ontology"
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-512-colder-supply-air-requests",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-508-reheat-coil-air-in",
+ "@id": "urn:ex/room-101-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-508-duct-after-damper"
+ "@id": "urn:ex/connection-to-room-101"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -21106,10 +21143,14 @@
]
},
{
- "@id": "urn:ex/vav-534-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/vav-522-hot-water-in",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-522-hot-water-in-connection"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -21118,41 +21159,37 @@
]
},
{
- "@id": "urn:ex/vav-507-discharge-air-flow-setpoint",
+ "@id": "urn:ex/office-ahu-duct-after-moisture-eliminator",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/room-303-in",
+ "@id": "urn:ex/vav-530-hot-water-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-303-304-306"
+ "@id": "urn:ex/vav-530-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-524-reheat-coil-valve-command",
+ "@id": "urn:ex/vav-522-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -21166,44 +21203,28 @@
]
},
{
- "@id": "urn:ex/zone-201-heating-setpoint",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
- {
- "@id": "http://qudt.org/vocab/unit/DEG_C"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-530-discharge-air-flow",
+ "@id": "urn:ex/vav-509-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:ex/vav-509-air-in"
}
]
},
{
- "@id": "urn:ex/vav-521-more-heat-requests",
+ "@id": "urn:ex/vav-509-more-heat-requests",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
@@ -21214,379 +21235,396 @@
]
},
{
- "@id": "urn:ex/vav-531-heating-pid-output",
+ "@id": "urn:ex/vav-538-reheat-coil-air-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/vav-538-duct-after-damper"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-518-damper",
+ "@id": "urn:ex/vav-501-reheat-coil-valve-out",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-518-damper-in"
- },
- {
- "@id": "urn:ex/vav-518-damper-out"
+ "@id": "urn:ex/vav-501-hot-water-out-connection"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-518-damper-command"
- },
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-518-damper-position"
+ "@id": "urn:ex/vav-501-hot-water-out"
}
]
},
{
- "@id": "urn:ex/vav-504-reheat-coil-valve-out",
+ "@id": "urn:ex/zone-110",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/vav-504-hot-water-out-connection"
+ "@id": "urn:ex/room-110-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-504-hot-water-out"
+ "@id": "urn:ex/zone-110-cooling-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-110-heating-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-110-occupancy"
+ },
+ {
+ "@id": "urn:ex/zone-110-occupancy-override"
+ },
+ {
+ "@id": "urn:ex/zone-110-temp"
+ },
+ {
+ "@id": "urn:ex/zone-110-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/room-214",
+ "@id": "urn:ex/vav-519-more-heat-requests",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/room-214-hvac-domain"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-513-damper-actuator",
+ "@id": "urn:ex/room-113-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-513-damper"
+ "@id": "urn:ex/room-113-in"
+ },
+ {
+ "@id": "urn:ex/room-113-out"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:ex/vav-513-damper-command"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/room-110-out",
+ "@id": "urn:ex/vav-520-damper-command",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-537-damper-actuator",
+ "@id": "urn:ex/zone-313-occupancy-sensor",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
- ],
- "http://data.ashrae.org/standard223#actuates": [
- {
- "@id": "urn:ex/vav-537-damper"
- }
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-537-damper-command"
+ "@id": "urn:ex/room-313-hvac-domain"
}
- ]
- },
- {
- "@id": "urn:ex/zone-106-107-occupancy-override",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "urn:ex/zone-313-occupancy"
}
]
},
{
- "@id": "urn:ex/room-213-out",
+ "@id": "urn:ex/zone-204-205-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-510-reheat-coil",
+ "@id": "urn:ex/vav-513-hot-water-in",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-510-reheat-coil-air-in"
- },
- {
- "@id": "urn:ex/vav-510-reheat-coil-air-out"
- },
- {
- "@id": "urn:ex/vav-510-reheat-coil-water-in"
- },
- {
- "@id": "urn:ex/vav-510-reheat-coil-water-out"
+ "@id": "urn:ex/vav-513-hot-water-in-connection"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/zone-101-window-switch-on-off",
+ "@id": "urn:ex/vav-502-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "urn:ex/vav-502-pipe-hot-water-return-before-valve"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/office-ahu-clg-coil-air-out",
+ "@id": "urn:ex/vav-529-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-duct-after-clg-coil"
+ "@id": "urn:ex/vav-529-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-503-reheat-coil-valve-out",
+ "@id": "urn:ex/vav-518-reheat-coil-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-503-hot-water-out-connection"
+ "@id": "urn:ex/connection-to-room-202"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-518-heating-pid-output"
+ },
+ {
+ "@id": "urn:ex/vav-518-more-heat-requests"
}
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-503-hot-water-out"
+ "@id": "urn:ex/vav-518-air-out"
}
]
},
{
- "@id": "urn:ex/room-116-hvac-domain",
+ "@id": "urn:ex/vav-516-discharge-air-flow-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/room-116-in"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-116-out"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-514-reheat-coil",
+ "@id": "urn:ex/vav-522-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-514-reheat-coil-air-in"
- },
+ "@id": "urn:ex/vav-522-duct-after-damper"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-514-reheat-coil-air-out"
- },
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-514-reheat-coil-water-in"
+ "@id": "urn:ex/vav-522-colder-supply-air-requests"
},
{
- "@id": "urn:ex/vav-514-reheat-coil-water-out"
+ "@id": "urn:ex/vav-522-cooling-pid-output"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-314-occupancy",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
]
},
{
- "@id": "urn:ex/vav-521-heating-pid-output",
+ "@id": "urn:ex/room-111",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/room-111-hvac-domain"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-520-hot-water-in-connection",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-516-discharge-air-temp-setpoint",
+ "@id": "urn:ex/vav-519-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-532-reheat-coil-valve-out",
+ "@id": "urn:ex/office-ahu-htg-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-532-hot-water-out-connection"
- }
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/office-ahu-htg-coil-valve"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/vav-532-hot-water-out"
+ "@id": "urn:ex/office-ahu-htg-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/vav-534-discharge-air-flow-sensor",
+ "@id": "urn:ex/zone-314-occupancy-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-534-air-in"
+ "@id": "urn:ex/room-314-hvac-domain"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-534-discharge-air-flow"
+ "@id": "urn:ex/zone-314-occupancy"
}
]
},
{
- "@id": "urn:ex/vav-507-discharge-air-temp-setpoint",
+ "@id": "urn:ex/zone-109-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/room-109-hvac-domain"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/zone-109-temp"
}
]
},
{
- "@id": "urn:ex/vav-522-damper-actuator",
+ "@id": "urn:ex/vav-526-reheat-coil-air-in",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-522-damper"
+ "@id": "urn:ex/vav-526-duct-after-damper"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-522-damper-command"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-517-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-527-reheat-coil-valve-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-517-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-527-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -21596,219 +21634,226 @@
]
},
{
- "@id": "urn:ex/vav-529-damper-command",
+ "@id": "urn:ex/zone-211",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/room-211-hvac-domain"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
- ]
- },
- {
- "@id": "urn:ex/office-ahu-htg-coil-valve-command",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "urn:ex/zone-211-cooling-setpoint"
+ },
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/zone-211-heating-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-211-occupancy"
+ },
+ {
+ "@id": "urn:ex/zone-211-occupancy-override"
+ },
+ {
+ "@id": "urn:ex/zone-211-temp"
+ },
+ {
+ "@id": "urn:ex/zone-211-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-534",
+ "@id": "urn:ex/vav-501",
"@type": [
"http://data.ashrae.org/standard223#SingleDuctTerminal",
"http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-534-air-in"
+ "@id": "urn:ex/vav-501-air-in"
},
{
- "@id": "urn:ex/vav-534-air-out"
+ "@id": "urn:ex/vav-501-air-out"
},
{
- "@id": "urn:ex/vav-534-hot-water-in"
+ "@id": "urn:ex/vav-501-hot-water-in"
},
{
- "@id": "urn:ex/vav-534-hot-water-out"
+ "@id": "urn:ex/vav-501-hot-water-out"
}
],
"http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/vav-534-damper"
+ "@id": "urn:ex/vav-501-damper"
},
{
- "@id": "urn:ex/vav-534-reheat-coil"
+ "@id": "urn:ex/vav-501-reheat-coil"
},
{
- "@id": "urn:ex/vav-534-reheat-coil-valve"
+ "@id": "urn:ex/vav-501-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/vav-535-hot-water-out-connection",
+ "@id": "urn:ex/vav-533-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-533-air-in"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:ex/vav-533-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/vav-528-colder-supply-air-requests",
+ "@id": "urn:ex/zone-108-occupancy-override",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
]
},
{
- "@id": "urn:ex/office-ahu-sa-fan-start-cmd",
+ "@id": "urn:ex/vav-519-hot-water-out-connection",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-518-reheat-coil-valve-out",
+ "@id": "urn:ex/vav-537-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-518-hot-water-out-connection"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-518-hot-water-out"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-533-discharge-air-flow-setpoint",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
- {
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:ex/vav-537-air-in"
}
]
},
{
- "@id": "urn:ex/vav-530-air-out",
+ "@id": "urn:ex/vav-525-damper",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-303-304-306"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:ex/vav-525-damper-in"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-525-damper-out"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-530-discharge-air-flow"
- },
- {
- "@id": "urn:ex/vav-530-discharge-air-flow-setpoint"
- },
- {
- "@id": "urn:ex/vav-530-discharge-air-temp"
+ "@id": "urn:ex/vav-525-damper-command"
},
{
- "@id": "urn:ex/vav-530-discharge-air-temp-setpoint"
+ "@id": "urn:ex/vav-525-damper-position"
}
]
},
{
- "@id": "urn:ex/vav-519-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/connection-to-room-104",
"@type": [
"http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-524-discharge-air-temp-sensor",
+ "@id": "urn:ex/vav-512-discharge-air-temp-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-524-air-out"
+ "@id": "urn:ex/vav-512-air-out"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-524-discharge-air-temp"
+ "@id": "urn:ex/vav-512-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/vav-532-heating-pid-output",
+ "@id": "urn:ex/vav-517-reheat-coil-valve-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/vav-517-hot-water-out-connection"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-517-hot-water-out"
}
]
},
{
- "@id": "urn:ex/vav-521-hot-water-in-connection",
+ "@id": "urn:ex/office-ahu-sa-fan-start-status",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ {
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-511-reheat-coil-water-out",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-511-pipe-hot-water-return-before-valve"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -21817,272 +21862,310 @@
]
},
{
- "@id": "urn:ex/office-ahu-ra-flow-sensor",
+ "@id": "urn:ex/zone-215-occupancy",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ {
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-517-discharge-air-flow-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/office-ahu-ra-in"
+ "@id": "urn:ex/vav-517-air-in"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/office-ahu-ra-flow"
+ "@id": "urn:ex/vav-517-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/room-202-in",
+ "@id": "urn:ex/zone-213",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/connection-to-room-202"
+ "@id": "urn:ex/room-213-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/zone-213-cooling-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-213-heating-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-213-occupancy"
+ },
+ {
+ "@id": "urn:ex/zone-213-occupancy-override"
+ },
+ {
+ "@id": "urn:ex/zone-213-temp"
+ },
+ {
+ "@id": "urn:ex/zone-213-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/room-301",
+ "@id": "urn:ex/vav-505-cooling-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-301-hvac-domain"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-540-damper-out",
+ "@id": "urn:ex/vav-513-discharge-air-temp",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/vav-540-duct-after-damper"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-540-colder-supply-air-requests"
- },
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-515-more-heat-requests",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-540-cooling-pid-output"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/zone-118-temp-sensor",
+ "@id": "urn:ex/vav-507-discharge-air-flow-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-118-hvac-domain"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/zone-118-temp"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-540-reheat-coil",
+ "@id": "urn:ex/vav-539-hot-water-in",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-540-reheat-coil-air-in"
- },
- {
- "@id": "urn:ex/vav-540-reheat-coil-air-out"
- },
- {
- "@id": "urn:ex/vav-540-reheat-coil-water-in"
- },
- {
- "@id": "urn:ex/vav-540-reheat-coil-water-out"
+ "@id": "urn:ex/vav-539-hot-water-in-connection"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-522-reheat-coil-valve-position",
+ "@id": "urn:ex/vav-516-reheat-coil-valve-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-516-hot-water-out-connection"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/vav-516-hot-water-out"
}
]
},
{
- "@id": "urn:ex/vav-517-air-in",
+ "@id": "urn:ex/vav-529-reheat-coil-air-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/connection-to-room-303-304-306"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/vav-528-reheat-coil-valve-command",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-529-heating-pid-output"
+ },
+ {
+ "@id": "urn:ex/vav-529-more-heat-requests"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/vav-529-air-out"
}
]
},
{
- "@id": "urn:ex/room-311-in",
+ "@id": "urn:ex/vav-514-reheat-coil-valve-command",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/connection-to-room-311"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-511-discharge-air-temp",
+ "@id": "urn:ex/vav-506-damper-command",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-508-cooling-pid-output",
+ "@id": "urn:ex/vav-522-discharge-air-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-529-colder-supply-air-requests",
+ "@id": "urn:ex/zone-201-window-switch-on-off",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/vav-537-discharge-air-temp-sensor",
+ "@id": "urn:ex/vav-536-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-537-air-out"
+ "@id": "urn:ex/vav-536-pipe-hot-water-return-before-valve"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-537-discharge-air-temp"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-529-air-in",
+ "@id": "urn:ex/zone-212-window-switch-on-off",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/office-ahu-connection-to-vavs"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/vav-534-hot-water-out-connection",
+ "@id": "urn:ex/vav-531-damper",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-531-damper-in"
+ },
+ {
+ "@id": "urn:ex/vav-531-damper-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-531-damper-command"
+ },
+ {
+ "@id": "urn:ex/vav-531-damper-position"
}
]
},
{
- "@id": "urn:ex/vav-515-discharge-air-temp",
+ "@id": "urn:ex/vav-532-discharge-air-flow",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -22093,91 +22176,82 @@
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-523-discharge-air-temp-setpoint",
+ "@id": "urn:ex/room-201-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-513-reheat-coil-water-in",
+ "@id": "urn:ex/vav-515-reheat-coil-valve-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-513-hot-water-in-connection"
+ "@id": "urn:ex/vav-515-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-513-hot-water-in"
- }
]
},
{
- "@id": "urn:ex/vav-527-discharge-air-temp",
+ "@id": "urn:ex/vav-506-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ "@id": "urn:ex/vav-506-hot-water-in-connection"
}
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-506-hot-water-in"
}
]
},
{
- "@id": "urn:ex/room-117-out",
+ "@id": "urn:ex/vav-512-pipe-hot-water-return-before-valve",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/office-ahu-connection-from-rooms"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/connection-to-room-105",
+ "@id": "urn:ex/vav-507-duct-after-damper",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Duct"
@@ -22189,96 +22263,68 @@
]
},
{
- "@id": "urn:ex/vav-509-damper-command",
+ "@id": "urn:ex/vav-501-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/vav-501-damper"
}
- ]
- },
- {
- "@id": "urn:ex/office-ahu-connection-from-rooms",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-501-damper-command"
}
]
},
{
- "@id": "urn:ex/office-ahu-ra-damper-in",
+ "@id": "urn:ex/zone-103-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/office-ahu-duct-after-ra-fan"
+ "@id": "urn:ex/room-103-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/zone-103-temp"
}
]
},
{
- "@id": "urn:ex/vav-529-reheat-coil-valve",
+ "@id": "urn:ex/vav-537-damper",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-529-reheat-coil-valve-in"
+ "@id": "urn:ex/vav-537-damper-in"
},
{
- "@id": "urn:ex/vav-529-reheat-coil-valve-out"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "urn:ex/vav-537-damper-out"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-529-reheat-coil-valve-command"
+ "@id": "urn:ex/vav-537-damper-command"
},
{
- "@id": "urn:ex/vav-529-reheat-coil-valve-position"
- }
- ]
- },
- {
- "@id": "urn:ex/zone-108-occupancy",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "urn:ex/vav-537-damper-position"
}
]
},
{
- "@id": "urn:ex/vav-538-reheat-coil-air-in",
+ "@id": "urn:ex/vav-539-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-538-duct-after-damper"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -22288,95 +22334,114 @@
]
},
{
- "@id": "urn:ex/vav-538-reheat-coil-water-out",
+ "@id": "urn:ex/vav-531-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-538-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-531-air-in"
}
]
},
{
- "@id": "urn:ex/vav-523-reheat-coil-valve-actuator",
+ "@id": "urn:ex/office-ahu-sa-fan-in",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-523-reheat-coil-valve"
+ "@id": "urn:ex/office-ahu-duct-after-clg-coil"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-523-reheat-coil-valve-command"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/office-ahu-sa-flow"
}
]
},
{
- "@id": "urn:ex/vav-519-discharge-air-temp-setpoint",
+ "@id": "urn:ex/zone-101-co2-concentration-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
+ "http://data.ashrae.org/standard223#ofSubstance": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Substance-CO2"
+ }
+ ],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/MoleFraction"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PPM"
}
]
},
{
- "@id": "urn:ex/vav-506-reheat-coil-water-in",
+ "@id": "urn:ex/zone-201",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/vav-506-hot-water-in-connection"
+ "@id": "urn:ex/room-201-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-506-hot-water-in"
+ "@id": "urn:ex/zone-201-cooling-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-201-heating-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-201-occupancy"
+ },
+ {
+ "@id": "urn:ex/zone-201-occupancy-override"
+ },
+ {
+ "@id": "urn:ex/zone-201-temp"
+ },
+ {
+ "@id": "urn:ex/zone-201-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-506-discharge-air-flow-setpoint",
+ "@id": "urn:ex/room-113-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
- ]
- },
- {
- "@id": "urn:ex/vav-510-duct-after-damper",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -22385,76 +22450,108 @@
]
},
{
- "@id": "urn:ex/vav-535-damper-position",
+ "@id": "urn:ex/vav-536-heating-pid-output",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/office-ahu-sa-fan",
+ "@id": "urn:ex/vav-540-more-heat-requests",
"@type": [
- "http://data.ashrae.org/standard223#Fan",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#FanWithVFD"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/office-ahu-sa-fan-in"
- },
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-311",
+ "@type": [
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
+ ],
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/office-ahu-sa-fan-out"
+ "@id": "urn:ex/room-311-hvac-domain"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasDomain": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/office-ahu-sa-fan-power"
+ "@id": "urn:ex/zone-311-cooling-setpoint"
},
{
- "@id": "urn:ex/office-ahu-sa-fan-speed-cmd"
+ "@id": "urn:ex/zone-311-heating-setpoint"
},
{
- "@id": "urn:ex/office-ahu-sa-fan-speed-status"
+ "@id": "urn:ex/zone-311-occupancy"
},
{
- "@id": "urn:ex/office-ahu-sa-fan-start-cmd"
+ "@id": "urn:ex/zone-311-occupancy-override"
},
{
- "@id": "urn:ex/office-ahu-sa-fan-start-status"
- }
- ],
- "http://data.ashrae.org/standard223#hasRole": [
+ "@id": "urn:ex/zone-311-temp"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Role-Supply"
+ "@id": "urn:ex/zone-311-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-512-hot-water-in",
+ "@id": "urn:ex/zone-115",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/vav-512-hot-water-in-connection"
+ "@id": "urn:ex/room-115-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/zone-115-cooling-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-115-heating-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-115-occupancy"
+ },
+ {
+ "@id": "urn:ex/zone-115-occupancy-override"
+ },
+ {
+ "@id": "urn:ex/zone-115-temp"
+ },
+ {
+ "@id": "urn:ex/zone-115-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-537-damper-in",
+ "@id": "urn:ex/vav-530-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -22467,79 +22564,60 @@
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-537-air-in"
- }
]
},
{
- "@id": "urn:ex/vav-517-heating-pid-output",
+ "@id": "urn:ex/vav-533-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/vav-533-reheat-coil-valve"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "urn:ex/vav-533-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/zone-101-co2-sensor",
+ "@id": "urn:ex/connection-to-room-211",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:ex/room-101-hvac-domain"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-101-co2-concentration"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-530-reheat-coil",
+ "@id": "urn:ex/vav-537-air-in",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-530-reheat-coil-air-in"
- },
- {
- "@id": "urn:ex/vav-530-reheat-coil-air-out"
- },
- {
- "@id": "urn:ex/vav-530-reheat-coil-water-in"
- },
- {
- "@id": "urn:ex/vav-530-reheat-coil-water-out"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-521-reheat-coil-air-out",
+ "@id": "urn:ex/vav-514-reheat-coil-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-204-205"
+ "@id": "urn:ex/connection-to-room-115"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -22549,279 +22627,291 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-521-heating-pid-output"
+ "@id": "urn:ex/vav-514-heating-pid-output"
},
{
- "@id": "urn:ex/vav-521-more-heat-requests"
+ "@id": "urn:ex/vav-514-more-heat-requests"
}
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-521-air-out"
+ "@id": "urn:ex/vav-514-air-out"
}
]
},
{
- "@id": "urn:ex/room-102-out",
+ "@id": "urn:ex/vav-517-damper-command",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/connection-to-room-301",
+ "@id": "urn:ex/zone-101-occupancy-override",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
]
},
{
- "@id": "urn:ex/vav-506",
+ "@id": "urn:ex/vav-522",
"@type": [
"http://data.ashrae.org/standard223#SingleDuctTerminal",
"http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-506-air-in"
+ "@id": "urn:ex/vav-522-air-in"
},
{
- "@id": "urn:ex/vav-506-air-out"
+ "@id": "urn:ex/vav-522-air-out"
},
{
- "@id": "urn:ex/vav-506-hot-water-in"
+ "@id": "urn:ex/vav-522-hot-water-in"
},
{
- "@id": "urn:ex/vav-506-hot-water-out"
+ "@id": "urn:ex/vav-522-hot-water-out"
}
],
"http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/vav-506-damper"
+ "@id": "urn:ex/vav-522-damper"
},
{
- "@id": "urn:ex/vav-506-reheat-coil"
+ "@id": "urn:ex/vav-522-reheat-coil"
},
{
- "@id": "urn:ex/vav-506-reheat-coil-valve"
+ "@id": "urn:ex/vav-522-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/vav-508-air-in",
+ "@id": "urn:ex/office-ahu-oa-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/office-ahu-oa-damper-in"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/office-ahu-oa-flow"
}
]
},
{
- "@id": "urn:ex/vav-516-heating-pid-output",
+ "@id": "urn:ex/room-107-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-534-reheat-coil-water-out",
+ "@id": "urn:ex/vav-536-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-534-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-536-air-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-536-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/vav-512-reheat-coil-valve",
+ "@id": "urn:ex/vav-520-colder-supply-air-requests",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-512-reheat-coil-valve-in"
- },
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-512-reheat-coil-valve-out"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/office-ahu-htg-coil-valve-command",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-512-reheat-coil-valve-command"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-512-reheat-coil-valve-position"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-506-discharge-air-temp",
+ "@id": "urn:ex/vav-526-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-526-air-in"
}
]
},
{
- "@id": "urn:ex/vav-502-discharge-air-temp-sensor",
+ "@id": "urn:ex/vav-539-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-502-air-out"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-502-discharge-air-temp"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-502-air-in",
+ "@id": "urn:ex/vav-527-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-527-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-527-colder-supply-air-requests"
+ },
+ {
+ "@id": "urn:ex/vav-527-cooling-pid-output"
+ }
]
},
{
- "@id": "urn:ex/vav-508-discharge-air-temp",
+ "@id": "urn:ex/vav-511-damper",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "@id": "urn:ex/vav-511-damper-in"
+ },
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-511-damper-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-511-damper-command"
+ },
+ {
+ "@id": "urn:ex/vav-511-damper-position"
}
]
},
{
- "@id": "urn:ex/vav-520-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-516-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-520-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/office-ahu-ra-fan-in",
+ "@id": "urn:ex/vav-527-reheat-coil-water-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/vav-527-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/office-ahu-ra-in"
+ "@id": "urn:ex/vav-527-hot-water-in"
}
]
},
{
- "@id": "urn:ex/connection-to-room-104",
+ "@id": "urn:ex/vav-535-discharge-air-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-532-duct-after-damper",
+ "@id": "urn:ex/vav-506-duct-after-damper",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Duct"
@@ -22833,137 +22923,127 @@
]
},
{
- "@id": "urn:ex/vav-514-hot-water-out",
+ "@id": "urn:ex/vav-534-reheat-coil-valve-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-514-hot-water-out-connection"
+ "@id": "urn:ex/vav-534-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-534-hot-water-out"
+ }
]
},
{
- "@id": "urn:ex/vav-505-damper-out",
+ "@id": "urn:ex/vav-540-reheat-coil-valve-position",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-505-duct-after-damper"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-505-colder-supply-air-requests"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-505-cooling-pid-output"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-529-more-heat-requests",
+ "@id": "urn:ex/room-108-in",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/connection-to-room-108"
}
- ]
- },
- {
- "@id": "urn:ex/zone-103-window-switch-on-off",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/room-115",
+ "@id": "urn:ex/vav-524-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-115-hvac-domain"
+ "@id": "urn:ex/vav-524-hot-water-in-connection"
}
- ]
- },
- {
- "@id": "urn:ex/office-ahu-ra-damper-out",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/office-ahu-duct-after-oa-ra-damper"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-524-hot-water-in"
}
]
},
{
- "@id": "urn:ex/vav-534-reheat-coil-valve-position",
+ "@id": "urn:ex/vav-515-discharge-air-flow",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
+ "http://data.ashrae.org/standard223#hasAspect": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
+ ],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/zone-113-occupancy-override",
+ "@id": "urn:ex/vav-509-damper",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "urn:ex/vav-509-damper-in"
+ },
+ {
+ "@id": "urn:ex/vav-509-damper-out"
}
- ]
- },
- {
- "@id": "urn:ex/vav-520-duct-after-damper",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-509-damper-command"
+ },
+ {
+ "@id": "urn:ex/vav-509-damper-position"
}
]
},
{
- "@id": "urn:ex/vav-526-reheat-coil-valve-position",
+ "@id": "urn:ex/vav-507-reheat-coil-valve-command",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -22977,146 +23057,131 @@
]
},
{
- "@id": "urn:ex/zone-212-cooling-setpoint",
+ "@id": "urn:ex/vav-540-discharge-air-flow-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-522-discharge-air-flow-sensor",
+ "@id": "urn:ex/vav-518-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/vav-522-air-in"
+ "@id": "urn:ex/vav-518-reheat-coil-valve"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/vav-522-discharge-air-flow"
+ "@id": "urn:ex/vav-518-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/vav-518-reheat-coil",
+ "@id": "urn:ex/room-117-out",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-518-reheat-coil-air-in"
- },
- {
- "@id": "urn:ex/vav-518-reheat-coil-air-out"
- },
- {
- "@id": "urn:ex/vav-518-reheat-coil-water-in"
- },
- {
- "@id": "urn:ex/vav-518-reheat-coil-water-out"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-518-more-heat-requests",
+ "@id": "urn:ex/vav-535-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
- ]
- },
- {
- "@id": "urn:ex/vav-524-pipe-hot-water-return-before-valve",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/vav-530-duct-after-damper",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-535-air-in"
}
]
},
{
- "@id": "urn:ex/vav-539-damper-position",
+ "@id": "urn:ex/vav-529-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-529-pipe-hot-water-return-before-valve"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-520-hot-water-out-connection",
+ "@id": "urn:ex/vav-506-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-506-air-in"
}
]
},
{
- "@id": "urn:ex/zone-113-occupancy-sensor",
+ "@id": "urn:ex/room-104-out",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-113-hvac-domain"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-113-occupancy"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-512-reheat-coil-valve-position",
+ "@id": "urn:ex/vav-539-damper-command",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -23130,45 +23195,50 @@
]
},
{
- "@id": "urn:ex/vav-533-hot-water-out",
+ "@id": "urn:ex/zone-301",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/vav-533-hot-water-out-connection"
+ "@id": "urn:ex/room-301-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
- ]
- },
- {
- "@id": "urn:ex/room-210-in",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/connection-to-room-210"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:ex/zone-301-cooling-setpoint"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/zone-301-heating-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-301-occupancy"
+ },
+ {
+ "@id": "urn:ex/zone-301-occupancy-override"
+ },
+ {
+ "@id": "urn:ex/zone-301-temp"
+ },
+ {
+ "@id": "urn:ex/zone-301-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-538-hot-water-out",
+ "@id": "urn:ex/vav-513-reheat-coil-water-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-538-hot-water-out-connection"
+ "@id": "urn:ex/vav-513-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -23178,303 +23248,319 @@
]
},
{
- "@id": "urn:ex/vav-540-cooling-pid-output",
+ "@id": "urn:ex/vav-505-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/vav-505-air-in"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "urn:ex/vav-505-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/room-104-out",
+ "@id": "urn:ex/room-207-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/room-207-in"
+ },
+ {
+ "@id": "urn:ex/room-207-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-525-discharge-air-temp",
+ "@id": "urn:ex/vav-536-reheat-coil-air-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ "@id": "urn:ex/connection-to-room-313"
}
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-517-discharge-air-temp-setpoint",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "@id": "urn:ex/vav-536-heating-pid-output"
+ },
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-536-more-heat-requests"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-536-air-out"
}
]
},
{
- "@id": "urn:ex/vav-516-colder-supply-air-requests",
+ "@id": "urn:ex/zone-302-occupancy-override",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
]
},
{
- "@id": "urn:ex/vav-513-hot-water-out-connection",
+ "@id": "urn:ex/room-305-out",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-527-discharge-air-flow-sensor",
+ "@id": "urn:ex/vav-505-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-505-reheat-coil-valve-in"
+ },
+ {
+ "@id": "urn:ex/vav-505-reheat-coil-valve-out"
+ }
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-527-air-in"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-527-discharge-air-flow"
+ "@id": "urn:ex/vav-505-reheat-coil-valve-command"
+ },
+ {
+ "@id": "urn:ex/vav-505-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/room-312-out",
+ "@id": "urn:ex/zone-115-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-511-more-heat-requests",
+ "@id": "urn:ex/vav-533-discharge-air-flow-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-509-hot-water-out",
+ "@id": "urn:ex/vav-540-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-509-hot-water-out-connection"
+ "@id": "urn:ex/vav-540-air-in"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-540-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/connection-to-room-111",
+ "@id": "urn:ex/vav-538-colder-supply-air-requests",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/room-302-hvac-domain",
+ "@id": "urn:ex/vav-506-more-heat-requests",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/room-302-in"
- },
- {
- "@id": "urn:ex/room-302-out"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-501-discharge-air-temp-setpoint",
+ "@id": "urn:ex/vav-503-cooling-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-522-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-521-discharge-air-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-522-pipe-hot-water-return-before-valve"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/office-ahu-sa-temp",
+ "@id": "urn:ex/zone-101-co2-concentration",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#ofSubstance": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Supply"
+ "@id": "http://data.ashrae.org/standard223#Substance-CO2"
}
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/MoleFraction"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PPM"
}
]
},
{
- "@id": "urn:ex/zone-204-205-occupancy",
+ "@id": "urn:ex/vav-508-discharge-air-flow-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-514-discharge-air-flow-sensor",
+ "@id": "urn:ex/office-ahu-ra-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-514-air-in"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-514-discharge-air-flow"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-507-hot-water-in-connection",
+ "@id": "urn:ex/vav-537-reheat-coil-valve-command",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/zone-207-temp-sensor",
+ "@id": "urn:ex/zone-312-occupancy-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/room-207-hvac-domain"
+ "@id": "urn:ex/room-312-hvac-domain"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/zone-207-temp"
+ "@id": "urn:ex/zone-312-occupancy"
}
]
},
{
- "@id": "urn:ex/room-101-in",
+ "@id": "urn:ex/vav-513-reheat-coil-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-101"
+ "@id": "urn:ex/vav-513-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -23484,91 +23570,74 @@
]
},
{
- "@id": "urn:ex/vav-533-more-heat-requests",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
- }
- ]
- },
- {
- "@id": "urn:ex/connection-to-room-313",
+ "@id": "urn:ex/vav-511-hot-water-out-connection",
"@type": [
"http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-538-reheat-coil-water-in",
+ "@id": "urn:ex/vav-528-discharge-air-flow-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-538-hot-water-in-connection"
- }
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-538-hot-water-in"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-528-reheat-coil-valve-out",
+ "@id": "urn:ex/zone-206-window-switch-on-off",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-528-hot-water-out-connection"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-539-damper-actuator",
+ "@type": [
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-539-damper"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/vav-528-hot-water-out"
+ "@id": "urn:ex/vav-539-damper-command"
}
]
},
{
- "@id": "urn:ex/room-117-hvac-domain",
+ "@id": "urn:ex/vav-516-hot-water-out-connection",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/room-117-in"
- },
- {
- "@id": "urn:ex/room-117-out"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-516-discharge-air-flow",
+ "@id": "urn:ex/vav-538-discharge-air-flow",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -23589,7 +23658,7 @@
]
},
{
- "@id": "urn:ex/vav-529-discharge-air-flow-setpoint",
+ "@id": "urn:ex/vav-517-discharge-air-flow-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -23605,111 +23674,115 @@
]
},
{
- "@id": "urn:ex/vav-502-damper-in",
+ "@id": "urn:ex/vav-530-discharge-air-flow",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-502-air-in"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/office-ahu-oa-damper-in",
+ "@id": "urn:ex/vav-510-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/office-ahu-duct-after-moisture-eliminator"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/office-ahu-oa-flow"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/office-ahu-oa-temp"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-538-reheat-coil-valve-out",
+ "@id": "urn:ex/vav-539-reheat-coil-water-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-538-hot-water-out-connection"
+ "@id": "urn:ex/vav-539-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-528-hot-water-in-connection",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-538-hot-water-out"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-519-air-in",
+ "@id": "urn:ex/vav-535-more-heat-requests",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-313-occupancy",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
]
},
{
- "@id": "urn:ex/vav-507-reheat-coil-valve-position",
+ "@id": "urn:ex/office-ahu-moisture-eliminator",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#AirFilter",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Filter"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "urn:ex/office-ahu-moisture-eliminator-in"
+ },
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/office-ahu-moisture-eliminator-out"
}
]
},
{
- "@id": "urn:ex/vav-533-reheat-coil-valve-out",
+ "@id": "urn:ex/vav-516-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-533-hot-water-out-connection"
+ "@id": "urn:ex/vav-516-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -23719,126 +23792,135 @@
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-533-hot-water-out"
+ "@id": "urn:ex/vav-516-hot-water-in"
}
]
},
{
- "@id": "urn:ex/vav-501-hot-water-out-connection",
+ "@id": "urn:ex/office-ahu-htg-coil-valve-out",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/office-ahu-hot-water-out-connection"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/office-ahu-hot-water-out"
+ }
]
},
{
- "@id": "urn:ex/vav-536-discharge-air-temp-setpoint",
+ "@id": "urn:ex/vav-509-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-509-reheat-coil-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-509-reheat-coil-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-509-reheat-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-509-reheat-coil-water-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/vav-530-discharge-air-temp-setpoint",
+ "@id": "urn:ex/vav-534-damper-command",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/office-ahu-oa-damper-actuator",
+ "@id": "urn:ex/vav-504-hot-water-out-connection",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
- ],
- "http://data.ashrae.org/standard223#actuates": [
- {
- "@id": "urn:ex/office-ahu-oa-damper"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/office-ahu-oa-damper-command"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-534-damper-position",
+ "@id": "urn:ex/zone-214-cooling-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-513-heating-pid-output",
+ "@id": "urn:ex/vav-526-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/vav-526-air-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "urn:ex/vav-526-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/zone-314-occupancy",
+ "@id": "urn:ex/office-ahu-sa-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
- ]
- },
- {
- "@id": "urn:ex/room-210",
- "@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/room-210-hvac-domain"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-512-reheat-coil-valve-command",
+ "@id": "urn:ex/vav-522-reheat-coil-valve-command",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -23854,68 +23936,69 @@
]
},
{
- "@id": "urn:ex/vav-540-hot-water-out-connection",
+ "@id": "urn:ex/vav-531-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-531-reheat-coil-valve"
}
- ]
- },
- {
- "@id": "urn:ex/vav-501-hot-water-in-connection",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-531-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/zone-202-heating-setpoint",
+ "@id": "urn:ex/vav-517-air-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/connection-to-room-203"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-517-discharge-air-flow"
+ },
+ {
+ "@id": "urn:ex/vav-517-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-517-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-517-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/vav-522-discharge-air-temp",
+ "@id": "urn:ex/vav-534-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-534-air-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-534-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/zone-103-cooling-setpoint",
+ "@id": "urn:ex/zone-309-310-cooling-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -23931,126 +24014,130 @@
]
},
{
- "@id": "urn:ex/vav-540-reheat-coil-valve-actuator",
+ "@id": "urn:ex/room-117",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
- ],
- "http://data.ashrae.org/standard223#actuates": [
- {
- "@id": "urn:ex/vav-540-reheat-coil-valve"
- }
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "urn:ex/vav-540-reheat-coil-valve-command"
+ "@id": "urn:ex/room-117-hvac-domain"
}
]
},
{
- "@id": "urn:ex/vav-515-hot-water-in",
+ "@id": "urn:ex/vav-529-reheat-coil-valve-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-515-hot-water-in-connection"
+ "@id": "urn:ex/vav-529-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
- ]
- },
- {
- "@id": "urn:ex/vav-516-pipe-hot-water-return-before-valve",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-529-hot-water-out"
}
]
},
{
- "@id": "urn:ex/room-207",
+ "@id": "urn:ex/vav-530-colder-supply-air-requests",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/room-207-hvac-domain"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-532-damper-actuator",
+ "@id": "urn:ex/zone-207-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-532-damper"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-532-damper-command"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-515-discharge-air-temp-setpoint",
+ "@id": "urn:ex/vav-520-discharge-air-flow-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-520-hot-water-out",
+ "@id": "urn:ex/zone-210",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/vav-520-hot-water-out-connection"
+ "@id": "urn:ex/room-210-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/zone-210-cooling-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-210-heating-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-210-occupancy"
+ },
+ {
+ "@id": "urn:ex/zone-210-occupancy-override"
+ },
+ {
+ "@id": "urn:ex/zone-210-temp"
+ },
+ {
+ "@id": "urn:ex/zone-210-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-520-hot-water-in",
+ "@id": "urn:ex/room-314",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-520-hot-water-in-connection"
- }
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/room-314-hvac-domain"
}
]
},
{
- "@id": "urn:ex/vav-526-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/vav-504-hot-water-in-connection",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Pipe"
@@ -24062,40 +24149,29 @@
]
},
{
- "@id": "urn:ex/vav-521-discharge-air-temp-setpoint",
+ "@id": "urn:ex/vav-535-damper-command",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
- }
- ]
- },
- {
- "@id": "urn:ex/zone-204-205-occupancy-override",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-518-damper-out",
+ "@id": "urn:ex/office-ahu-oa-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-518-duct-after-damper"
+ "@id": "urn:ex/office-ahu-duct-after-moisture-eliminator"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -24105,231 +24181,214 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-518-colder-supply-air-requests"
+ "@id": "urn:ex/office-ahu-oa-flow"
},
{
- "@id": "urn:ex/vav-518-cooling-pid-output"
+ "@id": "urn:ex/office-ahu-oa-temp"
}
]
},
{
- "@id": "urn:ex/vav-527-reheat-coil-air-out",
+ "@id": "urn:ex/room-304-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-301"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-527-heating-pid-output"
+ "@id": "urn:ex/room-304-in"
},
{
- "@id": "urn:ex/vav-527-more-heat-requests"
+ "@id": "urn:ex/room-304-out"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:ex/vav-527-air-out"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-524-reheat-coil-valve-actuator",
+ "@id": "urn:ex/vav-522-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-524-reheat-coil-valve"
+ "@id": "urn:ex/vav-522-pipe-hot-water-return-before-valve"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-524-reheat-coil-valve-command"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-515-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/room-302",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/room-302-hvac-domain"
}
]
},
{
- "@id": "urn:ex/vav-524-cooling-pid-output",
+ "@id": "urn:ex/room-106",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
- }
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "urn:ex/room-106-hvac-domain"
}
]
},
{
- "@id": "urn:ex/vav-539-damper",
+ "@id": "urn:ex/vav-514-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-539-damper-in"
+ "@id": "urn:ex/vav-514-reheat-coil-air-in"
},
{
- "@id": "urn:ex/vav-539-damper-out"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "@id": "urn:ex/vav-514-reheat-coil-air-out"
+ },
{
- "@id": "urn:ex/vav-539-damper-command"
+ "@id": "urn:ex/vav-514-reheat-coil-water-in"
},
{
- "@id": "urn:ex/vav-539-damper-position"
+ "@id": "urn:ex/vav-514-reheat-coil-water-out"
}
- ]
- },
- {
- "@id": "urn:ex/zone-311-occupancy-override",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/vav-506-hot-water-out",
+ "@id": "urn:ex/room-202-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-506-hot-water-out-connection"
+ "@id": "urn:ex/room-202-in"
+ },
+ {
+ "@id": "urn:ex/room-202-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-508-damper-actuator",
+ "@id": "urn:ex/zone-202-occupancy-sensor",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-508-damper"
+ "@id": "urn:ex/room-202-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-508-damper-command"
+ "@id": "urn:ex/zone-202-occupancy"
}
]
},
{
- "@id": "urn:ex/vav-533-colder-supply-air-requests",
+ "@id": "urn:ex/vav-508-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/vav-508-reheat-coil-valve-in"
+ },
+ {
+ "@id": "urn:ex/vav-508-reheat-coil-valve-out"
}
- ]
- },
- {
- "@id": "urn:ex/vav-533-reheat-coil-valve-position",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/vav-508-reheat-coil-valve-command"
+ },
+ {
+ "@id": "urn:ex/vav-508-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/room-118-in",
+ "@id": "urn:ex/vav-521-damper",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-118"
+ "@id": "urn:ex/vav-521-damper-in"
+ },
+ {
+ "@id": "urn:ex/vav-521-damper-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-521-damper-command"
+ },
+ {
+ "@id": "urn:ex/vav-521-damper-position"
}
]
},
{
- "@id": "urn:ex/vav-526-discharge-air-flow-sensor",
+ "@id": "urn:ex/room-307-in",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-526-air-in"
+ "@id": "urn:ex/connection-to-room-307-308"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-526-discharge-air-flow"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-528-hot-water-out",
+ "@id": "urn:ex/vav-524-duct-after-damper",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-528-hot-water-out-connection"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/zone-104-temp",
+ "@id": "urn:ex/zone-102-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -24343,43 +24402,55 @@
]
},
{
- "@id": "urn:ex/connection-to-room-101",
+ "@id": "urn:ex/vav-537-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-516-damper-out",
+ "@id": "urn:ex/vav-502-reheat-coil-air-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-516-duct-after-damper"
+ "@id": "urn:ex/vav-502-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-213-heating-setpoint",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-516-colder-supply-air-requests"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-516-cooling-pid-output"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-513-cooling-pid-output",
+ "@id": "urn:ex/vav-512-heating-pid-output",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -24395,7 +24466,7 @@
]
},
{
- "@id": "urn:ex/zone-108-cooling-setpoint",
+ "@id": "urn:ex/vav-524-discharge-air-temp-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -24411,61 +24482,63 @@
]
},
{
- "@id": "urn:ex/vav-525-damper-actuator",
+ "@id": "urn:ex/vav-538-reheat-coil-valve-position",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-525-damper"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-525-damper-command"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/zone-313-cooling-setpoint",
+ "@id": "urn:ex/vav-526-reheat-coil-valve-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-526-hot-water-out-connection"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
- ]
- },
- {
- "@id": "urn:ex/vav-516-more-heat-requests",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/vav-526-hot-water-out"
}
]
},
{
- "@id": "urn:ex/vav-512-colder-supply-air-requests",
+ "@id": "urn:ex/room-101-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/room-101-in"
+ },
+ {
+ "@id": "urn:ex/room-101-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasDomain": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-531-hot-water-out-connection",
+ "@id": "urn:ex/vav-510-hot-water-out-connection",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Pipe"
@@ -24477,82 +24550,106 @@
]
},
{
- "@id": "urn:ex/zone-314-cooling-setpoint",
+ "@id": "urn:ex/vav-516-cooling-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-520-discharge-air-flow",
+ "@id": "urn:ex/vav-526-hot-water-out-connection",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-518",
+ "@type": [
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:ex/vav-518-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-518-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-518-hot-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-518-hot-water-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:ex/vav-518-damper"
+ },
+ {
+ "@id": "urn:ex/vav-518-reheat-coil"
+ },
+ {
+ "@id": "urn:ex/vav-518-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/zone-112-114-temp-sensor",
+ "@id": "urn:ex/vav-534-hot-water-in-connection",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:ex/room-112-hvac-domain"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-112-114-temp"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-538-heating-pid-output",
+ "@id": "urn:ex/vav-520-discharge-air-flow",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
+ "http://data.ashrae.org/standard223#hasAspect": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
+ ],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-523-reheat-coil-valve-out",
+ "@id": "urn:ex/vav-538-reheat-coil-valve-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-523-hot-water-out-connection"
+ "@id": "urn:ex/vav-538-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -24562,130 +24659,120 @@
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-523-hot-water-out"
+ "@id": "urn:ex/vav-538-hot-water-out"
}
]
},
{
- "@id": "urn:ex/vav-538-discharge-air-flow-sensor",
+ "@id": "urn:ex/room-110-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-538-air-in"
+ "@id": "urn:ex/room-110-in"
+ },
+ {
+ "@id": "urn:ex/room-110-out"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:ex/vav-538-discharge-air-flow"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-507-reheat-coil-valve-actuator",
+ "@id": "urn:ex/vav-505-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-507-reheat-coil-valve"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-507-reheat-coil-valve-command"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/office-ahu-oa-in-connection",
+ "@id": "urn:ex/vav-534-pipe-hot-water-return-before-valve",
"@type": [
"http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-501-reheat-coil-valve-position",
+ "@id": "urn:ex/vav-504-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/vav-504-reheat-coil-valve"
}
- ]
- },
- {
- "@id": "urn:ex/vav-540-hot-water-in-connection",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-504-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/vav-532-air-in",
+ "@id": "urn:ex/vav-521-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-521-reheat-coil-valve"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-521-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/vav-531-discharge-air-temp-setpoint",
+ "@id": "urn:ex/vav-528-reheat-coil-valve-command",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-501-duct-after-damper",
+ "@id": "urn:ex/room-210",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/room-210-hvac-domain"
}
]
},
{
- "@id": "urn:ex/zone-115-cooling-setpoint",
+ "@id": "urn:ex/zone-106-107-temp",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -24699,127 +24786,93 @@
]
},
{
- "@id": "urn:ex/zone-101-co2-concentration-setpoint",
+ "@id": "urn:ex/vav-531-reheat-coil-valve-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://data.ashrae.org/standard223#ofSubstance": [
- {
- "@id": "http://data.ashrae.org/standard223#Substance-CO2"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/MoleFraction"
+ "@id": "urn:ex/vav-531-hot-water-out-connection"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PPM"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
- ]
- },
- {
- "@id": "urn:ex/vav-534-more-heat-requests",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/vav-531-hot-water-out"
}
]
},
{
- "@id": "urn:ex/vav-531-reheat-coil-water-out",
+ "@id": "urn:ex/zone-311-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-531-pipe-hot-water-return-before-valve"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/zone-206-occupancy-override",
+ "@id": "urn:ex/vav-506-pipe-hot-water-return-before-valve",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-514-air-out",
+ "@id": "urn:ex/room-313",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/connection-to-room-115"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-514-discharge-air-flow"
- },
- {
- "@id": "urn:ex/vav-514-discharge-air-flow-setpoint"
- },
- {
- "@id": "urn:ex/vav-514-discharge-air-temp"
- },
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "urn:ex/vav-514-discharge-air-temp-setpoint"
+ "@id": "urn:ex/room-313-hvac-domain"
}
]
},
{
- "@id": "urn:ex/vav-537-reheat-coil-valve-out",
+ "@id": "urn:ex/vav-535-air-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-537-hot-water-out-connection"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-537-hot-water-out"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-518-reheat-coil-valve",
+ "@id": "urn:ex/vav-540-reheat-coil-valve",
"@type": [
"http://data.ashrae.org/standard223#Valve",
"http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-518-reheat-coil-valve-in"
+ "@id": "urn:ex/vav-540-reheat-coil-valve-in"
},
{
- "@id": "urn:ex/vav-518-reheat-coil-valve-out"
+ "@id": "urn:ex/vav-540-reheat-coil-valve-out"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -24829,214 +24882,236 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-518-reheat-coil-valve-command"
+ "@id": "urn:ex/vav-540-reheat-coil-valve-command"
},
{
- "@id": "urn:ex/vav-518-reheat-coil-valve-position"
+ "@id": "urn:ex/vav-540-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/zone-115-occupancy-sensor",
+ "@id": "urn:ex/vav-521-cooling-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-115-hvac-domain"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/zone-115-occupancy"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/zone-112-114",
+ "@id": "urn:ex/room-311-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-112-hvac-domain"
+ "@id": "urn:ex/room-311-in"
},
{
- "@id": "urn:ex/room-114-hvac-domain"
+ "@id": "urn:ex/room-311-out"
}
],
"http://data.ashrae.org/standard223#hasDomain": [
{
"@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-539-reheat-coil",
+ "@type": [
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/zone-112-114-cooling-setpoint"
- },
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/zone-112-114-heating-setpoint"
+ "@id": "urn:ex/vav-539-reheat-coil-air-in"
},
{
- "@id": "urn:ex/zone-112-114-occupancy"
+ "@id": "urn:ex/vav-539-reheat-coil-air-out"
},
{
- "@id": "urn:ex/zone-112-114-occupancy-override"
+ "@id": "urn:ex/vav-539-reheat-coil-water-in"
},
{
- "@id": "urn:ex/zone-112-114-temp"
- },
+ "@id": "urn:ex/vav-539-reheat-coil-water-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "urn:ex/zone-112-114-window-switch-on-off"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/vav-539-damper-actuator",
+ "@id": "urn:ex/vav-523-damper",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-539-damper"
+ "@id": "urn:ex/vav-523-damper-in"
+ },
+ {
+ "@id": "urn:ex/vav-523-damper-out"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-539-damper-command"
+ "@id": "urn:ex/vav-523-damper-command"
+ },
+ {
+ "@id": "urn:ex/vav-523-damper-position"
}
]
},
{
- "@id": "urn:ex/vav-510-damper-out",
+ "@id": "urn:ex/vav-529-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-510-duct-after-damper"
+ "@id": "urn:ex/vav-529-air-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-529-discharge-air-temp"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/room-301",
+ "@type": [
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-510-colder-supply-air-requests"
- },
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "urn:ex/vav-510-cooling-pid-output"
+ "@id": "urn:ex/room-301-hvac-domain"
}
]
},
{
- "@id": "urn:ex/vav-522-reheat-coil-valve",
+ "@id": "urn:ex/vav-519-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/vav-522-reheat-coil-valve-in"
- },
+ "@id": "urn:ex/vav-519-reheat-coil-valve"
+ }
+ ],
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/vav-522-reheat-coil-valve-out"
+ "@id": "urn:ex/vav-519-reheat-coil-valve-command"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-512-duct-after-damper",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-526-reheat-coil-valve-command",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-522-reheat-coil-valve-command"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-522-reheat-coil-valve-position"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/room-306-hvac-domain",
+ "@id": "urn:ex/vav-526-discharge-air-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/room-306-in"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-306-out"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-508-more-heat-requests",
+ "@id": "urn:ex/zone-215-window-switch-on-off",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/vav-536-reheat-coil-air-out",
+ "@id": "urn:ex/room-112-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-313"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-536-heating-pid-output"
- },
- {
- "@id": "urn:ex/vav-536-more-heat-requests"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-536-air-out"
- }
]
},
{
- "@id": "urn:ex/vav-523-discharge-air-flow-sensor",
+ "@id": "urn:ex/zone-106-107-occupancy",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-523-air-in"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/office-ahu-pipe-hot-water-return-before-valve",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-523-discharge-air-flow"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-531-reheat-coil-valve-command",
+ "@id": "urn:ex/vav-539-reheat-coil-valve-command",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -25052,260 +25127,293 @@
]
},
{
- "@id": "urn:ex/vav-510-more-heat-requests",
+ "@id": "urn:ex/vav-524-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/vav-524-reheat-coil-valve-in"
+ },
+ {
+ "@id": "urn:ex/vav-524-reheat-coil-valve-out"
}
- ]
- },
- {
- "@id": "urn:ex/zone-101-occupancy",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-524-reheat-coil-valve-command"
+ },
+ {
+ "@id": "urn:ex/vav-524-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/room-112-in",
+ "@id": "urn:ex/vav-537-reheat-coil-valve-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-112-114"
+ "@id": "urn:ex/vav-537-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-539-discharge-air-temp",
+ "@id": "urn:ex/vav-521-reheat-coil-valve-position",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
- ],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-523-damper-actuator",
+ "@id": "urn:ex/vav-501-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-523-damper"
+ "@id": "urn:ex/vav-501-hot-water-in-connection"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-523-damper-command"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
- ]
- },
- {
- "@id": "urn:ex/zone-105-window-switch-on-off",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "urn:ex/vav-501-hot-water-in"
}
]
},
{
- "@id": "urn:ex/zone-203-temp",
+ "@id": "urn:ex/vav-508",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-508-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-508-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-508-hot-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-508-hot-water-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-508-damper"
+ },
+ {
+ "@id": "urn:ex/vav-508-reheat-coil"
+ },
+ {
+ "@id": "urn:ex/vav-508-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/vav-515-hot-water-in-connection",
+ "@id": "urn:ex/vav-536-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-536-reheat-coil-valve"
}
- ]
- },
- {
- "@id": "urn:ex/zone-208-209-occupancy",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "urn:ex/vav-536-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/vav-505-hot-water-out-connection",
+ "@id": "urn:ex/vav-537-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-537-reheat-coil-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-537-reheat-coil-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-537-reheat-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-537-reheat-coil-water-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasRole": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/vav-516-damper-command",
+ "@id": "urn:ex/vav-534-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-534-hot-water-in-connection"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-534-hot-water-in"
}
]
},
{
- "@id": "urn:ex/vav-514-reheat-coil-air-in",
+ "@id": "urn:ex/zone-103-temp",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-514-duct-after-damper"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-516-reheat-coil-air-out",
+ "@id": "urn:ex/vav-538-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-201"
+ "@id": "urn:ex/vav-538-reheat-coil-valve-in"
+ },
+ {
+ "@id": "urn:ex/vav-538-reheat-coil-valve-out"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-516-heating-pid-output"
+ "@id": "urn:ex/vav-538-reheat-coil-valve-command"
},
{
- "@id": "urn:ex/vav-516-more-heat-requests"
+ "@id": "urn:ex/vav-538-reheat-coil-valve-position"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/office-ahu-ra-damper-command",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-516-air-out"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-525-air-in",
+ "@id": "urn:ex/vav-520-reheat-coil-valve-position",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-512-cooling-pid-output",
+ "@id": "urn:ex/vav-523-reheat-coil-valve-position",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/office-ahu-ea-damper-out",
+ "@id": "urn:ex/room-208-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-ea-out-connection"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/office-ahu-ea-out"
- }
]
},
{
- "@id": "urn:ex/zone-302-temp",
+ "@id": "urn:ex/zone-314-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -25319,126 +25427,176 @@
]
},
{
- "@id": "urn:ex/vav-503-more-heat-requests",
+ "@id": "urn:ex/vav-527-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/vav-527-reheat-coil-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-527-reheat-coil-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-527-reheat-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-527-reheat-coil-water-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasRole": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/connection-to-room-302",
+ "@id": "urn:ex/vav-528-heating-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-511-damper-command",
+ "@id": "urn:ex/vav-502-discharge-air-flow-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/office-ahu-ea-damper-command",
+ "@id": "urn:ex/zone-204-205-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/room-204-hvac-domain"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/zone-204-205-temp"
}
]
},
{
- "@id": "urn:ex/zone-202",
+ "@id": "urn:ex/vav-513-reheat-coil-air-out",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-202-hvac-domain"
+ "@id": "urn:ex/connection-to-room-103"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/zone-202-cooling-setpoint"
+ "@id": "urn:ex/vav-513-heating-pid-output"
},
{
- "@id": "urn:ex/zone-202-heating-setpoint"
- },
+ "@id": "urn:ex/vav-513-more-heat-requests"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/zone-202-occupancy"
- },
+ "@id": "urn:ex/vav-513-air-out"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-517-hot-water-out-connection",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-202-occupancy-override"
- },
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/room-107-in",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/zone-202-temp"
- },
+ "@id": "urn:ex/connection-to-room-106-107"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-202-window-switch-on-off"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-530-damper-in",
+ "@id": "urn:ex/vav-528-reheat-coil-valve-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-528-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-505-reheat-coil-valve-actuator",
+ "@type": [
+ "http://data.ashrae.org/standard223#Actuator"
+ ],
+ "http://data.ashrae.org/standard223#actuates": [
+ {
+ "@id": "urn:ex/vav-505-reheat-coil-valve"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/vav-530-air-in"
+ "@id": "urn:ex/vav-505-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/vav-504-damper-out",
+ "@id": "urn:ex/vav-510-damper-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-504-duct-after-damper"
+ "@id": "urn:ex/vav-510-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -25448,26 +25606,15 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-504-colder-supply-air-requests"
+ "@id": "urn:ex/vav-510-colder-supply-air-requests"
},
{
- "@id": "urn:ex/vav-504-cooling-pid-output"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-502-colder-supply-air-requests",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/vav-510-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/vav-505-discharge-air-flow",
+ "@id": "urn:ex/vav-504-discharge-air-flow",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -25488,20 +25635,25 @@
]
},
{
- "@id": "urn:ex/zone-307-308-window-switch-on-off",
+ "@id": "urn:ex/zone-311-occupancy-sensor",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "urn:ex/room-311-hvac-domain"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:ex/zone-311-occupancy"
}
]
},
{
- "@id": "urn:ex/vav-510-reheat-coil-valve-position",
+ "@id": "urn:ex/vav-514-damper-command",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -25515,13 +25667,13 @@
]
},
{
- "@id": "urn:ex/vav-531-hot-water-in",
+ "@id": "urn:ex/vav-515-hot-water-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-531-hot-water-in-connection"
+ "@id": "urn:ex/vav-515-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -25531,143 +25683,184 @@
]
},
{
- "@id": "urn:ex/vav-507-damper-in",
+ "@id": "urn:ex/vav-512-reheat-coil-valve-position",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-110-cooling-setpoint",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-507-air-in"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-510-hot-water-in-connection",
+ "@id": "urn:ex/vav-517-reheat-coil-air-out",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/connection-to-room-203"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-517-heating-pid-output"
+ },
+ {
+ "@id": "urn:ex/vav-517-more-heat-requests"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-517-air-out"
}
]
},
{
- "@id": "urn:ex/office-ahu-clg-coil-valve",
+ "@id": "urn:ex/vav-526-reheat-coil-valve",
"@type": [
"http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#ChilledWaterValve"
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-clg-coil-valve-in"
+ "@id": "urn:ex/vav-526-reheat-coil-valve-in"
},
{
- "@id": "urn:ex/office-ahu-clg-coil-valve-out"
+ "@id": "urn:ex/vav-526-reheat-coil-valve-out"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-ChilledWater"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/office-ahu-clg-coil-valve-command"
+ "@id": "urn:ex/vav-526-reheat-coil-valve-command"
},
{
- "@id": "urn:ex/office-ahu-clg-coil-valve-position"
+ "@id": "urn:ex/vav-526-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-525-discharge-air-flow-sensor",
+ "@id": "urn:ex/vav-517-hot-water-in-connection",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:ex/vav-525-air-in"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-525-discharge-air-flow"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/zone-313-occupancy-override",
+ "@id": "urn:ex/office-ahu-clg-coil-valve-position",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/room-301-out",
+ "@id": "urn:ex/vav-533-damper-command",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-531-discharge-air-flow-sensor",
+ "@id": "urn:ex/vav-539-reheat-coil-valve-position",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-531-air-in"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-531-discharge-air-flow"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-515-hot-water-out",
+ "@id": "urn:ex/vav-528-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-515-hot-water-out-connection"
+ "@id": "urn:ex/vav-528-reheat-coil-valve-in"
+ },
+ {
+ "@id": "urn:ex/vav-528-reheat-coil-valve-out"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-528-reheat-coil-valve-command"
+ },
+ {
+ "@id": "urn:ex/vav-528-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-505-hot-water-in-connection",
+ "@id": "urn:ex/vav-515-hot-water-out-connection",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Pipe"
@@ -25679,7 +25872,7 @@
]
},
{
- "@id": "urn:ex/zone-307-308-temp",
+ "@id": "urn:ex/zone-115-temp",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -25695,187 +25888,202 @@
]
},
{
- "@id": "urn:ex/zone-313-occupancy",
+ "@id": "urn:ex/vav-526-reheat-coil-valve-position",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-508-reheat-coil-valve",
+ "@id": "urn:ex/vav-503-discharge-air-flow-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-508-reheat-coil-valve-in"
- },
- {
- "@id": "urn:ex/vav-508-reheat-coil-valve-out"
- }
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-508-reheat-coil-valve-command"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-508-reheat-coil-valve-position"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/room-108",
+ "@id": "urn:ex/vav-529-cooling-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-108-hvac-domain"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/zone-101-temp",
+ "@id": "urn:ex/vav-536-damper-command",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/zone-210-occupancy-override",
+ "@id": "urn:ex/room-312-in",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "urn:ex/connection-to-room-312"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/room-302-in",
+ "@id": "urn:ex/vav-525-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/connection-to-room-302"
+ "@id": "urn:ex/vav-525-reheat-coil-valve"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-525-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/vav-503-reheat-coil-air-in",
+ "@id": "urn:ex/zone-305-occupancy",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ {
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-533-hot-water-out",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-503-duct-after-damper"
+ "@id": "urn:ex/vav-533-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/zone-102-occupancy-sensor",
+ "@id": "urn:ex/vav-529-hot-water-in-connection",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/room-102-hvac-domain"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/office-ahu-oa-in-connection",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-102-occupancy"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-512-reheat-coil-valve-actuator",
+ "@id": "urn:ex/vav-509-reheat-coil-valve-actuator",
"@type": [
"http://data.ashrae.org/standard223#Actuator"
],
"http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/vav-512-reheat-coil-valve"
+ "@id": "urn:ex/vav-509-reheat-coil-valve"
}
],
"http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/vav-512-reheat-coil-valve-command"
+ "@id": "urn:ex/vav-509-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/room-205-out",
+ "@id": "urn:ex/vav-510-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/vav-510-reheat-coil-valve"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-510-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/zone-105-occupancy-override",
+ "@id": "urn:ex/zone-104-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
- ]
- },
- {
- "@id": "urn:ex/vav-511-hot-water-out-connection",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/office-ahu-htg-coil-valve-position",
+ "@id": "urn:ex/vav-532-reheat-coil-valve-position",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -25891,143 +26099,145 @@
]
},
{
- "@id": "urn:ex/vav-507-reheat-coil-air-out",
+ "@id": "urn:ex/vav-538-discharge-air-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/connection-to-room-110"
- }
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-507-heating-pid-output"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-507-more-heat-requests"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-537-more-heat-requests",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-507-air-out"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-517-hot-water-in",
+ "@id": "urn:ex/vav-511-heating-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-517-hot-water-in-connection"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-511-reheat-coil-valve-command",
+ "@id": "urn:ex/vav-534-discharge-air-flow",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasAspect": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/office-ahu-air-filter",
+ "@id": "urn:ex/zone-201-occupancy",
"@type": [
- "http://data.ashrae.org/standard223#AirFilter",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Filter"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/office-ahu-air-filter-in"
- },
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/office-ahu-air-filter-out"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
]
},
{
- "@id": "urn:ex/room-304-in",
+ "@id": "urn:ex/vav-524-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-303-304-306"
+ "@id": "urn:ex/vav-524-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-529-reheat-coil-valve-out",
+ "@id": "urn:ex/vav-524-damper-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-529-hot-water-out-connection"
+ "@id": "urn:ex/vav-524-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-529-hot-water-out"
+ "@id": "urn:ex/vav-524-colder-supply-air-requests"
+ },
+ {
+ "@id": "urn:ex/vav-524-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/vav-528-discharge-air-flow",
+ "@id": "urn:ex/zone-112-114-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/zone-311-heating-setpoint",
+ "@id": "urn:ex/vav-502-discharge-air-temp",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasAspect": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -26041,34 +26251,23 @@
]
},
{
- "@id": "urn:ex/vav-505-damper-actuator",
+ "@id": "urn:ex/vav-518-discharge-air-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
- ],
- "http://data.ashrae.org/standard223#actuates": [
- {
- "@id": "urn:ex/vav-505-damper"
- }
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-505-damper-command"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
- ]
- },
- {
- "@id": "urn:ex/room-212",
- "@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/room-212-hvac-domain"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/office-ahu-pipe-chilled-water-return-before-valve",
+ "@id": "urn:ex/vav-540-pipe-hot-water-return-before-valve",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Pipe"
@@ -26080,51 +26279,39 @@
]
},
{
- "@id": "urn:ex/vav-512-damper-actuator",
+ "@id": "urn:ex/zone-208-209-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
- ],
- "http://data.ashrae.org/standard223#actuates": [
- {
- "@id": "urn:ex/vav-512-damper"
- }
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-512-damper-command"
+ "@id": "urn:ex/room-208-hvac-domain"
}
- ]
- },
- {
- "@id": "urn:ex/vav-523-hot-water-out-connection",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/zone-208-209-temp"
}
]
},
{
- "@id": "urn:ex/zone-301-cooling-setpoint",
+ "@id": "urn:ex/room-312-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-507-damper-position",
+ "@id": "urn:ex/vav-518-damper-position",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -26140,32 +26327,25 @@
]
},
{
- "@id": "urn:ex/vav-514-damper",
+ "@id": "urn:ex/vav-532-heating-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-514-damper-in"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-514-damper-out"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-514-damper-command"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-514-damper-position"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/office-ahu-sa-fan-speed-status",
+ "@id": "urn:ex/vav-531-reheat-coil-valve-command",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -26179,59 +26359,42 @@
]
},
{
- "@id": "urn:ex/room-210-hvac-domain",
+ "@id": "urn:ex/vav-512-reheat-coil-air-out",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-210-in"
- },
- {
- "@id": "urn:ex/room-210-out"
+ "@id": "urn:ex/connection-to-room-118"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/vav-527-more-heat-requests",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-531-reheat-coil-valve-actuator",
- "@type": [
- "http://data.ashrae.org/standard223#Actuator"
- ],
- "http://data.ashrae.org/standard223#actuates": [
+ "@id": "urn:ex/vav-512-heating-pid-output"
+ },
{
- "@id": "urn:ex/vav-531-reheat-coil-valve"
+ "@id": "urn:ex/vav-512-more-heat-requests"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-531-reheat-coil-valve-command"
+ "@id": "urn:ex/vav-512-air-out"
}
]
},
{
- "@id": "urn:ex/vav-503-reheat-coil-air-out",
+ "@id": "urn:ex/vav-531-reheat-coil-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-104"
+ "@id": "urn:ex/connection-to-room-307-308"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -26241,20 +26404,46 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-503-heating-pid-output"
+ "@id": "urn:ex/vav-531-heating-pid-output"
},
{
- "@id": "urn:ex/vav-503-more-heat-requests"
+ "@id": "urn:ex/vav-531-more-heat-requests"
}
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-503-air-out"
+ "@id": "urn:ex/vav-531-air-out"
}
]
},
{
- "@id": "urn:ex/vav-538-discharge-air-flow",
+ "@id": "urn:ex/vav-530-reheat-coil",
+ "@type": [
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-530-reheat-coil-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-530-reheat-coil-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-530-reheat-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-530-reheat-coil-water-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasRole": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-521-discharge-air-temp",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -26265,34 +26454,39 @@
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-514-colder-supply-air-requests",
+ "@id": "urn:ex/vav-537-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/vav-537-reheat-coil-valve"
+ }
+ ],
+ "http://data.ashrae.org/standard223#commandedByProperty": [
+ {
+ "@id": "urn:ex/vav-537-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/room-105-in",
+ "@id": "urn:ex/room-303-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-105"
+ "@id": "urn:ex/connection-to-room-303-304-306"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -26302,152 +26496,147 @@
]
},
{
- "@id": "urn:ex/vav-532-hot-water-out-connection",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-524-damper-command",
+ "@id": "urn:ex/vav-510-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-510-damper"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/vav-510-damper-command"
}
]
},
{
- "@id": "urn:ex/zone-118-occupancy-sensor",
+ "@id": "urn:ex/vav-501-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-118-hvac-domain"
+ "@id": "urn:ex/vav-501-reheat-coil-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-501-reheat-coil-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-501-reheat-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-501-reheat-coil-water-out"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "urn:ex/zone-118-occupancy"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/vav-512-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-521",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-512-pipe-hot-water-return-before-valve"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:ex/vav-521-air-in"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-521-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-521-hot-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-521-hot-water-out"
}
- ]
- },
- {
- "@id": "urn:ex/vav-525-hot-water-in-connection",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-521-damper"
+ },
+ {
+ "@id": "urn:ex/vav-521-reheat-coil"
+ },
+ {
+ "@id": "urn:ex/vav-521-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/vav-524-air-in",
+ "@id": "urn:ex/vav-507-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-507-reheat-coil-valve"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-507-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/office-ahu-sa-temp-setpoint",
+ "@id": "urn:ex/vav-529-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-529-reheat-coil-valve"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-529-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/room-107-hvac-domain",
+ "@id": "urn:ex/connection-to-room-213",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/room-107-in"
- },
- {
- "@id": "urn:ex/room-107-out"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-507-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-513-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-507-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/room-118-out",
+ "@id": "urn:ex/vav-528-reheat-coil-air-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/vav-528-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -26457,102 +26646,68 @@
]
},
{
- "@id": "urn:ex/zone-215-cooling-setpoint",
+ "@id": "urn:ex/vav-508-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-508-air-in"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-508-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/office-ahu-sa-fan-out",
+ "@id": "urn:ex/office-ahu-sa-fan",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Fan",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#FanWithVFD"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "@id": "urn:ex/office-ahu-sa-fan-in"
+ },
{
- "@id": "urn:ex/office-ahu-sa-out"
+ "@id": "urn:ex/office-ahu-sa-fan-out"
}
- ]
- },
- {
- "@id": "urn:ex/vav-528-reheat-coil-valve",
- "@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-528-reheat-coil-valve-in"
+ "@id": "urn:ex/office-ahu-sa-fan-power"
},
{
- "@id": "urn:ex/vav-528-reheat-coil-valve-out"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:ex/office-ahu-sa-fan-speed-cmd"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "@id": "urn:ex/office-ahu-sa-fan-speed-status"
+ },
{
- "@id": "urn:ex/vav-528-reheat-coil-valve-command"
+ "@id": "urn:ex/office-ahu-sa-fan-start-cmd"
},
{
- "@id": "urn:ex/vav-528-reheat-coil-valve-position"
+ "@id": "urn:ex/office-ahu-sa-fan-start-status"
}
- ]
- },
- {
- "@id": "urn:ex/vav-504-hot-water-out-connection",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Role-Supply"
}
]
},
{
- "@id": "urn:ex/vav-528-discharge-air-flow-setpoint",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
- {
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
- }
+ "@id": "http://data.ashrae.org/standard223#Role-Outside",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumerationKind-Role"
]
},
{
- "@id": "urn:ex/vav-509-damper-position",
+ "@id": "urn:ex/vav-502-damper-command",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -26566,29 +26721,29 @@
]
},
{
- "@id": "urn:ex/vav-531-damper-actuator",
+ "@id": "urn:ex/vav-538-air-in",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-531-damper"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-531-damper-command"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/room-110-in",
+ "@id": "urn:ex/room-214-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-110"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -26598,234 +26753,252 @@
]
},
{
- "@id": "urn:ex/vav-530-reheat-coil-valve-command",
+ "@id": "urn:ex/vav-527-cooling-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-505-reheat-coil-air-in",
+ "@id": "urn:ex/zone-116-117-cooling-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-505-duct-after-damper"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-533-pipe-hot-water-return-before-valve",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-539-reheat-coil-water-in",
+ "@id": "urn:ex/vav-501-reheat-coil-valve-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-539-hot-water-in-connection"
+ "@id": "urn:ex/vav-501-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-539-hot-water-in"
- }
]
},
{
- "@id": "urn:ex/office-ahu-duct-after-moisture-eliminator",
+ "@id": "urn:ex/vav-526-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-526-hot-water-out-connection"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-521-damper",
+ "@id": "urn:ex/vav-521-air-out",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-521-damper-in"
- },
+ "@id": "urn:ex/connection-to-room-204-205"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-521-damper-out"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-521-damper-command"
+ "@id": "urn:ex/vav-521-discharge-air-flow"
},
{
- "@id": "urn:ex/vav-521-damper-position"
+ "@id": "urn:ex/vav-521-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-521-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-521-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/vav-523-damper-command",
+ "@id": "urn:ex/vav-533-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-533-pipe-hot-water-return-before-valve"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-524-discharge-air-flow-setpoint",
+ "@id": "urn:ex/office-ahu-ra-damper",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:ex/office-ahu-ra-damper-in"
+ },
+ {
+ "@id": "urn:ex/office-ahu-ra-damper-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:ex/office-ahu-ra-damper-command"
+ },
+ {
+ "@id": "urn:ex/office-ahu-ra-damper-position"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasRole": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Return"
}
]
},
{
- "@id": "urn:ex/vav-502-cooling-pid-output",
+ "@id": "urn:ex/vav-524-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/vav-524-reheat-coil-valve"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "urn:ex/vav-524-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/vav-526-reheat-coil-valve-command",
+ "@id": "urn:ex/vav-536-pipe-hot-water-return-before-valve",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/office-ahu-htg-coil-air-out",
+ "@id": "urn:ex/vav-515-damper-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-duct-after-htg-coil"
+ "@id": "urn:ex/vav-515-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/room-310",
- "@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/room-310-hvac-domain"
+ "@id": "urn:ex/vav-515-colder-supply-air-requests"
+ },
+ {
+ "@id": "urn:ex/vav-515-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/office-ahu-sa-fan-power",
+ "@id": "urn:ex/vav-524-damper-position",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/W"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-538-colder-supply-air-requests",
+ "@id": "urn:ex/room-211",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/room-211-hvac-domain"
}
]
},
{
- "@id": "urn:ex/vav-516-reheat-coil-valve-out",
+ "@id": "urn:ex/room-209-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-516-hot-water-out-connection"
+ "@id": "urn:ex/connection-to-room-208-209"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-516-hot-water-out"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-534-damper-command",
+ "@id": "urn:ex/vav-527-reheat-coil-valve-command",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -26841,7 +27014,19 @@
]
},
{
- "@id": "urn:ex/vav-524-discharge-air-temp-setpoint",
+ "@id": "urn:ex/vav-523-hot-water-in-connection",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-206-cooling-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -26857,407 +27042,404 @@
]
},
{
- "@id": "urn:ex/vav-533-reheat-coil-air-in",
+ "@id": "urn:ex/zone-112-114-temp",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-533-duct-after-damper"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-535-discharge-air-flow",
+ "@id": "urn:ex/vav-519-hot-water-in-connection",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-110-window-switch-on-off",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/vav-530-reheat-coil-water-in",
+ "@id": "urn:ex/room-207-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-530-hot-water-in-connection"
+ "@id": "urn:ex/connection-to-room-207"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-530-hot-water-in"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/room-311-out",
+ "@id": "urn:ex/vav-512-damper-command",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-513-reheat-coil-valve",
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#EnumerationKind"
+ ]
+ },
+ {
+ "@id": "urn:ex/office-ahu-clg-coil-water-in",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-513-reheat-coil-valve-in"
- },
- {
- "@id": "urn:ex/vav-513-reheat-coil-valve-out"
+ "@id": "urn:ex/office-ahu-chilled-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-513-reheat-coil-valve-command"
- },
+ "@id": "urn:ex/office-ahu-colder-chilled-water-requests"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-513-reheat-coil-valve-position"
+ "@id": "urn:ex/office-ahu-chilled-water-in"
}
]
},
{
- "@id": "urn:ex/vav-514-damper-actuator",
+ "@id": "urn:ex/vav-521-damper-command",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-514-damper"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-514-damper-command"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/office-ahu-ra-flow",
+ "@id": "urn:ex/zone-105",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Return"
+ "@id": "urn:ex/room-105-hvac-domain"
}
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:ex/zone-105-cooling-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-105-heating-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-105-occupancy"
+ },
+ {
+ "@id": "urn:ex/zone-105-occupancy-override"
+ },
+ {
+ "@id": "urn:ex/zone-105-temp"
+ },
+ {
+ "@id": "urn:ex/zone-105-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-511-discharge-air-flow",
+ "@id": "urn:ex/vav-510-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:ex/vav-510-air-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:ex/vav-510-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/vav-504-discharge-air-temp-setpoint",
+ "@id": "urn:ex/vav-502-reheat-coil-valve-command",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-519-damper",
+ "@id": "urn:ex/vav-509-air-out",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-519-damper-in"
- },
+ "@id": "urn:ex/connection-to-room-113"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-519-damper-out"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-519-damper-command"
+ "@id": "urn:ex/vav-509-discharge-air-flow"
},
{
- "@id": "urn:ex/vav-519-damper-position"
+ "@id": "urn:ex/vav-509-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-509-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-509-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "http://data.ashrae.org/standard223#Role-Outside",
- "@type": [
- "http://data.ashrae.org/standard223#EnumerationKind-Role"
- ]
- },
- {
- "@id": "urn:ex/zone-106-107-temp-sensor",
+ "@id": "urn:ex/zone-302-occupancy",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:ex/room-106-hvac-domain"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/zone-106-107-temp"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
]
},
{
- "@id": "urn:ex/vav-523-hot-water-in",
+ "@id": "urn:ex/vav-532-reheat-coil-air-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-523-hot-water-in-connection"
+ "@id": "urn:ex/connection-to-room-309-310"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/zone-301-temp",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-532-heating-pid-output"
+ },
+ {
+ "@id": "urn:ex/vav-532-more-heat-requests"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-532-air-out"
}
]
},
{
- "@id": "urn:ex/vav-528-damper-actuator",
+ "@id": "urn:ex/vav-532-more-heat-requests",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
- ],
- "http://data.ashrae.org/standard223#actuates": [
- {
- "@id": "urn:ex/vav-528-damper"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-528-damper-command"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-519-hot-water-in-connection",
+ "@id": "urn:ex/vav-533-air-in",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-534-discharge-air-temp-setpoint",
+ "@id": "urn:ex/vav-502-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-502-damper"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-502-damper-command"
}
]
},
{
- "@id": "urn:ex/zone-305-cooling-setpoint",
+ "@id": "urn:ex/vav-511-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-511-air-in"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-511-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/vav-521-damper-command",
+ "@id": "urn:ex/vav-503-more-heat-requests",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-506-damper",
+ "@id": "urn:ex/vav-525-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-506-damper-in"
- },
+ "http://data.ashrae.org/standard223#Sensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-506-damper-out"
+ "@id": "urn:ex/vav-525-air-in"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-506-damper-command"
- },
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-506-damper-position"
+ "@id": "urn:ex/vav-525-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/vav-530-cooling-pid-output",
+ "@id": "urn:ex/vav-540-reheat-coil-valve-command",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-533-discharge-air-temp-sensor",
+ "@id": "urn:ex/vav-532-reheat-coil-valve-out",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-533-air-out"
+ "@id": "urn:ex/vav-532-hot-water-out-connection"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-533-discharge-air-temp"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-532-hot-water-out"
}
]
},
{
- "@id": "urn:ex/vav-515-reheat-coil-valve-actuator",
+ "@id": "urn:ex/zone-206-temp",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-515-reheat-coil-valve"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-515-reheat-coil-valve-command"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-530-more-heat-requests",
+ "@id": "urn:ex/vav-522-colder-supply-air-requests",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
@@ -27268,28 +27450,23 @@
]
},
{
- "@id": "urn:ex/vav-526-discharge-air-temp",
+ "@id": "urn:ex/room-212-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/connection-to-room-212"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/room-101-out",
+ "@id": "urn:ex/room-209-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -27305,89 +27482,83 @@
]
},
{
- "@id": "urn:ex/zone-215-heating-setpoint",
+ "@id": "urn:ex/vav-508-air-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/connection-to-room-109"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/vav-520-reheat-coil-valve",
- "@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-520-reheat-coil-valve-in"
+ "@id": "urn:ex/vav-508-discharge-air-flow"
},
{
- "@id": "urn:ex/vav-520-reheat-coil-valve-out"
+ "@id": "urn:ex/vav-508-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-508-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-508-discharge-air-temp-setpoint"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-102-occupancy-sensor",
+ "@type": [
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "urn:ex/room-102-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-520-reheat-coil-valve-command"
- },
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-520-reheat-coil-valve-position"
+ "@id": "urn:ex/zone-102-occupancy"
}
]
},
{
- "@id": "urn:ex/vav-516",
+ "@id": "urn:ex/vav-516-hot-water-in-connection",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-516-air-in"
- },
- {
- "@id": "urn:ex/vav-516-air-out"
- },
- {
- "@id": "urn:ex/vav-516-hot-water-in"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-516-hot-water-out"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-527-pipe-hot-water-return-before-valve",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/vav-516-damper"
- },
- {
- "@id": "urn:ex/vav-516-reheat-coil"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-516-reheat-coil-valve"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-513-hot-water-in",
+ "@id": "urn:ex/vav-531-hot-water-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-513-hot-water-in-connection"
+ "@id": "urn:ex/vav-531-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -27397,23 +27568,39 @@
]
},
{
- "@id": "urn:ex/vav-514-cooling-pid-output",
+ "@id": "urn:ex/vav-503-damper-position",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-517-discharge-air-flow-setpoint",
+ "@id": "urn:ex/vav-518-hot-water-in",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-518-hot-water-in-connection"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-505-discharge-air-flow-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -27429,64 +27616,45 @@
]
},
{
- "@id": "urn:ex/zone-116-117-occupancy",
+ "@id": "urn:ex/vav-514-reheat-coil-valve-position",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/zone-309-310",
+ "@id": "urn:ex/vav-529-air-in",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
- ],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/room-309-hvac-domain"
- },
- {
- "@id": "urn:ex/room-310-hvac-domain"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/zone-309-310-cooling-setpoint"
- },
- {
- "@id": "urn:ex/zone-309-310-heating-setpoint"
- },
- {
- "@id": "urn:ex/zone-309-310-occupancy"
- },
- {
- "@id": "urn:ex/zone-309-310-occupancy-override"
- },
- {
- "@id": "urn:ex/zone-309-310-temp"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-309-310-window-switch-on-off"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-531-reheat-coil-water-in",
+ "@id": "urn:ex/vav-540-reheat-coil-valve-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-531-hot-water-in-connection"
+ "@id": "urn:ex/vav-540-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -27496,63 +27664,72 @@
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-531-hot-water-in"
+ "@id": "urn:ex/vav-540-hot-water-out"
}
]
},
{
- "@id": "urn:ex/vav-536-hot-water-out-connection",
+ "@id": "urn:ex/vav-507-reheat-coil-air-in",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-507-duct-after-damper"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-536-damper",
+ "@id": "urn:ex/vav-514-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-536-damper-in"
+ "@id": "urn:ex/vav-514-reheat-coil-valve-in"
},
{
- "@id": "urn:ex/vav-536-damper-out"
+ "@id": "urn:ex/vav-514-reheat-coil-valve-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-536-damper-command"
+ "@id": "urn:ex/vav-514-reheat-coil-valve-command"
},
{
- "@id": "urn:ex/vav-536-damper-position"
+ "@id": "urn:ex/vav-514-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-535-discharge-air-flow-setpoint",
+ "@id": "urn:ex/vav-503-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:ex/vav-503-hot-water-out-connection"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-514-damper-in",
+ "@id": "urn:ex/vav-516-damper-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -27568,187 +27745,195 @@
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-514-air-in"
+ "@id": "urn:ex/vav-516-air-in"
}
]
},
{
- "@id": "urn:ex/vav-522-reheat-coil-valve-actuator",
+ "@id": "urn:ex/vav-517-damper",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-522-reheat-coil-valve"
+ "@id": "urn:ex/vav-517-damper-in"
+ },
+ {
+ "@id": "urn:ex/vav-517-damper-out"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-522-reheat-coil-valve-command"
+ "@id": "urn:ex/vav-517-damper-command"
+ },
+ {
+ "@id": "urn:ex/vav-517-damper-position"
}
]
},
{
- "@id": "urn:ex/vav-521-discharge-air-temp",
+ "@id": "urn:ex/vav-513-damper-command",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-534-duct-after-damper",
+ "@id": "urn:ex/vav-523-more-heat-requests",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-525-reheat-coil-water-in",
+ "@id": "urn:ex/room-306-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-525-hot-water-in-connection"
+ "@id": "urn:ex/connection-to-room-303-304-306"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-523-discharge-air-flow-setpoint",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-525-hot-water-in"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-536-reheat-coil-water-out",
+ "@id": "urn:ex/office-ahu-clg-coil-valve-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-536-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/office-ahu-chilled-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
- ]
- },
- {
- "@id": "urn:ex/room-202",
- "@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/room-202-hvac-domain"
+ "@id": "urn:ex/office-ahu-chilled-water-out"
}
]
},
{
- "@id": "urn:ex/vav-518-hot-water-out-connection",
+ "@id": "urn:ex/vav-504-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-504-damper"
+ }
+ ],
+ "http://data.ashrae.org/standard223#commandedByProperty": [
+ {
+ "@id": "urn:ex/vav-504-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-509-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-508-discharge-air-temp",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/vav-509-pipe-hot-water-return-before-valve"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
- ]
- },
- {
- "@id": "urn:ex/vav-532-hot-water-in-connection",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-526-hot-water-in",
+ "@id": "urn:ex/vav-502-damper-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-526-hot-water-in-connection"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-502-air-in"
}
]
},
{
- "@id": "urn:ex/vav-509-discharge-air-flow-setpoint",
+ "@id": "urn:ex/vav-508-reheat-coil-valve-position",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/room-103-out",
+ "@id": "urn:ex/vav-523-air-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -27758,318 +27943,304 @@
]
},
{
- "@id": "urn:ex/vav-534-air-out",
+ "@id": "urn:ex/vav-517-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/connection-to-room-314"
- }
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-517-reheat-coil-valve"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-534-discharge-air-flow"
- },
- {
- "@id": "urn:ex/vav-534-discharge-air-flow-setpoint"
- },
- {
- "@id": "urn:ex/vav-534-discharge-air-temp"
- },
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/vav-534-discharge-air-temp-setpoint"
+ "@id": "urn:ex/vav-517-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/",
- "@type": [
- "http://www.w3.org/2002/07/owl#Ontology"
- ]
- },
- {
- "@id": "urn:ex/vav-525-hot-water-out",
+ "@id": "urn:ex/vav-504-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-525-hot-water-out-connection"
+ "@id": "urn:ex/vav-504-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
- ]
- },
- {
- "@id": "urn:ex/zone-211-occupancy-sensor",
- "@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:ex/room-211-hvac-domain"
- }
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/zone-211-occupancy"
+ "@id": "urn:ex/vav-504-hot-water-in"
}
]
},
{
- "@id": "urn:ex/zone-204-205",
+ "@id": "urn:ex/vav-513-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
- ],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/room-204-hvac-domain"
- },
- {
- "@id": "urn:ex/room-205-hvac-domain"
- }
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "urn:ex/vav-513-air-in"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/zone-204-205-cooling-setpoint"
- },
- {
- "@id": "urn:ex/zone-204-205-heating-setpoint"
- },
- {
- "@id": "urn:ex/zone-204-205-occupancy"
- },
- {
- "@id": "urn:ex/zone-204-205-occupancy-override"
- },
- {
- "@id": "urn:ex/zone-204-205-temp"
- },
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/zone-204-205-window-switch-on-off"
+ "@id": "urn:ex/vav-513-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/zone-109-cooling-setpoint",
+ "@id": "urn:ex/zone-207-window-switch-on-off",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/room-104-hvac-domain",
+ "@id": "urn:ex/vav-531-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-104-in"
- },
- {
- "@id": "urn:ex/room-104-out"
+ "@id": "urn:ex/vav-531-pipe-hot-water-return-before-valve"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/office-ahu-connection-to-vavs",
+ "@id": "urn:ex/vav-538-hot-water-out-connection",
"@type": [
"http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-528-damper-out",
+ "@id": "urn:ex/vav-532-colder-supply-air-requests",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-528-duct-after-damper"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/room-108",
+ "@type": [
+ "http://data.ashrae.org/standard223#PhysicalSpace"
+ ],
+ "http://data.ashrae.org/standard223#encloses": [
+ {
+ "@id": "urn:ex/room-108-hvac-domain"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-529-duct-after-damper",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-513-damper-actuator",
+ "@type": [
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/vav-528-colder-supply-air-requests"
- },
+ "@id": "urn:ex/vav-513-damper"
+ }
+ ],
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/vav-528-cooling-pid-output"
+ "@id": "urn:ex/vav-513-damper-command"
}
]
},
{
- "@id": "urn:ex/zone-302-occupancy",
+ "@id": "urn:ex/zone-303-304-306-temp",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-521-air-in",
+ "@id": "urn:ex/office-ahu-supply-duct-static-pressure-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/IN_H2O"
}
]
},
{
- "@id": "urn:ex/vav-529-discharge-air-flow-sensor",
+ "@id": "urn:ex/vav-535-discharge-air-flow-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-529-air-in"
+ "@id": "urn:ex/vav-535-air-in"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-529-discharge-air-flow"
+ "@id": "urn:ex/vav-535-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/vav-519-cooling-pid-output",
+ "@id": "urn:ex/vav-506-discharge-air-flow",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
+ "http://data.ashrae.org/standard223#hasAspect": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
+ ],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/room-311",
+ "@id": "urn:ex/vav-512-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-311-hvac-domain"
+ "@id": "urn:ex/vav-512-reheat-coil-valve-in"
+ },
+ {
+ "@id": "urn:ex/vav-512-reheat-coil-valve-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-512-reheat-coil-valve-command"
+ },
+ {
+ "@id": "urn:ex/vav-512-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-521-reheat-coil",
+ "@id": "urn:ex/vav-523-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-521-reheat-coil-air-in"
- },
- {
- "@id": "urn:ex/vav-521-reheat-coil-air-out"
- },
- {
- "@id": "urn:ex/vav-521-reheat-coil-water-in"
- },
- {
- "@id": "urn:ex/vav-521-reheat-coil-water-out"
+ "@id": "urn:ex/vav-523-pipe-hot-water-return-before-valve"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-527-reheat-coil",
+ "@id": "urn:ex/vav-502-air-in",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-527-reheat-coil-air-in"
- },
- {
- "@id": "urn:ex/vav-527-reheat-coil-air-out"
- },
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-527-reheat-coil-water-in"
- },
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-305-heating-setpoint",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-527-reheat-coil-water-out"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-515-reheat-coil-valve",
+ "@id": "urn:ex/vav-527-reheat-coil-valve",
"@type": [
"http://data.ashrae.org/standard223#Valve",
"http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-515-reheat-coil-valve-in"
+ "@id": "urn:ex/vav-527-reheat-coil-valve-in"
},
{
- "@id": "urn:ex/vav-515-reheat-coil-valve-out"
+ "@id": "urn:ex/vav-527-reheat-coil-valve-out"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -28079,15 +28250,15 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-515-reheat-coil-valve-command"
+ "@id": "urn:ex/vav-527-reheat-coil-valve-command"
},
{
- "@id": "urn:ex/vav-515-reheat-coil-valve-position"
+ "@id": "urn:ex/vav-527-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-509-hot-water-in-connection",
+ "@id": "urn:ex/vav-536-hot-water-in-connection",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Pipe"
@@ -28099,105 +28270,132 @@
]
},
{
- "@id": "urn:ex/room-215-out",
+ "@id": "urn:ex/office-ahu-ea-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/office-ahu-ea-damper"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/office-ahu-ea-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-528-reheat-coil-valve-actuator",
+ "@id": "urn:ex/room-115-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-528-reheat-coil-valve"
+ "@id": "urn:ex/room-115-in"
+ },
+ {
+ "@id": "urn:ex/room-115-out"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:ex/vav-528-reheat-coil-valve-command"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-517-reheat-coil",
+ "@id": "urn:ex/vav-520-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-517-reheat-coil-air-in"
- },
+ "@id": "urn:ex/vav-520-hot-water-in-connection"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-517-reheat-coil-air-out"
- },
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-517-reheat-coil-water-in"
- },
+ "@id": "urn:ex/vav-520-hot-water-in"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-214-heating-setpoint",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-517-reheat-coil-water-out"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/office-ahu-ma-temp",
+ "@id": "urn:ex/vav-506-cooling-pid-output",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-509-reheat-coil-water-in",
+ "@id": "urn:ex/room-211-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-509-hot-water-in-connection"
+ "@id": "urn:ex/room-211-in"
+ },
+ {
+ "@id": "urn:ex/room-211-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-212-occupancy",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-509-hot-water-in"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
]
},
{
- "@id": "urn:ex/vav-529-duct-after-damper",
+ "@id": "urn:ex/room-307-out",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -28206,7 +28404,7 @@
]
},
{
- "@id": "urn:ex/vav-533-damper-position",
+ "@id": "urn:ex/vav-519-reheat-coil-valve-position",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -28222,7 +28420,19 @@
]
},
{
- "@id": "urn:ex/vav-505-damper-in",
+ "@id": "urn:ex/connection-to-room-312",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-527-damper-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -28238,36 +28448,52 @@
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-505-air-in"
+ "@id": "urn:ex/vav-527-air-in"
}
]
},
{
- "@id": "urn:ex/vav-538-damper-out",
+ "@id": "urn:ex/vav-539-pipe-hot-water-return-before-valve",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-538-duct-after-damper"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-531-discharge-air-temp-sensor",
+ "@type": [
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-531-air-out"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-538-colder-supply-air-requests"
- },
+ "@id": "urn:ex/vav-531-discharge-air-temp"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-525-duct-after-damper",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-538-cooling-pid-output"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-527-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/vav-538-pipe-hot-water-return-before-valve",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Pipe"
@@ -28279,10 +28505,25 @@
]
},
{
- "@id": "urn:ex/connection-to-room-206",
+ "@id": "urn:ex/vav-540-colder-supply-air-requests",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ {
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/room-301-out",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -28291,338 +28532,296 @@
]
},
{
- "@id": "urn:ex/zone-214",
+ "@id": "urn:ex/room-309-in",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-214-hvac-domain"
+ "@id": "urn:ex/connection-to-room-309-310"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-508-reheat-coil",
+ "@type": [
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/zone-214-cooling-setpoint"
- },
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/zone-214-heating-setpoint"
+ "@id": "urn:ex/vav-508-reheat-coil-air-in"
},
{
- "@id": "urn:ex/zone-214-occupancy"
+ "@id": "urn:ex/vav-508-reheat-coil-air-out"
},
{
- "@id": "urn:ex/zone-214-occupancy-override"
+ "@id": "urn:ex/vav-508-reheat-coil-water-in"
},
{
- "@id": "urn:ex/zone-214-temp"
- },
+ "@id": "urn:ex/vav-508-reheat-coil-water-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "urn:ex/zone-214-window-switch-on-off"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/vav-533-heating-pid-output",
+ "@id": "urn:ex/vav-537-discharge-air-flow-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-532-damper-command",
+ "@id": "urn:ex/vav-522-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-522-hot-water-in-connection"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
- ]
- },
- {
- "@id": "urn:ex/vav-519-hot-water-out-connection",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-522-hot-water-in"
}
]
},
{
- "@id": "urn:ex/zone-113",
+ "@id": "urn:ex/vav-524-hot-water-in",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-113-hvac-domain"
+ "@id": "urn:ex/vav-524-hot-water-in-connection"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-314-occupancy-override",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/zone-113-cooling-setpoint"
- },
- {
- "@id": "urn:ex/zone-113-heating-setpoint"
- },
- {
- "@id": "urn:ex/zone-113-occupancy"
- },
- {
- "@id": "urn:ex/zone-113-occupancy-override"
- },
- {
- "@id": "urn:ex/zone-113-temp"
- },
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/zone-113-window-switch-on-off"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
]
},
{
- "@id": "urn:ex/vav-515-discharge-air-flow-sensor",
+ "@id": "urn:ex/vav-525-reheat-coil-valve-position",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-515-air-in"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-515-discharge-air-flow"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-506-reheat-coil-valve",
+ "@id": "urn:ex/zone-312-cooling-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-506-reheat-coil-valve-in"
- },
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-506-reheat-coil-valve-out"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-510-more-heat-requests",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-506-reheat-coil-valve-command"
- },
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-506-reheat-coil-valve-position"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-512-air-out",
+ "@id": "urn:ex/room-103-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-118"
+ "@id": "urn:ex/connection-to-room-103"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-512-discharge-air-flow"
- },
- {
- "@id": "urn:ex/vav-512-discharge-air-flow-setpoint"
- },
- {
- "@id": "urn:ex/vav-512-discharge-air-temp"
- },
- {
- "@id": "urn:ex/vav-512-discharge-air-temp-setpoint"
- }
]
},
{
- "@id": "urn:ex/vav-502-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/vav-532-duct-after-damper",
"@type": [
"http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-501-discharge-air-temp-sensor",
+ "@id": "urn:ex/office-ahu-oa-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-501-air-out"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-501-discharge-air-temp"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-528-hot-water-out-connection",
+ "@id": "urn:ex/vav-523-discharge-air-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/office-ahu-supply-duct-static-pressure",
+ "@id": "urn:ex/vav-524-heating-pid-output",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Supply"
- }
- ],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/IN_H2O"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-540-damper-in",
+ "@id": "urn:ex/vav-509-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/office-ahu-connection-to-vavs"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-540-air-in"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/zone-116-117-occupancy-override",
+ "@id": "urn:ex/room-305",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "urn:ex/room-305-hvac-domain"
}
]
},
{
- "@id": "urn:ex/vav-529-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-535-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-529-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-535-air-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-535-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/vav-523-air-out",
+ "@id": "urn:ex/vav-501-discharge-air-flow",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/connection-to-room-206"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-523-discharge-air-flow"
- },
- {
- "@id": "urn:ex/vav-523-discharge-air-flow-setpoint"
- },
- {
- "@id": "urn:ex/vav-523-discharge-air-temp"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-523-discharge-air-temp-setpoint"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/zone-109-heating-setpoint",
+ "@id": "urn:ex/vav-511-discharge-air-temp-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -28638,117 +28837,127 @@
]
},
{
- "@id": "urn:ex/zone-206-heating-setpoint",
+ "@id": "urn:ex/vav-534-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-534-duct-after-damper"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/vav-507-pipe-hot-water-return-before-valve",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-534-colder-supply-air-requests"
+ },
+ {
+ "@id": "urn:ex/vav-534-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/vav-532",
+ "@id": "urn:ex/vav-518-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-532-air-in"
- },
- {
- "@id": "urn:ex/vav-532-air-out"
- },
- {
- "@id": "urn:ex/vav-532-hot-water-in"
+ "@id": "urn:ex/vav-518-reheat-coil-valve-in"
},
{
- "@id": "urn:ex/vav-532-hot-water-out"
+ "@id": "urn:ex/vav-518-reheat-coil-valve-out"
}
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-532-damper"
- },
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-532-reheat-coil"
+ "@id": "urn:ex/vav-518-reheat-coil-valve-command"
},
{
- "@id": "urn:ex/vav-532-reheat-coil-valve"
+ "@id": "urn:ex/vav-518-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-517-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/vav-521-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-521-air-in"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:ex/vav-521-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/office-ahu-clg-coil-valve-in",
+ "@id": "urn:ex/vav-501-air-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-pipe-chilled-water-return-before-valve"
+ "@id": "urn:ex/connection-to-room-102"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-501-discharge-air-flow"
+ },
+ {
+ "@id": "urn:ex/vav-501-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-501-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-501-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/vav-517-damper-command",
+ "@id": "urn:ex/vav-516-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-516-air-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/vav-516-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/vav-509-reheat-coil-water-out",
+ "@id": "urn:ex/vav-508-reheat-coil-water-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-509-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-508-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -28758,96 +28967,78 @@
]
},
{
- "@id": "urn:ex/vav-537-discharge-air-temp",
+ "@id": "urn:ex/office-ahu-ra-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/office-ahu-ra-in"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/office-ahu-ra-flow"
}
]
},
{
- "@id": "urn:ex/zone-215-temp",
+ "@id": "urn:ex/vav-528-discharge-air-flow",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
+ "http://data.ashrae.org/standard223#hasAspect": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
+ ],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-518-air-out",
+ "@id": "urn:ex/room-115-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-202"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-518-discharge-air-flow"
- },
- {
- "@id": "urn:ex/vav-518-discharge-air-flow-setpoint"
- },
- {
- "@id": "urn:ex/vav-518-discharge-air-temp"
- },
- {
- "@id": "urn:ex/vav-518-discharge-air-temp-setpoint"
- }
]
},
{
- "@id": "urn:ex/vav-536-reheat-coil-valve-command",
+ "@id": "urn:ex/vav-512-hot-water-in-connection",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-522-reheat-coil-air-in",
+ "@id": "urn:ex/room-115-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-522-duct-after-damper"
+ "@id": "urn:ex/connection-to-room-115"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -28857,58 +29048,79 @@
]
},
{
- "@id": "urn:ex/zone-207",
+ "@id": "urn:ex/vav-505-discharge-air-flow",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/room-207-hvac-domain"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/zone-207-cooling-setpoint"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/zone-207-heating-setpoint"
- },
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/room-103",
+ "@type": [
+ "http://data.ashrae.org/standard223#PhysicalSpace"
+ ],
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "urn:ex/zone-207-occupancy"
- },
+ "@id": "urn:ex/room-103-hvac-domain"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-506-discharge-air-temp",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/zone-207-occupancy-override"
- },
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/zone-207-temp"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/zone-207-window-switch-on-off"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/zone-314-window-switch-on-off",
+ "@id": "urn:ex/vav-540-hot-water-out-connection",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-506-hot-water-out-connection",
+ "@id": "urn:ex/vav-524-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-524-pipe-hot-water-return-before-valve"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -28917,227 +29129,264 @@
]
},
{
- "@id": "urn:ex/vav-526-more-heat-requests",
+ "@id": "urn:ex/vav-538-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/vav-538-pipe-hot-water-return-before-valve"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-523-colder-supply-air-requests",
+ "@id": "urn:ex/zone-105-window-switch-on-off",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/vav-508-hot-water-out-connection",
+ "@id": "urn:ex/zone-313-occupancy-override",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
]
},
{
- "@id": "urn:ex/zone-215-temp-sensor",
+ "@id": "urn:ex/vav-515-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-215-hvac-domain"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-215-temp"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-515-air-in"
}
]
},
{
- "@id": "urn:ex/vav-515-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-539-reheat-coil-water-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-515-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-539-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-539-hot-water-in"
+ }
]
},
{
- "@id": "urn:ex/vav-528-heating-pid-output",
+ "@id": "urn:ex/vav-531-discharge-air-temp",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
+ "http://data.ashrae.org/standard223#hasAspect": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
+ ],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-519-air-out",
+ "@id": "urn:ex/vav-506-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/connection-to-room-204-205"
+ "@id": "urn:ex/vav-506-reheat-coil-valve"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-506-reheat-coil-valve-command"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-513-discharge-air-flow",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/vav-519-discharge-air-flow"
- },
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-519-discharge-air-flow-setpoint"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-519-discharge-air-temp"
- },
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-524-pipe-hot-water-return-before-valve",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-519-discharge-air-temp-setpoint"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/office-ahu-colder-supply-air-requests",
+ "@id": "urn:ex/vav-535-cooling-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ }
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-521-discharge-air-temp-sensor",
+ "@id": "urn:ex/zone-101-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-521-air-out"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-521-discharge-air-temp"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-502-reheat-coil-water-in",
+ "@id": "urn:ex/vav-540-discharge-air-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-502-hot-water-in-connection"
- }
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-502-hot-water-in"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/zone-203-occupancy-override",
+ "@id": "urn:ex/vav-518-discharge-air-temp",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
- ]
- },
- {
- "@id": "urn:ex/vav-511-discharge-air-temp-sensor",
- "@type": [
- "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-511-air-out"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-511-discharge-air-temp"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-508-heating-pid-output",
+ "@id": "urn:ex/vav-509-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/vav-509-hot-water-out-connection"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/zone-102-occupancy",
+ "@id": "urn:ex/vav-514-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "urn:ex/vav-514-pipe-hot-water-return-before-valve"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-511-reheat-coil-water-out",
+ "@id": "urn:ex/vav-517-hot-water-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-511-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-517-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -29147,153 +29396,135 @@
]
},
{
- "@id": "urn:ex/vav-538",
+ "@id": "urn:ex/vav-532",
"@type": [
"http://data.ashrae.org/standard223#SingleDuctTerminal",
"http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-538-air-in"
+ "@id": "urn:ex/vav-532-air-in"
},
{
- "@id": "urn:ex/vav-538-air-out"
+ "@id": "urn:ex/vav-532-air-out"
},
{
- "@id": "urn:ex/vav-538-hot-water-in"
+ "@id": "urn:ex/vav-532-hot-water-in"
},
{
- "@id": "urn:ex/vav-538-hot-water-out"
+ "@id": "urn:ex/vav-532-hot-water-out"
}
],
"http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/vav-538-damper"
+ "@id": "urn:ex/vav-532-damper"
},
{
- "@id": "urn:ex/vav-538-reheat-coil"
+ "@id": "urn:ex/vav-532-reheat-coil"
},
{
- "@id": "urn:ex/vav-538-reheat-coil-valve"
+ "@id": "urn:ex/vav-532-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/vav-514-heating-pid-output",
+ "@id": "urn:ex/zone-110-temp",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-516-damper-in",
+ "@id": "urn:ex/vav-528-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-528-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-516-air-in"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-534-reheat-coil-air-out",
+ "@id": "urn:ex/vav-525-reheat-coil-air-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-314"
+ "@id": "urn:ex/vav-525-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-534-heating-pid-output"
- },
- {
- "@id": "urn:ex/vav-534-more-heat-requests"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-534-air-out"
- }
]
},
{
- "@id": "urn:ex/zone-301-temp-sensor",
+ "@id": "urn:ex/vav-506-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-301-hvac-domain"
+ "@id": "urn:ex/vav-506-pipe-hot-water-return-before-valve"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-301-temp"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-521-discharge-air-flow-sensor",
+ "@id": "urn:ex/vav-525-reheat-coil-valve-command",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-521-air-in"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-521-discharge-air-flow"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-514-hot-water-in",
+ "@id": "urn:ex/zone-104-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-514-hot-water-in-connection"
+ "@id": "urn:ex/room-104-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/zone-104-temp"
}
]
},
{
- "@id": "urn:ex/vav-514-more-heat-requests",
+ "@id": "urn:ex/vav-531-more-heat-requests",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
@@ -29304,279 +29535,259 @@
]
},
{
- "@id": "urn:ex/room-314-out",
+ "@id": "urn:ex/vav-512-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/vav-512-reheat-coil-valve"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-512-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/vav-517-reheat-coil-valve",
+ "@id": "urn:ex/vav-522-heating-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-517-reheat-coil-valve-in"
- },
- {
- "@id": "urn:ex/vav-517-reheat-coil-valve-out"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-517-reheat-coil-valve-command"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-517-reheat-coil-valve-position"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/room-205",
+ "@id": "urn:ex/vav-525-discharge-air-flow",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/room-205-hvac-domain"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
- ]
- },
- {
- "@id": "urn:ex/vav-527-damper-command",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-510-hot-water-in",
+ "@id": "urn:ex/vav-503-discharge-air-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-510-hot-water-in-connection"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/zone-210",
+ "@id": "urn:ex/office-ahu-colder-supply-air-requests",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
- ],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/room-210-hvac-domain"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-540",
+ "@type": [
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/zone-210-cooling-setpoint"
+ "@id": "urn:ex/vav-540-air-in"
},
{
- "@id": "urn:ex/zone-210-heating-setpoint"
+ "@id": "urn:ex/vav-540-air-out"
},
{
- "@id": "urn:ex/zone-210-occupancy"
+ "@id": "urn:ex/vav-540-hot-water-in"
},
{
- "@id": "urn:ex/zone-210-occupancy-override"
+ "@id": "urn:ex/vav-540-hot-water-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#contains": [
+ {
+ "@id": "urn:ex/vav-540-damper"
},
{
- "@id": "urn:ex/zone-210-temp"
+ "@id": "urn:ex/vav-540-reheat-coil"
},
{
- "@id": "urn:ex/zone-210-window-switch-on-off"
+ "@id": "urn:ex/vav-540-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/vav-502-damper-command",
+ "@id": "urn:ex/zone-108-occupancy",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
]
},
{
- "@id": "urn:ex/vav-506-cooling-pid-output",
+ "@id": "urn:ex/office-ahu-ra-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/office-ahu-ra-flow"
+ },
+ {
+ "@id": "urn:ex/office-ahu-ra-temp"
}
]
},
{
- "@id": "urn:ex/vav-539-discharge-air-flow-sensor",
+ "@id": "urn:ex/zone-307-308-occupancy-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-539-air-in"
+ "@id": "urn:ex/room-307-hvac-domain"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-539-discharge-air-flow"
+ "@id": "urn:ex/zone-307-308-occupancy"
}
]
},
{
- "@id": "urn:ex/vav-524",
+ "@id": "urn:ex/vav-514-pipe-hot-water-return-before-valve",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-524-air-in"
- },
- {
- "@id": "urn:ex/vav-524-air-out"
- },
- {
- "@id": "urn:ex/vav-524-hot-water-in"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-524-hot-water-out"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-528-reheat-coil-valve-position",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/vav-524-damper"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-524-reheat-coil"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-524-reheat-coil-valve"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-519-reheat-coil-air-out",
+ "@id": "urn:ex/vav-501-duct-after-damper",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/connection-to-room-204-205"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-210-cooling-setpoint",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-519-heating-pid-output"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-519-more-heat-requests"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-519-air-out"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/connection-to-room-103",
+ "@id": "urn:ex/zone-201-occupancy-override",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
]
},
{
- "@id": "urn:ex/vav-531-reheat-coil-valve-out",
+ "@id": "urn:ex/vav-533-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-531-hot-water-out-connection"
- }
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-533-damper"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/vav-531-hot-water-out"
+ "@id": "urn:ex/vav-533-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-520-air-out",
+ "@id": "urn:ex/vav-520-damper-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-207"
+ "@id": "urn:ex/vav-520-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -29586,99 +29797,104 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-520-discharge-air-flow"
- },
- {
- "@id": "urn:ex/vav-520-discharge-air-flow-setpoint"
- },
- {
- "@id": "urn:ex/vav-520-discharge-air-temp"
+ "@id": "urn:ex/vav-520-colder-supply-air-requests"
},
{
- "@id": "urn:ex/vav-520-discharge-air-temp-setpoint"
+ "@id": "urn:ex/vav-520-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/office-ahu-ra-fan-start-status",
+ "@id": "urn:ex/vav-525-pipe-hot-water-return-before-valve",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-529-hot-water-in-connection",
+ "@id": "urn:ex/vav-511-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-511-duct-after-damper"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-511-colder-supply-air-requests"
+ },
+ {
+ "@id": "urn:ex/vav-511-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/zone-102-temp",
+ "@id": "urn:ex/vav-515-discharge-air-flow-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/office-ahu-sa-out",
+ "@id": "urn:ex/vav-513-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-513-air-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-513-discharge-air-temp"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-521-discharge-air-flow",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/office-ahu-colder-supply-air-requests"
- },
- {
- "@id": "urn:ex/office-ahu-increased-air-pressure-requests"
- },
- {
- "@id": "urn:ex/office-ahu-sa-temp"
- },
- {
- "@id": "urn:ex/office-ahu-sa-temp-setpoint"
- },
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/office-ahu-supply-duct-static-pressure"
- },
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/office-ahu-supply-duct-static-pressure-setpoint"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/office-ahu-warmer-supply-air-requests"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-522-more-heat-requests",
+ "@id": "urn:ex/vav-538-more-heat-requests",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
@@ -29689,247 +29905,253 @@
]
},
{
- "@id": "urn:ex/vav-503-discharge-air-flow-sensor",
+ "@id": "urn:ex/zone-208-209-temp",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-503-air-in"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-503-discharge-air-flow"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-540-reheat-coil-water-out",
+ "@id": "urn:ex/vav-536-reheat-coil-valve-position",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-540-pipe-hot-water-return-before-valve"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-519-damper-in",
+ "@id": "urn:ex/vav-501-reheat-coil-valve-command",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/office-ahu-connection-to-vavs"
- }
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-519-air-in"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-529-heating-pid-output",
+ "@id": "urn:ex/vav-510-reheat-coil-valve-position",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-505-discharge-air-temp-setpoint",
+ "@id": "urn:ex/vav-540-discharge-air-flow",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasAspect": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/connection-to-room-212",
+ "@id": "urn:ex/zone-110-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-537-hot-water-in",
+ "@id": "urn:ex/vav-534-damper",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-537-hot-water-in-connection"
+ "@id": "urn:ex/vav-534-damper-in"
+ },
+ {
+ "@id": "urn:ex/vav-534-damper-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-534-damper-command"
+ },
+ {
+ "@id": "urn:ex/vav-534-damper-position"
}
]
},
{
- "@id": "urn:ex/room-111-hvac-domain",
+ "@id": "urn:ex/vav-513-discharge-air-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/room-111-in"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-111-out"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-532-reheat-coil-valve",
+ "@id": "urn:ex/vav-509-air-in",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-532-reheat-coil-valve-in"
- },
- {
- "@id": "urn:ex/vav-532-reheat-coil-valve-out"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-532-reheat-coil-valve-command"
- },
- {
- "@id": "urn:ex/vav-532-reheat-coil-valve-position"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-503-hot-water-out",
+ "@id": "urn:ex/office-ahu-ea-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-503-hot-water-out-connection"
+ "@id": "urn:ex/office-ahu-ea-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-503-heating-pid-output",
+ "@id": "urn:ex/vav-523-reheat-coil-air-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/connection-to-room-206"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/zone-102-occupancy-override",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "urn:ex/vav-523-heating-pid-output"
+ },
+ {
+ "@id": "urn:ex/vav-523-more-heat-requests"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-523-air-out"
}
]
},
{
- "@id": "urn:ex/vav-523-discharge-air-flow",
+ "@id": "urn:ex/vav-524-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:ex/vav-524-air-in"
}
]
},
{
- "@id": "urn:ex/vav-532-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-501-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-532-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-501-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-501-colder-supply-air-requests"
+ },
+ {
+ "@id": "urn:ex/vav-501-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/zone-311-cooling-setpoint",
+ "@id": "urn:ex/zone-212-cooling-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -29945,227 +30167,283 @@
]
},
{
- "@id": "urn:ex/vav-522-hot-water-out",
+ "@id": "urn:ex/vav-526",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-522-hot-water-out-connection"
+ "@id": "urn:ex/vav-526-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-526-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-526-hot-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-526-hot-water-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-526-damper"
+ },
+ {
+ "@id": "urn:ex/vav-526-reheat-coil"
+ },
+ {
+ "@id": "urn:ex/vav-526-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/vav-536-damper-actuator",
+ "@id": "urn:ex/vav-537-air-out",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-536-damper"
+ "@id": "urn:ex/connection-to-room-312"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-536-damper-command"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-537-discharge-air-flow"
+ },
+ {
+ "@id": "urn:ex/vav-537-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-537-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-537-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/vav-510-discharge-air-flow-setpoint",
+ "@id": "urn:ex/vav-512-hot-water-out-connection",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-528-air-out",
+ "@id": "urn:ex/vav-518-air-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-302"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/room-215-hvac-domain",
+ "@type": [
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-528-discharge-air-flow"
- },
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-528-discharge-air-flow-setpoint"
+ "@id": "urn:ex/room-215-in"
},
{
- "@id": "urn:ex/vav-528-discharge-air-temp"
- },
+ "@id": "urn:ex/room-215-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:ex/vav-528-discharge-air-temp-setpoint"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-513-hot-water-out",
+ "@id": "urn:ex/vav-503-reheat-coil-valve-command",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-513-hot-water-out-connection"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-536-reheat-coil-valve-actuator",
+ "@id": "urn:ex/vav-512-damper-actuator",
"@type": [
"http://data.ashrae.org/standard223#Actuator"
],
"http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/vav-536-reheat-coil-valve"
+ "@id": "urn:ex/vav-512-damper"
}
],
"http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/vav-536-reheat-coil-valve-command"
+ "@id": "urn:ex/vav-512-damper-command"
}
]
},
{
- "@id": "urn:ex/room-116-out",
+ "@id": "urn:ex/connection-to-room-313",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-526-colder-supply-air-requests",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-529-reheat-coil-valve-actuator",
+ "@id": "urn:ex/vav-503-colder-supply-air-requests",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-529-reheat-coil-valve"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-510-colder-supply-air-requests",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-529-reheat-coil-valve-command"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-502-reheat-coil-valve-position",
+ "@id": "urn:ex/vav-538-heating-pid-output",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/zone-302-temp-sensor",
+ "@id": "urn:ex/vav-535-reheat-coil-valve-command",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-302-hvac-domain"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/zone-302-temp"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/room-113-in",
+ "@id": "urn:ex/vav-534-cooling-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/connection-to-room-113"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/zone-109-occupancy",
+ "@id": "urn:ex/vav-539-colder-supply-air-requests",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-540-damper-position",
+ "@id": "urn:ex/vav-516-colder-supply-air-requests",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-522-pipe-hot-water-return-before-valve",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/zone-204-205-temp",
+ "@id": "urn:ex/vav-501-discharge-air-temp",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
+ "http://data.ashrae.org/standard223#hasAspect": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
+ ],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
"@id": "http://qudt.org/vocab/quantitykind/Temperature"
@@ -30178,13 +30456,35 @@
]
},
{
- "@id": "urn:ex/vav-509-reheat-coil-air-out",
+ "@id": "urn:ex/room-203",
+ "@type": [
+ "http://data.ashrae.org/standard223#PhysicalSpace"
+ ],
+ "http://data.ashrae.org/standard223#encloses": [
+ {
+ "@id": "urn:ex/room-203-hvac-domain"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-303-304-306-window-switch-on-off",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ {
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-540-damper-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-113"
+ "@id": "urn:ex/vav-540-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -30194,305 +30494,340 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-509-heating-pid-output"
+ "@id": "urn:ex/vav-540-colder-supply-air-requests"
},
{
- "@id": "urn:ex/vav-509-more-heat-requests"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-509-air-out"
+ "@id": "urn:ex/vav-540-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/vav-510-discharge-air-flow-sensor",
+ "@id": "urn:ex/vav-514-cooling-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-510-air-in"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-510-discharge-air-flow"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-537-damper",
+ "@id": "urn:ex/zone-212",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/vav-537-damper-in"
- },
+ "@id": "urn:ex/room-212-hvac-domain"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:ex/vav-537-damper-out"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-537-damper-command"
+ "@id": "urn:ex/zone-212-cooling-setpoint"
},
{
- "@id": "urn:ex/vav-537-damper-position"
+ "@id": "urn:ex/zone-212-heating-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-212-occupancy"
+ },
+ {
+ "@id": "urn:ex/zone-212-occupancy-override"
+ },
+ {
+ "@id": "urn:ex/zone-212-temp"
+ },
+ {
+ "@id": "urn:ex/zone-212-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/zone-210-window-switch-on-off",
+ "@id": "urn:ex/vav-505",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "urn:ex/vav-505-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-505-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-505-hot-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-505-hot-water-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#contains": [
+ {
+ "@id": "urn:ex/vav-505-damper"
+ },
+ {
+ "@id": "urn:ex/vav-505-reheat-coil"
+ },
+ {
+ "@id": "urn:ex/vav-505-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/connection-to-room-106-107",
+ "@id": "urn:ex/vav-526-reheat-coil-air-out",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/connection-to-room-212"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/office-ahu-oa-damper-command",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-526-heating-pid-output"
+ },
+ {
+ "@id": "urn:ex/vav-526-more-heat-requests"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/vav-526-air-out"
}
]
},
{
- "@id": "urn:ex/vav-505-damper-command",
+ "@id": "urn:ex/vav-525-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-525-reheat-coil-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-525-reheat-coil-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-525-reheat-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-525-reheat-coil-water-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/vav-535-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/vav-504-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-504-air-in"
}
]
},
{
- "@id": "urn:ex/vav-527-reheat-coil-valve-position",
+ "@id": "urn:ex/zone-111-occupancy-override",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
]
},
{
- "@id": "urn:ex/vav-521-reheat-coil-valve",
+ "@id": "urn:ex/vav-535-damper",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-521-reheat-coil-valve-in"
+ "@id": "urn:ex/vav-535-damper-in"
},
{
- "@id": "urn:ex/vav-521-reheat-coil-valve-out"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "urn:ex/vav-535-damper-out"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-521-reheat-coil-valve-command"
+ "@id": "urn:ex/vav-535-damper-command"
},
{
- "@id": "urn:ex/vav-521-reheat-coil-valve-position"
+ "@id": "urn:ex/vav-535-damper-position"
}
]
},
{
- "@id": "urn:ex/vav-501-more-heat-requests",
+ "@id": "urn:ex/vav-509-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/vav-509-air-in"
}
- ]
- },
- {
- "@id": "urn:ex/vav-539-hot-water-in-connection",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-509-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/vav-509-discharge-air-temp-sensor",
+ "@id": "urn:ex/zone-206-temp-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-509-air-out"
+ "@id": "urn:ex/room-206-hvac-domain"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-509-discharge-air-temp"
+ "@id": "urn:ex/zone-206-temp"
}
]
},
{
- "@id": "urn:ex/vav-515-reheat-coil-air-in",
+ "@id": "urn:ex/zone-212-occupancy-sensor",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-515-duct-after-damper"
+ "@id": "urn:ex/room-212-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/zone-212-occupancy"
}
]
},
{
- "@id": "urn:ex/vav-522-air-in",
+ "@id": "urn:ex/vav-528-discharge-air-temp",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-534-damper-actuator",
+ "@id": "urn:ex/vav-502-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-534-damper"
+ "@id": "urn:ex/vav-502-hot-water-out-connection"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-534-damper-command"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/office-ahu-clg-coil-air-in",
+ "@id": "urn:ex/vav-535-hot-water-out-connection",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/office-ahu-duct-after-htg-coil"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-527-reheat-coil-water-out",
+ "@id": "urn:ex/office-ahu-htg-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-527-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/office-ahu-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/office-ahu-hot-water-in"
+ }
]
},
{
- "@id": "urn:ex/vav-504-cooling-pid-output",
+ "@id": "urn:ex/vav-508-hot-water-out-connection",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-512-discharge-air-flow-setpoint",
+ "@id": "urn:ex/vav-511-discharge-air-flow-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -30508,150 +30843,98 @@
]
},
{
- "@id": "urn:ex/vav-533-damper",
+ "@id": "urn:ex/room-302-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-533-damper-in"
- },
- {
- "@id": "urn:ex/vav-533-damper-out"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-533-damper-command"
+ "@id": "urn:ex/room-302-in"
},
{
- "@id": "urn:ex/vav-533-damper-position"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-503-reheat-coil-water-out",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-503-pipe-hot-water-return-before-valve"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ]
- },
- {
- "@id": "urn:ex/zone-115-temp-sensor",
- "@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:ex/room-115-hvac-domain"
+ "@id": "urn:ex/room-302-out"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:ex/zone-115-temp"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-537-cooling-pid-output",
+ "@id": "urn:ex/vav-521-discharge-air-flow-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/office-ahu-ea-damper-in",
+ "@id": "urn:ex/vav-528-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-duct-after-ra-fan"
+ "@id": "urn:ex/vav-528-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/zone-305-occupancy",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
- }
- ]
- },
- {
- "@id": "urn:ex/zone-313-window-switch-on-off",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "@id": "urn:ex/vav-528-colder-supply-air-requests"
+ },
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "urn:ex/vav-528-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/vav-504-damper",
+ "@id": "urn:ex/vav-503",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-504-damper-in"
+ "@id": "urn:ex/vav-503-air-in"
},
{
- "@id": "urn:ex/vav-504-damper-out"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "@id": "urn:ex/vav-503-air-out"
+ },
{
- "@id": "urn:ex/vav-504-damper-command"
+ "@id": "urn:ex/vav-503-hot-water-in"
},
{
- "@id": "urn:ex/vav-504-damper-position"
+ "@id": "urn:ex/vav-503-hot-water-out"
}
- ]
- },
- {
- "@id": "urn:ex/zone-211-window-switch-on-off",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "urn:ex/vav-503-damper"
+ },
+ {
+ "@id": "urn:ex/vav-503-reheat-coil"
+ },
+ {
+ "@id": "urn:ex/vav-503-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/vav-537-hot-water-out-connection",
+ "@id": "urn:ex/vav-505-pipe-hot-water-return-before-valve",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Pipe"
@@ -30663,26 +30946,14 @@
]
},
{
- "@id": "urn:ex/office-ahu-supply-duct-static-pressure-sensor",
+ "@id": "urn:ex/room-206-in",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:ex/office-ahu-sa-out"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-supply-duct-static-pressure"
+ "@id": "urn:ex/connection-to-room-206"
}
- ]
- },
- {
- "@id": "urn:ex/connection-to-room-203",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -30691,103 +30962,92 @@
]
},
{
- "@id": "urn:ex/vav-537-reheat-coil-valve",
+ "@id": "urn:ex/vav-526-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-537-reheat-coil-valve-in"
- },
- {
- "@id": "urn:ex/vav-537-reheat-coil-valve-out"
+ "@id": "urn:ex/vav-526-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-537-reheat-coil-valve-command"
- },
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-537-reheat-coil-valve-position"
+ "@id": "urn:ex/vav-526-hot-water-in"
}
]
},
{
- "@id": "urn:ex/vav-531-damper-position",
+ "@id": "urn:ex/vav-519-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-519-air-in"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/vav-519-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/office-ahu-clg-coil-water-in",
+ "@id": "urn:ex/zone-302-occupancy-sensor",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/office-ahu-chilled-water-in-connection"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/office-ahu-colder-chilled-water-requests"
+ "@id": "urn:ex/room-302-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/office-ahu-chilled-water-in"
+ "@id": "urn:ex/zone-302-occupancy"
}
]
},
{
- "@id": "urn:ex/vav-523-reheat-coil",
+ "@id": "urn:ex/vav-513",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-523-reheat-coil-air-in"
+ "@id": "urn:ex/vav-513-air-in"
},
{
- "@id": "urn:ex/vav-523-reheat-coil-air-out"
+ "@id": "urn:ex/vav-513-air-out"
},
{
- "@id": "urn:ex/vav-523-reheat-coil-water-in"
+ "@id": "urn:ex/vav-513-hot-water-in"
},
{
- "@id": "urn:ex/vav-523-reheat-coil-water-out"
+ "@id": "urn:ex/vav-513-hot-water-out"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "urn:ex/vav-513-damper"
+ },
+ {
+ "@id": "urn:ex/vav-513-reheat-coil"
+ },
+ {
+ "@id": "urn:ex/vav-513-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/vav-516-reheat-coil-valve-position",
+ "@id": "urn:ex/vav-508-damper-position",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -30803,235 +31063,214 @@
]
},
{
- "@id": "urn:ex/zone-303-304-306-heating-setpoint",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
- {
- "@id": "http://qudt.org/vocab/unit/DEG_C"
- }
- ]
- },
- {
- "@id": "urn:ex/zone-116-117-occupancy-sensor",
+ "@id": "urn:ex/connection-to-room-301",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:ex/room-116-hvac-domain"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-116-117-occupancy"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-531-duct-after-damper",
+ "@id": "urn:ex/vav-533-hot-water-in-connection",
"@type": [
"http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-521-cooling-pid-output",
+ "@id": "urn:ex/vav-536-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/vav-536-pipe-hot-water-return-before-valve"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-523-discharge-air-temp-sensor",
+ "@id": "urn:ex/vav-505-damper-command",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-523-air-out"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-523-discharge-air-temp"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-508-hot-water-out",
+ "@id": "urn:ex/vav-507-damper",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-508-hot-water-out-connection"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:ex/vav-507-damper-in"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-507-damper-out"
}
- ]
- },
- {
- "@id": "urn:ex/vav-535-heating-pid-output",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "urn:ex/vav-507-damper-command"
+ },
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "urn:ex/vav-507-damper-position"
}
]
},
{
- "@id": "urn:ex/vav-536-damper-out",
+ "@id": "urn:ex/vav-537-hot-water-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-536-duct-after-damper"
+ "@id": "urn:ex/vav-537-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-208-209-window-switch-on-off",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-536-colder-supply-air-requests"
- },
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-536-cooling-pid-output"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/vav-509-reheat-coil-air-in",
+ "@id": "urn:ex/vav-501-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/vav-509-duct-after-damper"
+ "@id": "urn:ex/vav-501-reheat-coil-valve"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-501-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/vav-535-hot-water-out",
+ "@id": "urn:ex/office-ahu-ra-temp",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/vav-535-hot-water-out-connection"
+ "@id": "http://data.ashrae.org/standard223#Role-Return"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-525-reheat-coil-valve-actuator",
+ "@id": "urn:ex/vav-527-damper-actuator",
"@type": [
"http://data.ashrae.org/standard223#Actuator"
],
"http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/vav-525-reheat-coil-valve"
+ "@id": "urn:ex/vav-527-damper"
}
],
"http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/vav-525-reheat-coil-valve-command"
+ "@id": "urn:ex/vav-527-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-519-reheat-coil-air-in",
+ "@id": "urn:ex/vav-534-reheat-coil-valve-position",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-519-duct-after-damper"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-505-cooling-pid-output",
+ "@id": "urn:ex/vav-522-reheat-coil-valve-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/vav-522-hot-water-out-connection"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-522-hot-water-out"
}
]
},
{
- "@id": "urn:ex/vav-508-discharge-air-temp-sensor",
+ "@id": "urn:ex/room-118",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:ex/vav-508-air-out"
- }
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "urn:ex/vav-508-discharge-air-temp"
+ "@id": "urn:ex/room-118-hvac-domain"
}
]
},
{
- "@id": "urn:ex/vav-506-reheat-coil-valve-command",
+ "@id": "urn:ex/vav-509-damper-command",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -31047,61 +31286,67 @@
]
},
{
- "@id": "urn:ex/office-ahu-ra-fan-power",
+ "@id": "urn:ex/vav-526-duct-after-damper",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/W"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/room-208",
+ "@id": "urn:ex/vav-518-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-208-hvac-domain"
+ "@id": "urn:ex/vav-518-hot-water-out-connection"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/office-ahu-oa-flow-sensor",
+ "@id": "urn:ex/office-ahu-clg-coil-air-in",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-oa-damper-in"
+ "@id": "urn:ex/office-ahu-duct-after-htg-coil"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/office-ahu-oa-flow"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-532-more-heat-requests",
+ "@id": "urn:ex/zone-111-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/room-111-hvac-domain"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:ex/zone-111-temp"
}
]
},
{
- "@id": "urn:ex/vav-533-cooling-pid-output",
+ "@id": "urn:ex/vav-539-cooling-pid-output",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -31117,159 +31362,104 @@
]
},
{
- "@id": "urn:ex/vav-508-damper-command",
+ "@id": "urn:ex/vav-506-heating-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-510-air-out",
+ "@id": "urn:ex/vav-515-damper",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-111"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:ex/vav-515-damper-in"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-515-damper-out"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-510-discharge-air-flow"
- },
- {
- "@id": "urn:ex/vav-510-discharge-air-flow-setpoint"
- },
- {
- "@id": "urn:ex/vav-510-discharge-air-temp"
+ "@id": "urn:ex/vav-515-damper-command"
},
{
- "@id": "urn:ex/vav-510-discharge-air-temp-setpoint"
+ "@id": "urn:ex/vav-515-damper-position"
}
]
},
{
- "@id": "urn:ex/vav-510-reheat-coil-valve",
+ "@id": "urn:ex/room-108-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-510-reheat-coil-valve-in"
+ "@id": "urn:ex/room-108-in"
},
{
- "@id": "urn:ex/vav-510-reheat-coil-valve-out"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "urn:ex/room-108-out"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-510-reheat-coil-valve-command"
- },
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:ex/vav-510-reheat-coil-valve-position"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/zone-113-heating-setpoint",
+ "@id": "urn:ex/vav-510-damper-command",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-534-discharge-air-temp-sensor",
+ "@id": "urn:ex/vav-520-air-in",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:ex/vav-534-air-out"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-534-discharge-air-temp"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
- ]
- },
- {
- "@id": "urn:ex/zone-104-window-switch-on-off",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-520",
+ "@id": "urn:ex/room-302-out",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-520-air-in"
- },
- {
- "@id": "urn:ex/vav-520-air-out"
- },
- {
- "@id": "urn:ex/vav-520-hot-water-in"
- },
- {
- "@id": "urn:ex/vav-520-hot-water-out"
- }
- ],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/vav-520-damper"
- },
- {
- "@id": "urn:ex/vav-520-reheat-coil"
- },
- {
- "@id": "urn:ex/vav-520-reheat-coil-valve"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
- ]
- },
- {
- "@id": "urn:ex/vav-540-duct-after-damper",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -31278,162 +31468,158 @@
]
},
{
- "@id": "urn:ex/zone-313-occupancy-sensor",
+ "@id": "urn:ex/vav-519-reheat-coil-valve-command",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-313-hvac-domain"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/zone-313-occupancy"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-533-reheat-coil-valve",
+ "@id": "urn:ex/vav-516-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-533-reheat-coil-valve-in"
- },
- {
- "@id": "urn:ex/vav-533-reheat-coil-valve-out"
+ "@id": "urn:ex/vav-516-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-521-reheat-coil-valve-command",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-533-reheat-coil-valve-command"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-533-reheat-coil-valve-position"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-532-discharge-air-flow",
+ "@id": "urn:ex/vav-514-reheat-coil-air-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:ex/vav-514-duct-after-damper"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/zone-103-heating-setpoint",
+ "@id": "urn:ex/vav-526-discharge-air-flow-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/zone-312",
+ "@id": "urn:ex/vav-506-reheat-coil-air-out",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-312-hvac-domain"
+ "@id": "urn:ex/connection-to-room-106-107"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/zone-312-cooling-setpoint"
- },
- {
- "@id": "urn:ex/zone-312-heating-setpoint"
- },
- {
- "@id": "urn:ex/zone-312-occupancy"
- },
- {
- "@id": "urn:ex/zone-312-occupancy-override"
+ "@id": "urn:ex/vav-506-heating-pid-output"
},
{
- "@id": "urn:ex/zone-312-temp"
- },
+ "@id": "urn:ex/vav-506-more-heat-requests"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/zone-312-window-switch-on-off"
+ "@id": "urn:ex/vav-506-air-out"
}
]
},
{
- "@id": "urn:ex/vav-506-discharge-air-temp-setpoint",
+ "@id": "urn:ex/vav-530-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-530-pipe-hot-water-return-before-valve"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-505-reheat-coil-water-in",
+ "@id": "urn:ex/vav-502-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-505-hot-water-in-connection"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:ex/vav-502-reheat-coil-air-in"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-502-reheat-coil-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-502-reheat-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-502-reheat-coil-water-out"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "urn:ex/vav-505-hot-water-in"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/vav-527-hot-water-in-connection",
+ "@id": "urn:ex/vav-501-pipe-hot-water-return-before-valve",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Pipe"
@@ -31445,192 +31631,176 @@
]
},
{
- "@id": "urn:ex/vav-532-reheat-coil-valve-actuator",
+ "@id": "urn:ex/vav-522-reheat-coil-valve-actuator",
"@type": [
"http://data.ashrae.org/standard223#Actuator"
],
"http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/vav-532-reheat-coil-valve"
+ "@id": "urn:ex/vav-522-reheat-coil-valve"
}
],
"http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/vav-532-reheat-coil-valve-command"
+ "@id": "urn:ex/vav-522-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/connection-to-room-307-308",
+ "@id": "urn:ex/vav-506-hot-water-in-connection",
"@type": [
"http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-539-reheat-coil-valve-position",
+ "@id": "urn:ex/vav-519",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "urn:ex/vav-519-air-in"
+ },
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-526-damper-in",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
+ "@id": "urn:ex/vav-519-air-out"
+ },
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:ex/vav-519-hot-water-in"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-519-hot-water-out"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/vav-526-air-in"
- }
- ]
- },
- {
- "@id": "urn:ex/zone-102-cooling-setpoint",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "@id": "urn:ex/vav-519-damper"
+ },
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "urn:ex/vav-519-reheat-coil"
+ },
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-519-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/vav-509-air-in",
+ "@id": "urn:ex/vav-534-air-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/connection-to-room-314"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/office-ahu-oa-temp-sensor",
- "@type": [
- "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/office-ahu-oa-damper-in"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
+ "@id": "urn:ex/vav-534-discharge-air-flow"
+ },
{
- "@id": "urn:ex/office-ahu-oa-temp"
+ "@id": "urn:ex/vav-534-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-534-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-534-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/vav-502-discharge-air-flow-sensor",
+ "@id": "urn:ex/vav-530-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-502-air-in"
+ "@id": "urn:ex/vav-530-pipe-hot-water-return-before-valve"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-502-discharge-air-flow"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-503-reheat-coil-valve-in",
+ "@id": "urn:ex/room-104-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-503-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/room-104-in"
+ },
+ {
+ "@id": "urn:ex/room-104-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-529-reheat-coil-valve-command",
+ "@id": "urn:ex/zone-112-114-cooling-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-534-damper-in",
+ "@id": "urn:ex/vav-514-reheat-coil-valve-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-514-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-534-air-in"
+ "@id": "urn:ex/vav-514-hot-water-out"
}
]
},
{
- "@id": "urn:ex/vav-526-duct-after-damper",
+ "@id": "urn:ex/room-206-out",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -31639,25 +31809,25 @@
]
},
{
- "@id": "urn:ex/vav-518-hot-water-in-connection",
+ "@id": "urn:ex/connection-to-room-203",
"@type": [
"http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-520-damper-in",
+ "@id": "urn:ex/vav-508-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-508-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -31665,136 +31835,123 @@
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-520-air-in"
+ "@id": "urn:ex/vav-508-colder-supply-air-requests"
+ },
+ {
+ "@id": "urn:ex/vav-508-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/vav-511-discharge-air-flow-setpoint",
+ "@id": "urn:ex/vav-501-damper-command",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-540-reheat-coil-air-out",
+ "@id": "urn:ex/room-205-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-215"
+ "@id": "urn:ex/connection-to-room-204-205"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-540-heating-pid-output"
- },
- {
- "@id": "urn:ex/vav-540-more-heat-requests"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-540-air-out"
- }
]
},
{
- "@id": "urn:ex/office-ahu-sa-fan-speed-cmd",
+ "@id": "urn:ex/room-104-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/connection-to-room-104"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-540-heating-pid-output",
+ "@id": "urn:ex/vav-509-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/vav-509-pipe-hot-water-return-before-valve"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-501-reheat-coil-valve-out",
+ "@id": "urn:ex/vav-536-discharge-air-flow",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/vav-501-hot-water-out-connection"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-501-hot-water-out"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/office-ahu-ra-in",
+ "@id": "urn:ex/vav-540-discharge-air-temp",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/office-ahu-ra-flow"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/office-ahu-ra-temp"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/zone-309-310-occupancy",
+ "@id": "urn:ex/zone-307-308-occupancy",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
@@ -31805,93 +31962,85 @@
]
},
{
- "@id": "urn:ex/vav-506-more-heat-requests",
+ "@id": "urn:ex/vav-515-pipe-hot-water-return-before-valve",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-538-reheat-coil-valve-in",
+ "@id": "urn:ex/room-110-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-538-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/connection-to-room-110"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-522-hot-water-in",
+ "@id": "urn:ex/zone-203-window-switch-on-off",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-522-hot-water-in-connection"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/vav-532-cooling-pid-output",
+ "@id": "urn:ex/vav-516-reheat-coil-valve-command",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/office-ahu-oa-damper-out",
+ "@id": "urn:ex/vav-509-colder-supply-air-requests",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/office-ahu-duct-after-oa-ra-damper"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/room-304",
+ "@id": "urn:ex/vav-506-hot-water-out-connection",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/room-304-hvac-domain"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/zone-202-cooling-setpoint",
+ "@id": "urn:ex/zone-105-cooling-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -31907,34 +32056,24 @@
]
},
{
- "@id": "urn:ex/vav-526-reheat-coil-water-in",
+ "@id": "urn:ex/vav-501-more-heat-requests",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-526-hot-water-in-connection"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-526-hot-water-in"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-536-reheat-coil-air-in",
+ "@id": "urn:ex/room-211-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-536-duct-after-damper"
+ "@id": "urn:ex/connection-to-room-211"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -31944,161 +32083,90 @@
]
},
{
- "@id": "urn:ex/vav-503-discharge-air-temp-sensor",
- "@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:ex/vav-503-air-out"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
- {
- "@id": "urn:ex/vav-503-discharge-air-temp"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-533",
+ "@id": "urn:ex/room-102-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-533-air-in"
- },
- {
- "@id": "urn:ex/vav-533-air-out"
- },
- {
- "@id": "urn:ex/vav-533-hot-water-in"
- },
- {
- "@id": "urn:ex/vav-533-hot-water-out"
- }
- ],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/vav-533-damper"
- },
- {
- "@id": "urn:ex/vav-533-reheat-coil"
+ "@id": "urn:ex/room-102-in"
},
{
- "@id": "urn:ex/vav-533-reheat-coil-valve"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-527-colder-supply-air-requests",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-518-hot-water-out",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-518-hot-water-out-connection"
+ "@id": "urn:ex/room-102-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/zone-110-temp",
+ "@id": "urn:ex/vav-504-cooling-pid-output",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/zone-104",
+ "@id": "urn:ex/zone-118-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
- ],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/room-104-hvac-domain"
- }
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "urn:ex/room-118-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/zone-104-cooling-setpoint"
- },
- {
- "@id": "urn:ex/zone-104-heating-setpoint"
- },
- {
- "@id": "urn:ex/zone-104-occupancy"
- },
- {
- "@id": "urn:ex/zone-104-occupancy-override"
- },
- {
- "@id": "urn:ex/zone-104-temp"
- },
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/zone-104-window-switch-on-off"
+ "@id": "urn:ex/zone-118-temp"
}
]
},
{
- "@id": "urn:ex/vav-532-reheat-coil",
+ "@id": "urn:ex/vav-531",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-532-reheat-coil-air-in"
+ "@id": "urn:ex/vav-531-air-in"
},
{
- "@id": "urn:ex/vav-532-reheat-coil-air-out"
+ "@id": "urn:ex/vav-531-air-out"
},
{
- "@id": "urn:ex/vav-532-reheat-coil-water-in"
+ "@id": "urn:ex/vav-531-hot-water-in"
},
{
- "@id": "urn:ex/vav-532-reheat-coil-water-out"
+ "@id": "urn:ex/vav-531-hot-water-out"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "urn:ex/vav-531-damper"
+ },
+ {
+ "@id": "urn:ex/vav-531-reheat-coil"
+ },
+ {
+ "@id": "urn:ex/vav-531-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/zone-106-107-heating-setpoint",
+ "@id": "urn:ex/zone-215-cooling-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -32114,66 +32182,50 @@
]
},
{
- "@id": "urn:ex/vav-535-cooling-pid-output",
+ "@id": "urn:ex/zone-115-occupancy-override",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
]
},
{
- "@id": "urn:ex/vav-503-damper-out",
+ "@id": "urn:ex/room-201-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-503-duct-after-damper"
+ "@id": "urn:ex/connection-to-room-201"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-503-colder-supply-air-requests"
- },
- {
- "@id": "urn:ex/vav-503-cooling-pid-output"
- }
]
},
{
- "@id": "urn:ex/room-206-hvac-domain",
+ "@id": "urn:ex/vav-501-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-206-in"
- },
- {
- "@id": "urn:ex/room-206-out"
+ "@id": "urn:ex/vav-501-pipe-hot-water-return-before-valve"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-526-air-in",
+ "@id": "urn:ex/vav-519-damper-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -32186,175 +32238,103 @@
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/vav-521",
- "@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-521-air-in"
- },
- {
- "@id": "urn:ex/vav-521-air-out"
- },
- {
- "@id": "urn:ex/vav-521-hot-water-in"
- },
- {
- "@id": "urn:ex/vav-521-hot-water-out"
- }
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/vav-521-damper"
- },
- {
- "@id": "urn:ex/vav-521-reheat-coil"
- },
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-521-reheat-coil-valve"
+ "@id": "urn:ex/vav-519-air-in"
}
]
},
{
- "@id": "urn:ex/vav-522-air-out",
+ "@id": "urn:ex/room-304-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-208-209"
+ "@id": "urn:ex/connection-to-room-303-304-306"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-522-discharge-air-flow"
- },
- {
- "@id": "urn:ex/vav-522-discharge-air-flow-setpoint"
- },
- {
- "@id": "urn:ex/vav-522-discharge-air-temp"
- },
- {
- "@id": "urn:ex/vav-522-discharge-air-temp-setpoint"
- }
]
},
{
- "@id": "urn:ex/vav-507-hot-water-out",
+ "@id": "urn:ex/vav-505-reheat-coil-valve-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-507-hot-water-out-connection"
+ "@id": "urn:ex/vav-505-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-505-hot-water-out"
+ }
]
},
{
- "@id": "urn:ex/vav-524-reheat-coil",
+ "@id": "urn:ex/vav-508-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-524-reheat-coil-air-in"
- },
- {
- "@id": "urn:ex/vav-524-reheat-coil-air-out"
- },
- {
- "@id": "urn:ex/vav-524-reheat-coil-water-in"
- },
- {
- "@id": "urn:ex/vav-524-reheat-coil-water-out"
+ "@id": "urn:ex/vav-508-hot-water-in-connection"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
- ]
- },
- {
- "@id": "urn:ex/zone-303-304-306-occupancy-override",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "urn:ex/vav-508-hot-water-in"
}
]
},
{
- "@id": "urn:ex/vav-514-damper-command",
+ "@id": "urn:ex/zone-201-cooling-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-508-reheat-coil-valve-out",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-508-hot-water-out-connection"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-508-hot-water-out"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-531-more-heat-requests",
+ "@id": "urn:ex/connection-to-room-311",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-521-reheat-coil-valve-command",
+ "@id": "urn:ex/vav-502-reheat-coil-valve-position",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -32368,64 +32348,68 @@
]
},
{
- "@id": "urn:ex/vav-508-hot-water-in-connection",
+ "@id": "urn:ex/zone-105-occupancy-sensor",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/room-105-hvac-domain"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:ex/zone-105-occupancy"
}
]
},
{
- "@id": "urn:ex/vav-521-discharge-air-flow-setpoint",
+ "@id": "urn:ex/vav-508-damper",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:ex/vav-508-damper-in"
+ },
+ {
+ "@id": "urn:ex/vav-508-damper-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:ex/vav-508-damper-command"
+ },
+ {
+ "@id": "urn:ex/vav-508-damper-position"
}
]
},
{
- "@id": "urn:ex/vav-523-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/zone-307-308-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
- ]
- },
- {
- "@id": "urn:ex/zone-207-occupancy",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/room-111-in",
+ "@id": "urn:ex/vav-528-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-111"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -32435,109 +32419,115 @@
]
},
{
- "@id": "urn:ex/room-201-in",
+ "@id": "urn:ex/vav-533-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/connection-to-room-201"
+ "@id": "urn:ex/vav-533-air-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-533-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/vav-510-cooling-pid-output",
+ "@id": "urn:ex/zone-204-205-occupancy-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/room-204-hvac-domain"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "urn:ex/zone-204-205-occupancy"
}
]
},
{
- "@id": "urn:ex/vav-504-damper-position",
+ "@id": "urn:ex/zone-106-107-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/room-106-hvac-domain"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/zone-106-107-temp"
}
]
},
{
- "@id": "urn:ex/zone-108-temp-sensor",
+ "@id": "urn:ex/zone-206-occupancy-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/room-108-hvac-domain"
+ "@id": "urn:ex/room-206-hvac-domain"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/zone-108-temp"
+ "@id": "urn:ex/zone-206-occupancy"
}
]
},
{
- "@id": "urn:ex/vav-516-damper-actuator",
+ "@id": "urn:ex/vav-518-damper-actuator",
"@type": [
"http://data.ashrae.org/standard223#Actuator"
],
"http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/vav-516-damper"
+ "@id": "urn:ex/vav-518-damper"
}
],
"http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/vav-516-damper-command"
+ "@id": "urn:ex/vav-518-damper-command"
}
]
},
{
- "@id": "urn:ex/room-108-in",
+ "@id": "urn:ex/room-204",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "urn:ex/connection-to-room-108"
+ "@id": "urn:ex/room-204-hvac-domain"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/room-113",
+ "@type": [
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/room-113-hvac-domain"
}
]
},
{
- "@id": "urn:ex/vav-538-air-out",
+ "@id": "urn:ex/vav-507-reheat-coil-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-213"
+ "@id": "urn:ex/connection-to-room-110"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -32547,49 +32537,60 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-538-discharge-air-flow"
- },
- {
- "@id": "urn:ex/vav-538-discharge-air-flow-setpoint"
+ "@id": "urn:ex/vav-507-heating-pid-output"
},
{
- "@id": "urn:ex/vav-538-discharge-air-temp"
- },
+ "@id": "urn:ex/vav-507-more-heat-requests"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-538-discharge-air-temp-setpoint"
+ "@id": "urn:ex/vav-507-air-out"
}
]
},
{
- "@id": "urn:ex/vav-505-reheat-coil-valve",
+ "@id": "urn:ex/connection-to-room-101",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-505-reheat-coil-valve-in"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-505-reheat-coil-valve-out"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-519-duct-after-damper",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-526-reheat-coil-water-out",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-505-reheat-coil-valve-command"
- },
+ "@id": "urn:ex/vav-526-pipe-hot-water-return-before-valve"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-505-reheat-coil-valve-position"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/zone-215-occupancy",
+ "@id": "urn:ex/zone-206-occupancy",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
@@ -32600,192 +32601,270 @@
]
},
{
- "@id": "urn:ex/zone-311-occupancy",
+ "@id": "urn:ex/zone-211-window-switch-on-off",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/room-104",
+ "@id": "urn:ex/office-ahu-clg-coil-air-out",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-104-hvac-domain"
+ "@id": "urn:ex/office-ahu-duct-after-clg-coil"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/zone-214-occupancy-sensor",
+ "@id": "urn:ex/vav-522-damper-command",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-303-304-306-temp-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/room-214-hvac-domain"
+ "@id": "urn:ex/room-303-hvac-domain"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/zone-214-occupancy"
+ "@id": "urn:ex/zone-303-304-306-temp"
}
]
},
{
- "@id": "urn:ex/zone-311",
+ "@id": "urn:ex/room-311-out",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-311-hvac-domain"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-532-reheat-coil-valve-actuator",
+ "@type": [
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/zone-311-cooling-setpoint"
- },
+ "@id": "urn:ex/vav-532-reheat-coil-valve"
+ }
+ ],
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/zone-311-heating-setpoint"
- },
+ "@id": "urn:ex/vav-532-reheat-coil-valve-command"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-314-cooling-setpoint",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/zone-311-occupancy"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/zone-311-occupancy-override"
- },
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-525-damper-command",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/zone-311-temp"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/zone-311-window-switch-on-off"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-525-reheat-coil-valve",
+ "@id": "urn:ex/connection-to-room-202",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-525-reheat-coil-valve-in"
- },
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-517-reheat-coil-water-in",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-525-reheat-coil-valve-out"
+ "@id": "urn:ex/vav-517-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-525-reheat-coil-valve-command"
- },
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-525-reheat-coil-valve-position"
+ "@id": "urn:ex/vav-517-hot-water-in"
}
]
},
{
- "@id": "urn:ex/vav-539-cooling-pid-output",
+ "@id": "urn:ex/vav-533-damper-position",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-514-damper-position",
+ "@id": "urn:ex/vav-517-discharge-air-temp-sensor",
+ "@type": [
+ "http://data.ashrae.org/standard223#Sensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "urn:ex/vav-517-air-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:ex/vav-517-discharge-air-temp"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-505-heating-pid-output",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-534-reheat-coil-air-in",
+ "@id": "urn:ex/vav-531-reheat-coil-valve-position",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-534-duct-after-damper"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-513-damper-position",
+ "@id": "urn:ex/vav-512-discharge-air-flow",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
+ "http://data.ashrae.org/standard223#hasAspect": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
+ ],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-525-duct-after-damper",
+ "@id": "urn:ex/vav-502-cooling-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-516-air-out",
+ "@id": "urn:ex/vav-530-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-201"
+ "@id": "urn:ex/connection-to-room-303-304-306"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -32795,185 +32874,184 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-516-discharge-air-flow"
+ "@id": "urn:ex/vav-530-discharge-air-flow"
},
{
- "@id": "urn:ex/vav-516-discharge-air-flow-setpoint"
+ "@id": "urn:ex/vav-530-discharge-air-flow-setpoint"
},
{
- "@id": "urn:ex/vav-516-discharge-air-temp"
+ "@id": "urn:ex/vav-530-discharge-air-temp"
},
{
- "@id": "urn:ex/vav-516-discharge-air-temp-setpoint"
+ "@id": "urn:ex/vav-530-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/vav-535-reheat-coil-valve-actuator",
+ "@id": "urn:ex/vav-525-colder-supply-air-requests",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
- ],
- "http://data.ashrae.org/standard223#actuates": [
- {
- "@id": "urn:ex/vav-535-reheat-coil-valve"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-535-reheat-coil-valve-command"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-525-damper-position",
+ "@id": "urn:ex/vav-525-discharge-air-flow-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-514-hot-water-out-connection",
+ "@id": "urn:ex/vav-540-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-540-reheat-coil-valve"
}
- ]
- },
- {
- "@id": "urn:ex/zone-309-310-occupancy-override",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "urn:ex/vav-540-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/room-212-in",
+ "@id": "urn:ex/vav-516-reheat-coil-valve-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-212"
+ "@id": "urn:ex/vav-516-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/zone-104-cooling-setpoint",
+ "@id": "urn:ex/vav-527-air-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/connection-to-room-301"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-527-discharge-air-flow"
+ },
+ {
+ "@id": "urn:ex/vav-527-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-527-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-527-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/vav-532-discharge-air-temp-setpoint",
+ "@id": "urn:ex/vav-522-hot-water-in-connection",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/connection-to-room-206",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-509-reheat-coil",
+ "@id": "urn:ex/vav-522-reheat-coil-air-in",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-509-reheat-coil-air-in"
- },
- {
- "@id": "urn:ex/vav-509-reheat-coil-air-out"
- },
- {
- "@id": "urn:ex/vav-509-reheat-coil-water-in"
- },
- {
- "@id": "urn:ex/vav-509-reheat-coil-water-out"
+ "@id": "urn:ex/vav-522-duct-after-damper"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-513-discharge-air-flow-sensor",
+ "@id": "urn:ex/vav-539-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-513-air-in"
+ "@id": "urn:ex/vav-539-hot-water-out-connection"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-513-discharge-air-flow"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-515-discharge-air-flow-setpoint",
+ "@id": "urn:ex/vav-519-colder-supply-air-requests",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/office-ahu-duct-after-oa-ra-damper",
+ "@id": "urn:ex/vav-524-reheat-coil-air-in",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-524-duct-after-damper"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -32982,7 +33060,7 @@
]
},
{
- "@id": "urn:ex/connection-to-room-213",
+ "@id": "urn:ex/connection-to-room-305",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Duct"
@@ -32994,23 +33072,23 @@
]
},
{
- "@id": "urn:ex/vav-529-damper-actuator",
+ "@id": "urn:ex/office-ahu-ea-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-529-damper"
+ "@id": "urn:ex/office-ahu-duct-after-ra-fan"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-529-damper-command"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-538-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/vav-518-hot-water-out-connection",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Pipe"
@@ -33022,25 +33100,30 @@
]
},
{
- "@id": "urn:ex/vav-515-reheat-coil-water-out",
+ "@id": "urn:ex/vav-508-discharge-air-flow",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/vav-515-pipe-hot-water-return-before-valve"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-518-discharge-air-temp-setpoint",
+ "@id": "urn:ex/zone-313-temp",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -33054,46 +33137,42 @@
]
},
{
- "@id": "urn:ex/zone-103",
+ "@id": "urn:ex/vav-540-hot-water-in",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-103-hvac-domain"
+ "@id": "urn:ex/vav-540-hot-water-in-connection"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/connection-to-room-201",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/zone-103-cooling-setpoint"
- },
- {
- "@id": "urn:ex/zone-103-heating-setpoint"
- },
- {
- "@id": "urn:ex/zone-103-occupancy"
- },
- {
- "@id": "urn:ex/zone-103-occupancy-override"
- },
- {
- "@id": "urn:ex/zone-103-temp"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-103-window-switch-on-off"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/zone-112-114-heating-setpoint",
+ "@id": "urn:ex/vav-504-discharge-air-temp",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasAspect": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -33107,92 +33186,67 @@
]
},
{
- "@id": "urn:ex/vav-527",
+ "@id": "urn:ex/vav-503-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-527-air-in"
- },
- {
- "@id": "urn:ex/vav-527-air-out"
- },
- {
- "@id": "urn:ex/vav-527-hot-water-in"
- },
- {
- "@id": "urn:ex/vav-527-hot-water-out"
+ "@id": "urn:ex/vav-503-hot-water-in-connection"
}
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/vav-527-damper"
- },
- {
- "@id": "urn:ex/vav-527-reheat-coil"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-527-reheat-coil-valve"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
- ]
- },
- {
- "@id": "urn:ex/vav-512-hot-water-out-connection",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-503-hot-water-in"
}
]
},
{
- "@id": "urn:ex/zone-309-310-cooling-setpoint",
+ "@id": "urn:ex/vav-538-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/zone-214-window-switch-on-off",
+ "@id": "urn:ex/vav-529-reheat-coil-valve-command",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
- ]
- },
- {
- "@id": "urn:ex/zone-206-occupancy",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-520-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/vav-520-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-520-hot-water-out-connection"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -33201,77 +33255,66 @@
]
},
{
- "@id": "urn:ex/room-310-out",
+ "@id": "urn:ex/vav-525-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-525-air-in"
+ }
]
},
{
- "@id": "urn:ex/vav-510",
+ "@id": "urn:ex/room-112",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-510-air-in"
- },
- {
- "@id": "urn:ex/vav-510-air-out"
- },
- {
- "@id": "urn:ex/vav-510-hot-water-in"
- },
- {
- "@id": "urn:ex/vav-510-hot-water-out"
- }
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/vav-510-damper"
- },
- {
- "@id": "urn:ex/vav-510-reheat-coil"
- },
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "urn:ex/vav-510-reheat-coil-valve"
+ "@id": "urn:ex/room-112-hvac-domain"
}
]
},
{
- "@id": "urn:ex/vav-508-reheat-coil-valve-actuator",
+ "@id": "urn:ex/vav-530-discharge-air-temp",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/vav-508-reheat-coil-valve"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-508-reheat-coil-valve-command"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-529-damper-out",
+ "@id": "urn:ex/vav-531-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-529-duct-after-damper"
+ "@id": "urn:ex/connection-to-room-307-308"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -33281,209 +33324,164 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-529-colder-supply-air-requests"
+ "@id": "urn:ex/vav-531-discharge-air-flow"
},
{
- "@id": "urn:ex/vav-529-cooling-pid-output"
+ "@id": "urn:ex/vav-531-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-531-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-531-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/vav-506-reheat-coil-valve-position",
+ "@id": "urn:ex/vav-519-heating-pid-output",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-503-discharge-air-flow-setpoint",
+ "@id": "urn:ex/room-105-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:ex/room-105-in"
+ },
+ {
+ "@id": "urn:ex/room-105-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/zone-202-temp-sensor",
+ "@id": "urn:ex/vav-529-discharge-air-temp",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/room-202-hvac-domain"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/zone-202-temp"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
- ]
- },
- {
- "@id": "urn:ex/vav-507-hot-water-out-connection",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-515-damper",
+ "@id": "urn:ex/vav-530-damper",
"@type": [
"http://data.ashrae.org/standard223#Damper",
"http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-515-damper-in"
+ "@id": "urn:ex/vav-530-damper-in"
},
{
- "@id": "urn:ex/vav-515-damper-out"
+ "@id": "urn:ex/vav-530-damper-out"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-515-damper-command"
+ "@id": "urn:ex/vav-530-damper-command"
},
{
- "@id": "urn:ex/vav-515-damper-position"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-539-more-heat-requests",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/vav-530-damper-position"
}
]
},
{
- "@id": "urn:ex/vav-537-colder-supply-air-requests",
+ "@id": "urn:ex/vav-506-air-in",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
- ]
- },
- {
- "@id": "urn:ex/vav-512-more-heat-requests",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-509",
+ "@id": "urn:ex/vav-510-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-509-air-in"
- },
- {
- "@id": "urn:ex/vav-509-air-out"
- },
- {
- "@id": "urn:ex/vav-509-hot-water-in"
+ "@id": "urn:ex/vav-510-reheat-coil-air-in"
},
{
- "@id": "urn:ex/vav-509-hot-water-out"
- }
- ],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/vav-509-damper"
+ "@id": "urn:ex/vav-510-reheat-coil-air-out"
},
{
- "@id": "urn:ex/vav-509-reheat-coil"
+ "@id": "urn:ex/vav-510-reheat-coil-water-in"
},
{
- "@id": "urn:ex/vav-509-reheat-coil-valve"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-502-damper-out",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-502-duct-after-damper"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-510-reheat-coil-water-out"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-502-colder-supply-air-requests"
- },
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "urn:ex/vav-502-cooling-pid-output"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/vav-501-damper-position",
+ "@id": "urn:ex/zone-109-temp",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-501-reheat-coil-air-out",
+ "@id": "urn:ex/vav-537-reheat-coil-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-102"
+ "@id": "urn:ex/connection-to-room-312"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -33493,52 +33491,57 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-501-heating-pid-output"
+ "@id": "urn:ex/vav-537-heating-pid-output"
},
{
- "@id": "urn:ex/vav-501-more-heat-requests"
+ "@id": "urn:ex/vav-537-more-heat-requests"
}
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-501-air-out"
+ "@id": "urn:ex/vav-537-air-out"
}
]
},
{
- "@id": "urn:ex/zone-311-occupancy-sensor",
+ "@id": "urn:ex/vav-530-discharge-air-temp-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/room-311-hvac-domain"
+ "@id": "urn:ex/vav-530-air-out"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/zone-311-occupancy"
+ "@id": "urn:ex/vav-530-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/vav-537-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-533-discharge-air-temp",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/vav-537-pipe-hot-water-return-before-valve"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-502-duct-after-damper",
+ "@id": "urn:ex/connection-to-room-215",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Duct"
@@ -33550,74 +33553,103 @@
]
},
{
- "@id": "urn:ex/room-112",
+ "@id": "urn:ex/vav-520",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-112-hvac-domain"
+ "@id": "urn:ex/vav-520-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-520-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-520-hot-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-520-hot-water-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#contains": [
+ {
+ "@id": "urn:ex/vav-520-damper"
+ },
+ {
+ "@id": "urn:ex/vav-520-reheat-coil"
+ },
+ {
+ "@id": "urn:ex/vav-520-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/connection-to-room-312",
+ "@id": "urn:ex/vav-505-hot-water-in",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-505-hot-water-in-connection"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/zone-115-heating-setpoint",
+ "@id": "urn:ex/vav-522-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-522-air-in"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-522-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/vav-523-reheat-coil-valve",
+ "@id": "urn:ex/vav-503-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-523-reheat-coil-valve-in"
- },
- {
- "@id": "urn:ex/vav-523-reheat-coil-valve-out"
+ "@id": "urn:ex/vav-503-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-305-temp",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-523-reheat-coil-valve-command"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-523-reheat-coil-valve-position"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/zone-207-heating-setpoint",
+ "@id": "urn:ex/vav-519-discharge-air-temp-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -33633,98 +33665,117 @@
]
},
{
- "@id": "urn:ex/vav-537-discharge-air-flow",
+ "@id": "urn:ex/vav-519-damper",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "@id": "urn:ex/vav-519-damper-in"
+ },
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:ex/vav-519-damper-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:ex/vav-519-damper-command"
+ },
+ {
+ "@id": "urn:ex/vav-519-damper-position"
}
]
},
{
- "@id": "urn:ex/vav-511-reheat-coil-valve-out",
+ "@id": "urn:ex/vav-504-damper-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-511-hot-water-out-connection"
+ "@id": "urn:ex/vav-504-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-511-hot-water-out"
+ "@id": "urn:ex/vav-504-colder-supply-air-requests"
+ },
+ {
+ "@id": "urn:ex/vav-504-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/vav-531-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-520-damper-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-531-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/vav-524-more-heat-requests",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/vav-520-air-in"
}
]
},
{
- "@id": "urn:ex/office-ahu-sa-fan-start-status",
+ "@id": "urn:ex/vav-504-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "urn:ex/vav-504-reheat-coil-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-504-reheat-coil-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-504-reheat-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-504-reheat-coil-water-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasRole": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/vav-504-colder-supply-air-requests",
+ "@id": "urn:ex/zone-201-occupancy-sensor",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/room-201-hvac-domain"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:ex/zone-201-occupancy"
}
]
},
{
- "@id": "urn:ex/vav-515-reheat-coil-valve-position",
+ "@id": "urn:ex/vav-501-reheat-coil-valve-position",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -33740,45 +33791,69 @@
]
},
{
- "@id": "urn:ex/vav-538-hot-water-in",
+ "@id": "urn:ex/vav-520-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-538-hot-water-in-connection"
+ "@id": "urn:ex/vav-520-reheat-coil-valve-in"
+ },
+ {
+ "@id": "urn:ex/vav-520-reheat-coil-valve-out"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-520-reheat-coil-valve-command"
+ },
+ {
+ "@id": "urn:ex/vav-520-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-503-discharge-air-temp-setpoint",
+ "@id": "urn:ex/office-ahu-ea-out-connection",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-522-discharge-air-flow-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-503-air-out",
+ "@id": "urn:ex/vav-502-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-104"
+ "@id": "urn:ex/connection-to-room-101"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -33788,55 +33863,43 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-503-discharge-air-flow"
+ "@id": "urn:ex/vav-502-discharge-air-flow"
},
{
- "@id": "urn:ex/vav-503-discharge-air-flow-setpoint"
+ "@id": "urn:ex/vav-502-discharge-air-flow-setpoint"
},
{
- "@id": "urn:ex/vav-503-discharge-air-temp"
+ "@id": "urn:ex/vav-502-discharge-air-temp"
},
{
- "@id": "urn:ex/vav-503-discharge-air-temp-setpoint"
+ "@id": "urn:ex/vav-502-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/vav-526-reheat-coil-valve",
+ "@id": "urn:ex/vav-532-hot-water-in",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-526-reheat-coil-valve-in"
- },
- {
- "@id": "urn:ex/vav-526-reheat-coil-valve-out"
+ "@id": "urn:ex/vav-532-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-526-reheat-coil-valve-command"
- },
- {
- "@id": "urn:ex/vav-526-reheat-coil-valve-position"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-521-reheat-coil-water-out",
+ "@id": "urn:ex/vav-534-hot-water-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-521-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-534-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -33846,13 +33909,29 @@
]
},
{
- "@id": "urn:ex/vav-532-reheat-coil-air-out",
+ "@id": "urn:ex/zone-215-occupancy-sensor",
+ "@type": [
+ "http://data.ashrae.org/standard223#Sensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "urn:ex/room-215-hvac-domain"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:ex/zone-215-occupancy"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-512-damper-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-309-310"
+ "@id": "urn:ex/vav-512-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -33862,177 +33941,192 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-532-heating-pid-output"
+ "@id": "urn:ex/vav-512-colder-supply-air-requests"
},
{
- "@id": "urn:ex/vav-532-more-heat-requests"
+ "@id": "urn:ex/vav-512-cooling-pid-output"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-525",
+ "@type": [
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-532-air-out"
+ "@id": "urn:ex/vav-525-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-525-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-525-hot-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-525-hot-water-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#contains": [
+ {
+ "@id": "urn:ex/vav-525-damper"
+ },
+ {
+ "@id": "urn:ex/vav-525-reheat-coil"
+ },
+ {
+ "@id": "urn:ex/vav-525-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/vav-506-damper-actuator",
+ "@id": "urn:ex/vav-509-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-506-damper"
+ "@id": "urn:ex/vav-509-duct-after-damper"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-506-damper-command"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-509-colder-supply-air-requests"
+ },
+ {
+ "@id": "urn:ex/vav-509-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/vav-530-discharge-air-flow-setpoint",
+ "@id": "urn:ex/vav-521-colder-supply-air-requests",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-111-occupancy",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
]
},
{
- "@id": "urn:ex/room-209-out",
+ "@id": "urn:ex/vav-526-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/connection-to-room-212"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/vav-511-discharge-air-flow-sensor",
- "@type": [
- "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-511-air-in"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
+ "@id": "urn:ex/vav-526-discharge-air-flow"
+ },
{
- "@id": "urn:ex/vav-511-discharge-air-flow"
+ "@id": "urn:ex/vav-526-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-526-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-526-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/vav-540-hot-water-in",
+ "@id": "urn:ex/room-117-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-540-hot-water-in-connection"
+ "@id": "urn:ex/connection-to-room-116-117"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-505-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/vav-512-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-512-hot-water-in-connection"
}
- ]
- },
- {
- "@id": "urn:ex/vav-527-hot-water-out-connection",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-512-hot-water-in"
+ }
]
},
{
- "@id": "urn:ex/vav-509-heating-pid-output",
+ "@id": "urn:ex/zone-203-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/room-203-hvac-domain"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "urn:ex/zone-203-temp"
}
]
},
{
- "@id": "urn:ex/vav-515-reheat-coil-valve-out",
+ "@id": "urn:ex/vav-540-hot-water-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-515-hot-water-out-connection"
+ "@id": "urn:ex/vav-540-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-515-hot-water-out"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-528-damper-position",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
- {
- "@id": "http://qudt.org/vocab/unit/PERCENT"
- }
]
},
{
- "@id": "urn:ex/zone-309-310-temp",
+ "@id": "urn:ex/zone-307-308-temp",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -34048,7 +34142,7 @@
]
},
{
- "@id": "urn:ex/vav-502-discharge-air-temp",
+ "@id": "urn:ex/vav-526-discharge-air-flow",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -34059,54 +34153,49 @@
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-505-reheat-coil-valve-out",
+ "@id": "urn:ex/vav-507-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-505-hot-water-out-connection"
- }
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-507-damper"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/vav-505-hot-water-out"
+ "@id": "urn:ex/vav-507-damper-command"
}
]
},
{
- "@id": "urn:ex/zone-102-heating-setpoint",
+ "@id": "urn:ex/vav-506-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/connection-to-room-309-310",
+ "@id": "urn:ex/connection-to-room-110",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Duct"
@@ -34118,78 +34207,67 @@
]
},
{
- "@id": "urn:ex/zone-204-205-temp-sensor",
+ "@id": "urn:ex/vav-531-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-204-hvac-domain"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
+ "@id": "urn:ex/vav-531-reheat-coil-air-in"
+ },
{
- "@id": "urn:ex/zone-204-205-temp"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-536-reheat-coil-valve-in",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
+ "@id": "urn:ex/vav-531-reheat-coil-air-out"
+ },
{
- "@id": "urn:ex/vav-536-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-531-reheat-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-531-reheat-coil-water-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/vav-519-hot-water-in",
+ "@id": "urn:ex/vav-534",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-519-hot-water-in-connection"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:ex/vav-534-air-in"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-504-hot-water-out",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
+ "@id": "urn:ex/vav-534-air-out"
+ },
{
- "@id": "urn:ex/vav-504-hot-water-out-connection"
+ "@id": "urn:ex/vav-534-hot-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-534-hot-water-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-534-damper"
+ },
+ {
+ "@id": "urn:ex/vav-534-reheat-coil"
+ },
+ {
+ "@id": "urn:ex/vav-534-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/vav-513-discharge-air-temp",
+ "@id": "urn:ex/vav-533-discharge-air-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -34203,112 +34281,118 @@
]
},
{
- "@id": "urn:ex/vav-534-cooling-pid-output",
+ "@id": "urn:ex/vav-518-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/vav-518-air-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "urn:ex/vav-518-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/vav-529-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/room-114-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/room-114-in"
+ },
+ {
+ "@id": "urn:ex/room-114-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasDomain": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-539-reheat-coil-air-in",
+ "@id": "urn:ex/vav-539-discharge-air-flow-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-539-duct-after-damper"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/zone-111-occupancy",
+ "@id": "urn:ex/zone-311-window-switch-on-off",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/vav-530-hot-water-in-connection",
+ "@id": "urn:ex/vav-513-colder-supply-air-requests",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/zone-104-occupancy-sensor",
+ "@id": "urn:ex/zone-301-cooling-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-104-hvac-domain"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/zone-104-occupancy"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-509-damper-actuator",
+ "@id": "urn:ex/vav-529-discharge-air-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-509-damper"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-509-damper-command"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-525-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-512-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-525-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-512-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -34318,61 +34402,53 @@
]
},
{
- "@id": "urn:ex/vav-517-damper-actuator",
+ "@id": "urn:ex/vav-536-damper-actuator",
"@type": [
"http://data.ashrae.org/standard223#Actuator"
],
"http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/vav-517-damper"
+ "@id": "urn:ex/vav-536-damper"
}
],
"http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/vav-517-damper-command"
+ "@id": "urn:ex/vav-536-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-523-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-530-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-523-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-530-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/zone-113-temp",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "urn:ex/vav-530-colder-supply-air-requests"
+ },
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-530-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/vav-526-damper-out",
+ "@id": "urn:ex/vav-534-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-526-duct-after-damper"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -34380,67 +34456,84 @@
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-526-colder-supply-air-requests"
- },
+ "@id": "urn:ex/vav-534-air-in"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-520-discharge-air-flow-sensor",
+ "@type": [
+ "http://data.ashrae.org/standard223#Sensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-526-cooling-pid-output"
+ "@id": "urn:ex/vav-520-air-in"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:ex/vav-520-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/vav-504-more-heat-requests",
+ "@id": "urn:ex/vav-538-duct-after-damper",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/office-ahu-air-filter-in",
+ "@id": "urn:ex/room-105-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-duct-after-oa-ra-damper"
+ "@id": "urn:ex/connection-to-room-105"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/office-ahu-ma-temp"
- }
]
},
{
- "@id": "urn:ex/vav-518-discharge-air-flow-sensor",
+ "@id": "urn:ex/vav-537-duct-after-damper",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-518-air-in"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-519-pipe-hot-water-return-before-valve",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-518-discharge-air-flow"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/zone-311-temp",
+ "@id": "urn:ex/zone-106-107-cooling-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -34454,321 +34547,247 @@
]
},
{
- "@id": "urn:ex/room-206",
+ "@id": "urn:ex/vav-509-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-206-hvac-domain"
+ "@id": "urn:ex/vav-509-pipe-hot-water-return-before-valve"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-536",
+ "@id": "urn:ex/zone-309-310",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-536-air-in"
- },
- {
- "@id": "urn:ex/vav-536-air-out"
- },
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/vav-536-hot-water-in"
+ "@id": "urn:ex/room-309-hvac-domain"
},
{
- "@id": "urn:ex/vav-536-hot-water-out"
+ "@id": "urn:ex/room-310-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/vav-536-damper"
- },
- {
- "@id": "urn:ex/vav-536-reheat-coil"
- },
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:ex/vav-536-reheat-coil-valve"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
- ]
- },
- {
- "@id": "urn:ex/vav-531",
- "@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-531-air-in"
+ "@id": "urn:ex/zone-309-310-cooling-setpoint"
},
{
- "@id": "urn:ex/vav-531-air-out"
+ "@id": "urn:ex/zone-309-310-heating-setpoint"
},
{
- "@id": "urn:ex/vav-531-hot-water-in"
+ "@id": "urn:ex/zone-309-310-occupancy"
},
{
- "@id": "urn:ex/vav-531-hot-water-out"
- }
- ],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/vav-531-damper"
+ "@id": "urn:ex/zone-309-310-occupancy-override"
},
{
- "@id": "urn:ex/vav-531-reheat-coil"
+ "@id": "urn:ex/zone-309-310-temp"
},
{
- "@id": "urn:ex/vav-531-reheat-coil-valve"
+ "@id": "urn:ex/zone-309-310-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-507-discharge-air-flow",
+ "@id": "urn:ex/vav-520-duct-after-damper",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-516-cooling-pid-output",
+ "@id": "urn:ex/vav-535-reheat-coil-valve-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/vav-535-hot-water-out-connection"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-535-hot-water-out"
}
]
},
{
- "@id": "urn:ex/vav-505-hot-water-in",
+ "@id": "urn:ex/vav-536-reheat-coil-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-505-hot-water-in-connection"
+ "@id": "urn:ex/vav-536-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-508-reheat-coil-water-in",
+ "@id": "urn:ex/vav-523-hot-water-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-508-hot-water-in-connection"
+ "@id": "urn:ex/vav-523-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-508-hot-water-in"
- }
]
},
{
- "@id": "urn:ex/vav-517-more-heat-requests",
+ "@id": "urn:ex/vav-524-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
- }
- ]
- },
- {
- "@id": "urn:ex/connection-to-room-115",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:ex/vav-524-reheat-coil-air-in"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-524-reheat-coil-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-524-reheat-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-524-reheat-coil-water-out"
}
- ]
- },
- {
- "@id": "urn:ex/vav-510-hot-water-out-connection",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/vav-516-discharge-air-temp",
+ "@id": "urn:ex/vav-533-colder-supply-air-requests",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-534-hot-water-in-connection",
+ "@id": "urn:ex/zone-207-occupancy",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
]
},
{
- "@id": "urn:ex/zone-208-209-occupancy-sensor",
+ "@id": "urn:ex/zone-118-occupancy-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/room-208-hvac-domain"
+ "@id": "urn:ex/room-118-hvac-domain"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/zone-208-209-occupancy"
+ "@id": "urn:ex/zone-118-occupancy"
}
]
},
{
- "@id": "urn:ex/vav-508-duct-after-damper",
+ "@id": "urn:ex/vav-533-hot-water-out-connection",
"@type": [
"http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-506-damper-in",
+ "@id": "urn:ex/vav-533-discharge-air-flow",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/office-ahu-connection-to-vavs"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/vav-506-air-in"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
- ]
- },
- {
- "@id": "urn:ex/vav-536-discharge-air-flow-sensor",
- "@type": [
- "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-536-air-in"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-536-discharge-air-flow"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/zone-207-occupancy-sensor",
+ "@id": "urn:ex/room-105",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:ex/room-207-hvac-domain"
- }
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "urn:ex/zone-207-occupancy"
+ "@id": "urn:ex/room-105-hvac-domain"
}
]
},
{
- "@id": "urn:ex/vav-539-heating-pid-output",
+ "@id": "urn:ex/vav-514-more-heat-requests",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-517-damper-in",
+ "@id": "urn:ex/vav-501-damper-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -34784,79 +34803,60 @@
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-517-air-in"
+ "@id": "urn:ex/vav-501-air-in"
}
]
},
{
- "@id": "urn:ex/vav-514-discharge-air-flow-setpoint",
+ "@id": "urn:ex/vav-531-discharge-air-temp-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-513-reheat-coil-air-in",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-513-duct-after-damper"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-531-damper-command",
+ "@id": "urn:ex/zone-307-308-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/room-307-hvac-domain"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/zone-307-308-temp"
}
]
},
{
- "@id": "urn:ex/room-114-hvac-domain",
+ "@id": "urn:ex/vav-540-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-114-in"
- },
- {
- "@id": "urn:ex/room-114-out"
+ "@id": "urn:ex/vav-540-pipe-hot-water-return-before-valve"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-511-duct-after-damper",
+ "@id": "urn:ex/vav-510-duct-after-damper",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Duct"
@@ -34868,53 +34868,29 @@
]
},
{
- "@id": "urn:ex/room-118-hvac-domain",
- "@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/room-118-in"
- },
- {
- "@id": "urn:ex/room-118-out"
- }
- ],
- "http://data.ashrae.org/standard223#hasDomain": [
- {
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-517-reheat-coil-water-in",
+ "@id": "urn:ex/vav-514-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-517-hot-water-in-connection"
- }
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-514-reheat-coil-valve"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/vav-517-hot-water-in"
+ "@id": "urn:ex/vav-514-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/vav-533-damper-in",
+ "@id": "urn:ex/vav-529-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-529-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -34922,331 +34898,312 @@
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-533-air-in"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-518-cooling-pid-output",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "urn:ex/vav-529-colder-supply-air-requests"
+ },
+ {
+ "@id": "urn:ex/vav-529-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/office-ahu-hot-water-in",
+ "@id": "urn:ex/vav-516-reheat-coil-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-hot-water-in-connection"
+ "@id": "urn:ex/vav-516-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-534-heating-pid-output",
+ "@id": "urn:ex/vav-508-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/vav-508-damper"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "urn:ex/vav-508-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-536-damper-position",
+ "@id": "urn:ex/vav-520-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-520-pipe-hot-water-return-before-valve"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-505-hot-water-out",
+ "@id": "urn:ex/vav-539",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-505-hot-water-out-connection"
+ "@id": "urn:ex/vav-539-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-539-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-539-hot-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-539-hot-water-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-539-damper"
+ },
+ {
+ "@id": "urn:ex/vav-539-reheat-coil"
+ },
+ {
+ "@id": "urn:ex/vav-539-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/zone-215-occupancy-sensor",
+ "@id": "urn:ex/vav-527-discharge-air-temp-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/room-215-hvac-domain"
+ "@id": "urn:ex/vav-527-air-out"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/zone-215-occupancy"
+ "@id": "urn:ex/vav-527-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/zone-105-occupancy",
+ "@id": "urn:ex/connection-to-room-115",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-540-damper",
+ "@id": "urn:ex/room-310-out",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-540-damper-in"
- },
- {
- "@id": "urn:ex/vav-540-damper-out"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-540-damper-command"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-540-damper-position"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/room-102-hvac-domain",
+ "@id": "urn:ex/vav-530-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/room-102-in"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-102-out"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-503-reheat-coil",
+ "@id": "urn:ex/zone-215-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-503-reheat-coil-air-in"
- },
- {
- "@id": "urn:ex/vav-503-reheat-coil-air-out"
- },
- {
- "@id": "urn:ex/vav-503-reheat-coil-water-in"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-503-reheat-coil-water-out"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-540-reheat-coil-valve-out",
+ "@id": "urn:ex/zone-206-co2-concentration-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#ofSubstance": [
{
- "@id": "urn:ex/vav-540-hot-water-out-connection"
+ "@id": "http://data.ashrae.org/standard223#Substance-CO2"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/MoleFraction"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-540-hot-water-out"
+ "@id": "http://qudt.org/vocab/unit/PPM"
}
]
},
{
- "@id": "urn:ex/vav-539-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/vav-535-colder-supply-air-requests",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-513-reheat-coil",
+ "@id": "urn:ex/vav-519-cooling-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-513-reheat-coil-air-in"
- },
- {
- "@id": "urn:ex/vav-513-reheat-coil-air-out"
- },
- {
- "@id": "urn:ex/vav-513-reheat-coil-water-in"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-513-reheat-coil-water-out"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-506-reheat-coil-air-out",
+ "@id": "urn:ex/zone-108-window-switch-on-off",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/connection-to-room-106-107"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-515-discharge-air-flow-sensor",
+ "@type": [
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-506-heating-pid-output"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-506-more-heat-requests"
+ "@id": "urn:ex/vav-515-air-in"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-506-air-out"
+ "@id": "urn:ex/vav-515-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/zone-303-304-306",
+ "@id": "urn:ex/vav-538-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/room-303-hvac-domain"
- },
- {
- "@id": "urn:ex/room-304-hvac-domain"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/room-306-hvac-domain"
+ "@id": "urn:ex/vav-538-air-in"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "urn:ex/vav-538-discharge-air-flow"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-517",
+ "@type": [
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/zone-303-304-306-cooling-setpoint"
+ "@id": "urn:ex/vav-517-air-in"
},
{
- "@id": "urn:ex/zone-303-304-306-heating-setpoint"
+ "@id": "urn:ex/vav-517-air-out"
},
{
- "@id": "urn:ex/zone-303-304-306-occupancy"
+ "@id": "urn:ex/vav-517-hot-water-in"
},
{
- "@id": "urn:ex/zone-303-304-306-occupancy-override"
+ "@id": "urn:ex/vav-517-hot-water-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#contains": [
+ {
+ "@id": "urn:ex/vav-517-damper"
},
{
- "@id": "urn:ex/zone-303-304-306-temp"
+ "@id": "urn:ex/vav-517-reheat-coil"
},
{
- "@id": "urn:ex/zone-303-304-306-window-switch-on-off"
+ "@id": "urn:ex/vav-517-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/vav-511-colder-supply-air-requests",
+ "@id": "urn:ex/vav-530-reheat-coil-valve-command",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-533-reheat-coil-valve-command",
+ "@id": "urn:ex/vav-515-damper-command",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -35262,34 +35219,45 @@
]
},
{
- "@id": "urn:ex/vav-525-damper-in",
+ "@id": "urn:ex/zone-302-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-113-cooling-setpoint",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-525-air-in"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-523-reheat-coil-air-in",
+ "@id": "urn:ex/vav-519-reheat-coil-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-523-duct-after-damper"
+ "@id": "urn:ex/vav-519-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -35299,65 +35267,101 @@
]
},
{
- "@id": "urn:ex/zone-309-310-occupancy-sensor",
+ "@id": "urn:ex/vav-536-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-309-hvac-domain"
+ "@id": "urn:ex/vav-536-reheat-coil-valve-in"
+ },
+ {
+ "@id": "urn:ex/vav-536-reheat-coil-valve-out"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-309-310-occupancy"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-536-reheat-coil-valve-command"
+ },
+ {
+ "@id": "urn:ex/vav-536-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-529-hot-water-out-connection",
+ "@id": "urn:ex/zone-302-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/room-302-hvac-domain"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:ex/zone-302-temp"
}
]
},
{
- "@id": "urn:ex/room-213",
+ "@id": "urn:ex/office-ahu-oa-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/room-213-hvac-domain"
+ "@id": "urn:ex/office-ahu-oa-damper-in"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:ex/office-ahu-oa-temp"
}
]
},
{
- "@id": "urn:ex/vav-510-air-in",
+ "@id": "urn:ex/vav-520-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-520-air-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-520-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/vav-509-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/vav-528-colder-supply-air-requests",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ {
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-507-reheat-coil-valve-in",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-507-pipe-hot-water-return-before-valve"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -35366,89 +35370,95 @@
]
},
{
- "@id": "urn:ex/zone-109-temp-sensor",
+ "@id": "urn:ex/zone-302-co2-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/room-109-hvac-domain"
+ "@id": "urn:ex/room-302-hvac-domain"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/zone-109-temp"
+ "@id": "urn:ex/zone-302-co2-concentration"
}
]
},
{
- "@id": "urn:ex/room-309",
+ "@id": "urn:ex/vav-534-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/room-309-hvac-domain"
+ "@id": "urn:ex/vav-534-damper"
+ }
+ ],
+ "http://data.ashrae.org/standard223#commandedByProperty": [
+ {
+ "@id": "urn:ex/vav-534-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-517-discharge-air-flow-sensor",
+ "@id": "urn:ex/office-ahu-ra-temp-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-517-air-in"
+ "@id": "urn:ex/office-ahu-ra-in"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-517-discharge-air-flow"
+ "@id": "urn:ex/office-ahu-ra-temp"
}
]
},
{
- "@id": "urn:ex/room-109-hvac-domain",
+ "@id": "urn:ex/zone-202",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/room-109-in"
- },
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/room-109-out"
+ "@id": "urn:ex/room-202-hvac-domain"
}
],
"http://data.ashrae.org/standard223#hasDomain": [
{
"@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
- ]
- },
- {
- "@id": "urn:ex/vav-504-pipe-hot-water-return-before-valve",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/zone-202-cooling-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-202-heating-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-202-occupancy"
+ },
+ {
+ "@id": "urn:ex/zone-202-occupancy-override"
+ },
+ {
+ "@id": "urn:ex/zone-202-temp"
+ },
+ {
+ "@id": "urn:ex/zone-202-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-523-discharge-air-temp",
+ "@id": "urn:ex/zone-311-temp",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
- ],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
"@id": "http://qudt.org/vocab/quantitykind/Temperature"
@@ -35461,140 +35471,116 @@
]
},
{
- "@id": "urn:ex/room-215",
+ "@id": "urn:ex/zone-103",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/room-215-hvac-domain"
+ "@id": "urn:ex/room-103-hvac-domain"
}
- ]
- },
- {
- "@id": "urn:ex/vav-520-reheat-coil-water-in",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:ex/vav-520-hot-water-in-connection"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "@id": "urn:ex/zone-103-cooling-setpoint"
+ },
{
- "@id": "urn:ex/vav-520-hot-water-in"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-533-reheat-coil-valve-in",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
+ "@id": "urn:ex/zone-103-heating-setpoint"
+ },
{
- "@id": "urn:ex/vav-533-pipe-hot-water-return-before-valve"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:ex/zone-103-occupancy"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ]
- },
- {
- "@id": "urn:ex/room-105-hvac-domain",
- "@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
- ],
- "http://data.ashrae.org/standard223#cnx": [
+ "@id": "urn:ex/zone-103-occupancy-override"
+ },
{
- "@id": "urn:ex/room-105-in"
+ "@id": "urn:ex/zone-103-temp"
},
{
- "@id": "urn:ex/room-105-out"
+ "@id": "urn:ex/zone-103-window-switch-on-off"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-531-hot-water-in-connection",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-521-damper-out",
+ "@id": "urn:ex/vav-519-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-521-duct-after-damper"
+ "@id": "urn:ex/vav-519-reheat-coil-valve-in"
+ },
+ {
+ "@id": "urn:ex/vav-519-reheat-coil-valve-out"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-521-colder-supply-air-requests"
+ "@id": "urn:ex/vav-519-reheat-coil-valve-command"
},
{
- "@id": "urn:ex/vav-521-cooling-pid-output"
+ "@id": "urn:ex/vav-519-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-524-reheat-coil-water-in",
+ "@id": "urn:ex/vav-507-discharge-air-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-524-hot-water-in-connection"
- }
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-524-hot-water-in"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-504-discharge-air-flow",
+ "@id": "urn:ex/vav-515-discharge-air-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-540-colder-supply-air-requests",
+ "@id": "urn:ex/office-ahu-colder-chilled-water-requests",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
@@ -35605,35 +35591,42 @@
]
},
{
- "@id": "urn:ex/office-ahu-hot-water-out-connection",
+ "@id": "urn:ex/room-206-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/room-206-in"
+ },
+ {
+ "@id": "urn:ex/room-206-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasDomain": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/office-ahu-htg-coil-valve-in",
+ "@id": "urn:ex/vav-507-heating-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/office-ahu-pipe-hot-water-return-before-valve"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-524-hot-water-in-connection",
+ "@id": "urn:ex/vav-523-pipe-hot-water-return-before-valve",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Pipe"
@@ -35645,107 +35638,96 @@
]
},
{
- "@id": "urn:ex/vav-510-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/vav-512-reheat-coil-valve-out",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-512-hot-water-out-connection"
}
- ]
- },
- {
- "@id": "urn:ex/vav-510-heating-pid-output",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "urn:ex/vav-512-hot-water-out"
}
]
},
{
- "@id": "urn:ex/vav-532-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/zone-103-occupancy",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
]
},
{
- "@id": "urn:ex/zone-106-107-cooling-setpoint",
+ "@id": "urn:ex/room-205-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/room-205-in"
+ },
+ {
+ "@id": "urn:ex/room-205-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-505-reheat-coil",
+ "@id": "urn:ex/vav-514-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-505-reheat-coil-air-in"
- },
- {
- "@id": "urn:ex/vav-505-reheat-coil-air-out"
- },
- {
- "@id": "urn:ex/vav-505-reheat-coil-water-in"
- },
+ "@id": "urn:ex/vav-514-duct-after-damper"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-505-reheat-coil-water-out"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "urn:ex/vav-514-colder-supply-air-requests"
+ },
+ {
+ "@id": "urn:ex/vav-514-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/vav-521-reheat-coil-air-in",
+ "@id": "urn:ex/vav-503-pipe-hot-water-return-before-valve",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-521-duct-after-damper"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-525-reheat-coil-valve-command",
+ "@id": "urn:ex/vav-520-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -35759,65 +35741,57 @@
]
},
{
- "@id": "urn:ex/vav-535-damper-out",
+ "@id": "urn:ex/vav-516-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-535-duct-after-damper"
- }
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-516-damper"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-535-colder-supply-air-requests"
- },
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/vav-535-cooling-pid-output"
+ "@id": "urn:ex/vav-516-damper-command"
}
]
},
{
- "@id": "urn:ex/room-112-out",
+ "@id": "urn:ex/vav-538-cooling-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-525-hot-water-in",
+ "@id": "urn:ex/vav-513-more-heat-requests",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-525-hot-water-in-connection"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-511-discharge-air-temp-setpoint",
+ "@id": "urn:ex/vav-516-discharge-air-temp",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasAspect": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -35831,56 +35805,45 @@
]
},
{
- "@id": "urn:ex/room-201",
- "@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
- ],
- "http://data.ashrae.org/standard223#encloses": [
- {
- "@id": "urn:ex/room-201-hvac-domain"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-513-discharge-air-temp-sensor",
+ "@id": "urn:ex/vav-508-reheat-coil-air-in",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-513-air-out"
+ "@id": "urn:ex/vav-508-duct-after-damper"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-513-discharge-air-temp"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/office-ahu-hot-water-out",
+ "@id": "urn:ex/vav-520-heating-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/office-ahu-hot-water-out-connection"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-513-air-out",
+ "@id": "urn:ex/vav-530-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-103"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -35888,78 +35851,96 @@
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-513-discharge-air-flow"
- },
- {
- "@id": "urn:ex/vav-513-discharge-air-flow-setpoint"
- },
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-513-discharge-air-temp"
- },
+ "@id": "urn:ex/vav-530-air-in"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/room-307",
+ "@type": [
+ "http://data.ashrae.org/standard223#PhysicalSpace"
+ ],
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "urn:ex/vav-513-discharge-air-temp-setpoint"
+ "@id": "urn:ex/room-307-hvac-domain"
}
]
},
{
- "@id": "urn:ex/vav-511-reheat-coil-air-in",
+ "@id": "urn:ex/office-ahu-moisture-eliminator-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-511-duct-after-damper"
+ "@id": "urn:ex/office-ahu-oa-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/office-ahu-oa-in"
+ }
]
},
{
- "@id": "urn:ex/zone-208-209-cooling-setpoint",
+ "@id": "urn:ex/zone-110-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/room-110-hvac-domain"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/zone-110-temp"
}
]
},
{
- "@id": "urn:ex/vav-539-discharge-air-flow",
+ "@id": "urn:ex/office-ahu-sa-fan-start-cmd",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-531-damper-command",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/zone-118-heating-setpoint",
+ "@id": "urn:ex/vav-524-discharge-air-temp",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasAspect": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -35973,116 +35954,106 @@
]
},
{
- "@id": "urn:ex/vav-502-reheat-coil-air-in",
+ "@id": "urn:ex/vav-502-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-502-duct-after-damper"
+ "@id": "urn:ex/vav-502-air-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-502-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/vav-512-reheat-coil-water-in",
+ "@id": "urn:ex/vav-517-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-512-hot-water-in-connection"
+ "@id": "urn:ex/vav-517-reheat-coil-valve-in"
+ },
+ {
+ "@id": "urn:ex/vav-517-reheat-coil-valve-out"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-512-hot-water-in"
+ "@id": "urn:ex/vav-517-reheat-coil-valve-command"
+ },
+ {
+ "@id": "urn:ex/vav-517-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-508-hot-water-in",
+ "@id": "urn:ex/vav-531-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-508-hot-water-in-connection"
+ "@id": "urn:ex/vav-531-air-in"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-531-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/vav-525-discharge-air-flow",
+ "@id": "urn:ex/zone-211-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-521-duct-after-damper",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-509-hot-water-in",
+ "@id": "urn:ex/vav-528-damper-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-509-hot-water-in-connection"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-528-air-in"
}
]
},
{
- "@id": "urn:ex/vav-526-discharge-air-flow",
+ "@id": "urn:ex/vav-506-discharge-air-flow-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -36096,125 +36067,106 @@
]
},
{
- "@id": "urn:ex/vav-511-damper-actuator",
+ "@id": "urn:ex/room-313-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-511-damper"
+ "@id": "urn:ex/room-313-in"
+ },
+ {
+ "@id": "urn:ex/room-313-out"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:ex/vav-511-damper-command"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-524-reheat-coil-valve-out",
+ "@id": "urn:ex/zone-302-co2-concentration-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#ofSubstance": [
{
- "@id": "urn:ex/vav-524-hot-water-out-connection"
+ "@id": "http://data.ashrae.org/standard223#Substance-CO2"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/MoleFraction"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-524-hot-water-out"
+ "@id": "http://qudt.org/vocab/unit/PPM"
}
]
},
{
- "@id": "urn:ex/vav-539-damper-command",
+ "@id": "urn:ex/vav-504-discharge-air-temp-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-503-discharge-air-flow",
+ "@id": "urn:ex/connection-to-room-111",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-505-damper-position",
+ "@id": "urn:ex/vav-504-duct-after-damper",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-513-damper-in",
+ "@id": "urn:ex/vav-507-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/office-ahu-connection-to-vavs"
- }
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-507-air-in"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-513-air-in"
+ "@id": "urn:ex/vav-507-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/room-107-in",
+ "@id": "urn:ex/connection-to-room-204-205",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/connection-to-room-106-107"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -36223,184 +36175,175 @@
]
},
{
- "@id": "urn:ex/vav-504-discharge-air-flow-setpoint",
+ "@id": "urn:ex/vav-538-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:ex/vav-538-hot-water-out-connection"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/office-ahu-htg-coil-valve",
+ "@id": "urn:ex/vav-536-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-htg-coil-valve-in"
- },
- {
- "@id": "urn:ex/office-ahu-htg-coil-valve-out"
+ "@id": "urn:ex/vav-536-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/office-ahu-htg-coil-valve-command"
+ "@id": "urn:ex/vav-536-colder-supply-air-requests"
},
{
- "@id": "urn:ex/office-ahu-htg-coil-valve-position"
+ "@id": "urn:ex/vav-536-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/vav-518-reheat-coil-water-out",
+ "@id": "urn:ex/room-210-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-518-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/zone-105-temp-sensor",
+ "@id": "urn:ex/vav-504-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-105-hvac-domain"
+ "@id": "urn:ex/vav-504-pipe-hot-water-return-before-valve"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-105-temp"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/connection-to-room-204-205",
+ "@id": "urn:ex/room-102",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/room-102-hvac-domain"
}
]
},
{
- "@id": "urn:ex/zone-301",
+ "@id": "urn:ex/vav-522-reheat-coil-valve-position",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
- ],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/room-301-hvac-domain"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/zone-301-cooling-setpoint"
- },
- {
- "@id": "urn:ex/zone-301-heating-setpoint"
- },
- {
- "@id": "urn:ex/zone-301-occupancy"
- },
- {
- "@id": "urn:ex/zone-301-occupancy-override"
- },
- {
- "@id": "urn:ex/zone-301-temp"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/zone-301-window-switch-on-off"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-537-damper-position",
+ "@id": "urn:ex/vav-522-cooling-pid-output",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-505-more-heat-requests",
+ "@id": "urn:ex/zone-104-occupancy",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
]
},
{
- "@id": "urn:ex/vav-522-damper",
+ "@id": "urn:ex/zone-204-205",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/vav-522-damper-in"
+ "@id": "urn:ex/room-204-hvac-domain"
},
{
- "@id": "urn:ex/vav-522-damper-out"
+ "@id": "urn:ex/room-205-hvac-domain"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasDomain": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-522-damper-command"
+ "@id": "urn:ex/zone-204-205-cooling-setpoint"
},
{
- "@id": "urn:ex/vav-522-damper-position"
+ "@id": "urn:ex/zone-204-205-heating-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-204-205-occupancy"
+ },
+ {
+ "@id": "urn:ex/zone-204-205-occupancy-override"
+ },
+ {
+ "@id": "urn:ex/zone-204-205-temp"
+ },
+ {
+ "@id": "urn:ex/zone-204-205-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/zone-203-heating-setpoint",
+ "@id": "urn:ex/zone-211-temp",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -36414,24 +36357,25 @@
]
},
{
- "@id": "urn:ex/vav-540-more-heat-requests",
+ "@id": "urn:ex/vav-507-hot-water-in-connection",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-518-reheat-coil-air-in",
+ "@id": "urn:ex/room-101-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-518-duct-after-damper"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -36441,71 +36385,83 @@
]
},
{
- "@id": "urn:ex/room-201-out",
+ "@id": "urn:ex/vav-535-reheat-coil-water-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/vav-535-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-526-reheat-coil-air-out",
+ "@id": "urn:ex/vav-537",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-212"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:ex/vav-537-air-in"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "@id": "urn:ex/vav-537-air-out"
+ },
{
- "@id": "urn:ex/vav-526-heating-pid-output"
+ "@id": "urn:ex/vav-537-hot-water-in"
},
{
- "@id": "urn:ex/vav-526-more-heat-requests"
+ "@id": "urn:ex/vav-537-hot-water-out"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/vav-526-air-out"
+ "@id": "urn:ex/vav-537-damper"
+ },
+ {
+ "@id": "urn:ex/vav-537-reheat-coil"
+ },
+ {
+ "@id": "urn:ex/vav-537-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/vav-540-hot-water-out",
+ "@id": "urn:ex/zone-206-co2-concentration",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#ofSubstance": [
{
- "@id": "urn:ex/vav-540-hot-water-out-connection"
+ "@id": "http://data.ashrae.org/standard223#Substance-CO2"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/MoleFraction"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PPM"
}
]
},
{
- "@id": "urn:ex/vav-522-duct-after-damper",
+ "@id": "urn:ex/vav-521-air-in",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -36514,109 +36470,95 @@
]
},
{
- "@id": "urn:ex/vav-517",
+ "@id": "urn:ex/vav-519-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-517-air-in"
+ "@id": "urn:ex/vav-519-reheat-coil-air-in"
},
{
- "@id": "urn:ex/vav-517-air-out"
+ "@id": "urn:ex/vav-519-reheat-coil-air-out"
},
{
- "@id": "urn:ex/vav-517-hot-water-in"
+ "@id": "urn:ex/vav-519-reheat-coil-water-in"
},
{
- "@id": "urn:ex/vav-517-hot-water-out"
+ "@id": "urn:ex/vav-519-reheat-coil-water-out"
}
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/vav-517-damper"
- },
- {
- "@id": "urn:ex/vav-517-reheat-coil"
- },
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "urn:ex/vav-517-reheat-coil-valve"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/vav-536-hot-water-in",
+ "@id": "urn:ex/vav-525-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-536-hot-water-in-connection"
+ "@id": "urn:ex/vav-525-reheat-coil-valve-in"
+ },
+ {
+ "@id": "urn:ex/vav-525-reheat-coil-valve-out"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
}
- ]
- },
- {
- "@id": "urn:ex/vav-506-reheat-coil-valve-actuator",
- "@type": [
- "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-506-reheat-coil-valve"
- }
- ],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "@id": "urn:ex/vav-525-reheat-coil-valve-command"
+ },
{
- "@id": "urn:ex/vav-506-reheat-coil-valve-command"
+ "@id": "urn:ex/vav-525-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-527-discharge-air-temp-sensor",
+ "@id": "urn:ex/vav-524-reheat-coil-valve-command",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-527-air-out"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-527-discharge-air-temp"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-531-reheat-coil-valve-position",
+ "@id": "urn:ex/vav-530-hot-water-out-connection",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-539-damper-out",
+ "@id": "urn:ex/vav-539-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-539-duct-after-damper"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -36624,167 +36566,211 @@
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-539-colder-supply-air-requests"
- },
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-539-cooling-pid-output"
+ "@id": "urn:ex/vav-539-air-in"
}
]
},
{
- "@id": "urn:ex/vav-521-damper-actuator",
+ "@id": "urn:ex/vav-529-damper",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-521-damper"
+ "@id": "urn:ex/vav-529-damper-in"
+ },
+ {
+ "@id": "urn:ex/vav-529-damper-out"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-521-damper-command"
+ "@id": "urn:ex/vav-529-damper-command"
+ },
+ {
+ "@id": "urn:ex/vav-529-damper-position"
}
]
},
{
- "@id": "urn:ex/vav-518",
+ "@id": "urn:ex/vav-502",
"@type": [
"http://data.ashrae.org/standard223#SingleDuctTerminal",
"http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-518-air-in"
+ "@id": "urn:ex/vav-502-air-in"
},
{
- "@id": "urn:ex/vav-518-air-out"
+ "@id": "urn:ex/vav-502-air-out"
},
{
- "@id": "urn:ex/vav-518-hot-water-in"
+ "@id": "urn:ex/vav-502-hot-water-in"
},
{
- "@id": "urn:ex/vav-518-hot-water-out"
+ "@id": "urn:ex/vav-502-hot-water-out"
}
],
"http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/vav-518-damper"
+ "@id": "urn:ex/vav-502-damper"
},
{
- "@id": "urn:ex/vav-518-reheat-coil"
+ "@id": "urn:ex/vav-502-reheat-coil"
},
{
- "@id": "urn:ex/vav-518-reheat-coil-valve"
+ "@id": "urn:ex/vav-502-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/vav-517-colder-supply-air-requests",
+ "@id": "urn:ex/connection-to-room-303-304-306",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-519-colder-supply-air-requests",
+ "@id": "urn:ex/vav-540-reheat-coil",
+ "@type": [
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-540-reheat-coil-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-540-reheat-coil-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-540-reheat-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-540-reheat-coil-water-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasRole": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-214-window-switch-on-off",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/vav-515-hot-water-out-connection",
+ "@id": "urn:ex/vav-536-duct-after-damper",
"@type": [
"http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-525-damper-out",
+ "@id": "urn:ex/vav-529-hot-water-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-525-duct-after-damper"
+ "@id": "urn:ex/vav-529-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-525-colder-supply-air-requests"
- },
- {
- "@id": "urn:ex/vav-525-cooling-pid-output"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-516-hot-water-out-connection",
+ "@id": "urn:ex/vav-523-reheat-coil-valve-command",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-511-hot-water-in",
+ "@id": "urn:ex/vav-514-damper-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-511-hot-water-in-connection"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-514-air-in"
}
]
},
{
- "@id": "urn:ex/vav-522-reheat-coil-water-out",
+ "@id": "urn:ex/vav-511-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-522-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-511-reheat-coil-valve-in"
+ },
+ {
+ "@id": "urn:ex/vav-511-reheat-coil-valve-out"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-511-reheat-coil-valve-command"
+ },
+ {
+ "@id": "urn:ex/vav-511-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/connection-to-room-116-117",
+ "@id": "urn:ex/vav-502-duct-after-damper",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Duct"
@@ -36796,66 +36782,78 @@
]
},
{
- "@id": "urn:ex/vav-540-discharge-air-flow-setpoint",
+ "@id": "urn:ex/zone-116-117-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:ex/room-116-hvac-domain"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:ex/zone-116-117-temp"
}
]
},
{
- "@id": "urn:ex/vav-527-discharge-air-temp-setpoint",
+ "@id": "urn:ex/vav-515-reheat-coil-air-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-515-duct-after-damper"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/zone-116-117-heating-setpoint",
+ "@id": "urn:ex/vav-521-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-521-reheat-coil-valve-in"
+ },
+ {
+ "@id": "urn:ex/vav-521-reheat-coil-valve-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-521-reheat-coil-valve-command"
+ },
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-521-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/zone-103-occupancy-override",
+ "@id": "urn:ex/zone-211-occupancy",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
]
},
{
- "@id": "urn:ex/connection-to-room-214",
+ "@id": "urn:ex/connection-to-room-113",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Duct"
@@ -36867,181 +36865,179 @@
]
},
{
- "@id": "urn:ex/vav-534-damper-out",
+ "@id": "urn:ex/vav-527-reheat-coil-valve-position",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-534-duct-after-damper"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-534-colder-supply-air-requests"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-534-cooling-pid-output"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/office-ahu-clg-coil-valve-actuator",
+ "@id": "urn:ex/room-209-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-clg-coil-valve"
+ "@id": "urn:ex/room-209-in"
+ },
+ {
+ "@id": "urn:ex/room-209-out"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:ex/office-ahu-clg-coil-valve-command"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/connection-to-room-311",
+ "@id": "urn:ex/vav-513-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-513-hot-water-in-connection"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-513-hot-water-in"
}
]
},
{
- "@id": "urn:ex/vav-523-reheat-coil-air-out",
+ "@id": "urn:ex/vav-536-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-206"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:ex/vav-536-reheat-coil-air-in"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "@id": "urn:ex/vav-536-reheat-coil-air-out"
+ },
{
- "@id": "urn:ex/vav-523-heating-pid-output"
+ "@id": "urn:ex/vav-536-reheat-coil-water-in"
},
{
- "@id": "urn:ex/vav-523-more-heat-requests"
+ "@id": "urn:ex/vav-536-reheat-coil-water-out"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "urn:ex/vav-523-air-out"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/vav-536-duct-after-damper",
+ "@id": "urn:ex/vav-504-colder-supply-air-requests",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/room-108-out",
+ "@id": "urn:ex/vav-510-discharge-air-temp",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/room-113-out",
+ "@id": "urn:ex/vav-522-hot-water-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/vav-522-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-524-reheat-coil-valve",
+ "@id": "urn:ex/vav-513-heating-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-524-reheat-coil-valve-in"
- },
- {
- "@id": "urn:ex/vav-524-reheat-coil-valve-out"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-524-reheat-coil-valve-command"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-524-reheat-coil-valve-position"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-505-discharge-air-temp",
+ "@id": "urn:ex/vav-532-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "@id": "urn:ex/vav-532-reheat-coil-air-in"
+ },
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-532-reheat-coil-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-532-reheat-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-532-reheat-coil-water-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/vav-536-reheat-coil-valve-position",
+ "@id": "urn:ex/vav-509-reheat-coil-valve-position",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -37057,44 +37053,68 @@
]
},
{
- "@id": "urn:ex/vav-525-reheat-coil-valve-out",
+ "@id": "urn:ex/vav-522-reheat-coil-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-525-hot-water-out-connection"
+ "@id": "urn:ex/connection-to-room-208-209"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-522-heating-pid-output"
+ },
+ {
+ "@id": "urn:ex/vav-522-more-heat-requests"
}
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-525-hot-water-out"
+ "@id": "urn:ex/vav-522-air-out"
}
]
},
{
- "@id": "urn:ex/office-ahu-ra-damper-position",
+ "@id": "urn:ex/vav-531-air-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-507-heating-pid-output",
+ "@id": "urn:ex/vav-511-reheat-coil-air-in",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-511-duct-after-damper"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-527-heating-pid-output",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -37110,262 +37130,259 @@
]
},
{
- "@id": "urn:ex/office-ahu-clg-coil-water-out",
+ "@id": "urn:ex/vav-522-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/office-ahu-pipe-chilled-water-return-before-valve"
+ "@id": "urn:ex/vav-522-air-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-522-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/vav-513-reheat-coil-valve-position",
+ "@id": "urn:ex/vav-502-pipe-hot-water-return-before-valve",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/zone-207-window-switch-on-off",
+ "@id": "urn:ex/zone-208-209-occupancy",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
]
},
{
- "@id": "urn:ex/zone-101-co2-concentration",
+ "@id": "urn:ex/vav-513-air-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#ofSubstance": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Substance-CO2"
+ "@id": "urn:ex/connection-to-room-103"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-513-discharge-air-flow"
+ },
+ {
+ "@id": "urn:ex/vav-513-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-513-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-513-discharge-air-temp-setpoint"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-111-cooling-setpoint",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/MoleFraction"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PPM"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-527-reheat-coil-water-in",
+ "@id": "urn:ex/office-ahu-ra-fan-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-527-hot-water-in-connection"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-527-hot-water-in"
+ "@id": "urn:ex/office-ahu-ra-in"
}
]
},
{
- "@id": "urn:ex/zone-213-occupancy-override",
+ "@id": "urn:ex/room-312",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "urn:ex/room-312-hvac-domain"
}
]
},
{
- "@id": "urn:ex/vav-533-discharge-air-flow-sensor",
+ "@id": "urn:ex/room-116-out",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-533-air-in"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-533-discharge-air-flow"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/zone-111-temp-sensor",
+ "@id": "urn:ex/zone-109-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-111-hvac-domain"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/zone-111-temp"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-505-discharge-air-temp-sensor",
+ "@id": "urn:ex/vav-540-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/vav-505-air-out"
+ "@id": "urn:ex/vav-540-damper"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/vav-505-discharge-air-temp"
+ "@id": "urn:ex/vav-540-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-533-hot-water-in",
+ "@id": "urn:ex/vav-530-reheat-coil-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-533-hot-water-in-connection"
+ "@id": "urn:ex/vav-530-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/zone-112-114-occupancy-sensor",
+ "@id": "urn:ex/vav-517-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-112-hvac-domain"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-112-114-occupancy"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/zone-115-occupancy-override",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "urn:ex/vav-517-air-in"
}
]
},
{
- "@id": "urn:ex/vav-519-reheat-coil",
+ "@id": "urn:ex/office-ahu-sa-fan-out",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-519-reheat-coil-air-in"
- },
- {
- "@id": "urn:ex/vav-519-reheat-coil-air-out"
- },
- {
- "@id": "urn:ex/vav-519-reheat-coil-water-in"
- },
- {
- "@id": "urn:ex/vav-519-reheat-coil-water-out"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/vav-519-duct-after-damper",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/office-ahu-sa-out"
}
]
},
{
- "@id": "urn:ex/vav-504-reheat-coil-valve-in",
+ "@id": "urn:ex/room-207-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-504-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-503-duct-after-damper",
+ "@id": "urn:ex/zone-110-occupancy-override",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
]
},
{
- "@id": "urn:ex/vav-511-damper-position",
+ "@id": "urn:ex/vav-516-damper-command",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -37379,111 +37396,94 @@
]
},
{
- "@id": "urn:ex/vav-537-reheat-coil",
+ "@id": "urn:ex/vav-528-pipe-hot-water-return-before-valve",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-537-reheat-coil-air-in"
- },
- {
- "@id": "urn:ex/vav-537-reheat-coil-air-out"
- },
- {
- "@id": "urn:ex/vav-537-reheat-coil-water-in"
- },
- {
- "@id": "urn:ex/vav-537-reheat-coil-water-out"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/zone-108-occupancy-override",
+ "@id": "urn:ex/vav-501-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "urn:ex/vav-501-air-in"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:ex/vav-501-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/room-311-hvac-domain",
+ "@id": "urn:ex/vav-512-cooling-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/room-311-in"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-311-out"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/zone-108",
+ "@id": "urn:ex/vav-536",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
- ],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/room-108-hvac-domain"
- }
- ],
- "http://data.ashrae.org/standard223#hasDomain": [
- {
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
- }
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/zone-108-cooling-setpoint"
+ "@id": "urn:ex/vav-536-air-in"
},
{
- "@id": "urn:ex/zone-108-heating-setpoint"
+ "@id": "urn:ex/vav-536-air-out"
},
{
- "@id": "urn:ex/zone-108-occupancy"
+ "@id": "urn:ex/vav-536-hot-water-in"
},
{
- "@id": "urn:ex/zone-108-occupancy-override"
+ "@id": "urn:ex/vav-536-hot-water-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#contains": [
+ {
+ "@id": "urn:ex/vav-536-damper"
},
{
- "@id": "urn:ex/zone-108-temp"
+ "@id": "urn:ex/vav-536-reheat-coil"
},
{
- "@id": "urn:ex/zone-108-window-switch-on-off"
+ "@id": "urn:ex/vav-536-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/room-115-out",
+ "@id": "urn:ex/zone-201-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/room-201-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/zone-201-temp"
}
]
}
diff --git a/models/nist-example.jsonld b/models/nist-example.jsonld
index 904f856c..82d6fe63 100644
--- a/models/nist-example.jsonld
+++ b/models/nist-example.jsonld
@@ -1,73 +1,132 @@
[
{
- "@id": "http://example.org/IBAL#Channel_105",
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_4_ICP_1",
"@type": [
- "http://data.ashrae.org/standard223#TemperatureSensor"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#HVAC_Space_1_ICP"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
{
- "@id": "http://example.org/IBAL#zs1_heat_rtd"
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_4"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 105"
+ "@value": "Motorized three way valve 4 ICP 1"
}
]
},
{
- "@id": "http://example.org/IBAL#HVACSpace_1",
+ "@id": "http://example.org/IBAL#Damper_3_OCP",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#HVAC_Space_1_ICP"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Damper 3 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#d11_pos_fb",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/PositionVector"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "d11 pos fb"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_27",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Fan_3_ICP"
},
{
- "@id": "http://example.org/IBAL#HVAC_Space_1_OCP"
+ "@id": "http://example.org/IBAL#Jnc9-OCP2"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://example.org/IBAL#zs1_t_sp_f"
+ "@value": "Segment 27"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc25-ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "HVACSpace 1"
+ "@value": "Jnc25-ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#d16_pos_c",
+ "@id": "http://example.org/IBAL#AHU_1_ICP",
"@type": [
- "http://data.ashrae.org/bacnet/2020#AnalogOutputObject",
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "AHU 1 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#vav2_heat_c",
+ "@type": [
+ "http://data.ashrae.org/standard223#AnalogOutputObject",
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://data.ashrae.org/bacnet/2020#description": [
{
- "@value": "VAV2 Damper Control Signal"
+ "@value": "VAV1 Heater Control Signal"
}
],
"http://data.ashrae.org/bacnet/2020#object-identifier": [
{
- "@value": "analog-output,2"
+ "@value": "analog-output,1"
}
],
"http://data.ashrae.org/bacnet/2020#object-name": [
{
- "@value": "d16_pos_c"
+ "@value": "vav2_heat_c"
}
],
"http://data.ashrae.org/bacnet/2020#object-type": [
@@ -88,28 +147,34 @@
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
+ "@id": "http://qudt.org/vocab/quantitykind/Voltage"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/A"
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "d16 pos c"
+ "@value": "vav2 heat c"
}
]
},
{
- "@id": "http://example.org/IBAL#Damper_11_ICP",
+ "@id": "http://example.org/IBAL#Junction_17",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Junction"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Segment_39"
+ "@id": "http://example.org/IBAL#Jnc17-ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc17-ICP2"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc17-OCP"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -119,51 +184,75 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Damper 11 ICP"
+ "@value": "Junction 17"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_159",
+ "@id": "http://example.org/IBAL#HC-5-OutletFlow",
"@type": [
- "http://data.ashrae.org/standard223#TemperatureSensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasValue": [
{
- "@id": "http://example.org/IBAL#Segment_92"
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "20"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://example.org/IBAL#pl_out_rtd"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "20"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 159"
+ "@value": "HC 5 OutletFlow"
}
]
},
{
- "@id": "http://example.org/IBAL#HC_3_W_ICP",
+ "@id": "http://example.org/IBAL#ahu2_heat_power",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/W"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "HC 3 W ICP"
+ "@value": "ahu2 heat power"
}
]
},
{
- "@id": "http://example.org/IBAL#HC_1_OCP",
+ "@id": "http://example.org/IBAL#AHU_2_Connection_2",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#connectsAt": [
+ {
+ "@id": "http://example.org/IBAL#CC_2_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_4_OCP"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -172,186 +261,178 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "HC 1 OCP"
+ "@value": "AHU 2 Connection 2"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_60",
+ "@id": "http://example.org/IBAL#Junction_12",
"@type": [
- "http://data.ashrae.org/standard223#ElectricMeter"
+ "http://data.ashrae.org/standard223#Junction"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#VFD_1"
+ "@id": "http://example.org/IBAL#Jnc12-ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc12-OCP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc12-OCP2"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#ahu2_fan_power"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 60"
+ "@value": "Junction 12"
}
]
},
{
- "@id": "http://example.org/IBAL#WaterPump_1",
+ "@id": "http://example.org/IBAL#MotorizedDamper_14",
"@type": [
- "http://data.ashrae.org/standard223#Pump"
+ "http://data.ashrae.org/standard223#Damper"
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://example.org/IBAL#WaterPump_1_ICP"
+ "@id": "http://example.org/IBAL#Damper_14_ICP"
},
{
- "@id": "http://example.org/IBAL#WaterPump_1_OCP"
+ "@id": "http://example.org/IBAL#Damper_14_OCP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Water pump 1"
+ "@value": "Motorized damper 14"
}
]
},
{
- "@id": "http://example.org/IBAL#Junction_1",
+ "@id": "http://example.org/IBAL#Segment_98",
"@type": [
- "http://data.ashrae.org/standard223#Junction"
+ "http://data.ashrae.org/standard223#Connection"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Jnc1-ICP"
- },
- {
- "@id": "http://example.org/IBAL#Jnc1-OCP1"
+ "@id": "http://example.org/IBAL#Jnc22-ICP"
},
{
- "@id": "http://example.org/IBAL#Jnc1-OCP2"
+ "@id": "http://example.org/IBAL#Jnc36-OCP2"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Junction 1"
+ "@value": "Segment 98"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_334T",
+ "@id": "http://example.org/IBAL#ahu1_heat_c",
"@type": [
- "http://data.ashrae.org/standard223#TemperatureSensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://example.org/IBAL#Segment_20"
+ "@id": "http://qudt.org/vocab/quantitykind/Voltage"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://example.org/IBAL#ahu2_t_ra"
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 334T"
+ "@value": "AHU1 Heat C"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc32-OCP",
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_2_OCP",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#Segment_88"
- }
- ],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc32-OCP"
+ "@value": "Manual two way valve 2 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc2-ICP",
+ "@id": "http://example.org/IBAL#Jnc22-OCP1",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc2-ICP"
+ "@value": "Jnc22-OCP1"
}
]
},
{
- "@id": "http://example.org/IBAL#VAV_4",
+ "@id": "http://example.org/IBAL#PlateHeatExchange_1_Upper_OCP",
"@type": [
- "http://data.ashrae.org/bacnet/2020#BACnetDevice",
- "http://data.ashrae.org/standard223#TerminalUnit"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/bacnet/2020#hasPort": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/bacnet/2020#P_47814"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "http://example.org/IBAL#HeatingCoil_6"
- },
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://example.org/IBAL#MotorizedDamper_4"
+ "@value": "Plate Heat Exchange 1 Upper OCP"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc29-OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "http://example.org/IBAL#VAV_4_ICP"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#VAV_4_OCP"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "VAV 4"
+ "@value": "Jnc29-OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_124",
+ "@id": "http://example.org/IBAL#Fan_4_ICP",
"@type": [
- "http://data.ashrae.org/standard223#TemperatureSensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "http://example.org/IBAL#Segment_105"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#ahu1_cc_out_rtd"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 124"
+ "@value": "Fan 4 ICP"
}
]
},
@@ -372,228 +453,224 @@
]
},
{
- "@id": "http://example.org/IBAL#zs4_t_sp_f",
+ "@id": "http://example.org/IBAL#HeatExchange",
"@type": [
- "http://data.ashrae.org/bacnet/2020#AnalogInputObject",
- "http://data.ashrae.org/standard223#QuantifiableProperty"
- ],
- "http://data.ashrae.org/bacnet/2020#description": [
- {
- "@value": "Zone4 Temperature Setpoint"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/bacnet/2020#object-identifier": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@value": "analog-input,6"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/bacnet/2020#object-name": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@value": "zs4_t_sp_f"
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
}
],
- "http://data.ashrae.org/bacnet/2020#object-type": [
+ "http://qudt.org/schema/qudt/value": [
{
- "@value": "analog-input"
+ "@value": "60"
}
],
- "http://data.ashrae.org/bacnet/2020#objectOf": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://example.org/IBAL#VAV_4"
+ "@value": "HeatExchange"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_35",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/bacnet/2020#present-value": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@type": "http://www.w3.org/2001/XMLSchema#float",
- "@value": "74.0"
+ "@id": "http://example.org/IBAL#Jnc13-ICP1"
}
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Aspect-Setpoint"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@value": "Segment 35"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc31-OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_F"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "zs4 t sp f"
+ "@value": "Jnc31-OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#d5_pos_fb",
+ "@id": "http://example.org/IBAL#HC_6_ICP",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositionVector"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "d5 pos fb"
+ "@value": "HC 6 ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#MotorizedDamper_6",
+ "@id": "http://example.org/IBAL#VFD_5_OCP",
"@type": [
- "http://data.ashrae.org/standard223#Damper"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "http://example.org/IBAL#Damper_6_ICP"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#Damper_6_OCP"
+ "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Motorized damper 6"
+ "@value": "VFD 5 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#exf2_f",
+ "@id": "http://example.org/IBAL#Jnc5-ICP1",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "exf2 f"
+ "@value": "Jnc5-ICP1"
}
]
},
{
- "@id": "http://example.org/IBAL#ahu1_heat_power",
+ "@id": "http://example.org/IBAL#Jnc24-ICP",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ "@id": "http://example.org/IBAL#Segment_67"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/W"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "AHU1 Heat Power"
+ "@value": "Jnc24-ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#HeatingCoil_6",
+ "@id": "http://example.org/IBAL#Segment_24",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil"
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "http://example.org/IBAL#HC_6_E_ICP"
- },
- {
- "@id": "http://example.org/IBAL#HC_6_ICP"
- },
- {
- "@id": "http://example.org/IBAL#HC_6_OCP"
- },
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#HC_6_W_ICP"
+ "@id": "http://example.org/IBAL#Damper_8_ICP"
},
{
- "@id": "http://example.org/IBAL#HC_6_W_OCP"
+ "@id": "http://example.org/IBAL#Jnc8-OCP2"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@value": "IBAL:VAV4_OCP"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Heating coil 6"
+ "@value": "Segment 24"
}
]
},
{
- "@id": "http://example.org/IBAL#d17_pos_fb",
+ "@id": "http://example.org/IBAL#Jnc2-OCP2",
"@type": [
- "http://data.ashrae.org/bacnet/2020#AnalogInputObject",
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/bacnet/2020#description": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@value": "VAV3 Damper Feedback Signal"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/bacnet/2020#object-identifier": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "analog-input,1"
+ "@value": "Jnc2-OCP2"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_3_VFD_3",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/bacnet/2020#object-name": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@value": "d17_pos_fb"
- }
- ],
- "http://data.ashrae.org/bacnet/2020#object-type": [
+ "@id": "http://example.org/IBAL#Fan_3_E_ICP"
+ },
{
- "@value": "analog-input"
+ "@id": "http://example.org/IBAL#VFD_3_OCP"
}
],
- "http://data.ashrae.org/bacnet/2020#objectOf": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#VAV_3"
+ "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
}
],
- "http://data.ashrae.org/bacnet/2020#present-value": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@type": "http://www.w3.org/2001/XMLSchema#float",
- "@value": "0.0"
+ "@value": "Fan 3 VFD 3"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Channel_111",
+ "@type": [
+ "http://data.ashrae.org/standard223#TemperatureSensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Voltage"
+ "@id": "http://example.org/IBAL#HVAC_Space_4_ICP"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "http://example.org/IBAL#zs4_heat_rtd"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "d17 pos fb"
+ "@value": "Channel 111"
}
]
},
{
- "@id": "http://example.org/IBAL#Fan_4_OCP",
+ "@id": "http://example.org/IBAL#Damper_9_OCP",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -602,412 +679,528 @@
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_9"
+ }
+ ],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Fan 4 OCP"
+ "@value": "Damper 9 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_30",
+ "@id": "http://example.org/IBAL#Channel_51",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#HumiditySensor"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#Fan_4_ICP"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#Jnc10-OCP"
+ "@id": "http://example.org/IBAL#Segment_44"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://example.org/IBAL#oau_rh"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 30"
+ "@value": "Channel 51"
}
]
},
{
- "@id": "http://example.org/IBAL#Chiller_2_Lower_OCP",
+ "@id": "http://example.org/IBAL#ahu2_vfd",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/bacnet/2020#AnalogOutputObject",
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/bacnet/2020#description": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@value": "AHU2 Fan Speed"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/bacnet/2020#object-identifier": [
{
- "@value": "Chiller 2 Lower OCP"
+ "@value": "analog-output,1"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#ch1_e_in_rtd",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/bacnet/2020#object-name": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@value": "ahu1_vfd"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/bacnet/2020#object-type": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_F"
+ "@value": "analog-output"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/bacnet/2020#objectOf": [
{
- "@value": "ch1 e in rtd"
+ "@id": "http://example.org/IBAL#AHU_1"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#Jnc28-ICP",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/bacnet/2020#present-value": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@type": "http://www.w3.org/2001/XMLSchema#float",
+ "@value": "30.0"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Voltage"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc28-ICP"
+ "@value": "ahu2 vfd"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc30-OCP",
+ "@id": "http://example.org/IBAL#WaterPump_3_OCP",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#Segment_84"
- }
- ],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc30-OCP"
+ "@value": "Water pump 3 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_128",
+ "@id": "http://example.org/IBAL#Fan_3_OCP",
"@type": [
- "http://data.ashrae.org/standard223#TemperatureSensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "http://example.org/IBAL#Segment_67"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#sl_out_rtd"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 128"
+ "@value": "Fan 3 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_82",
+ "@id": "http://example.org/IBAL#HeatingCoil_3",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#HeatingCoil"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://example.org/IBAL#Jnc30-ICP"
+ "@id": "http://example.org/IBAL#HC_3_E_ICP"
},
{
- "@id": "http://example.org/IBAL#WaterPump_3_OCP"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "http://example.org/IBAL#HC_3_ICP"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://example.org/IBAL#HC_3_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_3_W_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_3_W_OCP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 82"
+ "@value": "Heating coil 3"
}
]
},
{
- "@id": "http://example.org/IBAL#Chiller_2_Lower_ICP",
+ "@id": "http://example.org/IBAL#VFD_5_ICP",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Chiller 2 Lower ICP"
+ "@value": "VFD 5 ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#HVACZone_4",
+ "@id": "http://example.org/IBAL#ahu2_cc_out_rtd",
"@type": [
- "http://data.ashrae.org/standard223#Zone"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasDomainSpace": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://example.org/IBAL#HVACSpace_4"
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "HVACZone 4"
+ "@value": "ahu2 cc out rtd"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_397",
+ "@id": "http://example.org/IBAL#Channel_6",
"@type": [
- "http://data.ashrae.org/standard223#Controller"
+ "http://data.ashrae.org/standard223#HumiditySensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#HeatingCoil_4"
+ "@id": "http://example.org/IBAL#Segment_9"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#ahu1_heat_c"
+ "@id": "http://example.org/IBAL#ahu1_rh_down"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 397"
+ "@value": "Channel 6"
}
]
},
{
- "@id": "http://example.org/IBAL#Damper_17_OCP",
+ "@id": "http://example.org/IBAL#Channel_200",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#MotorizedDamper_17"
- }
+ "http://data.ashrae.org/standard223#FlowSensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://example.org/IBAL#Segment_69"
}
],
- "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#MotorizedDamper_17"
+ "@id": "http://example.org/IBAL#pl_f"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Damper 17 OCP"
+ "@value": "Channel 200"
}
]
},
{
- "@id": "http://example.org/IBAL#Enclosure_3",
+ "@id": "http://example.org/IBAL#Channel_197",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#FlowSensor"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#HVACSpace_3"
+ "@id": "http://example.org/IBAL#Segment_105"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#ahu1_f_cc"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Enclosure 3"
+ "@value": "Channel 197"
}
]
},
{
- "@id": "http://example.org/IBAL#VAV_3_ICP",
+ "@id": "http://example.org/IBAL#Jnc33-OCP2",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "VAV 3 ICP"
+ "@value": "Jnc33-OCP2"
}
]
},
{
- "@id": "http://example.org/IBAL#WaterPump_3_ICP",
+ "@id": "http://example.org/IBAL#Channel_310",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Controller"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://example.org/IBAL#MotorizedDamper_14"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#d5_pos_fb"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Water pump 3 ICP"
+ "@value": "Channel 310"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc36-ICP",
+ "@id": "http://example.org/IBAL#HeatingCoil_1",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#HeatingCoil"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://example.org/IBAL#HC_1_E_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_1_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_1_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_1_W_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_1_W_OCP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc36-ICP"
+ "@value": "Heating coil 1"
}
]
},
{
- "@id": "http://example.org/IBAL#Fan_4_VFD_4",
+ "@id": "http://example.org/IBAL#AHU_3",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#AirHandlingUnit"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://example.org/IBAL#Fan_4_E_ICP"
+ "@id": "http://example.org/IBAL#CoolingCoil_3"
},
{
- "@id": "http://example.org/IBAL#VFD_4_OCP"
+ "@id": "http://example.org/IBAL#Fan_5"
+ },
+ {
+ "@id": "http://example.org/IBAL#HeatingCoil_7"
+ },
+ {
+ "@id": "http://example.org/IBAL#VFD_5"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
+ "@id": "http://example.org/IBAL#AHU_3_G_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#AHU_3_G_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#AHU_3_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#AHU_3_OCP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Fan 4 VFD 4"
+ "@value": "AHU 3"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_48",
+ "@id": "http://example.org/IBAL#AHU2_FnB",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#FunctionBlock"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasInput": [
{
- "@id": "http://example.org/IBAL#Damper_17_ICP"
+ "@id": "http://example.org/IBAL#ahu1_out_rtd"
},
{
- "@id": "http://example.org/IBAL#Jnc16-OCP1"
+ "@id": "http://example.org/IBAL#ahu1_p_down"
+ },
+ {
+ "@id": "http://example.org/IBAL#d17_pos_c"
+ },
+ {
+ "@id": "http://example.org/IBAL#d18_pos_c"
+ },
+ {
+ "@id": "http://example.org/IBAL#v12_pos_fb"
+ },
+ {
+ "@id": "http://example.org/IBAL#vav3_heat_c"
+ },
+ {
+ "@id": "http://example.org/IBAL#vav4_heat_c"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasOutput": [
+ {
+ "@id": "http://example.org/IBAL#ahu1_vfd"
+ },
+ {
+ "@id": "http://example.org/IBAL#v12_pos_c"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "AHU2 Fn b"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_6_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "http://example.org/IBAL#VAV_4_OCP"
+ }
+ ],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 48"
+ "@value": "HC 6 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#ahu1_rh_up",
+ "@id": "http://example.org/IBAL#ahu1_f_sa",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://data.ashrae.org/standard223#hasValue": [
{
"@type": "http://www.w3.org/2001/XMLSchema#decimal",
- "@value": "60"
+ "@value": "600"
}
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://qudt.org/schema/qudt/value": [
{
- "@value": "60"
+ "@value": "600"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "AHU 1 RH Up"
+ "@value": "AHU 1 F SA"
}
]
},
{
- "@id": "http://example.org/IBAL#Junction_6",
+ "@id": "http://example.org/IBAL#Channel_14",
"@type": [
- "http://data.ashrae.org/standard223#Junction"
+ "http://data.ashrae.org/standard223#PressureSensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#Jnc6-ICP1"
- },
+ "@id": "http://example.org/IBAL#Exhaust_Fan_1_Connection_2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#Jnc6-ICP2"
- },
+ "@id": "http://example.org/IBAL#exf1_p_down"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://example.org/IBAL#Jnc6-OCP"
+ "@value": "Channel 14"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_18_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_18"
+ }
+ ],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Junction 6"
+ "@value": "Damper 18 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc4-ICP",
+ "@id": "http://example.org/IBAL#Hydronic",
+ "@type": [
+ "http://data.ashrae.org/standard223#System"
+ ],
+ "http://data.ashrae.org/standard223#hasMember": [
+ {
+ "@id": "http://example.org/IBAL#CoolingCoil_1"
+ },
+ {
+ "@id": "http://example.org/IBAL#CoolingCoil_2"
+ },
+ {
+ "@id": "http://example.org/IBAL#PlateHeatExchanger_1"
+ },
+ {
+ "@id": "http://example.org/IBAL#PlateHeatExchanger_2"
+ },
+ {
+ "@id": "http://example.org/IBAL#ThermalStorage_1"
+ },
+ {
+ "@id": "http://example.org/IBAL#WaterChiller_1"
+ },
+ {
+ "@id": "http://example.org/IBAL#WaterChiller_2"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Hydronic"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_16_ICP",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -1016,35 +1209,40 @@
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_16"
+ }
+ ],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc4-ICP"
+ "@value": "Damper 16 ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#CC_2_Water_OCP",
+ "@id": "http://example.org/IBAL#Channel_363AO",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Controller"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://example.org/IBAL#MotorizedDamper_3"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#AHU_2_G_OCP"
+ "@id": "http://example.org/IBAL#d17_pos_c"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": " CC 2 Water OCP"
+ "@value": "Channel 363AO"
}
]
},
{
- "@id": "http://example.org/IBAL#PlateHeatExchange_2_Upper_OCP",
+ "@id": "http://example.org/IBAL#Jnc4-OCP2",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -1055,24 +1253,24 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Plate Heat Exchange 2 Upper OCP"
+ "@value": "Jnc4-OCP2"
}
]
},
{
- "@id": "http://example.org/IBAL#Junction_11",
+ "@id": "http://example.org/IBAL#Junction_2",
"@type": [
"http://data.ashrae.org/standard223#Junction"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Jnc11-ICP1"
+ "@id": "http://example.org/IBAL#Jnc2-ICP"
},
{
- "@id": "http://example.org/IBAL#Jnc11-ICP2"
+ "@id": "http://example.org/IBAL#Jnc2-OCP"
},
{
- "@id": "http://example.org/IBAL#Jnc11-OCP"
+ "@id": "http://example.org/IBAL#Jnc2-OCP2"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -1082,114 +1280,83 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Junction 11"
+ "@value": "Junction 2"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc37-OCP2",
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_1_OCP",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc37-OCP2"
+ "@value": "Manual two way valve 1 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#AHU_1_G_ICP",
+ "@id": "http://example.org/IBAL#CC_1_Bypass_Connection",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#connectsAt": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_2_OCP"
+ },
{
- "@value": "AHU 1 G ICP"
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_1_ICP_2"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#HeatingCoil_4",
- "@type": [
- "http://data.ashrae.org/standard223#HeatingCoil"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "http://example.org/IBAL#HC_4_E_ICP"
- },
- {
- "@id": "http://example.org/IBAL#HC_4_ICP"
- },
- {
- "@id": "http://example.org/IBAL#HC_4_OCP"
- },
- {
- "@id": "http://example.org/IBAL#HC_4_W_ICP"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#HC_4_W_OCP"
+ "@id": "http://data.ashrae.org/standard223#Water-ChilledWater"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Heating coil 4"
+ "@value": "CC 1 Bypass Connection"
}
]
},
{
- "@id": "http://example.org/IBAL#ahu2_f_ra",
+ "@id": "http://example.org/IBAL#VAV_1_OCP",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://example.org/IBAL#VAV_1_Connection_2"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "ahu2 f ra"
+ "@value": "VAV 1 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#MotorizedDamper_8",
+ "@id": "http://example.org/IBAL#Segment_62",
"@type": [
- "http://data.ashrae.org/standard223#Damper"
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Damper_8_ICP"
+ "@id": "http://example.org/IBAL#Jnc21-OCP"
},
{
- "@id": "http://example.org/IBAL#Damper_8_OCP"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "Motorized damper 8"
+ "@id": "http://example.org/IBAL#Jnc23-ICP"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#PlateHeatExchange_2_Lower_ICP",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -1198,85 +1365,71 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Plate Heat Exchange 2 Lower ICP"
+ "@value": "Segment 62"
}
]
},
{
- "@id": "http://example.org/IBAL#Fan_4_ICP",
+ "@id": "http://example.org/IBAL#vav3_f",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/bacnet/2020#AnalogInputObject",
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/bacnet/2020#description": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@value": "VAV3 Airflow Rate"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/bacnet/2020#object-identifier": [
{
- "@value": "Fan 4 ICP"
+ "@value": "analog-input,4"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#ahu1_cc_rtd",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasValue": [
+ "http://data.ashrae.org/bacnet/2020#object-name": [
{
- "@type": "http://www.w3.org/2001/XMLSchema#decimal",
- "@value": "45"
+ "@value": "vav3_f"
}
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/bacnet/2020#object-type": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@value": "analog-input"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/bacnet/2020#objectOf": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_F"
+ "@id": "http://example.org/IBAL#VAV_3"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/bacnet/2020#present-value": [
{
- "@value": "AHU 1 CC RTD"
+ "@type": "http://www.w3.org/2001/XMLSchema#float",
+ "@value": "0.0"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#Channel_198",
- "@type": [
- "http://data.ashrae.org/standard223#FlowSensor"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://example.org/IBAL#Segment_106"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://example.org/IBAL#ahu2_f_cc_mag"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 198"
+ "@value": "vav3 f"
}
]
},
{
- "@id": "http://example.org/IBAL#AHU_1_Connection_3",
+ "@id": "http://example.org/IBAL#Damper_11_ICP",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#connectsAt": [
- {
- "@id": "http://example.org/IBAL#CC_1_OCP"
- },
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Fan_1_ICP"
+ "@id": "http://example.org/IBAL#Segment_39"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -1286,334 +1439,371 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "AHU 1 Connection 3"
+ "@value": "Damper 11 ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#vav3_heat_c",
+ "@id": "http://example.org/IBAL#oau_rh",
"@type": [
- "http://data.ashrae.org/standard223#AnalogOutputObject",
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/bacnet/2020#description": [
- {
- "@value": "VAV3 Heater Control Signal"
- }
- ],
- "http://data.ashrae.org/bacnet/2020#object-identifier": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@value": "analog-output,1"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
}
],
- "http://data.ashrae.org/bacnet/2020#object-name": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@value": "vav3_heat_c"
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
- "http://data.ashrae.org/bacnet/2020#object-type": [
+ "http://qudt.org/schema/qudt/value": [
{
- "@value": "analog-output"
+ "@value": "80"
}
],
- "http://data.ashrae.org/bacnet/2020#objectOf": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://example.org/IBAL#VAV_3"
+ "@value": "oau rh"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_17_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/bacnet/2020#present-value": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@type": "http://www.w3.org/2001/XMLSchema#float",
- "@value": "0.0"
+ "@id": "http://example.org/IBAL#MotorizedDamper_17"
}
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Voltage"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "http://example.org/IBAL#MotorizedDamper_17"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "vav3 heat c"
+ "@value": "Damper 17 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_193",
+ "@id": "http://example.org/IBAL#Channel_159",
"@type": [
- "http://data.ashrae.org/standard223#FlowSensor"
+ "http://data.ashrae.org/standard223#TemperatureSensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#Chiller_1_Lower_Connection"
+ "@id": "http://example.org/IBAL#Segment_92"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#ch1_f_e"
+ "@id": "http://example.org/IBAL#pl_out_rtd"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 193"
+ "@value": "Channel 159"
}
]
},
{
- "@id": "http://example.org/IBAL#CC_1_Water_OCP",
+ "@id": "http://example.org/IBAL#VAV3_FnB",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#FunctionBlock"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasInput": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://example.org/IBAL#d17_pos_fb"
+ },
+ {
+ "@id": "http://example.org/IBAL#vav3_f"
+ },
+ {
+ "@id": "http://example.org/IBAL#vav3_out_rtd"
+ },
+ {
+ "@id": "http://example.org/IBAL#vav3_t_in"
+ },
+ {
+ "@id": "http://example.org/IBAL#zs3_out_rtd"
+ },
+ {
+ "@id": "http://example.org/IBAL#zs3_t_sp_f"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasOutput": [
{
- "@id": "http://example.org/IBAL#AHU_1_G_OCP"
+ "@id": "http://example.org/IBAL#d17_pos_c"
+ },
+ {
+ "@id": "http://example.org/IBAL#vav3_heat_c"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": " CC 1 Water OCP"
+ "@value": "VAV3 Fn b"
}
]
},
{
- "@id": "http://example.org/IBAL#CC_2_Water_ICP",
+ "@id": "http://example.org/IBAL#MotorizedDamper_15",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Damper"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://example.org/IBAL#Damper_15_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_15_OCP"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://example.org/IBAL#AHU_2_G_ICP"
+ "@value": "Motorized damper 15"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_11",
+ "@type": [
+ "http://data.ashrae.org/standard223#Damper"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#Damper_11_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_11_OCP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "CC 2 Water ICP"
+ "@value": "Motorized damper 11"
}
]
},
{
- "@id": "http://example.org/IBAL#Chiller_2_Upper_ICP",
+ "@id": "http://example.org/IBAL#AHU_3_G_ICP",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Chiller 2 Upper ICP"
+ "@value": "AHU 3 G ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#oau_in_rtd",
+ "@id": "http://example.org/IBAL#Jnc22-OCP2",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc22-OCP2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#exf1_p_down",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_F"
+ "@id": "http://qudt.org/vocab/unit/PA"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "oau in rtd"
+ "@value": "exf1 p down"
}
]
},
{
- "@id": "http://example.org/IBAL#ahu1_heat_rtd",
+ "@id": "http://example.org/IBAL#zs3_rh",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
+ "http://data.ashrae.org/standard223#hasValue": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "50"
+ }
+ ],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_F"
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "AHU 1 Heat RTD"
+ "@value": "zs3 rh"
}
]
},
{
- "@id": "http://example.org/IBAL#MotorizedDamper_10",
+ "@id": "http://example.org/IBAL#AHU_2_G_ICP",
"@type": [
- "http://data.ashrae.org/standard223#Damper"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Damper_10_ICP"
- },
+ "@id": "http://example.org/IBAL#Segment_56"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#Damper_10_OCP"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Motorized damper 10"
+ "@value": "AHU 2 G ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_52",
+ "@id": "http://example.org/IBAL#Jnc3-ICP1",
"@type": [
- "http://data.ashrae.org/standard223#ElectricMeter"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "http://example.org/IBAL#WaterChiller_1"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#ch1_power"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 52"
+ "@value": "Jnc3-ICP1"
}
]
},
{
- "@id": "http://example.org/IBAL#ahu2_out_rtd",
+ "@id": "http://example.org/IBAL#zs4_heat_rtd",
"@type": [
- "http://data.ashrae.org/bacnet/2020#AnalogInputObject",
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/bacnet/2020#description": [
+ "http://data.ashrae.org/standard223#hasValue": [
{
- "@value": "AHU2 Supply Air Temperature"
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "68"
}
],
- "http://data.ashrae.org/bacnet/2020#object-identifier": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@value": "analog-input,2"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/bacnet/2020#object-name": [
- {
- "@value": "ahu2_out_rtd"
- }
- ],
- "http://data.ashrae.org/bacnet/2020#object-type": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@value": "analog-input"
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
}
],
- "http://data.ashrae.org/bacnet/2020#objectOf": [
+ "http://qudt.org/schema/qudt/value": [
{
- "@id": "http://example.org/IBAL#AHU_1"
+ "@value": "68"
}
],
- "http://data.ashrae.org/bacnet/2020#present-value": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@type": "http://www.w3.org/2001/XMLSchema#float",
- "@value": "70.0"
+ "@value": "zs4 heat rtd"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_2_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_F"
+ "@id": "http://example.org/IBAL#AHU_2_OCP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "ahu2 out rtd"
+ "@value": "Fan 2 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_4_ICP_1",
+ "@id": "http://example.org/IBAL#Chiller_1_Lower_OCP",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ],
- "http://data.ashrae.org/standard223#isConnectionPointOf": [
- {
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_4"
+ "@id": "http://data.ashrae.org/standard223#Water-ChilledWater"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Motorized three way valve 4 ICP 1"
+ "@value": "Chiller 1 Lower OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_126",
+ "@id": "http://example.org/IBAL#Channel_62",
"@type": [
- "http://data.ashrae.org/standard223#TemperatureSensor"
+ "http://data.ashrae.org/standard223#ElectricMeter"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#Segment_88"
+ "@id": "http://example.org/IBAL#HeatingCoil_1"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#ts_in_rtd"
+ "@id": "http://example.org/IBAL#ahu2_heat_power"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 126"
+ "@value": "Channel 62"
}
]
},
{
- "@id": "http://example.org/IBAL#Junction_22",
+ "@id": "http://example.org/IBAL#Jnc18-OCP2",
"@type": [
- "http://data.ashrae.org/standard223#Junction"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#Jnc22-ICP"
- },
- {
- "@id": "http://example.org/IBAL#Jnc22-OCP1"
- },
- {
- "@id": "http://example.org/IBAL#Jnc22-OCP2"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -1622,63 +1812,84 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Junction 22"
+ "@value": "Jnc18-OCP2"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc6-ICP1",
+ "@id": "http://example.org/IBAL#Channel_72",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#ElectricMeter"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://example.org/IBAL#VFD_4"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#exf2_power"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc6-ICP1"
+ "@value": "Channel 72"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_46",
+ "@id": "http://example.org/IBAL#zs2_heat_rtd",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasValue": [
{
- "@id": "http://example.org/IBAL#Damper_16_ICP"
- },
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "70"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://example.org/IBAL#Jnc15-OCP2"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "70"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 46"
+ "@value": "zs2 heat rtd"
}
]
},
{
- "@id": "http://example.org/IBAL#PlateHeatExchange_1_Lower_OCP",
+ "@id": "http://example.org/IBAL#Chiller_2_Lower_Connection",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#connectsAt": [
+ {
+ "@id": "http://example.org/IBAL#Chiller_2_Lower_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#WaterPump_3_ICP"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Water-ChilledWater"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Plate Heat Exchange 1 Lower OCP"
+ "@value": "Chiller 2 Lower Connection"
}
]
},
@@ -1704,328 +1915,295 @@
]
},
{
- "@id": "http://example.org/IBAL#Channel_303T",
+ "@id": "http://example.org/IBAL#Damper_4_ICP",
"@type": [
- "http://data.ashrae.org/standard223#TemperatureSensor"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#Segment_7"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://example.org/IBAL#vav3_t_in"
+ "@id": "http://example.org/IBAL#VAV_4_ICP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 303T"
+ "@value": "Damper 4 ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_47",
+ "@id": "http://example.org/IBAL#exf2_f",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#Damper_16_OCP"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://example.org/IBAL#Jnc16-ICP"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 47"
+ "@value": "exf2 f"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_44",
+ "@id": "http://example.org/IBAL#d16_pos_fb",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#Jnc15-ICP"
- }
+ "http://data.ashrae.org/bacnet/2020#AnalogInputObject",
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/bacnet/2020#description": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@value": "VAV2 Damper Feedback Signal"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/bacnet/2020#object-identifier": [
{
- "@value": "Segment 44"
+ "@value": "analog-input,1"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#Damper_2_OCP",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/bacnet/2020#object-name": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@value": "d16_pos_fb"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/bacnet/2020#object-type": [
{
- "@value": "Damper 2 OCP"
+ "@value": "analog-input"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#CC_3_ICP",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/bacnet/2020#objectOf": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://example.org/IBAL#VAV_2"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/bacnet/2020#present-value": [
{
- "@id": "http://example.org/IBAL#AHU_3_ICP"
+ "@type": "http://www.w3.org/2001/XMLSchema#float",
+ "@value": "0.0"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@value": "CC 3 ICP"
+ "@id": "http://qudt.org/vocab/quantitykind/Voltage"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#Jnc20-ICP",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc20-ICP"
+ "@value": "d16 pos fb"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc27-OCP1",
+ "@id": "http://example.org/IBAL#d15_pos_c",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/bacnet/2020#AnalogOutputObject",
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/bacnet/2020#description": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@value": "VAV1 Damper Control Signal"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/bacnet/2020#object-identifier": [
{
- "@value": "Jnc27-OCP1"
+ "@value": "analog-output,2"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#Exhaust_Fan_1_Connection_2",
- "@type": [
- "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/standard223#connectsAt": [
- {
- "@id": "http://example.org/IBAL#Damper_7_ICP"
- },
+ "http://data.ashrae.org/bacnet/2020#object-name": [
{
- "@id": "http://example.org/IBAL#Fan_3_OCP"
+ "@value": "d15_pos_c"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/bacnet/2020#object-type": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@value": "analog-output"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/bacnet/2020#objectOf": [
{
- "@value": "Exhaust Fan 1 Connection 2"
+ "@id": "http://example.org/IBAL#VAV_1"
+ }
+ ],
+ "http://data.ashrae.org/bacnet/2020#present-value": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#float",
+ "@value": "0.0"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Voltage"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/V"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "d15 pos c"
}
]
},
{
- "@id": "http://example.org/IBAL#v12_pos_c",
+ "@id": "http://example.org/IBAL#zs3_t_sp_f",
"@type": [
- "http://data.ashrae.org/bacnet/2020#AnalogOutputObject",
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/bacnet/2020#AnalogInputObject",
+ "http://data.ashrae.org/standard223#QuantifiableProperty"
],
"http://data.ashrae.org/bacnet/2020#description": [
{
- "@value": "AHU1 Cooling Coil Valve Control Signal"
+ "@value": "Zone3 Temperature Setpoint"
}
],
"http://data.ashrae.org/bacnet/2020#object-identifier": [
{
- "@value": "analog-output,2"
+ "@value": "analog-input,6"
}
],
"http://data.ashrae.org/bacnet/2020#object-name": [
{
- "@value": "v12_pos_c"
+ "@value": "zs3_t_sp_f"
}
],
"http://data.ashrae.org/bacnet/2020#object-type": [
{
- "@value": "analog-output"
+ "@value": "analog-input"
}
],
"http://data.ashrae.org/bacnet/2020#objectOf": [
{
- "@id": "http://example.org/IBAL#AHU_2"
+ "@id": "http://example.org/IBAL#VAV_3"
}
],
"http://data.ashrae.org/bacnet/2020#present-value": [
{
"@type": "http://www.w3.org/2001/XMLSchema#float",
- "@value": "0.0"
- }
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Voltage"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
- {
- "@id": "http://qudt.org/vocab/unit/V"
+ "@value": "74.0"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@value": "v12 pos c"
+ "@id": "http://data.ashrae.org/standard223#Aspect-Setpoint"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#Junction_5",
- "@type": [
- "http://data.ashrae.org/standard223#Junction"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#Jnc5-ICP1"
- },
- {
- "@id": "http://example.org/IBAL#Jnc5-ICP2"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://example.org/IBAL#Jnc5-OCP"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Junction 5"
+ "@value": "zs3 t sp f"
}
]
},
{
- "@id": "http://example.org/IBAL#Junction_9",
+ "@id": "http://example.org/IBAL#Junction_26",
"@type": [
"http://data.ashrae.org/standard223#Junction"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Jnc9-ICP"
+ "@id": "http://example.org/IBAL#Jnc26-ICP1"
},
{
- "@id": "http://example.org/IBAL#Jnc9-OCP"
+ "@id": "http://example.org/IBAL#Jnc26-ICP2"
},
{
- "@id": "http://example.org/IBAL#Jnc9-OCP2"
+ "@id": "http://example.org/IBAL#Jnc26-OCP"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Junction 9"
+ "@value": "Junction 26"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_73",
+ "@id": "http://example.org/IBAL#VAV_2_Connection_1",
"@type": [
"http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#connectsAt": [
{
- "@id": "http://example.org/IBAL#Jnc27-ICP"
+ "@id": "http://example.org/IBAL#Damper_2_OCP"
},
{
- "@id": "http://example.org/IBAL#WaterPump_1_OCP"
+ "@id": "http://example.org/IBAL#HC_3_ICP"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 73"
+ "@value": "VAV 2 Connection 1"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_7",
+ "@id": "http://example.org/IBAL#CC_2_Bypass_Connection",
"@type": [
"http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#connectsAt": [
{
- "@id": "http://example.org/IBAL#Jnc3-OCP"
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_1_OCP"
},
{
- "@id": "http://example.org/IBAL#VAV_3_ICP"
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_2_ICP_2"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 7"
+ "@value": "CC 2 Bypass Connection"
}
]
},
{
- "@id": "http://example.org/IBAL#HC-1-InletTemp",
+ "@id": "http://example.org/IBAL#ahu1_t_ra",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://data.ashrae.org/standard223#hasValue": [
{
"@type": "http://www.w3.org/2001/XMLSchema#decimal",
- "@value": "40"
+ "@value": "65"
}
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
@@ -2038,78 +2216,79 @@
"@id": "http://qudt.org/vocab/unit/DEG_F"
}
],
- "http://qudt.org/schema/qudt/value": [
- {
- "@value": "40"
- }
- ],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "HC 1 InletTemp"
+ "@value": "AHU 1 T RA"
}
]
},
{
- "@id": "http://example.org/IBAL#Damper_10_OCP",
+ "@id": "http://example.org/IBAL#HeatingCoil_6",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#HeatingCoil"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://example.org/IBAL#HC_6_E_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_6_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_6_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_6_W_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_6_W_OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@value": "IBAL:VAV4_OCP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Damper 10 OCP"
+ "@value": "Heating coil 6"
}
]
},
{
- "@id": "http://example.org/IBAL#MotorizedDamper_3",
+ "@id": "http://example.org/IBAL#Jnc32-ICP1",
"@type": [
- "http://data.ashrae.org/standard223#Damper"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "http://example.org/IBAL#Damper_3_ICP"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#Damper_3_OCP"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Motorized damper 3"
+ "@value": "Jnc32-ICP1"
}
]
},
{
- "@id": "http://example.org/IBAL#CC_2_Bypass_Connection",
+ "@id": "http://example.org/IBAL#HC_7_E_ICP",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
- ],
- "http://data.ashrae.org/standard223#connectsAt": [
- {
- "@id": "http://example.org/IBAL#ManualTwoWayValve_1_OCP"
- },
- {
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_2_ICP_2"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "CC 2 Bypass Connection"
+ "@value": "HC 7 E ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#ahu2_cc_in_rtd",
+ "@id": "http://example.org/IBAL#ts_in_rtd",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -2125,193 +2304,140 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "ahu2 cc in rtd"
+ "@value": "ts in rtd"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc33-OCP",
+ "@id": "http://example.org/IBAL#vav1_heat_c",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/bacnet/2020#AnalogOutputObject",
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/bacnet/2020#description": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@value": "VAV1 Heater Control Signal"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/bacnet/2020#object-identifier": [
{
- "@value": "Jnc33-OCP"
+ "@value": "analog-output,1"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_3_ICP_1",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/bacnet/2020#object-name": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@value": "vav1_heat_c"
}
],
- "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ "http://data.ashrae.org/bacnet/2020#object-type": [
{
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_3"
+ "@value": "analog-output"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/bacnet/2020#objectOf": [
{
- "@value": "Motorized three way valve 3 ICP 1"
+ "@id": "http://example.org/IBAL#VAV_1"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#Channel_363",
- "@type": [
- "http://data.ashrae.org/standard223#Controller"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/bacnet/2020#present-value": [
{
- "@id": "http://example.org/IBAL#MotorizedDamper_3"
+ "@type": "http://www.w3.org/2001/XMLSchema#float",
+ "@value": "0.0"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://example.org/IBAL#d17_pos_fb"
+ "@id": "http://qudt.org/vocab/quantitykind/Voltage"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 363"
+ "@value": "vav1 heat c"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_12",
+ "@id": "http://example.org/IBAL#Channel_66",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#ElectricMeter"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#HVAC_Space_1_OCP"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#Jnc5-ICP1"
+ "@id": "http://example.org/IBAL#HeatingCoil_6"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://example.org/IBAL#vav4_heat_power"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 12"
+ "@value": "Channel 66"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_87",
+ "@id": "http://example.org/IBAL#Enclosure_4",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#Jnc32-ICP1"
- },
- {
- "@id": "http://example.org/IBAL#ManualTwoWayValve_5_OCP"
- }
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://example.org/IBAL#HVACSpace_4"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 87"
+ "@value": "Enclosure 4"
}
]
},
{
- "@id": "http://example.org/IBAL#VAV_2_OCP",
+ "@id": "http://example.org/IBAL#Jnc33-ICP2",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "VAV 2 OCP"
- }
- ]
- },
- {
- "@id": "http://example.org/IBAL#Channel_77",
- "@type": [
- "http://data.ashrae.org/standard223#TemperatureSensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "http://example.org/IBAL#AHU_1_ICP"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
- {
- "@id": "http://example.org/IBAL#ahu2_in_rtd"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "Channel 77"
- }
- ]
- },
- {
- "@id": "http://example.org/IBAL#Channel_17",
- "@type": [
- "http://data.ashrae.org/standard223#PressureSensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "http://example.org/IBAL#Exhaust_Fan_2_Connection_2"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
{
- "@id": "http://example.org/IBAL#exf2_p_down"
+ "@id": "http://example.org/IBAL#Junction_33"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 17"
+ "@value": "Jnc33-ICP2"
}
]
},
{
- "@id": "http://example.org/IBAL#v13_pos_fb",
+ "@id": "http://example.org/IBAL#vav3_t_in",
"@type": [
"http://data.ashrae.org/bacnet/2020#AnalogInputObject",
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://data.ashrae.org/bacnet/2020#description": [
{
- "@value": "AHU2 Cooling Coil Feedback Signal"
+ "@value": "VAV3 Supply Air Temperature"
}
],
"http://data.ashrae.org/bacnet/2020#object-identifier": [
{
- "@value": "analog-input,2"
+ "@value": "analog-input,3"
}
],
"http://data.ashrae.org/bacnet/2020#object-name": [
{
- "@value": "v13_pos_fb"
+ "@value": "vav3_t_in"
}
],
"http://data.ashrae.org/bacnet/2020#object-type": [
@@ -2321,150 +2447,151 @@
],
"http://data.ashrae.org/bacnet/2020#objectOf": [
{
- "@id": "http://example.org/IBAL#AHU_1"
+ "@id": "http://example.org/IBAL#VAV_3"
}
],
"http://data.ashrae.org/bacnet/2020#present-value": [
{
"@type": "http://www.w3.org/2001/XMLSchema#float",
- "@value": "0.0"
+ "@value": "70.0"
}
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Voltage"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "v13 pos fb"
+ "@value": "vav3 t in"
}
]
},
{
- "@id": "http://example.org/IBAL#VAV4_FnB",
+ "@id": "http://example.org/IBAL#Channel_403",
"@type": [
- "http://data.ashrae.org/standard223#FunctionBlock"
+ "http://data.ashrae.org/standard223#Controller"
],
- "http://data.ashrae.org/standard223#hasInput": [
- {
- "@id": "http://example.org/IBAL#d18_pos_fb"
- },
- {
- "@id": "http://example.org/IBAL#vav4_f"
- },
- {
- "@id": "http://example.org/IBAL#vav4_out_rtd"
- },
- {
- "@id": "http://example.org/IBAL#vav4_t_in"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#zs4_out_rtd"
- },
+ "@id": "http://example.org/IBAL#HeatingCoil_5"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#zs4_t_sp_f"
+ "@id": "http://example.org/IBAL#vav3_heat_c"
}
],
- "http://data.ashrae.org/standard223#hasOutput": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://example.org/IBAL#d18_pos_c"
- },
+ "@value": "Channel 403"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#AHU_2_G_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#vav4_heat_c"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "VAV4 Fn b"
+ "@value": "AHU 2 G OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_89",
+ "@id": "http://example.org/IBAL#Segment_45",
"@type": [
- "http://data.ashrae.org/standard223#TemperatureSensor"
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#VAV_3_Connection_2"
+ "@id": "http://example.org/IBAL#Damper_15_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc15-OCP1"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#vav3_out_rtd"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 89"
+ "@value": "Segment 45"
}
]
},
{
- "@id": "http://example.org/IBAL#HC_4_OCP",
+ "@id": "http://example.org/IBAL#Channel_73",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#TemperatureSensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://example.org/IBAL#HC_4_ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#ahu1_in_rtd"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "HC 4 OCP"
+ "@value": "Channel 73"
}
]
},
{
- "@id": "http://example.org/IBAL#AHU_1_Connection_2",
+ "@id": "http://example.org/IBAL#MotorizedDamper_10",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#Damper"
],
- "http://data.ashrae.org/standard223#connectsAt": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://example.org/IBAL#CC_1_ICP"
+ "@id": "http://example.org/IBAL#Damper_10_ICP"
},
{
- "@id": "http://example.org/IBAL#HC_1_OCP"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://example.org/IBAL#Damper_10_OCP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "AHU 1 Connection 2"
+ "@value": "Motorized damper 10"
}
]
},
{
- "@id": "http://example.org/IBAL#vav4_t_in",
+ "@id": "http://example.org/IBAL#zs3_out_rtd",
"@type": [
"http://data.ashrae.org/bacnet/2020#AnalogInputObject",
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://data.ashrae.org/bacnet/2020#description": [
{
- "@value": "VAV4 Supply Air Temperature"
+ "@value": "Zone3 Temperature"
}
],
"http://data.ashrae.org/bacnet/2020#object-identifier": [
{
- "@value": "analog-input,3"
+ "@value": "analog-input,5"
}
],
"http://data.ashrae.org/bacnet/2020#object-name": [
{
- "@value": "vav4_t_in"
+ "@value": "zs3_out_rtd"
}
],
"http://data.ashrae.org/bacnet/2020#object-type": [
@@ -2474,7 +2601,7 @@
],
"http://data.ashrae.org/bacnet/2020#objectOf": [
{
- "@id": "http://example.org/IBAL#VAV_4"
+ "@id": "http://example.org/IBAL#HVACZone_3"
}
],
"http://data.ashrae.org/bacnet/2020#present-value": [
@@ -2495,80 +2622,101 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "vav4 t in"
+ "@value": "zs3 out rtd"
}
]
},
{
- "@id": "http://example.org/IBAL#Fan_4",
+ "@id": "http://example.org/IBAL#HVACSpace_1",
"@type": [
- "http://data.ashrae.org/standard223#Fan"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://example.org/IBAL#Fan_4_E_ICP"
+ "@id": "http://example.org/IBAL#HVAC_Space_1_ICP"
},
{
- "@id": "http://example.org/IBAL#Fan_4_ICP"
- },
+ "@id": "http://example.org/IBAL#HVAC_Space_1_OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://example.org/IBAL#Fan_4_OCP"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "http://example.org/IBAL#zs1_t_sp_f"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Fan 4"
+ "@value": "HVACSpace 1"
}
]
},
{
- "@id": "http://example.org/IBAL#VFD_4_ICP",
+ "@id": "http://example.org/IBAL#Jnc27-OCP2",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "VFD 4 ICP"
+ "@value": "Jnc27-OCP2"
}
]
},
{
- "@id": "http://example.org/IBAL#Damper_7_ICP",
+ "@id": "http://example.org/IBAL#d5_pos_fb",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/PositionVector"
}
],
- "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://example.org/IBAL#MotorizedDamper_7"
+ "@value": "d5 pos fb"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_6",
+ "@type": [
+ "http://data.ashrae.org/standard223#Damper"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#Damper_6_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_6_OCP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Damper 7 ICP"
+ "@value": "Motorized damper 6"
}
]
},
{
- "@id": "http://example.org/IBAL#Exhaust_Fan_2_Connection_2",
+ "@id": "http://example.org/IBAL#Segment_25",
"@type": [
"http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/standard223#connectsAt": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Damper_9_ICP"
+ "@id": "http://example.org/IBAL#Damper_6_OCP"
},
{
- "@id": "http://example.org/IBAL#Fan_4_OCP"
+ "@id": "http://example.org/IBAL#Jnc9-ICP"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -2578,550 +2726,592 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Exhaust Fan 2 Connection 2"
+ "@value": "Segment 25"
}
]
},
{
- "@id": "http://example.org/IBAL#vav4_out_rtd",
+ "@id": "http://example.org/IBAL#VAV_2_ICP",
"@type": [
- "http://data.ashrae.org/bacnet/2020#AnalogInputObject",
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/bacnet/2020#description": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@value": "VAV4 Discharge Temperature"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/bacnet/2020#object-identifier": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "analog-input,2"
+ "@value": "VAV 2 ICP"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc1-ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/bacnet/2020#object-name": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@value": "vav4_out_rtd"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/bacnet/2020#object-type": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "analog-input"
+ "@value": "Jnc1-ICP"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Chiller_2_Lower_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/bacnet/2020#objectOf": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#VAV_4"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://data.ashrae.org/bacnet/2020#present-value": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@type": "http://www.w3.org/2001/XMLSchema#float",
- "@value": "70.0"
+ "@value": "Chiller 2 Lower OCP"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_10",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://example.org/IBAL#Jnc4-OCP2"
+ },
+ {
+ "@id": "http://example.org/IBAL#VAV_4_ICP"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_F"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "vav4 out rtd"
+ "@value": "Segment 10"
}
]
},
{
- "@id": "http://example.org/IBAL#HVAC_Space_1_OCP",
+ "@id": "http://example.org/IBAL#Jnc34-OCP1",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#Segment_12"
- }
- ],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "HVAC Space1 OCP"
+ "@value": "Jnc34-OCP1"
}
]
},
{
- "@id": "http://example.org/IBAL#v8_pos_fb",
+ "@id": "http://example.org/IBAL#Channel_63",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#ElectricMeter"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Voltage"
+ "@id": "http://example.org/IBAL#HeatingCoil_2"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "http://example.org/IBAL#vav1_heat_power"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "v8 pos fb"
+ "@value": "Channel 63"
}
]
},
{
- "@id": "http://example.org/IBAL#ahu2_cc_rtd",
+ "@id": "http://example.org/IBAL#ahu1_out_rtd",
"@type": [
+ "http://data.ashrae.org/bacnet/2020#AnalogInputObject",
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/bacnet/2020#description": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@value": "AHU1 Supply Air Temperature"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/bacnet/2020#object-identifier": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_F"
+ "@value": "analog-input,2"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/bacnet/2020#object-name": [
{
- "@value": "ahu2 cc rtd"
+ "@value": "ahu1_out_rtd"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#HVACZone_3",
- "@type": [
- "http://data.ashrae.org/standard223#Zone"
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/bacnet/2020#object-type": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@value": "analog-input"
}
],
- "http://data.ashrae.org/standard223#hasDomainSpace": [
+ "http://data.ashrae.org/bacnet/2020#objectOf": [
{
- "@id": "http://example.org/IBAL#HVACSpace_3"
+ "@id": "http://example.org/IBAL#AHU_2"
+ }
+ ],
+ "http://data.ashrae.org/bacnet/2020#present-value": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#float",
+ "@value": "70.0"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "HVACZone 3"
+ "@value": "AHU 1 Out RTD"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc15-OCP1",
+ "@id": "http://example.org/IBAL#Jnc25-OCP1",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc15-OCP1"
+ "@value": "Jnc25-OCP1"
}
]
},
{
- "@id": "http://example.org/IBAL#d10_pos_fb",
+ "@id": "http://example.org/IBAL#HC_1_E_ICP",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositionVector"
+ "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "d10 pos fb"
+ "@value": "HC 1 E ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#Fan_1_OCP",
+ "@id": "http://example.org/IBAL#Damper_19_ICP",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_19"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
{
- "@id": "http://example.org/IBAL#AHU_1_OCP"
+ "@id": "http://example.org/IBAL#MotorizedDamper_19"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Fan 1 OCP"
+ "@value": "Damper 19 ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc7-ICP",
+ "@id": "http://example.org/IBAL#Fan_5_OCP",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "http://example.org/IBAL#AHU_3_OCP"
+ }
+ ],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc7-ICP"
+ "@value": "Fan 5 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_160",
+ "@id": "http://example.org/IBAL#vav4_t_in",
"@type": [
- "http://data.ashrae.org/standard223#TemperatureSensor"
+ "http://data.ashrae.org/bacnet/2020#AnalogInputObject",
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/bacnet/2020#description": [
{
- "@id": "http://example.org/IBAL#Segment_70"
+ "@value": "VAV4 Supply Air Temperature"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/bacnet/2020#object-identifier": [
{
- "@id": "http://example.org/IBAL#pl_in_rtd"
+ "@value": "analog-input,3"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/bacnet/2020#object-name": [
{
- "@value": "Channel 160"
+ "@value": "vav4_t_in"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#ManualTwoWayValve_3",
- "@type": [
- "http://data.ashrae.org/standard223#TwoWayValve"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/bacnet/2020#object-type": [
{
- "@id": "http://example.org/IBAL#ManualTwoWayValve_3_ICP"
- },
+ "@value": "analog-input"
+ }
+ ],
+ "http://data.ashrae.org/bacnet/2020#objectOf": [
{
- "@id": "http://example.org/IBAL#ManualTwoWayValve_3_OCP"
+ "@id": "http://example.org/IBAL#VAV_4"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/bacnet/2020#present-value": [
{
- "@value": "Manual two way valve 3"
+ "@type": "http://www.w3.org/2001/XMLSchema#float",
+ "@value": "70.0"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#HC_2_ICP",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "HC 2 ICP"
+ "@value": "vav4 t in"
}
]
},
{
- "@id": "http://example.org/IBAL#ManualTwoWayValve_5_OCP",
+ "@id": "http://example.org/IBAL#Junction_22",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Junction"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Segment_87"
+ "@id": "http://example.org/IBAL#Jnc22-ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc22-OCP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc22-OCP2"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Manual two way valve 5 OCP"
+ "@value": "Junction 22"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc30-ICP",
+ "@id": "http://example.org/IBAL#Segment_88_Temp",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@value": "Jnc30-ICP"
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#MotorizedDamper_5",
- "@type": [
- "http://data.ashrae.org/standard223#Damper"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "http://example.org/IBAL#Damper_5_ICP"
- },
+ "http://qudt.org/schema/qudt/value": [
{
- "@id": "http://example.org/IBAL#Damper_5_OCP"
+ "@value": "62"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Motorized damper 5"
+ "@value": "Segment_88_Temp"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_301",
+ "@id": "http://example.org/IBAL#PlateHeatExchange_2_Upper_OCP",
"@type": [
- "http://data.ashrae.org/standard223#FlowSensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "http://example.org/IBAL#Segment_2"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#vav1_f"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 301"
+ "@value": "Plate Heat Exchange 2 Upper OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_100",
+ "@id": "http://example.org/IBAL#VAV_3",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/bacnet/2020#BACnetDevice",
+ "http://data.ashrae.org/standard223#TerminalUnit"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/bacnet/2020#hasPort": [
{
- "@id": "http://example.org/IBAL#Jnc37-OCP1"
+ "@id": "http://data.ashrae.org/bacnet/2020#P_47813"
+ }
+ ],
+ "http://data.ashrae.org/standard223#contains": [
+ {
+ "@id": "http://example.org/IBAL#HeatingCoil_5"
},
{
- "@id": "http://example.org/IBAL#Jnc38-ICP"
+ "@id": "http://example.org/IBAL#MotorizedDamper_3"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://example.org/IBAL#VAV_3_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#VAV_3_OCP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 100"
+ "@value": "VAV 3"
}
]
},
{
- "@id": "http://example.org/IBAL#Junction_34",
+ "@id": "http://example.org/IBAL#Channel_329AO",
"@type": [
- "http://data.ashrae.org/standard223#Junction"
+ "http://data.ashrae.org/standard223#Controller"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#Jnc34-ICP"
- },
- {
- "@id": "http://example.org/IBAL#Jnc34-OCP1"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#Jnc34-OCP2"
+ "@id": "http://example.org/IBAL#MotorizedDamper_13"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observers": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://example.org/IBAL#d6_pos_c"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Junction 34"
+ "@value": "Channel 329AO"
}
]
},
{
- "@id": "http://example.org/IBAL#AHU_3_G_OCP",
+ "@id": "http://example.org/IBAL#Jnc16-OCP2",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "AHU 3 G OCP"
+ "@value": "Jnc16-OCP2"
}
]
},
{
- "@id": "http://example.org/IBAL#HVAC_Space_3_ICP",
+ "@id": "http://example.org/IBAL#Chiller_1_Lower_Connection",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#connectsAt": [
+ {
+ "@id": "http://example.org/IBAL#Chiller_1_Lower_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#WaterPump_2_ICP"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Water-ChilledWater"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "HVAC Space 3 ICP"
+ "@value": "Chiller 1 Lower Connection"
}
]
},
{
- "@id": "http://example.org/IBAL#WaterPump_1_ICP",
+ "@id": "http://example.org/IBAL#Channel_110",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#TemperatureSensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://example.org/IBAL#Segment_16"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#zs3_out_rtd"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Water pump 1 ICP"
+ "@value": "Channel 110"
}
]
},
{
- "@id": "http://example.org/IBAL#zs1_rh",
+ "@id": "http://example.org/IBAL#Segment_67",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasValue": [
- {
- "@type": "http://www.w3.org/2001/XMLSchema#decimal",
- "@value": "80"
- }
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "http://example.org/IBAL#Jnc23-OCP"
+ },
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "http://example.org/IBAL#Jnc24-ICP"
}
],
- "http://qudt.org/schema/qudt/value": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@value": "80"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "zs1_rh"
+ "@value": "Segment 67"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_7",
+ "@id": "http://example.org/IBAL#Segment_97",
"@type": [
- "http://data.ashrae.org/standard223#HumiditySensor"
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#AHU_1_ICP"
+ "@id": "http://example.org/IBAL#Jnc36-ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#WaterPump_4_OCP"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#ahu2_rh_up"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 7"
+ "@value": "Segment 97"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc21-ICP2",
+ "@id": "http://example.org/IBAL#Channel_453",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Controller"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://example.org/IBAL#VFD_3"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#exf1_vfd"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc21-ICP2"
+ "@value": "Channel 453"
}
]
},
{
- "@id": "http://example.org/IBAL#Fan_2",
+ "@id": "http://example.org/IBAL#Channel_80",
"@type": [
- "http://data.ashrae.org/standard223#Fan"
+ "http://data.ashrae.org/standard223#TemperatureSensor"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "http://example.org/IBAL#Fan_2_ICP"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#Fan_2_OCP"
- },
+ "@id": "http://example.org/IBAL#Segment_1"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#Fan_2_S_ICP"
+ "@id": "http://example.org/IBAL#ahu2_out_rtd"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Fan 2"
+ "@value": "Channel 80"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_38",
+ "@id": "http://example.org/IBAL#Junction_15",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#Junction"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Damper_13_ICP"
+ "@id": "http://example.org/IBAL#Jnc15-ICP"
},
{
- "@id": "http://example.org/IBAL#Jnc12-OCP1"
+ "@id": "http://example.org/IBAL#Jnc15-OCP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc15-OCP2"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -3131,189 +3321,179 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 38"
+ "@value": "Junction 15"
}
]
},
{
- "@id": "http://example.org/IBAL#ch1_f_e",
+ "@id": "http://example.org/IBAL#Channel_336",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Controller"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://example.org/IBAL#MotorizedDamper_1"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/GAL_US-PER-MIN"
+ "@id": "http://example.org/IBAL#d15_pos_fb"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "ch1 f e"
+ "@value": "Channel 336"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc9-OCP2",
+ "@id": "http://example.org/IBAL#Jnc35-ICP2",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Segment_27"
+ "@id": "http://example.org/IBAL#Segment_93"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc9-OCP2"
+ "@value": "Jnc35-ICP2"
}
]
},
{
- "@id": "http://example.org/IBAL#HC_6_ICP",
+ "@id": "http://example.org/IBAL#Segment_85",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc31-OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc32-ICP2"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "HC 6 ICP"
+ "@value": "Segment 85"
}
]
},
{
- "@id": "http://example.org/IBAL#WaterTempSensor_13",
+ "@id": "http://example.org/IBAL#HC_1_ICP",
"@type": [
- "http://data.ashrae.org/standard223#TemperatureSensor"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#Segment_97"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://example.org/IBAL#Segment_97_Temp"
+ "@id": "http://example.org/IBAL#AHU_1_ICP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Water Temp Sensor 13"
+ "@value": "HC 1 ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#MotorizedDamper_19",
+ "@id": "http://example.org/IBAL#WaterPump_3_ICP",
"@type": [
- "http://data.ashrae.org/standard223#Damper"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "http://example.org/IBAL#Damper_19_ICP"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#Damper_19_OCP"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Motorized damper 19"
+ "@value": "Water pump 3 ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_59",
+ "@id": "http://example.org/IBAL#Segment_44",
"@type": [
"http://data.ashrae.org/standard223#Connection"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Jnc21-ICP2"
- },
- {
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_1_OCP"
+ "@id": "http://example.org/IBAL#Jnc15-ICP"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 59"
+ "@value": "Segment 44"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_495",
+ "@id": "http://example.org/IBAL#Jnc37-OCP1",
"@type": [
- "http://data.ashrae.org/standard223#Controller"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "http://example.org/IBAL#MotorizedDamper_8"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#d10_pos_fb"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 495"
+ "@value": "Jnc37-OCP1"
}
]
},
{
- "@id": "http://example.org/IBAL#AHU_2_Connection_2",
+ "@id": "http://example.org/IBAL#PlateHeatExchanger_2",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#HeatExchanger"
],
- "http://data.ashrae.org/standard223#connectsAt": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://example.org/IBAL#CC_2_ICP"
+ "@id": "http://example.org/IBAL#PlateHeatExchange_2_Lower_ICP"
},
{
- "@id": "http://example.org/IBAL#HC_4_OCP"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "http://example.org/IBAL#PlateHeatExchange_2_Lower_OCP"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://example.org/IBAL#PlateHeatExchange_2_Upper_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#PlateHeatExchange_2_Upper_OCP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "AHU 2 Connection 2"
+ "@value": "Plate heat exchanger 1"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_27",
+ "@id": "http://example.org/IBAL#Damper_17_ICP",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#Fan_3_ICP"
- },
- {
- "@id": "http://example.org/IBAL#Jnc9-OCP2"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -3322,106 +3502,80 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 27"
+ "@value": "Damper 17 ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#zs3_out_rtd",
+ "@id": "http://example.org/IBAL#Fan_1",
"@type": [
- "http://data.ashrae.org/bacnet/2020#AnalogInputObject",
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/bacnet/2020#description": [
- {
- "@value": "Zone3 Temperature"
- }
- ],
- "http://data.ashrae.org/bacnet/2020#object-identifier": [
- {
- "@value": "analog-input,5"
- }
- ],
- "http://data.ashrae.org/bacnet/2020#object-name": [
- {
- "@value": "zs3_out_rtd"
- }
- ],
- "http://data.ashrae.org/bacnet/2020#object-type": [
- {
- "@value": "analog-input"
- }
- ],
- "http://data.ashrae.org/bacnet/2020#objectOf": [
- {
- "@id": "http://example.org/IBAL#HVACZone_3"
- }
+ "http://data.ashrae.org/standard223#Fan"
],
- "http://data.ashrae.org/bacnet/2020#present-value": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@type": "http://www.w3.org/2001/XMLSchema#float",
- "@value": "70.0"
- }
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "@id": "http://example.org/IBAL#Fan_1_ICP"
+ },
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "http://example.org/IBAL#Fan_1_OCP"
+ },
{
- "@id": "http://qudt.org/vocab/unit/DEG_F"
+ "@id": "http://example.org/IBAL#Fan_1_S_ICP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "zs3 out rtd"
+ "@value": "Fan 1"
}
]
},
{
- "@id": "http://example.org/IBAL#zs3_heat_rtd",
+ "@id": "http://example.org/IBAL#Channel_404",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Controller"
],
- "http://data.ashrae.org/standard223#hasValue": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@type": "http://www.w3.org/2001/XMLSchema#decimal",
- "@value": "66"
+ "@id": "http://example.org/IBAL#HeatingCoil_6"
}
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://example.org/IBAL#vav4_heat_c"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_F"
+ "@value": "Channel 404"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#AHU_1_G_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/value": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@value": "66"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "zs3 heat rtd"
+ "@value": "AHU 1 G OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_97",
+ "@id": "http://example.org/IBAL#Segment_84",
"@type": [
"http://data.ashrae.org/standard223#Connection"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Jnc36-ICP"
+ "@id": "http://example.org/IBAL#Jnc30-OCP"
},
{
- "@id": "http://example.org/IBAL#WaterPump_4_OCP"
+ "@id": "http://example.org/IBAL#Jnc31-ICP1"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -3431,77 +3585,73 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 97"
+ "@value": "Segment 84"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_73",
+ "@id": "http://example.org/IBAL#HeatExchange_Connection",
"@type": [
- "http://data.ashrae.org/standard223#TemperatureSensor"
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#HC_4_ICP"
+ "@id": "http://example.org/IBAL#PlateHeatExchange_2_Lower_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#WaterPump_1_ICP"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#ahu1_in_rtd"
+ "@id": "http://data.ashrae.org/standard223#Water-ChilledWater"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 73"
+ "@value": "Heat Exchange Connection"
}
]
},
{
- "@id": "http://example.org/IBAL#AHU_1",
+ "@id": "http://example.org/IBAL#Junction_7",
"@type": [
- "http://data.ashrae.org/standard223#AirHandlingUnit"
+ "http://data.ashrae.org/standard223#Junction"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "http://example.org/IBAL#CoolingCoil_1"
- },
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Fan_1"
+ "@id": "http://example.org/IBAL#Jnc7-ICP"
},
{
- "@id": "http://example.org/IBAL#HeatingCoil_1"
+ "@id": "http://example.org/IBAL#Jnc7-OCP1"
},
{
- "@id": "http://example.org/IBAL#VFD_1"
+ "@id": "http://example.org/IBAL#Jnc7-OCP2"
}
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "http://example.org/IBAL#AHU_1_G_ICP"
- },
- {
- "@id": "http://example.org/IBAL#AHU_1_G_OCP"
- },
- {
- "@id": "http://example.org/IBAL#AHU_1_ICP"
- },
- {
- "@id": "http://example.org/IBAL#AHU_1_OCP"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#AHU_1_S_ICP"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "AHU 1"
+ "@value": "Junction 7"
}
]
},
{
- "@id": "http://example.org/IBAL#Fan_3_ICP",
+ "@id": "http://example.org/IBAL#Segment_8",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc3-ICP2"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc4-OCP1"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -3510,154 +3660,249 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Fan 3 ICP"
+ "@value": "Segment 8"
}
]
},
{
- "@id": "http://example.org/IBAL#Junction_29",
+ "@id": "http://example.org/IBAL#Junction_4",
"@type": [
"http://data.ashrae.org/standard223#Junction"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Jnc29-ICP"
+ "@id": "http://example.org/IBAL#Jnc4-ICP"
},
{
- "@id": "http://example.org/IBAL#Jnc29-OCP"
+ "@id": "http://example.org/IBAL#Jnc4-OCP1"
},
{
- "@id": "http://example.org/IBAL#Jnc29-OCP2"
+ "@id": "http://example.org/IBAL#Jnc4-OCP2"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Junction 29"
+ "@value": "Junction 4"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc16-OCP2",
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_5_OCP",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Segment_87"
+ }
+ ],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc16-OCP2"
+ "@value": "Manual two way valve 5 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#VAV1_FnB",
+ "@id": "http://example.org/IBAL#AHU_1_Connection_3",
"@type": [
- "http://data.ashrae.org/standard223#FunctionBlock"
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/standard223#hasInput": [
+ "http://data.ashrae.org/standard223#connectsAt": [
{
- "@id": "http://example.org/IBAL#d15_pos_fb"
+ "@id": "http://example.org/IBAL#CC_1_OCP"
},
{
- "@id": "http://example.org/IBAL#vav1_f"
- },
+ "@id": "http://example.org/IBAL#Fan_1_ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#vav1_out_rtd"
- },
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://example.org/IBAL#vav1_t_in"
+ "@value": "AHU 1 Connection 3"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#AHU_3_Connection_2",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "AHU 3 Connection 2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_5",
+ "@type": [
+ "http://data.ashrae.org/standard223#Fan"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#Fan_5_E_ICP"
},
{
- "@id": "http://example.org/IBAL#zs1_out_rtd"
+ "@id": "http://example.org/IBAL#Fan_5_ICP"
},
{
- "@id": "http://example.org/IBAL#zs1_t_sp_f"
+ "@id": "http://example.org/IBAL#Fan_5_OCP"
}
],
- "http://data.ashrae.org/standard223#hasOutput": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://example.org/IBAL#d15_pos_c"
+ "@value": "Fan 5"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_28",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Damper_8_OCP"
},
{
- "@id": "http://example.org/IBAL#vav1_heat_c"
+ "@id": "http://example.org/IBAL#Jnc10-ICP1"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "VAV1 Fn b"
+ "@value": "Segment 28"
}
]
},
{
- "@id": "http://example.org/IBAL#exf2_power",
+ "@id": "http://example.org/IBAL#CC_1_Water_OCP",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://qudt.org/vocab/unit/W"
+ "@id": "http://example.org/IBAL#AHU_1_G_OCP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "exf2 power"
+ "@value": " CC 1 Water OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Damper_5_ICP",
+ "@id": "http://example.org/IBAL#Channel_411",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Controller"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_2"
}
],
- "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#MotorizedDamper_5"
+ "@id": "http://example.org/IBAL#v13_pos_c"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Damper 5 ICP"
+ "@value": "Channel 411"
}
]
},
{
- "@id": "http://example.org/IBAL#VAV_1_ICP",
+ "@id": "http://example.org/IBAL#oau_cc_rtd",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasValue": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "45"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "VAV 1 ICP"
+ "@value": "oau cc rtd"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc35-OCP",
+ "@id": "http://example.org/IBAL#Channel_105",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#TemperatureSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#HVAC_Space_1_ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#zs1_heat_rtd"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Channel 105"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Junction_31",
+ "@type": [
+ "http://data.ashrae.org/standard223#Junction"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc31-ICP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc31-ICP2"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc31-OCP"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -3666,29 +3911,29 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc35-OCP"
+ "@value": "Junction 31"
}
]
},
{
- "@id": "http://example.org/IBAL#vav1_out_rtd",
+ "@id": "http://example.org/IBAL#d18_pos_fb",
"@type": [
"http://data.ashrae.org/bacnet/2020#AnalogInputObject",
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://data.ashrae.org/bacnet/2020#description": [
{
- "@value": "VAV1 Discharge Temperature"
+ "@value": "VAV4 Damper Feedback Signal"
}
],
"http://data.ashrae.org/bacnet/2020#object-identifier": [
{
- "@value": "analog-input,2"
+ "@value": "analog-input,1"
}
],
"http://data.ashrae.org/bacnet/2020#object-name": [
{
- "@value": "vav1_out_rtd"
+ "@value": "d18_pos_fb"
}
],
"http://data.ashrae.org/bacnet/2020#object-type": [
@@ -3698,168 +3943,166 @@
],
"http://data.ashrae.org/bacnet/2020#objectOf": [
{
- "@id": "http://example.org/IBAL#VAV_1"
+ "@id": "http://example.org/IBAL#VAV_4"
}
],
"http://data.ashrae.org/bacnet/2020#present-value": [
{
"@type": "http://www.w3.org/2001/XMLSchema#float",
- "@value": "70.0"
+ "@value": "0.0"
}
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Voltage"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_F"
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "vav1 out rtd"
+ "@value": "d18 pos fb"
}
]
},
{
- "@id": "http://example.org/IBAL#ManualTwoWayValve_2_OCP",
+ "@id": "http://example.org/IBAL#Jnc30-OCP",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Segment_84"
+ }
+ ],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Manual two way valve 2 OCP"
+ "@value": "Jnc30-OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#zs2_out_rtd",
+ "@id": "http://example.org/IBAL#d18_pos_c",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/bacnet/2020#AnalogOutputObject",
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://data.ashrae.org/bacnet/2020#description": [
{
- "@value": "Zone2 Temperature"
+ "@value": "VAV4 Damper Control Signal"
}
],
"http://data.ashrae.org/bacnet/2020#object-identifier": [
{
- "@value": "analog-input,5"
+ "@value": "analog-output,2"
}
],
"http://data.ashrae.org/bacnet/2020#object-name": [
{
- "@value": "Zone2 Temperature"
+ "@value": "d18_pos_c"
}
],
"http://data.ashrae.org/bacnet/2020#object-type": [
{
- "@value": "analog-input"
+ "@value": "analog-output"
}
],
"http://data.ashrae.org/bacnet/2020#objectOf": [
{
- "@id": "http://example.org/IBAL#VAV_2"
+ "@id": "http://example.org/IBAL#VAV_4"
}
],
"http://data.ashrae.org/bacnet/2020#present-value": [
{
"@type": "http://www.w3.org/2001/XMLSchema#float",
- "@value": "70.0"
+ "@value": "0.0"
}
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Voltage"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_F"
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "zs2 out rtd"
+ "@value": "d18 pos c"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_99",
+ "@id": "http://example.org/IBAL#VFD_2_ICP",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#Jnc36-OCP1"
- },
- {
- "@id": "http://example.org/IBAL#Jnc37-ICP"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 99"
+ "@value": "VFD 2 ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#HC_2_OCP",
+ "@id": "http://example.org/IBAL#CC_1_Water_ICP",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://example.org/IBAL#VAV_1_OCP"
+ "@id": "http://example.org/IBAL#AHU_1_G_ICP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "HC 2 OCP"
+ "@value": "CC 1 Water ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#vav2_t_in",
+ "@id": "http://example.org/IBAL#d16_pos_c",
"@type": [
- "http://data.ashrae.org/bacnet/2020#AnalogInputObject",
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/bacnet/2020#AnalogOutputObject",
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://data.ashrae.org/bacnet/2020#description": [
{
- "@value": "VAV2 Supply Air Temperature"
+ "@value": "VAV2 Damper Control Signal"
}
],
"http://data.ashrae.org/bacnet/2020#object-identifier": [
{
- "@value": "analog-input,3"
+ "@value": "analog-output,2"
}
],
"http://data.ashrae.org/bacnet/2020#object-name": [
{
- "@value": "vav2_t_in"
+ "@value": "d16_pos_c"
}
],
"http://data.ashrae.org/bacnet/2020#object-type": [
{
- "@value": "analog-input"
+ "@value": "analog-output"
}
],
"http://data.ashrae.org/bacnet/2020#objectOf": [
@@ -3870,226 +4113,214 @@
"http://data.ashrae.org/bacnet/2020#present-value": [
{
"@type": "http://www.w3.org/2001/XMLSchema#float",
- "@value": "70.0"
+ "@value": "0.0"
}
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_F"
+ "@id": "http://qudt.org/vocab/unit/A"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "vav2 t in"
+ "@value": "d16 pos c"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_37",
+ "@id": "http://example.org/IBAL#Fan_2",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#Fan"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://example.org/IBAL#Damper_12_OCP"
+ "@id": "http://example.org/IBAL#Fan_2_ICP"
},
{
- "@id": "http://example.org/IBAL#Jnc13-ICP2"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "http://example.org/IBAL#Fan_2_OCP"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://example.org/IBAL#Fan_2_S_ICP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 37"
+ "@value": "Fan 2"
}
]
},
{
- "@id": "http://example.org/IBAL#Damper_19_OCP",
+ "@id": "http://example.org/IBAL#Junction_13",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Junction"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://example.org/IBAL#Jnc13-ICP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc13-ICP2"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc13-OCP"
}
],
- "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#MotorizedDamper_19"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Damper 19 OCP"
+ "@value": "Junction 13"
}
]
},
{
- "@id": "http://example.org/IBAL#Damper_9_ICP",
+ "@id": "http://example.org/IBAL#MotorizedDamper_5",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Damper"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ "@id": "http://example.org/IBAL#Damper_5_ICP"
+ },
{
- "@id": "http://example.org/IBAL#MotorizedDamper_9"
+ "@id": "http://example.org/IBAL#Damper_5_OCP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Damper 9 ICP"
+ "@value": "Motorized damper 5"
}
]
},
{
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_3_OCP",
+ "@id": "http://example.org/IBAL#Segment_23",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://example.org/IBAL#Damper_14_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc8-OCP1"
}
],
- "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_3"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Motorized three way valve 3 OCP"
+ "@value": "Segment 23"
}
]
},
{
- "@id": "http://example.org/IBAL#VFD_5",
+ "@id": "http://example.org/IBAL#AHU1_FnB",
"@type": [
- "http://data.ashrae.org/standard223#VariableFrequencyDrive"
+ "http://data.ashrae.org/standard223#FunctionBlock"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/standard223#hasInput": [
{
- "@id": "http://example.org/IBAL#VFD_5_ICP"
+ "@id": "http://example.org/IBAL#ahu2_out_rtd"
},
{
- "@id": "http://example.org/IBAL#VFD_5_OCP"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "http://example.org/IBAL#ahu2_p_down"
+ },
{
- "@value": "VFD 5"
- }
- ]
- },
- {
- "@id": "http://example.org/IBAL#exf2_t_in",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "@id": "http://example.org/IBAL#d15_pos_c"
+ },
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://example.org/IBAL#d16_pos_c"
+ },
+ {
+ "@id": "http://example.org/IBAL#v13_pos_fb"
+ },
+ {
+ "@id": "http://example.org/IBAL#vav1_heat_c"
+ },
+ {
+ "@id": "http://example.org/IBAL#vav2_heat_c"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasOutput": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_F"
+ "@id": "http://example.org/IBAL#ahu2_vfd"
+ },
+ {
+ "@id": "http://example.org/IBAL#v13_pos_c"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "exf2 t in"
+ "@value": "AHU1 Fn b"
}
]
},
{
- "@id": "http://example.org/IBAL#Damper_12_OCP",
+ "@id": "http://example.org/IBAL#vav1_out_rtd",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/bacnet/2020#AnalogInputObject",
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/bacnet/2020#description": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@value": "VAV1 Discharge Temperature"
}
],
- "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ "http://data.ashrae.org/bacnet/2020#object-identifier": [
{
- "@id": "http://example.org/IBAL#MotorizedDamper_12"
+ "@value": "analog-input,2"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/bacnet/2020#object-name": [
{
- "@value": "Damper 12 OCP"
+ "@value": "vav1_out_rtd"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#Jnc25-ICP",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/bacnet/2020#object-type": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@value": "analog-input"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/bacnet/2020#objectOf": [
{
- "@value": "Jnc25-ICP"
+ "@id": "http://example.org/IBAL#VAV_1"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#MotorizedDamper_2",
- "@type": [
- "http://data.ashrae.org/standard223#Damper"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "http://example.org/IBAL#Damper_2_ICP"
- },
+ "http://data.ashrae.org/bacnet/2020#present-value": [
{
- "@id": "http://example.org/IBAL#Damper_2_OCP"
+ "@type": "http://www.w3.org/2001/XMLSchema#float",
+ "@value": "70.0"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@value": "Motorized damper 2"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#HC_7_OCP",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "HC 7OCP"
+ "@value": "vav1 out rtd"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc13-ICP1",
+ "@id": "http://example.org/IBAL#HC_3_ICP",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -4100,44 +4331,57 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc13-ICP1"
+ "@value": "HC 3 ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc24-OCP2",
+ "@id": "http://example.org/IBAL#Segment_2",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc1-OCP2"
+ },
+ {
+ "@id": "http://example.org/IBAL#VAV_1_ICP"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc24-OCP2"
+ "@value": "Segment 2"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc18-OCP",
+ "@id": "http://example.org/IBAL#Channel_496",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Controller"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://example.org/IBAL#MotorizedDamper_6"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#d11_pos_fb"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc18-OCP"
+ "@value": "Channel 496"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc5-ICP1",
+ "@id": "http://example.org/IBAL#Jnc12-ICP",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -4148,786 +4392,219 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc5-ICP1"
+ "@value": "Jnc12-ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#HC_4_W_OCP",
+ "@id": "http://example.org/IBAL#Jnc31-ICP1",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "HC 4 W OCP"
+ "@value": "Jnc31-ICP1"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc15-OCP2",
+ "@id": "http://example.org/IBAL#Channel_83",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#TemperatureSensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://example.org/IBAL#AHU_3_ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#oau_in_rtd"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc15-OCP2"
+ "@value": "Channel 83"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc21-OCP",
+ "@id": "http://example.org/IBAL#pl_f",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/GAL_US-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc21-OCP"
+ "@value": "pl f"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_106",
- "@type": [
- "http://data.ashrae.org/standard223#Connection"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#AHU_2_G_OCP"
- },
- {
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_2_ICP_1"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "Segment 106"
- }
- ]
- },
- {
- "@id": "http://example.org/IBAL#HeatingCoil_1",
- "@type": [
- "http://data.ashrae.org/standard223#HeatingCoil"
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "http://example.org/IBAL#HC_1_E_ICP"
- },
- {
- "@id": "http://example.org/IBAL#HC_1_ICP"
- },
- {
- "@id": "http://example.org/IBAL#HC_1_OCP"
- },
- {
- "@id": "http://example.org/IBAL#HC_1_W_ICP"
- },
- {
- "@id": "http://example.org/IBAL#HC_1_W_OCP"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "Heating coil 1"
- }
- ]
- },
- {
- "@id": "http://example.org/IBAL#HC_3_W_OCP",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "HC 3 W OCP"
- }
- ]
- },
- {
- "@id": "http://example.org/IBAL#d15_pos_c",
- "@type": [
- "http://data.ashrae.org/bacnet/2020#AnalogOutputObject",
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/bacnet/2020#description": [
- {
- "@value": "VAV1 Damper Control Signal"
- }
- ],
- "http://data.ashrae.org/bacnet/2020#object-identifier": [
- {
- "@value": "analog-output,2"
- }
- ],
- "http://data.ashrae.org/bacnet/2020#object-name": [
- {
- "@value": "d15_pos_c"
- }
- ],
- "http://data.ashrae.org/bacnet/2020#object-type": [
- {
- "@value": "analog-output"
- }
- ],
- "http://data.ashrae.org/bacnet/2020#objectOf": [
- {
- "@id": "http://example.org/IBAL#VAV_1"
- }
- ],
- "http://data.ashrae.org/bacnet/2020#present-value": [
- {
- "@type": "http://www.w3.org/2001/XMLSchema#float",
- "@value": "0.0"
- }
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Voltage"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
- {
- "@id": "http://qudt.org/vocab/unit/V"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "d15 pos c"
- }
- ]
- },
- {
- "@id": "http://example.org/IBAL#Segment_60",
- "@type": [
- "http://data.ashrae.org/standard223#Connection"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#Jnc20-ICP"
- },
- {
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_2_OCP"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "Segment 60"
- }
- ]
- },
- {
- "@id": "http://example.org/IBAL#Segment_69",
- "@type": [
- "http://data.ashrae.org/standard223#Connection"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#Jnc25-ICP"
- },
- {
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_4_OCP"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "Segment 69"
- }
- ]
- },
- {
- "@id": "http://example.org/IBAL#HC_2_W_OCP",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "HC 2 W OCP"
- }
- ]
- },
- {
- "@id": "http://example.org/IBAL#ahu1_on",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Voltage"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
- {
- "@id": "http://qudt.org/vocab/unit/V"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "ahu1 on"
- }
- ]
- },
- {
- "@id": "http://example.org/IBAL#Flow_7",
- "@type": [
- "http://data.ashrae.org/standard223#FlowSensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "http://example.org/IBAL#VAV_3_Connection_2"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
- {
- "@id": "http://example.org/IBAL#HC-5-OutletFlow"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "Flow 7"
- }
- ]
- },
- {
- "@id": "http://example.org/IBAL#AirFlow",
- "@type": [
- "http://data.ashrae.org/standard223#System"
- ],
- "http://data.ashrae.org/standard223#hasMember": [
- {
- "@id": "http://example.org/IBAL#AHU_1"
- },
- {
- "@id": "http://example.org/IBAL#AHU_2"
- },
- {
- "@id": "http://example.org/IBAL#Fan_3"
- },
- {
- "@id": "http://example.org/IBAL#Fan_4"
- },
- {
- "@id": "http://example.org/IBAL#MotorizedDamper_10"
- },
- {
- "@id": "http://example.org/IBAL#MotorizedDamper_11"
- },
- {
- "@id": "http://example.org/IBAL#MotorizedDamper_12"
- },
- {
- "@id": "http://example.org/IBAL#MotorizedDamper_13"
- },
- {
- "@id": "http://example.org/IBAL#MotorizedDamper_14"
- },
- {
- "@id": "http://example.org/IBAL#MotorizedDamper_15"
- },
- {
- "@id": "http://example.org/IBAL#MotorizedDamper_16"
- },
- {
- "@id": "http://example.org/IBAL#MotorizedDamper_17"
- },
- {
- "@id": "http://example.org/IBAL#MotorizedDamper_18"
- },
- {
- "@id": "http://example.org/IBAL#MotorizedDamper_19"
- },
- {
- "@id": "http://example.org/IBAL#MotorizedDamper_5"
- },
- {
- "@id": "http://example.org/IBAL#MotorizedDamper_6"
- },
- {
- "@id": "http://example.org/IBAL#MotorizedDamper_7"
- },
- {
- "@id": "http://example.org/IBAL#MotorizedDamper_8"
- },
- {
- "@id": "http://example.org/IBAL#MotorizedDamper_9"
- },
- {
- "@id": "http://example.org/IBAL#VAV_1"
- },
- {
- "@id": "http://example.org/IBAL#VAV_2"
- },
- {
- "@id": "http://example.org/IBAL#VAV_3"
- },
- {
- "@id": "http://example.org/IBAL#VAV_4"
- },
- {
- "@id": "http://example.org/IBAL#VFD_3"
- },
- {
- "@id": "http://example.org/IBAL#VFD_4"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "AirFlow"
- }
- ]
- },
- {
- "@id": "http://example.org/IBAL#Channel_310",
- "@type": [
- "http://data.ashrae.org/standard223#Controller"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "http://example.org/IBAL#MotorizedDamper_14"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
- {
- "@id": "http://example.org/IBAL#d5_pos_fb"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "Channel 310"
- }
- ]
- },
- {
- "@id": "http://example.org/IBAL#ahu2_rh_down",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
- {
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "ahu2 rh down"
- }
- ]
- },
- {
- "@id": "http://example.org/IBAL#PlateHeatExchange_1_Connection",
- "@type": [
- "http://data.ashrae.org/standard223#Connection"
- ],
- "http://data.ashrae.org/standard223#connectsAt": [
- {
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_3_ICP_1"
- },
- {
- "@id": "http://example.org/IBAL#PlateHeatExchange_1_Lower_OCP"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Water-ChilledWater"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "Plate Heat Exchange 1 Connection"
- }
- ]
- },
- {
- "@id": "http://example.org/IBAL#VAV_3_OCP",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "VAV 3 OCP"
- }
- ]
- },
- {
- "@id": "http://example.org/IBAL#Channel_86",
- "@type": [
- "http://data.ashrae.org/standard223#TemperatureSensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "http://example.org/IBAL#Segment_44"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
- {
- "@id": "http://example.org/IBAL#oau_out_rtd"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "Channel 86"
- }
- ]
- },
- {
- "@id": "http://example.org/IBAL#HC_4_E_ICP",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "HC 4 E ICP"
- }
- ]
- },
- {
- "@id": "http://example.org/IBAL#Jnc25-OCP2",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#Segment_71"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "Jnc25-OCP2"
- }
- ]
- },
- {
- "@id": "http://example.org/IBAL#Segment_95",
- "@type": [
- "http://data.ashrae.org/standard223#Connection"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#Jnc24-OCP2"
- },
- {
- "@id": "http://example.org/IBAL#Jnc35-ICP1"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "Segment 95"
- }
- ]
- },
- {
- "@id": "http://example.org/IBAL#Channel_384",
+ "@id": "http://example.org/IBAL#zs2_t_sp_f",
"@type": [
- "http://data.ashrae.org/standard223#Controller"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_2"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
- {
- "@id": "http://example.org/IBAL#v13_pos_fb"
- }
+ "http://data.ashrae.org/bacnet/2020#AnalogInputObject",
+ "http://data.ashrae.org/standard223#QuantifiableProperty"
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/bacnet/2020#description": [
{
- "@value": "Channel 384"
+ "@value": "Zone2 Temperature Setpoint"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#Flow_6",
- "@type": [
- "http://data.ashrae.org/standard223#FlowSensor"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/bacnet/2020#object-identifier": [
{
- "@id": "http://example.org/IBAL#VAV_2_Connection_2"
+ "@value": "analog-input,6"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/bacnet/2020#object-name": [
{
- "@id": "http://example.org/IBAL#HC-3-OutletFlow"
+ "@value": "zs2_t_sp_f"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/bacnet/2020#object-type": [
{
- "@value": "Flow 6"
+ "@value": "analog-input"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#Jnc35-ICP2",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/bacnet/2020#objectOf": [
{
- "@id": "http://example.org/IBAL#Segment_93"
+ "@id": "http://example.org/IBAL#VAV_2"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/bacnet/2020#present-value": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@type": "http://www.w3.org/2001/XMLSchema#float",
+ "@value": "74.0"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@value": "Jnc35-ICP2"
+ "@id": "http://data.ashrae.org/standard223#Aspect-Setpoint"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_2_OCP",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_2"
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Motorized three way valve 2 OCP"
+ "@value": "zs2 t sp f"
}
]
},
{
- "@id": "http://example.org/IBAL#Fan_3_VFD_3",
+ "@id": "http://example.org/IBAL#Segment_102",
"@type": [
"http://data.ashrae.org/standard223#Connection"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Fan_3_E_ICP"
+ "@id": "http://example.org/IBAL#Jnc19-ICP"
},
{
- "@id": "http://example.org/IBAL#VFD_3_OCP"
+ "@id": "http://example.org/IBAL#Jnc37-OCP2"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Fan 3 VFD 3"
+ "@value": "Segment 102"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_9",
+ "@id": "http://example.org/IBAL#Channel_123",
"@type": [
- "http://data.ashrae.org/standard223#PressureSensor"
+ "http://data.ashrae.org/standard223#TemperatureSensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#Segment_1"
+ "@id": "http://example.org/IBAL#Chiller_2_Lower_Connection"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#ahu2_p_down"
+ "@id": "http://example.org/IBAL#ch2_e_out_rtd"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 9"
+ "@value": "Channel 123"
}
]
},
{
- "@id": "http://example.org/IBAL#HeatExchange_Connection",
+ "@id": "http://example.org/IBAL#Segment_3",
"@type": [
"http://data.ashrae.org/standard223#Connection"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#PlateHeatExchange_2_Lower_OCP"
+ "@id": "http://example.org/IBAL#Jnc1-OCP1"
},
{
- "@id": "http://example.org/IBAL#WaterPump_1_ICP"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Water-ChilledWater"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "Heat Exchange Connection"
- }
- ]
- },
- {
- "@id": "http://example.org/IBAL#Jnc37-OCP1",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "Jnc37-OCP1"
- }
- ]
- },
- {
- "@id": "http://example.org/IBAL#Jnc11-ICP2",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "Jnc11-ICP2"
+ "@id": "http://example.org/IBAL#Jnc2-ICP"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#Damper_13_ICP",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#isConnectionPointOf": [
- {
- "@id": "http://example.org/IBAL#MotorizedDamper_13"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "Damper 13 ICP"
- }
- ]
- },
- {
- "@id": "http://example.org/IBAL#MotorizedDamper_11",
- "@type": [
- "http://data.ashrae.org/standard223#Damper"
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "http://example.org/IBAL#Damper_11_ICP"
- },
- {
- "@id": "http://example.org/IBAL#Damper_11_OCP"
- }
- ],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Motorized damper 11"
+ "@value": "Segment 3"
}
]
},
{
- "@id": "http://example.org/IBAL#ManualTwoWayValve_2_ICP",
+ "@id": "http://example.org/IBAL#HC_2_E_ICP",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Manual two way valve 2 ICP"
+ "@value": "HC 2 E ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#AHU_3_OCP",
+ "@id": "http://example.org/IBAL#Damper_6_OCP",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Segment_44"
+ "@id": "http://example.org/IBAL#Fan_3_ICP"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -4935,43 +4612,21 @@
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "AHU 3 OCP"
- }
- ]
- },
- {
- "@id": "http://example.org/IBAL#HC_7_W_OCP",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://example.org/IBAL#MotorizedDamper_6"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "HC 7 W OCP"
+ "@value": "Damper 6 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Junction_27",
+ "@id": "http://example.org/IBAL#Jnc35-OCP",
"@type": [
- "http://data.ashrae.org/standard223#Junction"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#Jnc27-ICP"
- },
- {
- "@id": "http://example.org/IBAL#Jnc27-OCP1"
- },
- {
- "@id": "http://example.org/IBAL#Jnc27-OCP2"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -4980,369 +4635,334 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Junction 27"
- }
- ]
- },
- {
- "@id": "http://example.org/IBAL#MotorizedDamper_17",
- "@type": [
- "http://data.ashrae.org/standard223#Damper"
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "http://example.org/IBAL#Damper_17_ICP"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "Motorized damper 17"
+ "@value": "Jnc35-OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_197",
+ "@id": "http://example.org/IBAL#zs3_heat_rtd",
"@type": [
- "http://data.ashrae.org/standard223#FlowSensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "http://example.org/IBAL#Segment_105"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasValue": [
{
- "@id": "http://example.org/IBAL#ahu1_f_cc"
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "66"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@value": "Channel 197"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#Channel_106",
- "@type": [
- "http://data.ashrae.org/standard223#TemperatureSensor"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://example.org/IBAL#Segment_12"
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/value": [
{
- "@id": "http://example.org/IBAL#zs1_out_rtd"
+ "@value": "66"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 106"
+ "@value": "zs3 heat rtd"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc32-ICP2",
+ "@id": "http://example.org/IBAL#Damper_8_OCP",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_8"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc32-ICP2"
+ "@value": "Damper 8 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc32-ICP1",
+ "@id": "http://example.org/IBAL#HC_5_W_OCP",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc32-ICP1"
+ "@value": "HC 5 W OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_394ow",
+ "@id": "http://example.org/IBAL#Jnc17-OCP",
"@type": [
- "http://data.ashrae.org/standard223#Controller"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Fan_3"
+ "@id": "http://example.org/IBAL#Segment_52"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#exf1_on"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 394ow"
+ "@value": "Jnc17-OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#HC_1_ICP",
+ "@id": "http://example.org/IBAL#Segment_32",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://example.org/IBAL#Damper_7_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc11-ICP2"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#AHU_1_ICP"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "HC 1 ICP"
+ "@value": "Segment 32"
}
]
},
{
- "@id": "http://example.org/IBAL#zs2_t_sp_f",
+ "@id": "http://example.org/IBAL#Segment_96",
"@type": [
- "http://data.ashrae.org/bacnet/2020#AnalogInputObject",
- "http://data.ashrae.org/standard223#QuantifiableProperty"
- ],
- "http://data.ashrae.org/bacnet/2020#description": [
- {
- "@value": "Zone2 Temperature Setpoint"
- }
- ],
- "http://data.ashrae.org/bacnet/2020#object-identifier": [
- {
- "@value": "analog-input,6"
- }
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/bacnet/2020#object-name": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@value": "zs2_t_sp_f"
- }
- ],
- "http://data.ashrae.org/bacnet/2020#object-type": [
+ "@id": "http://example.org/IBAL#Jnc35-OCP"
+ },
{
- "@value": "analog-input"
+ "@id": "http://example.org/IBAL#WaterPump_4_ICP"
}
],
- "http://data.ashrae.org/bacnet/2020#objectOf": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#VAV_2"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
- "http://data.ashrae.org/bacnet/2020#present-value": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@type": "http://www.w3.org/2001/XMLSchema#float",
- "@value": "74.0"
+ "@value": "Segment 96"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_3_W_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Aspect-Setpoint"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@value": "HC 3 W ICP"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc10-ICP2",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_F"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "zs2 t sp f"
+ "@value": "Jnc10-ICP2"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_454",
+ "@id": "http://example.org/IBAL#Channel_450",
"@type": [
"http://data.ashrae.org/standard223#Controller"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#VFD_4"
+ "@id": "http://example.org/IBAL#VFD_2"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#exf2_vfd"
+ "@id": "http://example.org/IBAL#ahu1_vfd"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 454"
+ "@value": "Channel 450"
}
]
},
{
- "@id": "http://example.org/IBAL#VAV3_FnB",
+ "@id": "http://example.org/IBAL#Fan_1_OCP",
"@type": [
- "http://data.ashrae.org/standard223#FunctionBlock"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasInput": [
- {
- "@id": "http://example.org/IBAL#d17_pos_fb"
- },
- {
- "@id": "http://example.org/IBAL#vav3_f"
- },
- {
- "@id": "http://example.org/IBAL#vav3_out_rtd"
- },
- {
- "@id": "http://example.org/IBAL#vav3_t_in"
- },
- {
- "@id": "http://example.org/IBAL#zs3_out_rtd"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#zs3_t_sp_f"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#hasOutput": [
- {
- "@id": "http://example.org/IBAL#d17_pos_c"
- },
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://example.org/IBAL#vav3_heat_c"
+ "@id": "http://example.org/IBAL#AHU_1_OCP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "VAV3 Fn b"
+ "@value": "Fan 1 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Fan_3_E_ICP",
+ "@id": "http://example.org/IBAL#Jnc17-ICP1",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#Junction_15"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Fan 3 E ICP"
+ "@value": "Jnc17-ICP1"
}
]
},
{
- "@id": "http://example.org/IBAL#Damper_18_OCP",
+ "@id": "http://example.org/IBAL#Segment_95",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://example.org/IBAL#Jnc24-OCP2"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc35-ICP1"
}
],
- "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#MotorizedDamper_18"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Damper 18 OCP"
+ "@value": "Segment 95"
}
]
},
{
- "@id": "http://example.org/IBAL#v13_pos_c",
+ "@id": "http://example.org/IBAL#zs1_heat_rtd",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasValue": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Voltage"
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "66"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@value": "v13 pos c"
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#vav1_heat_power",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://qudt.org/schema/qudt/value": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ "@value": "66"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://qudt.org/vocab/unit/W"
+ "@value": "zs1 heat rtd"
}
- ],
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Temp_7",
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "vav1 heat power"
+ "@value": "Channel 106"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc24-OCP1",
+ "@id": "http://example.org/IBAL#Damper_10_ICP",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc24-OCP1"
+ "@value": "Damper 10 ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#Junction_17",
+ "@id": "http://example.org/IBAL#Exhaust_Fan_2_Connection_2",
"@type": [
- "http://data.ashrae.org/standard223#Junction"
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#Jnc17-ICP"
- },
+ "http://data.ashrae.org/standard223#connectsAt": [
{
- "@id": "http://example.org/IBAL#Jnc17-ICP2"
+ "@id": "http://example.org/IBAL#Damper_9_ICP"
},
{
- "@id": "http://example.org/IBAL#Jnc17-OCP"
+ "@id": "http://example.org/IBAL#Fan_4_OCP"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -5352,166 +4972,186 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Junction 17"
+ "@value": "Exhaust Fan 2 Connection 2"
}
]
},
{
- "@id": "http://example.org/IBAL#HC_5_W_OCP",
+ "@id": "http://example.org/IBAL#Channel_78",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#TemperatureSensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://example.org/IBAL#AHU_1_Connection_2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#ahu2_heat_rtd"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "HC 5 W OCP"
+ "@value": "Channel 78"
}
]
},
{
- "@id": "http://example.org/IBAL#Damper_2_ICP",
+ "@id": "http://example.org/IBAL#Junction_20",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Junction"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://example.org/IBAL#Jnc20-ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc20-OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc20-OCP2"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#VAV_2_ICP"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Damper 2 ICP"
+ "@value": "Junction 20"
}
]
},
{
- "@id": "http://example.org/IBAL#ahu2_rh_up",
+ "@id": "http://example.org/IBAL#Segment_101",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ "@id": "http://example.org/IBAL#Jnc18-ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc38-OCP"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "ahu2 rh up"
+ "@value": "Segment 101"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_38",
+ "@id": "http://example.org/IBAL#Channel_125",
"@type": [
- "http://data.ashrae.org/standard223#HumiditySensor"
+ "http://data.ashrae.org/standard223#TemperatureSensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#Segment_14"
+ "@id": "http://example.org/IBAL#Segment_106"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#zs2_rh"
+ "@id": "http://example.org/IBAL#ahu2_cc_out_rtd"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 38"
+ "@value": "Channel 125"
}
]
},
{
- "@id": "http://example.org/IBAL#Damper_4_ICP",
+ "@id": "http://example.org/IBAL#Segment_57",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://example.org/IBAL#Jnc18-OCP2"
+ },
+ {
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_1_ICP"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#VAV_4_ICP"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Damper 4 ICP"
+ "@value": "Segment 57"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_94",
+ "@id": "http://example.org/IBAL#Segment_48",
"@type": [
"http://data.ashrae.org/standard223#Connection"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Jnc34-OCP2"
+ "@id": "http://example.org/IBAL#Damper_17_ICP"
},
{
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_4_ICP_2"
+ "@id": "http://example.org/IBAL#Jnc16-OCP1"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 94"
+ "@value": "Segment 48"
}
]
},
{
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_5_OCP",
+ "@id": "http://example.org/IBAL#Segment_63",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://example.org/IBAL#Jnc22-OCP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#PlateHeatExchange_1_Lower_ICP"
}
],
- "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_5"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Motorized three way valve 5 OCP"
+ "@value": "Segment 63"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_85",
+ "@id": "http://example.org/IBAL#Segment_56",
"@type": [
"http://data.ashrae.org/standard223#Connection"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Jnc31-OCP"
+ "@id": "http://example.org/IBAL#AHU_2_G_ICP"
},
{
- "@id": "http://example.org/IBAL#Jnc32-ICP2"
+ "@id": "http://example.org/IBAL#Jnc18-OCP"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -5521,39 +5161,42 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 85"
+ "@value": "Segment 56"
}
]
},
{
- "@id": "http://example.org/IBAL#ahu2_f_cc_mag",
+ "@id": "http://example.org/IBAL#HVACZone_3",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Zone"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasDomainSpace": [
{
- "@id": "http://qudt.org/vocab/unit/GAL_US-PER-MIN"
+ "@id": "http://example.org/IBAL#HVACSpace_3"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "ahu2 f cc mag"
+ "@value": "HVACZone 3"
}
]
},
{
- "@id": "http://example.org/IBAL#CC_3_OCP",
+ "@id": "http://example.org/IBAL#Segment_14",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Connection"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#AHU_3_Connection_2"
+ "@id": "http://example.org/IBAL#HVAC_Space_2_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc5-ICP2"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -5561,256 +5204,302 @@
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#isConnectionPointOf": [
- {
- "@id": "http://example.org/IBAL#CoolingCoil_3"
- }
- ],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": " CC 3 OCP"
+ "@value": "Segment 14"
}
]
},
{
- "@id": "http://example.org/IBAL#Chiller_1_Lower_Connection",
+ "@id": "http://example.org/IBAL#Junction_21",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#Junction"
],
- "http://data.ashrae.org/standard223#connectsAt": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Chiller_1_Lower_OCP"
+ "@id": "http://example.org/IBAL#Jnc21-ICP1"
},
{
- "@id": "http://example.org/IBAL#WaterPump_2_ICP"
+ "@id": "http://example.org/IBAL#Jnc21-ICP2"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc21-OCP"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-ChilledWater"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Chiller 1 Lower Connection"
+ "@value": "Junction 21"
}
]
},
{
- "@id": "http://example.org/IBAL#HC_5_E_ICP",
+ "@id": "http://example.org/IBAL#Chiller_1_Lower_ICP",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "HC 5 E ICP"
+ "@value": "Chiller 1 Lower ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#ahu2_heat_c",
+ "@id": "http://example.org/IBAL#HC_4_E_ICP",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Voltage"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "ahu2 heat c"
+ "@value": "HC 4 E ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_308T",
+ "@id": "http://example.org/IBAL#Channel_4",
"@type": [
- "http://data.ashrae.org/standard223#TemperatureSensor"
+ "http://data.ashrae.org/standard223#PressureSensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#Segment_10"
+ "@id": "http://example.org/IBAL#AHU_2_Connection_3"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#vav4_t_in"
+ "@id": "http://example.org/IBAL#ahu1_p_up"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 308T"
+ "@value": "Channel 4"
}
]
},
{
- "@id": "http://example.org/IBAL#zs1_out_rtd",
+ "@id": "http://example.org/IBAL#Damper_13_OCP",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/bacnet/2020#description": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@value": "Zone1 Temperature"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/bacnet/2020#object-identifier": [
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
{
- "@value": "analog-input,5"
+ "@id": "http://example.org/IBAL#MotorizedDamper_13"
}
],
- "http://data.ashrae.org/bacnet/2020#object-name": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "zs1_out_rtd"
+ "@value": "Damper 13 OCP"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc4-OCP1",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/bacnet/2020#object-type": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@value": "analog-input"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/bacnet/2020#objectOf": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://example.org/IBAL#HVACZone_1"
+ "@value": "Jnc4-OCP1"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#PlateHeatExchange_1_Connection",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/bacnet/2020#present-value": [
+ "http://data.ashrae.org/standard223#connectsAt": [
{
- "@type": "http://www.w3.org/2001/XMLSchema#float",
- "@value": "70.0"
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_3_ICP_1"
+ },
+ {
+ "@id": "http://example.org/IBAL#PlateHeatExchange_1_Lower_OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-ChilledWater"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Plate Heat Exchange 1 Connection"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#VAV_4_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://example.org/IBAL#VAV_4_Connection_2"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_F"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "zs1_out_rtd"
+ "@value": "VAV 4 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_395gw",
+ "@id": "http://example.org/IBAL#Junction_23",
"@type": [
- "http://data.ashrae.org/standard223#Controller"
+ "http://data.ashrae.org/standard223#Junction"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#AHU_3"
+ "@id": "http://example.org/IBAL#Jnc23-ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc23-ICP2"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc23-OCP"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#ahu2_on"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 395gw"
+ "@value": "Junction 23"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc17-OCP",
+ "@id": "http://example.org/IBAL#Segment_79",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Connection"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Segment_52"
+ "@id": "http://example.org/IBAL#Chiller_2_Lower_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc29-OCP"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc17-OCP"
+ "@value": "Segment 79"
}
]
},
{
- "@id": "http://example.org/IBAL#Fan_4_E_ICP",
+ "@id": "http://example.org/IBAL#MotorizedDamper_19",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Damper"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
+ "@id": "http://example.org/IBAL#Damper_19_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_19_OCP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Fan 4 E ICP"
+ "@value": "Motorized damper 19"
}
]
},
{
- "@id": "http://example.org/IBAL#AHU_1_Zone",
+ "@id": "http://example.org/IBAL#HC_3_W_OCP",
"@type": [
- "http://data.ashrae.org/standard223#Zone"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://data.ashrae.org/standard223#hasDomainSpace": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://example.org/IBAL#HVACSpace_1"
- },
+ "@value": "HC 3 W OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_1_S_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#HVACSpace_2"
+ "@id": "http://data.ashrae.org/standard223#Electricity-Signal"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "AHU 1 Zone"
+ "@value": "Fan 1 S ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_5",
+ "@id": "http://example.org/IBAL#Segment_73",
"@type": [
- "http://data.ashrae.org/standard223#PressureSensor"
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Segment_9"
+ "@id": "http://example.org/IBAL#Jnc27-ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#WaterPump_1_OCP"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#ahu1_p_down"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 5"
+ "@value": "Segment 73"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc9-ICP",
+ "@id": "http://example.org/IBAL#Jnc8-ICP",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -5821,163 +5510,199 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc9-ICP"
+ "@value": "Jnc8-ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#Damper_18_ICP",
+ "@id": "http://example.org/IBAL#d15_pos_fb",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/bacnet/2020#AnalogInputObject",
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/bacnet/2020#description": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@value": "VAV1 Damper Feedback Signal"
}
],
- "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ "http://data.ashrae.org/bacnet/2020#object-identifier": [
{
- "@id": "http://example.org/IBAL#MotorizedDamper_18"
+ "@value": "analog-input,1"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/bacnet/2020#object-name": [
{
- "@value": "Damper 18 ICP"
+ "@value": "d15_pos_fb"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#Jnc1-OCP2",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/bacnet/2020#object-type": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@value": "analog-input"
+ }
+ ],
+ "http://data.ashrae.org/bacnet/2020#objectOf": [
+ {
+ "@id": "http://example.org/IBAL#VAV_1"
+ }
+ ],
+ "http://data.ashrae.org/bacnet/2020#present-value": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#float",
+ "@value": "0.0"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Voltage"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc1-OCP2"
+ "@value": "d15 pos fb"
}
]
},
{
- "@id": "http://example.org/IBAL#Junction_3",
+ "@id": "http://example.org/IBAL#Junction_33",
"@type": [
"http://data.ashrae.org/standard223#Junction"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Jnc3-ICP1"
+ "@id": "http://example.org/IBAL#Jnc33-ICP1"
},
{
- "@id": "http://example.org/IBAL#Jnc3-ICP2"
+ "@id": "http://example.org/IBAL#Jnc33-OCP"
},
{
- "@id": "http://example.org/IBAL#Jnc3-OCP"
+ "@id": "http://example.org/IBAL#Jnc33-OCP2"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Junction 3"
+ "@value": "Junction 33"
}
]
},
{
- "@id": "http://example.org/IBAL#CC_3_W_ICP",
+ "@id": "http://example.org/IBAL#Jnc21-ICP1",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Segment_61"
+ }
+ ],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "CC 3 W ICP"
+ "@value": "Jnc21-ICP1"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc36-OCP2",
+ "@id": "http://example.org/IBAL#Channel_383",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Controller"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#Segment_98"
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_1"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://example.org/IBAL#v12_pos_fb"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc36-OCP2"
+ "@value": "Channel 383"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc28-OCP2",
+ "@id": "http://example.org/IBAL#Channel_90",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#TemperatureSensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://example.org/IBAL#VAV_4_Connection_2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#vav4_out_rtd"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc28-OCP2"
+ "@value": "Channel 90"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_49",
+ "@id": "http://example.org/IBAL#Jnc38-ICP",
"@type": [
- "http://data.ashrae.org/standard223#PressureSensor"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#AHU_3_Connection_3"
+ "@id": "http://example.org/IBAL#Segment_100"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#oau_p_up"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 49"
+ "@value": "Jnc38-ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#Junction_37",
+ "@id": "http://example.org/IBAL#Jnc32-OCP",
"@type": [
- "http://data.ashrae.org/standard223#Junction"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Jnc37-ICP"
- },
+ "@id": "http://example.org/IBAL#Segment_88"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#Jnc37-OCP1"
- },
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://example.org/IBAL#Jnc37-OCP2"
+ "@value": "Jnc32-OCP"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc20-OCP2",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -5986,110 +5711,109 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Junction 37"
+ "@value": "Jnc20-OCP2"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_13",
+ "@id": "http://example.org/IBAL#Jnc36-ICP",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#Jnc19-OCP"
- },
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://example.org/IBAL#ManualTwoWayValve_2_ICP"
+ "@value": "Jnc36-ICP"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc26-ICP1",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 13"
+ "@value": "Jnc26-ICP1"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_76",
+ "@id": "http://example.org/IBAL#Channel_394ow",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#Controller"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#Jnc26-OCP"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#Jnc28-ICP"
+ "@id": "http://example.org/IBAL#Fan_3"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://example.org/IBAL#exf1_on"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 76"
+ "@value": "Channel 394ow"
}
]
},
{
- "@id": "http://example.org/IBAL#PlateHeatExchange_1_Upper_ICP",
+ "@id": "http://example.org/IBAL#d7_pos_fb",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/PositionVector"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Plate Heat Exchange 1 Upper ICP"
+ "@value": "d7 pos fb"
}
]
},
{
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_1",
+ "@id": "http://example.org/IBAL#Jnc36-OCP1",
"@type": [
- "http://data.ashrae.org/standard223#ThreeWayValve"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_1_ICP_1"
- },
- {
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_1_ICP_2"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_1_OCP"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Motorized three way valve 1"
+ "@value": "Jnc36-OCP1"
}
]
},
{
- "@id": "http://example.org/IBAL#Junction_32",
+ "@id": "http://example.org/IBAL#Junction_35",
"@type": [
"http://data.ashrae.org/standard223#Junction"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Jnc32-ICP1"
+ "@id": "http://example.org/IBAL#Jnc35-ICP1"
},
{
- "@id": "http://example.org/IBAL#Jnc32-ICP2"
+ "@id": "http://example.org/IBAL#Jnc35-ICP2"
},
{
- "@id": "http://example.org/IBAL#Jnc32-OCP"
+ "@id": "http://example.org/IBAL#Jnc35-OCP"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -6099,60 +5823,44 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Junction 32"
+ "@value": "Junction 35"
}
]
},
{
- "@id": "http://example.org/IBAL#vav1_t_in",
+ "@id": "http://example.org/IBAL#CC_3_W_ICP",
"@type": [
- "http://data.ashrae.org/bacnet/2020#AnalogInputObject",
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/bacnet/2020#description": [
- {
- "@value": "VAV1 Supply Air Temperature"
- }
- ],
- "http://data.ashrae.org/bacnet/2020#object-identifier": [
- {
- "@value": "analog-input,3"
- }
- ],
- "http://data.ashrae.org/bacnet/2020#object-name": [
- {
- "@value": "vav1_t_in"
- }
- ],
- "http://data.ashrae.org/bacnet/2020#object-type": [
- {
- "@value": "analog-input"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/bacnet/2020#objectOf": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#VAV_1"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://data.ashrae.org/bacnet/2020#present-value": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@type": "http://www.w3.org/2001/XMLSchema#float",
- "@value": "70.0"
+ "@value": "CC 3 W ICP"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Channel_302T",
+ "@type": [
+ "http://data.ashrae.org/standard223#TemperatureSensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://example.org/IBAL#Segment_4"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_F"
+ "@id": "http://example.org/IBAL#vav2_t_in"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "vav1 t in"
+ "@value": "Channel 302T"
}
]
},
@@ -6178,153 +5886,180 @@
]
},
{
- "@id": "http://example.org/IBAL#Fan_2_VFD_2",
+ "@id": "http://example.org/IBAL#Jnc33-OCP",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#Fan_2_S_ICP"
- },
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://example.org/IBAL#VFD_2_OCP"
+ "@value": "Jnc33-OCP"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#CC_3_W_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Fan 2 VFD 2"
+ "@value": "CC 3 W OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc4-OCP2",
+ "@id": "http://example.org/IBAL#Junction_18",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Junction"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc18-ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc18-OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc18-OCP2"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc4-OCP2"
+ "@value": "Junction 18"
}
]
},
{
- "@id": "http://example.org/IBAL#Chiller_2_Upper_OCP",
+ "@id": "http://example.org/IBAL#Jnc26-ICP2",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-ChilledWater"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Chiller 2 Upper OCP"
+ "@value": "Jnc26-ICP2"
}
]
},
{
- "@id": "http://example.org/IBAL#vav4_heat_c",
+ "@id": "http://example.org/IBAL#HC_6_E_ICP",
"@type": [
- "http://data.ashrae.org/bacnet/2020#AnalogOutputObject",
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/bacnet/2020#description": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@value": "VAV4 Heater Control Signal"
+ "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
}
],
- "http://data.ashrae.org/bacnet/2020#object-identifier": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "analog-output,1"
+ "@value": "HC 6 E ICP"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_6",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/bacnet/2020#object-name": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@value": "vav4_heat_c"
- }
- ],
- "http://data.ashrae.org/bacnet/2020#object-type": [
+ "@id": "http://example.org/IBAL#Damper_5_OCP"
+ },
{
- "@value": "analog-output"
+ "@id": "http://example.org/IBAL#Jnc3-ICP1"
}
],
- "http://data.ashrae.org/bacnet/2020#objectOf": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#VAV_4"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/bacnet/2020#present-value": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@type": "http://www.w3.org/2001/XMLSchema#float",
- "@value": "0.0"
+ "@value": "Segment 6"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#ahu2_in_rtd",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Voltage"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "vav4 heat c"
+ "@value": "ahu2 in rtd"
}
]
},
{
- "@id": "http://example.org/IBAL#HC_5_W_ICP",
+ "@id": "http://example.org/IBAL#Jnc6-ICP1",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "HC 5 W ICP"
+ "@value": "Jnc6-ICP1"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_336",
+ "@id": "http://example.org/IBAL#HC_2_OCP",
"@type": [
- "http://data.ashrae.org/standard223#Controller"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#MotorizedDamper_1"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://example.org/IBAL#d15_pos_fb"
+ "@id": "http://example.org/IBAL#VAV_1_OCP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 336"
+ "@value": "HC 2 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#WaterPump_1_OCP",
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_1_OCP",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -6335,35 +6070,35 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Water pump 1 OCP"
+ "@value": "Motorized three way valve 1 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Damper_13_OCP",
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_2_ICP_2",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://data.ashrae.org/standard223#isConnectionPointOf": [
{
- "@id": "http://example.org/IBAL#MotorizedDamper_13"
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_2"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Damper 13 OCP"
+ "@value": "Motorized three way valve 2 ICP 2"
}
]
},
{
- "@id": "http://example.org/IBAL#Fan_3_OCP",
+ "@id": "http://example.org/IBAL#HVAC_Space_4_ICP",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -6372,76 +6107,89 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Fan 3 OCP"
+ "@value": "HVAC Space 4 ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#Damper_9_OCP",
+ "@id": "http://example.org/IBAL#hx1_pg_rtd",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://example.org/IBAL#MotorizedDamper_9"
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "70"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Damper 9 OCP"
+ "@value": "hx1_hw_rtd"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_107",
+ "@id": "http://example.org/IBAL#Channel_193",
"@type": [
- "http://data.ashrae.org/standard223#TemperatureSensor"
+ "http://data.ashrae.org/standard223#FlowSensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#HVAC_Space_2_ICP"
+ "@id": "http://example.org/IBAL#Chiller_1_Lower_Connection"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#zs2_heat_rtd"
+ "@id": "http://example.org/IBAL#ch1_f_e"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 107"
+ "@value": "Channel 193"
}
]
},
{
- "@id": "http://example.org/IBAL#PlateHeatExchange_1_Upper_OCP",
+ "@id": "http://example.org/IBAL#Jnc36-OCP2",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Segment_98"
+ }
+ ],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Plate Heat Exchange 1 Upper OCP"
+ "@value": "Jnc36-OCP2"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_35",
+ "@id": "http://example.org/IBAL#VAV_1_Connection_2",
"@type": [
"http://data.ashrae.org/standard223#Connection"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Jnc13-ICP1"
+ "@id": "http://example.org/IBAL#HVAC_Space_1_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#VAV_1_OCP"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -6451,22 +6199,14 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 35"
+ "@value": "VAV 1 Connection 2"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_62",
+ "@id": "http://example.org/IBAL#Jnc21-OCP",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#Jnc21-OCP"
- },
- {
- "@id": "http://example.org/IBAL#Jnc23-ICP"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -6475,164 +6215,169 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 62"
+ "@value": "Jnc21-OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#exf1_p_down",
+ "@id": "http://example.org/IBAL#CC_3_ICP",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://qudt.org/vocab/unit/PA"
+ "@id": "http://example.org/IBAL#AHU_3_ICP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "exf1 p down"
+ "@value": "CC 3 ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_111",
+ "@id": "http://example.org/IBAL#Segment_94",
"@type": [
- "http://data.ashrae.org/standard223#TemperatureSensor"
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#HVAC_Space_4_ICP"
+ "@id": "http://example.org/IBAL#Jnc34-OCP2"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_4_ICP_2"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#zs4_heat_rtd"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 111"
+ "@value": "Segment 94"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_107",
+ "@id": "http://example.org/IBAL#PlateHeatExchange_1_ConnectionTemperature",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasValue": [
{
- "@id": "http://example.org/IBAL#Jnc23-ICP2"
- },
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "60"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_3_OCP"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 107"
+ "@value": "Plate heat exchange 1 Connection temperature"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_39",
+ "@id": "http://example.org/IBAL#WaterPump_1_OCP",
"@type": [
- "http://data.ashrae.org/standard223#HumiditySensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "http://example.org/IBAL#Segment_16"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#zs3_rh"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 39"
+ "@value": "Water pump 1 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#VAV_2_Connection_1",
+ "@id": "http://example.org/IBAL#oau_out_rtd",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#connectsAt": [
+ "http://data.ashrae.org/standard223#hasValue": [
{
- "@id": "http://example.org/IBAL#Damper_2_OCP"
- },
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "45"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://example.org/IBAL#HC_3_ICP"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "45"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "VAV 2 Connection 1"
+ "@value": "oau out rtd"
}
]
},
{
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_2",
+ "@id": "http://example.org/IBAL#Jnc4-ICP",
"@type": [
- "http://data.ashrae.org/standard223#ThreeWayValve"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_2_ICP_1"
- },
- {
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_2_ICP_2"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_2_OCP"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Motorized three way valve 2"
+ "@value": "Jnc4-ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#VFD_3",
+ "@id": "http://example.org/IBAL#Channel_38",
"@type": [
- "http://data.ashrae.org/standard223#VariableFrequencyDrive"
+ "http://data.ashrae.org/standard223#HumiditySensor"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#VFD_3_ICP"
- },
+ "@id": "http://example.org/IBAL#Segment_14"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#VFD_3_OCP"
+ "@id": "http://example.org/IBAL#zs2_rh"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "VFD 3"
+ "@value": "Channel 38"
}
]
},
{
- "@id": "http://example.org/IBAL#exf1_t_in",
+ "@id": "http://example.org/IBAL#ahu2_t_ra",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -6648,157 +6393,147 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "exf1 t in"
+ "@value": "ahu2 t ra"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_334",
+ "@id": "http://example.org/IBAL#Channel_37",
"@type": [
- "http://data.ashrae.org/standard223#FlowSensor"
+ "http://data.ashrae.org/standard223#HumiditySensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#Segment_20"
+ "@id": "http://example.org/IBAL#Segment_12"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#ahu2_f_ra"
+ "@id": "http://example.org/IBAL#zs1_rh"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 334"
+ "@value": "Channel 37"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_403",
+ "@id": "http://example.org/IBAL#Channel_155",
"@type": [
- "http://data.ashrae.org/standard223#Controller"
+ "http://data.ashrae.org/standard223#TemperatureSensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#HeatingCoil_5"
+ "@id": "http://example.org/IBAL#Segment_56"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#vav3_heat_c"
+ "@id": "http://example.org/IBAL#ahu2_cc_in_rtd"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 403"
+ "@value": "Channel 155"
}
]
},
{
- "@id": "http://example.org/IBAL#HC_6_W_ICP",
+ "@id": "http://example.org/IBAL#Damper_4_OCP",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "HC 6 W ICP"
+ "@value": "Damper 4 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_14",
+ "@id": "http://example.org/IBAL#vav1_f",
"@type": [
- "http://data.ashrae.org/standard223#PressureSensor"
+ "http://data.ashrae.org/bacnet/2020#AnalogInputObject",
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/bacnet/2020#description": [
{
- "@id": "http://example.org/IBAL#Exhaust_Fan_1_Connection_2"
+ "@value": "VAV1 Airflow Rate"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/bacnet/2020#object-identifier": [
{
- "@id": "http://example.org/IBAL#exf1_p_down"
+ "@value": "analog-input,4"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/bacnet/2020#object-name": [
{
- "@value": "Channel 14"
+ "@value": "VAV1-Airflow"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#VAV_2",
- "@type": [
- "http://data.ashrae.org/bacnet/2020#BACnetDevice",
- "http://data.ashrae.org/standard223#TerminalUnit"
],
- "http://data.ashrae.org/bacnet/2020#hasPort": [
+ "http://data.ashrae.org/bacnet/2020#object-type": [
{
- "@id": "http://data.ashrae.org/bacnet/2020#P_47812"
+ "@value": "analog-input"
+ }
+ ],
+ "http://data.ashrae.org/bacnet/2020#objectOf": [
+ {
+ "@id": "http://example.org/IBAL#VAV_1"
}
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "http://example.org/IBAL#HeatingCoil_3"
- },
+ "http://data.ashrae.org/bacnet/2020#present-value": [
{
- "@id": "http://example.org/IBAL#MotorizedDamper_2"
+ "@type": "http://www.w3.org/2001/XMLSchema#float",
+ "@value": "0.0"
}
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://example.org/IBAL#VAV_2_ICP"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://example.org/IBAL#VAV_2_OCP"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "VAV 2"
+ "@value": "VAV1 F"
}
]
},
{
- "@id": "http://example.org/IBAL#PlateHeatExchanger_2",
+ "@id": "http://example.org/IBAL#Channel_160",
"@type": [
- "http://data.ashrae.org/standard223#HeatExchanger"
+ "http://data.ashrae.org/standard223#TemperatureSensor"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "http://example.org/IBAL#PlateHeatExchange_2_Lower_ICP"
- },
- {
- "@id": "http://example.org/IBAL#PlateHeatExchange_2_Lower_OCP"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#PlateHeatExchange_2_Upper_ICP"
- },
+ "@id": "http://example.org/IBAL#Segment_70"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#PlateHeatExchange_2_Upper_OCP"
+ "@id": "http://example.org/IBAL#pl_in_rtd"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Plate heat exchanger 1"
+ "@value": "Channel 160"
}
]
},
{
- "@id": "http://example.org/IBAL#Damper_11_OCP",
+ "@id": "http://example.org/IBAL#Damper_14_OCP",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#Segment_35"
- }
- ],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
@@ -6806,126 +6541,126 @@
],
"http://data.ashrae.org/standard223#isConnectionPointOf": [
{
- "@id": "http://example.org/IBAL#MotorizedDamper_11"
+ "@id": "http://example.org/IBAL#MotorizedDamper_14"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Damper 11 OCP"
+ "@value": "Damper 14 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Damper_6_OCP",
+ "@id": "http://example.org/IBAL#vav2_heat_power",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#Fan_3_ICP"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
}
],
- "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://example.org/IBAL#MotorizedDamper_6"
+ "@id": "http://qudt.org/vocab/unit/W"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Damper 6 OCP"
+ "@value": "vav2 heat power"
}
]
},
{
- "@id": "http://example.org/IBAL#ahu1_f_sa",
+ "@id": "http://example.org/IBAL#vav2_out_rtd",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasValue": [
+ "http://data.ashrae.org/bacnet/2020#description": [
{
- "@type": "http://www.w3.org/2001/XMLSchema#decimal",
- "@value": "600"
+ "@value": "VAV2 Discharge Temperature"
}
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/bacnet/2020#object-identifier": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@value": "analog-input,2"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/bacnet/2020#object-name": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@value": "vav2_out_rtd"
}
],
- "http://qudt.org/schema/qudt/value": [
+ "http://data.ashrae.org/bacnet/2020#object-type": [
{
- "@value": "600"
+ "@value": "analog-input"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/bacnet/2020#objectOf": [
{
- "@value": "AHU 1 F SA"
+ "@id": "http://example.org/IBAL#VAV_2"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#Segment_32",
- "@type": [
- "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/bacnet/2020#present-value": [
{
- "@id": "http://example.org/IBAL#Damper_7_OCP"
- },
+ "@type": "http://www.w3.org/2001/XMLSchema#float",
+ "@value": "70.0"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://example.org/IBAL#Jnc11-ICP2"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 32"
+ "@value": "vav2 out rtd"
}
]
},
{
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_2_ICP_2",
+ "@id": "http://example.org/IBAL#Junction_19",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Junction"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://example.org/IBAL#Jnc19-ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc19-OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc19-OCP2"
}
],
- "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_2"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Motorized three way valve 2 ICP 2"
+ "@value": "Junction 19"
}
]
},
{
- "@id": "http://example.org/IBAL#HC_7_ICP",
+ "@id": "http://example.org/IBAL#Segment_37",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Connection"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#AHU_3_Connection_2"
+ "@id": "http://example.org/IBAL#Damper_12_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc13-ICP2"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -6935,79 +6670,84 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "HC 7 ICP"
+ "@value": "Segment 37"
}
]
},
{
- "@id": "http://example.org/IBAL#WaterPump_4",
+ "@id": "http://example.org/IBAL#Channel_328",
"@type": [
- "http://data.ashrae.org/standard223#Pump"
+ "http://data.ashrae.org/standard223#Controller"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#WaterPump_4_ICP"
- },
+ "@id": "http://example.org/IBAL#MotorizedDamper_11"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#WaterPump_4_OCP"
+ "@id": "http://example.org/IBAL#d7_pos_fb"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Water pump 4"
+ "@value": "Channel 328"
}
]
},
{
- "@id": "http://example.org/IBAL#exf1_p_up",
+ "@id": "http://example.org/IBAL#Segment_89",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ "@id": "http://example.org/IBAL#Jnc33-OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#ThermalStorage_1_ICP"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PA"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "exf1 p up"
+ "@value": "Segment 89"
}
]
},
{
- "@id": "http://example.org/IBAL#vav2_heat_c",
+ "@id": "http://example.org/IBAL#ahu1_p_down",
"@type": [
- "http://data.ashrae.org/standard223#AnalogOutputObject",
+ "http://data.ashrae.org/bacnet/2020#AnalogInputObject",
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://data.ashrae.org/bacnet/2020#description": [
{
- "@value": "VAV1 Heater Control Signal"
+ "@value": "Static Pressure Measurement Downstream Fan"
}
],
"http://data.ashrae.org/bacnet/2020#object-identifier": [
{
- "@value": "analog-output,1"
+ "@value": "analog-input,3"
}
],
"http://data.ashrae.org/bacnet/2020#object-name": [
{
- "@value": "vav2_heat_c"
+ "@value": "ahu1_p_down"
}
],
"http://data.ashrae.org/bacnet/2020#object-type": [
{
- "@value": "analog-output"
+ "@value": "analog-input"
}
],
"http://data.ashrae.org/bacnet/2020#objectOf": [
{
- "@id": "http://example.org/IBAL#VAV_2"
+ "@id": "http://example.org/IBAL#AHU_2"
}
],
"http://data.ashrae.org/bacnet/2020#present-value": [
@@ -7018,93 +6758,53 @@
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Voltage"
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/V"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "vav2 heat c"
- }
- ]
- },
- {
- "@id": "http://example.org/IBAL#HVAC_Space_3_OCP",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#Segment_16"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "HVAC Space 3 OCP"
- }
- ]
- },
- {
- "@id": "http://example.org/IBAL#Channel_64",
- "@type": [
- "http://data.ashrae.org/standard223#ElectricMeter"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "http://example.org/IBAL#HeatingCoil_3"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
- {
- "@id": "http://example.org/IBAL#vav2_heat_power"
+ "@id": "http://qudt.org/vocab/unit/PA"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 64"
+ "@value": "AHU 1 P Down"
}
]
},
- {
- "@id": "http://example.org/IBAL#Junction_36",
- "@type": [
- "http://data.ashrae.org/standard223#Junction"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#Jnc36-ICP"
- },
- {
- "@id": "http://example.org/IBAL#Jnc36-OCP1"
- },
+ {
+ "@id": "http://example.org/IBAL#vav3_heat_power",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://example.org/IBAL#Jnc36-OCP2"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://qudt.org/vocab/unit/W"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Junction 36"
+ "@value": "vav3 heat power"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc4-OCP1",
+ "@id": "http://example.org/IBAL#Segment_5",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Damper_5_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc2-OCP"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -7113,363 +6813,367 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc4-OCP1"
+ "@value": "Segment 5"
}
]
},
{
- "@id": "http://example.org/IBAL#zs4_heat_rtd",
+ "@id": "http://example.org/IBAL#zs1_rh",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://data.ashrae.org/standard223#hasValue": [
{
"@type": "http://www.w3.org/2001/XMLSchema#decimal",
- "@value": "68"
+ "@value": "80"
}
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_F"
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
"http://qudt.org/schema/qudt/value": [
{
- "@value": "68"
+ "@value": "80"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "zs4 heat rtd"
+ "@value": "zs1_rh"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_51",
+ "@id": "http://example.org/IBAL#Channel_307T",
"@type": [
- "http://data.ashrae.org/standard223#HumiditySensor"
+ "http://data.ashrae.org/standard223#TemperatureSensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#Segment_44"
+ "@id": "http://example.org/IBAL#Segment_30"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#oau_rh"
+ "@id": "http://example.org/IBAL#exf2_t_in"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 51"
+ "@value": "Channel 307T"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc11-OCP",
+ "@id": "http://example.org/IBAL#v13_pos_fb",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/bacnet/2020#AnalogInputObject",
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/bacnet/2020#description": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@value": "AHU2 Cooling Coil Feedback Signal"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/bacnet/2020#object-identifier": [
{
- "@value": "Jnc11-OCP"
+ "@value": "analog-input,2"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#Jnc31-OCP",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/bacnet/2020#object-name": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@value": "v13_pos_fb"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/bacnet/2020#object-type": [
{
- "@value": "Jnc31-OCP"
+ "@value": "analog-input"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#Channel_310AO",
- "@type": [
- "http://data.ashrae.org/standard223#Controller"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/bacnet/2020#objectOf": [
{
- "@id": "http://example.org/IBAL#MotorizedDamper_14"
+ "@id": "http://example.org/IBAL#AHU_1"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/bacnet/2020#present-value": [
{
- "@id": "http://example.org/IBAL#d5_pos_c"
+ "@type": "http://www.w3.org/2001/XMLSchema#float",
+ "@value": "0.0"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@value": "Channel 310AO"
+ "@id": "http://qudt.org/vocab/quantitykind/Voltage"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#WaterPump_2_OCP",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Water pump 2 OCP"
+ "@value": "v13 pos fb"
}
]
},
{
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_1_ICP_2",
+ "@id": "http://example.org/IBAL#VAV1_FnB",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#FunctionBlock"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasInput": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "http://example.org/IBAL#d15_pos_fb"
+ },
{
- "@value": "Motorized three way valve 1 ICP 2"
- }
- ]
- },
- {
- "@id": "http://example.org/IBAL#Segment_8",
- "@type": [
- "http://data.ashrae.org/standard223#Connection"
- ],
- "http://data.ashrae.org/standard223#cnx": [
+ "@id": "http://example.org/IBAL#vav1_f"
+ },
{
- "@id": "http://example.org/IBAL#Jnc3-ICP2"
+ "@id": "http://example.org/IBAL#vav1_out_rtd"
},
{
- "@id": "http://example.org/IBAL#Jnc4-OCP1"
+ "@id": "http://example.org/IBAL#vav1_t_in"
+ },
+ {
+ "@id": "http://example.org/IBAL#zs1_out_rtd"
+ },
+ {
+ "@id": "http://example.org/IBAL#zs1_t_sp_f"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasOutput": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://example.org/IBAL#d15_pos_c"
+ },
+ {
+ "@id": "http://example.org/IBAL#vav1_heat_c"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 8"
+ "@value": "VAV1 Fn b"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_50",
+ "@id": "http://example.org/IBAL#Channel_130",
"@type": [
- "http://data.ashrae.org/standard223#PressureSensor"
+ "http://data.ashrae.org/standard223#TemperatureSensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#Segment_44"
+ "@id": "http://example.org/IBAL#PlateHeatExchange_1_Connection"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#oau_p_down"
+ "@id": "http://example.org/IBAL#hx1_pg_rtd"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 50"
+ "@value": "Channel 130"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc17-ICP1",
+ "@id": "http://example.org/IBAL#vav3_out_rtd",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/bacnet/2020#description": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@value": "VAV3 Discharge Temperature"
}
],
- "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ "http://data.ashrae.org/bacnet/2020#object-identifier": [
{
- "@id": "http://example.org/IBAL#Junction_15"
+ "@value": "analog-input,89"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/bacnet/2020#object-name": [
{
- "@value": "Jnc17-ICP1"
+ "@value": "VAV3-T"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#Channel_360",
- "@type": [
- "http://data.ashrae.org/standard223#Controller"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/bacnet/2020#object-type": [
{
- "@id": "http://example.org/IBAL#MotorizedDamper_2"
+ "@value": "analog-input"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/bacnet/2020#objectOf": [
{
- "@id": "http://example.org/IBAL#d16_pos_fb"
+ "@id": "http://example.org/IBAL#VAV_3"
+ }
+ ],
+ "http://data.ashrae.org/bacnet/2020#present-value": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#float",
+ "@value": "55.0"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 360"
+ "@value": "vav3 out rtd"
}
]
},
{
- "@id": "http://example.org/IBAL#Junction_23",
+ "@id": "http://example.org/IBAL#AHU_3_ICP",
"@type": [
- "http://data.ashrae.org/standard223#Junction"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Jnc23-ICP"
- },
- {
- "@id": "http://example.org/IBAL#Jnc23-ICP2"
- },
- {
- "@id": "http://example.org/IBAL#Jnc23-OCP"
+ "@id": "http://example.org/IBAL#Segment_52"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Junction 23"
+ "@value": "AHU 3 ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_1",
+ "@id": "http://example.org/IBAL#Jnc38-OCP",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#AHU_1_OCP"
- },
- {
- "@id": "http://example.org/IBAL#Jnc1-ICP"
+ "@id": "http://example.org/IBAL#Segment_101"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 1"
+ "@value": "Jnc38-OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_89",
+ "@id": "http://example.org/IBAL#exf2_on",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://example.org/IBAL#Jnc33-OCP"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/Voltage"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://example.org/IBAL#ThermalStorage_1_ICP"
+ "@id": "http://qudt.org/vocab/unit/V"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "exf2 on"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Enclosure_2",
+ "@type": [
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://example.org/IBAL#HVACSpace_2"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 89"
+ "@value": "Enclosure 2"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc2-OCP",
+ "@id": "http://example.org/IBAL#HC_2_W_OCP",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc2-OCP"
+ "@value": "HC 2 W OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_51",
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_3_OCP",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#Damper_19_OCP"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#Jnc17-ICP"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_3"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 51"
+ "@value": "Motorized three way valve 3 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#d7_pos_c",
+ "@id": "http://example.org/IBAL#VAV_3_Connection_2",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositionVector"
+ "@id": "http://example.org/IBAL#HVAC_Space_3_ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#connectsAt": [
+ {
+ "@id": "http://example.org/IBAL#VAV_3_OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "d7 pos c"
+ "@value": "VAV 3 Connection 2"
}
]
},
@@ -7495,41 +7199,51 @@
]
},
{
- "@id": "http://example.org/IBAL#AHU_3_Connection_2",
+ "@id": "http://example.org/IBAL#Channel_49",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#PressureSensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://example.org/IBAL#AHU_3_Connection_3"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#oau_p_up"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "AHU 3 Connection 2"
+ "@value": "Channel 49"
}
]
},
{
- "@id": "http://example.org/IBAL#Fan_1_ICP",
+ "@id": "http://example.org/IBAL#Jnc20-ICP",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Fan 1 ICP"
+ "@value": "Jnc20-ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc7-OCP1",
+ "@id": "http://example.org/IBAL#HC_7_ICP",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#AHU_3_Connection_2"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -7538,146 +7252,157 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc7-OCP1"
+ "@value": "HC 7 ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#Chiller_1_Upper_ICP",
+ "@id": "http://example.org/IBAL#HC-1-InletTemp",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasValue": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "40"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@value": "Chiller 1 Upper ICP"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#Jnc35-ICP1",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "40"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc35-ICP1"
+ "@value": "HC 1 InletTemp"
}
]
},
{
- "@id": "http://example.org/IBAL#Junction_8",
+ "@id": "http://example.org/IBAL#Channel_128",
"@type": [
- "http://data.ashrae.org/standard223#Junction"
+ "http://data.ashrae.org/standard223#TemperatureSensor"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#Jnc8-ICP"
- },
- {
- "@id": "http://example.org/IBAL#Jnc8-OCP1"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#Jnc8-OCP2"
+ "@id": "http://example.org/IBAL#Segment_67"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://example.org/IBAL#sl_out_rtd"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Junction 8"
+ "@value": "Channel 128"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_18",
+ "@id": "http://example.org/IBAL#HC_3_OCP",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#HVAC_Space_4_OCP"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#Jnc6-ICP2"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://example.org/IBAL#VAV_2_OCP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 18"
+ "@value": "HC 3 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#zs2_rh",
+ "@id": "http://example.org/IBAL#pl_in_rtd",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasValue": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@type": "http://www.w3.org/2001/XMLSchema#decimal",
- "@value": "50"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://qudt.org/schema/qudt/value": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@value": "68"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "zs2 rh"
+ "@value": "pl in rtd"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_108",
+ "@id": "http://example.org/IBAL#Channel_122",
"@type": [
"http://data.ashrae.org/standard223#TemperatureSensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#Segment_14"
+ "@id": "http://example.org/IBAL#Chiller_1_Lower_Connection"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#zs2_out_rtd"
+ "@id": "http://example.org/IBAL#ch1_e_out_rtd"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 108"
+ "@value": "Channel 122"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc8-ICP",
+ "@id": "http://example.org/IBAL#Jnc2-OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc2-OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#CC_1_ICP",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#CoolingCoil_1"
+ }
+ ],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
@@ -7685,153 +7410,170 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc8-ICP"
+ "@value": "CC 1 ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#VFD_2",
+ "@id": "http://example.org/IBAL#VAV_4_Connection_1",
"@type": [
- "http://data.ashrae.org/standard223#VariableFrequencyDrive"
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/standard223#connectsAt": [
{
- "@id": "http://example.org/IBAL#VFD_2_ICP"
+ "@id": "http://example.org/IBAL#Damper_4_OCP"
},
{
- "@id": "http://example.org/IBAL#VFD_2_OCP"
+ "@id": "http://example.org/IBAL#HC_6_ICP"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#ahu1_vfd"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "VFD 2"
+ "@value": "VAV 4 Connection 1"
}
]
},
{
- "@id": "http://example.org/IBAL#d6_pos_fb",
+ "@id": "http://example.org/IBAL#Flow_7",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#FlowSensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositionVector"
+ "@id": "http://example.org/IBAL#VAV_3_Connection_2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#HC-5-OutletFlow"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "d6 pos fb"
+ "@value": "Flow 7"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_42",
+ "@id": "http://example.org/IBAL#HeatingCoil_4",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#HeatingCoil"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://data.ashrae.org/standard223#lnx": [
+ "@id": "http://example.org/IBAL#HC_4_E_ICP"
+ },
{
"@id": "http://example.org/IBAL#HC_4_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_4_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_4_W_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_4_W_OCP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 42"
+ "@value": "Heating coil 4"
}
]
},
{
- "@id": "http://example.org/IBAL#zs4_out_rtd",
+ "@id": "http://example.org/IBAL#Jnc23-OCP",
"@type": [
- "http://data.ashrae.org/bacnet/2020#AnalogInputObject",
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/bacnet/2020#description": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@value": "Zone4 Temperature"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
- "http://data.ashrae.org/bacnet/2020#object-identifier": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "analog-input,5"
+ "@value": "Jnc23-OCP"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Channel_121",
+ "@type": [
+ "http://data.ashrae.org/standard223#TemperatureSensor"
],
- "http://data.ashrae.org/bacnet/2020#object-name": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@value": "zs4_out_rtd"
+ "@id": "http://example.org/IBAL#Segment_76"
}
],
- "http://data.ashrae.org/bacnet/2020#object-type": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@value": "analog-input"
+ "@id": "http://example.org/IBAL#ch1_e_in_rtd"
}
],
- "http://data.ashrae.org/bacnet/2020#objectOf": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://example.org/IBAL#HVACZone_4"
+ "@value": "Channel 121"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#zs2_rh",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/bacnet/2020#present-value": [
+ "http://data.ashrae.org/standard223#hasValue": [
{
- "@type": "http://www.w3.org/2001/XMLSchema#float",
- "@value": "70.0"
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "50"
}
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_F"
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "zs4_out_rtd"
+ "@value": "zs2 rh"
}
]
},
{
- "@id": "http://example.org/IBAL#CoolingCoil_2",
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_3",
"@type": [
- "http://data.ashrae.org/standard223#CoolingCoil"
+ "http://data.ashrae.org/standard223#TwoWayValve"
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://example.org/IBAL#CC_2_ICP"
- },
- {
- "@id": "http://example.org/IBAL#CC_2_OCP"
- },
- {
- "@id": "http://example.org/IBAL#CC_2_Water_ICP"
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_3_ICP"
},
{
- "@id": "http://example.org/IBAL#CC_2_Water_OCP"
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_3_OCP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Cooling coil 2"
+ "@value": "Manual two way valve 3"
}
]
},
{
- "@id": "http://example.org/IBAL#AHU_1_OCP",
+ "@id": "http://example.org/IBAL#Jnc17-ICP2",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -7840,138 +7582,137 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "AHU 1 OCP"
+ "@value": "Jnc17-ICP2"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_307",
+ "@id": "http://example.org/IBAL#d7_pos_c",
"@type": [
- "http://data.ashrae.org/standard223#FlowSensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "http://example.org/IBAL#Segment_30"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://example.org/IBAL#exf2_f"
+ "@id": "http://qudt.org/vocab/quantitykind/PositionVector"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 307"
+ "@value": "d7 pos c"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_68",
+ "@id": "http://example.org/IBAL#Chiller_2_Upper_ICP",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#Jnc24-OCP1"
- },
- {
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_4_ICP_1"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 68"
+ "@value": "Chiller 2 Upper ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#Fan_2_OCP",
+ "@id": "http://example.org/IBAL#Channel_107",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#TemperatureSensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://example.org/IBAL#HVAC_Space_2_ICP"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#AHU_2_OCP"
+ "@id": "http://example.org/IBAL#zs2_heat_rtd"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Fan 2 OCP"
+ "@value": "Channel 107"
}
]
},
{
- "@id": "http://example.org/IBAL#Fan_1_S_ICP",
+ "@id": "http://example.org/IBAL#Segment_64",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc22-OCP2"
+ },
+ {
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_3_ICP"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Electricity-Signal"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Fan 1 S ICP"
+ "@value": "Segment 64"
}
]
},
{
- "@id": "http://example.org/IBAL#AHU_3_G_ICP",
+ "@id": "http://example.org/IBAL#Channel_363",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Controller"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://example.org/IBAL#MotorizedDamper_3"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#d17_pos_fb"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "AHU 3 G ICP"
+ "@value": "Channel 363"
}
]
},
{
- "@id": "http://example.org/IBAL#HC_3_E_ICP",
+ "@id": "http://example.org/IBAL#Damper_14_ICP",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_14"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "HC 3 E ICP"
+ "@value": "Damper 14 ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#Junction_21",
+ "@id": "http://example.org/IBAL#Jnc19-ICP",
"@type": [
- "http://data.ashrae.org/standard223#Junction"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Jnc21-ICP1"
- },
- {
- "@id": "http://example.org/IBAL#Jnc21-ICP2"
- },
- {
- "@id": "http://example.org/IBAL#Jnc21-OCP"
+ "@id": "http://example.org/IBAL#Segment_102"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -7981,118 +7722,111 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Junction 21"
+ "@value": "Jnc19-ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#ch2_e_out_rtd",
+ "@id": "http://example.org/IBAL#exf1_p_up",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_F"
+ "@id": "http://qudt.org/vocab/unit/PA"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "ch2 e out rtd"
+ "@value": "exf1 p up"
}
]
},
{
- "@id": "http://example.org/IBAL#oau_hs_rtd",
+ "@id": "http://example.org/IBAL#Chiller_1_Upper_OCP",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasValue": [
- {
- "@type": "http://www.w3.org/2001/XMLSchema#decimal",
- "@value": "60"
- }
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
- {
- "@id": "http://qudt.org/vocab/unit/DEG_F"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/value": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@value": "60"
+ "@id": "http://data.ashrae.org/standard223#Water-ChilledWater"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "oau hs rt"
+ "@value": "Chiller 1 Upper OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#ahu2_vfd",
+ "@id": "http://example.org/IBAL#Channel_456",
"@type": [
- "http://data.ashrae.org/bacnet/2020#AnalogOutputObject",
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/bacnet/2020#description": [
- {
- "@value": "AHU2 Fan Speed"
- }
- ],
- "http://data.ashrae.org/bacnet/2020#object-identifier": [
- {
- "@value": "analog-output,1"
- }
+ "http://data.ashrae.org/standard223#Controller"
],
- "http://data.ashrae.org/bacnet/2020#object-name": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@value": "ahu1_vfd"
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_5"
}
],
- "http://data.ashrae.org/bacnet/2020#object-type": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@value": "analog-output"
+ "@id": "http://example.org/IBAL#v8_pos_c"
}
],
- "http://data.ashrae.org/bacnet/2020#objectOf": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://example.org/IBAL#AHU_1"
+ "@value": "Channel 456"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc13-OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/bacnet/2020#present-value": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@type": "http://www.w3.org/2001/XMLSchema#float",
- "@value": "30.0"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Voltage"
+ "@value": "Jnc13-OCP"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#WaterChiller_2",
+ "@type": [
+ "http://data.ashrae.org/standard223#Chiller"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "http://example.org/IBAL#Chiller_2_Lower_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Chiller_2_Lower_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Chiller_2_Upper_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Chiller_2_Upper_OCP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "ahu2 vfd"
+ "@value": "Water Chiller 2"
}
]
},
{
- "@id": "http://example.org/IBAL#Damper_6_ICP",
+ "@id": "http://example.org/IBAL#PlateHeatExchange_1_Upper_ICP",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -8101,42 +7835,37 @@
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#isConnectionPointOf": [
- {
- "@id": "http://example.org/IBAL#MotorizedDamper_6"
- }
- ],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Damper 6 ICP"
+ "@value": "Plate Heat Exchange 1 Upper ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_83",
+ "@id": "http://example.org/IBAL#Channel_108",
"@type": [
"http://data.ashrae.org/standard223#TemperatureSensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#AHU_3_ICP"
+ "@id": "http://example.org/IBAL#Segment_14"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#oau_in_rtd"
+ "@id": "http://example.org/IBAL#zs2_out_rtd"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 83"
+ "@value": "Channel 108"
}
]
},
{
- "@id": "http://example.org/IBAL#WaterPump_3_OCP",
+ "@id": "http://example.org/IBAL#WaterPump_4_ICP",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -8145,404 +7874,450 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Water pump 3 OCP"
+ "@value": "Water pump 4 ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#zs1_heat_rtd",
+ "@id": "http://example.org/IBAL#Jnc25-OCP2",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasValue": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@type": "http://www.w3.org/2001/XMLSchema#decimal",
- "@value": "66"
+ "@id": "http://example.org/IBAL#Segment_71"
}
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_F"
+ "@value": "Jnc25-OCP2"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_2_S_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/value": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@value": "66"
+ "@id": "http://data.ashrae.org/standard223#Electricity-Signal"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "zs1 heat rtd"
+ "@value": "Fan 2 S ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_402",
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_5_ICP_2",
"@type": [
- "http://data.ashrae.org/standard223#Controller"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#HeatingCoil_3"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
{
- "@id": "http://example.org/IBAL#vav2_heat_c"
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_5"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 402"
+ "@value": "Motorized three way valve 5 ICP 2"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_56",
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_1",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#ThreeWayValve"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://example.org/IBAL#AHU_2_G_ICP"
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_1_ICP_1"
},
{
- "@id": "http://example.org/IBAL#Jnc18-OCP"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_1_ICP_2"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_1_OCP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 56"
+ "@value": "Motorized three way valve 1"
}
]
},
{
- "@id": "http://example.org/IBAL#HC_6_OCP",
+ "@id": "http://example.org/IBAL#Channel_5",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#PressureSensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://example.org/IBAL#Segment_9"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#VAV_4_OCP"
+ "@id": "http://example.org/IBAL#ahu1_p_down"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "HC 6 OCP"
+ "@value": "Channel 5"
}
]
},
{
- "@id": "http://example.org/IBAL#d10_pos_c",
+ "@id": "http://example.org/IBAL#ahu2_f_sa",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/A"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "d10 pos c"
+ "@value": "ahu2 f sa"
}
]
},
{
- "@id": "http://example.org/IBAL#CoolingCoil_3",
+ "@id": "http://example.org/IBAL#d5_pos_c",
"@type": [
- "http://data.ashrae.org/standard223#CoolingCoil"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://example.org/IBAL#CC_3_ICP"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/PositionVector"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://example.org/IBAL#CC_3_OCP"
- },
+ "@value": "d5 pos c"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Channel_59",
+ "@type": [
+ "http://data.ashrae.org/standard223#ElectricMeter"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#CC_3_W_ICP"
- },
+ "@id": "http://example.org/IBAL#VFD_2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#CC_3_W_OCP"
+ "@id": "http://example.org/IBAL#ahu1_fan_power"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Cooling coil 3"
+ "@value": "Channel 59"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_40",
+ "@id": "http://example.org/IBAL#Channel_307",
"@type": [
- "http://data.ashrae.org/standard223#HumiditySensor"
+ "http://data.ashrae.org/standard223#FlowSensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#Segment_18"
+ "@id": "http://example.org/IBAL#Segment_30"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#zs4_rh"
+ "@id": "http://example.org/IBAL#exf2_f"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 40"
+ "@value": "Channel 307"
}
]
},
{
- "@id": "http://example.org/IBAL#AHU_2_S_ICP",
+ "@id": "http://example.org/IBAL#Jnc9-OCP2",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Segment_27"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Electricity-Signal"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "AHU 2 S ICP"
+ "@value": "Jnc9-OCP2"
}
]
},
{
- "@id": "http://example.org/IBAL#d5_pos_c",
+ "@id": "http://example.org/IBAL#CC_2_Water_ICP",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositionVector"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "http://example.org/IBAL#AHU_2_G_ICP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "d5 pos c"
+ "@value": "CC 2 Water ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc19-ICP",
+ "@id": "http://example.org/IBAL#ahu1_rh_down",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasValue": [
{
- "@id": "http://example.org/IBAL#Segment_102"
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "50"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "50"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc19-ICP"
+ "@value": "AHU 1 RH Down"
}
]
},
{
- "@id": "http://example.org/IBAL#ThermalStorage_1",
+ "@id": "http://example.org/IBAL#Segment_99",
"@type": [
- "http://data.ashrae.org/standard223#Equipment"
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#ThermalStorage_1_ICP"
+ "@id": "http://example.org/IBAL#Jnc36-OCP1"
},
{
- "@id": "http://example.org/IBAL#ThermalStorage_1_OCP"
+ "@id": "http://example.org/IBAL#Jnc37-ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "ThermalStorage 1"
+ "@value": "Segment 99"
}
]
},
{
- "@id": "http://example.org/IBAL#HeatingCoil_2",
+ "@id": "http://example.org/IBAL#Segment_106",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil"
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "http://example.org/IBAL#HC_2_E_ICP"
- },
- {
- "@id": "http://example.org/IBAL#HC_2_ICP"
- },
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#HC_2_OCP"
+ "@id": "http://example.org/IBAL#AHU_2_G_OCP"
},
{
- "@id": "http://example.org/IBAL#HC_2_W_ICP"
- },
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_2_ICP_1"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#HC_2_W_OCP"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Heating coil 2"
+ "@value": "Segment 106"
}
]
},
{
- "@id": "http://example.org/IBAL#vav1_f",
+ "@id": "http://example.org/IBAL#Damper_18_ICP",
"@type": [
- "http://data.ashrae.org/bacnet/2020#AnalogInputObject",
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/bacnet/2020#description": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@value": "VAV1 Airflow Rate"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/bacnet/2020#object-identifier": [
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
{
- "@value": "analog-input,4"
+ "@id": "http://example.org/IBAL#MotorizedDamper_18"
}
],
- "http://data.ashrae.org/bacnet/2020#object-name": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "VAV1-Airflow"
+ "@value": "Damper 18 ICP"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_9",
+ "@type": [
+ "http://data.ashrae.org/standard223#Damper"
],
- "http://data.ashrae.org/bacnet/2020#object-type": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@value": "analog-input"
- }
- ],
- "http://data.ashrae.org/bacnet/2020#objectOf": [
+ "@id": "http://example.org/IBAL#Damper_9_ICP"
+ },
{
- "@id": "http://example.org/IBAL#VAV_1"
+ "@id": "http://example.org/IBAL#Damper_9_OCP"
}
],
- "http://data.ashrae.org/bacnet/2020#present-value": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@type": "http://www.w3.org/2001/XMLSchema#float",
- "@value": "0.0"
+ "@value": "Motorized damper 9"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_2_VFD_2",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://example.org/IBAL#Fan_2_S_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#VFD_2_OCP"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "VAV1 F"
+ "@value": "Fan 2 VFD 2"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_328AO",
+ "@id": "http://example.org/IBAL#Segment_68",
"@type": [
- "http://data.ashrae.org/standard223#Controller"
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#MotorizedDamper_11"
+ "@id": "http://example.org/IBAL#Jnc24-OCP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_4_ICP_1"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#d7_pos_c"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 328AO"
+ "@value": "Segment 68"
}
]
},
{
- "@id": "http://example.org/IBAL#d8_pos_c",
+ "@id": "http://example.org/IBAL#pl_out_rtd",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositionVector"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "d8 pos c"
+ "@value": "pl out rtd"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_363AO",
+ "@id": "http://example.org/IBAL#Junction_25",
"@type": [
- "http://data.ashrae.org/standard223#Controller"
+ "http://data.ashrae.org/standard223#Junction"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#MotorizedDamper_3"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
+ "@id": "http://example.org/IBAL#Jnc25-ICP"
+ },
{
- "@id": "http://example.org/IBAL#d17_pos_c"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "http://example.org/IBAL#Jnc25-OCP1"
+ },
{
- "@value": "Channel 363AO"
+ "@id": "http://example.org/IBAL#Jnc25-OCP2"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#WaterPump_4_OCP",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Water pump 4 OCP"
+ "@value": "Junction 25"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc10-OCP",
+ "@id": "http://example.org/IBAL#VAV_2_OCP",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -8553,562 +8328,591 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc10-OCP"
+ "@value": "VAV 2 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_307T",
+ "@id": "http://example.org/IBAL#Jnc9-ICP",
"@type": [
- "http://data.ashrae.org/standard223#TemperatureSensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "http://example.org/IBAL#Segment_30"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#exf2_t_in"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 307T"
+ "@value": "Jnc9-ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_327",
+ "@id": "http://example.org/IBAL#Channel_335AO",
"@type": [
- "http://data.ashrae.org/standard223#FlowSensor"
+ "http://data.ashrae.org/standard223#Controller"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasObservtaionLocation": [
{
- "@id": "http://example.org/IBAL#Segment_39"
+ "@id": "http://example.org/IBAL#MotorizedDamper_12"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#ahu2_f_sa"
+ "@id": "http://example.org/IBAL#d8_pos_c"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 327"
+ "@value": "Channel 335AO"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_80",
+ "@id": "http://example.org/IBAL#Junction_24",
"@type": [
- "http://data.ashrae.org/standard223#TemperatureSensor"
+ "http://data.ashrae.org/standard223#Junction"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Segment_1"
+ "@id": "http://example.org/IBAL#Jnc24-ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc24-OCP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc24-OCP2"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#ahu2_out_rtd"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 80"
+ "@value": "Junction 24"
}
]
},
{
- "@id": "http://example.org/IBAL#Damper_1_ICP",
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_1_ICP",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "http://example.org/IBAL#VAV_1_ICP"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Damper 1 ICP"
+ "@value": "Manual two way valve 1 ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#d7_pos_fb",
+ "@id": "http://example.org/IBAL#ThermalStorage_1_OCP",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositionVector"
+ "@id": "http://data.ashrae.org/standard223#Water-ChilledWater"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "d7 pos fb"
+ "@value": "Thermal Storage 1 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_5_ICP_2",
+ "@id": "http://example.org/IBAL#AHU_1",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#AirHandlingUnit"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ],
- "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ "@id": "http://example.org/IBAL#CoolingCoil_1"
+ },
{
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_5"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "http://example.org/IBAL#Fan_1"
+ },
{
- "@value": "Motorized three way valve 5 ICP 2"
+ "@id": "http://example.org/IBAL#HeatingCoil_1"
+ },
+ {
+ "@id": "http://example.org/IBAL#VFD_1"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#HeatingCoil_3",
- "@type": [
- "http://data.ashrae.org/standard223#HeatingCoil"
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://example.org/IBAL#HC_3_E_ICP"
+ "@id": "http://example.org/IBAL#AHU_1_G_ICP"
},
{
- "@id": "http://example.org/IBAL#HC_3_ICP"
+ "@id": "http://example.org/IBAL#AHU_1_G_OCP"
},
{
- "@id": "http://example.org/IBAL#HC_3_OCP"
+ "@id": "http://example.org/IBAL#AHU_1_ICP"
},
{
- "@id": "http://example.org/IBAL#HC_3_W_ICP"
+ "@id": "http://example.org/IBAL#AHU_1_OCP"
},
{
- "@id": "http://example.org/IBAL#HC_3_W_OCP"
+ "@id": "http://example.org/IBAL#AHU_1_S_ICP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Heating coil 3"
+ "@value": "AHU 1"
}
]
},
{
- "@id": "http://example.org/IBAL#zs1_t_sp_f",
+ "@id": "http://example.org/IBAL#Junction_16",
"@type": [
- "http://data.ashrae.org/bacnet/2020#AnalogInputObject",
- "http://data.ashrae.org/standard223#QuantifiableProperty"
+ "http://data.ashrae.org/standard223#Junction"
],
- "http://data.ashrae.org/bacnet/2020#description": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@value": "Zone1 Temperature Setpoint"
- }
- ],
- "http://data.ashrae.org/bacnet/2020#object-identifier": [
+ "@id": "http://example.org/IBAL#Jnc16-ICP"
+ },
{
- "@value": "analog-input,6"
+ "@id": "http://example.org/IBAL#Jnc16-OCP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc16-OCP2"
}
],
- "http://data.ashrae.org/bacnet/2020#object-name": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@value": "zs1_t_sp_f"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/bacnet/2020#object-type": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "analog-input"
+ "@value": "Junction 16"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Channel_17",
+ "@type": [
+ "http://data.ashrae.org/standard223#PressureSensor"
],
- "http://data.ashrae.org/bacnet/2020#objectOf": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#VAV_1"
+ "@id": "http://example.org/IBAL#Exhaust_Fan_2_Connection_2"
}
],
- "http://data.ashrae.org/bacnet/2020#present-value": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@type": "http://www.w3.org/2001/XMLSchema#float",
- "@value": "74.0"
+ "@id": "http://example.org/IBAL#exf2_p_down"
}
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://data.ashrae.org/standard223#Aspect-Setpoint"
+ "@value": "Channel 17"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Channel_302",
+ "@type": [
+ "http://data.ashrae.org/standard223#FlowSensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://example.org/IBAL#Segment_4"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_F"
+ "@id": "http://example.org/IBAL#vav2_f"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "zs1 t sp f"
+ "@value": "Channel 302"
}
]
},
{
- "@id": "http://example.org/IBAL#CoolingCoil_1",
+ "@id": "http://example.org/IBAL#Channel_39",
"@type": [
- "http://data.ashrae.org/standard223#CoolingCoil"
+ "http://data.ashrae.org/standard223#HumiditySensor"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "http://example.org/IBAL#CC_1_Water_ICP"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#CC_1_Water_OCP"
+ "@id": "http://example.org/IBAL#Segment_16"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Cooling"
+ "@id": "http://example.org/IBAL#zs3_rh"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Cooling coil 1"
+ "@value": "Channel 39"
}
]
},
{
- "@id": "http://example.org/IBAL#ThermalStorage_1_ICP",
+ "@id": "http://example.org/IBAL#Segment_70",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Connection"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Segment_89"
+ "@id": "http://example.org/IBAL#Jnc25-OCP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#PlateHeatExchange_2_Lower_ICP"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Thermal Storage 1 ICP"
+ "@value": "Segment 70"
}
]
},
{
- "@id": "http://example.org/IBAL#VFD_4",
+ "@id": "http://example.org/IBAL#Damper_15_OCP",
"@type": [
- "http://data.ashrae.org/standard223#VariableFrequencyDrive"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#VFD_4_ICP"
- },
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
{
- "@id": "http://example.org/IBAL#VFD_4_OCP"
+ "@id": "http://example.org/IBAL#MotorizedDamper_15"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "VFD 4"
+ "@value": "Damper 15 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_327T",
+ "@id": "http://example.org/IBAL#Channel_74",
"@type": [
"http://data.ashrae.org/standard223#TemperatureSensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#Segment_39"
+ "@id": "http://example.org/IBAL#AHU_2_Connection_2"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#ahu2_t_sa"
+ "@id": "http://example.org/IBAL#ahu1_heat_rtd"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 327T"
+ "@value": "Channel 74"
}
]
},
{
- "@id": "http://example.org/IBAL#Chiller_1_Upper_OCP",
+ "@id": "http://example.org/IBAL#VFD_3",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#VariableFrequencyDrive"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Water-ChilledWater"
+ "@id": "http://example.org/IBAL#VFD_3_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#VFD_3_OCP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Chiller 1 Upper OCP"
+ "@value": "VFD 3"
}
]
},
{
- "@id": "http://example.org/IBAL#Enclosure_4",
+ "@id": "http://example.org/IBAL",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://www.w3.org/2002/07/owl#Ontology"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://www.w3.org/2002/07/owl#imports": [
{
- "@id": "http://example.org/IBAL#HVACSpace_4"
+ "@id": "http://data.ashrae.org/standard223/1.0/model/all"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://www.w3.org/2002/07/owl#versionInfo": [
{
- "@value": "Enclosure 4"
+ "@value": "Created with TopBraid Composer"
}
]
},
{
- "@id": "http://example.org/IBAL#VFD_2_ICP",
+ "@id": "http://example.org/IBAL#Channel_60",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#ElectricMeter"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
+ "@id": "http://example.org/IBAL#VFD_1"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#ahu2_fan_power"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "VFD 2 ICP"
+ "@value": "Channel 60"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc5-OCP",
+ "@id": "http://example.org/IBAL#HC_6_W_ICP",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc5-OCP"
+ "@value": "HC 6 W ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#MotorizedDamper_18",
+ "@id": "http://example.org/IBAL#ahu2_heat_rtd",
"@type": [
- "http://data.ashrae.org/standard223#Damper"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://example.org/IBAL#Damper_18_ICP"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://example.org/IBAL#Damper_18_OCP"
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Motorized damper 18"
+ "@value": "ahu2 heat rtd"
}
]
},
{
- "@id": "http://example.org/IBAL#Damper_14_OCP",
+ "@id": "http://example.org/IBAL#AHU_2_ICP",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://example.org/IBAL#Segment_42"
}
],
- "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#MotorizedDamper_14"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Damper 14 OCP"
+ "@value": "AHU 2 ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_10",
+ "@id": "http://example.org/IBAL#VAV_1_Connection_1",
"@type": [
- "http://data.ashrae.org/standard223#HumiditySensor"
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#connectsAt": [
{
- "@id": "http://example.org/IBAL#Segment_1"
+ "@id": "http://example.org/IBAL#Damper_1_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_2_ICP"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#ahu2_rh_down"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 10"
+ "@value": "VAV 1 Connection 1"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc26-ICP2",
+ "@id": "http://example.org/IBAL#VFD_4_OCP",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc26-ICP2"
+ "@value": "VFD 4 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#HC_1_E_ICP",
+ "@id": "http://example.org/IBAL#ahu1_f_cc",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasValue": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "40"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@value": "HC 1 E ICP"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#Fan_5_OCP",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/GAL_US-PER-MIN"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/value": [
{
- "@id": "http://example.org/IBAL#AHU_3_OCP"
+ "@value": "40"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Fan 5 OCP"
+ "@value": "Channel 197"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc34-OCP2",
+ "@id": "http://example.org/IBAL#HC_5_W_ICP",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc34-OCP2"
+ "@value": "HC 5 W ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#Damper_15_OCP",
+ "@id": "http://example.org/IBAL#Segment_78",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Chiller_1_Lower_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc28-OCP2"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 78"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_4",
+ "@type": [
+ "http://data.ashrae.org/standard223#Damper"
],
- "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://example.org/IBAL#MotorizedDamper_15"
+ "@id": "http://example.org/IBAL#d18_pos_c"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@value": "Damper 15 OCP"
+ "@id": "http://example.org/IBAL#Damper_4_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_4_OCP"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#ManualTwoWayValve_3_OCP",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@value": "IBAL:VAV4_ICP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Manual two way valve 3 OCP"
+ "@value": "Motorized damper 4"
}
]
},
{
- "@id": "http://example.org/IBAL#ch1_power",
+ "@id": "http://example.org/IBAL#Channel_328AO",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Controller"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ "@id": "http://example.org/IBAL#MotorizedDamper_11"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/W"
+ "@id": "http://example.org/IBAL#d7_pos_c"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "ch1 power"
+ "@value": "Channel 328AO"
}
]
},
{
- "@id": "http://example.org/IBAL#CC_1_OCP",
+ "@id": "http://example.org/IBAL#Segment_4",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Connection"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#CoolingCoil_1"
+ "@id": "http://example.org/IBAL#Jnc2-OCP2"
+ },
+ {
+ "@id": "http://example.org/IBAL#VAV_2_ICP"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -9118,118 +8922,107 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": " CC 1 OCP"
+ "@value": "Segment 4"
}
]
},
{
- "@id": "http://example.org/IBAL#VFD_5_ICP",
+ "@id": "http://example.org/IBAL#d17_pos_c",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/bacnet/2020#AnalogOutputObject",
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/bacnet/2020#description": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
+ "@value": "VAV3 Damper Control Signal"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/bacnet/2020#object-identifier": [
{
- "@value": "VFD 5 ICP"
+ "@value": "analog-output,2"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#vav2_heat_power",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/bacnet/2020#object-name": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ "@value": "d17_pos_c"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/bacnet/2020#object-type": [
{
- "@id": "http://qudt.org/vocab/unit/W"
+ "@value": "analog-output"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/bacnet/2020#objectOf": [
{
- "@value": "vav2 heat power"
+ "@id": "http://example.org/IBAL#VAV_3"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#Channel_123",
- "@type": [
- "http://data.ashrae.org/standard223#TemperatureSensor"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/bacnet/2020#present-value": [
{
- "@id": "http://example.org/IBAL#Chiller_2_Lower_Connection"
+ "@type": "http://www.w3.org/2001/XMLSchema#float",
+ "@value": "0.0"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://example.org/IBAL#ch2_e_out_rtd"
+ "@id": "http://qudt.org/vocab/quantitykind/Voltage"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 123"
+ "@value": "d17 pos c"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_395bw",
+ "@id": "http://example.org/IBAL#exf1_t_in",
"@type": [
- "http://data.ashrae.org/standard223#Controller"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://example.org/IBAL#AHU_3"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://example.org/IBAL#ahu1_on"
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 395bw"
+ "@value": "exf1 t in"
}
]
},
{
- "@id": "http://example.org/IBAL#VAV_2_ICP",
+ "@id": "http://example.org/IBAL#sl_out_rtd",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@value": "VAV 2 ICP"
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#Jnc12-OCP1",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/value": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@value": "64"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc12-OCP1"
+ "@value": "sl out rtd"
}
]
},
@@ -9253,269 +9046,235 @@
]
},
{
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_1_ICP_1",
+ "@id": "http://example.org/IBAL#vav4_heat_power",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#Segment_105"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
}
],
- "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_1"
+ "@id": "http://qudt.org/vocab/unit/W"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Motorized three way valve 1 ICP 1"
+ "@value": "vav4 heat power"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc31-ICP2",
+ "@id": "http://example.org/IBAL#Fan_4_OCP",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc31-ICP2"
+ "@value": "Fan 4 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc30-ICP2",
+ "@id": "http://example.org/IBAL#Damper_12_ICP",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "Jnc30-ICP2"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#Jnc3-ICP1",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://example.org/IBAL#MotorizedDamper_12"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc3-ICP1"
+ "@value": "Damper 12 ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_4",
+ "@id": "http://example.org/IBAL#Channel_325",
"@type": [
- "http://data.ashrae.org/standard223#ThreeWayValve"
+ "http://data.ashrae.org/standard223#FlowSensor"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_4_ICP_1"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_4_ICP_2"
- },
+ "@id": "http://example.org/IBAL#Segment_23"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_4_OCP"
+ "@id": "http://example.org/IBAL#ahu1_f_ra"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Motorized three way valve 4"
+ "@value": "Channel 325"
}
]
},
{
- "@id": "http://example.org/IBAL#VAV_1_Connection_2",
+ "@id": "http://example.org/IBAL#Segment_75",
"@type": [
"http://data.ashrae.org/standard223#Connection"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#HVAC_Space_1_ICP"
+ "@id": "http://example.org/IBAL#Jnc26-ICP2"
},
{
- "@id": "http://example.org/IBAL#VAV_1_OCP"
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_4_OCP"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "VAV 1 Connection 2"
+ "@value": "Segment 75"
}
]
},
{
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_2_ICP_1",
+ "@id": "http://example.org/IBAL#Segment_59",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Connection"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Segment_106"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
- }
- ],
- "http://data.ashrae.org/standard223#isConnectionPointOf": [
- {
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_2"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "http://example.org/IBAL#Jnc21-ICP2"
+ },
{
- "@value": "Motorized three way valve 2 ICP 1"
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_1_OCP"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#VFD_5_OCP",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "VFD 5 OCP"
+ "@value": "Segment 59"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc26-OCP",
+ "@id": "http://example.org/IBAL#HC_4_W_OCP",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#Segment_76"
- }
- ],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc26-OCP"
+ "@value": "HC 4 W OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc15-ICP",
+ "@id": "http://example.org/IBAL#ahu1_fan_power",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/W"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc15-ICP"
+ "@value": "AHU1 Fan Power"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_61",
+ "@id": "http://example.org/IBAL#Segment_30",
"@type": [
- "http://data.ashrae.org/standard223#ElectricMeter"
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#HeatingCoil_4"
+ "@id": "http://example.org/IBAL#Fan_4_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc10-OCP"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#ahu1_heat_power"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 61"
+ "@value": "Segment 30"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_453",
+ "@id": "http://example.org/IBAL#Segment_104",
"@type": [
- "http://data.ashrae.org/standard223#Controller"
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#connectsAt": [
{
- "@id": "http://example.org/IBAL#VFD_3"
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_5_ICP_1"
+ },
+ {
+ "@id": "http://example.org/IBAL#ThermalStorage_1_OCP"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#exf1_vfd"
+ "@id": "http://data.ashrae.org/standard223#Water-ChilledWater"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 453"
+ "@value": "Segment 104"
}
]
},
{
- "@id": "http://example.org/IBAL#exf1_f",
+ "@id": "http://example.org/IBAL#Jnc11-ICP2",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "exf1 f"
+ "@value": "Jnc11-ICP2"
}
]
},
{
- "@id": "http://example.org/IBAL#AHU_1_G_OCP",
+ "@id": "http://example.org/IBAL#Jnc24-OCP1",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -9526,14 +9285,14 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "AHU 1 G OCP"
+ "@value": "Jnc24-OCP1"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc3-OCP",
+ "@id": "http://example.org/IBAL#HVAC_Space_1_ICP",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -9542,66 +9301,79 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc3-OCP"
+ "@value": "HVAC Space 1 ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#VAV_1",
+ "@id": "http://example.org/IBAL#Segment_92",
"@type": [
- "http://data.ashrae.org/bacnet/2020#BACnetDevice",
- "http://data.ashrae.org/standard223#TerminalUnit"
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/bacnet/2020#hasPort": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/bacnet/2020#P_47811"
+ "@id": "http://example.org/IBAL#Jnc34-ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_5_OCP"
}
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#HeatingCoil_2"
- },
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://example.org/IBAL#MotorizedDamper_1"
+ "@value": "Segment 92"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#ahu2_t_sa",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://example.org/IBAL#VAV_1_ICP"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://example.org/IBAL#VAV_1_OCP"
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "VAV 1"
+ "@value": "ahu 2 t sa"
}
]
},
{
- "@id": "http://example.org/IBAL#Damper_16_OCP",
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_3",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#ThreeWayValve"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_3_ICP_1"
+ },
{
- "@id": "http://example.org/IBAL#MotorizedDamper_16"
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_3_ICP_2"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_3_OCP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Damper 16 OCP"
+ "@value": "Motorized three way valve 3"
}
]
},
{
- "@id": "http://example.org/IBAL#Damper_12_ICP",
+ "@id": "http://example.org/IBAL#Damper_15_ICP",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -9610,100 +9382,93 @@
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#isConnectionPointOf": [
- {
- "@id": "http://example.org/IBAL#MotorizedDamper_12"
- }
- ],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Damper 12 ICP"
+ "@value": "Damper 15 ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_77",
+ "@id": "http://example.org/IBAL#ahu1_p_up",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasValue": [
{
- "@id": "http://example.org/IBAL#Jnc28-OCP1"
- },
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "11296"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://example.org/IBAL#Jnc29-ICP"
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://qudt.org/vocab/unit/PA"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "11296"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 77"
+ "@value": "AHU1 P Up"
}
]
},
{
- "@id": "http://example.org/IBAL#Damper_19_ICP",
+ "@id": "http://example.org/IBAL#Channel_40",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#MotorizedDamper_19"
- }
+ "http://data.ashrae.org/standard223#HumiditySensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://example.org/IBAL#Segment_18"
}
],
- "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#MotorizedDamper_19"
+ "@id": "http://example.org/IBAL#zs4_rh"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Damper 19 ICP"
+ "@value": "Channel 40"
}
]
},
{
- "@id": "http://example.org/IBAL#Fan_1_VFD_1",
+ "@id": "http://example.org/IBAL#Exhaust_Fan_1_Connection_2",
"@type": [
"http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#connectsAt": [
{
- "@id": "http://example.org/IBAL#Fan_1_S_ICP"
+ "@id": "http://example.org/IBAL#Damper_7_ICP"
},
{
- "@id": "http://example.org/IBAL#VFD_1_OCP"
+ "@id": "http://example.org/IBAL#Fan_3_OCP"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Electricity-Signal"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Fan 1 to VFD 1"
+ "@value": "Exhaust Fan 1 Connection 2"
}
]
},
{
- "@id": "http://example.org/IBAL#HVAC_Space_4_OCP",
+ "@id": "http://example.org/IBAL#Jnc14-ICP1",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#Segment_18"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -9712,139 +9477,187 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "HVAC Space 4 OCP"
+ "@value": "Jnc14-ICP1"
}
]
},
{
- "@id": "http://example.org/IBAL#CC_2_ICP",
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_4_OCP",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://data.ashrae.org/standard223#isConnectionPointOf": [
{
- "@id": "http://example.org/IBAL#CoolingCoil_2"
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_4"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "CC 2 ICP"
+ "@value": "Motorized three way valve 4 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#d16_pos_fb",
+ "@id": "http://example.org/IBAL#ahu1_vfd",
"@type": [
- "http://data.ashrae.org/bacnet/2020#AnalogInputObject",
+ "http://data.ashrae.org/bacnet/2020#AnalogOutputObject",
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://data.ashrae.org/bacnet/2020#description": [
{
- "@value": "VAV2 Damper Feedback Signal"
+ "@value": "AHU1 Fan Speed"
}
],
"http://data.ashrae.org/bacnet/2020#object-identifier": [
{
- "@value": "analog-input,1"
+ "@value": "analog-output,1"
}
],
"http://data.ashrae.org/bacnet/2020#object-name": [
{
- "@value": "d16_pos_fb"
+ "@value": "ahu1_vfd"
}
],
"http://data.ashrae.org/bacnet/2020#object-type": [
{
- "@value": "analog-input"
+ "@value": "analog-output"
}
],
"http://data.ashrae.org/bacnet/2020#objectOf": [
{
- "@id": "http://example.org/IBAL#VAV_2"
+ "@id": "http://example.org/IBAL#AHU_2"
+ }
+ ],
+ "http://data.ashrae.org/bacnet/2020#present-value": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#float",
+ "@value": "30.0"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Voltage"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/V"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "ahu1 vfd"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_1",
+ "@type": [
+ "http://data.ashrae.org/standard223#TwoWayValve"
],
- "http://data.ashrae.org/bacnet/2020#present-value": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@type": "http://www.w3.org/2001/XMLSchema#float",
- "@value": "0.0"
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_1_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_1_OCP"
}
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Voltage"
+ "@value": "Manual two way valve 1"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc15-OCP2",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "d16 pos fb"
+ "@value": "Jnc15-OCP2"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc18-ICP",
+ "@id": "http://example.org/IBAL#Channel_395bw",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Controller"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://example.org/IBAL#AHU_3"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#ahu1_on"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc18-ICP"
+ "@value": "Channel 395bw"
}
]
},
{
- "@id": "http://example.org/IBAL#ahu2_cc_out_rtd",
+ "@id": "http://example.org/IBAL#Segment_71",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://example.org/IBAL#Jnc25-OCP2"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc26-ICP1"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_F"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "ahu2 cc out rtd"
+ "@value": "Segment 71"
}
]
},
{
- "@id": "http://example.org/IBAL#VFD_1_ICP",
+ "@id": "http://example.org/IBAL#Jnc23-ICP2",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Segment_107"
+ }
+ ],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "VFD 1 ICP"
+ "@value": "Jnc23-ICP2"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc13-OCP",
+ "@id": "http://example.org/IBAL#Jnc1-OCP2",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -9855,42 +9668,48 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc13-OCP"
+ "@value": "Jnc1-OCP2"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_92",
+ "@id": "http://example.org/IBAL#Segment_51",
"@type": [
"http://data.ashrae.org/standard223#Connection"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Jnc34-ICP"
+ "@id": "http://example.org/IBAL#Damper_19_OCP"
},
{
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_5_OCP"
+ "@id": "http://example.org/IBAL#Jnc17-ICP"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 92"
+ "@value": "Segment 51"
}
]
},
{
- "@id": "http://example.org/IBAL#VAV_1_OCP",
+ "@id": "http://example.org/IBAL#Junction_5",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Junction"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#VAV_1_Connection_2"
+ "@id": "http://example.org/IBAL#Jnc5-ICP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc5-ICP2"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc5-OCP"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -9900,21 +9719,15 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "VAV 1 OCP"
+ "@value": "Junction 5"
}
]
},
{
- "@id": "http://example.org/IBAL#ahu1_f_ra",
+ "@id": "http://example.org/IBAL#ahu2_f_cc_mag",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasValue": [
- {
- "@type": "http://www.w3.org/2001/XMLSchema#decimal",
- "@value": "1000"
- }
- ],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
"@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
@@ -9922,168 +9735,167 @@
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
- }
- ],
- "http://qudt.org/schema/qudt/value": [
- {
- "@value": "1000"
+ "@id": "http://qudt.org/vocab/unit/GAL_US-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "AHU 1 F RA"
+ "@value": "ahu2 f cc mag"
}
]
},
{
- "@id": "http://example.org/IBAL#Damper_3_OCP",
+ "@id": "http://example.org/IBAL#PlateHeatExchanger_1",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#HeatExchanger"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://example.org/IBAL#PlateHeatExchange_1_Lower_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#PlateHeatExchange_1_Lower_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#PlateHeatExchange_1_Upper_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#PlateHeatExchange_1_Upper_OCP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Damper 3 OCP"
+ "@value": "Plate heat exchanger 1"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_335",
+ "@id": "http://example.org/IBAL#Jnc11-ICP1",
"@type": [
- "http://data.ashrae.org/standard223#Controller"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "http://example.org/IBAL#MotorizedDamper_12"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#d8_pos_fb"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 335"
+ "@value": "Jnc11-ICP1"
}
]
},
{
- "@id": "http://example.org/IBAL#d6_pos_c",
+ "@id": "http://example.org/IBAL#AHU_3_G_OCP",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositionVector"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "d6 pos c"
+ "@value": "AHU 3 G OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#zs4_rh",
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_5",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#ThreeWayValve"
],
- "http://data.ashrae.org/standard223#hasValue": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@type": "http://www.w3.org/2001/XMLSchema#decimal",
- "@value": "30"
- }
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_5_ICP_1"
+ },
{
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_5_ICP_2"
+ },
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_5_OCP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "zsh4 rh"
+ "@value": "Motorized three way valve 5"
}
]
},
{
- "@id": "http://example.org/IBAL#Damper_1_OCP",
+ "@id": "http://example.org/IBAL#PlateHeatExchange_2_Lower_OCP",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Damper 1 OCP"
+ "@value": "Plate Heat Exchange 2 Lower OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc22-ICP",
+ "@id": "http://example.org/IBAL#Damper_8_ICP",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_8"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc22-ICP"
+ "@value": "Damper 8 ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_102",
+ "@id": "http://example.org/IBAL#AHU_1_S_ICP",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#Jnc19-ICP"
- },
- {
- "@id": "http://example.org/IBAL#Jnc37-OCP2"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://data.ashrae.org/standard223#Electricity-Signal"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 102"
+ "@value": "AHU 1 S ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_88",
+ "@id": "http://example.org/IBAL#Jnc5-ICP2",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#Jnc32-OCP"
- },
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://example.org/IBAL#Jnc33-ICP1"
+ "@value": "Jnc5-ICP2"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc29-OCP2",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -10092,54 +9904,54 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 88"
+ "@value": "Jnc29-OCP2"
}
]
},
{
- "@id": "http://example.org/IBAL#MotorizedDamper_12",
+ "@id": "http://example.org/IBAL#AHU_3_OCP",
"@type": [
- "http://data.ashrae.org/standard223#Damper"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Damper_12_ICP"
- },
+ "@id": "http://example.org/IBAL#Segment_44"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#Damper_12_OCP"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Motorized damper 12"
+ "@value": "AHU 3 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#AHU_2_ICP",
+ "@id": "http://example.org/IBAL#MotorizedDamper_2",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Damper"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://example.org/IBAL#Segment_42"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "http://example.org/IBAL#Damper_2_ICP"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://example.org/IBAL#Damper_2_OCP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "AHU 2 ICP"
+ "@value": "Motorized damper 2"
}
]
},
{
- "@id": "http://example.org/IBAL#ManualTwoWayValve_1_OCP",
+ "@id": "http://example.org/IBAL#Chiller_2_Lower_ICP",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -10148,38 +9960,30 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Manual two way valve 1 OCP"
+ "@value": "Chiller 2 Lower ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#ManualTwoWayValve_4_OCP",
+ "@id": "http://example.org/IBAL#Jnc7-OCP1",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Manual two way valve 4 OCP"
+ "@value": "Jnc7-OCP1"
}
]
},
{
- "@id": "http://example.org/IBAL#VAV_4_Connection_1",
+ "@id": "http://example.org/IBAL#HVAC_Space_3_ICP",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
- ],
- "http://data.ashrae.org/standard223#connectsAt": [
- {
- "@id": "http://example.org/IBAL#Damper_4_OCP"
- },
- {
- "@id": "http://example.org/IBAL#HC_6_ICP"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -10188,75 +9992,82 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "VAV 4 Connection 1"
+ "@value": "HVAC Space 3 ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc23-ICP",
+ "@id": "http://example.org/IBAL#HeatingCoil_2",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#HeatingCoil"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://example.org/IBAL#Segment_62"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "http://example.org/IBAL#HC_2_E_ICP"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://example.org/IBAL#HC_2_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_2_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_2_W_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_2_W_OCP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc23-ICP"
+ "@value": "Heating coil 2"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_122",
+ "@id": "http://example.org/IBAL#Channel_75",
"@type": [
"http://data.ashrae.org/standard223#TemperatureSensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#Chiller_1_Lower_Connection"
+ "@id": "http://example.org/IBAL#AHU_2_Connection_3"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#ch1_e_out_rtd"
+ "@id": "http://example.org/IBAL#ahu1_cc_rtd"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 122"
+ "@value": "Channel 75"
}
]
},
{
- "@id": "http://example.org/IBAL#d11_pos_c",
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_3_ICP_2",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
{
- "@id": "http://qudt.org/vocab/unit/A"
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_3"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "d11 pos c"
+ "@value": "Motorized three way valve 3 ICP 2"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc5-ICP2",
+ "@id": "http://example.org/IBAL#VAV_3_ICP",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -10267,331 +10078,344 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc5-ICP2"
+ "@value": "VAV 3 ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#Damper_3_ICP",
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_1_ICP_2",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "http://example.org/IBAL#VAV_3_ICP"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Damper 3 ICP"
+ "@value": "Motorized three way valve 1 ICP 2"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc36-OCP1",
+ "@id": "http://example.org/IBAL#HVAC_Space_2_OCP",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Segment_14"
+ }
+ ],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc36-OCP1"
+ "@value": "HVAC Space2 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_8",
+ "@id": "http://example.org/IBAL#Channel_9",
"@type": [
"http://data.ashrae.org/standard223#PressureSensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#AHU_1_Connection_3"
+ "@id": "http://example.org/IBAL#Segment_1"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#ahu2_p_up"
+ "@id": "http://example.org/IBAL#ahu2_p_down"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 8"
+ "@value": "Channel 9"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc28-OCP1",
+ "@id": "http://example.org/IBAL#MotorizedDamper_1",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Damper"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://example.org/IBAL#Segment_77"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "http://example.org/IBAL#Damper_1_ICP"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://example.org/IBAL#Damper_1_OCP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc28-OCP1"
+ "@value": "Motorized damper 1"
}
]
},
{
- "@id": "http://example.org/IBAL#Enclosure_2",
+ "@id": "http://example.org/IBAL#d8_pos_c",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://example.org/IBAL#HVACSpace_2"
+ "@id": "http://qudt.org/vocab/quantitykind/PositionVector"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Enclosure 2"
+ "@value": "d8 pos c"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc20-OCP",
+ "@id": "http://example.org/IBAL#Channel_126",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#TemperatureSensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://example.org/IBAL#Segment_88"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#ts_in_rtd"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc20-OCP"
+ "@value": "Channel 126"
}
]
},
{
- "@id": "http://example.org/IBAL#exf2_on",
+ "@id": "http://example.org/IBAL#Channel_401",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Controller"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Voltage"
+ "@id": "http://example.org/IBAL#HeatingCoil_2"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "http://example.org/IBAL#vav1_heat_c"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "exf2 on"
+ "@value": "Channel 401"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_63",
+ "@id": "http://example.org/IBAL#Segment_76temp",
"@type": [
- "http://data.ashrae.org/standard223#ElectricMeter"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://example.org/IBAL#HeatingCoil_2"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://example.org/IBAL#vav1_heat_power"
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "75"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 63"
+ "@value": "Segment 76temp"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc1-ICP",
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_1_ICP_1",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://example.org/IBAL#Segment_105"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@value": "Jnc1-ICP"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#HC_2_W_ICP",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_1"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "HC 2 W ICP"
+ "@value": "Motorized three way valve 1 ICP 1"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_16",
+ "@id": "http://example.org/IBAL#zs4_out_rtd",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/bacnet/2020#AnalogInputObject",
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/bacnet/2020#description": [
{
- "@id": "http://example.org/IBAL#HVAC_Space_3_OCP"
- },
+ "@value": "Zone4 Temperature"
+ }
+ ],
+ "http://data.ashrae.org/bacnet/2020#object-identifier": [
{
- "@id": "http://example.org/IBAL#Jnc6-ICP1"
+ "@value": "analog-input,5"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/bacnet/2020#object-name": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@value": "zs4_out_rtd"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/bacnet/2020#object-type": [
{
- "@value": "Segment 16"
+ "@value": "analog-input"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#Segment_22",
- "@type": [
- "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/bacnet/2020#objectOf": [
+ {
+ "@id": "http://example.org/IBAL#HVACZone_4"
+ }
+ ],
+ "http://data.ashrae.org/bacnet/2020#present-value": [
{
- "@id": "http://example.org/IBAL#Jnc6-OCP"
- },
+ "@type": "http://www.w3.org/2001/XMLSchema#float",
+ "@value": "70.0"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://example.org/IBAL#Jnc8-ICP"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 22"
+ "@value": "zs4_out_rtd"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_52",
+ "@id": "http://example.org/IBAL#Jnc34-ICP",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://data.ashrae.org/standard223#lnx": [
- {
- "@id": "http://example.org/IBAL#AHU_3_ICP"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 52"
+ "@value": "Jnc34-ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc31-ICP1",
+ "@id": "http://example.org/IBAL#Channel_329",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Controller"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://example.org/IBAL#MotorizedDamper_13"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#d6_pos_fb"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc31-ICP1"
+ "@value": "Channel 329"
}
]
},
{
- "@id": "http://example.org/IBAL#HVAC_Space_2_OCP",
+ "@id": "http://example.org/IBAL#Segment_86",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Connection"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Segment_14"
+ "@id": "http://example.org/IBAL#Jnc27-OCP2"
+ },
+ {
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_5_ICP"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "HVAC Space2 OCP"
+ "@value": "Segment 86"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_405",
+ "@id": "http://example.org/IBAL#Segment_18",
"@type": [
- "http://data.ashrae.org/standard223#Controller"
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#HeatingCoil_1"
+ "@id": "http://example.org/IBAL#HVAC_Space_4_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc6-ICP2"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#ahu2_heat_c"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 405"
+ "@value": "Segment 18"
}
]
},
{
- "@id": "http://example.org/IBAL#vav1_heat_c",
+ "@id": "http://example.org/IBAL#vav3_heat_c",
"@type": [
- "http://data.ashrae.org/bacnet/2020#AnalogOutputObject",
+ "http://data.ashrae.org/standard223#AnalogOutputObject",
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://data.ashrae.org/bacnet/2020#description": [
{
- "@value": "VAV1 Heater Control Signal"
+ "@value": "VAV3 Heater Control Signal"
}
],
"http://data.ashrae.org/bacnet/2020#object-identifier": [
@@ -10601,7 +10425,7 @@
],
"http://data.ashrae.org/bacnet/2020#object-name": [
{
- "@value": "vav1_heat_c"
+ "@value": "vav3_heat_c"
}
],
"http://data.ashrae.org/bacnet/2020#object-type": [
@@ -10611,7 +10435,7 @@
],
"http://data.ashrae.org/bacnet/2020#objectOf": [
{
- "@id": "http://example.org/IBAL#VAV_1"
+ "@id": "http://example.org/IBAL#VAV_3"
}
],
"http://data.ashrae.org/bacnet/2020#present-value": [
@@ -10632,312 +10456,400 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "vav1 heat c"
+ "@value": "vav3 heat c"
}
]
},
{
- "@id": "http://example.org/IBAL#Hydronic",
+ "@id": "http://example.org/IBAL#Channel_397",
"@type": [
- "http://data.ashrae.org/standard223#System"
+ "http://data.ashrae.org/standard223#Controller"
],
- "http://data.ashrae.org/standard223#hasMember": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#CoolingCoil_1"
- },
+ "@id": "http://example.org/IBAL#HeatingCoil_4"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#CoolingCoil_2"
- },
+ "@id": "http://example.org/IBAL#ahu1_heat_c"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://example.org/IBAL#PlateHeatExchanger_1"
+ "@value": "Channel 397"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HeatingCoil_7",
+ "@type": [
+ "http://data.ashrae.org/standard223#HeatingCoil"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#HC_7_E_ICP"
},
{
- "@id": "http://example.org/IBAL#PlateHeatExchanger_2"
+ "@id": "http://example.org/IBAL#HC_7_ICP"
},
{
- "@id": "http://example.org/IBAL#ThermalStorage_1"
+ "@id": "http://example.org/IBAL#HC_7_OCP"
},
{
- "@id": "http://example.org/IBAL#WaterChiller_1"
+ "@id": "http://example.org/IBAL#HC_7_W_ICP"
},
{
- "@id": "http://example.org/IBAL#WaterChiller_2"
+ "@id": "http://example.org/IBAL#HC_7_W_OCP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Hydronic"
+ "@value": "Heating coil 7"
}
]
},
{
- "@id": "http://example.org/IBAL#WaterChiller_2",
+ "@id": "http://example.org/IBAL#AHU_2_S_ICP",
"@type": [
- "http://data.ashrae.org/standard223#Chiller"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#Chiller_2_Lower_ICP"
- },
+ "@id": "http://data.ashrae.org/standard223#Electricity-Signal"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://example.org/IBAL#Chiller_2_Lower_OCP"
- },
+ "@value": "AHU 2 S ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc28-OCP1",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Chiller_2_Upper_ICP"
- },
+ "@id": "http://example.org/IBAL#Segment_77"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#Chiller_2_Upper_OCP"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Water Chiller 2"
+ "@value": "Jnc28-OCP1"
}
]
},
{
- "@id": "http://example.org/IBAL#ahu1_out_rtd",
+ "@id": "http://example.org/IBAL#Segment_100",
"@type": [
- "http://data.ashrae.org/bacnet/2020#AnalogInputObject",
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/bacnet/2020#description": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@value": "AHU1 Supply Air Temperature"
+ "@id": "http://example.org/IBAL#Jnc37-OCP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc38-ICP"
}
],
- "http://data.ashrae.org/bacnet/2020#object-identifier": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@value": "analog-input,2"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
- "http://data.ashrae.org/bacnet/2020#object-name": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "ahu1_out_rtd"
+ "@value": "Segment 100"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc16-ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/bacnet/2020#object-type": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@value": "analog-input"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/bacnet/2020#objectOf": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://example.org/IBAL#AHU_2"
+ "@value": "Jnc16-ICP"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#VFD_1",
+ "@type": [
+ "http://data.ashrae.org/standard223#VariableFrequencyDrive"
],
- "http://data.ashrae.org/bacnet/2020#present-value": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@type": "http://www.w3.org/2001/XMLSchema#float",
- "@value": "70.0"
+ "@id": "http://example.org/IBAL#VFD_1_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#VFD_1_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "VFD 1"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#ch1_f_e",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_F"
+ "@id": "http://qudt.org/vocab/unit/GAL_US-PER-MIN"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "ch1 f e"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc8-OCP2",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc8-OCP2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc32-ICP2",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "AHU 1 Out RTD"
+ "@value": "Jnc32-ICP2"
}
]
},
{
- "@id": "http://example.org/IBAL#VAV_4_Connection_2",
+ "@id": "http://example.org/IBAL#Channel_124",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#TemperatureSensor"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#HVAC_Space_4_ICP"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#VAV_4_OCP"
+ "@id": "http://example.org/IBAL#Segment_105"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://example.org/IBAL#ahu1_cc_out_rtd"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "VAV 4 Connection 2"
+ "@value": "Channel 124"
}
]
},
{
- "@id": "http://example.org/IBAL#HVACZone_1",
+ "@id": "http://example.org/IBAL#WaterTempSensor_13",
"@type": [
- "http://data.ashrae.org/standard223#Zone"
+ "http://data.ashrae.org/standard223#TemperatureSensor"
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://example.org/IBAL#Segment_97"
}
],
- "http://data.ashrae.org/standard223#hasDomainSpace": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#HVACSpace_1"
+ "@id": "http://example.org/IBAL#Segment_97_Temp"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "HVACZone 1"
+ "@value": "Water Temp Sensor 13"
}
]
},
{
- "@id": "http://example.org/IBAL#ManualTwoWayValve_1_ICP",
+ "@id": "http://example.org/IBAL#Channel_364",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Controller"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://example.org/IBAL#MotorizedDamper_4"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#d18_pos_fb"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Manual two way valve 1 ICP"
+ "@value": "Channel 364"
}
]
},
{
- "@id": "http://example.org/IBAL#ThermalStorage_1_OCP",
+ "@id": "http://example.org/IBAL#Jnc24-OCP2",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-ChilledWater"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Thermal Storage 1 OCP"
+ "@value": "Jnc24-OCP2"
}
]
},
{
- "@id": "http://example.org/IBAL#Junction_33",
+ "@id": "http://example.org/IBAL#Fan_1_VFD_1",
"@type": [
- "http://data.ashrae.org/standard223#Junction"
+ "http://data.ashrae.org/standard223#Connection"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Jnc33-ICP1"
- },
- {
- "@id": "http://example.org/IBAL#Jnc33-OCP"
+ "@id": "http://example.org/IBAL#Fan_1_S_ICP"
},
{
- "@id": "http://example.org/IBAL#Jnc33-OCP2"
+ "@id": "http://example.org/IBAL#VFD_1_OCP"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://data.ashrae.org/standard223#Electricity-Signal"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Junction 33"
+ "@value": "Fan 1 to VFD 1"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc23-OCP",
+ "@id": "http://example.org/IBAL#Channel_134",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#TemperatureSensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://example.org/IBAL#HeatExchange_Connection"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#hx3_pg_rtd"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc23-OCP"
+ "@value": "Channel 129"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_425",
+ "@id": "http://example.org/IBAL#HC_3_E_ICP",
"@type": [
- "http://data.ashrae.org/standard223#Controller"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "http://example.org/IBAL#MotorizedDamper_8"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#d10_pos_c"
+ "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 425"
+ "@value": "HC 3 E ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc38-OCP",
+ "@id": "http://example.org/IBAL#Jnc8-OCP1",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#Segment_101"
- }
- ],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc38-OCP"
+ "@value": "Jnc8-OCP1"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_96",
+ "@id": "http://example.org/IBAL#Segment_16",
"@type": [
"http://data.ashrae.org/standard223#Connection"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Jnc35-OCP"
+ "@id": "http://example.org/IBAL#HVAC_Space_3_OCP"
},
{
- "@id": "http://example.org/IBAL#WaterPump_4_ICP"
+ "@id": "http://example.org/IBAL#Jnc6-ICP1"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 96"
+ "@value": "Segment 16"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc10-ICP2",
+ "@id": "http://example.org/IBAL#Segment_22",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc6-OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc8-ICP"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -10946,116 +10858,119 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc10-ICP2"
+ "@value": "Segment 22"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc38-ICP",
+ "@id": "http://example.org/IBAL#Segment_26",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Connection"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Segment_100"
+ "@id": "http://example.org/IBAL#Damper_10_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc9-OCP"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc38-ICP"
+ "@value": "Segment 26"
}
]
},
{
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_4_OCP",
+ "@id": "http://example.org/IBAL#zs1_t_sp_f",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/bacnet/2020#AnalogInputObject",
+ "http://data.ashrae.org/standard223#QuantifiableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/bacnet/2020#description": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@value": "Zone1 Temperature Setpoint"
}
],
- "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ "http://data.ashrae.org/bacnet/2020#object-identifier": [
{
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_4"
+ "@value": "analog-input,6"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/bacnet/2020#object-name": [
{
- "@value": "Motorized three way valve 4 OCP"
+ "@value": "zs1_t_sp_f"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#HC_4_ICP",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/bacnet/2020#object-type": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@value": "analog-input"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/bacnet/2020#objectOf": [
{
- "@id": "http://example.org/IBAL#AHU_2_ICP"
+ "@id": "http://example.org/IBAL#VAV_1"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/bacnet/2020#present-value": [
{
- "@value": "HC 4 ICP"
+ "@type": "http://www.w3.org/2001/XMLSchema#float",
+ "@value": "74.0"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#HC-3-OutletFlow",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasValue": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@type": "http://www.w3.org/2001/XMLSchema#decimal",
- "@value": "500"
+ "@id": "http://data.ashrae.org/standard223#Aspect-Setpoint"
}
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PA"
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
}
],
- "http://qudt.org/schema/qudt/value": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "500"
+ "@value": "zs1 t sp f"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_1_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "HC 3 OutletFlow"
+ "@value": "Damper 1 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_45",
+ "@id": "http://example.org/IBAL#Segment_36",
"@type": [
"http://data.ashrae.org/standard223#Connection"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Damper_15_ICP"
+ "@id": "http://example.org/IBAL#AHU_1_ICP"
},
{
- "@id": "http://example.org/IBAL#Jnc15-OCP1"
+ "@id": "http://example.org/IBAL#Jnc13-OCP"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -11065,523 +10980,534 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 45"
+ "@value": "Segment 36"
}
]
},
{
- "@id": "http://example.org/IBAL#Chiller_1_Lower_ICP",
+ "@id": "http://example.org/IBAL#Segment_46",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Damper_16_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc15-OCP2"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Chiller 1 Lower ICP"
+ "@value": "Segment 46"
}
]
},
{
- "@id": "http://example.org/IBAL#pl_out_rtd",
+ "@id": "http://example.org/IBAL#MotorizedDamper_13",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Damper"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "http://example.org/IBAL#Damper_13_ICP"
+ },
{
- "@id": "http://qudt.org/vocab/unit/DEG_F"
+ "@id": "http://example.org/IBAL#Damper_13_OCP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "pl out rtd"
+ "@value": "Motorized damper 13"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_62",
+ "@id": "http://example.org/IBAL#Channel_13",
"@type": [
- "http://data.ashrae.org/standard223#ElectricMeter"
+ "http://data.ashrae.org/standard223#PressureSensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#HeatingCoil_1"
+ "@id": "http://example.org/IBAL#Segment_27"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#ahu2_heat_power"
+ "@id": "http://example.org/IBAL#exf1_p_up"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 62"
+ "@value": "Channel 13"
}
]
},
{
- "@id": "http://example.org/IBAL#ahu2_on",
+ "@id": "http://example.org/IBAL#Junction_14",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Junction"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Voltage"
+ "@id": "http://example.org/IBAL#Jnc14-ICP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc14-ICP2"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc14-OCP"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "ahu2 on"
+ "@value": "Junction 14"
}
]
},
{
- "@id": "http://example.org/IBAL#Fan_2_ICP",
+ "@id": "http://example.org/IBAL#HC_2_W_ICP",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Fan 2 ICP"
+ "@value": "HC 2 W ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#vav3_t_in",
+ "@id": "http://example.org/IBAL#Channel_412",
"@type": [
- "http://data.ashrae.org/bacnet/2020#AnalogInputObject",
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Controller"
],
- "http://data.ashrae.org/bacnet/2020#description": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@value": "VAV3 Supply Air Temperature"
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_1"
}
],
- "http://data.ashrae.org/bacnet/2020#object-identifier": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@value": "analog-input,3"
+ "@id": "http://example.org/IBAL#v12_pos_c"
}
],
- "http://data.ashrae.org/bacnet/2020#object-name": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "vav3_t_in"
+ "@value": "Channel 412"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_5_VFD_5",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/bacnet/2020#object-type": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@value": "analog-input"
+ "@id": "http://example.org/IBAL#Fan_5_E_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#VFD_5_OCP"
}
],
- "http://data.ashrae.org/bacnet/2020#objectOf": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#VAV_3"
+ "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
}
],
- "http://data.ashrae.org/bacnet/2020#present-value": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@type": "http://www.w3.org/2001/XMLSchema#float",
- "@value": "70.0"
+ "@value": "Fan 5 VFD 5"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_11_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Segment_35"
}
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_F"
+ "@id": "http://example.org/IBAL#MotorizedDamper_11"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "vav3 t in"
+ "@value": "Damper 11 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc29-ICP",
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_2_ICP_1",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Segment_106"
+ }
+ ],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_2"
+ }
+ ],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc29-ICP"
+ "@value": "Motorized three way valve 2 ICP 1"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_496",
+ "@id": "http://example.org/IBAL#Junction_38",
"@type": [
- "http://data.ashrae.org/standard223#Controller"
+ "http://data.ashrae.org/standard223#Junction"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#MotorizedDamper_6"
+ "@id": "http://example.org/IBAL#Jnc38-ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc38-OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc38-OCP2"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#d11_pos_fb"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 496"
+ "@value": "Junction 38"
}
]
},
{
- "@id": "http://example.org/IBAL#ahu2_heat_power",
+ "@id": "http://example.org/IBAL#PlateHeatExchange_1_Lower_ICP",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/W"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "ahu2 heat power"
+ "@value": "Plate Heat Exchange 1 Lower ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#ahu1_in_rtd",
+ "@id": "http://example.org/IBAL#v12_pos_c",
"@type": [
+ "http://data.ashrae.org/bacnet/2020#AnalogOutputObject",
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasValue": [
- {
- "@type": "http://www.w3.org/2001/XMLSchema#decimal",
- "@value": "45"
- }
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/bacnet/2020#description": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@value": "AHU1 Cooling Coil Valve Control Signal"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/bacnet/2020#object-identifier": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_F"
+ "@value": "analog-output,2"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/bacnet/2020#object-name": [
{
- "@value": "AHU 1 In RTD"
+ "@value": "v12_pos_c"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#Jnc12-OCP2",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/bacnet/2020#object-type": [
{
- "@id": "http://example.org/IBAL#Segment_39"
+ "@value": "analog-output"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/bacnet/2020#objectOf": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://example.org/IBAL#AHU_2"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/bacnet/2020#present-value": [
{
- "@value": "Jnc12-OCP2"
+ "@type": "http://www.w3.org/2001/XMLSchema#float",
+ "@value": "0.0"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#Channel_301T",
- "@type": [
- "http://data.ashrae.org/standard223#TemperatureSensor"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://example.org/IBAL#Segment_1"
+ "@id": "http://qudt.org/vocab/quantitykind/Voltage"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://example.org/IBAL#vav1_t_in"
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 301T"
+ "@value": "v12 pos c"
}
]
},
{
- "@id": "http://example.org/IBAL#PlateHeatExchange_2_Lower_OCP",
+ "@id": "http://example.org/IBAL#Channel_454",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Controller"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://example.org/IBAL#VFD_4"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#exf2_vfd"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Plate Heat Exchange 2 Lower OCP"
+ "@value": "Channel 454"
}
]
},
{
- "@id": "http://example.org/IBAL#CC_3_W_OCP",
+ "@id": "http://example.org/IBAL#VFD_5",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#VariableFrequencyDrive"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://example.org/IBAL#VFD_5_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#VFD_5_OCP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "CC 3 W OCP"
+ "@value": "VFD 5"
}
]
},
{
- "@id": "http://example.org/IBAL#AHU2_FnB",
+ "@id": "http://example.org/IBAL#Segment_40",
"@type": [
- "http://data.ashrae.org/standard223#FunctionBlock"
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/standard223#hasInput": [
- {
- "@id": "http://example.org/IBAL#ahu1_out_rtd"
- },
- {
- "@id": "http://example.org/IBAL#ahu1_p_down"
- },
- {
- "@id": "http://example.org/IBAL#d17_pos_c"
- },
- {
- "@id": "http://example.org/IBAL#d18_pos_c"
- },
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#v12_pos_fb"
+ "@id": "http://example.org/IBAL#Damper_14_OCP"
},
{
- "@id": "http://example.org/IBAL#vav3_heat_c"
- },
+ "@id": "http://example.org/IBAL#Jnc14-ICP2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#vav4_heat_c"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#hasOutput": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://example.org/IBAL#ahu1_vfd"
- },
+ "@value": "Segment 40"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc5-OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#v12_pos_c"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "AHU2 Fn b"
+ "@value": "Jnc5-OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_303",
+ "@id": "http://example.org/IBAL#Channel_327T",
"@type": [
- "http://data.ashrae.org/standard223#FlowSensor"
+ "http://data.ashrae.org/standard223#TemperatureSensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#Segment_7"
+ "@id": "http://example.org/IBAL#Segment_39"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#vav3_f"
+ "@id": "http://example.org/IBAL#ahu2_t_sa"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 303"
+ "@value": "Channel 327T"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_65",
+ "@id": "http://example.org/IBAL#Segment_13",
"@type": [
- "http://data.ashrae.org/standard223#ElectricMeter"
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#HeatingCoil_5"
+ "@id": "http://example.org/IBAL#Jnc19-OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_2_ICP"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#vav3_heat_power"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 65"
+ "@value": "Segment 13"
}
]
},
{
- "@id": "http://example.org/IBAL#HeatingCoil_7",
+ "@id": "http://example.org/IBAL#VAV4_FnB",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil"
+ "http://data.ashrae.org/standard223#FunctionBlock"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/standard223#hasInput": [
{
- "@id": "http://example.org/IBAL#HC_7_E_ICP"
+ "@id": "http://example.org/IBAL#d18_pos_fb"
},
{
- "@id": "http://example.org/IBAL#HC_7_ICP"
+ "@id": "http://example.org/IBAL#vav4_f"
},
{
- "@id": "http://example.org/IBAL#HC_7_OCP"
+ "@id": "http://example.org/IBAL#vav4_out_rtd"
},
{
- "@id": "http://example.org/IBAL#HC_7_W_ICP"
+ "@id": "http://example.org/IBAL#vav4_t_in"
},
{
- "@id": "http://example.org/IBAL#HC_7_W_OCP"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "Heating coil 7"
- }
- ]
- },
- {
- "@id": "http://example.org/IBAL#Jnc8-OCP2",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "http://example.org/IBAL#zs4_out_rtd"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://example.org/IBAL#zs4_t_sp_f"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasOutput": [
{
- "@value": "Jnc8-OCP2"
- }
- ]
- },
- {
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_4_ICP_2",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "http://example.org/IBAL#d18_pos_c"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://example.org/IBAL#vav4_heat_c"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Motorized three way valve 4 ICP 2"
+ "@value": "VAV4 Fn b"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_72",
+ "@id": "http://example.org/IBAL#oau_hs_rtd",
"@type": [
- "http://data.ashrae.org/standard223#ElectricMeter"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasValue": [
{
- "@id": "http://example.org/IBAL#VFD_4"
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "60"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://example.org/IBAL#exf2_power"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@value": "Channel 72"
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#HC_4_W_ICP",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/value": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@value": "60"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "HC 4 W ICP"
+ "@value": "oau hs rt"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_88",
+ "@id": "http://example.org/IBAL#Segment_61",
"@type": [
- "http://data.ashrae.org/standard223#TemperatureSensor"
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#VAV_2_Connection_2"
+ "@id": "http://example.org/IBAL#Jnc20-OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc21-ICP1"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#vav2_out_rtd"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 88"
+ "@value": "Segment 61"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc33-OCP2",
+ "@id": "http://example.org/IBAL#PlateHeatExchange_2_Lower_ICP",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -11590,235 +11516,216 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc33-OCP2"
+ "@value": "Plate Heat Exchange 2 Lower ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#HC_7_W_ICP",
+ "@id": "http://example.org/IBAL#Jnc18-ICP",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "HC 7 W ICP"
+ "@value": "Jnc18-ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#v12_pos_fb",
+ "@id": "http://example.org/IBAL#Segment_105",
"@type": [
- "http://data.ashrae.org/bacnet/2020#AnalogInputObject",
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/bacnet/2020#description": [
- {
- "@value": "AHU1 Cooling Coil Feedback Signal"
- }
- ],
- "http://data.ashrae.org/bacnet/2020#object-identifier": [
- {
- "@value": "analog-input,2"
- }
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/bacnet/2020#object-name": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@value": "v12_pos_fb"
- }
- ],
- "http://data.ashrae.org/bacnet/2020#object-type": [
+ "@id": "http://example.org/IBAL#AHU_1_G_OCP"
+ },
{
- "@value": "analog-input"
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_1_ICP_1"
}
],
- "http://data.ashrae.org/bacnet/2020#objectOf": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#AHU_2"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
- "http://data.ashrae.org/bacnet/2020#present-value": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@type": "http://www.w3.org/2001/XMLSchema#float",
- "@value": "0.0"
+ "@value": "Segment 105"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Channel_61",
+ "@type": [
+ "http://data.ashrae.org/standard223#ElectricMeter"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Voltage"
+ "@id": "http://example.org/IBAL#HeatingCoil_4"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "http://example.org/IBAL#ahu1_heat_power"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "v12 pos fb"
+ "@value": "Channel 61"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_121",
+ "@id": "http://example.org/IBAL#Channel_325T",
"@type": [
"http://data.ashrae.org/standard223#TemperatureSensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#Segment_76"
+ "@id": "http://example.org/IBAL#Segment_23"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#ch1_e_in_rtd"
+ "@id": "http://example.org/IBAL#ahu1_t_ra"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 121"
+ "@value": "Channel 325T"
}
]
},
{
- "@id": "http://example.org/IBAL#Fan_5_E_ICP",
+ "@id": "http://example.org/IBAL#MotorizedDamper_3",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Damper"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
+ "@id": "http://example.org/IBAL#Damper_3_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_3_OCP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Fan 5 E ICP"
+ "@value": "Motorized damper 3"
}
]
},
{
- "@id": "http://example.org/IBAL#HeatExchange",
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_2",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#TwoWayValve"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_F"
- }
- ],
- "http://qudt.org/schema/qudt/value": [
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_2_ICP"
+ },
{
- "@value": "60"
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_2_OCP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "HeatExchange"
+ "@value": "Manual two way valve 2"
}
]
},
{
- "@id": "http://example.org/IBAL#ahu2_in_rtd",
+ "@id": "http://example.org/IBAL#Channel_326T",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#TemperatureSensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://example.org/IBAL#Segment_38"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_F"
+ "@id": "http://example.org/IBAL#ahu1_t_sa"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "ahu2 in rtd"
+ "@value": "Channel 326T"
}
]
},
{
- "@id": "http://example.org/IBAL#ahu2_t_sa",
+ "@id": "http://example.org/IBAL#Channel_10",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#HumiditySensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://example.org/IBAL#Segment_1"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_F"
+ "@id": "http://example.org/IBAL#ahu2_rh_down"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "ahu 2 t sa"
+ "@value": "Channel 10"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_302",
+ "@id": "http://example.org/IBAL#Channel_106",
"@type": [
- "http://data.ashrae.org/standard223#FlowSensor"
+ "http://data.ashrae.org/standard223#TemperatureSensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#Segment_4"
+ "@id": "http://example.org/IBAL#Segment_12"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#vav2_f"
+ "@id": "http://example.org/IBAL#zs1_out_rtd"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 302"
+ "@value": "Channel 106"
}
]
},
{
- "@id": "http://example.org/IBAL#HeatingCoil_5",
+ "@id": "http://example.org/IBAL#Channel_65",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil"
+ "http://data.ashrae.org/standard223#ElectricMeter"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "http://example.org/IBAL#HC_5_E_ICP"
- },
- {
- "@id": "http://example.org/IBAL#HC_5_ICP"
- },
- {
- "@id": "http://example.org/IBAL#HC_5_OCP"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#HC_5_W_ICP"
- },
+ "@id": "http://example.org/IBAL#HeatingCoil_5"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#HC_5_W_OCP"
+ "@id": "http://example.org/IBAL#vav3_heat_power"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Heating coil 5"
+ "@value": "Channel 65"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_76temp",
+ "@id": "http://example.org/IBAL#oau_in_rtd",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -11832,46 +11739,51 @@
"@id": "http://qudt.org/vocab/unit/DEG_F"
}
],
- "http://qudt.org/schema/qudt/value": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "75"
+ "@value": "oau in rtd"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#VAV_4_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 76temp"
+ "@value": "VAV 4 ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#Junction_28",
+ "@id": "http://example.org/IBAL#HVAC_Space_1_OCP",
"@type": [
- "http://data.ashrae.org/standard223#Junction"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Jnc28-ICP"
- },
- {
- "@id": "http://example.org/IBAL#Jnc28-OCP1"
- },
- {
- "@id": "http://example.org/IBAL#Jnc28-OCP2"
+ "@id": "http://example.org/IBAL#Segment_12"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Junction 28"
+ "@value": "HVAC Space1 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#AHU_2_OCP",
+ "@id": "http://example.org/IBAL#Jnc1-OCP1",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -11882,144 +11794,124 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "AHU 2 OCP"
+ "@value": "Jnc1-OCP1"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_64",
+ "@id": "http://example.org/IBAL#Fan_5_E_ICP",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#Jnc22-OCP2"
- },
- {
- "@id": "http://example.org/IBAL#ManualTwoWayValve_3_ICP"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 64"
+ "@value": "Fan 5 E ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#HVACSpace_3",
+ "@id": "http://example.org/IBAL#Channel_79",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "http://example.org/IBAL#HVAC_Space_3_ICP"
- },
- {
- "@id": "http://example.org/IBAL#HVAC_Space_3_OCP"
- }
+ "http://data.ashrae.org/standard223#TemperatureSensor"
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://example.org/IBAL#AHU_1_Connection_3"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#zs3_t_sp_f"
+ "@id": "http://example.org/IBAL#ahu2_cc_rtd"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "HVACSpace 3"
+ "@value": "Channel 79"
}
]
},
{
- "@id": "http://example.org/IBAL#WaterChiller_1",
+ "@id": "http://example.org/IBAL#Damper_7_ICP",
"@type": [
- "http://data.ashrae.org/standard223#Chiller"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "http://example.org/IBAL#Chiller_1_Lower_ICP"
- },
- {
- "@id": "http://example.org/IBAL#Chiller_1_Lower_OCP"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#Chiller_1_Upper_ICP"
- },
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
{
- "@id": "http://example.org/IBAL#Chiller_1_Upper_OCP"
+ "@id": "http://example.org/IBAL#MotorizedDamper_7"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Water Chiller 1"
+ "@value": "Damper 7 ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_381",
+ "@id": "http://example.org/IBAL#Channel_336AO",
"@type": [
"http://data.ashrae.org/standard223#Controller"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_5"
+ "@id": "http://example.org/IBAL#VAV_1"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#v8_pos_c"
+ "@id": "http://example.org/IBAL#d15_pos_c"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 381"
+ "@value": "Channel 336AO"
}
]
},
{
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_5_ICP_1",
+ "@id": "http://example.org/IBAL#Channel_334T",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#TemperatureSensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://example.org/IBAL#Segment_20"
}
],
- "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_5"
+ "@id": "http://example.org/IBAL#ahu2_t_ra"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Motorized three way valve 5 ICP 1"
+ "@value": "Channel 334T"
}
]
},
{
- "@id": "http://example.org/IBAL#Junction_19",
+ "@id": "http://example.org/IBAL#Junction_34",
"@type": [
"http://data.ashrae.org/standard223#Junction"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Jnc19-ICP"
+ "@id": "http://example.org/IBAL#Jnc34-ICP"
},
{
- "@id": "http://example.org/IBAL#Jnc19-OCP"
+ "@id": "http://example.org/IBAL#Jnc34-OCP1"
},
{
- "@id": "http://example.org/IBAL#Jnc19-OCP2"
+ "@id": "http://example.org/IBAL#Jnc34-OCP2"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -12029,371 +11921,355 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Junction 19"
+ "@value": "Junction 34"
}
]
},
{
- "@id": "http://example.org/IBAL#ahu1_heat_c",
+ "@id": "http://example.org/IBAL#VFD_4",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#VariableFrequencyDrive"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Voltage"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "http://example.org/IBAL#VFD_4_ICP"
+ },
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "http://example.org/IBAL#VFD_4_OCP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "AHU1 Heat C"
+ "@value": "VFD 4"
}
]
},
{
- "@id": "http://example.org/IBAL#vav2_f",
+ "@id": "http://example.org/IBAL#HVACSpace_2",
"@type": [
- "http://data.ashrae.org/bacnet/2020#AnalogInputObject",
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/bacnet/2020#description": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@value": "VAV2 Airflow Rate"
+ "@id": "http://example.org/IBAL#HVAC_Space_2_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HVAC_Space_2_OCP"
}
],
- "http://data.ashrae.org/bacnet/2020#object-identifier": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@value": "analog-input,4"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
],
- "http://data.ashrae.org/bacnet/2020#object-name": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@value": "vav2_f"
+ "@id": "http://example.org/IBAL#zs2_t_sp_f"
}
],
- "http://data.ashrae.org/bacnet/2020#object-type": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "analog-input"
+ "@value": "HVACSpace 2"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Channel_451",
+ "@type": [
+ "http://data.ashrae.org/standard223#Controller"
],
- "http://data.ashrae.org/bacnet/2020#objectOf": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#VAV_2"
+ "@id": "http://example.org/IBAL#VFD_1"
}
],
- "http://data.ashrae.org/bacnet/2020#present-value": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@type": "http://www.w3.org/2001/XMLSchema#float",
- "@value": "0.0"
+ "@id": "http://example.org/IBAL#ahu2_vfd"
}
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@value": "Channel 451"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#zs2_out_rtd",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/bacnet/2020#description": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@value": "Zone2 Temperature"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/bacnet/2020#object-identifier": [
{
- "@value": "vav2 f"
+ "@value": "analog-input,5"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#d8_pos_fb",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/bacnet/2020#object-name": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositionVector"
+ "@value": "Zone2 Temperature"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/bacnet/2020#object-type": [
{
- "@value": "d8 pos fb"
+ "@value": "analog-input"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#ManualTwoWayValve_4_ICP",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/bacnet/2020#objectOf": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://example.org/IBAL#VAV_2"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/bacnet/2020#present-value": [
{
- "@value": "Manual two way valve 4 ICP"
+ "@type": "http://www.w3.org/2001/XMLSchema#float",
+ "@value": "70.0"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#ahu2_f_sa",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "ahu2 f sa"
+ "@value": "zs2 out rtd"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc6-OCP",
+ "@id": "http://example.org/IBAL#Channel_8",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#PressureSensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#Segment_22"
+ "@id": "http://example.org/IBAL#AHU_1_Connection_3"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://example.org/IBAL#ahu2_p_up"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc6-OCP"
+ "@value": "Channel 8"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_28",
+ "@id": "http://example.org/IBAL#Junction_29",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#Junction"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Damper_8_OCP"
+ "@id": "http://example.org/IBAL#Jnc29-ICP"
},
{
- "@id": "http://example.org/IBAL#Jnc10-ICP1"
+ "@id": "http://example.org/IBAL#Jnc29-OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc29-OCP2"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 28"
+ "@value": "Junction 29"
}
]
},
{
- "@id": "http://example.org/IBAL#Junction_10",
+ "@id": "http://example.org/IBAL#Channel_84",
"@type": [
- "http://data.ashrae.org/standard223#Junction"
+ "http://data.ashrae.org/standard223#TemperatureSensor"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#Jnc10-ICP1"
- },
- {
- "@id": "http://example.org/IBAL#Jnc10-ICP2"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#Jnc10-OCP"
+ "@id": "http://example.org/IBAL#AHU_3_Connection_2"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://example.org/IBAL#oau_cc_rtd"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Junction 10"
+ "@value": "Channel 84"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc38-OCP2",
+ "@id": "http://example.org/IBAL#WaterPump_1",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Pump"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://example.org/IBAL#WaterPump_1_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#WaterPump_1_OCP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc38-OCP2"
+ "@value": "Water pump 1"
}
]
},
{
- "@id": "http://example.org/IBAL#AHU_1_S_ICP",
+ "@id": "http://example.org/IBAL#Fan_5_ICP",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Electricity-Signal"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "AHU 1 S ICP"
+ "@value": "Fan 5 ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#exf2_p_down",
+ "@id": "http://example.org/IBAL#hx3_pg_rtd",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PA"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "exf2 p down"
- }
- ]
- },
- {
- "@id": "http://example.org/IBAL#Channel_76",
- "@type": [
- "http://data.ashrae.org/standard223#TemperatureSensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "http://example.org/IBAL#Segment_9"
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/value": [
{
- "@id": "http://example.org/IBAL#ahu1_out_rtd"
+ "@value": "72"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 76"
+ "@value": "hx1 pg rtd"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_70",
+ "@id": "http://example.org/IBAL#HVACSpace_3",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://example.org/IBAL#Jnc25-OCP1"
+ "@id": "http://example.org/IBAL#HVAC_Space_3_ICP"
},
{
- "@id": "http://example.org/IBAL#PlateHeatExchange_2_Lower_ICP"
+ "@id": "http://example.org/IBAL#HVAC_Space_3_OCP"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "http://example.org/IBAL#zs3_t_sp_f"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 70"
+ "@value": "HVACSpace 3"
}
]
},
{
- "@id": "http://example.org/IBAL#vav3_f",
+ "@id": "http://example.org/IBAL#VAV_4",
"@type": [
- "http://data.ashrae.org/bacnet/2020#AnalogInputObject",
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/bacnet/2020#BACnetDevice",
+ "http://data.ashrae.org/standard223#TerminalUnit"
],
- "http://data.ashrae.org/bacnet/2020#description": [
+ "http://data.ashrae.org/bacnet/2020#hasPort": [
{
- "@value": "VAV3 Airflow Rate"
+ "@id": "http://data.ashrae.org/bacnet/2020#P_47814"
}
],
- "http://data.ashrae.org/bacnet/2020#object-identifier": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@value": "analog-input,4"
- }
- ],
- "http://data.ashrae.org/bacnet/2020#object-name": [
+ "@id": "http://example.org/IBAL#HeatingCoil_6"
+ },
{
- "@value": "vav3_f"
+ "@id": "http://example.org/IBAL#MotorizedDamper_4"
}
],
- "http://data.ashrae.org/bacnet/2020#object-type": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@value": "analog-input"
- }
- ],
- "http://data.ashrae.org/bacnet/2020#objectOf": [
+ "@id": "http://example.org/IBAL#VAV_4_ICP"
+ },
{
- "@id": "http://example.org/IBAL#VAV_3"
+ "@id": "http://example.org/IBAL#VAV_4_OCP"
}
],
- "http://data.ashrae.org/bacnet/2020#present-value": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@type": "http://www.w3.org/2001/XMLSchema#float",
- "@value": "0.0"
+ "@value": "VAV 4"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Channel_306T",
+ "@type": [
+ "http://data.ashrae.org/standard223#TemperatureSensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://example.org/IBAL#Segment_27"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://example.org/IBAL#exf1_t_in"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "vav3 f"
+ "@value": "Channel 306T"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_40",
+ "@id": "http://example.org/IBAL#Segment_19",
"@type": [
"http://data.ashrae.org/standard223#Connection"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Damper_14_OCP"
+ "@id": "http://example.org/IBAL#Jnc5-OCP"
},
{
- "@id": "http://example.org/IBAL#Jnc14-ICP2"
+ "@id": "http://example.org/IBAL#Jnc7-ICP"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -12403,55 +12279,45 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 40"
- }
- ]
- },
- {
- "@id": "http://example.org/IBAL#Enclosure_1",
- "@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
- ],
- "http://data.ashrae.org/standard223#encloses": [
- {
- "@id": "http://example.org/IBAL#HVACSpace_1"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "Enclosure 1"
+ "@value": "Segment 19"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_394bw",
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_5_ICP_1",
"@type": [
- "http://data.ashrae.org/standard223#Controller"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#Fan_4"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
{
- "@id": "http://example.org/IBAL#exf2_on"
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_5"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 394bw"
+ "@value": "Motorized three way valve 5 ICP 1"
}
]
},
{
- "@id": "http://example.org/IBAL#AHU_3_ICP",
+ "@id": "http://example.org/IBAL#Junction_11",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Junction"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Segment_52"
+ "@id": "http://example.org/IBAL#Jnc11-ICP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc11-ICP2"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc11-OCP"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -12461,14 +12327,14 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "AHU 3 ICP"
+ "@value": "Junction 11"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc3-ICP2",
+ "@id": "http://example.org/IBAL#Jnc16-OCP1",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -12477,84 +12343,85 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc3-ICP2"
+ "@value": "Jnc16-OCP1"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_97_Temp",
+ "@id": "http://example.org/IBAL#Segment_49",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "http://example.org/IBAL#Damper_18_ICP"
+ },
{
- "@id": "http://qudt.org/vocab/unit/DEG_F"
+ "@id": "http://example.org/IBAL#Jnc16-OCP2"
}
],
- "http://qudt.org/schema/qudt/value": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@value": "60"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment_97_Temp"
+ "@value": "Segment 49"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc33-ICP2",
+ "@id": "http://example.org/IBAL#Channel_89",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#TemperatureSensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://example.org/IBAL#VAV_3_Connection_2"
}
],
- "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#Junction_33"
+ "@id": "http://example.org/IBAL#vav3_out_rtd"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc33-ICP2"
+ "@value": "Channel 89"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc29-OCP2",
+ "@id": "http://example.org/IBAL#Fan_3_E_ICP",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc29-OCP2"
+ "@value": "Fan 3 E ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_103",
+ "@id": "http://example.org/IBAL#Junction_32",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#Junction"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#AHU_1_G_ICP"
+ "@id": "http://example.org/IBAL#Jnc32-ICP1"
},
{
- "@id": "http://example.org/IBAL#Jnc19-OCP2"
+ "@id": "http://example.org/IBAL#Jnc32-ICP2"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc32-OCP"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -12564,147 +12431,178 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 103"
+ "@value": "Junction 32"
}
]
},
{
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_3_ICP_2",
+ "@id": "http://example.org/IBAL#Damper_19_OCP",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://data.ashrae.org/standard223#isConnectionPointOf": [
{
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_3"
+ "@id": "http://example.org/IBAL#MotorizedDamper_19"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Motorized three way valve 3 ICP 2"
+ "@value": "Damper 19 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#VFD_1_OCP",
+ "@id": "http://example.org/IBAL#Fan_3_ICP",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Electricity-Signal"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "VFD 1 OCP"
+ "@value": "Fan 3 ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc13-ICP2",
+ "@id": "http://example.org/IBAL#vav4_heat_c",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/bacnet/2020#AnalogOutputObject",
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/bacnet/2020#description": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@value": "VAV4 Heater Control Signal"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/bacnet/2020#object-identifier": [
{
- "@value": "Jnc13-ICP2"
+ "@value": "analog-output,1"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#Temp_7",
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ ],
+ "http://data.ashrae.org/bacnet/2020#object-name": [
{
- "@value": "Channel 106"
+ "@value": "vav4_heat_c"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#Junction_12",
- "@type": [
- "http://data.ashrae.org/standard223#Junction"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/bacnet/2020#object-type": [
{
- "@id": "http://example.org/IBAL#Jnc12-ICP"
- },
+ "@value": "analog-output"
+ }
+ ],
+ "http://data.ashrae.org/bacnet/2020#objectOf": [
{
- "@id": "http://example.org/IBAL#Jnc12-OCP1"
- },
+ "@id": "http://example.org/IBAL#VAV_4"
+ }
+ ],
+ "http://data.ashrae.org/bacnet/2020#present-value": [
{
- "@id": "http://example.org/IBAL#Jnc12-OCP2"
+ "@type": "http://www.w3.org/2001/XMLSchema#float",
+ "@value": "0.0"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Voltage"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Junction 12"
+ "@value": "vav4 heat c"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc19-OCP2",
+ "@id": "http://example.org/IBAL#Channel_201",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Controller"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://example.org/IBAL#MotorizedDamper_2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#d16_pos_c"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc19-OCP2"
+ "@value": "Channel 201"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_79",
+ "@id": "http://example.org/IBAL#Segment_97_Temp",
"@type": [
- "http://data.ashrae.org/standard223#TemperatureSensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://example.org/IBAL#AHU_1_Connection_3"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://example.org/IBAL#ahu2_cc_rtd"
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "60"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 79"
+ "@value": "Segment_97_Temp"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_36",
+ "@id": "http://example.org/IBAL#Junction_36",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#Junction"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#AHU_1_ICP"
+ "@id": "http://example.org/IBAL#Jnc36-ICP"
},
{
- "@id": "http://example.org/IBAL#Jnc13-OCP"
+ "@id": "http://example.org/IBAL#Jnc36-OCP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc36-OCP2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Junction 36"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc12-OCP1",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -12713,352 +12611,345 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 36"
+ "@value": "Jnc12-OCP1"
}
]
},
{
- "@id": "http://example.org/IBAL#pl_in_rtd",
+ "@id": "http://example.org/IBAL#v12_pos_fb",
"@type": [
+ "http://data.ashrae.org/bacnet/2020#AnalogInputObject",
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/bacnet/2020#description": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@value": "AHU1 Cooling Coil Feedback Signal"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/bacnet/2020#object-identifier": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_F"
+ "@value": "analog-input,2"
}
],
- "http://qudt.org/schema/qudt/value": [
+ "http://data.ashrae.org/bacnet/2020#object-name": [
{
- "@value": "68"
+ "@value": "v12_pos_fb"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/bacnet/2020#object-type": [
{
- "@value": "pl in rtd"
+ "@value": "analog-input"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#Channel_90",
- "@type": [
- "http://data.ashrae.org/standard223#TemperatureSensor"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/bacnet/2020#objectOf": [
{
- "@id": "http://example.org/IBAL#VAV_4_Connection_2"
+ "@id": "http://example.org/IBAL#AHU_2"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/bacnet/2020#present-value": [
{
- "@id": "http://example.org/IBAL#vav4_out_rtd"
+ "@type": "http://www.w3.org/2001/XMLSchema#float",
+ "@value": "0.0"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Voltage"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 90"
+ "@value": "v12 pos fb"
}
]
},
{
- "@id": "http://example.org/IBAL#AHU_2_Zone",
+ "@id": "http://example.org/IBAL#Channel_198",
"@type": [
- "http://data.ashrae.org/standard223#Zone"
+ "http://data.ashrae.org/standard223#FlowSensor"
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://example.org/IBAL#Segment_106"
}
],
- "http://data.ashrae.org/standard223#hasDomainSpace": [
- {
- "@id": "http://example.org/IBAL#HVACSpace_3"
- },
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#HVACSpace_4"
+ "@id": "http://example.org/IBAL#ahu2_f_cc_mag"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "AHU 2 Zone"
+ "@value": "Channel 198"
}
]
},
{
- "@id": "http://example.org/IBAL#hx3_pg_rtd",
+ "@id": "http://example.org/IBAL#Segment_38",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "http://example.org/IBAL#Damper_13_ICP"
+ },
{
- "@id": "http://qudt.org/vocab/unit/DEG_F"
+ "@id": "http://example.org/IBAL#Jnc12-OCP1"
}
],
- "http://qudt.org/schema/qudt/value": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@value": "72"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "hx1 pg rtd"
+ "@value": "Segment 38"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_383",
+ "@id": "http://example.org/IBAL#Jnc12-OCP2",
"@type": [
- "http://data.ashrae.org/standard223#Controller"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_1"
+ "@id": "http://example.org/IBAL#Segment_39"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#v12_pos_fb"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 383"
+ "@value": "Jnc12-OCP2"
}
]
},
{
- "@id": "http://example.org/IBAL#AHU_2",
+ "@id": "http://example.org/IBAL#Segment_41",
"@type": [
- "http://data.ashrae.org/standard223#AirHandlingUnit"
- ],
- "http://data.ashrae.org/bacnet/2020#hasPort": [
- {
- "@id": "http://data.ashrae.org/bacnet/2020#P_47815"
- }
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "http://example.org/IBAL#CoolingCoil_2"
- },
- {
- "@id": "http://example.org/IBAL#Fan_2"
- },
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#HeatingCoil_4"
+ "@id": "http://example.org/IBAL#Damper_13_OCP"
},
{
- "@id": "http://example.org/IBAL#VFD_2"
+ "@id": "http://example.org/IBAL#Jnc14-ICP1"
}
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "http://example.org/IBAL#AHU_2_G_ICP"
- },
- {
- "@id": "http://example.org/IBAL#AHU_2_G_OCP"
- },
- {
- "@id": "http://example.org/IBAL#AHU_2_ICP"
- },
- {
- "@id": "http://example.org/IBAL#AHU_2_OCP"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#AHU_2_S_ICP"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "AHU 2"
+ "@value": "Segment 41"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_16",
+ "@id": "http://example.org/IBAL#CC_3_OCP",
"@type": [
- "http://data.ashrae.org/standard223#PressureSensor"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Segment_30"
+ "@id": "http://example.org/IBAL#AHU_3_Connection_2"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#exf2_p_up"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#CoolingCoil_3"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 16"
+ "@value": " CC 3 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#PlateHeatExchanger_1",
+ "@id": "http://example.org/IBAL#Junction_8",
"@type": [
- "http://data.ashrae.org/standard223#HeatExchanger"
+ "http://data.ashrae.org/standard223#Junction"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#PlateHeatExchange_1_Lower_ICP"
+ "@id": "http://example.org/IBAL#Jnc8-ICP"
},
{
- "@id": "http://example.org/IBAL#PlateHeatExchange_1_Lower_OCP"
+ "@id": "http://example.org/IBAL#Jnc8-OCP1"
},
{
- "@id": "http://example.org/IBAL#PlateHeatExchange_1_Upper_ICP"
- },
+ "@id": "http://example.org/IBAL#Jnc8-OCP2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#PlateHeatExchange_1_Upper_OCP"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Plate heat exchanger 1"
+ "@value": "Junction 8"
}
]
},
{
- "@id": "http://example.org/IBAL#MotorizedDamper_14",
+ "@id": "http://example.org/IBAL#Jnc30-ICP2",
"@type": [
- "http://data.ashrae.org/standard223#Damper"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "http://example.org/IBAL#Damper_14_ICP"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#Damper_14_OCP"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Motorized damper 14"
+ "@value": "Jnc30-ICP2"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc24-ICP",
+ "@id": "http://example.org/IBAL#Segment_12",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Connection"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Segment_67"
+ "@id": "http://example.org/IBAL#HVAC_Space_1_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc5-ICP1"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc24-ICP"
+ "@value": "Segment 12"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_201",
+ "@id": "http://example.org/IBAL#Damper_12_OCP",
"@type": [
- "http://data.ashrae.org/standard223#Controller"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#MotorizedDamper_2"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
{
- "@id": "http://example.org/IBAL#d16_pos_c"
+ "@id": "http://example.org/IBAL#MotorizedDamper_12"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 201"
+ "@value": "Damper 12 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_200",
+ "@id": "http://example.org/IBAL#ahu2_cc_in_rtd",
"@type": [
- "http://data.ashrae.org/standard223#FlowSensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://example.org/IBAL#Segment_69"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://example.org/IBAL#pl_f"
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 200"
+ "@value": "ahu2 cc in rtd"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_66",
+ "@id": "http://example.org/IBAL#ch1_e_out_rtd",
"@type": [
- "http://data.ashrae.org/standard223#ElectricMeter"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://example.org/IBAL#HeatingCoil_6"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://example.org/IBAL#vav4_heat_power"
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 66"
+ "@value": "ch1 e out rtd"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc14-ICP1",
+ "@id": "http://example.org/IBAL#Jnc29-ICP",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc14-ICP1"
+ "@value": "Jnc29-ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_50",
+ "@id": "http://example.org/IBAL#d6_pos_fb",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://example.org/IBAL#Damper_18_OCP"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/PositionVector"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://example.org/IBAL#Jnc17-ICP2"
+ "@value": "d6 pos fb"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_1_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -13067,65 +12958,91 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 50"
+ "@value": "Fan 1 ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc27-OCP2",
+ "@id": "http://example.org/IBAL#HC_5_ICP",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc27-OCP2"
+ "@value": "HC 5 ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc25-OCP1",
+ "@id": "http://example.org/IBAL#Channel_301",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#FlowSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#Segment_2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#vav1_f"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Channel 301"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Channel_50",
+ "@type": [
+ "http://data.ashrae.org/standard223#PressureSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#Segment_44"
+ }
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://example.org/IBAL#oau_p_down"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc25-OCP1"
+ "@value": "Channel 50"
}
]
},
{
- "@id": "http://example.org/IBAL#ahu2_heat_rtd",
+ "@id": "http://example.org/IBAL#Jnc26-OCP",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://example.org/IBAL#Segment_76"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_F"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "ahu2 heat rtd"
+ "@value": "Jnc26-OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc17-ICP2",
+ "@id": "http://example.org/IBAL#Jnc13-ICP2",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -13136,692 +13053,684 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc17-ICP2"
+ "@value": "Jnc13-ICP2"
}
]
},
{
- "@id": "http://example.org/IBAL#Fan_3",
+ "@id": "http://example.org/IBAL#Segment_7",
"@type": [
- "http://data.ashrae.org/standard223#Fan"
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Fan_3_E_ICP"
+ "@id": "http://example.org/IBAL#Jnc3-OCP"
},
{
- "@id": "http://example.org/IBAL#Fan_3_ICP"
- },
+ "@id": "http://example.org/IBAL#VAV_3_ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#Fan_3_OCP"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Fan 3"
+ "@value": "Segment 7"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_9",
+ "@id": "http://example.org/IBAL#CC_2_ICP",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#AHU_2_OCP"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#Jnc4-ICP"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://example.org/IBAL#CoolingCoil_2"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 9"
+ "@value": "CC 2 ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#zs3_t_sp_f",
+ "@id": "http://example.org/IBAL#HVACZone_2",
"@type": [
- "http://data.ashrae.org/bacnet/2020#AnalogInputObject",
- "http://data.ashrae.org/standard223#QuantifiableProperty"
+ "http://data.ashrae.org/standard223#Zone"
],
- "http://data.ashrae.org/bacnet/2020#description": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@value": "Zone3 Temperature Setpoint"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
],
- "http://data.ashrae.org/bacnet/2020#object-identifier": [
+ "http://data.ashrae.org/standard223#hasDomainSpace": [
{
- "@value": "analog-input,6"
+ "@id": "http://example.org/IBAL#HVACSpace_2"
}
],
- "http://data.ashrae.org/bacnet/2020#object-name": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "zs3_t_sp_f"
+ "@value": "HVACZone 2"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Channel_425",
+ "@type": [
+ "http://data.ashrae.org/standard223#Controller"
],
- "http://data.ashrae.org/bacnet/2020#object-type": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@value": "analog-input"
+ "@id": "http://example.org/IBAL#MotorizedDamper_8"
}
],
- "http://data.ashrae.org/bacnet/2020#objectOf": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#VAV_3"
+ "@id": "http://example.org/IBAL#d10_pos_c"
}
],
- "http://data.ashrae.org/bacnet/2020#present-value": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@type": "http://www.w3.org/2001/XMLSchema#float",
- "@value": "74.0"
+ "@value": "Channel 425"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc3-OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Aspect-Setpoint"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@value": "Jnc3-OCP"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc10-ICP1",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_F"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "zs3 t sp f"
+ "@value": "Jnc10-ICP1"
}
]
},
{
- "@id": "http://example.org/IBAL#oau_p_up",
+ "@id": "http://example.org/IBAL#ahu1_heat_power",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasValue": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@type": "http://www.w3.org/2001/XMLSchema#decimal",
- "@value": "11297"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
}
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ "@id": "http://qudt.org/vocab/unit/W"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://qudt.org/vocab/unit/PA"
+ "@value": "AHU1 Heat Power"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_4_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/value": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@value": "11297"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "http://example.org/IBAL#AHU_2_ICP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "oau p up"
+ "@value": "HC 4 ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_456",
+ "@id": "http://example.org/IBAL#Channel_303T",
"@type": [
- "http://data.ashrae.org/standard223#Controller"
+ "http://data.ashrae.org/standard223#TemperatureSensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_5"
+ "@id": "http://example.org/IBAL#Segment_7"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#v8_pos_c"
+ "@id": "http://example.org/IBAL#vav3_t_in"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 456"
+ "@value": "Channel 303T"
}
]
},
{
- "@id": "http://example.org/IBAL#ahu2_p_down",
+ "@id": "http://example.org/IBAL#Channel_360",
"@type": [
- "http://data.ashrae.org/bacnet/2020#AnalogInputObject",
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/bacnet/2020#description": [
- {
- "@value": "Static Pressure Measurement Downstream Fan"
- }
+ "http://data.ashrae.org/standard223#Controller"
],
- "http://data.ashrae.org/bacnet/2020#object-identifier": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@value": "analog-input,3"
+ "@id": "http://example.org/IBAL#MotorizedDamper_2"
}
],
- "http://data.ashrae.org/bacnet/2020#object-name": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@value": "ahu2_p_down"
+ "@id": "http://example.org/IBAL#d16_pos_fb"
}
],
- "http://data.ashrae.org/bacnet/2020#object-type": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "analog-input"
+ "@value": "Channel 360"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_4_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/bacnet/2020#objectOf": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#AHU_1"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://data.ashrae.org/bacnet/2020#present-value": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@type": "http://www.w3.org/2001/XMLSchema#float",
- "@value": "0.0"
+ "@value": "Manual two way valve 4 ICP"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#exf2_power",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PA"
+ "@id": "http://qudt.org/vocab/unit/W"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "ahu2 p down"
+ "@value": "exf2 power"
}
]
},
{
- "@id": "http://example.org/IBAL#HC_7_E_ICP",
+ "@id": "http://example.org/IBAL#Jnc13-ICP1",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "HC 7 E ICP"
+ "@value": "Jnc13-ICP1"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc37-ICP",
+ "@id": "http://example.org/IBAL#Fan_4",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Fan"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://example.org/IBAL#Segment_99"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "http://example.org/IBAL#Fan_4_E_ICP"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://example.org/IBAL#Fan_4_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_4_OCP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc37-ICP"
+ "@value": "Fan 4"
}
]
},
{
- "@id": "http://example.org/IBAL#Junction_4",
+ "@id": "http://example.org/IBAL#ahu2_heat_c",
"@type": [
- "http://data.ashrae.org/standard223#Junction"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#Jnc4-ICP"
- },
- {
- "@id": "http://example.org/IBAL#Jnc4-OCP1"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://example.org/IBAL#Jnc4-OCP2"
+ "@id": "http://qudt.org/vocab/quantitykind/Voltage"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Junction 4"
+ "@value": "ahu2 heat c"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_10",
+ "@id": "http://example.org/IBAL#WaterPump_2_OCP",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#Jnc4-OCP2"
- },
- {
- "@id": "http://example.org/IBAL#VAV_4_ICP"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 10"
+ "@value": "Water pump 2 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_328",
+ "@id": "http://example.org/IBAL#zs1_out_rtd",
"@type": [
- "http://data.ashrae.org/standard223#Controller"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/bacnet/2020#description": [
{
- "@id": "http://example.org/IBAL#MotorizedDamper_11"
+ "@value": "Zone1 Temperature"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/bacnet/2020#object-identifier": [
{
- "@id": "http://example.org/IBAL#d7_pos_fb"
+ "@value": "analog-input,5"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/bacnet/2020#object-name": [
{
- "@value": "Channel 328"
+ "@value": "zs1_out_rtd"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#Channel_364",
- "@type": [
- "http://data.ashrae.org/standard223#Controller"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/bacnet/2020#object-type": [
{
- "@id": "http://example.org/IBAL#MotorizedDamper_4"
+ "@value": "analog-input"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/bacnet/2020#objectOf": [
{
- "@id": "http://example.org/IBAL#d18_pos_fb"
+ "@id": "http://example.org/IBAL#HVACZone_1"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/bacnet/2020#present-value": [
{
- "@value": "Channel 364"
+ "@type": "http://www.w3.org/2001/XMLSchema#float",
+ "@value": "70.0"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#Damper_16_ICP",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://example.org/IBAL#MotorizedDamper_16"
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Damper 16 ICP"
+ "@value": "zs1_out_rtd"
}
]
},
{
- "@id": "http://example.org/IBAL#Damper_4_OCP",
+ "@id": "http://example.org/IBAL#Channel_7",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#HumiditySensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://example.org/IBAL#AHU_1_ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#ahu2_rh_up"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Damper 4 OCP"
+ "@value": "Channel 7"
}
]
},
{
- "@id": "http://example.org/IBAL#PlateHeatExchange_1_ConnectionTemperature",
+ "@id": "http://example.org/IBAL#ahu1_on",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasValue": [
- {
- "@type": "http://www.w3.org/2001/XMLSchema#decimal",
- "@value": "60"
- }
- ],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Voltage"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_F"
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Plate heat exchange 1 Connection temperature"
+ "@value": "ahu1 on"
}
]
},
{
- "@id": "http://example.org/IBAL#oau_out_rtd",
+ "@id": "http://example.org/IBAL#Junction_9",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Junction"
],
- "http://data.ashrae.org/standard223#hasValue": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@type": "http://www.w3.org/2001/XMLSchema#decimal",
- "@value": "45"
+ "@id": "http://example.org/IBAL#Jnc9-ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc9-OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc9-OCP2"
}
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_F"
+ "@value": "Junction 9"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_4_E_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/value": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@value": "45"
+ "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "oau out rtd"
+ "@value": "Fan 4 E ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#Junction_24",
+ "@id": "http://example.org/IBAL#Segment_9",
"@type": [
- "http://data.ashrae.org/standard223#Junction"
+ "http://data.ashrae.org/standard223#Connection"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Jnc24-ICP"
- },
- {
- "@id": "http://example.org/IBAL#Jnc24-OCP1"
+ "@id": "http://example.org/IBAL#AHU_2_OCP"
},
{
- "@id": "http://example.org/IBAL#Jnc24-OCP2"
+ "@id": "http://example.org/IBAL#Jnc4-ICP"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Junction 24"
+ "@value": "Segment 9"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_88_Temp",
+ "@id": "http://example.org/IBAL#HVAC_Space_3_OCP",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_F"
+ "@id": "http://example.org/IBAL#Segment_16"
}
],
- "http://qudt.org/schema/qudt/value": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@value": "62"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment_88_Temp"
+ "@value": "HVAC Space 3 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#d11_pos_fb",
+ "@id": "http://example.org/IBAL#Jnc21-ICP2",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositionVector"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "d11 pos fb"
+ "@value": "Jnc21-ICP2"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_83",
+ "@id": "http://example.org/IBAL#HC-3-OutletFlow",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasValue": [
{
- "@id": "http://example.org/IBAL#Jnc31-ICP2"
- },
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "500"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://example.org/IBAL#WaterPump_2_OCP"
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://qudt.org/vocab/unit/PA"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "500"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 83"
+ "@value": "HC 3 OutletFlow"
}
]
},
{
- "@id": "http://example.org/IBAL#PlateHeatExchange_1_Lower_ICP",
+ "@id": "http://example.org/IBAL#VAV_3_OCP",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Plate Heat Exchange 1 Lower ICP"
+ "@value": "VAV 3 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#CC_1_Bypass_Connection",
+ "@id": "http://example.org/IBAL#d10_pos_fb",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
- ],
- "http://data.ashrae.org/standard223#connectsAt": [
- {
- "@id": "http://example.org/IBAL#ManualTwoWayValve_2_OCP"
- },
- {
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_1_ICP_2"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Water-ChilledWater"
+ "@id": "http://qudt.org/vocab/quantitykind/PositionVector"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "CC 1 Bypass Connection"
+ "@value": "d10 pos fb"
}
]
},
{
- "@id": "http://example.org/IBAL#AHU_3_Connection_3",
+ "@id": "http://example.org/IBAL#v13_pos_c",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#connectsAt": [
- {
- "@id": "http://example.org/IBAL#Fan_5_ICP"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://example.org/IBAL#HC_7_OCP"
+ "@id": "http://qudt.org/vocab/quantitykind/Voltage"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "AHU 3 Connection 3"
+ "@value": "v13 pos c"
}
]
},
{
- "@id": "http://example.org/IBAL#AHU_2_G_ICP",
+ "@id": "http://example.org/IBAL#MotorizedDamper_12",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#Segment_56"
- }
+ "http://data.ashrae.org/standard223#Damper"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://example.org/IBAL#Damper_12_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_12_OCP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "AHU 2 G ICP"
+ "@value": "Motorized damper 12"
}
]
},
{
- "@id": "http://example.org/IBAL#ahu1_fan_power",
+ "@id": "http://example.org/IBAL#Jnc33-ICP1",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/W"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "AHU1 Fan Power"
+ "@value": "Jnc33-ICP1"
}
]
},
{
- "@id": "http://example.org/IBAL#VAV_3",
+ "@id": "http://example.org/IBAL#ahu1_cc_rtd",
"@type": [
- "http://data.ashrae.org/bacnet/2020#BACnetDevice",
- "http://data.ashrae.org/standard223#TerminalUnit"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/bacnet/2020#hasPort": [
+ "http://data.ashrae.org/standard223#hasValue": [
{
- "@id": "http://data.ashrae.org/bacnet/2020#P_47813"
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "45"
}
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "http://example.org/IBAL#HeatingCoil_5"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://example.org/IBAL#MotorizedDamper_3"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "http://example.org/IBAL#VAV_3_ICP"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://example.org/IBAL#VAV_3_OCP"
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "VAV 3"
+ "@value": "AHU 1 CC RTD"
}
]
},
{
- "@id": "http://example.org/IBAL#Junction_14",
+ "@id": "http://example.org/IBAL#Junction_3",
"@type": [
"http://data.ashrae.org/standard223#Junction"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Jnc14-ICP1"
+ "@id": "http://example.org/IBAL#Jnc3-ICP1"
},
{
- "@id": "http://example.org/IBAL#Jnc14-ICP2"
+ "@id": "http://example.org/IBAL#Jnc3-ICP2"
},
{
- "@id": "http://example.org/IBAL#Jnc14-OCP"
+ "@id": "http://example.org/IBAL#Jnc3-OCP"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -13831,66 +13740,58 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Junction 14"
+ "@value": "Junction 3"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_78",
+ "@id": "http://example.org/IBAL#ahu2_on",
"@type": [
- "http://data.ashrae.org/standard223#TemperatureSensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://example.org/IBAL#AHU_1_Connection_2"
+ "@id": "http://qudt.org/vocab/quantitykind/Voltage"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://example.org/IBAL#ahu2_heat_rtd"
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 78"
+ "@value": "ahu2 on"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_90",
+ "@id": "http://example.org/IBAL#Fan_2_ICP",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#Jnc33-OCP2"
- },
- {
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_5_ICP_2"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 90"
+ "@value": "Fan 2 ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_3",
+ "@id": "http://example.org/IBAL#Segment_29",
"@type": [
"http://data.ashrae.org/standard223#Connection"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Jnc1-OCP1"
+ "@id": "http://example.org/IBAL#Damper_10_OCP"
},
{
- "@id": "http://example.org/IBAL#Jnc2-ICP"
+ "@id": "http://example.org/IBAL#Jnc10-ICP2"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -13900,418 +13801,397 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 3"
+ "@value": "Segment 29"
}
]
},
{
- "@id": "http://example.org/IBAL#Junction_20",
+ "@id": "http://example.org/IBAL#vav1_t_in",
"@type": [
- "http://data.ashrae.org/standard223#Junction"
+ "http://data.ashrae.org/bacnet/2020#AnalogInputObject",
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#Jnc20-ICP"
- },
- {
- "@id": "http://example.org/IBAL#Jnc20-OCP"
- },
+ "http://data.ashrae.org/bacnet/2020#description": [
{
- "@id": "http://example.org/IBAL#Jnc20-OCP2"
+ "@value": "VAV1 Supply Air Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/bacnet/2020#object-identifier": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@value": "analog-input,3"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/bacnet/2020#object-name": [
{
- "@value": "Junction 20"
+ "@value": "vav1_t_in"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#Segment_5",
- "@type": [
- "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#Damper_5_ICP"
- },
+ "http://data.ashrae.org/bacnet/2020#object-type": [
{
- "@id": "http://example.org/IBAL#Jnc2-OCP"
+ "@value": "analog-input"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/bacnet/2020#objectOf": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://example.org/IBAL#VAV_1"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/bacnet/2020#present-value": [
{
- "@value": "Segment 5"
+ "@type": "http://www.w3.org/2001/XMLSchema#float",
+ "@value": "70.0"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#Channel_87",
- "@type": [
- "http://data.ashrae.org/standard223#TemperatureSensor"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://example.org/IBAL#VAV_1_Connection_2"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://example.org/IBAL#vav1_out_rtd"
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 87"
+ "@value": "vav1 t in"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc10-ICP1",
+ "@id": "http://example.org/IBAL#AHU_2_Connection_3",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#connectsAt": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "http://example.org/IBAL#CC_2_OCP"
+ },
{
- "@value": "Jnc10-ICP1"
+ "@id": "http://example.org/IBAL#Fan_2_ICP"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#ManualTwoWayValve_3_ICP",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Manual two way valve 3 ICP"
+ "@value": "AHU 2 Connection 3"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_21",
+ "@id": "http://example.org/IBAL#AHU_2_Zone",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#Zone"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#Damper_6_ICP"
- },
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://example.org/IBAL#Jnc7-OCP2"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasDomainSpace": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://example.org/IBAL#HVACSpace_3"
+ },
+ {
+ "@id": "http://example.org/IBAL#HVACSpace_4"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 21"
+ "@value": "AHU 2 Zone"
}
]
},
{
- "@id": "http://example.org/IBAL#zs3_rh",
+ "@id": "http://example.org/IBAL#ch1_power",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasValue": [
- {
- "@type": "http://www.w3.org/2001/XMLSchema#decimal",
- "@value": "50"
- }
- ],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "http://qudt.org/vocab/unit/W"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "zs3 rh"
+ "@value": "ch1 power"
}
]
},
{
- "@id": "http://example.org/IBAL#AHU1_FnB",
+ "@id": "http://example.org/IBAL#vav4_out_rtd",
"@type": [
- "http://data.ashrae.org/standard223#FunctionBlock"
+ "http://data.ashrae.org/bacnet/2020#AnalogInputObject",
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasInput": [
- {
- "@id": "http://example.org/IBAL#ahu2_out_rtd"
- },
+ "http://data.ashrae.org/bacnet/2020#description": [
{
- "@id": "http://example.org/IBAL#ahu2_p_down"
- },
+ "@value": "VAV4 Discharge Temperature"
+ }
+ ],
+ "http://data.ashrae.org/bacnet/2020#object-identifier": [
{
- "@id": "http://example.org/IBAL#d15_pos_c"
- },
+ "@value": "analog-input,2"
+ }
+ ],
+ "http://data.ashrae.org/bacnet/2020#object-name": [
{
- "@id": "http://example.org/IBAL#d16_pos_c"
- },
+ "@value": "vav4_out_rtd"
+ }
+ ],
+ "http://data.ashrae.org/bacnet/2020#object-type": [
{
- "@id": "http://example.org/IBAL#v13_pos_fb"
- },
+ "@value": "analog-input"
+ }
+ ],
+ "http://data.ashrae.org/bacnet/2020#objectOf": [
{
- "@id": "http://example.org/IBAL#vav1_heat_c"
- },
+ "@id": "http://example.org/IBAL#VAV_4"
+ }
+ ],
+ "http://data.ashrae.org/bacnet/2020#present-value": [
{
- "@id": "http://example.org/IBAL#vav2_heat_c"
+ "@type": "http://www.w3.org/2001/XMLSchema#float",
+ "@value": "70.0"
}
],
- "http://data.ashrae.org/standard223#hasOutput": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://example.org/IBAL#ahu2_vfd"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://example.org/IBAL#v13_pos_c"
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "AHU1 Fn b"
+ "@value": "vav4 out rtd"
}
]
},
{
- "@id": "http://example.org/IBAL#oau_rh",
+ "@id": "http://example.org/IBAL#CoolingCoil_1",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#CoolingCoil"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "http://example.org/IBAL#CC_1_Water_ICP"
+ },
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "http://example.org/IBAL#CC_1_Water_OCP"
}
],
- "http://qudt.org/schema/qudt/value": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@value": "80"
+ "@id": "http://data.ashrae.org/standard223#Role-Cooling"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "oau rh"
+ "@value": "Cooling coil 1"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_306T",
+ "@id": "http://example.org/IBAL#AHU_1_Connection_2",
"@type": [
- "http://data.ashrae.org/standard223#TemperatureSensor"
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#connectsAt": [
{
- "@id": "http://example.org/IBAL#Segment_27"
+ "@id": "http://example.org/IBAL#CC_1_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_1_OCP"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#exf1_t_in"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 306T"
+ "@value": "AHU 1 Connection 2"
}
]
},
{
- "@id": "http://example.org/IBAL#ahu2_t_ra",
+ "@id": "http://example.org/IBAL#VFD_4_ICP",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_F"
+ "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "ahu2 t ra"
+ "@value": "VFD 4 ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#MotorizedDamper_9",
+ "@id": "http://example.org/IBAL#Fan_4_VFD_4",
"@type": [
- "http://data.ashrae.org/standard223#Damper"
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Damper_9_ICP"
+ "@id": "http://example.org/IBAL#Fan_4_E_ICP"
},
{
- "@id": "http://example.org/IBAL#Damper_9_OCP"
+ "@id": "http://example.org/IBAL#VFD_4_OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Motorized damper 9"
+ "@value": "Fan 4 VFD 4"
}
]
},
{
- "@id": "http://example.org/IBAL#PlateHetExchange_1_Bypass_Connection",
+ "@id": "http://example.org/IBAL#HC_1_OCP",
"@type": [
- "http://data.ashrae.org/standard223#Pipe"
- ],
- "http://data.ashrae.org/standard223#connectsAt": [
- {
- "@id": "http://example.org/IBAL#ManualTwoWayValve_3_OCP"
- },
- {
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_3_ICP_2"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-ChilledWater"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Plate Heat Exchange 1 Bypass Connection"
+ "@value": "HC 1 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_326T",
+ "@id": "http://example.org/IBAL#exf2_p_up",
"@type": [
- "http://data.ashrae.org/standard223#TemperatureSensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://example.org/IBAL#Segment_38"
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://example.org/IBAL#ahu1_t_sa"
+ "@id": "http://qudt.org/vocab/unit/PA"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 326T"
+ "@value": "exf2 p up"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_41",
+ "@id": "http://example.org/IBAL#Channel_3",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#HumiditySensor"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#Damper_13_OCP"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#Jnc14-ICP1"
+ "@id": "http://example.org/IBAL#HC_4_ICP"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://example.org/IBAL#ahu1_rh_up"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 41"
+ "@value": "Channel 3"
}
]
},
{
- "@id": "http://example.org/IBAL#d18_pos_c",
+ "@id": "http://example.org/IBAL#MotorizedDamper_8",
"@type": [
- "http://data.ashrae.org/bacnet/2020#AnalogOutputObject",
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Damper"
],
- "http://data.ashrae.org/bacnet/2020#description": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@value": "VAV4 Damper Control Signal"
- }
- ],
- "http://data.ashrae.org/bacnet/2020#object-identifier": [
+ "@id": "http://example.org/IBAL#Damper_8_ICP"
+ },
{
- "@value": "analog-output,2"
+ "@id": "http://example.org/IBAL#Damper_8_OCP"
}
],
- "http://data.ashrae.org/bacnet/2020#object-name": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "d18_pos_c"
+ "@value": "Motorized damper 8"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_90",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/bacnet/2020#object-type": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@value": "analog-output"
+ "@id": "http://example.org/IBAL#Jnc33-OCP2"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_5_ICP_2"
}
],
- "http://data.ashrae.org/bacnet/2020#objectOf": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#VAV_4"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
- "http://data.ashrae.org/bacnet/2020#present-value": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@type": "http://www.w3.org/2001/XMLSchema#float",
- "@value": "0.0"
+ "@value": "Segment 90"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Channel_86",
+ "@type": [
+ "http://data.ashrae.org/standard223#TemperatureSensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Voltage"
+ "@id": "http://example.org/IBAL#Segment_44"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "http://example.org/IBAL#oau_out_rtd"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "d18 pos c"
+ "@value": "Channel 86"
}
]
},
{
- "@id": "http://example.org/IBAL#WaterPump_2_ICP",
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_3_ICP",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -14322,70 +14202,75 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Water pump 2 ICP"
+ "@value": "Manual two way valve 3 ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#VAV_4_ICP",
+ "@id": "http://example.org/IBAL#CC_2_OCP",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#CoolingCoil_2"
+ }
+ ],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "VAV 4 ICP"
+ "@value": " CC 2 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#HVACZone_2",
+ "@id": "http://example.org/IBAL#Channel_381",
"@type": [
- "http://data.ashrae.org/standard223#Zone"
+ "http://data.ashrae.org/standard223#Controller"
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_5"
}
],
- "http://data.ashrae.org/standard223#hasDomainSpace": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#HVACSpace_2"
+ "@id": "http://example.org/IBAL#v8_pos_c"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "HVACZone 2"
+ "@value": "Channel 381"
}
]
},
{
- "@id": "http://example.org/IBAL#exf1_on",
+ "@id": "http://example.org/IBAL#Damper_16_OCP",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Voltage"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "http://example.org/IBAL#MotorizedDamper_16"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "exf1 on"
+ "@value": "Damper 16 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc6-ICP2",
+ "@id": "http://example.org/IBAL#Jnc17-ICP",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -14396,21 +14281,42 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc6-ICP2"
+ "@value": "Jnc17-ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Channel_306",
+ "@type": [
+ "http://data.ashrae.org/standard223#FlowSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#Segment_27"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#exf1_f"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Channel 306"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_14",
+ "@id": "http://example.org/IBAL#VAV_4_Connection_2",
"@type": [
"http://data.ashrae.org/standard223#Connection"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#HVAC_Space_2_OCP"
+ "@id": "http://example.org/IBAL#HVAC_Space_4_ICP"
},
{
- "@id": "http://example.org/IBAL#Jnc5-ICP2"
+ "@id": "http://example.org/IBAL#VAV_4_OCP"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -14420,91 +14326,83 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 14"
+ "@value": "VAV 4 Connection 2"
}
]
},
{
- "@id": "http://example.org/IBAL#ch1_e_out_rtd",
+ "@id": "http://example.org/IBAL#HVACZone_4",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Zone"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasDomainSpace": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_F"
+ "@id": "http://example.org/IBAL#HVACSpace_4"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "ch1 e out rtd"
+ "@value": "HVACZone 4"
}
]
},
{
- "@id": "http://example.org/IBAL#Chiller_2_Lower_Connection",
+ "@id": "http://example.org/IBAL#ahu1_in_rtd",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#connectsAt": [
+ "http://data.ashrae.org/standard223#hasValue": [
{
- "@id": "http://example.org/IBAL#Chiller_2_Lower_OCP"
- },
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "45"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://example.org/IBAL#WaterPump_3_ICP"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Water-ChilledWater"
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Chiller 2 Lower Connection"
+ "@value": "AHU 1 In RTD"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_105",
+ "@id": "http://example.org/IBAL#exf2_t_in",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#AHU_1_G_OCP"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_1_ICP_1"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 105"
+ "@value": "exf2 t in"
}
]
},
{
- "@id": "http://example.org/IBAL#AHU_2_Connection_3",
+ "@id": "http://example.org/IBAL#Jnc10-OCP",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
- ],
- "http://data.ashrae.org/standard223#connectsAt": [
- {
- "@id": "http://example.org/IBAL#CC_2_OCP"
- },
- {
- "@id": "http://example.org/IBAL#Fan_2_ICP"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -14513,14 +14411,14 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "AHU 2 Connection 3"
+ "@value": "Jnc10-OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#HC_5_ICP",
+ "@id": "http://example.org/IBAL#AHU_1_OCP",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -14529,99 +14427,72 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "HC 5 ICP"
+ "@value": "AHU 1 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_20",
+ "@id": "http://example.org/IBAL#Channel_308T",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#TemperatureSensor"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#Damper_12_ICP"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#Jnc7-OCP1"
+ "@id": "http://example.org/IBAL#Segment_10"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://example.org/IBAL#vav4_t_in"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 20"
+ "@value": "Channel 308T"
}
]
},
{
- "@id": "http://example.org/IBAL#ahu1_vfd",
+ "@id": "http://example.org/IBAL#ch1_e_in_rtd",
"@type": [
- "http://data.ashrae.org/bacnet/2020#AnalogOutputObject",
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/bacnet/2020#description": [
- {
- "@value": "AHU1 Fan Speed"
- }
- ],
- "http://data.ashrae.org/bacnet/2020#object-identifier": [
- {
- "@value": "analog-output,1"
- }
- ],
- "http://data.ashrae.org/bacnet/2020#object-name": [
- {
- "@value": "ahu1_vfd"
- }
- ],
- "http://data.ashrae.org/bacnet/2020#object-type": [
- {
- "@value": "analog-output"
- }
- ],
- "http://data.ashrae.org/bacnet/2020#objectOf": [
- {
- "@id": "http://example.org/IBAL#AHU_2"
- }
- ],
- "http://data.ashrae.org/bacnet/2020#present-value": [
- {
- "@type": "http://www.w3.org/2001/XMLSchema#float",
- "@value": "30.0"
- }
- ],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Voltage"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "ahu1 vfd"
+ "@value": "ch1 e in rtd"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_29",
+ "@id": "http://example.org/IBAL#WaterPump_2_ICP",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#Damper_10_OCP"
- },
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://example.org/IBAL#Jnc10-ICP2"
+ "@value": "Water pump 2 ICP"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_7_W_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -14630,175 +14501,179 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 29"
+ "@value": "HC 7 W ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#oau_p_down",
+ "@id": "http://example.org/IBAL#ahu2_p_down",
"@type": [
+ "http://data.ashrae.org/bacnet/2020#AnalogInputObject",
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasValue": [
+ "http://data.ashrae.org/bacnet/2020#description": [
{
- "@type": "http://www.w3.org/2001/XMLSchema#decimal",
- "@value": "11270"
+ "@value": "Static Pressure Measurement Downstream Fan"
}
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/bacnet/2020#object-identifier": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ "@value": "analog-input,3"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/bacnet/2020#object-name": [
{
- "@id": "http://qudt.org/vocab/unit/PA"
+ "@value": "ahu2_p_down"
}
],
- "http://qudt.org/schema/qudt/value": [
+ "http://data.ashrae.org/bacnet/2020#object-type": [
{
- "@value": "11270"
+ "@value": "analog-input"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/bacnet/2020#objectOf": [
{
- "@value": "oau p down"
+ "@id": "http://example.org/IBAL#AHU_1"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#Damper_10_ICP",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/bacnet/2020#present-value": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@type": "http://www.w3.org/2001/XMLSchema#float",
+ "@value": "0.0"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PA"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Damper 10 ICP"
+ "@value": "ahu2 p down"
}
]
},
{
- "@id": "http://example.org/IBAL#Junction_15",
+ "@id": "http://example.org/IBAL#Fan_3",
"@type": [
- "http://data.ashrae.org/standard223#Junction"
+ "http://data.ashrae.org/standard223#Fan"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://example.org/IBAL#Jnc15-ICP"
+ "@id": "http://example.org/IBAL#Fan_3_E_ICP"
},
{
- "@id": "http://example.org/IBAL#Jnc15-OCP1"
+ "@id": "http://example.org/IBAL#Fan_3_ICP"
},
{
- "@id": "http://example.org/IBAL#Jnc15-OCP2"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://example.org/IBAL#Fan_3_OCP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Junction 15"
+ "@value": "Fan 3"
}
]
},
{
- "@id": "http://example.org/IBAL#VFD_3_OCP",
+ "@id": "http://example.org/IBAL#Jnc15-ICP",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "VFD 3 OCP"
+ "@value": "Jnc15-ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_18",
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_2_OCP",
"@type": [
- "http://data.ashrae.org/standard223#ElectricMeter"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#VFD_3"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
{
- "@id": "http://example.org/IBAL#exf1_power"
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_2"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 18"
+ "@value": "Motorized three way valve 2 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_130",
+ "@id": "http://example.org/IBAL#WaterChiller_1",
"@type": [
- "http://data.ashrae.org/standard223#TemperatureSensor"
+ "http://data.ashrae.org/standard223#Chiller"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#Chiller_1_Lower_ICP"
+ },
{
- "@id": "http://example.org/IBAL#PlateHeatExchange_1_Connection"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
+ "@id": "http://example.org/IBAL#Chiller_1_Lower_OCP"
+ },
{
- "@id": "http://example.org/IBAL#hx1_pg_rtd"
+ "@id": "http://example.org/IBAL#Chiller_1_Upper_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Chiller_1_Upper_OCP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 130"
+ "@value": "Water Chiller 1"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_75",
+ "@id": "http://example.org/IBAL#Jnc2-OCP1",
"@type": [
- "http://data.ashrae.org/standard223#TemperatureSensor"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#AHU_2_Connection_3"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
{
- "@id": "http://example.org/IBAL#ahu1_cc_rtd"
+ "@id": "http://example.org/IBAL#Junction_2"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 75"
+ "@value": "Jnc2-OCP1"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_24",
+ "@id": "http://example.org/IBAL#Segment_20",
"@type": [
"http://data.ashrae.org/standard223#Connection"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Damper_8_ICP"
+ "@id": "http://example.org/IBAL#Damper_12_ICP"
},
{
- "@id": "http://example.org/IBAL#Jnc8-OCP2"
+ "@id": "http://example.org/IBAL#Jnc7-OCP1"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -14808,82 +14683,93 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 24"
+ "@value": "Segment 20"
}
]
},
{
- "@id": "http://example.org/IBAL#exf2_p_up",
+ "@id": "http://example.org/IBAL#AHU_1_Zone",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Zone"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasDomainSpace": [
{
- "@id": "http://qudt.org/vocab/unit/PA"
+ "@id": "http://example.org/IBAL#HVACSpace_1"
+ },
+ {
+ "@id": "http://example.org/IBAL#HVACSpace_2"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "exf2 p up"
+ "@value": "AHU 1 Zone"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_451",
+ "@id": "http://example.org/IBAL#Jnc11-OCP",
"@type": [
- "http://data.ashrae.org/standard223#Controller"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "http://example.org/IBAL#VFD_1"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#ahu2_vfd"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 451"
+ "@value": "Jnc11-OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc22-OCP1",
+ "@id": "http://example.org/IBAL#VFD_3_ICP",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc22-OCP1"
+ "@value": "VFD 3 ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#Junction_2",
+ "@id": "http://example.org/IBAL#MotorizedDamper_16",
"@type": [
- "http://data.ashrae.org/standard223#Junction"
+ "http://data.ashrae.org/standard223#Damper"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://example.org/IBAL#Jnc2-ICP"
+ "@id": "http://example.org/IBAL#Damper_16_ICP"
},
{
- "@id": "http://example.org/IBAL#Jnc2-OCP"
- },
+ "@id": "http://example.org/IBAL#Damper_16_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://example.org/IBAL#Jnc2-OCP2"
+ "@value": "Motorized damper 16"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc14-OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Segment_42"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -14893,109 +14779,123 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Junction 2"
+ "@value": "Jnc14-OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Chiller_1_Lower_OCP",
+ "@id": "http://example.org/IBAL#Damper_10_OCP",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-ChilledWater"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Chiller 1 Lower OCP"
+ "@value": "Damper 10 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#VAV2_FnB",
+ "@id": "http://example.org/IBAL#ahu2_cc_rtd",
"@type": [
- "http://data.ashrae.org/standard223#FunctionBlock"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasInput": [
- {
- "@id": "http://example.org/IBAL#d16_pos_fb"
- },
- {
- "@id": "http://example.org/IBAL#vav2_f"
- },
- {
- "@id": "http://example.org/IBAL#vav2_out_rtd"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://example.org/IBAL#vav2_t_in"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://example.org/IBAL#zs2_out_rtd"
- },
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://example.org/IBAL#zs2_t_sp_f"
+ "@value": "ahu2 cc rtd"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_2_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasOutput": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#d16_pos_c"
- },
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://example.org/IBAL#vav2_heat_c"
+ "@id": "http://example.org/IBAL#VAV_2_ICP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "VAV2 Fn b"
+ "@value": "Damper 2 ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_79",
+ "@id": "http://example.org/IBAL#ahu1_t_sa",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasValue": [
{
- "@id": "http://example.org/IBAL#Chiller_2_Lower_ICP"
- },
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "60"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://example.org/IBAL#Jnc29-OCP"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 79"
+ "@value": "AHU 1 T SA"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc8-OCP1",
+ "@id": "http://example.org/IBAL#Jnc35-ICP1",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc8-OCP1"
+ "@value": "Jnc35-ICP1"
}
]
},
{
- "@id": "http://example.org/IBAL#Damper_17_ICP",
+ "@id": "http://example.org/IBAL#Segment_50",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Damper_18_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc17-ICP2"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -15004,172 +14904,168 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Damper 17 ICP"
+ "@value": "Segment 50"
}
]
},
{
- "@id": "http://example.org/IBAL#d18_pos_fb",
+ "@id": "http://example.org/IBAL#Channel_395gw",
"@type": [
- "http://data.ashrae.org/bacnet/2020#AnalogInputObject",
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Controller"
],
- "http://data.ashrae.org/bacnet/2020#description": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@value": "VAV4 Damper Feedback Signal"
+ "@id": "http://example.org/IBAL#AHU_3"
}
],
- "http://data.ashrae.org/bacnet/2020#object-identifier": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@value": "analog-input,1"
+ "@id": "http://example.org/IBAL#ahu2_on"
}
],
- "http://data.ashrae.org/bacnet/2020#object-name": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "d18_pos_fb"
+ "@value": "Channel 395gw"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc15-OCP1",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/bacnet/2020#object-type": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@value": "analog-input"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/bacnet/2020#objectOf": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://example.org/IBAL#VAV_4"
+ "@value": "Jnc15-OCP1"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#VAV_1",
+ "@type": [
+ "http://data.ashrae.org/bacnet/2020#BACnetDevice",
+ "http://data.ashrae.org/standard223#TerminalUnit"
],
- "http://data.ashrae.org/bacnet/2020#present-value": [
+ "http://data.ashrae.org/bacnet/2020#hasPort": [
{
- "@type": "http://www.w3.org/2001/XMLSchema#float",
- "@value": "0.0"
+ "@id": "http://data.ashrae.org/bacnet/2020#P_47811"
}
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Voltage"
+ "@id": "http://example.org/IBAL#HeatingCoil_2"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_1"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "http://example.org/IBAL#VAV_1_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#VAV_1_OCP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "d18 pos fb"
+ "@value": "VAV 1"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_308",
+ "@id": "http://example.org/IBAL#Channel_77",
"@type": [
- "http://data.ashrae.org/standard223#FlowSensor"
+ "http://data.ashrae.org/standard223#TemperatureSensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#Segment_10"
+ "@id": "http://example.org/IBAL#AHU_1_ICP"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#vav4_f"
+ "@id": "http://example.org/IBAL#ahu2_in_rtd"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 308"
+ "@value": "Channel 77"
}
]
},
{
- "@id": "http://example.org/IBAL#VAV_4_OCP",
+ "@id": "http://example.org/IBAL#Channel_335",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Controller"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#VAV_4_Connection_2"
+ "@id": "http://example.org/IBAL#MotorizedDamper_12"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://example.org/IBAL#d8_pos_fb"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "VAV 4 OCP"
+ "@value": "Channel 335"
}
]
},
{
- "@id": "http://example.org/IBAL#exf1_vfd",
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_4_OCP",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Voltage"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "exf1 vfd"
+ "@value": "Manual two way valve 4 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#ReturnAir-1-Flow",
+ "@id": "http://example.org/IBAL#Jnc28-OCP2",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasValue": [
- {
- "@type": "http://www.w3.org/2001/XMLSchema#decimal",
- "@value": "500"
- }
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
- {
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/value": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@value": "500"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Return Air 1 Flow"
+ "@value": "Jnc28-OCP2"
}
]
},
{
- "@id": "http://example.org/IBAL#Junction_18",
+ "@id": "http://example.org/IBAL#Junction_28",
"@type": [
"http://data.ashrae.org/standard223#Junction"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Jnc18-ICP"
+ "@id": "http://example.org/IBAL#Jnc28-ICP"
},
{
- "@id": "http://example.org/IBAL#Jnc18-OCP"
+ "@id": "http://example.org/IBAL#Jnc28-OCP1"
},
{
- "@id": "http://example.org/IBAL#Jnc18-OCP2"
+ "@id": "http://example.org/IBAL#Jnc28-OCP2"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -15179,60 +15075,33 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Junction 18"
- }
- ]
- },
- {
- "@id": "http://example.org/IBAL#Channel_426",
- "@type": [
- "http://data.ashrae.org/standard223#Controller"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "http://example.org/IBAL#MotorizedDamper_6"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
- {
- "@id": "http://example.org/IBAL#d11_pos_c"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "Channel 426"
+ "@value": "Junction 28"
}
]
},
{
- "@id": "http://example.org/IBAL#Junction_13",
+ "@id": "http://example.org/IBAL#CC_2_Water_OCP",
"@type": [
- "http://data.ashrae.org/standard223#Junction"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#Jnc13-ICP1"
- },
- {
- "@id": "http://example.org/IBAL#Jnc13-ICP2"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#Jnc13-OCP"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://example.org/IBAL#AHU_2_G_OCP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Junction 13"
+ "@value": " CC 2 Water OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc14-ICP2",
+ "@id": "http://example.org/IBAL#HC_2_ICP",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -15243,133 +15112,139 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc14-ICP2"
+ "@value": "HC 2 ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_3",
+ "@id": "http://example.org/IBAL#Segment_103",
"@type": [
- "http://data.ashrae.org/standard223#ThreeWayValve"
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_3_ICP_1"
+ "@id": "http://example.org/IBAL#AHU_1_G_ICP"
},
{
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_3_ICP_2"
- },
+ "@id": "http://example.org/IBAL#Jnc19-OCP2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_3_OCP"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Motorized three way valve 3"
+ "@value": "Segment 103"
}
]
},
{
- "@id": "http://example.org/IBAL#HVAC_Space_4_ICP",
+ "@id": "http://example.org/IBAL#Channel_301T",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#TemperatureSensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://example.org/IBAL#Segment_1"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#vav1_t_in"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "HVAC Space 4 ICP"
+ "@value": "Channel 301T"
}
]
},
{
- "@id": "http://example.org/IBAL#AHU_3",
+ "@id": "http://example.org/IBAL#CoolingCoil_3",
"@type": [
- "http://data.ashrae.org/standard223#AirHandlingUnit"
- ],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "http://example.org/IBAL#CoolingCoil_3"
- },
- {
- "@id": "http://example.org/IBAL#Fan_5"
- },
- {
- "@id": "http://example.org/IBAL#HeatingCoil_7"
- },
- {
- "@id": "http://example.org/IBAL#VFD_5"
- }
+ "http://data.ashrae.org/standard223#CoolingCoil"
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://example.org/IBAL#AHU_3_G_ICP"
+ "@id": "http://example.org/IBAL#CC_3_ICP"
},
{
- "@id": "http://example.org/IBAL#AHU_3_G_OCP"
+ "@id": "http://example.org/IBAL#CC_3_OCP"
},
{
- "@id": "http://example.org/IBAL#AHU_3_ICP"
+ "@id": "http://example.org/IBAL#CC_3_W_ICP"
},
{
- "@id": "http://example.org/IBAL#AHU_3_OCP"
+ "@id": "http://example.org/IBAL#CC_3_W_OCP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "AHU 3"
+ "@value": "Cooling coil 3"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc7-OCP2",
+ "@id": "http://example.org/IBAL#Junction_30",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Junction"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc30-ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc30-ICP2"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc30-OCP"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc7-OCP2"
+ "@value": "Junction 30"
}
]
},
{
- "@id": "http://example.org/IBAL#WaterPump_4_ICP",
+ "@id": "http://example.org/IBAL#Channel_334",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#FlowSensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://example.org/IBAL#Segment_20"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#ahu2_f_ra"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Water pump 4 ICP"
+ "@value": "Channel 334"
}
]
},
{
- "@id": "http://example.org/IBAL#Junction_38",
+ "@id": "http://example.org/IBAL#Segment_76",
"@type": [
- "http://data.ashrae.org/standard223#Junction"
+ "http://data.ashrae.org/standard223#Connection"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Jnc38-ICP"
- },
- {
- "@id": "http://example.org/IBAL#Jnc38-OCP"
+ "@id": "http://example.org/IBAL#Jnc26-OCP"
},
{
- "@id": "http://example.org/IBAL#Jnc38-OCP2"
+ "@id": "http://example.org/IBAL#Jnc28-ICP"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -15379,61 +15254,61 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Junction 38"
+ "@value": "Segment 76"
}
]
},
{
- "@id": "http://example.org/IBAL#MotorizedDamper_7",
+ "@id": "http://example.org/IBAL#Segment_77",
"@type": [
- "http://data.ashrae.org/standard223#Damper"
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Damper_7_ICP"
+ "@id": "http://example.org/IBAL#Jnc28-OCP1"
},
{
- "@id": "http://example.org/IBAL#Damper_7_OCP"
+ "@id": "http://example.org/IBAL#Jnc29-ICP"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@value": "Motorized damper 7"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#VAV_2_Connection_2",
- "@type": [
- "http://data.ashrae.org/standard223#Connection"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#HVAC_Space_2_ICP"
- },
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://example.org/IBAL#VAV_2_OCP"
+ "@value": "Segment 77"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#d8_pos_fb",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/PositionVector"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "VAV 2 Connection 2"
+ "@value": "d8 pos fb"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc21-ICP1",
+ "@id": "http://example.org/IBAL#Segment_107",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Connection"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Segment_61"
+ "@id": "http://example.org/IBAL#Jnc23-ICP2"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_3_OCP"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -15443,110 +15318,107 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc21-ICP1"
+ "@value": "Segment 107"
}
]
},
{
- "@id": "http://example.org/IBAL#HC_1_W_ICP",
+ "@id": "http://example.org/IBAL#Jnc14-ICP2",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "HC 1 W ICP"
+ "@value": "Jnc14-ICP2"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc1-OCP1",
+ "@id": "http://example.org/IBAL#Segment_42",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Connection"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
+ "http://data.ashrae.org/standard223#lnx": [
+ {
+ "@id": "http://example.org/IBAL#HC_4_ICP"
+ }
+ ],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc1-OCP1"
+ "@value": "Segment 42"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_127",
+ "@id": "http://example.org/IBAL#Channel_18",
"@type": [
- "http://data.ashrae.org/standard223#TemperatureSensor"
+ "http://data.ashrae.org/standard223#ElectricMeter"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#Segment_104"
+ "@id": "http://example.org/IBAL#VFD_3"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#ts_out_rtd"
+ "@id": "http://example.org/IBAL#exf1_power"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 127"
+ "@value": "Channel 18"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_78",
+ "@id": "http://example.org/IBAL#ThermalStorage_1_ICP",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Chiller_1_Lower_ICP"
- },
- {
- "@id": "http://example.org/IBAL#Jnc28-OCP2"
+ "@id": "http://example.org/IBAL#Segment_89"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 78"
+ "@value": "Thermal Storage 1 ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_325",
+ "@id": "http://example.org/IBAL#WaterPump_1_ICP",
"@type": [
- "http://data.ashrae.org/standard223#FlowSensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "http://example.org/IBAL#Segment_23"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#ahu1_f_ra"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 325"
+ "@value": "Water pump 1 ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#HC_3_OCP",
+ "@id": "http://example.org/IBAL#HC_5_OCP",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -15557,112 +15429,129 @@
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://example.org/IBAL#VAV_2_OCP"
+ "@id": "http://example.org/IBAL#VAV_3_OCP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "HC 3 OCP"
+ "@value": "HC 5 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Fan_2_S_ICP",
+ "@id": "http://example.org/IBAL#PlateHeatExchange_2_Upper_ICP",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Electricity-Signal"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Fan 2 S ICP"
+ "@value": "Plate Heat Exchange 2 Upper ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#Fan_1",
+ "@id": "http://example.org/IBAL#ahu2_rh_up",
"@type": [
- "http://data.ashrae.org/standard223#Fan"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "http://example.org/IBAL#Fan_1_ICP"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://example.org/IBAL#Fan_1_OCP"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://example.org/IBAL#Fan_1_S_ICP"
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Fan 1"
+ "@value": "ahu2 rh up"
}
]
},
{
- "@id": "http://example.org/IBAL",
+ "@id": "http://example.org/IBAL#Channel_109",
"@type": [
- "http://www.w3.org/2002/07/owl#Ontology"
+ "http://data.ashrae.org/standard223#TemperatureSensor"
],
- "http://www.w3.org/2002/07/owl#imports": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223/1.0/model/all"
+ "@id": "http://example.org/IBAL#HVAC_Space_3_ICP"
}
],
- "http://www.w3.org/2002/07/owl#versionInfo": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@value": "Created with TopBraid Composer"
+ "@id": "http://example.org/IBAL#zs3_heat_rtd"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Channel 109"
}
]
},
{
- "@id": "http://example.org/IBAL#HC_6_W_OCP",
+ "@id": "http://example.org/IBAL#Segment_88",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc32-OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc33-ICP1"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "HC 6 W OCP"
+ "@value": "Segment 88"
}
]
},
{
- "@id": "http://example.org/IBAL#MotorizedDamper_16",
+ "@id": "http://example.org/IBAL#ahu2_rh_down",
"@type": [
- "http://data.ashrae.org/standard223#Damper"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://example.org/IBAL#Damper_16_ICP"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://example.org/IBAL#Damper_16_OCP"
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Motorized damper 16"
+ "@value": "ahu2 rh down"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc14-OCP",
+ "@id": "http://example.org/IBAL#Segment_1",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Connection"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Segment_42"
+ "@id": "http://example.org/IBAL#AHU_1_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc1-ICP"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -15672,81 +15561,119 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc14-OCP"
+ "@value": "Segment 1"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_4",
+ "@id": "http://example.org/IBAL#CoolingCoil_2",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#CoolingCoil"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://example.org/IBAL#Jnc2-OCP2"
+ "@id": "http://example.org/IBAL#CC_2_ICP"
},
{
- "@id": "http://example.org/IBAL#VAV_2_ICP"
+ "@id": "http://example.org/IBAL#CC_2_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#CC_2_Water_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#CC_2_Water_OCP"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@value": "Cooling coil 2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#exf1_power",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Power"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/W"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 4"
+ "@value": "exf1 power"
}
]
},
{
- "@id": "http://example.org/IBAL#PlateHeatExchange_2_Upper_ICP",
+ "@id": "http://example.org/IBAL#d6_pos_c",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/PositionVector"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Plate Heat Exchange 2 Upper ICP"
+ "@value": "d6 pos c"
}
]
},
{
- "@id": "http://example.org/IBAL#ManualTwoWayValve_1",
+ "@id": "http://example.org/IBAL#Junction_6",
"@type": [
- "http://data.ashrae.org/standard223#TwoWayValve"
+ "http://data.ashrae.org/standard223#Junction"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#ManualTwoWayValve_1_ICP"
+ "@id": "http://example.org/IBAL#Jnc6-ICP1"
},
{
- "@id": "http://example.org/IBAL#ManualTwoWayValve_1_OCP"
+ "@id": "http://example.org/IBAL#Jnc6-ICP2"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc6-OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Manual two way valve 1"
+ "@value": "Junction 6"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_57",
+ "@id": "http://example.org/IBAL#Jnc27-ICP",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#Jnc18-OCP2"
- },
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://example.org/IBAL#ManualTwoWayValve_1_ICP"
+ "@value": "Jnc27-ICP"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_1_W_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -15755,359 +15682,373 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 57"
+ "@value": "HC 1 W OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_49",
+ "@id": "http://example.org/IBAL#WaterPump_3",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#Pump"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://example.org/IBAL#Damper_18_ICP"
+ "@id": "http://example.org/IBAL#WaterPump_3_ICP"
},
{
- "@id": "http://example.org/IBAL#Jnc16-OCP2"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://example.org/IBAL#WaterPump_3_OCP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 49"
+ "@value": "Water pump 3"
}
]
},
{
- "@id": "http://example.org/IBAL#ahu2_p_up",
+ "@id": "http://example.org/IBAL#d10_pos_c",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PA"
+ "@id": "http://qudt.org/vocab/unit/A"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "ahu2 p up"
+ "@value": "d10 pos c"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_59",
+ "@id": "http://example.org/IBAL#zs4_rh",
"@type": [
- "http://data.ashrae.org/standard223#ElectricMeter"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasValue": [
{
- "@id": "http://example.org/IBAL#VFD_2"
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "30"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://example.org/IBAL#ahu1_fan_power"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 59"
+ "@value": "zsh4 rh"
}
]
},
{
- "@id": "http://example.org/IBAL#MotorizedDamper_4",
+ "@id": "http://example.org/IBAL#Damper_5_OCP",
"@type": [
- "http://data.ashrae.org/standard223#Damper"
- ],
- "http://data.ashrae.org/standard223#commandedByProperty": [
- {
- "@id": "http://example.org/IBAL#d18_pos_c"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "http://example.org/IBAL#Damper_4_ICP"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#Damper_4_OCP"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
{
- "@value": "IBAL:VAV4_ICP"
+ "@id": "http://example.org/IBAL#MotorizedDamper_5"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Motorized damper 4"
+ "@value": "Damper 5 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_306",
+ "@id": "http://example.org/IBAL#HC_5_E_ICP",
"@type": [
- "http://data.ashrae.org/standard223#FlowSensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "http://example.org/IBAL#Segment_27"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#exf1_f"
+ "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 306"
+ "@value": "HC 5 E ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#ahu1_f_cc",
+ "@id": "http://example.org/IBAL#oau_p_down",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://data.ashrae.org/standard223#hasValue": [
{
"@type": "http://www.w3.org/2001/XMLSchema#decimal",
- "@value": "40"
+ "@value": "11270"
}
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/GAL_US-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/PA"
}
],
"http://qudt.org/schema/qudt/value": [
{
- "@value": "40"
+ "@value": "11270"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 197"
+ "@value": "oau p down"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc34-OCP1",
+ "@id": "http://example.org/IBAL#d11_pos_c",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/A"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc34-OCP1"
+ "@value": "d11 pos c"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_411",
+ "@id": "http://example.org/IBAL#VAV_1_ICP",
"@type": [
- "http://data.ashrae.org/standard223#Controller"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_2"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#v13_pos_c"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 411"
+ "@value": "VAV 1 ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_67",
+ "@id": "http://example.org/IBAL#HC_7_OCP",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#Jnc23-OCP"
- },
- {
- "@id": "http://example.org/IBAL#Jnc24-ICP"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 67"
+ "@value": "HC 7OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc33-ICP1",
+ "@id": "http://example.org/IBAL#PlateHeatExchange_1_Lower_OCP",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc33-ICP1"
+ "@value": "Plate Heat Exchange 1 Lower OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#VFD_2_OCP",
+ "@id": "http://example.org/IBAL#exf1_vfd",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
+ "@id": "http://qudt.org/vocab/quantitykind/Voltage"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "VFD 2 OCP"
+ "@value": "exf1 vfd"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_93",
+ "@id": "http://example.org/IBAL#VAV2_FnB",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#FunctionBlock"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasInput": [
{
- "@id": "http://example.org/IBAL#Jnc34-OCP1"
+ "@id": "http://example.org/IBAL#d16_pos_fb"
},
{
- "@id": "http://example.org/IBAL#Jnc35-ICP2"
+ "@id": "http://example.org/IBAL#vav2_f"
+ },
+ {
+ "@id": "http://example.org/IBAL#vav2_out_rtd"
+ },
+ {
+ "@id": "http://example.org/IBAL#vav2_t_in"
+ },
+ {
+ "@id": "http://example.org/IBAL#zs2_out_rtd"
+ },
+ {
+ "@id": "http://example.org/IBAL#zs2_t_sp_f"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasOutput": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://example.org/IBAL#d16_pos_c"
+ },
+ {
+ "@id": "http://example.org/IBAL#vav2_heat_c"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 93"
+ "@value": "VAV2 Fn b"
}
]
},
{
- "@id": "http://example.org/IBAL#vav3_out_rtd",
+ "@id": "http://example.org/IBAL#Jnc37-OCP2",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/bacnet/2020#description": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@value": "VAV3 Discharge Temperature"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
- "http://data.ashrae.org/bacnet/2020#object-identifier": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "analog-input,89"
+ "@value": "Jnc37-OCP2"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Channel_364AO",
+ "@type": [
+ "http://data.ashrae.org/standard223#Controller"
],
- "http://data.ashrae.org/bacnet/2020#object-name": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@value": "VAV3-T"
+ "@id": "http://example.org/IBAL#MotorizedDamper_4"
}
],
- "http://data.ashrae.org/bacnet/2020#object-type": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@value": "analog-input"
+ "@id": "http://example.org/IBAL#d18_pos_c"
}
],
- "http://data.ashrae.org/bacnet/2020#objectOf": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://example.org/IBAL#VAV_3"
+ "@value": "Channel 364AO"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#AHU_2",
+ "@type": [
+ "http://data.ashrae.org/standard223#AirHandlingUnit"
],
- "http://data.ashrae.org/bacnet/2020#present-value": [
+ "http://data.ashrae.org/bacnet/2020#hasPort": [
{
- "@type": "http://www.w3.org/2001/XMLSchema#float",
- "@value": "55.0"
+ "@id": "http://data.ashrae.org/bacnet/2020#P_47815"
}
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "http://example.org/IBAL#CoolingCoil_2"
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_2"
+ },
+ {
+ "@id": "http://example.org/IBAL#HeatingCoil_4"
+ },
{
- "@id": "http://qudt.org/vocab/unit/DEG_F"
+ "@id": "http://example.org/IBAL#VFD_2"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@value": "vav3 out rtd"
- }
- ]
- },
- {
- "@id": "http://example.org/IBAL#Channel_6",
- "@type": [
- "http://data.ashrae.org/standard223#HumiditySensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "@id": "http://example.org/IBAL#AHU_2_G_ICP"
+ },
{
- "@id": "http://example.org/IBAL#Segment_9"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
+ "@id": "http://example.org/IBAL#AHU_2_G_OCP"
+ },
{
- "@id": "http://example.org/IBAL#ahu1_rh_down"
+ "@id": "http://example.org/IBAL#AHU_2_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#AHU_2_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#AHU_2_S_ICP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 6"
+ "@value": "AHU 2"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_25",
+ "@id": "http://example.org/IBAL#Junction_10",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#Junction"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Damper_6_OCP"
+ "@id": "http://example.org/IBAL#Jnc10-ICP1"
},
{
- "@id": "http://example.org/IBAL#Jnc9-ICP"
+ "@id": "http://example.org/IBAL#Jnc10-ICP2"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc10-OCP"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -16117,44 +16058,28 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 25"
+ "@value": "Junction 10"
}
]
},
{
- "@id": "http://example.org/IBAL#ahu1_rh_down",
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_3_OCP",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasValue": [
- {
- "@type": "http://www.w3.org/2001/XMLSchema#decimal",
- "@value": "50"
- }
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
- {
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/value": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@value": "50"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "AHU 1 RH Down"
+ "@value": "Manual two way valve 3 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#HC_3_ICP",
+ "@id": "http://example.org/IBAL#Damper_13_ICP",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -16163,250 +16088,272 @@
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_13"
+ }
+ ],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "HC 3 ICP"
+ "@value": "Damper 13 ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_364AO",
+ "@id": "http://example.org/IBAL#Channel_88",
"@type": [
- "http://data.ashrae.org/standard223#Controller"
+ "http://data.ashrae.org/standard223#TemperatureSensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#MotorizedDamper_4"
+ "@id": "http://example.org/IBAL#VAV_2_Connection_2"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#d18_pos_c"
+ "@id": "http://example.org/IBAL#vav2_out_rtd"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 364AO"
+ "@value": "Channel 88"
}
]
},
{
- "@id": "http://example.org/IBAL#ahu1_p_down",
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_3_ICP_1",
"@type": [
- "http://data.ashrae.org/bacnet/2020#AnalogInputObject",
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/bacnet/2020#description": [
- {
- "@value": "Static Pressure Measurement Downstream Fan"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/bacnet/2020#object-identifier": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@value": "analog-input,3"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://data.ashrae.org/bacnet/2020#object-name": [
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
{
- "@value": "ahu1_p_down"
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_3"
}
],
- "http://data.ashrae.org/bacnet/2020#object-type": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "analog-input"
+ "@value": "Motorized three way valve 3 ICP 1"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#exf2_vfd",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/bacnet/2020#objectOf": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://example.org/IBAL#AHU_2"
+ "@id": "http://qudt.org/vocab/quantitykind/Voltage"
}
],
- "http://data.ashrae.org/bacnet/2020#present-value": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@type": "http://www.w3.org/2001/XMLSchema#float",
- "@value": "0.0"
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ "@value": "exf2 vfd"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc38-OCP2",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PA"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "AHU 1 P Down"
+ "@value": "Jnc38-OCP2"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_112",
+ "@id": "http://example.org/IBAL#Jnc20-OCP",
"@type": [
- "http://data.ashrae.org/standard223#TemperatureSensor"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#Segment_18"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://example.org/IBAL#zs4_out_rtd"
+ "@value": "Jnc20-OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc2-ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 112"
+ "@value": "Jnc2-ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_450",
+ "@id": "http://example.org/IBAL#Channel_384",
"@type": [
"http://data.ashrae.org/standard223#Controller"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#VFD_2"
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_2"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#ahu1_vfd"
+ "@id": "http://example.org/IBAL#v13_pos_fb"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 450"
+ "@value": "Channel 384"
}
]
},
{
- "@id": "http://example.org/IBAL#ManualTwoWayValve_2",
+ "@id": "http://example.org/IBAL#Channel_112",
"@type": [
- "http://data.ashrae.org/standard223#TwoWayValve"
+ "http://data.ashrae.org/standard223#TemperatureSensor"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#ManualTwoWayValve_2_ICP"
- },
+ "@id": "http://example.org/IBAL#Segment_18"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#ManualTwoWayValve_2_OCP"
+ "@id": "http://example.org/IBAL#zs4_out_rtd"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Manual two way valve 2"
+ "@value": "Channel 112"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_63",
+ "@id": "http://example.org/IBAL#oau_p_up",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#Jnc22-OCP1"
- },
+ "http://data.ashrae.org/standard223#hasValue": [
{
- "@id": "http://example.org/IBAL#PlateHeatExchange_1_Lower_ICP"
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "11297"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@value": "Segment 63"
+ "@id": "http://qudt.org/vocab/unit/PA"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#AHU_2_G_OCP",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/value": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@value": "11297"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "AHU 2 G OCP"
+ "@value": "oau p up"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_326",
+ "@id": "http://example.org/IBAL#Damper_3_ICP",
"@type": [
- "http://data.ashrae.org/standard223#FlowSensor"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#Segment_38"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://example.org/IBAL#ahu1_f_sa"
+ "@id": "http://example.org/IBAL#VAV_3_ICP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 326"
+ "@value": "Damper 3 ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_412",
+ "@id": "http://example.org/IBAL#HeatingCoil_5",
"@type": [
- "http://data.ashrae.org/standard223#Controller"
+ "http://data.ashrae.org/standard223#HeatingCoil"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_1"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
+ "@id": "http://example.org/IBAL#HC_5_E_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_5_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_5_OCP"
+ },
{
- "@id": "http://example.org/IBAL#v12_pos_c"
+ "@id": "http://example.org/IBAL#HC_5_W_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_5_W_OCP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 412"
+ "@value": "Heating coil 5"
}
]
},
{
- "@id": "http://example.org/IBAL#MotorizedDamper_13",
+ "@id": "http://example.org/IBAL#WaterPump_2",
"@type": [
- "http://data.ashrae.org/standard223#Damper"
+ "http://data.ashrae.org/standard223#Pump"
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://example.org/IBAL#Damper_13_ICP"
+ "@id": "http://example.org/IBAL#WaterPump_2_ICP"
},
{
- "@id": "http://example.org/IBAL#Damper_13_OCP"
+ "@id": "http://example.org/IBAL#WaterPump_2_OCP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Motorized damper 13"
+ "@value": "Water pump 2"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc17-ICP",
+ "@id": "http://example.org/IBAL#Damper_1_ICP",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -16415,711 +16362,768 @@
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "http://example.org/IBAL#VAV_1_ICP"
+ }
+ ],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc17-ICP"
+ "@value": "Damper 1 ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#HVAC_Space_2_ICP",
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_5_OCP",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_5"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "HVAC Space 2 ICP"
+ "@value": "Motorized three way valve 5 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Fan_5",
+ "@id": "http://example.org/IBAL#vav4_f",
"@type": [
- "http://data.ashrae.org/standard223#Fan"
+ "http://data.ashrae.org/bacnet/2020#AnalogInputObject",
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "http://example.org/IBAL#Fan_5_E_ICP"
- },
- {
- "@id": "http://example.org/IBAL#Fan_5_ICP"
- },
+ "http://data.ashrae.org/bacnet/2020#description": [
{
- "@id": "http://example.org/IBAL#Fan_5_OCP"
+ "@value": "VAV4 Airflow Rate"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/bacnet/2020#object-identifier": [
{
- "@value": "Fan 5"
+ "@value": "analog-input,4"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#Channel_329",
- "@type": [
- "http://data.ashrae.org/standard223#Controller"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/bacnet/2020#object-name": [
{
- "@id": "http://example.org/IBAL#MotorizedDamper_13"
+ "@value": "vav4_f"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/bacnet/2020#object-type": [
{
- "@id": "http://example.org/IBAL#d6_pos_fb"
+ "@value": "analog-input"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/bacnet/2020#objectOf": [
{
- "@value": "Channel 329"
+ "@id": "http://example.org/IBAL#VAV_4"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#Segment_86",
- "@type": [
- "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/bacnet/2020#present-value": [
{
- "@id": "http://example.org/IBAL#Jnc27-OCP2"
- },
+ "@type": "http://www.w3.org/2001/XMLSchema#float",
+ "@value": "0.0"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://example.org/IBAL#ManualTwoWayValve_5_ICP"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 86"
+ "@value": "vav4 f"
}
]
},
{
- "@id": "http://example.org/IBAL#Junction_35",
+ "@id": "http://example.org/IBAL#ReturnAir-1-Flow",
"@type": [
- "http://data.ashrae.org/standard223#Junction"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasValue": [
{
- "@id": "http://example.org/IBAL#Jnc35-ICP1"
- },
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "500"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://example.org/IBAL#Jnc35-ICP2"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://example.org/IBAL#Jnc35-OCP"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/value": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@value": "500"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Junction 35"
+ "@value": "Return Air 1 Flow"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_98",
+ "@id": "http://example.org/IBAL#Jnc27-OCP1",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#Jnc22-ICP"
- },
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://example.org/IBAL#Jnc36-OCP2"
+ "@value": "Jnc27-OCP1"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc7-ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 98"
+ "@value": "Jnc7-ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc22-OCP2",
+ "@id": "http://example.org/IBAL#HC_6_W_OCP",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc22-OCP2"
+ "@value": "HC 6 W OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#MotorizedDamper_15",
+ "@id": "http://example.org/IBAL#Jnc34-OCP2",
"@type": [
- "http://data.ashrae.org/standard223#Damper"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "http://example.org/IBAL#Damper_15_ICP"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#Damper_15_OCP"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Motorized damper 15"
+ "@value": "Jnc34-OCP2"
}
]
},
{
- "@id": "http://example.org/IBAL#zs2_heat_rtd",
+ "@id": "http://example.org/IBAL#exf1_f",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasValue": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@type": "http://www.w3.org/2001/XMLSchema#decimal",
- "@value": "70"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_F"
+ "@value": "exf1 f"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Chiller_2_Upper_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/value": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@value": "70"
+ "@id": "http://data.ashrae.org/standard223#Water-ChilledWater"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "zs2 heat rtd"
+ "@value": "Chiller 2 Upper OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_104",
+ "@id": "http://example.org/IBAL#Segment_60",
"@type": [
"http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/standard223#connectsAt": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_5_ICP_1"
+ "@id": "http://example.org/IBAL#Jnc20-ICP"
},
{
- "@id": "http://example.org/IBAL#ThermalStorage_1_OCP"
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_2_OCP"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-ChilledWater"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 104"
+ "@value": "Segment 60"
}
]
},
{
- "@id": "http://example.org/IBAL#HC_1_W_OCP",
+ "@id": "http://example.org/IBAL#VFD_1_ICP",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "HC 1 W OCP"
+ "@value": "VFD 1 ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#vav4_f",
+ "@id": "http://example.org/IBAL#HC_1_W_ICP",
"@type": [
- "http://data.ashrae.org/bacnet/2020#AnalogInputObject",
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/bacnet/2020#description": [
- {
- "@value": "VAV4 Airflow Rate"
- }
- ],
- "http://data.ashrae.org/bacnet/2020#object-identifier": [
- {
- "@value": "analog-input,4"
- }
- ],
- "http://data.ashrae.org/bacnet/2020#object-name": [
- {
- "@value": "vav4_f"
- }
- ],
- "http://data.ashrae.org/bacnet/2020#object-type": [
- {
- "@value": "analog-input"
- }
- ],
- "http://data.ashrae.org/bacnet/2020#objectOf": [
- {
- "@id": "http://example.org/IBAL#VAV_4"
- }
- ],
- "http://data.ashrae.org/bacnet/2020#present-value": [
- {
- "@type": "http://www.w3.org/2001/XMLSchema#float",
- "@value": "0.0"
- }
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "vav4 f"
+ "@value": "HC 1 W ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#HC_6_E_ICP",
+ "@id": "http://example.org/IBAL#Jnc7-OCP2",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "HC 6 E ICP"
+ "@value": "Jnc7-OCP2"
}
]
},
{
- "@id": "http://example.org/IBAL#Damper_8_ICP",
+ "@id": "http://example.org/IBAL#Jnc31-ICP2",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://data.ashrae.org/standard223#isConnectionPointOf": [
- {
- "@id": "http://example.org/IBAL#MotorizedDamper_8"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Damper 8 ICP"
+ "@value": "Jnc31-ICP2"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_84",
+ "@id": "http://example.org/IBAL#Channel_308",
"@type": [
- "http://data.ashrae.org/standard223#TemperatureSensor"
+ "http://data.ashrae.org/standard223#FlowSensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#AHU_3_Connection_2"
+ "@id": "http://example.org/IBAL#Segment_10"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#oau_cc_rtd"
+ "@id": "http://example.org/IBAL#vav4_f"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 84"
+ "@value": "Channel 308"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_33",
+ "@id": "http://example.org/IBAL#Enclosure_3",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://example.org/IBAL#Damper_9_OCP"
- },
+ "@id": "http://example.org/IBAL#HVACSpace_3"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://example.org/IBAL#Jnc11-ICP1"
+ "@value": "Enclosure 3"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc18-OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 33"
+ "@value": "Jnc18-OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_4",
+ "@id": "http://example.org/IBAL#Channel_394bw",
"@type": [
- "http://data.ashrae.org/standard223#PressureSensor"
+ "http://data.ashrae.org/standard223#Controller"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#AHU_2_Connection_3"
+ "@id": "http://example.org/IBAL#Fan_4"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#ahu1_p_up"
+ "@id": "http://example.org/IBAL#exf2_on"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 4"
+ "@value": "Channel 394bw"
}
]
},
{
- "@id": "http://example.org/IBAL#Junction_26",
+ "@id": "http://example.org/IBAL#vav2_t_in",
"@type": [
- "http://data.ashrae.org/standard223#Junction"
+ "http://data.ashrae.org/bacnet/2020#AnalogInputObject",
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/bacnet/2020#description": [
{
- "@id": "http://example.org/IBAL#Jnc26-ICP1"
- },
+ "@value": "VAV2 Supply Air Temperature"
+ }
+ ],
+ "http://data.ashrae.org/bacnet/2020#object-identifier": [
{
- "@id": "http://example.org/IBAL#Jnc26-ICP2"
- },
+ "@value": "analog-input,3"
+ }
+ ],
+ "http://data.ashrae.org/bacnet/2020#object-name": [
{
- "@id": "http://example.org/IBAL#Jnc26-OCP"
+ "@value": "vav2_t_in"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/bacnet/2020#object-type": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@value": "analog-input"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/bacnet/2020#objectOf": [
{
- "@value": "Junction 26"
+ "@id": "http://example.org/IBAL#VAV_2"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#Segment_101",
- "@type": [
- "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/bacnet/2020#present-value": [
{
- "@id": "http://example.org/IBAL#Jnc18-ICP"
- },
+ "@type": "http://www.w3.org/2001/XMLSchema#float",
+ "@value": "70.0"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://example.org/IBAL#Jnc38-OCP"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 101"
+ "@value": "vav2 t in"
}
]
},
{
- "@id": "http://example.org/IBAL#VFD_4_OCP",
+ "@id": "http://example.org/IBAL#Channel_310AO",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Controller"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
+ "@id": "http://example.org/IBAL#MotorizedDamper_14"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#d5_pos_c"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "VFD 4 OCP"
+ "@value": "Channel 310AO"
}
]
},
{
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_5",
+ "@id": "http://example.org/IBAL#VAV_2",
"@type": [
- "http://data.ashrae.org/standard223#ThreeWayValve"
+ "http://data.ashrae.org/bacnet/2020#BACnetDevice",
+ "http://data.ashrae.org/standard223#TerminalUnit"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/bacnet/2020#hasPort": [
{
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_5_ICP_1"
+ "@id": "http://data.ashrae.org/bacnet/2020#P_47812"
+ }
+ ],
+ "http://data.ashrae.org/standard223#contains": [
+ {
+ "@id": "http://example.org/IBAL#HeatingCoil_3"
},
{
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_5_ICP_2"
+ "@id": "http://example.org/IBAL#MotorizedDamper_2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#VAV_2_ICP"
},
{
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_5_OCP"
+ "@id": "http://example.org/IBAL#VAV_2_OCP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Motorized three way valve 5"
+ "@value": "VAV 2"
}
]
},
{
- "@id": "http://example.org/IBAL#oau_cc_rtd",
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_5_ICP",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasValue": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@type": "http://www.w3.org/2001/XMLSchema#decimal",
- "@value": "45"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@value": "Manual two way valve 5 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HVACSpace_4",
+ "@type": [
+ "http://data.ashrae.org/standard223#DomainSpace"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#HVAC_Space_4_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HVAC_Space_4_OCP"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_F"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "http://example.org/IBAL#zs4_t_sp_f"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "oau cc rtd"
+ "@value": "HVACSpace 4"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc23-ICP2",
+ "@id": "http://example.org/IBAL#zs4_t_sp_f",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/bacnet/2020#AnalogInputObject",
+ "http://data.ashrae.org/standard223#QuantifiableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/bacnet/2020#description": [
{
- "@id": "http://example.org/IBAL#Segment_107"
+ "@value": "Zone4 Temperature Setpoint"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/bacnet/2020#object-identifier": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@value": "analog-input,6"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/bacnet/2020#object-name": [
{
- "@value": "Jnc23-ICP2"
+ "@value": "zs4_t_sp_f"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#ManualTwoWayValve_5_ICP",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/bacnet/2020#object-type": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@value": "analog-input"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/bacnet/2020#objectOf": [
{
- "@value": "Manual two way valve 5 ICP"
+ "@id": "http://example.org/IBAL#VAV_4"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#Jnc16-ICP",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/bacnet/2020#present-value": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@type": "http://www.w3.org/2001/XMLSchema#float",
+ "@value": "74.0"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasAspect": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Aspect-Setpoint"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc16-ICP"
+ "@value": "zs4 t sp f"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc29-OCP",
+ "@id": "http://example.org/IBAL#Damper_2_OCP",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc29-OCP"
+ "@value": "Damper 2 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#VFD_3_ICP",
+ "@id": "http://example.org/IBAL#Segment_52",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Connection"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#lnx": [
+ {
+ "@id": "http://example.org/IBAL#AHU_3_ICP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "VFD 3 ICP"
+ "@value": "Segment 52"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc9-OCP",
+ "@id": "http://example.org/IBAL#exf2_p_down",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PA"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc9-OCP"
+ "@value": "exf2 p down"
}
]
},
{
- "@id": "http://example.org/IBAL#pl_f",
+ "@id": "http://example.org/IBAL#d17_pos_fb",
"@type": [
+ "http://data.ashrae.org/bacnet/2020#AnalogInputObject",
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
+ "http://data.ashrae.org/bacnet/2020#description": [
+ {
+ "@value": "VAV3 Damper Feedback Signal"
+ }
+ ],
+ "http://data.ashrae.org/bacnet/2020#object-identifier": [
+ {
+ "@value": "analog-input,1"
+ }
+ ],
+ "http://data.ashrae.org/bacnet/2020#object-name": [
+ {
+ "@value": "d17_pos_fb"
+ }
+ ],
+ "http://data.ashrae.org/bacnet/2020#object-type": [
+ {
+ "@value": "analog-input"
+ }
+ ],
+ "http://data.ashrae.org/bacnet/2020#objectOf": [
+ {
+ "@id": "http://example.org/IBAL#VAV_3"
+ }
+ ],
+ "http://data.ashrae.org/bacnet/2020#present-value": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#float",
+ "@value": "0.0"
+ }
+ ],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/Voltage"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/GAL_US-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "pl f"
+ "@value": "d17 pos fb"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_336AO",
+ "@id": "http://example.org/IBAL#Channel_402",
"@type": [
"http://data.ashrae.org/standard223#Controller"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#VAV_1"
+ "@id": "http://example.org/IBAL#HeatingCoil_3"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#d15_pos_c"
+ "@id": "http://example.org/IBAL#vav2_heat_c"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 336AO"
+ "@value": "Channel 402"
}
]
},
{
- "@id": "http://example.org/IBAL#ahu1_p_up",
+ "@id": "http://example.org/IBAL#Chiller_1_Upper_ICP",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasValue": [
- {
- "@type": "http://www.w3.org/2001/XMLSchema#decimal",
- "@value": "11296"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://qudt.org/vocab/unit/PA"
+ "@value": "Chiller 1 Upper ICP"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_17",
+ "@type": [
+ "http://data.ashrae.org/standard223#Damper"
],
- "http://qudt.org/schema/qudt/value": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@value": "11296"
+ "@id": "http://example.org/IBAL#Damper_17_ICP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "AHU1 P Up"
+ "@value": "Motorized damper 17"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_6",
+ "@id": "http://example.org/IBAL#HVAC_Space_4_OCP",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Damper_5_OCP"
- },
- {
- "@id": "http://example.org/IBAL#Jnc3-ICP1"
+ "@id": "http://example.org/IBAL#Segment_18"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -17129,159 +17133,140 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 6"
+ "@value": "HVAC Space 4 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_26",
+ "@id": "http://example.org/IBAL#Flow_6",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#FlowSensor"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#Damper_10_ICP"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#Jnc9-OCP"
+ "@id": "http://example.org/IBAL#VAV_2_Connection_2"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://example.org/IBAL#HC-3-OutletFlow"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 26"
+ "@value": "Flow 6"
}
]
},
{
- "@id": "http://example.org/IBAL#vav3_heat_power",
+ "@id": "http://example.org/IBAL#Damper_7_OCP",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
{
- "@id": "http://qudt.org/vocab/unit/W"
+ "@id": "http://example.org/IBAL#MotorizedDamper_7"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "vav3 heat power"
+ "@value": "Damper 7 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Junction_31",
+ "@id": "http://example.org/IBAL#ahu1_f_ra",
"@type": [
- "http://data.ashrae.org/standard223#Junction"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#Jnc31-ICP1"
- },
- {
- "@id": "http://example.org/IBAL#Jnc31-ICP2"
- },
+ "http://data.ashrae.org/standard223#hasValue": [
{
- "@id": "http://example.org/IBAL#Jnc31-OCP"
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "1000"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@value": "Junction 31"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#Jnc12-ICP",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/value": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@value": "1000"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc12-ICP"
+ "@value": "AHU 1 F RA"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_325T",
+ "@id": "http://example.org/IBAL#VAV_2_Connection_2",
"@type": [
- "http://data.ashrae.org/standard223#TemperatureSensor"
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Segment_23"
+ "@id": "http://example.org/IBAL#HVAC_Space_2_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#VAV_2_OCP"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#ahu1_t_ra"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 325T"
+ "@value": "VAV 2 Connection 2"
}
]
},
{
- "@id": "http://example.org/IBAL#HVACSpace_4",
+ "@id": "http://example.org/IBAL#ahu2_f_ra",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "http://example.org/IBAL#HVAC_Space_4_ICP"
- },
- {
- "@id": "http://example.org/IBAL#HVAC_Space_4_OCP"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://example.org/IBAL#zs4_t_sp_f"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "HVACSpace 4"
+ "@value": "ahu2 f ra"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_61",
+ "@id": "http://example.org/IBAL#Segment_69",
"@type": [
"http://data.ashrae.org/standard223#Connection"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Jnc20-OCP"
+ "@id": "http://example.org/IBAL#Jnc25-ICP"
},
{
- "@id": "http://example.org/IBAL#Jnc21-ICP1"
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_4_OCP"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -17291,37 +17276,45 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 61"
+ "@value": "Segment 69"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc2-OCP2",
+ "@id": "http://example.org/IBAL#Segment_83",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc31-ICP2"
+ },
+ {
+ "@id": "http://example.org/IBAL#WaterPump_2_OCP"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc2-OCP2"
+ "@value": "Segment 83"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_71",
+ "@id": "http://example.org/IBAL#Segment_74",
"@type": [
"http://data.ashrae.org/standard223#Connection"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Jnc25-OCP2"
+ "@id": "http://example.org/IBAL#Jnc27-OCP1"
},
{
- "@id": "http://example.org/IBAL#Jnc26-ICP1"
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_4_ICP"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -17331,133 +17324,114 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 71"
+ "@value": "Segment 74"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_302T",
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_4",
"@type": [
- "http://data.ashrae.org/standard223#TemperatureSensor"
+ "http://data.ashrae.org/standard223#TwoWayValve"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://example.org/IBAL#Segment_4"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_4_ICP"
+ },
{
- "@id": "http://example.org/IBAL#vav2_t_in"
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_4_OCP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 302T"
+ "@value": "Manual two way valve 4"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc26-ICP1",
+ "@id": "http://example.org/IBAL#Channel_495",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Controller"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://example.org/IBAL#MotorizedDamper_8"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#d10_pos_fb"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc26-ICP1"
+ "@value": "Channel 495"
}
]
},
{
- "@id": "http://example.org/IBAL#Fan_5_ICP",
+ "@id": "http://example.org/IBAL#ahu2_out_rtd",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/bacnet/2020#AnalogInputObject",
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/bacnet/2020#description": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@value": "AHU2 Supply Air Temperature"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/bacnet/2020#object-identifier": [
{
- "@value": "Fan 5 ICP"
+ "@value": "analog-input,2"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#CC_1_ICP",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/bacnet/2020#object-name": [
{
- "@id": "http://example.org/IBAL#CoolingCoil_1"
+ "@value": "ahu2_out_rtd"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/bacnet/2020#object-type": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@value": "analog-input"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/bacnet/2020#objectOf": [
{
- "@value": "CC 1 ICP"
+ "@id": "http://example.org/IBAL#AHU_1"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#WaterPump_2",
- "@type": [
- "http://data.ashrae.org/standard223#Pump"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "http://example.org/IBAL#WaterPump_2_ICP"
- },
+ "http://data.ashrae.org/bacnet/2020#present-value": [
{
- "@id": "http://example.org/IBAL#WaterPump_2_OCP"
+ "@type": "http://www.w3.org/2001/XMLSchema#float",
+ "@value": "70.0"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@value": "Water pump 2"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
- ]
- },
- {
- "@id": "http://example.org/IBAL#HC_2_E_ICP",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "HC 2 E ICP"
+ "@value": "ahu2 out rtd"
}
]
},
{
- "@id": "http://example.org/IBAL#Junction_7",
+ "@id": "http://example.org/IBAL#AHU_3_Connection_3",
"@type": [
- "http://data.ashrae.org/standard223#Junction"
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#Jnc7-ICP"
- },
+ "http://data.ashrae.org/standard223#connectsAt": [
{
- "@id": "http://example.org/IBAL#Jnc7-OCP1"
+ "@id": "http://example.org/IBAL#Fan_5_ICP"
},
{
- "@id": "http://example.org/IBAL#Jnc7-OCP2"
+ "@id": "http://example.org/IBAL#HC_7_OCP"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -17467,189 +17441,176 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Junction 7"
+ "@value": "AHU 3 Connection 3"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc2-OCP1",
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_2",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#ThreeWayValve"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_2_ICP_1"
+ },
{
- "@id": "http://example.org/IBAL#Junction_2"
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_2_ICP_2"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_2_OCP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc2-OCP1"
+ "@value": "Motorized three way valve 2"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_404",
+ "@id": "http://example.org/IBAL#Segment_33",
"@type": [
- "http://data.ashrae.org/standard223#Controller"
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#HeatingCoil_6"
+ "@id": "http://example.org/IBAL#Damper_9_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc11-ICP1"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#vav4_heat_c"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 404"
+ "@value": "Segment 33"
}
]
},
{
- "@id": "http://example.org/IBAL#Damper_14_ICP",
+ "@id": "http://example.org/IBAL#Segment_93",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://example.org/IBAL#Jnc34-OCP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc35-ICP2"
}
],
- "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#MotorizedDamper_14"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Damper 14 ICP"
+ "@value": "Segment 93"
}
]
},
{
- "@id": "http://example.org/IBAL#CC_2_OCP",
+ "@id": "http://example.org/IBAL#Channel_327",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#FlowSensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://example.org/IBAL#Segment_39"
}
],
- "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#CoolingCoil_2"
+ "@id": "http://example.org/IBAL#ahu2_f_sa"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": " CC 2 OCP"
+ "@value": "Channel 327"
}
]
},
{
- "@id": "http://example.org/IBAL#HC_5_OCP",
+ "@id": "http://example.org/IBAL#Jnc19-OCP2",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "http://example.org/IBAL#VAV_3_OCP"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "HC 5 OCP"
+ "@value": "Jnc19-OCP2"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_110",
+ "@id": "http://example.org/IBAL#Jnc3-ICP2",
"@type": [
- "http://data.ashrae.org/standard223#TemperatureSensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "http://example.org/IBAL#Segment_16"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#zs3_out_rtd"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 110"
+ "@value": "Jnc3-ICP2"
}
]
},
{
- "@id": "http://example.org/IBAL#ahu1_cc_out_rtd",
+ "@id": "http://example.org/IBAL#Enclosure_1",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_F"
+ "@id": "http://example.org/IBAL#HVACSpace_1"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "AHU1 CC Out RTD"
+ "@value": "Enclosure 1"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_13",
+ "@id": "http://example.org/IBAL#VFD_3_OCP",
"@type": [
- "http://data.ashrae.org/standard223#PressureSensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "http://example.org/IBAL#Segment_27"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#exf1_p_up"
+ "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 13"
+ "@value": "VFD 3 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_2",
+ "@id": "http://example.org/IBAL#VAV_3_Connection_1",
"@type": [
"http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#connectsAt": [
{
- "@id": "http://example.org/IBAL#Jnc1-OCP2"
+ "@id": "http://example.org/IBAL#Damper_3_OCP"
},
{
- "@id": "http://example.org/IBAL#VAV_1_ICP"
+ "@id": "http://example.org/IBAL#HC_5_ICP"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -17659,21 +17620,18 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 2"
+ "@value": "VAV 3 Connection 1"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_43",
+ "@id": "http://example.org/IBAL#CC_1_OCP",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Damper_15_OCP"
- },
- {
- "@id": "http://example.org/IBAL#Jnc12-ICP"
+ "@id": "http://example.org/IBAL#CoolingCoil_1"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -17683,121 +17641,196 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 43"
+ "@value": " CC 1 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_74",
+ "@id": "http://example.org/IBAL#PlateHetExchange_1_Bypass_Connection",
"@type": [
- "http://data.ashrae.org/standard223#TemperatureSensor"
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#connectsAt": [
{
- "@id": "http://example.org/IBAL#AHU_2_Connection_2"
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_3_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_3_ICP_2"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#ahu1_heat_rtd"
+ "@id": "http://data.ashrae.org/standard223#Water-ChilledWater"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 74"
+ "@value": "Plate Heat Exchange 1 Bypass Connection"
}
]
},
{
- "@id": "http://example.org/IBAL#WaterPump_3",
+ "@id": "http://example.org/IBAL#Jnc6-ICP2",
"@type": [
- "http://data.ashrae.org/standard223#Pump"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "http://example.org/IBAL#WaterPump_3_ICP"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#WaterPump_3_OCP"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Water pump 3"
+ "@value": "Jnc6-ICP2"
}
]
},
{
- "@id": "http://example.org/IBAL#ahu1_t_ra",
+ "@id": "http://example.org/IBAL#AirFlow",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#System"
],
- "http://data.ashrae.org/standard223#hasValue": [
+ "http://data.ashrae.org/standard223#hasMember": [
{
- "@type": "http://www.w3.org/2001/XMLSchema#decimal",
- "@value": "65"
- }
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "@id": "http://example.org/IBAL#AHU_1"
+ },
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "http://example.org/IBAL#AHU_2"
+ },
{
- "@id": "http://qudt.org/vocab/unit/DEG_F"
+ "@id": "http://example.org/IBAL#Fan_3"
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_4"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_10"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_11"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_12"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_13"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_14"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_15"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_16"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_17"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_18"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_19"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_5"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_6"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_7"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_8"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_9"
+ },
+ {
+ "@id": "http://example.org/IBAL#VAV_1"
+ },
+ {
+ "@id": "http://example.org/IBAL#VAV_2"
+ },
+ {
+ "@id": "http://example.org/IBAL#VAV_3"
+ },
+ {
+ "@id": "http://example.org/IBAL#VAV_4"
+ },
+ {
+ "@id": "http://example.org/IBAL#VFD_3"
+ },
+ {
+ "@id": "http://example.org/IBAL#VFD_4"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "AHU 1 T RA"
+ "@value": "AirFlow"
}
]
},
{
- "@id": "http://example.org/IBAL#sl_out_rtd",
+ "@id": "http://example.org/IBAL#MotorizedDamper_7",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Damper"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://example.org/IBAL#Damper_7_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_7_OCP"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_F"
+ "@value": "Motorized damper 7"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#AHU_2_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/value": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@value": "64"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "sl out rtd"
+ "@value": "AHU 2 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc27-ICP",
+ "@id": "http://example.org/IBAL#Channel_16",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#PressureSensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://example.org/IBAL#Segment_30"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#exf2_p_up"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc27-ICP"
+ "@value": "Channel 16"
}
]
},
{
- "@id": "http://example.org/IBAL#AHU_1_ICP",
+ "@id": "http://example.org/IBAL#Damper_6_ICP",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -17806,75 +17839,85 @@
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_6"
+ }
+ ],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "AHU 1 ICP"
+ "@value": "Damper 6 ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#exf1_power",
+ "@id": "http://example.org/IBAL#ahu1_heat_rtd",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Power"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/W"
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "exf1 power"
+ "@value": "AHU 1 Heat RTD"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_401",
+ "@id": "http://example.org/IBAL#Segment_47",
"@type": [
- "http://data.ashrae.org/standard223#Controller"
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#HeatingCoil_2"
+ "@id": "http://example.org/IBAL#Damper_16_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc16-ICP"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#vav1_heat_c"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 401"
+ "@value": "Segment 47"
}
]
},
{
- "@id": "http://example.org/IBAL#VFD_1",
+ "@id": "http://example.org/IBAL#Jnc23-ICP",
"@type": [
- "http://data.ashrae.org/standard223#VariableFrequencyDrive"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#VFD_1_ICP"
- },
+ "@id": "http://example.org/IBAL#Segment_62"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#VFD_1_OCP"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "VFD 1"
+ "@value": "Jnc23-ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#ts_in_rtd",
+ "@id": "http://example.org/IBAL#ahu1_cc_out_rtd",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -17890,202 +17933,218 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "ts in rtd"
+ "@value": "AHU1 CC Out RTD"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc18-OCP2",
+ "@id": "http://example.org/IBAL#WaterPump_4_OCP",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc18-OCP2"
+ "@value": "Water pump 4 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Damper_7_OCP",
+ "@id": "http://example.org/IBAL#ahu2_p_up",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
}
],
- "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PA"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "ahu2 p up"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#VFD_2",
+ "@type": [
+ "http://data.ashrae.org/standard223#VariableFrequencyDrive"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#VFD_2_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#VFD_2_OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://example.org/IBAL#MotorizedDamper_7"
+ "@id": "http://example.org/IBAL#ahu1_vfd"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Damper 7 OCP"
+ "@value": "VFD 2"
}
]
},
{
- "@id": "http://example.org/IBAL#exf2_vfd",
+ "@id": "http://example.org/IBAL#Channel_127",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#TemperatureSensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Voltage"
+ "@id": "http://example.org/IBAL#Segment_104"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "http://example.org/IBAL#ts_out_rtd"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "exf2 vfd"
+ "@value": "Channel 127"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_84",
+ "@id": "http://example.org/IBAL#HC_4_W_ICP",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#Jnc30-OCP"
- },
- {
- "@id": "http://example.org/IBAL#Jnc31-ICP1"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 84"
+ "@value": "HC 4 W ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#VAV_3_Connection_1",
+ "@id": "http://example.org/IBAL#AHU_1_G_ICP",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
- ],
- "http://data.ashrae.org/standard223#connectsAt": [
- {
- "@id": "http://example.org/IBAL#Damper_3_OCP"
- },
- {
- "@id": "http://example.org/IBAL#HC_5_ICP"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "VAV 3 Connection 1"
+ "@value": "AHU 1 G ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#ahu1_t_sa",
+ "@id": "http://example.org/IBAL#exf1_on",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasValue": [
- {
- "@type": "http://www.w3.org/2001/XMLSchema#decimal",
- "@value": "60"
- }
- ],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Voltage"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_F"
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "AHU 1 T SA"
+ "@value": "exf1 on"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_3",
+ "@id": "http://example.org/IBAL#Junction_1",
"@type": [
- "http://data.ashrae.org/standard223#HumiditySensor"
+ "http://data.ashrae.org/standard223#Junction"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#HC_4_ICP"
+ "@id": "http://example.org/IBAL#Jnc1-ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc1-OCP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc1-OCP2"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#ahu1_rh_up"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 3"
+ "@value": "Junction 1"
}
]
},
{
- "@id": "http://example.org/IBAL#Fan_5_VFD_5",
+ "@id": "http://example.org/IBAL#VFD_2_OCP",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#Fan_5_E_ICP"
- },
+ "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://example.org/IBAL#VFD_5_OCP"
+ "@value": "VFD 2 OCP"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc19-OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Fan 5 VFD 5"
+ "@value": "Jnc19-OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Junction_25",
+ "@id": "http://example.org/IBAL#Junction_37",
"@type": [
"http://data.ashrae.org/standard223#Junction"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Jnc25-ICP"
+ "@id": "http://example.org/IBAL#Jnc37-ICP"
},
{
- "@id": "http://example.org/IBAL#Jnc25-OCP1"
+ "@id": "http://example.org/IBAL#Jnc37-OCP1"
},
{
- "@id": "http://example.org/IBAL#Jnc25-OCP2"
+ "@id": "http://example.org/IBAL#Jnc37-OCP2"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -18095,42 +18154,39 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Junction 25"
+ "@value": "Junction 37"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_37",
+ "@id": "http://example.org/IBAL#v8_pos_fb",
"@type": [
- "http://data.ashrae.org/standard223#HumiditySensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://example.org/IBAL#Segment_12"
+ "@id": "http://qudt.org/vocab/quantitykind/Voltage"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://example.org/IBAL#zs1_rh"
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 37"
+ "@value": "v8 pos fb"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_75",
+ "@id": "http://example.org/IBAL#Jnc37-ICP",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Jnc26-ICP2"
- },
- {
- "@id": "http://example.org/IBAL#ManualTwoWayValve_4_OCP"
+ "@id": "http://example.org/IBAL#Segment_99"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -18140,439 +18196,343 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 75"
+ "@value": "Jnc37-ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#MotorizedDamper_1",
+ "@id": "http://example.org/IBAL#WaterPump_4",
"@type": [
- "http://data.ashrae.org/standard223#Damper"
+ "http://data.ashrae.org/standard223#Pump"
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://example.org/IBAL#Damper_1_ICP"
+ "@id": "http://example.org/IBAL#WaterPump_4_ICP"
},
{
- "@id": "http://example.org/IBAL#Damper_1_OCP"
+ "@id": "http://example.org/IBAL#WaterPump_4_OCP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Motorized damper 1"
+ "@value": "Water pump 4"
}
]
},
{
- "@id": "http://example.org/IBAL#HC-5-OutletFlow",
+ "@id": "http://example.org/IBAL#Channel_64",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasValue": [
- {
- "@type": "http://www.w3.org/2001/XMLSchema#decimal",
- "@value": "20"
- }
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
- }
+ "http://data.ashrae.org/standard223#ElectricMeter"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://example.org/IBAL#HeatingCoil_3"
}
],
- "http://qudt.org/schema/qudt/value": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@value": "20"
+ "@id": "http://example.org/IBAL#vav2_heat_power"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "HC 5 OutletFlow"
+ "@value": "Channel 64"
}
]
},
{
- "@id": "http://example.org/IBAL#CC_1_Water_ICP",
+ "@id": "http://example.org/IBAL#Damper_9_ICP",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "http://example.org/IBAL#AHU_1_G_ICP"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "CC 1 Water ICP"
- }
- ]
- },
- {
- "@id": "http://example.org/IBAL#hx1_pg_rtd",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
- {
- "@id": "http://qudt.org/vocab/unit/DEG_F"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://qudt.org/schema/qudt/value": [
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
{
- "@value": "70"
+ "@id": "http://example.org/IBAL#MotorizedDamper_9"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "hx1_hw_rtd"
+ "@value": "Damper 9 ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#HVAC_Space_1_ICP",
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_2_ICP",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "HVAC Space 1 ICP"
+ "@value": "Manual two way valve 2 ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_125",
+ "@id": "http://example.org/IBAL#Channel_76",
"@type": [
"http://data.ashrae.org/standard223#TemperatureSensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#Segment_106"
+ "@id": "http://example.org/IBAL#Segment_9"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#ahu2_cc_out_rtd"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "Channel 125"
- }
- ]
- },
- {
- "@id": "http://example.org/IBAL#Jnc16-OCP1",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://example.org/IBAL#ahu1_out_rtd"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc16-OCP1"
+ "@value": "Channel 76"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_19",
- "@type": [
- "http://data.ashrae.org/standard223#Connection"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#Jnc5-OCP"
- },
- {
- "@id": "http://example.org/IBAL#Jnc7-ICP"
- }
+ "@id": "http://example.org/IBAL#Jnc30-ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 19"
+ "@value": "Jnc30-ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#ManualTwoWayValve_4",
+ "@id": "http://example.org/IBAL#ThermalStorage_1",
"@type": [
- "http://data.ashrae.org/standard223#TwoWayValve"
+ "http://data.ashrae.org/standard223#Equipment"
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://example.org/IBAL#ManualTwoWayValve_4_ICP"
+ "@id": "http://example.org/IBAL#ThermalStorage_1_ICP"
},
{
- "@id": "http://example.org/IBAL#ManualTwoWayValve_4_OCP"
+ "@id": "http://example.org/IBAL#ThermalStorage_1_OCP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Manual two way valve 4"
+ "@value": "ThermalStorage 1"
}
]
},
{
- "@id": "http://example.org/IBAL#Damper_8_OCP",
+ "@id": "http://example.org/IBAL#Segment_87",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://example.org/IBAL#Jnc32-ICP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_5_OCP"
}
],
- "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#MotorizedDamper_8"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Damper 8 OCP"
+ "@value": "Segment 87"
}
]
},
{
- "@id": "http://example.org/IBAL#MotorizedThreeWayValve_1_OCP",
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_4",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#ThreeWayValve"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_4_ICP_1"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_4_ICP_2"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_4_OCP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Motorized three way valve 1 OCP"
+ "@value": "Motorized three way valve 4"
}
]
},
{
- "@id": "http://example.org/IBAL#Damper_5_OCP",
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_4_ICP_2",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://data.ashrae.org/standard223#isConnectionPointOf": [
- {
- "@id": "http://example.org/IBAL#MotorizedDamper_5"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Damper 5 OCP"
+ "@value": "Motorized three way valve 4 ICP 2"
}
]
},
{
- "@id": "http://example.org/IBAL#vav4_heat_power",
+ "@id": "http://example.org/IBAL#ch2_e_out_rtd",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/W"
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "vav4 heat power"
+ "@value": "ch2 e out rtd"
}
]
},
{
- "@id": "http://example.org/IBAL#HVACSpace_2",
+ "@id": "http://example.org/IBAL#ahu1_rh_up",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/standard223#hasValue": [
{
- "@id": "http://example.org/IBAL#HVAC_Space_2_ICP"
- },
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "60"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://example.org/IBAL#HVAC_Space_2_OCP"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://qudt.org/schema/qudt/value": [
{
- "@id": "http://example.org/IBAL#zs2_t_sp_f"
+ "@value": "60"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "HVACSpace 2"
+ "@value": "AHU 1 RH Up"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_155",
+ "@id": "http://example.org/IBAL#Jnc22-ICP",
"@type": [
- "http://data.ashrae.org/standard223#TemperatureSensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "http://example.org/IBAL#Segment_56"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#ahu2_cc_in_rtd"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 155"
+ "@value": "Jnc22-ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_335AO",
+ "@id": "http://example.org/IBAL#HC_7_W_OCP",
"@type": [
- "http://data.ashrae.org/standard223#Controller"
- ],
- "http://data.ashrae.org/standard223#hasObservtaionLocation": [
- {
- "@id": "http://example.org/IBAL#MotorizedDamper_12"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#d8_pos_c"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 335AO"
+ "@value": "HC 7 W OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#d15_pos_fb",
+ "@id": "http://example.org/IBAL#Jnc6-OCP",
"@type": [
- "http://data.ashrae.org/bacnet/2020#AnalogInputObject",
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/bacnet/2020#description": [
- {
- "@value": "VAV1 Damper Feedback Signal"
- }
- ],
- "http://data.ashrae.org/bacnet/2020#object-identifier": [
- {
- "@value": "analog-input,1"
- }
- ],
- "http://data.ashrae.org/bacnet/2020#object-name": [
- {
- "@value": "d15_pos_fb"
- }
- ],
- "http://data.ashrae.org/bacnet/2020#object-type": [
- {
- "@value": "analog-input"
- }
- ],
- "http://data.ashrae.org/bacnet/2020#objectOf": [
- {
- "@id": "http://example.org/IBAL#VAV_1"
- }
- ],
- "http://data.ashrae.org/bacnet/2020#present-value": [
- {
- "@type": "http://www.w3.org/2001/XMLSchema#float",
- "@value": "0.0"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Voltage"
+ "@id": "http://example.org/IBAL#Segment_22"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "d15 pos fb"
+ "@value": "Jnc6-OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_109",
+ "@id": "http://example.org/IBAL#Channel_87",
"@type": [
"http://data.ashrae.org/standard223#TemperatureSensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#HVAC_Space_3_ICP"
+ "@id": "http://example.org/IBAL#VAV_1_Connection_2"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#zs3_heat_rtd"
+ "@id": "http://example.org/IBAL#vav1_out_rtd"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 109"
+ "@value": "Channel 87"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_74",
+ "@id": "http://example.org/IBAL#Segment_82",
"@type": [
"http://data.ashrae.org/standard223#Connection"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Jnc27-OCP1"
+ "@id": "http://example.org/IBAL#Jnc30-ICP"
},
{
- "@id": "http://example.org/IBAL#ManualTwoWayValve_4_ICP"
+ "@id": "http://example.org/IBAL#WaterPump_3_OCP"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -18582,149 +18542,147 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 74"
+ "@value": "Segment 82"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc34-ICP",
+ "@id": "http://example.org/IBAL#HC_4_OCP",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc34-ICP"
+ "@value": "HC 4 OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#Junction_30",
+ "@id": "http://example.org/IBAL#ahu2_fan_power",
"@type": [
- "http://data.ashrae.org/standard223#Junction"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#Jnc30-ICP"
- },
- {
- "@id": "http://example.org/IBAL#Jnc30-ICP2"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://example.org/IBAL#Jnc30-OCP"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://qudt.org/vocab/unit/W"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Junction 30"
+ "@value": "ahu2 fan power"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc20-OCP2",
+ "@id": "http://example.org/IBAL#Channel_426",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Controller"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://example.org/IBAL#MotorizedDamper_6"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#d11_pos_c"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc20-OCP2"
+ "@value": "Channel 426"
}
]
},
{
- "@id": "http://example.org/IBAL#vav2_out_rtd",
+ "@id": "http://example.org/IBAL#VFD_1_OCP",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/bacnet/2020#description": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@value": "VAV2 Discharge Temperature"
+ "@id": "http://data.ashrae.org/standard223#Electricity-Signal"
}
],
- "http://data.ashrae.org/bacnet/2020#object-identifier": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "analog-input,2"
+ "@value": "VFD 1 OCP"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_21",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
],
- "http://data.ashrae.org/bacnet/2020#object-name": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@value": "vav2_out_rtd"
- }
- ],
- "http://data.ashrae.org/bacnet/2020#object-type": [
+ "@id": "http://example.org/IBAL#Damper_6_ICP"
+ },
{
- "@value": "analog-input"
+ "@id": "http://example.org/IBAL#Jnc7-OCP2"
}
],
- "http://data.ashrae.org/bacnet/2020#objectOf": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#VAV_2"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/bacnet/2020#present-value": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@type": "http://www.w3.org/2001/XMLSchema#float",
- "@value": "70.0"
+ "@value": "Segment 21"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_18",
+ "@type": [
+ "http://data.ashrae.org/standard223#Damper"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "http://example.org/IBAL#Damper_18_ICP"
+ },
{
- "@id": "http://qudt.org/vocab/unit/DEG_F"
+ "@id": "http://example.org/IBAL#Damper_18_OCP"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "vav2 out rtd"
+ "@value": "Motorized damper 18"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc19-OCP",
+ "@id": "http://example.org/IBAL#HVAC_Space_2_ICP",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc19-OCP"
+ "@value": "HVAC Space 2 ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#Segment_23",
+ "@id": "http://example.org/IBAL#Jnc9-OCP",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "http://example.org/IBAL#Damper_14_ICP"
- },
- {
- "@id": "http://example.org/IBAL#Jnc8-OCP1"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -18733,180 +18691,190 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Segment 23"
+ "@value": "Jnc9-OCP"
}
]
},
{
- "@id": "http://example.org/IBAL#d17_pos_c",
+ "@id": "http://example.org/IBAL#HVACZone_1",
"@type": [
- "http://data.ashrae.org/bacnet/2020#AnalogOutputObject",
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://data.ashrae.org/bacnet/2020#description": [
- {
- "@value": "VAV3 Damper Control Signal"
- }
+ "http://data.ashrae.org/standard223#Zone"
],
- "http://data.ashrae.org/bacnet/2020#object-identifier": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@value": "analog-output,2"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
],
- "http://data.ashrae.org/bacnet/2020#object-name": [
+ "http://data.ashrae.org/standard223#hasDomainSpace": [
{
- "@value": "d17_pos_c"
+ "@id": "http://example.org/IBAL#HVACSpace_1"
}
],
- "http://data.ashrae.org/bacnet/2020#object-type": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "analog-output"
+ "@value": "HVACZone 1"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc28-ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/bacnet/2020#objectOf": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://example.org/IBAL#VAV_3"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
- "http://data.ashrae.org/bacnet/2020#present-value": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@type": "http://www.w3.org/2001/XMLSchema#float",
- "@value": "0.0"
+ "@value": "Jnc28-ICP"
}
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Channel_326",
+ "@type": [
+ "http://data.ashrae.org/standard223#FlowSensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Voltage"
+ "@id": "http://example.org/IBAL#Segment_38"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "http://example.org/IBAL#ahu1_f_sa"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "d17 pos c"
+ "@value": "Channel 326"
}
]
},
{
- "@id": "http://example.org/IBAL#VAV_3_Connection_2",
+ "@id": "http://example.org/IBAL#Junction_27",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#Junction"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#HVAC_Space_3_ICP"
- }
- ],
- "http://data.ashrae.org/standard223#connectsAt": [
+ "@id": "http://example.org/IBAL#Jnc27-ICP"
+ },
{
- "@id": "http://example.org/IBAL#VAV_3_OCP"
+ "@id": "http://example.org/IBAL#Jnc27-OCP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc27-OCP2"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "VAV 3 Connection 2"
+ "@value": "Junction 27"
}
]
},
{
- "@id": "http://example.org/IBAL#Jnc11-ICP1",
+ "@id": "http://example.org/IBAL#Channel_405",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Controller"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://example.org/IBAL#HeatingCoil_1"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#ahu2_heat_c"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Jnc11-ICP1"
+ "@value": "Channel 405"
}
]
},
{
- "@id": "http://example.org/IBAL#Damper_15_ICP",
+ "@id": "http://example.org/IBAL#Channel_52",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#ElectricMeter"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://example.org/IBAL#WaterChiller_1"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#ch1_power"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Damper 15 ICP"
+ "@value": "Channel 52"
}
]
},
{
- "@id": "http://example.org/IBAL#VAV_1_Connection_1",
+ "@id": "http://example.org/IBAL#vav1_heat_power",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#connectsAt": [
- {
- "@id": "http://example.org/IBAL#Damper_1_OCP"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://example.org/IBAL#HC_2_ICP"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/W"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "VAV 1 Connection 1"
+ "@value": "vav1 heat power"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_329AO",
+ "@id": "http://example.org/IBAL#Channel_303",
"@type": [
- "http://data.ashrae.org/standard223#Controller"
+ "http://data.ashrae.org/standard223#FlowSensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://example.org/IBAL#MotorizedDamper_13"
+ "@id": "http://example.org/IBAL#Segment_7"
}
],
- "http://data.ashrae.org/standard223#observers": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://example.org/IBAL#d6_pos_c"
+ "@id": "http://example.org/IBAL#vav3_f"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 329AO"
+ "@value": "Channel 303"
}
]
},
{
- "@id": "http://example.org/IBAL#Junction_16",
+ "@id": "http://example.org/IBAL#Segment_43",
"@type": [
- "http://data.ashrae.org/standard223#Junction"
+ "http://data.ashrae.org/standard223#Connection"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://example.org/IBAL#Jnc16-ICP"
- },
- {
- "@id": "http://example.org/IBAL#Jnc16-OCP1"
+ "@id": "http://example.org/IBAL#Damper_15_OCP"
},
{
- "@id": "http://example.org/IBAL#Jnc16-OCP2"
+ "@id": "http://example.org/IBAL#Jnc12-ICP"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -18916,49 +18884,81 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Junction 16"
+ "@value": "Segment 43"
}
]
},
{
- "@id": "http://example.org/IBAL#ahu2_fan_power",
+ "@id": "http://example.org/IBAL#Damper_5_ICP",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
{
- "@id": "http://qudt.org/vocab/unit/W"
+ "@id": "http://example.org/IBAL#MotorizedDamper_5"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "ahu2 fan power"
+ "@value": "Damper 5 ICP"
}
]
},
{
- "@id": "http://example.org/IBAL#Channel_134",
+ "@id": "http://example.org/IBAL#vav2_f",
"@type": [
- "http://data.ashrae.org/standard223#TemperatureSensor"
+ "http://data.ashrae.org/bacnet/2020#AnalogInputObject",
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/bacnet/2020#description": [
{
- "@id": "http://example.org/IBAL#HeatExchange_Connection"
+ "@value": "VAV2 Airflow Rate"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/bacnet/2020#object-identifier": [
{
- "@id": "http://example.org/IBAL#hx3_pg_rtd"
+ "@value": "analog-input,4"
+ }
+ ],
+ "http://data.ashrae.org/bacnet/2020#object-name": [
+ {
+ "@value": "vav2_f"
+ }
+ ],
+ "http://data.ashrae.org/bacnet/2020#object-type": [
+ {
+ "@value": "analog-input"
+ }
+ ],
+ "http://data.ashrae.org/bacnet/2020#objectOf": [
+ {
+ "@id": "http://example.org/IBAL#VAV_2"
+ }
+ ],
+ "http://data.ashrae.org/bacnet/2020#present-value": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#float",
+ "@value": "0.0"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "Channel 129"
+ "@value": "vav2 f"
}
]
}
diff --git a/models/nrel-example.jsonld b/models/nrel-example.jsonld
index f2f51c33..05abb240 100644
--- a/models/nrel-example.jsonld
+++ b/models/nrel-example.jsonld
@@ -1,70 +1,68 @@
[
{
- "@id": "urn:nrel_example/nrel00001076",
+ "@id": "urn:nrel_example/nrel00000622",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001076"
+ "@value": "nrel00000622"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000528",
+ "@id": "urn:nrel_example/nrel00000741",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ "@id": "urn:nrel_example/nrel00000463"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW"
+ "@id": "urn:nrel_example/nrel00001307"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000528"
+ "@value": "nrel00000741"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001216",
+ "@id": "urn:nrel_example/nrel00000508",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001216"
+ "@value": "nrel00000508"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000931",
+ "@id": "urn:nrel_example/nrel00001277",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000678"
+ "@id": "urn:nrel_example/nrel00001080"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001123"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -74,238 +72,265 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000931"
+ "@value": "nrel00001277"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000141",
+ "@id": "urn:nrel_example/nrel00000506",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "http://qudt.org/vocab/unit/A"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000141"
+ "@value": "nrel00000506"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001086",
+ "@id": "urn:nrel_example/nrel00000706",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001086"
+ "@value": "nrel00000706"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000474",
+ "@id": "urn:nrel_example/nrel00000212",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000474"
+ "@value": "nrel00000212"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000668",
+ "@id": "urn:nrel_example/nrel00000481",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000668"
+ "@value": "nrel00000481"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000195",
+ "@id": "urn:nrel_example/nrel00000431",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000195"
+ "@value": "nrel00000431"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001090",
+ "@id": "urn:nrel_example/nrel00000776",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001090"
+ "@value": "nrel00000776"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001017",
+ "@id": "urn:nrel_example/nrel00000916",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00000600"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ {
+ "@id": "urn:nrel_example/nrel00000114"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00001059"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001017"
+ "@value": "nrel00000916"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000189",
+ "@id": "urn:nrel_example/nrel00001139",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000163"
- },
+ "@value": "nrel00001139"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000309",
+ "@type": [
+ "http://data.ashrae.org/standard223#Sensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00001094"
+ "@id": "urn:nrel_example/nrel00000000"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00000211"
+ "@id": "urn:nrel_example/nrel00001220"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000189"
+ "@value": "nrel00000309"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001272",
+ "@id": "urn:nrel_example/nrel00000907",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ "@id": "urn:nrel_example/nrel00000043"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000790"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001182"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001242"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/IN_H2O"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001272"
+ "@value": "nrel00000907"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000013",
+ "@id": "urn:nrel_example/nrel00000199",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000013"
+ "@value": "nrel00000199"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000650",
+ "@id": "urn:nrel_example/nrel00001130",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/A"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000650"
+ "@value": "nrel00001130"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001166",
+ "@id": "urn:nrel_example/nrel00001047",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00001198"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -314,409 +339,488 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001166"
+ "@value": "nrel00001047"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000354",
+ "@id": "urn:nrel_example/nrel00000639",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000354"
+ "@value": "nrel00000639"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000848",
+ "@id": "urn:nrel_example/nrel00000644",
"@type": [
- "http://data.ashrae.org/standard223#CoolingCoil"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000581"
- },
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000754"
+ "@value": "nrel00000644"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000941",
+ "@type": [
+ "http://data.ashrae.org/standard223#DomainSpace"
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000146"
- },
- {
- "@id": "urn:nrel_example/nrel00000570"
+ "@id": "urn:nrel_example/nrel00000251"
},
{
- "@id": "urn:nrel_example/nrel00001013"
- },
+ "@id": "urn:nrel_example/nrel00000846"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:nrel_example/nrel00001323"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000511"
- },
- {
- "@id": "urn:nrel_example/nrel00000727"
- },
- {
- "@id": "urn:nrel_example/nrel00000774"
- },
- {
- "@id": "urn:nrel_example/nrel00001184"
+ "@id": "urn:nrel_example/nrel00000404"
},
{
- "@id": "urn:nrel_example/nrel00001287"
+ "@id": "urn:nrel_example/nrel00000681"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000848"
+ "@value": "nrel00000941"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000275",
+ "@id": "urn:nrel_example/nrel00000580",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#HeatingCoil"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:nrel_example/nrel00000337"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000741"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001190"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:nrel_example/nrel00000229"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000389"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000463"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000756"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000968"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001307"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000275"
+ "@value": "nrel00000580"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001068",
+ "@id": "urn:nrel_example/nrel00000660",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001068"
+ "@value": "nrel00000660"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001165",
+ "@id": "urn:nrel_example/nrel00000299",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00001267"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000567"
- },
+ "@value": "nrel00000299"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000439",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000637"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001165"
+ "@value": "nrel00000439"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000321",
+ "@id": "urn:nrel_example/nrel00001322",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000321"
+ "@value": "nrel00001322"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000942",
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Default",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus",
+ "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@language": "en",
+ "@value": "AlarmStatus-Alarm"
+ },
+ {
+ "@language": "en",
+ "@value": "Override-Default"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000801",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000942"
+ "@value": "nrel00000801"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000496",
+ "@id": "urn:nrel_example/nrel00000020",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000970"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001272"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000496"
+ "@value": "nrel00000020"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000613",
+ "@id": "urn:nrel_example/nrel00001254",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
+ "http://data.ashrae.org/standard223#TerminalUnit"
+ ],
+ "http://data.ashrae.org/standard223#contains": [
+ {
+ "@id": "urn:nrel_example/nrel00000342"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000524"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000686"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000782"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001231"
+ }
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000093"
+ "@id": "urn:nrel_example/nrel00000688"
},
{
- "@id": "urn:nrel_example/nrel00000894"
+ "@id": "urn:nrel_example/nrel00000967"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000952"
+ "@id": "urn:nrel_example/nrel00000176"
},
{
- "@id": "urn:nrel_example/nrel00001088"
+ "@id": "urn:nrel_example/nrel00000865"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001221"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000613"
+ "@value": "nrel00001254"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001205",
+ "@id": "urn:nrel_example/nrel00000350",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000504"
+ "@id": "urn:nrel_example/nrel00000986"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ {
+ "@id": "urn:nrel_example/nrel00000160"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00000263"
+ "@id": "urn:nrel_example/nrel00000225"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001205"
+ "@value": "nrel00000350"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000040",
+ "@id": "urn:nrel_example/nrel00000416",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000287"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000467"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000314"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000391"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000040"
+ "@value": "nrel00000416"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000946",
+ "@id": "urn:nrel_example/nrel00000905",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:nrel_example/nrel00000444"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000597"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000946"
+ "@value": "nrel00000905"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000519",
+ "@id": "urn:nrel_example/nrel00000056",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/A"
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000519"
+ "@value": "nrel00000056"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000908",
+ "@id": "urn:nrel_example/nrel00000275",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000397"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000908"
+ "@value": "nrel00000275"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001218",
+ "@id": "urn:nrel_example/nrel00001293",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00001218"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000509",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000509"
+ "@value": "nrel00001293"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000669",
+ "@id": "urn:nrel_example/nrel00000805",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/IN_H2O"
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000669"
+ "@value": "nrel00000805"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000688",
+ "@id": "urn:nrel_example/nrel00001094",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000688"
+ "@value": "nrel00001094"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000240",
+ "@id": "urn:nrel_example/nrel00000310",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000589"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000240"
+ "@value": "nrel00000310"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001208",
+ "@id": "urn:nrel_example/nrel00001189",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -727,200 +831,186 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001208"
+ "@value": "nrel00001189"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000799",
+ "@id": "urn:nrel_example/nrel00000485",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil"
- ],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000217"
- },
- {
- "@id": "urn:nrel_example/nrel00000613"
- },
- {
- "@id": "urn:nrel_example/nrel00001292"
- }
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000161"
- },
- {
- "@id": "urn:nrel_example/nrel00001056"
- },
- {
- "@id": "urn:nrel_example/nrel00001183"
- },
- {
- "@id": "urn:nrel_example/nrel00001300"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000147"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000565"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000799"
+ "@value": "nrel00000485"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000898",
+ "@id": "urn:nrel_example/nrel00000352",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@value": "nrel00000898"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000115",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000115"
+ "@value": "nrel00000352"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000801",
+ "@id": "urn:nrel_example/nrel00000029",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/Frequency"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/HZ"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000801"
+ "@value": "nrel00000029"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000714",
+ "@id": "urn:nrel_example/nrel00000560",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Energy"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/KiloW-HR"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000714"
+ "@value": "nrel00000560"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000122",
+ "@id": "urn:nrel_example/nrel00000938",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#TerminalUnit"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:nrel_example/nrel00000074"
+ "@id": "urn:nrel_example/nrel00000073"
},
{
- "@id": "urn:nrel_example/nrel00000781"
+ "@id": "urn:nrel_example/nrel00000324"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000510"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001223"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001232"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "urn:nrel_example/nrel00000742"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000961"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000335"
+ "@id": "urn:nrel_example/nrel00000064"
},
{
- "@id": "urn:nrel_example/nrel00001167"
+ "@id": "urn:nrel_example/nrel00000332"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000475"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000122"
+ "@value": "nrel00000938"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000944",
+ "@id": "urn:nrel_example/nrel00001006",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000944"
+ "@value": "nrel00001006"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000622",
+ "@id": "urn:nrel_example/nrel00001202",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000622"
+ "@value": "nrel00001202"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000277",
+ "@id": "urn:nrel_example/nrel00001007",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000277"
+ "@value": "nrel00001007"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000999",
+ "@id": "urn:nrel_example/nrel00000885",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -936,14 +1026,22 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000999"
+ "@value": "nrel00000885"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001049",
+ "@id": "urn:nrel_example/nrel00000725",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Duct"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:nrel_example/nrel00000441"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000590"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -952,168 +1050,149 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001049"
+ "@value": "nrel00000725"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000912",
+ "@id": "urn:nrel_example/nrel00000711",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000912"
+ "@value": "nrel00000711"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000626",
+ "@id": "urn:nrel_example/nrel00000750",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000004"
- },
- {
- "@id": "urn:nrel_example/nrel00000955"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00001030"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001218"
+ "@id": "http://qudt.org/vocab/unit/KiloW"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000626"
+ "@value": "nrel00000750"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000965",
+ "@id": "urn:nrel_example/nrel00001257",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000080"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000859"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000005"
+ "@id": "http://qudt.org/vocab/unit/A"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000965"
+ "@value": "nrel00001257"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000249",
+ "@id": "urn:nrel_example/nrel00000112",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Pump"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000407"
+ },
{
- "@value": "nrel00000249"
+ "@id": "urn:nrel_example/nrel00000621"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000488",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "urn:nrel_example/nrel00000316"
+ },
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000455"
+ },
{
- "@value": "nrel00000488"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000409",
- "@type": [
- "http://data.ashrae.org/standard223#Zone"
- ],
- "http://data.ashrae.org/standard223#hasDomainSpace": [
+ "@id": "urn:nrel_example/nrel00000506"
+ },
{
- "@id": "urn:nrel_example/nrel00000966"
+ "@id": "urn:nrel_example/nrel00000536"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000583"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000666"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000721"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000764"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000851"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001103"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000409"
+ "@value": "nrel00000112"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001043",
+ "@id": "urn:nrel_example/nrel00000491",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00001043"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000487",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:nrel_example/nrel00000864"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000487"
+ "@value": "nrel00000491"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000286",
+ "@id": "urn:nrel_example/nrel00001218",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
@@ -1122,270 +1201,298 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000286"
+ "@value": "nrel00001218"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000564",
+ "@id": "urn:nrel_example/nrel00000094",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/IN_H2O"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000564"
+ "@value": "nrel00000094"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000586",
+ "@id": "urn:nrel_example/nrel00000896",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000642"
+ "@id": "urn:nrel_example/nrel00001049"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000114"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000594"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000586"
+ "@value": "nrel00000896"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000162",
+ "@id": "urn:nrel_example/nrel00000539",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000162"
+ "@value": "nrel00000539"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001091",
+ "@id": "urn:nrel_example/nrel00000982",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#AirHandlingUnit"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:nrel_example/nrel00000007"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000053"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000061"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000254"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000446"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000447"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000683"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000992"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001087"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "urn:nrel_example/nrel00000078"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000211"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000034"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001070"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001091"
+ "@value": "nrel00000982"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000951",
+ "@id": "urn:nrel_example/nrel00000688",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000951"
+ "@value": "nrel00000688"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000990",
+ "@id": "urn:nrel_example/nrel00000724",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000990"
+ "@value": "nrel00000724"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000623",
+ "@id": "urn:nrel_example/nrel00000955",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000623"
+ "@value": "nrel00000955"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000266",
+ "@id": "urn:nrel_example/nrel00000754",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#Pump"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000620"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
+ "@id": "urn:nrel_example/nrel00000376"
+ },
{
- "@id": "urn:nrel_example/nrel00000260"
+ "@id": "urn:nrel_example/nrel00000712"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@value": "nrel00000266"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000841",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:nrel_example/nrel00000044"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000180"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000310"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000370"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000377"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000639"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000868"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000997"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001010"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001257"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000841"
+ "@value": "nrel00000754"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000971",
+ "@id": "urn:nrel_example/nrel00000545",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@value": "nrel00000971"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000756",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000756"
+ "@value": "nrel00000545"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000829",
+ "@id": "urn:nrel_example/nrel00001181",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000600"
- }
- ],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
- {
- "@id": "urn:nrel_example/nrel00000114"
+ "@id": "urn:nrel_example/nrel00000737"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00000847"
+ "@id": "urn:nrel_example/nrel00000915"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000829"
+ "@value": "nrel00001181"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000340",
+ "@id": "urn:nrel_example/nrel00000783",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000051"
+ "@id": "urn:nrel_example/nrel00000970"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000984"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000202"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000340"
+ "@value": "nrel00000783"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000998",
+ "@id": "urn:nrel_example/nrel00000269",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000465"
- },
- {
- "@id": "urn:nrel_example/nrel00000786"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -1394,210 +1501,196 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000998"
+ "@value": "nrel00000269"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001087",
+ "@id": "urn:nrel_example/nrel00000522",
"@type": [
- "http://data.ashrae.org/standard223#Filter"
+ "http://data.ashrae.org/standard223#Pump"
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000107"
+ "@id": "urn:nrel_example/nrel00000801"
},
{
- "@id": "urn:nrel_example/nrel00000908"
+ "@id": "urn:nrel_example/nrel00000957"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00001213"
+ "@id": "urn:nrel_example/nrel00000057"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000144"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000267"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000341"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000352"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000507"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000520"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000900"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001005"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001245"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001087"
+ "@value": "nrel00000522"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000461",
+ "@id": "urn:nrel_example/nrel00000075",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00001198"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000461"
+ "@value": "nrel00000075"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001039",
+ "@id": "urn:nrel_example/nrel00000411",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-FlowStatus"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001039"
+ "@value": "nrel00000411"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000738",
+ "@id": "urn:nrel_example/nrel00000594",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000738"
+ "@value": "nrel00000594"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000513",
+ "@id": "urn:nrel_example/nrel00000390",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000513"
+ "@value": "nrel00000390"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000117",
+ "@id": "urn:nrel_example/nrel00000391",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000966"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000282"
+ "@value": "nrel00000391"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001086",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000845"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000117"
+ "@value": "nrel00001086"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000797",
+ "@id": "urn:nrel_example/nrel00000281",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:nrel_example/nrel00001023"
- }
- ],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000797"
+ "@value": "nrel00000281"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001303",
+ "@id": "urn:nrel_example/nrel00000883",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000622"
- },
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000682"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000286"
- },
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000679"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00001303"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000698",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
- {
- "@id": "http://qudt.org/vocab/unit/PERCENT"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00000698"
+ "@value": "nrel00000883"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001221",
+ "@id": "urn:nrel_example/nrel00000139",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -1613,217 +1706,183 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001221"
+ "@value": "nrel00000139"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000077",
+ "@id": "urn:nrel_example/nrel00000515",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000424"
- },
- {
- "@id": "urn:nrel_example/nrel00000892"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@value": "nrel00000077"
+ "@id": "urn:nrel_example/nrel00000745"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000988",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:nrel_example/nrel00000160"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:nrel_example/nrel00001286"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000988"
+ "@value": "nrel00000515"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000529",
+ "@id": "urn:nrel_example/nrel00001093",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000529"
+ "@value": "nrel00001093"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000012",
+ "@id": "urn:nrel_example/nrel00000810",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000012"
+ "@value": "nrel00000810"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000624",
+ "@id": "urn:nrel_example/nrel00001256",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
+ "@id": "urn:nrel_example/nrel00000678"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/A"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000624"
+ "@value": "nrel00001256"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000200",
+ "@id": "urn:nrel_example/nrel00000148",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00001046"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00000354"
+ "@id": "urn:nrel_example/nrel00001067"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000200"
+ "@value": "nrel00000148"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001081",
+ "@id": "urn:nrel_example/nrel00000530",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001081"
+ "@value": "nrel00000530"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000609",
+ "@id": "urn:nrel_example/nrel00000070",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/A"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000609"
+ "@value": "nrel00000070"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000811",
+ "@id": "urn:nrel_example/nrel00001157",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Frequency"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/HZ"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000811"
+ "@value": "nrel00001157"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000607",
+ "@id": "urn:nrel_example/nrel00000314",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-FlowStatus"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000607"
+ "@value": "nrel00000314"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000603",
+ "@id": "urn:nrel_example/nrel00001123",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -1832,28 +1891,28 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000603"
+ "@value": "nrel00001123"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001030",
+ "@id": "urn:nrel_example/nrel00000401",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001030"
+ "@value": "nrel00000401"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000194",
+ "@id": "urn:nrel_example/nrel00000878",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
@@ -1864,193 +1923,157 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000194"
+ "@value": "nrel00000878"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000055",
+ "@id": "urn:nrel_example/nrel00000796",
"@type": [
- "http://data.ashrae.org/standard223#Fan"
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000079"
- },
- {
- "@id": "urn:nrel_example/nrel00000222"
- }
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000016"
- },
- {
- "@id": "urn:nrel_example/nrel00000037"
- },
- {
- "@id": "urn:nrel_example/nrel00000156"
- },
- {
- "@id": "urn:nrel_example/nrel00000195"
- },
- {
- "@id": "urn:nrel_example/nrel00000234"
- },
- {
- "@id": "urn:nrel_example/nrel00000479"
- },
- {
- "@id": "urn:nrel_example/nrel00000922"
- },
- {
- "@id": "urn:nrel_example/nrel00001073"
- },
- {
- "@id": "urn:nrel_example/nrel00001128"
- },
- {
- "@id": "urn:nrel_example/nrel00001173"
- },
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00001214"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000055"
+ "@value": "nrel00000796"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000874",
+ "@id": "urn:nrel_example/nrel00000383",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:nrel_example/nrel00000430"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000795"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000874"
+ "@value": "nrel00000383"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000310",
+ "@id": "urn:nrel_example/nrel00000809",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000310"
+ "@value": "nrel00000809"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001214",
+ "@id": "urn:nrel_example/nrel00001190",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "urn:nrel_example/nrel00000389"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:nrel_example/nrel00000968"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001214"
+ "@value": "nrel00001190"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000080",
+ "@id": "urn:nrel_example/nrel00001180",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000220"
- },
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00001105"
+ "@id": "urn:nrel_example/nrel00000172"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000005"
+ "@id": "urn:nrel_example/nrel00000885"
},
{
- "@id": "urn:nrel_example/nrel00000319"
+ "@id": "urn:nrel_example/nrel00001179"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000080"
+ "@value": "nrel00001180"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000032",
+ "@id": "urn:nrel_example/nrel00000790",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000032"
+ "@value": "nrel00000790"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000276",
+ "@id": "urn:nrel_example/nrel00000182",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Frequency"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/HZ"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000276"
+ "@value": "nrel00000182"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001077",
+ "@id": "urn:nrel_example/nrel00000248",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -2059,76 +2082,74 @@
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:nrel_example/nrel00000134"
- }
- ],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001077"
+ "@value": "nrel00000248"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000209",
+ "@id": "urn:nrel_example/nrel00000457",
"@type": [
- "http://data.ashrae.org/standard223#FanCoilUnit"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000099"
- },
- {
- "@id": "urn:nrel_example/nrel00000135"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000904"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000131"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000355"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000392"
- },
- {
- "@id": "urn:nrel_example/nrel00000752"
- },
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000805"
- },
+ "@value": "nrel00000457"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000666",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001160"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001233"
+ "@id": "http://qudt.org/vocab/unit/KiloW"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Cooling"
- },
+ "@value": "nrel00000666"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000353",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000209"
+ "@value": "nrel00000353"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000492",
+ "@id": "urn:nrel_example/nrel00001153",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
@@ -2137,35 +2158,43 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000492"
+ "@value": "nrel00001153"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000041",
+ "@id": "urn:nrel_example/nrel00001056",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://qudt.org/vocab/unit/A"
+ "@id": "urn:nrel_example/nrel00001265"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000041"
+ "@value": "nrel00001056"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000208",
+ "@id": "urn:nrel_example/nrel00001198",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Duct"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:nrel_example/nrel00000461"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001166"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -2174,49 +2203,49 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000208"
+ "@value": "nrel00001198"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001135",
+ "@id": "urn:nrel_example/nrel00000607",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-FlowStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001135"
+ "@value": "nrel00000607"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000005",
+ "@id": "urn:nrel_example/nrel00000968",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000005"
+ "@value": "nrel00000968"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001158",
+ "@id": "urn:nrel_example/nrel00001238",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -2232,128 +2261,121 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001158"
+ "@value": "nrel00001238"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000050",
+ "@id": "urn:nrel_example/nrel00000870",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Pump"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000901"
+ },
{
- "@value": "nrel00000050"
+ "@id": "urn:nrel_example/nrel00000975"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000541",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000177"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000279"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000547"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000863"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000972"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001045"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001053"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001175"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001253"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001310"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000541"
+ "@value": "nrel00000870"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001243",
+ "@id": "urn:nrel_example/nrel00001188",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000281"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000708"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000866"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001243"
+ "@value": "nrel00001188"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001131",
+ "@id": "urn:nrel_example/nrel00000748",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000941"
- }
- ],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
- {
- "@id": "urn:nrel_example/nrel00000121"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
- {
- "@id": "urn:nrel_example/nrel00000681"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001131"
+ "@value": "nrel00000748"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001225",
+ "@id": "urn:nrel_example/nrel00000048",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@value": "nrel00001225"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000784",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000784"
+ "@value": "nrel00000048"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001082",
+ "@id": "urn:nrel_example/nrel00001239",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -2369,15 +2391,20 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001082"
+ "@value": "nrel00001239"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000864",
+ "@id": "urn:nrel_example/nrel00000899",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:nrel_example/nrel00000875"
+ }
+ ],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
@@ -2385,91 +2412,117 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000864"
+ "@value": "nrel00000899"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001244",
+ "@id": "urn:nrel_example/nrel00000073",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "urn:nrel_example/nrel00000961"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000332"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001244"
+ "@value": "nrel00000073"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000592",
+ "@id": "urn:nrel_example/nrel00000102",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000592"
+ "@value": "nrel00000102"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001079",
+ "@id": "urn:nrel_example/nrel00000187",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#TerminalUnit"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:nrel_example/nrel00000966"
+ "@id": "urn:nrel_example/nrel00000205"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000273"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000369"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000925"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001315"
}
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000282"
+ "@id": "urn:nrel_example/nrel00000441"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001047"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000109"
+ "@id": "urn:nrel_example/nrel00000118"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000132"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000758"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001079"
+ "@value": "nrel00000187"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001054",
+ "@id": "urn:nrel_example/nrel00000728",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/A"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001054"
+ "@value": "nrel00000728"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000720",
+ "@id": "urn:nrel_example/nrel00001208",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -2478,51 +2531,83 @@
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000441"
+ "@value": "nrel00001208"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001000",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000720"
+ "@value": "nrel00001000"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001274",
+ "@id": "urn:nrel_example/nrel00000814",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000078"
+ "@value": "nrel00000814"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000638",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001274"
+ "@value": "nrel00000638"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000011",
+ "@id": "urn:nrel_example/nrel00000410",
"@type": [
- "http://www.w3.org/2002/07/owl#Ontology"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ {
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ }
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000011"
+ "@value": "nrel00000410"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000202",
+ "@id": "urn:nrel_example/nrel00001011",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -2538,53 +2623,60 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000202"
+ "@value": "nrel00001011"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000600",
+ "@id": "urn:nrel_example/nrel00000490",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000439"
+ "@id": "urn:nrel_example/nrel00001020"
},
{
- "@id": "urn:nrel_example/nrel00001049"
- }
- ],
- "http://data.ashrae.org/standard223#hasDomain": [
- {
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "urn:nrel_example/nrel00001200"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000847"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001059"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000600"
+ "@value": "nrel00000490"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000807",
+ "@id": "urn:nrel_example/nrel00001113",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#Junction"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000045"
+ "@id": "urn:nrel_example/nrel00000043"
},
{
- "@id": "urn:nrel_example/nrel00001157"
+ "@id": "urn:nrel_example/nrel00000790"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000802"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000841"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001182"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001203"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001242"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -2594,244 +2686,205 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000807"
+ "@value": "nrel00001113"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000336",
+ "@id": "urn:nrel_example/nrel00000818",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000818"
+ "@id": "urn:nrel_example/nrel00000221"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001086"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:nrel_example/nrel00000471"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000739"
},
{
- "@id": "urn:nrel_example/nrel00000680"
+ "@id": "urn:nrel_example/nrel00001130"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000336"
+ "@value": "nrel00000818"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000204",
+ "@id": "urn:nrel_example/nrel00000861",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/KiloW"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000204"
+ "@value": "nrel00000861"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001332",
+ "@id": "urn:nrel_example/nrel00001076",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Frequency"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/HZ"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001332"
+ "@value": "nrel00001076"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000103",
+ "@id": "urn:nrel_example/nrel00000370",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/KiloW"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000103"
+ "@value": "nrel00000370"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000102",
+ "@id": "urn:nrel_example/nrel00000884",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000102"
+ "@value": "nrel00000884"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000272",
+ "@id": "urn:nrel_example/nrel00001077",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://qudt.org/vocab/unit/IN_H2O"
+ "@id": "urn:nrel_example/nrel00000134"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000272"
+ "@value": "nrel00001077"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000406",
+ "@id": "urn:nrel_example/nrel00000523",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00001211"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000406"
+ "@value": "nrel00000523"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000361",
+ "@id": "urn:nrel_example/nrel00000628",
"@type": [
- "http://data.ashrae.org/standard223#CoolingCoil"
- ],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000313"
- },
- {
- "@id": "urn:nrel_example/nrel00000870"
- }
+ "http://data.ashrae.org/standard223#Valve"
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000030"
- },
- {
- "@id": "urn:nrel_example/nrel00000704"
- },
- {
- "@id": "urn:nrel_example/nrel00001034"
+ "@id": "urn:nrel_example/nrel00000677"
},
{
- "@id": "urn:nrel_example/nrel00001264"
+ "@id": "urn:nrel_example/nrel00001262"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000325"
- },
- {
- "@id": "urn:nrel_example/nrel00000599"
- },
- {
- "@id": "urn:nrel_example/nrel00000719"
- },
- {
- "@id": "urn:nrel_example/nrel00000773"
+ "@id": "urn:nrel_example/nrel00000632"
},
{
- "@id": "urn:nrel_example/nrel00001313"
+ "@id": "urn:nrel_example/nrel00000716"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000361"
+ "@value": "nrel00000628"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000454",
+ "@id": "urn:nrel_example/nrel00000645",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000019"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001018"
+ "@id": "http://qudt.org/vocab/quantitykind/Energy"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000411"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000962"
+ "@id": "http://qudt.org/vocab/unit/KiloW-HR"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000454"
+ "@value": "nrel00000645"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000022",
+ "@id": "urn:nrel_example/nrel00000331",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000190"
- },
- {
- "@id": "urn:nrel_example/nrel00000366"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -2840,523 +2893,520 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000022"
+ "@value": "nrel00000331"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001138",
+ "@id": "urn:nrel_example/nrel00000292",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001138"
+ "@value": "nrel00000292"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000236",
+ "@id": "urn:nrel_example/nrel00001124",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000236"
+ "@value": "nrel00001124"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001224",
+ "@id": "urn:nrel_example/nrel00000685",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001224"
+ "@value": "nrel00000685"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001163",
+ "@id": "urn:nrel_example/nrel00000566",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/IN_H2O"
+ "@id": "http://qudt.org/vocab/unit/KiloW"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001163"
+ "@value": "nrel00000566"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000616",
+ "@id": "urn:nrel_example/nrel00000492",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000616"
+ "@value": "nrel00000492"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000754",
+ "@id": "urn:nrel_example/nrel00000058",
"@type": [
- "http://data.ashrae.org/standard223#Pump"
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000376"
- },
- {
- "@id": "urn:nrel_example/nrel00000712"
- }
+ "http://data.ashrae.org/standard223#Junction"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000044"
- },
- {
- "@id": "urn:nrel_example/nrel00000180"
- },
- {
- "@id": "urn:nrel_example/nrel00000310"
- },
- {
- "@id": "urn:nrel_example/nrel00000370"
- },
- {
- "@id": "urn:nrel_example/nrel00000377"
- },
- {
- "@id": "urn:nrel_example/nrel00000639"
- },
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000868"
+ "@id": "urn:nrel_example/nrel00000760"
},
{
- "@id": "urn:nrel_example/nrel00000997"
+ "@id": "urn:nrel_example/nrel00000984"
},
{
- "@id": "urn:nrel_example/nrel00001010"
- },
+ "@id": "urn:nrel_example/nrel00001260"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001257"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000754"
+ "@value": "nrel00000058"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000168",
+ "@id": "urn:nrel_example/nrel00000929",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001265"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000042"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000168"
+ "@value": "nrel00000929"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000155",
+ "@id": "urn:nrel_example/nrel00000942",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000862"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000464"
+ "@value": "nrel00000942"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000454",
+ "@type": [
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000417"
+ "@id": "urn:nrel_example/nrel00000019"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001018"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000411"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000962"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000155"
+ "@value": "nrel00000454"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001141",
+ "@id": "urn:nrel_example/nrel00000695",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001141"
+ "@value": "nrel00000695"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000612",
+ "@id": "urn:nrel_example/nrel00000745",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000612"
+ "@value": "nrel00000745"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000895",
+ "@id": "urn:nrel_example/nrel00001079",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:nrel_example/nrel00000966"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:nrel_example/nrel00000282"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000109"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000895"
+ "@value": "nrel00001079"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000291",
+ "@id": "urn:nrel_example/nrel00000425",
"@type": [
- "http://data.ashrae.org/standard223#Damper"
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000169"
- },
- {
- "@id": "urn:nrel_example/nrel00001009"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000027"
- },
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000837"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000291"
+ "@value": "nrel00000425"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000654",
+ "@id": "urn:nrel_example/nrel00001290",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000654"
+ "@value": "nrel00001290"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000392",
+ "@id": "urn:nrel_example/nrel00000513",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000392"
+ "@value": "nrel00000513"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001315",
+ "@id": "urn:nrel_example/nrel00000648",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000441"
+ "@id": "http://qudt.org/vocab/quantitykind/Frequency"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000132"
+ "@id": "http://qudt.org/vocab/unit/HZ"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001315"
+ "@value": "nrel00000648"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001106",
+ "@id": "urn:nrel_example/nrel00000578",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-FlowStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001106"
+ "@value": "nrel00000578"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000598",
+ "@id": "urn:nrel_example/nrel00000304",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000598"
+ "@value": "nrel00000304"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000437",
+ "@id": "urn:nrel_example/nrel00000656",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:nrel_example/nrel00000736"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@value": "nrel00000437"
+ "@id": "urn:nrel_example/nrel00000969"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000222",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00001295"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000222"
+ "@value": "nrel00000656"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000215",
+ "@id": "urn:nrel_example/nrel00000763",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000215"
+ "@value": "nrel00000763"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000563",
+ "@id": "urn:nrel_example/nrel00000226",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#CoolingCoil"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "urn:nrel_example/nrel00000031"
+ },
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:nrel_example/nrel00000371"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@value": "nrel00000563"
+ "@id": "urn:nrel_example/nrel00000063"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000269"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000663"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001316"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000788",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00000204"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000213"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000557"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000803"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001293"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000788"
+ "@value": "nrel00000226"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000033",
+ "@id": "urn:nrel_example/nrel00000537",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000033"
+ "@value": "nrel00000537"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000889",
+ "@id": "urn:nrel_example/nrel00001317",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000889"
+ "@value": "nrel00001317"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000154",
+ "@id": "urn:nrel_example/nrel00000336",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ "@id": "urn:nrel_example/nrel00000818"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/IN_H2O"
+ "@id": "urn:nrel_example/nrel00000471"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000680"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000154"
+ "@value": "nrel00000336"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000825",
+ "@id": "urn:nrel_example/nrel00000567",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -3372,87 +3422,66 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000825"
+ "@value": "nrel00000567"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001025",
+ "@id": "urn:nrel_example/nrel00000055",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Fan"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000079"
+ },
{
- "@value": "nrel00001025"
+ "@id": "urn:nrel_example/nrel00000222"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00001327",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000016"
+ },
{
- "@value": "nrel00001327"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000760",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:nrel_example/nrel00000037"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000156"
+ },
{
- "@value": "nrel00000760"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00001162",
- "@type": [
- "http://data.ashrae.org/standard223#Valve"
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "@id": "urn:nrel_example/nrel00000195"
+ },
{
- "@id": "urn:nrel_example/nrel00000069"
+ "@id": "urn:nrel_example/nrel00000234"
},
{
- "@id": "urn:nrel_example/nrel00000482"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "@id": "urn:nrel_example/nrel00000479"
+ },
{
- "@id": "urn:nrel_example/nrel00000111"
+ "@id": "urn:nrel_example/nrel00000922"
},
{
- "@id": "urn:nrel_example/nrel00001319"
+ "@id": "urn:nrel_example/nrel00001073"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001128"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001173"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001214"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001162"
+ "@value": "nrel00000055"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000844",
+ "@id": "urn:nrel_example/nrel00000253",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -3468,51 +3497,40 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000844"
+ "@value": "nrel00000253"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001171",
+ "@id": "urn:nrel_example/nrel00000323",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
- }
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@value": "nrel00001171"
+ "@id": "urn:nrel_example/nrel00000631"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000993",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:nrel_example/nrel00000241"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:nrel_example/nrel00000665"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000993"
+ "@value": "nrel00000323"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001316",
+ "@id": "urn:nrel_example/nrel00000252",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -3521,121 +3539,110 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001316"
+ "@value": "nrel00000252"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001329",
+ "@id": "urn:nrel_example/nrel00001225",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000207"
- }
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000709"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001329"
+ "@value": "nrel00001225"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000219",
+ "@id": "urn:nrel_example/nrel00001046",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000219"
+ "@value": "nrel00001046"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000258",
+ "@id": "urn:nrel_example/nrel00001083",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000459"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001007"
+ "@id": "http://qudt.org/vocab/quantitykind/Energy"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/KiloW-HR"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000258"
+ "@value": "nrel00001083"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000927",
+ "@id": "urn:nrel_example/nrel00000766",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/KiloW"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000927"
+ "@value": "nrel00000766"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001197",
+ "@id": "urn:nrel_example/nrel00000500",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000466"
- },
- {
- "@id": "urn:nrel_example/nrel00000590"
- }
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "urn:nrel_example/nrel00001125"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000499"
+ "@id": "urn:nrel_example/nrel00000216"
},
{
- "@id": "urn:nrel_example/nrel00001306"
+ "@id": "urn:nrel_example/nrel00001168"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001197"
+ "@value": "nrel00000500"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001157",
+ "@id": "urn:nrel_example/nrel00001064",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -3646,154 +3653,186 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001157"
+ "@value": "nrel00001064"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000765",
+ "@id": "urn:nrel_example/nrel00001016",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000765"
+ "@value": "nrel00001016"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000416",
+ "@id": "urn:nrel_example/nrel00000755",
"@type": [
"http://data.ashrae.org/standard223#Valve"
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000287"
+ "@id": "urn:nrel_example/nrel00000380"
},
{
- "@id": "urn:nrel_example/nrel00000467"
+ "@id": "urn:nrel_example/nrel00000491"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000314"
+ "@id": "urn:nrel_example/nrel00000473"
},
{
- "@id": "urn:nrel_example/nrel00000391"
+ "@id": "urn:nrel_example/nrel00000883"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000416"
+ "@value": "nrel00000755"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000968",
+ "@id": "urn:nrel_example/nrel00000997",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ {
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000997"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000276",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Frequency"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/HZ"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000968"
+ "@value": "nrel00000276"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000181",
+ "@id": "urn:nrel_example/nrel00000291",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Damper"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "urn:nrel_example/nrel00000169"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001009"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:nrel_example/nrel00000027"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000837"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000181"
+ "@value": "nrel00000291"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000666",
+ "@id": "urn:nrel_example/nrel00000730",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000666"
+ "@value": "nrel00000730"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001180",
+ "@id": "urn:nrel_example/nrel00001232",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#HeatingCoil"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:nrel_example/nrel00000172"
+ "@id": "urn:nrel_example/nrel00000309"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000602"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001303"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000000"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000032"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000465"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001284"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000885"
+ "@id": "urn:nrel_example/nrel00000358"
},
{
- "@id": "urn:nrel_example/nrel00001179"
+ "@id": "urn:nrel_example/nrel00001220"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001180"
+ "@value": "nrel00001232"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000364",
+ "@id": "urn:nrel_example/nrel00000219",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -3802,179 +3841,176 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000364"
+ "@value": "nrel00000219"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000246",
+ "@id": "urn:nrel_example/nrel00001142",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#HeatingCoil"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:nrel_example/nrel00000649"
+ "@id": "urn:nrel_example/nrel00000266"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000472"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000934"
}
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000553"
+ "@id": "urn:nrel_example/nrel00000104"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000620"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001141"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001241"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000182"
+ "@id": "urn:nrel_example/nrel00000256"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000260"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000246"
+ "@value": "nrel00001142"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000805",
+ "@id": "urn:nrel_example/nrel00000165",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000805"
+ "@value": "nrel00000165"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000478",
+ "@id": "urn:nrel_example/nrel00000505",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#HeatingCoil"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:nrel_example/nrel00000474"
- }
- ],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "@id": "urn:nrel_example/nrel00000626"
+ },
{
- "@id": "urn:nrel_example/nrel00000708"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
+ "@id": "urn:nrel_example/nrel00001071"
+ },
{
- "@id": "urn:nrel_example/nrel00000345"
+ "@id": "urn:nrel_example/nrel00001266"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@value": "nrel00000478"
+ "@id": "urn:nrel_example/nrel00000321"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000748"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000983"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001117"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00001097",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00000936"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001236"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001097"
+ "@value": "nrel00000505"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000923",
+ "@id": "urn:nrel_example/nrel00000177",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000642"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000067"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000923"
+ "@value": "nrel00000177"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000171",
+ "@id": "urn:nrel_example/nrel00000081",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000098"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001207"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000171"
+ "@value": "nrel00000081"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000833",
+ "@id": "urn:nrel_example/nrel00000849",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000074"
- }
- ],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
- {
- "@id": "urn:nrel_example/nrel00001027"
+ "@id": "urn:nrel_example/nrel00000948"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00000206"
+ "@id": "urn:nrel_example/nrel00000048"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000833"
+ "@value": "nrel00000849"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001302",
+ "@id": "urn:nrel_example/nrel00001034",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -3983,130 +4019,122 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001302"
+ "@value": "nrel00001034"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000533",
+ "@id": "urn:nrel_example/nrel00001145",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000188"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000418"
- },
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00001012"
+ "@value": "nrel00001145"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000435",
+ "@type": [
+ "http://data.ashrae.org/standard223#TerminalUnit"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:nrel_example/nrel00000485"
+ "@id": "urn:nrel_example/nrel00000110"
},
{
- "@id": "urn:nrel_example/nrel00000579"
+ "@id": "urn:nrel_example/nrel00000142"
},
{
- "@id": "urn:nrel_example/nrel00001285"
+ "@id": "urn:nrel_example/nrel00000460"
},
{
- "@id": "urn:nrel_example/nrel00001299"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000166"
+ "@id": "urn:nrel_example/nrel00000849"
},
{
- "@id": "urn:nrel_example/nrel00000457"
+ "@id": "urn:nrel_example/nrel00000917"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@value": "nrel00000533"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000423",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:nrel_example/nrel00000462"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:nrel_example/nrel00000948"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@value": "nrel00000423"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000975",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:nrel_example/nrel00000048"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:nrel_example/nrel00000124"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000641"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000975"
+ "@value": "nrel00000435"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000431",
+ "@id": "urn:nrel_example/nrel00001053",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Energy"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/KiloW-HR"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000431"
+ "@value": "nrel00001053"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000044",
+ "@id": "urn:nrel_example/nrel00000200",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Energy"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW-HR"
+ "@id": "urn:nrel_example/nrel00000354"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000044"
+ "@value": "nrel00000200"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000025",
+ "@id": "urn:nrel_example/nrel00000098",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -4117,70 +4145,65 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000025"
+ "@value": "nrel00000098"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000861",
+ "@id": "urn:nrel_example/nrel00001013",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000861"
+ "@value": "nrel00001013"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000148",
+ "@id": "urn:nrel_example/nrel00000840",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00001046"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001067"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000148"
+ "@value": "nrel00000840"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001215",
+ "@id": "urn:nrel_example/nrel00000687",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001215"
+ "@value": "nrel00000687"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000399",
+ "@id": "urn:nrel_example/nrel00001105",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -4191,105 +4214,114 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000399"
+ "@value": "nrel00001105"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001160",
+ "@id": "urn:nrel_example/nrel00000196",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001160"
+ "@value": "nrel00000196"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000855",
+ "@id": "urn:nrel_example/nrel00001012",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00001299"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000166"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000855"
+ "@value": "nrel00001012"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000400",
+ "@id": "urn:nrel_example/nrel00000503",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000305"
+ "@id": "urn:nrel_example/nrel00000649"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ {
+ "@id": "urn:nrel_example/nrel00000553"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00000738"
+ "@id": "urn:nrel_example/nrel00001178"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000400"
+ "@value": "nrel00000503"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000875",
+ "@id": "urn:nrel_example/nrel00001089",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#HeatRecoveryCoil"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000107"
+ "@id": "urn:nrel_example/nrel00000351"
},
{
- "@id": "urn:nrel_example/nrel00000899"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:nrel_example/nrel00000618"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000821"
+ },
{
- "@value": "nrel00000875"
+ "@id": "urn:nrel_example/nrel00001304"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000082",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000315"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000368"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000431"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000488"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000082"
+ "@value": "nrel00001089"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000758",
+ "@id": "urn:nrel_example/nrel00001067",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -4305,311 +4337,329 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000758"
+ "@value": "nrel00001067"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000828",
+ "@id": "urn:nrel_example/nrel00000626",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000251"
- }
- ],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "@id": "urn:nrel_example/nrel00000004"
+ },
{
- "@id": "urn:nrel_example/nrel00000121"
+ "@id": "urn:nrel_example/nrel00000955"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000071"
+ "@id": "urn:nrel_example/nrel00001030"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001218"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000828"
+ "@value": "nrel00000626"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000709",
+ "@id": "urn:nrel_example/nrel00000420",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000709"
+ "@value": "nrel00000420"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000567",
+ "@id": "urn:nrel_example/nrel00000756",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000567"
+ "@value": "nrel00000756"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000182",
+ "@id": "urn:nrel_example/nrel00000362",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#FanCoilUnit"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:nrel_example/nrel00000830"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000839"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001176"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:nrel_example/nrel00000714"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001020"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@value": "nrel00000182"
+ "@id": "urn:nrel_example/nrel00000527"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000643"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000812"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001065"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001082"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000279",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "http://data.ashrae.org/standard223#Role-Cooling"
+ },
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000279"
+ "@value": "nrel00000362"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000046",
+ "@id": "urn:nrel_example/nrel00001102",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000046"
+ "@value": "nrel00001102"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001002",
+ "@id": "urn:nrel_example/nrel00001321",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:nrel_example/nrel00000265"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000876"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001002"
+ "@value": "nrel00001321"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000926",
+ "@id": "urn:nrel_example/nrel00000906",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-FlowStatus"
+ "@id": "urn:nrel_example/nrel00000827"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000852"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000422"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000855"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000926"
+ "@value": "nrel00000906"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000885",
+ "@id": "urn:nrel_example/nrel00000475",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000885"
+ "@value": "nrel00000475"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000685",
+ "@id": "urn:nrel_example/nrel00000564",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@value": "nrel00000685"
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000432",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/IN_H2O"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000432"
+ "@value": "nrel00000564"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000556",
+ "@id": "urn:nrel_example/nrel00000699",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:nrel_example/nrel00000535"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000556"
+ "@value": "nrel00000699"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001187",
+ "@id": "urn:nrel_example/nrel00000630",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil"
+ "http://data.ashrae.org/standard223#CoolingCoil"
],
"http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:nrel_example/nrel00000733"
- },
- {
- "@id": "urn:nrel_example/nrel00001181"
+ "@id": "urn:nrel_example/nrel00000707"
},
{
- "@id": "urn:nrel_example/nrel00001205"
+ "@id": "urn:nrel_example/nrel00001195"
}
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000504"
+ "@id": "urn:nrel_example/nrel00000353"
},
{
- "@id": "urn:nrel_example/nrel00000595"
+ "@id": "urn:nrel_example/nrel00000390"
},
{
- "@id": "urn:nrel_example/nrel00000705"
+ "@id": "urn:nrel_example/nrel00001122"
},
{
- "@id": "urn:nrel_example/nrel00000737"
+ "@id": "urn:nrel_example/nrel00001328"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000263"
+ "@id": "urn:nrel_example/nrel00000303"
},
{
- "@id": "urn:nrel_example/nrel00000915"
+ "@id": "urn:nrel_example/nrel00000333"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000534"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000993"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001145"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001187"
+ "@value": "nrel00000630"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000448",
+ "@id": "urn:nrel_example/nrel00000402",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/Energy"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/KiloW-HR"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000448"
+ "@value": "nrel00000402"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001250",
+ "@id": "urn:nrel_example/nrel00000760",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -4618,144 +4668,179 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001250"
+ "@value": "nrel00000760"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000659",
+ "@id": "urn:nrel_example/nrel00000343",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00000134"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000669"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000659"
+ "@value": "nrel00000343"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000482",
+ "@id": "urn:nrel_example/nrel00000186",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000482"
+ "@value": "nrel00000186"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000711",
+ "@id": "urn:nrel_example/nrel00000043",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000043"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000377",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000711"
+ "@value": "nrel00000377"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000501",
+ "@id": "urn:nrel_example/nrel00000918",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000236"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00001165"
+ "@value": "nrel00000918"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001147",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000567"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000501"
+ "@value": "nrel00001147"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001085",
+ "@id": "urn:nrel_example/nrel00000859",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:nrel_example/nrel00000080"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:nrel_example/nrel00000284"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000987"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001085"
+ "@value": "nrel00000859"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001088",
+ "@id": "urn:nrel_example/nrel00001140",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001088"
+ "@value": "nrel00001140"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001282",
+ "@id": "urn:nrel_example/nrel00000712",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001282"
+ "@value": "nrel00000712"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000170",
+ "@id": "urn:nrel_example/nrel00001066",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -4771,145 +4856,144 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000170"
+ "@value": "nrel00001066"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000329",
+ "@id": "urn:nrel_example/nrel00000775",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000329"
+ "@value": "nrel00000775"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000804",
+ "@id": "urn:nrel_example/nrel00000044",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000612"
+ "@id": "http://qudt.org/vocab/quantitykind/Energy"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000895"
+ "@id": "http://qudt.org/vocab/unit/KiloW-HR"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000804"
+ "@value": "nrel00000044"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000728",
+ "@id": "urn:nrel_example/nrel00001326",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
+ "@id": "http://qudt.org/vocab/quantitykind/Energy"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/A"
+ "@id": "http://qudt.org/vocab/unit/KiloW-HR"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000728"
+ "@value": "nrel00001326"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001241",
+ "@id": "urn:nrel_example/nrel00001331",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001241"
+ "@value": "nrel00001331"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000093",
+ "@id": "urn:nrel_example/nrel00000366",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000093"
+ "@value": "nrel00000366"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000058",
+ "@id": "urn:nrel_example/nrel00000193",
"@type": [
- "http://data.ashrae.org/standard223#Junction"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000760"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000984"
- },
+ "@id": "urn:nrel_example/nrel00000939"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "urn:nrel_example/nrel00001260"
+ "@id": "urn:nrel_example/nrel00000708"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000308"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000058"
+ "@value": "nrel00000193"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000601",
+ "@id": "urn:nrel_example/nrel00000957",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000601"
+ "@value": "nrel00000957"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001149",
+ "@id": "urn:nrel_example/nrel00001323",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -4918,93 +5002,98 @@
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000742"
+ "@value": "nrel00001323"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000109",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001149"
+ "@value": "nrel00000109"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000878",
+ "@id": "urn:nrel_example/nrel00000037",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000878"
+ "@value": "nrel00000037"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000749",
+ "@id": "urn:nrel_example/nrel00000378",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000715"
+ "@id": "urn:nrel_example/nrel00000220"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ {
+ "@id": "urn:nrel_example/nrel00000859"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00000946"
+ "@id": "urn:nrel_example/nrel00000284"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000749"
+ "@value": "nrel00000378"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000706",
+ "@id": "urn:nrel_example/nrel00000116",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
+ "@id": "http://qudt.org/vocab/quantitykind/Energy"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/V"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00000706"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00001294",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/KiloW-HR"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001294"
+ "@value": "nrel00000116"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000081",
+ "@id": "urn:nrel_example/nrel00001167",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -5020,35 +5109,57 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000081"
+ "@value": "nrel00001167"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000991",
+ "@id": "urn:nrel_example/nrel00000657",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000779"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000912"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00001194"
+ "@id": "urn:nrel_example/nrel00000767"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001133"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000991"
+ "@value": "nrel00000657"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000883",
+ "@id": "urn:nrel_example/nrel00000208",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000208"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000301",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
@@ -5057,281 +5168,297 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000883"
+ "@value": "nrel00000301"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000508",
+ "@id": "urn:nrel_example/nrel00000797",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:nrel_example/nrel00001023"
+ }
+ ],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000508"
+ "@value": "nrel00000797"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000429",
+ "@id": "urn:nrel_example/nrel00000374",
"@type": [
- "http://data.ashrae.org/standard223#Filter"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000158"
+ "@id": "urn:nrel_example/nrel00000001"
},
{
- "@id": "urn:nrel_example/nrel00000940"
+ "@id": "urn:nrel_example/nrel00000219"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000250"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000429"
+ "@value": "nrel00000374"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000138",
+ "@id": "urn:nrel_example/nrel00000570",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000138"
+ "@value": "nrel00000570"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001070",
+ "@id": "urn:nrel_example/nrel00001205",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ "@id": "urn:nrel_example/nrel00000504"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "urn:nrel_example/nrel00000263"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001070"
+ "@value": "nrel00001205"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001140",
+ "@id": "urn:nrel_example/nrel00000757",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#CoolingCoil"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
+ "@id": "urn:nrel_example/nrel00000629"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000872"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "urn:nrel_example/nrel00000006"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000015"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000423"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001112"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000008"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000545"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000999"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001084"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001288"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001140"
+ "@value": "nrel00000757"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001325",
+ "@id": "urn:nrel_example/nrel00000609",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000724"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000802"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/A"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001325"
+ "@value": "nrel00000609"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001292",
+ "@id": "urn:nrel_example/nrel00000812",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001300"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000147"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001292"
+ "@value": "nrel00000812"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000491",
+ "@id": "urn:nrel_example/nrel00000653",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000864"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000491"
+ "@value": "nrel00000653"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000442",
+ "@id": "urn:nrel_example/nrel00000154",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "http://qudt.org/vocab/unit/IN_H2O"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000442"
+ "@value": "nrel00000154"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001330",
+ "@id": "urn:nrel_example/nrel00000557",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000846"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000121"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000576"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001330"
+ "@value": "nrel00000557"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000156",
+ "@id": "urn:nrel_example/nrel00001178",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/A"
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000156"
+ "@value": "nrel00001178"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001037",
+ "@id": "urn:nrel_example/nrel00000888",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000722"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000820"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001037"
+ "@value": "nrel00000888"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000671",
+ "@id": "urn:nrel_example/nrel00000525",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000671"
+ "@value": "nrel00000525"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001020",
+ "@id": "urn:nrel_example/nrel00000354",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -5342,119 +5469,96 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001020"
+ "@value": "nrel00000354"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001084",
+ "@id": "urn:nrel_example/nrel00000142",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:nrel_example/nrel00000948"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:nrel_example/nrel00000641"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001084"
+ "@value": "nrel00000142"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000552",
+ "@id": "urn:nrel_example/nrel00001035",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000552"
+ "@value": "nrel00001035"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000636",
+ "@id": "urn:nrel_example/nrel00000229",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000636"
+ "@value": "nrel00000229"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001061",
+ "@id": "urn:nrel_example/nrel00000714",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001061"
+ "@value": "nrel00000714"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001093",
+ "@id": "urn:nrel_example/nrel00000480",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
- }
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/unit/V"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000220"
+ },
{
- "@value": "nrel00001093"
+ "@id": "urn:nrel_example/nrel00000420"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000947",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -5463,117 +5567,112 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000947"
+ "@value": "nrel00000480"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000899",
+ "@id": "urn:nrel_example/nrel00000496",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000875"
+ "@id": "urn:nrel_example/nrel00000970"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00001272"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000899"
+ "@value": "nrel00000496"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001175",
+ "@id": "urn:nrel_example/nrel00000230",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
+ "@id": "urn:nrel_example/nrel00001194"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "urn:nrel_example/nrel00001022"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001175"
+ "@value": "nrel00000230"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000071",
+ "@id": "urn:nrel_example/nrel00001177",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/A"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000071"
+ "@value": "nrel00001177"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000692",
+ "@id": "urn:nrel_example/nrel00001299",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Frequency"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/HZ"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000692"
+ "@value": "nrel00001299"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000772",
+ "@id": "urn:nrel_example/nrel00000002",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000167"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000978"
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000772"
+ "@value": "nrel00000002"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000583",
+ "@id": "urn:nrel_example/nrel00000363",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
@@ -5584,184 +5683,240 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000583"
+ "@value": "nrel00000363"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001024",
+ "@id": "urn:nrel_example/nrel00000053",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#Fan"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000208"
+ "@id": "urn:nrel_example/nrel00000461"
},
{
- "@id": "urn:nrel_example/nrel00000947"
+ "@id": "urn:nrel_example/nrel00000931"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000012"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000492"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000550"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000562"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000566"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000572"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000607"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000648"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000877"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001075"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001093"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001024"
+ "@value": "nrel00000053"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000341",
+ "@id": "urn:nrel_example/nrel00000512",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000341"
+ "@value": "nrel00000512"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001095",
+ "@id": "urn:nrel_example/nrel00000298",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000668"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000046"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001095"
+ "@value": "nrel00000298"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000507",
+ "@id": "urn:nrel_example/nrel00001072",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000507"
+ "@value": "nrel00001072"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000230",
+ "@id": "urn:nrel_example/nrel00000396",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00001194"
+ "@id": "urn:nrel_example/nrel00000278"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000603"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001022"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000230"
+ "@value": "nrel00000396"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001227",
+ "@id": "urn:nrel_example/nrel00000484",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00000059"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@value": "nrel00001227"
+ "@id": "urn:nrel_example/nrel00000282"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000119",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00000113"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000119"
+ "@value": "nrel00000484"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001326",
+ "@id": "urn:nrel_example/nrel00000038",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#FanCoilUnit"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Energy"
+ "@id": "urn:nrel_example/nrel00000495"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000780"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001187"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW-HR"
+ "@id": "urn:nrel_example/nrel00000420"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001270"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000173"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000212"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000228"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000329"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000884"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasRole": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Cooling"
+ },
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001326"
+ "@value": "nrel00000038"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000363",
+ "@id": "urn:nrel_example/nrel00001260",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000363"
+ "@value": "nrel00001260"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000274",
+ "@id": "urn:nrel_example/nrel00001286",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -5777,157 +5932,186 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000274"
+ "@value": "nrel00001286"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000900",
+ "@id": "urn:nrel_example/nrel00000409",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Zone"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasDomainSpace": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Frequency"
+ "@id": "urn:nrel_example/nrel00000966"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://qudt.org/vocab/unit/HZ"
+ "@value": "nrel00000409"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001024",
+ "@type": [
+ "http://data.ashrae.org/standard223#Duct"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:nrel_example/nrel00000208"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000947"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000900"
+ "@value": "nrel00001024"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000440",
+ "@id": "urn:nrel_example/nrel00001032",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000440"
+ "@value": "nrel00001032"
}
]
},
{
- "@id": "http://data.ashrae.org/standard223#HeatRecoveryCoil",
- "http://www.w3.org/2000/01/rdf-schema#subClassOf": [
+ "@id": "urn:nrel_example/nrel00000430",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Coil"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000430"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000916",
+ "@id": "urn:nrel_example/nrel00000228",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000228"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001296",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000600"
+ "@id": "urn:nrel_example/nrel00001200"
}
],
"http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "urn:nrel_example/nrel00000114"
+ "@id": "urn:nrel_example/nrel00000241"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00001059"
+ "@id": "urn:nrel_example/nrel00000274"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000916"
+ "@value": "nrel00001296"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000644",
+ "@id": "urn:nrel_example/nrel00001141",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000644"
+ "@value": "nrel00001141"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000966",
+ "@id": "urn:nrel_example/nrel00000532",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000059"
- },
- {
- "@id": "urn:nrel_example/nrel00000098"
- },
- {
- "@id": "urn:nrel_example/nrel00000658"
- }
- ],
- "http://data.ashrae.org/standard223#hasDomain": [
- {
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000109"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000845"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000966"
+ "@value": "nrel00000532"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000837",
+ "@id": "urn:nrel_example/nrel00000358",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000837"
+ "@value": "nrel00000358"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000742",
+ "@id": "urn:nrel_example/nrel00001080",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -5936,96 +6120,91 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000742"
+ "@value": "nrel00001080"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000531",
+ "@id": "urn:nrel_example/nrel00001292",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00001023"
+ "@id": "urn:nrel_example/nrel00001300"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00001138"
+ "@id": "urn:nrel_example/nrel00000147"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000531"
+ "@value": "nrel00001292"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000404",
+ "@id": "urn:nrel_example/nrel00000082",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000404"
+ "@value": "nrel00000082"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000550",
+ "@id": "urn:nrel_example/nrel00000616",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Energy"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW-HR"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000550"
+ "@value": "nrel00000616"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000352",
+ "@id": "urn:nrel_example/nrel00000340",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "urn:nrel_example/nrel00000051"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:nrel_example/nrel00000202"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000352"
+ "@value": "nrel00000340"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000540",
+ "@id": "urn:nrel_example/nrel00000689",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
@@ -6036,300 +6215,284 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000540"
+ "@value": "nrel00000689"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000332",
+ "@id": "urn:nrel_example/nrel00000190",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000332"
+ "@value": "nrel00000190"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001100",
+ "@id": "urn:nrel_example/nrel00000100",
"@type": [
- "http://data.ashrae.org/standard223#HeatExchanger"
- ],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000449"
- },
- {
- "@id": "urn:nrel_example/nrel00001258"
- },
- {
- "@id": "urn:nrel_example/nrel00001263"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000261"
- },
- {
- "@id": "urn:nrel_example/nrel00000554"
- },
- {
- "@id": "urn:nrel_example/nrel00000577"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001180"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000687"
- },
- {
- "@id": "urn:nrel_example/nrel00000885"
- },
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00001179"
+ "@value": "nrel00000100"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000786",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Evaporator"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001100"
+ "@value": "nrel00000786"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000906",
+ "@id": "urn:nrel_example/nrel00000613",
"@type": [
"http://data.ashrae.org/standard223#Valve"
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000827"
+ "@id": "urn:nrel_example/nrel00000093"
},
{
- "@id": "urn:nrel_example/nrel00000852"
+ "@id": "urn:nrel_example/nrel00000894"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000422"
+ "@id": "urn:nrel_example/nrel00000952"
},
{
- "@id": "urn:nrel_example/nrel00000855"
+ "@id": "urn:nrel_example/nrel00001088"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000906"
+ "@value": "nrel00000613"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000385",
+ "@id": "urn:nrel_example/nrel00000488",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000385"
+ "@value": "nrel00000488"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000052",
+ "@id": "urn:nrel_example/nrel00000063",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000052"
+ "@value": "nrel00000063"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001006",
+ "@id": "urn:nrel_example/nrel00000460",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#HeatingCoil"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000300"
+ },
{
- "@value": "nrel00001006"
+ "@id": "urn:nrel_example/nrel00000817"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001162"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000130",
- "@type": [
- "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000380"
+ "@id": "urn:nrel_example/nrel00000065"
},
{
- "@id": "urn:nrel_example/nrel00000579"
+ "@id": "urn:nrel_example/nrel00001050"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001072"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001107"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000518"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000684"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000130"
+ "@value": "nrel00000460"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000704",
+ "@id": "urn:nrel_example/nrel00001045",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Frequency"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/HZ"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000704"
+ "@value": "nrel00001045"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000270",
+ "@id": "urn:nrel_example/nrel00001273",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Frequency"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/HZ"
+ "@id": "http://qudt.org/vocab/unit/KiloW"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000270"
+ "@value": "nrel00001273"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000178",
+ "@id": "urn:nrel_example/nrel00000793",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000178"
+ "@value": "nrel00000793"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000560",
+ "@id": "urn:nrel_example/nrel00000926",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Energy"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW-HR"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-FlowStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000560"
+ "@value": "nrel00000926"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000315",
+ "@id": "urn:nrel_example/nrel00000749",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:nrel_example/nrel00000715"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:nrel_example/nrel00000946"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000315"
+ "@value": "nrel00000749"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000224",
+ "@id": "urn:nrel_example/nrel00000614",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "http://qudt.org/vocab/unit/KiloW"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000224"
+ "@value": "nrel00000614"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000009",
+ "@id": "urn:nrel_example/nrel00000956",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -6345,173 +6508,165 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000009"
+ "@value": "nrel00000956"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000780",
+ "@id": "urn:nrel_example/nrel00001325",
"@type": [
- "http://data.ashrae.org/standard223#CoolingCoil"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000179"
+ "@id": "urn:nrel_example/nrel00000724"
},
{
- "@id": "urn:nrel_example/nrel00001015"
+ "@id": "urn:nrel_example/nrel00000802"
}
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000525"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000826"
- },
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00001043"
- },
+ "@value": "nrel00001325"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000357",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00001063"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000191"
- },
- {
- "@id": "urn:nrel_example/nrel00000394"
- },
- {
- "@id": "urn:nrel_example/nrel00000556"
- },
- {
- "@id": "urn:nrel_example/nrel00000592"
- },
- {
- "@id": "urn:nrel_example/nrel00001001"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00000780"
+ "@value": "nrel00000357"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000305",
+ "@id": "urn:nrel_example/nrel00000025",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000305"
+ "@value": "nrel00000025"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001130",
+ "@id": "urn:nrel_example/nrel00001176",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#HeatingCoil"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "urn:nrel_example/nrel00000137"
+ },
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000561"
+ },
{
- "@value": "nrel00001130"
+ "@id": "urn:nrel_example/nrel00001095"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000994",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:nrel_example/nrel00000625"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000668"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000810"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001102"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:nrel_example/nrel00000046"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000623"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000994"
+ "@value": "nrel00001176"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000211",
+ "@id": "urn:nrel_example/nrel00001043",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000211"
+ "@value": "nrel00001043"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001110",
+ "@id": "urn:nrel_example/nrel00000012",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001110"
+ "@value": "nrel00000012"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000299",
+ "@id": "urn:nrel_example/nrel00000465",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000299"
+ "@value": "nrel00000465"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000961",
+ "@id": "urn:nrel_example/nrel00000983",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -6522,67 +6677,62 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000961"
+ "@value": "nrel00000983"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000045",
+ "@id": "urn:nrel_example/nrel00001197",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000466"
+ },
{
- "@value": "nrel00000045"
+ "@id": "urn:nrel_example/nrel00000590"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000823",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:nrel_example/nrel00000499"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001306"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000823"
+ "@value": "nrel00001197"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000836",
+ "@id": "urn:nrel_example/nrel00000306",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000836"
+ "@value": "nrel00000306"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000979",
+ "@id": "urn:nrel_example/nrel00001170",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
@@ -6591,752 +6741,696 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000979"
+ "@value": "nrel00001170"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000344",
+ "@id": "urn:nrel_example/nrel00000262",
"@type": [
- "http://data.ashrae.org/standard223#Pump"
+ "http://data.ashrae.org/standard223#FanCoilUnit"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:nrel_example/nrel00000944"
+ "@id": "urn:nrel_example/nrel00000035"
},
{
- "@id": "urn:nrel_example/nrel00001210"
+ "@id": "urn:nrel_example/nrel00000505"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000729"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000145"
- },
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000170"
+ "@id": "urn:nrel_example/nrel00000597"
},
{
- "@id": "urn:nrel_example/nrel00000174"
- },
+ "@id": "urn:nrel_example/nrel00000724"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000384"
+ "@id": "urn:nrel_example/nrel00000070"
},
{
- "@id": "urn:nrel_example/nrel00000456"
+ "@id": "urn:nrel_example/nrel00000405"
},
{
- "@id": "urn:nrel_example/nrel00000468"
+ "@id": "urn:nrel_example/nrel00000551"
},
{
- "@id": "urn:nrel_example/nrel00000937"
+ "@id": "urn:nrel_example/nrel00000980"
},
{
- "@id": "urn:nrel_example/nrel00001081"
- },
+ "@id": "urn:nrel_example/nrel00001011"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "urn:nrel_example/nrel00001120"
+ "@id": "http://data.ashrae.org/standard223#Role-Cooling"
},
{
- "@id": "urn:nrel_example/nrel00001246"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000344"
+ "@value": "nrel00000262"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000019",
+ "@id": "urn:nrel_example/nrel00000455",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/Frequency"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/HZ"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000019"
+ "@value": "nrel00000455"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000658",
+ "@id": "urn:nrel_example/nrel00000694",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000658"
+ "@value": "nrel00000694"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000014",
+ "@id": "urn:nrel_example/nrel00001192",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000014"
+ "@value": "nrel00001192"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000430",
+ "@id": "urn:nrel_example/nrel00000349",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000430"
+ "@value": "nrel00000349"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001008",
+ "@id": "urn:nrel_example/nrel00001084",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000092"
- },
- {
- "@id": "urn:nrel_example/nrel00000400"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000454"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000017"
- },
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000305"
- },
- {
- "@id": "urn:nrel_example/nrel00000797"
- },
- {
- "@id": "urn:nrel_example/nrel00001144"
+ "@value": "nrel00001084"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000079",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000275"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000738"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001008"
+ "@value": "nrel00000079"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001222",
+ "@id": "urn:nrel_example/nrel00000387",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001222"
+ "@value": "nrel00000387"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001183",
+ "@id": "urn:nrel_example/nrel00000921",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001183"
+ "@value": "nrel00000921"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000830",
+ "@id": "urn:nrel_example/nrel00000386",
"@type": [
- "http://data.ashrae.org/standard223#Fan"
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000252"
- },
- {
- "@id": "urn:nrel_example/nrel00001159"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000238"
- },
- {
- "@id": "urn:nrel_example/nrel00000359"
- },
- {
- "@id": "urn:nrel_example/nrel00000427"
- },
- {
- "@id": "urn:nrel_example/nrel00000645"
- },
- {
- "@id": "urn:nrel_example/nrel00000791"
- },
- {
- "@id": "urn:nrel_example/nrel00000861"
- },
- {
- "@id": "urn:nrel_example/nrel00000880"
- },
- {
- "@id": "urn:nrel_example/nrel00000977"
- },
- {
- "@id": "urn:nrel_example/nrel00001019"
- },
- {
- "@id": "urn:nrel_example/nrel00001048"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001217"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000830"
+ "@value": "nrel00000386"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000625",
+ "@id": "urn:nrel_example/nrel00001129",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000625"
+ "@value": "nrel00001129"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000053",
+ "@id": "urn:nrel_example/nrel00000774",
"@type": [
- "http://data.ashrae.org/standard223#Fan"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000461"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000931"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000012"
- },
- {
- "@id": "urn:nrel_example/nrel00000492"
- },
- {
- "@id": "urn:nrel_example/nrel00000550"
- },
- {
- "@id": "urn:nrel_example/nrel00000562"
- },
- {
- "@id": "urn:nrel_example/nrel00000566"
- },
- {
- "@id": "urn:nrel_example/nrel00000572"
- },
- {
- "@id": "urn:nrel_example/nrel00000607"
- },
- {
- "@id": "urn:nrel_example/nrel00000648"
- },
- {
- "@id": "urn:nrel_example/nrel00000877"
- },
- {
- "@id": "urn:nrel_example/nrel00001075"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001093"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000053"
+ "@value": "nrel00000774"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001172",
+ "@id": "urn:nrel_example/nrel00000700",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001172"
+ "@value": "nrel00000700"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000069",
+ "@id": "urn:nrel_example/nrel00000813",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Duct"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:nrel_example/nrel00001107"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001302"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000069"
+ "@value": "nrel00000813"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000015",
+ "@id": "urn:nrel_example/nrel00000000",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000015"
+ "@value": "nrel00000000"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000922",
+ "@id": "urn:nrel_example/nrel00000925",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00000441"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000118"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000922"
+ "@value": "nrel00000925"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001150",
+ "@id": "urn:nrel_example/nrel00000993",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/A"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001150"
+ "@value": "nrel00000993"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000504",
+ "@id": "urn:nrel_example/nrel00000965",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:nrel_example/nrel00000080"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@value": "nrel00000504"
+ "@id": "urn:nrel_example/nrel00000859"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000620",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:nrel_example/nrel00000005"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000620"
+ "@value": "nrel00000965"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000065",
+ "@id": "urn:nrel_example/nrel00000718",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000948"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000065"
+ "@value": "nrel00000718"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000127",
+ "@id": "urn:nrel_example/nrel00000605",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000631"
- }
- ],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "@id": "urn:nrel_example/nrel00000151"
+ },
{
- "@id": "urn:nrel_example/nrel00000241"
+ "@id": "urn:nrel_example/nrel00001229"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001085"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000127"
+ "@value": "nrel00000605"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000794",
+ "@id": "urn:nrel_example/nrel00001020",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00001197"
- }
- ],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
- {
- "@id": "urn:nrel_example/nrel00001121"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001306"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000794"
+ "@value": "nrel00001020"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000514",
+ "@id": "urn:nrel_example/nrel00000998",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000465"
+ },
{
- "@value": "nrel00000514"
+ "@id": "urn:nrel_example/nrel00000786"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00001285",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:nrel_example/nrel00000207"
- }
- ],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001285"
+ "@value": "nrel00000998"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000860",
+ "@id": "urn:nrel_example/nrel00000501",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00000236"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@value": "nrel00000860"
+ "@id": "urn:nrel_example/nrel00001165"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000390",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000567"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000390"
+ "@value": "nrel00000501"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000536",
+ "@id": "urn:nrel_example/nrel00000327",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/A"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000536"
+ "@value": "nrel00000327"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000418",
+ "@id": "urn:nrel_example/nrel00000936",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000485"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000457"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000418"
+ "@value": "nrel00000936"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000676",
+ "@id": "urn:nrel_example/nrel00001209",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000676"
+ "@value": "nrel00001209"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000064",
+ "@id": "urn:nrel_example/nrel00000041",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/IN_H2O"
+ "@id": "http://qudt.org/vocab/unit/A"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000064"
+ "@value": "nrel00000041"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000730",
+ "@id": "urn:nrel_example/nrel00000524",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00000967"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000865"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000730"
+ "@value": "nrel00000524"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000243",
+ "@id": "urn:nrel_example/nrel00000361",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#CoolingCoil"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "urn:nrel_example/nrel00000313"
+ },
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:nrel_example/nrel00000870"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@value": "nrel00000243"
+ "@id": "urn:nrel_example/nrel00000030"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000704"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001034"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001264"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000928",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00000325"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000599"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000719"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000773"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001313"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000928"
+ "@value": "nrel00000361"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000163",
+ "@id": "urn:nrel_example/nrel00000464",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ "@id": "urn:nrel_example/nrel00000862"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "urn:nrel_example/nrel00000825"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000956"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000163"
+ "@value": "nrel00000464"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000954",
+ "@id": "urn:nrel_example/nrel00001195",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00000798"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000888"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000910"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001227"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000954"
+ "@value": "nrel00001195"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000970",
+ "@id": "urn:nrel_example/nrel00001161",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -7345,33 +7439,33 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000970"
+ "@value": "nrel00001161"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001066",
+ "@id": "urn:nrel_example/nrel00000624",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW"
+ "@id": "http://qudt.org/vocab/unit/A"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001066"
+ "@value": "nrel00000624"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000555",
+ "@id": "urn:nrel_example/nrel00000068",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -7387,113 +7481,133 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000555"
+ "@value": "nrel00000068"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000216",
+ "@id": "urn:nrel_example/nrel00000372",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:nrel_example/nrel00000893"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:nrel_example/nrel00000553"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000930"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000216"
+ "@value": "nrel00000372"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000525",
+ "@id": "urn:nrel_example/nrel00000046",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000525"
+ "@value": "nrel00000046"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000584",
+ "@id": "urn:nrel_example/nrel00001204",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000584"
+ "@value": "nrel00001204"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000062",
+ "@id": "urn:nrel_example/nrel00000107",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000514"
- },
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000913"
+ "@id": "urn:nrel_example/nrel00000875"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000601"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000793"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000062"
+ "@value": "nrel00000107"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001161",
+ "@id": "urn:nrel_example/nrel00000736",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000045"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000162"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasDomain": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00001014"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001295"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001161"
+ "@value": "nrel00000736"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000108",
+ "@id": "urn:nrel_example/nrel00000047",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
@@ -7504,94 +7618,115 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000108"
+ "@value": "nrel00000047"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000768",
+ "@id": "urn:nrel_example/nrel00000167",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00001047"
- },
- {
- "@id": "urn:nrel_example/nrel00001068"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000768"
+ "@value": "nrel00000167"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000697",
+ "@id": "urn:nrel_example/nrel00000039",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
+ "@id": "urn:nrel_example/nrel00001226"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "urn:nrel_example/nrel00000933"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000697"
+ "@value": "nrel00000039"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000834",
+ "@id": "urn:nrel_example/nrel00000061",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#CoolingCoil"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:nrel_example/nrel00000062"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001199"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "urn:nrel_example/nrel00000240"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000586"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000964"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001268"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000498"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000529"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000718"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001158"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001261"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000834"
+ "@value": "nrel00000061"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000377",
+ "@id": "urn:nrel_example/nrel00000880",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000377"
+ "@value": "nrel00000880"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000776",
+ "@id": "urn:nrel_example/nrel00000705",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -7602,54 +7737,44 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000776"
+ "@value": "nrel00000705"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000109",
+ "@id": "urn:nrel_example/nrel00000676",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000109"
+ "@value": "nrel00000676"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000369",
+ "@id": "urn:nrel_example/nrel00000108",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000441"
- }
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000758"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000369"
+ "@value": "nrel00000108"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000221",
+ "@id": "urn:nrel_example/nrel00001052",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -7658,35 +7783,35 @@
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:nrel_example/nrel00000967"
+ }
+ ],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000221"
+ "@value": "nrel00001052"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001167",
+ "@id": "urn:nrel_example/nrel00000579",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001167"
+ "@value": "nrel00000579"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000000",
+ "@id": "urn:nrel_example/nrel00000017",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -7697,415 +7822,424 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000000"
+ "@value": "nrel00000017"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000231",
+ "@id": "urn:nrel_example/nrel00000709",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000231"
+ "@value": "nrel00000709"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000226",
+ "@id": "urn:nrel_example/nrel00000445",
"@type": [
- "http://data.ashrae.org/standard223#CoolingCoil"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000031"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000371"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000063"
- },
- {
- "@id": "urn:nrel_example/nrel00000269"
- },
- {
- "@id": "urn:nrel_example/nrel00000663"
- },
- {
- "@id": "urn:nrel_example/nrel00001316"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000204"
- },
- {
- "@id": "urn:nrel_example/nrel00000213"
- },
- {
- "@id": "urn:nrel_example/nrel00000557"
- },
- {
- "@id": "urn:nrel_example/nrel00000803"
- },
- {
- "@id": "urn:nrel_example/nrel00001293"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00000226"
+ "@value": "nrel00000445"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000480",
+ "@id": "urn:nrel_example/nrel00001003",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000220"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000420"
+ "@id": "urn:nrel_example/nrel00000050"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000853"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000480"
+ "@value": "nrel00001003"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000118",
+ "@id": "urn:nrel_example/nrel00001090",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/IN_H2O"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000118"
+ "@value": "nrel00001090"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001026",
+ "@id": "urn:nrel_example/nrel00000237",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001026"
+ "@value": "nrel00000237"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000056",
+ "@id": "urn:nrel_example/nrel00001288",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000056"
+ "@value": "nrel00001288"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001005",
+ "@id": "urn:nrel_example/nrel00000009",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001005"
+ "@value": "nrel00000009"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001128",
+ "@id": "urn:nrel_example/nrel00000747",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
+ "@id": "urn:nrel_example/nrel00001023"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "urn:nrel_example/nrel00000710"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001128"
+ "@value": "nrel00000747"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000930",
+ "@id": "urn:nrel_example/nrel00000737",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000930"
+ "@value": "nrel00000737"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000726",
+ "@id": "urn:nrel_example/nrel00000077",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:nrel_example/nrel00000424"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000892"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000726"
+ "@value": "nrel00000077"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000313",
+ "@id": "urn:nrel_example/nrel00000932",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000296"
+ "@id": "urn:nrel_example/nrel00000207"
},
{
- "@id": "urn:nrel_example/nrel00000428"
+ "@id": "urn:nrel_example/nrel00001086"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000066"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001269"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000313"
+ "@value": "nrel00000932"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001293",
+ "@id": "urn:nrel_example/nrel00000371",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Pump"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:nrel_example/nrel00000723"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001275"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:nrel_example/nrel00000033"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000136"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000239"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000385"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000560"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000584"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000928"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001150"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001151"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001171"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001293"
+ "@value": "nrel00000371"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000054",
+ "@id": "urn:nrel_example/nrel00000205",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:nrel_example/nrel00000025"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000076"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:nrel_example/nrel00000194"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000299"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000054"
+ "@value": "nrel00000205"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000877",
+ "@id": "urn:nrel_example/nrel00000915",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000877"
+ "@value": "nrel00000915"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000174",
+ "@id": "urn:nrel_example/nrel00000232",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Frequency"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/HZ"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000174"
+ "@value": "nrel00000232"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000327",
+ "@id": "urn:nrel_example/nrel00000608",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
+ "@id": "urn:nrel_example/nrel00001265"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/A"
+ "@id": "urn:nrel_example/nrel00000809"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000327"
+ "@value": "nrel00000608"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000273",
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Overridden",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil"
- ],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000214"
- },
+ "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus",
+ "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000293"
+ "@language": "en",
+ "@value": "AlarmStatus-Ok"
},
{
- "@id": "urn:nrel_example/nrel00000920"
+ "@language": "en",
+ "@value": "Override-Overridden"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001015",
+ "@type": [
+ "http://data.ashrae.org/standard223#Valve"
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000040"
- },
- {
- "@id": "urn:nrel_example/nrel00000638"
- },
- {
- "@id": "urn:nrel_example/nrel00000720"
+ "@id": "urn:nrel_example/nrel00000487"
},
{
- "@id": "urn:nrel_example/nrel00001069"
+ "@id": "urn:nrel_example/nrel00001099"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000412"
+ "@id": "urn:nrel_example/nrel00000024"
},
{
- "@id": "urn:nrel_example/nrel00000419"
+ "@id": "urn:nrel_example/nrel00000979"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000273"
+ "@value": "nrel00001015"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000718",
+ "@id": "urn:nrel_example/nrel00000684",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -8121,145 +8255,157 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000718"
+ "@value": "nrel00000684"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000196",
+ "@id": "urn:nrel_example/nrel00000250",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/IN_H2O"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000196"
+ "@value": "nrel00000250"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000955",
+ "@id": "urn:nrel_example/nrel00000772",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:nrel_example/nrel00000167"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000978"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000955"
+ "@value": "nrel00000772"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000185",
+ "@id": "urn:nrel_example/nrel00000710",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/A"
+ "@id": "http://qudt.org/vocab/unit/IN_H2O"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000185"
+ "@value": "nrel00000710"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001123",
+ "@id": "urn:nrel_example/nrel00001285",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:nrel_example/nrel00000207"
+ }
+ ],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001123"
+ "@value": "nrel00001285"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001060",
+ "@id": "urn:nrel_example/nrel00000758",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001060"
+ "@value": "nrel00000758"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000763",
+ "@id": "urn:nrel_example/nrel00001143",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000512"
+ },
{
- "@value": "nrel00000763"
+ "@id": "urn:nrel_example/nrel00001193"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000716",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000716"
+ "@value": "nrel00001143"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000043",
+ "@id": "urn:nrel_example/nrel00001226",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000043"
+ "@value": "nrel00001226"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000879",
+ "@id": "urn:nrel_example/nrel00000762",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
@@ -8270,105 +8416,138 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000879"
+ "@value": "nrel00000762"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001112",
+ "@id": "urn:nrel_example/nrel00000798",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001112"
+ "@value": "nrel00000798"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000374",
+ "@id": "urn:nrel_example/nrel00000923",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000001"
- },
+ "@id": "urn:nrel_example/nrel00000642"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000219"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000067"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000923"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000065",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:nrel_example/nrel00000948"
+ }
+ ],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000374"
+ "@value": "nrel00000065"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000857",
+ "@id": "urn:nrel_example/nrel00000654",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000857"
+ "@value": "nrel00000654"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000106",
+ "@id": "urn:nrel_example/nrel00001001",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000106"
+ "@value": "nrel00001001"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001323",
+ "@id": "urn:nrel_example/nrel00000994",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001323"
+ "@value": "nrel00000994"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000476",
+ "@id": "urn:nrel_example/nrel00000520",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -8384,30 +8563,40 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000476"
+ "@value": "nrel00000520"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000643",
+ "@id": "urn:nrel_example/nrel00000010",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "urn:nrel_example/nrel00000818"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ {
+ "@id": "urn:nrel_example/nrel00000336"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000739"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000643"
+ "@value": "nrel00000010"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001319",
+ "@id": "urn:nrel_example/nrel00001060",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
@@ -8416,576 +8605,587 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001319"
+ "@value": "nrel00001060"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001273",
+ "@id": "urn:nrel_example/nrel00001184",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001273"
+ "@value": "nrel00001184"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000296",
+ "@id": "urn:nrel_example/nrel00001101",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Duct"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:nrel_example/nrel00000806"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000864"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000296"
+ "@value": "nrel00001101"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000781",
+ "@id": "urn:nrel_example/nrel00000066",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000781"
+ "@value": "nrel00000066"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000615",
+ "@id": "urn:nrel_example/nrel00000510",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000281"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000354"
+ "@id": "urn:nrel_example/nrel00000961"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000475"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000615"
+ "@value": "nrel00000510"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000438",
+ "@id": "urn:nrel_example/nrel00001075",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/A"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000438"
+ "@value": "nrel00001075"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000057",
+ "@id": "urn:nrel_example/nrel00001270",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000057"
+ "@value": "nrel00001270"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000105",
+ "@id": "urn:nrel_example/nrel00000842",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Frequency"
+ "@id": "urn:nrel_example/nrel00000939"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "http://qudt.org/vocab/unit/HZ"
+ "@id": "urn:nrel_example/nrel00000708"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00001090"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000105"
+ "@value": "nrel00000842"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000292",
+ "@id": "urn:nrel_example/nrel00000249",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000292"
+ "@value": "nrel00000249"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000732",
+ "@id": "urn:nrel_example/nrel00000839",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#CoolingCoil"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "urn:nrel_example/nrel00001092"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001115"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:nrel_example/nrel00000356"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000508"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001062"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001189"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000125"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000552"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000654"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001126"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001247"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000732"
+ "@value": "nrel00000839"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000241",
+ "@id": "urn:nrel_example/nrel00000782",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#HeatingCoil"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:nrel_example/nrel00000631"
+ "@id": "urn:nrel_example/nrel00000148"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000647"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001037"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "urn:nrel_example/nrel00000190"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000722"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001046"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001052"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000274"
+ "@id": "urn:nrel_example/nrel00000820"
},
{
- "@id": "urn:nrel_example/nrel00001283"
+ "@id": "urn:nrel_example/nrel00001067"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000241"
+ "@value": "nrel00000782"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001233",
+ "@id": "urn:nrel_example/nrel00001026",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001233"
+ "@value": "nrel00001026"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000136",
+ "@id": "urn:nrel_example/nrel00000872",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ "@id": "urn:nrel_example/nrel00001234"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001298"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW"
+ "@id": "urn:nrel_example/nrel00001209"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001251"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000136"
+ "@value": "nrel00000872"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000815",
+ "@id": "urn:nrel_example/nrel00001057",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00001033"
- },
- {
- "@id": "urn:nrel_example/nrel00001229"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000762"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001041"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000815"
+ "@value": "nrel00001057"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000641",
+ "@id": "urn:nrel_example/nrel00000373",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/IN_H2O"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000641"
+ "@value": "nrel00000373"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000734",
+ "@id": "urn:nrel_example/nrel00000277",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000075"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000740"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000734"
+ "@value": "nrel00000277"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000139",
+ "@id": "urn:nrel_example/nrel00000640",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
- {
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000139"
+ "@value": "nrel00000640"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000324",
+ "@id": "urn:nrel_example/nrel00000381",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#HeatingCoil"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:nrel_example/nrel00000961"
+ "@id": "urn:nrel_example/nrel00000049"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000582"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000657"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000064"
+ "@id": "urn:nrel_example/nrel00000165"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001040"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001074"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001279"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000175"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000571"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000324"
+ "@value": "nrel00000381"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001036",
+ "@id": "urn:nrel_example/nrel00000071",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000462"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001036"
+ "@value": "nrel00000071"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000383",
+ "@id": "urn:nrel_example/nrel00000971",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000430"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000795"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000383"
+ "@value": "nrel00000971"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000370",
+ "@id": "urn:nrel_example/nrel00000345",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000370"
+ "@value": "nrel00000345"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000411",
+ "@id": "urn:nrel_example/nrel00000448",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000411"
+ "@value": "nrel00000448"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000112",
+ "@id": "urn:nrel_example/nrel00001059",
"@type": [
- "http://data.ashrae.org/standard223#Pump"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000407"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000621"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000316"
- },
- {
- "@id": "urn:nrel_example/nrel00000455"
- },
- {
- "@id": "urn:nrel_example/nrel00000506"
- },
- {
- "@id": "urn:nrel_example/nrel00000536"
- },
- {
- "@id": "urn:nrel_example/nrel00000583"
- },
- {
- "@id": "urn:nrel_example/nrel00000666"
- },
- {
- "@id": "urn:nrel_example/nrel00000721"
- },
- {
- "@id": "urn:nrel_example/nrel00000764"
- },
- {
- "@id": "urn:nrel_example/nrel00000851"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001103"
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000112"
+ "@value": "nrel00001059"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000838",
+ "@id": "urn:nrel_example/nrel00000476",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000399"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000714"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/A"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000838"
+ "@value": "nrel00000476"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000553",
+ "@id": "urn:nrel_example/nrel00000703",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#Damper"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000649"
+ "@id": "urn:nrel_example/nrel00000215"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001108"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000555"
+ "@id": "urn:nrel_example/nrel00000698"
},
{
- "@id": "urn:nrel_example/nrel00000930"
+ "@id": "urn:nrel_example/nrel00001188"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000553"
+ "@value": "nrel00000703"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000042",
+ "@id": "urn:nrel_example/nrel00000263",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/IN_H2O"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00000042"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000686",
- "@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000967"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
- {
- "@id": "urn:nrel_example/nrel00000176"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000686"
+ "@value": "nrel00000263"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001067",
+ "@id": "urn:nrel_example/nrel00000176",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -9001,28 +9201,28 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001067"
+ "@value": "nrel00000176"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000439",
+ "@id": "urn:nrel_example/nrel00000415",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000439"
+ "@value": "nrel00000415"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000387",
+ "@id": "urn:nrel_example/nrel00000257",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
@@ -9033,320 +9233,275 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000387"
+ "@value": "nrel00000257"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000175",
+ "@id": "urn:nrel_example/nrel00000945",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/KiloW"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000175"
+ "@value": "nrel00000945"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001145",
+ "@id": "urn:nrel_example/nrel00000668",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001145"
+ "@value": "nrel00000668"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000356",
+ "@id": "urn:nrel_example/nrel00000400",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:nrel_example/nrel00000305"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000738"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000356"
+ "@value": "nrel00000400"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000599",
+ "@id": "urn:nrel_example/nrel00000702",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000599"
+ "@value": "nrel00000702"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000198",
+ "@id": "urn:nrel_example/nrel00000324",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:nrel_example/nrel00000961"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000064"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000198"
+ "@value": "nrel00000324"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001220",
+ "@id": "urn:nrel_example/nrel00001036",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:nrel_example/nrel00000462"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001220"
+ "@value": "nrel00001036"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001055",
+ "@id": "urn:nrel_example/nrel00001221",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Energy"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW-HR"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00001055"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000210",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-FlowStatus"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000210"
+ "@value": "nrel00001221"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000835",
+ "@id": "urn:nrel_example/nrel00000886",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Energy"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW-HR"
+ "@id": "http://qudt.org/vocab/unit/A"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000835"
+ "@value": "nrel00000886"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000808",
+ "@id": "urn:nrel_example/nrel00001169",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:nrel_example/nrel00000635"
+ }
+ ],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000808"
+ "@value": "nrel00001169"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000350",
+ "@id": "urn:nrel_example/nrel00000959",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000986"
- }
- ],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
- {
- "@id": "urn:nrel_example/nrel00000160"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000225"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000350"
+ "@value": "nrel00000959"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000516",
+ "@id": "urn:nrel_example/nrel00000271",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000516"
+ "@value": "nrel00000271"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001003",
+ "@id": "urn:nrel_example/nrel00000881",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000050"
+ "@id": "urn:nrel_example/nrel00001194"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00000853"
+ "@id": "urn:nrel_example/nrel00000544"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001003"
+ "@value": "nrel00000881"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000242",
+ "@id": "urn:nrel_example/nrel00000946",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Frequency"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/HZ"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00000242"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000434",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000434"
+ "@value": "nrel00000946"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000893",
+ "@id": "urn:nrel_example/nrel00000701",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00001025"
+ },
{
- "@value": "nrel00000893"
+ "@id": "urn:nrel_example/nrel00001203"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00001242",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -9355,33 +9510,12 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001242"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000886",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
- {
- "@id": "http://qudt.org/vocab/unit/A"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00000886"
+ "@value": "nrel00000701"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000384",
+ "@id": "urn:nrel_example/nrel00000692",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -9397,28 +9531,12 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000384"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000986",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00000986"
+ "@value": "nrel00000692"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000674",
+ "@id": "urn:nrel_example/nrel00000977",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
@@ -9429,12 +9547,12 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000674"
+ "@value": "nrel00000977"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000212",
+ "@id": "urn:nrel_example/nrel00000419",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -9450,123 +9568,107 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000212"
+ "@value": "nrel00000419"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001257",
+ "@id": "urn:nrel_example/nrel00000799",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#HeatingCoil"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
+ "@id": "urn:nrel_example/nrel00000217"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000613"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001292"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/unit/A"
+ "@id": "urn:nrel_example/nrel00000161"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001056"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001183"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001300"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000147"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000565"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001257"
+ "@value": "nrel00000799"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001263",
+ "@id": "urn:nrel_example/nrel00000449",
"@type": [
- "http://data.ashrae.org/standard223#Equipment"
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00001263"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000280",
- "@type": [
- "http://data.ashrae.org/standard223#FanCoilUnit"
- ],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000003"
- },
- {
- "@id": "urn:nrel_example/nrel00000055"
- },
- {
- "@id": "urn:nrel_example/nrel00000848"
- }
+ "http://data.ashrae.org/standard223#Pump"
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000278"
+ "@id": "urn:nrel_example/nrel00000784"
},
{
- "@id": "urn:nrel_example/nrel00001157"
+ "@id": "urn:nrel_example/nrel00001129"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000988"
+ "@id": "urn:nrel_example/nrel00000224"
},
{
- "@id": "urn:nrel_example/nrel00001152"
+ "@id": "urn:nrel_example/nrel00000387"
},
{
- "@id": "urn:nrel_example/nrel00001204"
+ "@id": "urn:nrel_example/nrel00000458"
},
{
- "@id": "urn:nrel_example/nrel00001244"
+ "@id": "urn:nrel_example/nrel00000664"
},
{
- "@id": "urn:nrel_example/nrel00001282"
- }
- ],
- "http://data.ashrae.org/standard223#hasRole": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Cooling"
+ "@id": "urn:nrel_example/nrel00000692"
},
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000750"
+ },
{
- "@value": "nrel00000280"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000771",
- "@type": [
- "http://data.ashrae.org/standard223#Filter"
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "@id": "urn:nrel_example/nrel00000871"
+ },
{
- "@id": "urn:nrel_example/nrel00000307"
+ "@id": "urn:nrel_example/nrel00001222"
},
{
- "@id": "urn:nrel_example/nrel00000699"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "@id": "urn:nrel_example/nrel00001289"
+ },
{
- "@id": "urn:nrel_example/nrel00000154"
+ "@id": "urn:nrel_example/nrel00001326"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000771"
+ "@value": "nrel00000449"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001313",
+ "@id": "urn:nrel_example/nrel00001212",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -9582,402 +9684,441 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001313"
+ "@value": "nrel00001212"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001094",
+ "@id": "urn:nrel_example/nrel00001118",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Energy"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/KiloW-HR"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001094"
+ "@value": "nrel00001118"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000647",
+ "@id": "urn:nrel_example/nrel00000547",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000150"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000836"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000052"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000360"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000647"
+ "@value": "nrel00000547"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000932",
+ "@id": "urn:nrel_example/nrel00001128",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000207"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001086"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000932"
+ "@value": "nrel00001128"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000740",
+ "@id": "urn:nrel_example/nrel00000341",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000740"
+ "@value": "nrel00000341"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000436",
+ "@id": "urn:nrel_example/nrel00000538",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00000439"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ {
+ "@id": "urn:nrel_example/nrel00000114"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000477"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000436"
+ "@value": "nrel00000538"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000051",
+ "@id": "urn:nrel_example/nrel00000022",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Duct"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:nrel_example/nrel00000190"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000366"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000051"
+ "@value": "nrel00000022"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000793",
+ "@id": "urn:nrel_example/nrel00000101",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00000736"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ {
+ "@id": "urn:nrel_example/nrel00000969"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00001014"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000793"
+ "@value": "nrel00000101"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000847",
+ "@id": "urn:nrel_example/nrel00000665",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000847"
+ "@value": "nrel00000665"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000506",
+ "@id": "urn:nrel_example/nrel00001275",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/A"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000506"
+ "@value": "nrel00001275"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000308",
+ "@id": "urn:nrel_example/nrel00001019",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000308"
+ "@value": "nrel00001019"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000330",
+ "@id": "urn:nrel_example/nrel00000940",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:nrel_example/nrel00000050"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000330"
+ "@value": "nrel00000940"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000662",
+ "@id": "urn:nrel_example/nrel00000030",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000662"
+ "@value": "nrel00000030"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000743",
+ "@id": "urn:nrel_example/nrel00000569",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000743"
+ "@value": "nrel00000569"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000800",
+ "@id": "urn:nrel_example/nrel00000540",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00001064"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000500"
+ "@value": "nrel00000540"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001215",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000216"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000800"
+ "@value": "nrel00001215"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001031",
+ "@id": "urn:nrel_example/nrel00000040",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Energy"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW-HR"
+ "@value": "nrel00000040"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000590",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001031"
+ "@value": "nrel00000590"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000985",
+ "@id": "urn:nrel_example/nrel00000328",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ "@id": "urn:nrel_example/nrel00000306"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001262"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/IN_H2O"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000985"
+ "@value": "nrel00000328"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000959",
+ "@id": "urn:nrel_example/nrel00000442",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000959"
+ "@value": "nrel00000442"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000597",
+ "@id": "urn:nrel_example/nrel00000181",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000597"
+ "@value": "nrel00000181"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001134",
+ "@id": "urn:nrel_example/nrel00000013",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001134"
+ "@value": "nrel00000013"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000422",
+ "@id": "urn:nrel_example/nrel00001327",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
@@ -9986,12 +10127,12 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000422"
+ "@value": "nrel00001327"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000419",
+ "@id": "urn:nrel_example/nrel00000203",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -10007,12 +10148,12 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000419"
+ "@value": "nrel00000203"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000264",
+ "@id": "urn:nrel_example/nrel00000120",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -10023,254 +10164,134 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000264"
+ "@value": "nrel00000120"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001069",
+ "@id": "urn:nrel_example/nrel00000843",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001069"
+ "@value": "nrel00000843"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001308",
- "@type": [
- "http://data.ashrae.org/standard223#Fan"
- ],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000291"
- },
- {
- "@id": "urn:nrel_example/nrel00000496"
- }
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000970"
- },
- {
- "@id": "urn:nrel_example/nrel00001207"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000283"
- },
- {
- "@id": "urn:nrel_example/nrel00000651"
- },
- {
- "@id": "urn:nrel_example/nrel00000661"
- },
- {
- "@id": "urn:nrel_example/nrel00000674"
- },
- {
- "@id": "urn:nrel_example/nrel00000811"
- },
- {
- "@id": "urn:nrel_example/nrel00000963"
- },
- {
- "@id": "urn:nrel_example/nrel00001016"
- },
- {
- "@id": "urn:nrel_example/nrel00001132"
- },
- {
- "@id": "urn:nrel_example/nrel00001272"
- },
- {
- "@id": "urn:nrel_example/nrel00001273"
- },
- {
- "@id": "urn:nrel_example/nrel00001331"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "http://data.ashrae.org/standard223#HeatRecoveryCoil",
+ "http://www.w3.org/2000/01/rdf-schema#subClassOf": [
{
- "@value": "nrel00001308"
+ "@id": "http://data.ashrae.org/standard223#Coil"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000568",
+ "@id": "urn:nrel_example/nrel00001044",
"@type": [
- "http://data.ashrae.org/standard223#Fan"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000898"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00001051"
+ "@id": "urn:nrel_example/nrel00000364"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000197"
- },
- {
- "@id": "urn:nrel_example/nrel00000292"
- },
- {
- "@id": "urn:nrel_example/nrel00000402"
- },
- {
- "@id": "urn:nrel_example/nrel00000636"
- },
- {
- "@id": "urn:nrel_example/nrel00000697"
- },
- {
- "@id": "urn:nrel_example/nrel00000832"
- },
- {
- "@id": "urn:nrel_example/nrel00000945"
- },
- {
- "@id": "urn:nrel_example/nrel00000981"
- },
- {
- "@id": "urn:nrel_example/nrel00001058"
- },
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "urn:nrel_example/nrel00001106"
- },
+ "@id": "urn:nrel_example/nrel00000553"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00001201"
+ "@id": "urn:nrel_example/nrel00000555"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000568"
+ "@value": "nrel00001044"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000190",
+ "@id": "urn:nrel_example/nrel00000852",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000190"
+ "@value": "nrel00000852"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000267",
+ "@id": "urn:nrel_example/nrel00000990",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@value": "nrel00000267"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000449",
- "@type": [
- "http://data.ashrae.org/standard223#Pump"
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000784"
- },
- {
- "@id": "urn:nrel_example/nrel00001129"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000224"
- },
- {
- "@id": "urn:nrel_example/nrel00000387"
- },
- {
- "@id": "urn:nrel_example/nrel00000458"
- },
- {
- "@id": "urn:nrel_example/nrel00000664"
- },
- {
- "@id": "urn:nrel_example/nrel00000692"
- },
- {
- "@id": "urn:nrel_example/nrel00000750"
- },
- {
- "@id": "urn:nrel_example/nrel00000871"
- },
- {
- "@id": "urn:nrel_example/nrel00001222"
- },
- {
- "@id": "urn:nrel_example/nrel00001289"
- },
- {
- "@id": "urn:nrel_example/nrel00001326"
+ "@id": "http://qudt.org/vocab/unit/KiloW"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000449"
+ "@value": "nrel00000990"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000945",
+ "@id": "urn:nrel_example/nrel00000417",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000945"
+ "@value": "nrel00000417"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000577",
+ "@id": "urn:nrel_example/nrel00000615",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000891"
+ "@id": "urn:nrel_example/nrel00000281"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000354"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -10278,188 +10299,166 @@
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000687"
- }
- ],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000577"
+ "@value": "nrel00000615"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000281",
+ "@id": "urn:nrel_example/nrel00000752",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@value": "nrel00000281"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00001032",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001032"
+ "@value": "nrel00000752"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001253",
+ "@id": "urn:nrel_example/nrel00001038",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ "@id": "urn:nrel_example/nrel00000676"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW"
+ "@id": "urn:nrel_example/nrel00000203"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001253"
+ "@value": "nrel00001038"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001264",
+ "@id": "urn:nrel_example/nrel00000549",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000050"
+ },
{
- "@value": "nrel00001264"
+ "@id": "urn:nrel_example/nrel00000760"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000415",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000415"
+ "@value": "nrel00000549"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000187",
+ "@id": "urn:nrel_example/nrel00000007",
"@type": [
- "http://data.ashrae.org/standard223#TerminalUnit"
+ "http://data.ashrae.org/standard223#HeatingCoil"
],
"http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:nrel_example/nrel00000205"
- },
- {
- "@id": "urn:nrel_example/nrel00000273"
- },
- {
- "@id": "urn:nrel_example/nrel00000369"
+ "@id": "urn:nrel_example/nrel00000383"
},
{
- "@id": "urn:nrel_example/nrel00000925"
+ "@id": "urn:nrel_example/nrel00000749"
},
{
- "@id": "urn:nrel_example/nrel00001315"
+ "@id": "urn:nrel_example/nrel00001042"
}
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000441"
+ "@id": "urn:nrel_example/nrel00000430"
},
{
- "@id": "urn:nrel_example/nrel00001047"
+ "@id": "urn:nrel_example/nrel00000715"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000903"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001256"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000118"
- },
- {
- "@id": "urn:nrel_example/nrel00000132"
+ "@id": "urn:nrel_example/nrel00000795"
},
{
- "@id": "urn:nrel_example/nrel00000758"
+ "@id": "urn:nrel_example/nrel00000946"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000187"
+ "@value": "nrel00000007"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000498",
+ "@id": "urn:nrel_example/nrel00001073",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-FlowStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000498"
+ "@value": "nrel00001073"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001209",
+ "@id": "urn:nrel_example/nrel00000322",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00001259"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ {
+ "@id": "urn:nrel_example/nrel00000500"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00001168"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001209"
+ "@value": "nrel00000322"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000826",
+ "@id": "urn:nrel_example/nrel00000964",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -10470,12 +10469,12 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000826"
+ "@value": "nrel00000964"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000778",
+ "@id": "urn:nrel_example/nrel00000636",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -10491,36 +10490,33 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000778"
+ "@value": "nrel00000636"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000891",
+ "@id": "urn:nrel_example/nrel00000686",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000158"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000577"
+ "@id": "urn:nrel_example/nrel00000967"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000176"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000891"
+ "@value": "nrel00000686"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000006",
+ "@id": "urn:nrel_example/nrel00001040",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -10531,70 +10527,72 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000006"
+ "@value": "nrel00001040"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000337",
+ "@id": "urn:nrel_example/nrel00000245",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000469"
- },
- {
- "@id": "urn:nrel_example/nrel00000509"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000119"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000671"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000337"
+ "@value": "nrel00000245"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000527",
+ "@id": "urn:nrel_example/nrel00000738",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000527"
+ "@value": "nrel00000738"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000396",
+ "@id": "urn:nrel_example/nrel00001168",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000278"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000603"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00001168"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001159",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -10603,67 +10601,94 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000396"
+ "@value": "nrel00001159"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001280",
+ "@id": "urn:nrel_example/nrel00000337",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:nrel_example/nrel00000469"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000509"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:nrel_example/nrel00000119"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000671"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001280"
+ "@value": "nrel00000337"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001213",
+ "@id": "urn:nrel_example/nrel00001173",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ "@id": "http://qudt.org/vocab/quantitykind/Energy"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/IN_H2O"
+ "@id": "http://qudt.org/vocab/unit/KiloW-HR"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001213"
+ "@value": "nrel00001173"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001096",
+ "@id": "urn:nrel_example/nrel00000004",
"@type": [
- "http://data.ashrae.org/standard223#Junction"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000265"
- },
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000876"
- },
+ "@value": "nrel00000004"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000962",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00001135"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000962"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000625",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -10672,456 +10697,555 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001096"
+ "@value": "nrel00000625"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001089",
+ "@id": "urn:nrel_example/nrel00000773",
"@type": [
- "http://data.ashrae.org/standard223#HeatRecoveryCoil"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000351"
- },
- {
- "@id": "urn:nrel_example/nrel00000618"
- },
- {
- "@id": "urn:nrel_example/nrel00000821"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001304"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000315"
- },
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000368"
- },
+ "@value": "nrel00000773"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001002",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000431"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000488"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001089"
+ "@value": "nrel00001002"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001092",
+ "@id": "urn:nrel_example/nrel00000274",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000539"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000763"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000436"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001225"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001092"
+ "@value": "nrel00000274"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000953",
+ "@id": "urn:nrel_example/nrel00000329",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000953"
+ "@value": "nrel00000329"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000342",
+ "@id": "urn:nrel_example/nrel00000659",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000967"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00001221"
+ "@value": "nrel00000659"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000440",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ {
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000342"
+ "@value": "nrel00000440"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001010",
+ "@id": "urn:nrel_example/nrel00001196",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001010"
+ "@value": "nrel00001196"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001320",
+ "@id": "urn:nrel_example/nrel00000090",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000792"
+ "@id": "urn:nrel_example/nrel00000466"
}
],
"http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "urn:nrel_example/nrel00000464"
+ "@id": "urn:nrel_example/nrel00001121"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00000825"
+ "@id": "urn:nrel_example/nrel00000068"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001320"
+ "@value": "nrel00000090"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000663",
+ "@id": "urn:nrel_example/nrel00000634",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000663"
+ "@value": "nrel00000634"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000259",
+ "@id": "urn:nrel_example/nrel00000289",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Frequency"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/HZ"
+ "@id": "http://qudt.org/vocab/unit/A"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000259"
+ "@value": "nrel00000289"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000084",
+ "@id": "urn:nrel_example/nrel00000822",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000133"
- },
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000593"
+ "@id": "urn:nrel_example/nrel00000355"
},
{
- "@id": "urn:nrel_example/nrel00000772"
+ "@id": "urn:nrel_example/nrel00000438"
}
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000151"
- },
- {
- "@id": "urn:nrel_example/nrel00000167"
- },
- {
- "@id": "urn:nrel_example/nrel00000432"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000991"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000978"
- },
+ "@value": "nrel00000822"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000161",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001235"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000084"
+ "@value": "nrel00000161"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000503",
+ "@id": "urn:nrel_example/nrel00001265",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000649"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000553"
+ "@value": "nrel00001265"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001183",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001178"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000503"
+ "@value": "nrel00001183"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001179",
+ "@id": "urn:nrel_example/nrel00001174",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Fan"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ "@id": "urn:nrel_example/nrel00000588"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001294"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "urn:nrel_example/nrel00000020"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000029"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000257"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000295"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000569"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000650"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000796"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000857"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000890"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001076"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001154"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001179"
+ "@value": "nrel00001174"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001206",
+ "@id": "urn:nrel_example/nrel00000351",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ "@id": "urn:nrel_example/nrel00000172"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001206"
+ "@value": "nrel00000351"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000098",
+ "@id": "urn:nrel_example/nrel00000788",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000098"
+ "@value": "nrel00000788"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000538",
+ "@id": "urn:nrel_example/nrel00000828",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000439"
+ "@id": "urn:nrel_example/nrel00000251"
}
],
"http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "urn:nrel_example/nrel00000114"
+ "@id": "urn:nrel_example/nrel00000121"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00000477"
+ "@id": "urn:nrel_example/nrel00000071"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000538"
+ "@value": "nrel00000828"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000660",
+ "@id": "urn:nrel_example/nrel00001179",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000660"
+ "@value": "nrel00001179"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000997",
+ "@id": "urn:nrel_example/nrel00001263",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#Equipment"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@value": "nrel00001263"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000589",
+ "@type": [
+ "http://data.ashrae.org/standard223#Duct"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:nrel_example/nrel00000240"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000903"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000997"
+ "@value": "nrel00000589"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001146",
+ "@id": "urn:nrel_example/nrel00000555",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001146"
+ "@value": "nrel00000555"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000773",
+ "@id": "urn:nrel_example/nrel00000024",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ {
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000024"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000473",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ {
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000473"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000113",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000773"
+ "@value": "nrel00000113"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000251",
+ "@id": "urn:nrel_example/nrel00000671",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000251"
+ "@value": "nrel00000671"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001279",
+ "@id": "urn:nrel_example/nrel00000860",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001279"
+ "@value": "nrel00000860"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000621",
+ "@id": "urn:nrel_example/nrel00000407",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -11130,168 +11254,178 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000621"
+ "@value": "nrel00000407"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001199",
+ "@id": "urn:nrel_example/nrel00000587",
"@type": [
- "http://data.ashrae.org/standard223#Pump"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000096"
+ "@id": "urn:nrel_example/nrel00000745"
},
{
- "@id": "urn:nrel_example/nrel00001032"
+ "@id": "urn:nrel_example/nrel00000986"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000056"
- },
- {
- "@id": "urn:nrel_example/nrel00000242"
- },
- {
- "@id": "urn:nrel_example/nrel00000277"
- },
- {
- "@id": "urn:nrel_example/nrel00000289"
- },
- {
- "@id": "urn:nrel_example/nrel00000452"
- },
- {
- "@id": "urn:nrel_example/nrel00000559"
- },
- {
- "@id": "urn:nrel_example/nrel00000929"
- },
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:nrel_example/nrel00001028"
- },
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00001066"
+ "@id": "urn:nrel_example/nrel00000433"
},
{
- "@id": "urn:nrel_example/nrel00001224"
+ "@id": "urn:nrel_example/nrel00000844"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001199"
+ "@value": "nrel00000587"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000028",
+ "@id": "urn:nrel_example/nrel00000887",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:nrel_example/nrel00001311"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:nrel_example/nrel00000575"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000028"
+ "@value": "nrel00000887"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000950",
+ "@id": "urn:nrel_example/nrel00000095",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#TerminalUnit"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000168"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000312"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000497"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000608"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000799"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "urn:nrel_example/nrel00000227"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001265"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000042"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000726"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000809"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000950"
+ "@value": "nrel00000095"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000892",
+ "@id": "urn:nrel_example/nrel00001121",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "urn:nrel_example/nrel00000077"
+ "@id": "urn:nrel_example/nrel00001197"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000009"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000068"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000892"
+ "@value": "nrel00001121"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000816",
+ "@id": "urn:nrel_example/nrel00000895",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00001125"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000500"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000002"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000816"
+ "@value": "nrel00000895"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000521",
+ "@id": "urn:nrel_example/nrel00000028",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000354"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000139"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000521"
+ "@value": "nrel00000028"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000074",
+ "@id": "urn:nrel_example/nrel00000986",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -11302,216 +11436,205 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000074"
+ "@value": "nrel00000986"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000539",
+ "@id": "urn:nrel_example/nrel00001074",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000539"
+ "@value": "nrel00001074"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000495",
+ "@id": "urn:nrel_example/nrel00000672",
"@type": [
- "http://data.ashrae.org/standard223#Fan"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000331"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001111"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000270"
- },
- {
- "@id": "urn:nrel_example/nrel00000476"
- },
- {
- "@id": "urn:nrel_example/nrel00000523"
- },
- {
- "@id": "urn:nrel_example/nrel00000543"
- },
- {
- "@id": "urn:nrel_example/nrel00000706"
- },
- {
- "@id": "urn:nrel_example/nrel00000713"
- },
- {
- "@id": "urn:nrel_example/nrel00000730"
- },
- {
- "@id": "urn:nrel_example/nrel00000819"
- },
- {
- "@id": "urn:nrel_example/nrel00000831"
- },
- {
- "@id": "urn:nrel_example/nrel00001000"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001039"
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000495"
+ "@value": "nrel00000672"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000353",
+ "@id": "urn:nrel_example/nrel00001156",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:nrel_example/nrel00000198"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000578"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000788"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001006"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000353"
+ "@value": "nrel00001156"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000191",
+ "@id": "urn:nrel_example/nrel00001241",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000191"
+ "@value": "nrel00001241"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001275",
+ "@id": "urn:nrel_example/nrel00000097",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001275"
+ "@value": "nrel00000097"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000494",
+ "@id": "urn:nrel_example/nrel00000092",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00001023"
+ "@id": "urn:nrel_example/nrel00000017"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00000081"
+ "@id": "urn:nrel_example/nrel00000275"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000494"
+ "@value": "nrel00000092"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000165",
+ "@id": "urn:nrel_example/nrel00000158",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:nrel_example/nrel00000891"
+ }
+ ],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000165"
+ "@value": "nrel00000158"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000747",
+ "@id": "urn:nrel_example/nrel00000873",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001023"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000710"
+ "@value": "nrel00000873"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001319",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ {
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000747"
+ "@value": "nrel00001319"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000937",
+ "@id": "urn:nrel_example/nrel00000125",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/A"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000937"
+ "@value": "nrel00000125"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000287",
+ "@id": "urn:nrel_example/nrel00000596",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -11520,185 +11643,192 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000287"
+ "@value": "nrel00000596"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000214",
+ "@id": "urn:nrel_example/nrel00000348",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000408"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000526"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000395"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001170"
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000214"
+ "@value": "nrel00000348"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000314",
+ "@id": "urn:nrel_example/nrel00000303",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000314"
+ "@value": "nrel00000303"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000818",
+ "@id": "urn:nrel_example/nrel00000261",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000221"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001086"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@value": "nrel00000261"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001252",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000739"
- },
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00001130"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000818"
+ "@value": "nrel00001252"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000469",
+ "@id": "urn:nrel_example/nrel00000972",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/A"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000469"
+ "@value": "nrel00000972"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001238",
+ "@id": "urn:nrel_example/nrel00000011",
+ "@type": [
+ "http://www.w3.org/2002/07/owl#Ontology"
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000011"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001163",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/IN_H2O"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001238"
+ "@value": "nrel00001163"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001154",
+ "@id": "urn:nrel_example/nrel00000138",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-FlowStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001154"
+ "@value": "nrel00000138"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000446",
+ "@id": "urn:nrel_example/nrel00000898",
"@type": [
- "http://data.ashrae.org/standard223#Filter"
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000255"
- },
- {
- "@id": "urn:nrel_example/nrel00000892"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000564"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000446"
+ "@value": "nrel00000898"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000232",
+ "@id": "urn:nrel_example/nrel00001283",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Frequency"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/HZ"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000232"
+ "@value": "nrel00001283"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001245",
+ "@id": "urn:nrel_example/nrel00000851",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -11714,144 +11844,149 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001245"
+ "@value": "nrel00000851"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001004",
+ "@id": "urn:nrel_example/nrel00000831",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000221"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000336"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000680"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001004"
+ "@value": "nrel00000831"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000873",
+ "@id": "urn:nrel_example/nrel00000192",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000971"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001169"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00001060"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001327"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000873"
+ "@value": "nrel00000192"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000472",
+ "@id": "urn:nrel_example/nrel00000517",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00001241"
+ "@id": "urn:nrel_example/nrel00000307"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000618"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000256"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000472"
+ "@value": "nrel00000517"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001194",
+ "@id": "urn:nrel_example/nrel00001126",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@value": "nrel00001194"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00001126"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000629",
+ "@id": "urn:nrel_example/nrel00001175",
"@type": [
- "http://data.ashrae.org/standard223#Pump"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000318"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000393"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000105"
- },
- {
- "@id": "urn:nrel_example/nrel00000128"
- },
- {
- "@id": "urn:nrel_example/nrel00000218"
- },
- {
- "@id": "urn:nrel_example/nrel00000398"
- },
- {
- "@id": "urn:nrel_example/nrel00000519"
- },
- {
- "@id": "urn:nrel_example/nrel00000528"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000540"
- },
+ "@id": "http://qudt.org/vocab/unit/V"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000548"
- },
+ "@value": "nrel00001175"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000534",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000702"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001140"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000629"
+ "@value": "nrel00000534"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001269",
+ "@id": "urn:nrel_example/nrel00000753",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
@@ -11860,222 +11995,231 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001269"
+ "@value": "nrel00000753"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000073",
+ "@id": "urn:nrel_example/nrel00001216",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/V"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00001216"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000152",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000961"
+ "@id": "urn:nrel_example/nrel00000354"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00000332"
+ "@id": "urn:nrel_example/nrel00000823"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000073"
+ "@value": "nrel00000152"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000996",
+ "@id": "urn:nrel_example/nrel00000049",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:nrel_example/nrel00000165"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000175"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000996"
+ "@value": "nrel00000049"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000238",
+ "@id": "urn:nrel_example/nrel00000333",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Frequency"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/HZ"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000238"
+ "@value": "nrel00000333"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000628",
+ "@id": "urn:nrel_example/nrel00000987",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000677"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001262"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000632"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000716"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000628"
+ "@value": "nrel00000987"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000245",
+ "@id": "urn:nrel_example/nrel00000719",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000245"
+ "@value": "nrel00000719"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000101",
+ "@id": "urn:nrel_example/nrel00000920",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000736"
- }
- ],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
- {
- "@id": "urn:nrel_example/nrel00000969"
+ "@id": "urn:nrel_example/nrel00000638"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00001014"
+ "@id": "urn:nrel_example/nrel00000412"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000101"
+ "@value": "nrel00000920"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001127",
+ "@id": "urn:nrel_example/nrel00001213",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Frequency"
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/HZ"
+ "@id": "http://qudt.org/vocab/unit/IN_H2O"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001127"
+ "@value": "nrel00001213"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000724",
+ "@id": "urn:nrel_example/nrel00001116",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00001267"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@value": "nrel00000724"
+ "@id": "urn:nrel_example/nrel00001165"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00001104",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:nrel_example/nrel00000184"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001104"
+ "@value": "nrel00001116"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001177",
+ "@id": "urn:nrel_example/nrel00001154",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/A"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-FlowStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001177"
+ "@value": "nrel00001154"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000285",
+ "@id": "urn:nrel_example/nrel00001211",
"@type": [
"http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000059"
+ "@id": "urn:nrel_example/nrel00000406"
},
{
- "@id": "urn:nrel_example/nrel00001161"
+ "@id": "urn:nrel_example/nrel00000574"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -12085,70 +12229,70 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000285"
+ "@value": "nrel00001211"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001048",
+ "@id": "urn:nrel_example/nrel00000922",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001048"
+ "@value": "nrel00000922"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001074",
+ "@id": "urn:nrel_example/nrel00000418",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000485"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@value": "nrel00001074"
+ "@id": "urn:nrel_example/nrel00000457"
}
- ]
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000418"
+ }
+ ]
},
{
- "@id": "urn:nrel_example/nrel00001190",
+ "@id": "urn:nrel_example/nrel00000260",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000389"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000968"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001190"
+ "@value": "nrel00000260"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000417",
+ "@id": "urn:nrel_example/nrel00000191",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -12164,49 +12308,54 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000417"
+ "@value": "nrel00000191"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000018",
+ "@id": "urn:nrel_example/nrel00001138",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000018"
+ "@value": "nrel00001138"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001038",
+ "@id": "urn:nrel_example/nrel00000185",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000676"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000203"
+ "@id": "http://qudt.org/vocab/unit/A"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001038"
+ "@value": "nrel00000185"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001300",
+ "@id": "urn:nrel_example/nrel00000723",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -12217,210 +12366,244 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001300"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000608",
- "@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00001265"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
- {
- "@id": "urn:nrel_example/nrel00000809"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00000608"
+ "@value": "nrel00000723"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000530",
+ "@id": "urn:nrel_example/nrel00000572",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000530"
+ "@value": "nrel00000572"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000083",
+ "@id": "urn:nrel_example/nrel00000495",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
+ "http://data.ashrae.org/standard223#Fan"
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000437"
+ "@id": "urn:nrel_example/nrel00000331"
},
{
- "@id": "urn:nrel_example/nrel00001104"
+ "@id": "urn:nrel_example/nrel00001111"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00001026"
+ "@id": "urn:nrel_example/nrel00000270"
},
{
- "@id": "urn:nrel_example/nrel00001252"
+ "@id": "urn:nrel_example/nrel00000476"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000523"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000543"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000706"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000713"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000730"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000819"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000831"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001000"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001039"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000083"
+ "@value": "nrel00000495"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000665",
+ "@id": "urn:nrel_example/nrel00000272",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "http://qudt.org/vocab/unit/IN_H2O"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000665"
+ "@value": "nrel00000272"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000884",
+ "@id": "urn:nrel_example/nrel00001203",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000884"
+ "@value": "nrel00001203"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000017",
+ "@id": "urn:nrel_example/nrel00000792",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000017"
+ "@value": "nrel00000792"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000963",
+ "@id": "urn:nrel_example/nrel00001008",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#HeatingCoil"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
+ "@id": "urn:nrel_example/nrel00000092"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000400"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000454"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/unit/A"
+ "@id": "urn:nrel_example/nrel00000017"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000305"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000797"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001144"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000275"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000738"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000963"
+ "@value": "nrel00001008"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001295",
+ "@id": "urn:nrel_example/nrel00000823",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001295"
+ "@value": "nrel00000823"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000393",
+ "@id": "urn:nrel_example/nrel00001246",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/Energy"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/KiloW-HR"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000393"
+ "@value": "nrel00001246"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000710",
+ "@id": "urn:nrel_example/nrel00001329",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ "@id": "urn:nrel_example/nrel00000207"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/IN_H2O"
+ "@id": "urn:nrel_example/nrel00000709"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000710"
+ "@value": "nrel00001329"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000579",
+ "@id": "urn:nrel_example/nrel00001193",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -12429,137 +12612,198 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000579"
+ "@value": "nrel00001193"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000894",
+ "@id": "urn:nrel_example/nrel00001029",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:nrel_example/nrel00000388"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000673"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000894"
+ "@value": "nrel00001029"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000502",
+ "@id": "urn:nrel_example/nrel00000080",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000846"
+ "@id": "urn:nrel_example/nrel00000220"
},
{
- "@id": "urn:nrel_example/nrel00000948"
+ "@id": "urn:nrel_example/nrel00001105"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000005"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000319"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000502"
+ "@value": "nrel00000080"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001009",
+ "@id": "urn:nrel_example/nrel00001224",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001009"
+ "@value": "nrel00001224"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000570",
+ "@id": "urn:nrel_example/nrel00000099",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Fan"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:nrel_example/nrel00000297"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000541"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000036"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000181"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000210"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000259"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000304"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000375"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000609"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000690"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000744"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000954"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001147"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000570"
+ "@value": "nrel00000099"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000980",
+ "@id": "urn:nrel_example/nrel00000225",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000980"
+ "@value": "nrel00000225"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000379",
+ "@id": "urn:nrel_example/nrel00001028",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000379"
+ "@value": "nrel00001028"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000762",
+ "@id": "urn:nrel_example/nrel00001266",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00000321"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000936"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000762"
+ "@value": "nrel00001266"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000595",
+ "@id": "urn:nrel_example/nrel00001108",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -12570,54 +12814,57 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000595"
+ "@value": "nrel00001108"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001148",
+ "@id": "urn:nrel_example/nrel00000771",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Filter"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "urn:nrel_example/nrel00000307"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000699"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:nrel_example/nrel00000154"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001148"
+ "@value": "nrel00000771"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000890",
+ "@id": "urn:nrel_example/nrel00001151",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW"
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000890"
+ "@value": "nrel00001151"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000748",
+ "@id": "urn:nrel_example/nrel00001264",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -12628,133 +12875,125 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000748"
+ "@value": "nrel00001264"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000403",
+ "@id": "urn:nrel_example/nrel00000800",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00001064"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ {
+ "@id": "urn:nrel_example/nrel00000500"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000216"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000403"
+ "@value": "nrel00000800"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000479",
+ "@id": "urn:nrel_example/nrel00000981",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
- }
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000479"
+ "@value": "nrel00000981"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000651",
+ "@id": "urn:nrel_example/nrel00001146",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Energy"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW-HR"
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000651"
+ "@value": "nrel00001146"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000001",
+ "@id": "urn:nrel_example/nrel00000432",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000001"
+ "@value": "nrel00000432"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000903",
+ "@id": "urn:nrel_example/nrel00000356",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000589"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000903"
+ "@value": "nrel00000356"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001331",
+ "@id": "urn:nrel_example/nrel00000635",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001331"
+ "@value": "nrel00000635"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000149",
+ "@id": "urn:nrel_example/nrel00000984",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000211"
- },
- {
- "@id": "urn:nrel_example/nrel00000942"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -12763,161 +13002,154 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000149"
+ "@value": "nrel00000984"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000047",
+ "@id": "urn:nrel_example/nrel00000437",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000047"
+ "@value": "nrel00000437"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000462",
+ "@id": "urn:nrel_example/nrel00000670",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@value": "nrel00000462"
+ "@id": "http://qudt.org/vocab/unit/A"
}
- ]
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000670"
+ }
+ ]
},
{
- "@id": "urn:nrel_example/nrel00000657",
+ "@id": "urn:nrel_example/nrel00000062",
"@type": [
"http://data.ashrae.org/standard223#Valve"
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000779"
+ "@id": "urn:nrel_example/nrel00000514"
},
{
- "@id": "urn:nrel_example/nrel00000912"
+ "@id": "urn:nrel_example/nrel00000913"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000767"
+ "@id": "urn:nrel_example/nrel00000601"
},
{
- "@id": "urn:nrel_example/nrel00001133"
+ "@id": "urn:nrel_example/nrel00000793"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000657"
+ "@value": "nrel00000062"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000486",
+ "@id": "urn:nrel_example/nrel00000318",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001125"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000500"
+ "@value": "nrel00000318"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000436",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00001280"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000486"
+ "@value": "nrel00000436"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000524",
+ "@id": "urn:nrel_example/nrel00000679",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000967"
- }
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000865"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000524"
+ "@value": "nrel00000679"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000566",
+ "@id": "urn:nrel_example/nrel00001235",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00000566"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00001260",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001260"
+ "@value": "nrel00001235"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000618",
+ "@id": "urn:nrel_example/nrel00000535",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000517"
+ "@id": "urn:nrel_example/nrel00000691"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000699"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -12927,112 +13159,102 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000618"
+ "@value": "nrel00000535"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000868",
+ "@id": "urn:nrel_example/nrel00000300",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "urn:nrel_example/nrel00001050"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:nrel_example/nrel00000518"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000868"
+ "@value": "nrel00000300"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000705",
+ "@id": "urn:nrel_example/nrel00000264",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000705"
+ "@value": "nrel00000264"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000820",
+ "@id": "urn:nrel_example/nrel00000681",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000820"
+ "@value": "nrel00000681"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000140",
+ "@id": "urn:nrel_example/nrel00001133",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000140"
+ "@value": "nrel00001133"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000956",
+ "@id": "urn:nrel_example/nrel00001200",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000956"
+ "@value": "nrel00001200"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000638",
+ "@id": "urn:nrel_example/nrel00000305",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -13043,65 +13265,75 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000638"
+ "@value": "nrel00000305"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000037",
+ "@id": "urn:nrel_example/nrel00000450",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/KiloW"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000037"
+ "@value": "nrel00000450"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001309",
+ "@id": "urn:nrel_example/nrel00000486",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "urn:nrel_example/nrel00001125"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:nrel_example/nrel00000500"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00001280"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001309"
+ "@value": "nrel00000486"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001237",
+ "@id": "urn:nrel_example/nrel00000051",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001237"
+ "@value": "nrel00000051"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001271",
+ "@id": "urn:nrel_example/nrel00001041",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
@@ -13112,146 +13344,123 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001271"
+ "@value": "nrel00001041"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000510",
+ "@id": "urn:nrel_example/nrel00000242",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000961"
+ "@id": "http://qudt.org/vocab/quantitykind/Frequency"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000475"
+ "@id": "http://qudt.org/vocab/unit/HZ"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000510"
+ "@value": "nrel00000242"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000464",
+ "@id": "urn:nrel_example/nrel00000863",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
- ],
- "http://data.ashrae.org/standard223#encloses": [
- {
- "@id": "urn:nrel_example/nrel00000862"
- }
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000825"
- },
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000956"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000464"
+ "@value": "nrel00000863"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000453",
+ "@id": "urn:nrel_example/nrel00000137",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Frequency"
+ "@id": "urn:nrel_example/nrel00000810"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/HZ"
+ "@id": "urn:nrel_example/nrel00000623"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000453"
+ "@value": "nrel00000137"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001317",
+ "@id": "urn:nrel_example/nrel00000215",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
- {
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001317"
+ "@value": "nrel00000215"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001318",
+ "@id": "urn:nrel_example/nrel00001025",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000122"
- }
- ],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
- {
- "@id": "urn:nrel_example/nrel00001027"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000335"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001318"
+ "@value": "nrel00001025"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000125",
+ "@id": "urn:nrel_example/nrel00000359",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/A"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000125"
+ "@value": "nrel00000359"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000684",
+ "@id": "urn:nrel_example/nrel00000592",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -13267,663 +13476,554 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000684"
+ "@value": "nrel00000592"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001114",
+ "@id": "urn:nrel_example/nrel00001294",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001086"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000336"
+ "@value": "nrel00001294"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000836",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000471"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001114"
+ "@value": "nrel00000836"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001012",
+ "@id": "urn:nrel_example/nrel00001207",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00001299"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000166"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001012"
+ "@value": "nrel00001207"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000397",
+ "@id": "urn:nrel_example/nrel00000198",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000255"
- },
- {
- "@id": "urn:nrel_example/nrel00000908"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000397"
+ "@value": "nrel00000198"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000500",
+ "@id": "urn:nrel_example/nrel00000601",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
- ],
- "http://data.ashrae.org/standard223#encloses": [
- {
- "@id": "urn:nrel_example/nrel00001125"
- }
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000216"
- },
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00001168"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000500"
+ "@value": "nrel00000601"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001029",
+ "@id": "urn:nrel_example/nrel00000664",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000388"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000673"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001029"
+ "@value": "nrel00000664"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001062",
+ "@id": "urn:nrel_example/nrel00000769",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:nrel_example/nrel00000162"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ {
+ "@id": "urn:nrel_example/nrel00000969"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000054"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001062"
+ "@value": "nrel00000769"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000649",
+ "@id": "urn:nrel_example/nrel00001310",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000364"
- },
- {
- "@id": "urn:nrel_example/nrel00000516"
- },
- {
- "@id": "urn:nrel_example/nrel00000893"
- },
- {
- "@id": "urn:nrel_example/nrel00001139"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000182"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001178"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000649"
+ "@value": "nrel00001310"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001229",
+ "@id": "urn:nrel_example/nrel00000403",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001229"
+ "@value": "nrel00000403"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001113",
+ "@id": "urn:nrel_example/nrel00000141",
"@type": [
- "http://data.ashrae.org/standard223#Junction"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000043"
- },
- {
- "@id": "urn:nrel_example/nrel00000790"
- },
- {
- "@id": "urn:nrel_example/nrel00000802"
- },
- {
- "@id": "urn:nrel_example/nrel00000841"
- },
- {
- "@id": "urn:nrel_example/nrel00001182"
- },
- {
- "@id": "urn:nrel_example/nrel00001203"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001242"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001113"
+ "@value": "nrel00000141"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000905",
+ "@id": "urn:nrel_example/nrel00000470",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000444"
- },
+ "@id": "urn:nrel_example/nrel00001267"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "urn:nrel_example/nrel00000597"
+ "@id": "urn:nrel_example/nrel00001165"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000743"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000905"
+ "@value": "nrel00000470"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001249",
+ "@id": "urn:nrel_example/nrel00001107",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001249"
+ "@value": "nrel00001107"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000160",
+ "@id": "urn:nrel_example/nrel00000184",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000587"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000225"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001286"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000160"
+ "@value": "nrel00000184"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000790",
+ "@id": "urn:nrel_example/nrel00000183",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000790"
+ "@value": "nrel00000183"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001277",
+ "@id": "urn:nrel_example/nrel00000150",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00001080"
- },
- {
- "@id": "urn:nrel_example/nrel00001123"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001277"
+ "@value": "nrel00000150"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001196",
+ "@id": "urn:nrel_example/nrel00001227",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001196"
+ "@value": "nrel00001227"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000036",
+ "@id": "urn:nrel_example/nrel00000472",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "urn:nrel_example/nrel00001241"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:nrel_example/nrel00000256"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000036"
+ "@value": "nrel00000472"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000206",
+ "@id": "urn:nrel_example/nrel00000858",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000206"
+ "@value": "nrel00000858"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000683",
+ "@id": "urn:nrel_example/nrel00000255",
"@type": [
- "http://data.ashrae.org/standard223#HeatExchanger"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000083"
- },
- {
- "@id": "urn:nrel_example/nrel00000344"
- },
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000546"
+ "@id": "urn:nrel_example/nrel00000397"
}
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000183"
- },
- {
- "@id": "urn:nrel_example/nrel00000189"
- },
- {
- "@id": "urn:nrel_example/nrel00000271"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000923"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000067"
- },
- {
- "@id": "urn:nrel_example/nrel00000163"
- },
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00001094"
+ "@value": "nrel00000255"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000223",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Evaporator"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000683"
+ "@value": "nrel00000223"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001014",
+ "@id": "urn:nrel_example/nrel00000258",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:nrel_example/nrel00000459"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001007"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001014"
+ "@value": "nrel00000258"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000322",
+ "@id": "urn:nrel_example/nrel00000868",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00001259"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000500"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001168"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000322"
+ "@value": "nrel00000868"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000853",
+ "@id": "urn:nrel_example/nrel00001009",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/IN_H2O"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000853"
+ "@value": "nrel00001009"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000958",
+ "@id": "urn:nrel_example/nrel00000649",
"@type": [
- "http://data.ashrae.org/standard223#TerminalUnit"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000152"
- },
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000521"
+ "@id": "urn:nrel_example/nrel00000364"
},
{
- "@id": "urn:nrel_example/nrel00000591"
+ "@id": "urn:nrel_example/nrel00000516"
},
{
- "@id": "urn:nrel_example/nrel00000628"
+ "@id": "urn:nrel_example/nrel00000893"
},
{
- "@id": "urn:nrel_example/nrel00001155"
+ "@id": "urn:nrel_example/nrel00001139"
}
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000208"
- },
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:nrel_example/nrel00000354"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000139"
- },
- {
- "@id": "urn:nrel_example/nrel00000823"
+ "@id": "urn:nrel_example/nrel00000182"
},
{
- "@id": "urn:nrel_example/nrel00000985"
+ "@id": "urn:nrel_example/nrel00001178"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000958"
+ "@value": "nrel00000649"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000952",
+ "@id": "urn:nrel_example/nrel00000743",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@value": "nrel00000952"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000161",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000161"
+ "@value": "nrel00000743"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000445",
+ "@id": "urn:nrel_example/nrel00001155",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "urn:nrel_example/nrel00000354"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:nrel_example/nrel00000985"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000445"
+ "@value": "nrel00001155"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000585",
+ "@id": "urn:nrel_example/nrel00000471",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000585"
+ "@value": "nrel00000471"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000917",
+ "@id": "urn:nrel_example/nrel00000171",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000948"
- }
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000124"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000098"
+ },
{
- "@value": "nrel00000917"
+ "@id": "urn:nrel_example/nrel00001207"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00001064",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -13932,123 +14032,156 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001064"
+ "@value": "nrel00000171"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001202",
+ "@id": "urn:nrel_example/nrel00000847",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001202"
+ "@value": "nrel00000847"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000755",
+ "@id": "urn:nrel_example/nrel00000593",
"@type": [
"http://data.ashrae.org/standard223#Valve"
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000380"
+ "@id": "urn:nrel_example/nrel00000087"
},
{
- "@id": "urn:nrel_example/nrel00000491"
+ "@id": "urn:nrel_example/nrel00000434"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000473"
+ "@id": "urn:nrel_example/nrel00000301"
},
{
- "@id": "urn:nrel_example/nrel00000883"
+ "@id": "urn:nrel_example/nrel00001215"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000755"
+ "@value": "nrel00000593"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000909",
+ "@id": "urn:nrel_example/nrel00000933",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000658"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000282"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000091"
+ "@value": "nrel00000933"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000317",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000909"
+ "@value": "nrel00000317"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000307",
+ "@id": "urn:nrel_example/nrel00001258",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000517"
+ "@id": "urn:nrel_example/nrel00000120"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000415"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000349"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000644"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000307"
+ "@value": "nrel00001258"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000974",
+ "@id": "urn:nrel_example/nrel00000536",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Frequency"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://qudt.org/vocab/unit/HZ"
+ "@value": "nrel00000536"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000131",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000974"
+ "@value": "nrel00000131"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000020",
+ "@id": "urn:nrel_example/nrel00000584",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -14064,566 +14197,590 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000020"
+ "@value": "nrel00000584"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000035",
+ "@id": "urn:nrel_example/nrel00000909",
"@type": [
- "http://data.ashrae.org/standard223#CoolingCoil"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000522"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000824"
+ "@id": "urn:nrel_example/nrel00000658"
}
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000317"
- },
- {
- "@id": "urn:nrel_example/nrel00000685"
- },
- {
- "@id": "urn:nrel_example/nrel00000808"
- },
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "urn:nrel_example/nrel00000976"
+ "@id": "urn:nrel_example/nrel00000282"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000028"
- },
- {
- "@id": "urn:nrel_example/nrel00000085"
- },
- {
- "@id": "urn:nrel_example/nrel00000243"
- },
- {
- "@id": "urn:nrel_example/nrel00000253"
- },
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00000994"
+ "@id": "urn:nrel_example/nrel00000091"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000035"
+ "@value": "nrel00000909"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000940",
+ "@id": "urn:nrel_example/nrel00000456",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000050"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000940"
+ "@value": "nrel00000456"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000574",
+ "@id": "urn:nrel_example/nrel00000216",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001211"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000574"
+ "@value": "nrel00000216"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001115",
+ "@id": "urn:nrel_example/nrel00000683",
"@type": [
- "http://data.ashrae.org/standard223#Pump"
+ "http://data.ashrae.org/standard223#HeatExchanger"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:nrel_example/nrel00000014"
+ "@id": "urn:nrel_example/nrel00000083"
},
{
- "@id": "urn:nrel_example/nrel00000237"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000102"
+ "@id": "urn:nrel_example/nrel00000344"
},
{
- "@id": "urn:nrel_example/nrel00000108"
- },
+ "@id": "urn:nrel_example/nrel00000546"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000327"
+ "@id": "urn:nrel_example/nrel00000183"
},
{
- "@id": "urn:nrel_example/nrel00000338"
+ "@id": "urn:nrel_example/nrel00000189"
},
{
- "@id": "urn:nrel_example/nrel00000453"
+ "@id": "urn:nrel_example/nrel00000271"
},
{
- "@id": "urn:nrel_example/nrel00000633"
- },
+ "@id": "urn:nrel_example/nrel00000923"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000732"
+ "@id": "urn:nrel_example/nrel00000067"
},
{
- "@id": "urn:nrel_example/nrel00001118"
+ "@id": "urn:nrel_example/nrel00000163"
},
{
- "@id": "urn:nrel_example/nrel00001148"
- },
+ "@id": "urn:nrel_example/nrel00001094"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "urn:nrel_example/nrel00001206"
+ "@id": "http://data.ashrae.org/standard223#Role-Evaporator"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001115"
+ "@value": "nrel00000683"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000060",
+ "@id": "urn:nrel_example/nrel00000912",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@value": "nrel00000912"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000949",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000060"
+ "@value": "nrel00000949"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000471",
+ "@id": "urn:nrel_example/nrel00000740",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000471"
+ "@value": "nrel00000740"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000707",
+ "@id": "urn:nrel_example/nrel00000704",
"@type": [
- "http://data.ashrae.org/standard223#Pump"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000735"
- },
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00001172"
+ "@value": "nrel00000704"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000126",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000086"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000089"
+ "@id": "http://qudt.org/vocab/unit/KiloW"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000126"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000780",
+ "@type": [
+ "http://data.ashrae.org/standard223#CoolingCoil"
+ ],
+ "http://data.ashrae.org/standard223#contains": [
+ {
+ "@id": "urn:nrel_example/nrel00000179"
},
{
- "@id": "urn:nrel_example/nrel00000129"
+ "@id": "urn:nrel_example/nrel00001015"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "urn:nrel_example/nrel00000525"
},
{
- "@id": "urn:nrel_example/nrel00000326"
+ "@id": "urn:nrel_example/nrel00000826"
},
{
- "@id": "urn:nrel_example/nrel00000513"
+ "@id": "urn:nrel_example/nrel00001043"
},
{
- "@id": "urn:nrel_example/nrel00000659"
+ "@id": "urn:nrel_example/nrel00001063"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000191"
},
{
- "@id": "urn:nrel_example/nrel00000728"
+ "@id": "urn:nrel_example/nrel00000394"
},
{
- "@id": "urn:nrel_example/nrel00001098"
+ "@id": "urn:nrel_example/nrel00000556"
},
{
- "@id": "urn:nrel_example/nrel00001110"
+ "@id": "urn:nrel_example/nrel00000592"
},
{
- "@id": "urn:nrel_example/nrel00001237"
+ "@id": "urn:nrel_example/nrel00001001"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000707"
+ "@value": "nrel00000780"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001298",
+ "@id": "urn:nrel_example/nrel00000444",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001298"
+ "@value": "nrel00000444"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000096",
+ "@id": "urn:nrel_example/nrel00000808",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000096"
+ "@value": "nrel00000808"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000283",
+ "@id": "urn:nrel_example/nrel00001312",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:nrel_example/nrel00000818"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@value": "nrel00000283"
+ "@id": "urn:nrel_example/nrel00000336"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00001299",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:nrel_example/nrel00001130"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001299"
+ "@value": "nrel00001312"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000150",
+ "@id": "urn:nrel_example/nrel00001149",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:nrel_example/nrel00000742"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000150"
+ "@value": "nrel00001149"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000549",
+ "@id": "urn:nrel_example/nrel00000544",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000050"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000760"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000549"
+ "@value": "nrel00000544"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000348",
+ "@id": "urn:nrel_example/nrel00000144",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ "@id": "http://qudt.org/vocab/quantitykind/Energy"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "http://qudt.org/vocab/unit/KiloW-HR"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000348"
+ "@value": "nrel00000144"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001103",
+ "@id": "urn:nrel_example/nrel00001304",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@value": "nrel00001304"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000210",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ {
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-FlowStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001103"
+ "@value": "nrel00000210"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000545",
+ "@id": "urn:nrel_example/nrel00000573",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:nrel_example/nrel00000941"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:nrel_example/nrel00000121"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000404"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000545"
+ "@value": "nrel00000573"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001278",
+ "@id": "urn:nrel_example/nrel00001114",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00001260"
- },
+ "@id": "urn:nrel_example/nrel00001086"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "urn:nrel_example/nrel00001311"
+ "@id": "urn:nrel_example/nrel00000336"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000471"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001278"
+ "@value": "nrel00001114"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000938",
+ "@id": "urn:nrel_example/nrel00000209",
"@type": [
- "http://data.ashrae.org/standard223#TerminalUnit"
+ "http://data.ashrae.org/standard223#FanCoilUnit"
],
"http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:nrel_example/nrel00000073"
- },
- {
- "@id": "urn:nrel_example/nrel00000324"
+ "@id": "urn:nrel_example/nrel00000099"
},
{
- "@id": "urn:nrel_example/nrel00000510"
+ "@id": "urn:nrel_example/nrel00000135"
},
{
- "@id": "urn:nrel_example/nrel00001223"
- },
- {
- "@id": "urn:nrel_example/nrel00001232"
+ "@id": "urn:nrel_example/nrel00000904"
}
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000742"
+ "@id": "urn:nrel_example/nrel00000131"
},
{
- "@id": "urn:nrel_example/nrel00000961"
+ "@id": "urn:nrel_example/nrel00000355"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000064"
+ "@id": "urn:nrel_example/nrel00000392"
},
{
- "@id": "urn:nrel_example/nrel00000332"
+ "@id": "urn:nrel_example/nrel00000752"
},
{
- "@id": "urn:nrel_example/nrel00000475"
+ "@id": "urn:nrel_example/nrel00000805"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001160"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001233"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@value": "nrel00000938"
+ "@id": "http://data.ashrae.org/standard223#Role-Cooling"
+ },
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
- ]
- },
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Default",
- "@type": [
- "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus",
- "http://data.ashrae.org/standard223#EnumerationKind-Override"
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@language": "en",
- "@value": "AlarmStatus-Alarm"
- },
- {
- "@language": "en",
- "@value": "Override-Default"
+ "@value": "nrel00000209"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000602",
+ "@id": "urn:nrel_example/nrel00000136",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000032"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000358"
+ "@id": "http://qudt.org/vocab/unit/KiloW"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000602"
+ "@value": "nrel00000136"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000425",
+ "@id": "urn:nrel_example/nrel00001070",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000425"
+ "@value": "nrel00001070"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001204",
+ "@id": "urn:nrel_example/nrel00000603",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001204"
+ "@value": "nrel00000603"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000639",
+ "@id": "urn:nrel_example/nrel00001088",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
@@ -14634,77 +14791,93 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000639"
+ "@value": "nrel00001088"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000152",
+ "@id": "urn:nrel_example/nrel00000529",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000354"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000823"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000152"
+ "@value": "nrel00000529"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001312",
+ "@id": "urn:nrel_example/nrel00001262",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00001262"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000334",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000818"
+ "@id": "urn:nrel_example/nrel00000587"
}
],
"http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "urn:nrel_example/nrel00000336"
+ "@id": "urn:nrel_example/nrel00000160"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00001130"
+ "@id": "urn:nrel_example/nrel00000433"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001312"
+ "@value": "nrel00000334"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000737",
+ "@id": "urn:nrel_example/nrel00000451",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000737"
+ "@value": "nrel00000451"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000846",
+ "@id": "urn:nrel_example/nrel00000162",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -14713,60 +14886,44 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000846"
+ "@value": "nrel00000162"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000188",
+ "@id": "urn:nrel_example/nrel00000347",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000249"
- },
- {
- "@id": "urn:nrel_example/nrel00000596"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000694"
- },
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000700"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000188"
+ "@value": "nrel00000347"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001071",
+ "@id": "urn:nrel_example/nrel00000901",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000748"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001236"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001071"
+ "@value": "nrel00000901"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000265",
+ "@id": "urn:nrel_example/nrel00000045",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -14777,79 +14934,35 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000265"
+ "@value": "nrel00000045"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001305",
+ "@id": "urn:nrel_example/nrel00000118",
"@type": [
- "http://data.ashrae.org/standard223#Junction"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000399"
- },
- {
- "@id": "urn:nrel_example/nrel00000438"
- },
- {
- "@id": "urn:nrel_example/nrel00000603"
- },
- {
- "@id": "urn:nrel_example/nrel00000640"
- },
- {
- "@id": "urn:nrel_example/nrel00000775"
- },
- {
- "@id": "urn:nrel_example/nrel00000806"
- },
- {
- "@id": "urn:nrel_example/nrel00000924"
- },
- {
- "@id": "urn:nrel_example/nrel00000942"
- },
- {
- "@id": "urn:nrel_example/nrel00000947"
- },
- {
- "@id": "urn:nrel_example/nrel00001007"
- },
- {
- "@id": "urn:nrel_example/nrel00001068"
- },
- {
- "@id": "urn:nrel_example/nrel00001080"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001193"
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/IN_H2O"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001305"
+ "@value": "nrel00000118"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000589",
+ "@id": "urn:nrel_example/nrel00000438",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000240"
- },
- {
- "@id": "urn:nrel_example/nrel00000903"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -14858,112 +14971,131 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000589"
+ "@value": "nrel00000438"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000443",
+ "@id": "urn:nrel_example/nrel00000575",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/IN_H2O"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000443"
+ "@value": "nrel00000575"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001118",
+ "@id": "urn:nrel_example/nrel00000268",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Energy"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW-HR"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001118"
+ "@value": "nrel00000268"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000244",
+ "@id": "urn:nrel_example/nrel00000429",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Filter"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-FlowStatus"
+ "@id": "urn:nrel_example/nrel00000158"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000940"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000250"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000244"
+ "@value": "nrel00000429"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000831",
+ "@id": "urn:nrel_example/nrel00000651",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Energy"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/KiloW-HR"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000831"
+ "@value": "nrel00000651"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000935",
+ "@id": "urn:nrel_example/nrel00000069",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000069"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000599",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000935"
+ "@value": "nrel00000599"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000459",
+ "@id": "urn:nrel_example/nrel00000950",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -14974,14 +15106,14 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000459"
+ "@value": "nrel00000950"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001129",
+ "@id": "urn:nrel_example/nrel00000482",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -14990,274 +15122,225 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001129"
+ "@value": "nrel00000482"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000335",
+ "@id": "urn:nrel_example/nrel00000054",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000335"
+ "@value": "nrel00000054"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000135",
+ "@id": "urn:nrel_example/nrel00000598",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil"
- ],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000340"
- },
- {
- "@id": "urn:nrel_example/nrel00000734"
- },
- {
- "@id": "urn:nrel_example/nrel00000906"
- }
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000051"
- },
- {
- "@id": "urn:nrel_example/nrel00000075"
- },
- {
- "@id": "urn:nrel_example/nrel00000914"
- },
- {
- "@id": "urn:nrel_example/nrel00001250"
- }
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000202"
- },
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000740"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000135"
+ "@value": "nrel00000598"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000306",
+ "@id": "urn:nrel_example/nrel00000871",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000306"
+ "@value": "nrel00000871"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000132",
+ "@id": "urn:nrel_example/nrel00001282",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000132"
+ "@value": "nrel00001282"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000468",
+ "@id": "urn:nrel_example/nrel00000643",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000468"
+ "@value": "nrel00000643"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000381",
+ "@id": "urn:nrel_example/nrel00000254",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil"
- ],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000049"
- },
- {
- "@id": "urn:nrel_example/nrel00000582"
- },
- {
- "@id": "urn:nrel_example/nrel00000657"
- }
+ "http://data.ashrae.org/standard223#Damper"
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000165"
- },
- {
- "@id": "urn:nrel_example/nrel00001040"
- },
- {
- "@id": "urn:nrel_example/nrel00001074"
+ "@id": "urn:nrel_example/nrel00000424"
},
{
- "@id": "urn:nrel_example/nrel00001279"
+ "@id": "urn:nrel_example/nrel00001274"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000175"
+ "@id": "urn:nrel_example/nrel00000288"
},
{
- "@id": "urn:nrel_example/nrel00000571"
+ "@id": "urn:nrel_example/nrel00000617"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000381"
+ "@value": "nrel00000254"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001178",
+ "@id": "urn:nrel_example/nrel00000214",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ "@id": "urn:nrel_example/nrel00000408"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000526"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "urn:nrel_example/nrel00000395"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001170"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001178"
+ "@value": "nrel00000214"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000303",
+ "@id": "urn:nrel_example/nrel00000973",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000303"
+ "@value": "nrel00000973"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000919",
+ "@id": "urn:nrel_example/nrel00001004",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000026"
+ "@id": "urn:nrel_example/nrel00000221"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ {
+ "@id": "urn:nrel_example/nrel00000336"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00000094"
+ "@id": "urn:nrel_example/nrel00000680"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000919"
+ "@value": "nrel00001004"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001212",
+ "@id": "urn:nrel_example/nrel00001242",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001212"
+ "@value": "nrel00001242"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000914",
+ "@id": "urn:nrel_example/nrel00000996",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000914"
+ "@value": "nrel00000996"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000565",
+ "@id": "urn:nrel_example/nrel00001307",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -15273,59 +15356,75 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000565"
+ "@value": "nrel00001307"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000435",
+ "@id": "urn:nrel_example/nrel00000837",
"@type": [
- "http://data.ashrae.org/standard223#TerminalUnit"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000110"
- },
- {
- "@id": "urn:nrel_example/nrel00000142"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000460"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000849"
- },
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000917"
+ "@value": "nrel00000837"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000330",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000462"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000948"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000048"
- },
+ "@value": "nrel00000330"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000930",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000124"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000641"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000435"
+ "@value": "nrel00000930"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000973",
+ "@id": "urn:nrel_example/nrel00000655",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -15334,14 +15433,35 @@
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:nrel_example/nrel00000688"
+ }
+ ],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000973"
+ "@value": "nrel00000655"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000143",
+ "@id": "urn:nrel_example/nrel00001058",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ {
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00001058"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000326",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
@@ -15352,146 +15472,157 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000143"
+ "@value": "nrel00000326"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000693",
+ "@id": "urn:nrel_example/nrel00000477",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001194"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000373"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000693"
+ "@value": "nrel00000477"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000094",
+ "@id": "urn:nrel_example/nrel00001103",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000094"
+ "@value": "nrel00001103"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000097",
+ "@id": "urn:nrel_example/nrel00001112",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000097"
+ "@value": "nrel00001112"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000023",
+ "@id": "urn:nrel_example/nrel00001249",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000023"
+ "@value": "nrel00001249"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000260",
+ "@id": "urn:nrel_example/nrel00000953",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@value": "nrel00000953"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001117",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000260"
+ "@value": "nrel00001117"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000920",
+ "@id": "urn:nrel_example/nrel00000804",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000638"
+ "@id": "urn:nrel_example/nrel00000612"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00000412"
+ "@id": "urn:nrel_example/nrel00000895"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000920"
+ "@value": "nrel00000804"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000977",
+ "@id": "urn:nrel_example/nrel00001171",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000977"
+ "@value": "nrel00001171"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001041",
+ "@id": "urn:nrel_example/nrel00000468",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
@@ -15500,65 +15631,86 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001041"
+ "@value": "nrel00000468"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000653",
+ "@id": "urn:nrel_example/nrel00000238",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/Frequency"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/HZ"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000653"
+ "@value": "nrel00000238"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001230",
+ "@id": "urn:nrel_example/nrel00000509",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000509"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000637",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001230"
+ "@value": "nrel00000637"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000481",
+ "@id": "urn:nrel_example/nrel00000779",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000481"
+ "@value": "nrel00000779"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001065",
+ "@id": "urn:nrel_example/nrel00000115",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
@@ -15569,37 +15721,59 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001065"
+ "@value": "nrel00000115"
}
]
},
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override",
+ "@id": "urn:nrel_example/nrel00000201",
"@type": [
- "http://data.ashrae.org/standard223#Class",
- "http://data.ashrae.org/standard223#EnumerationKind-Override",
- "http://www.w3.org/ns/shacl#NodeShape"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@value": "EnumerationKind Override"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
- "http://www.w3.org/2000/01/rdf-schema#subClassOf": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind"
+ "@value": "nrel00000201"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001291",
+ "@id": "urn:nrel_example/nrel00000160",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "urn:nrel_example/nrel00000421"
- },
+ "@id": "urn:nrel_example/nrel00000587"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000225"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001286"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000160"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001291",
+ "@type": [
+ "http://data.ashrae.org/standard223#HeatingCoil"
+ ],
+ "http://data.ashrae.org/standard223#contains": [
+ {
+ "@id": "urn:nrel_example/nrel00000421"
+ },
{
"@id": "urn:nrel_example/nrel00000919"
},
@@ -15636,16 +15810,16 @@
]
},
{
- "@id": "urn:nrel_example/nrel00000088",
+ "@id": "urn:nrel_example/nrel00000149",
"@type": [
"http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000986"
+ "@id": "urn:nrel_example/nrel00000211"
},
{
- "@id": "urn:nrel_example/nrel00001194"
+ "@id": "urn:nrel_example/nrel00000942"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -15655,202 +15829,129 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000088"
+ "@value": "nrel00000149"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000092",
+ "@id": "urn:nrel_example/nrel00000770",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000017"
- }
+ "http://data.ashrae.org/standard223#Fan"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000275"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000882"
+ },
{
- "@value": "nrel00000092"
+ "@id": "urn:nrel_example/nrel00001192"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000233",
- "@type": [
- "http://data.ashrae.org/standard223#FanCoilUnit"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000226"
+ "@id": "urn:nrel_example/nrel00000143"
},
{
- "@id": "urn:nrel_example/nrel00000568"
+ "@id": "urn:nrel_example/nrel00000244"
},
{
- "@id": "urn:nrel_example/nrel00001291"
- }
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000512"
+ "@id": "urn:nrel_example/nrel00000276"
},
{
- "@id": "urn:nrel_example/nrel00001208"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "@id": "urn:nrel_example/nrel00000311"
+ },
{
- "@id": "urn:nrel_example/nrel00000115"
+ "@id": "urn:nrel_example/nrel00000624"
},
{
- "@id": "urn:nrel_example/nrel00000348"
+ "@id": "urn:nrel_example/nrel00000753"
},
{
- "@id": "urn:nrel_example/nrel00000451"
+ "@id": "urn:nrel_example/nrel00000943"
},
{
- "@id": "urn:nrel_example/nrel00001002"
+ "@id": "urn:nrel_example/nrel00001035"
},
{
- "@id": "urn:nrel_example/nrel00001212"
- }
- ],
- "http://data.ashrae.org/standard223#hasRole": [
+ "@id": "urn:nrel_example/nrel00001055"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Role-Cooling"
+ "@id": "urn:nrel_example/nrel00001309"
},
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "urn:nrel_example/nrel00001322"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000233"
+ "@value": "nrel00000770"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000237",
+ "@id": "urn:nrel_example/nrel00000284",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000237"
+ "@value": "nrel00000284"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000580",
+ "@id": "urn:nrel_example/nrel00000433",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil"
- ],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000337"
- },
- {
- "@id": "urn:nrel_example/nrel00000741"
- },
- {
- "@id": "urn:nrel_example/nrel00001190"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000229"
- },
- {
- "@id": "urn:nrel_example/nrel00000389"
- },
- {
- "@id": "urn:nrel_example/nrel00000463"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000756"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000968"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001307"
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000580"
+ "@value": "nrel00000433"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000746",
+ "@id": "urn:nrel_example/nrel00000721",
"@type": [
- "http://data.ashrae.org/standard223#EAU",
- "http://data.ashrae.org/standard223#Equipment"
- ],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000343"
- },
- {
- "@id": "urn:nrel_example/nrel00000429"
- },
- {
- "@id": "urn:nrel_example/nrel00000675"
- },
- {
- "@id": "urn:nrel_example/nrel00000771"
- },
- {
- "@id": "urn:nrel_example/nrel00001003"
- },
- {
- "@id": "urn:nrel_example/nrel00001089"
- },
- {
- "@id": "urn:nrel_example/nrel00001100"
- },
- {
- "@id": "urn:nrel_example/nrel00001119"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000050"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000134"
+ "@id": "http://qudt.org/vocab/quantitykind/Energy"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000669"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000853"
+ "@id": "http://qudt.org/vocab/unit/KiloW-HR"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000746"
+ "@value": "nrel00000721"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000832",
+ "@id": "urn:nrel_example/nrel00000234",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -15866,38 +15967,28 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000832"
+ "@value": "nrel00000234"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000842",
+ "@id": "urn:nrel_example/nrel00000924",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000939"
- }
- ],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
- {
- "@id": "urn:nrel_example/nrel00000708"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001090"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000842"
+ "@value": "nrel00000924"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000075",
+ "@id": "urn:nrel_example/nrel00001050",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -15908,131 +15999,97 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000075"
+ "@value": "nrel00001050"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000386",
+ "@id": "urn:nrel_example/nrel00000954",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000386"
+ "@value": "nrel00000954"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000633",
+ "@id": "urn:nrel_example/nrel00001091",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000633"
+ "@value": "nrel00001091"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000284",
+ "@id": "urn:nrel_example/nrel00000414",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:nrel_example/nrel00000207"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00000284"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00001288",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
- {
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:nrel_example/nrel00001163"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001288"
+ "@value": "nrel00000414"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000845",
+ "@id": "urn:nrel_example/nrel00001039",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-FlowStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000845"
+ "@value": "nrel00001039"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000114",
+ "@id": "urn:nrel_example/nrel00000716",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
- ],
- "http://data.ashrae.org/standard223#encloses": [
- {
- "@id": "urn:nrel_example/nrel00000600"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000477"
- },
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000594"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000114"
+ "@value": "nrel00000716"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001234",
+ "@id": "urn:nrel_example/nrel00000722",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -16043,54 +16100,28 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001234"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000193",
- "@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000939"
- }
- ],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
- {
- "@id": "urn:nrel_example/nrel00000708"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
- {
- "@id": "urn:nrel_example/nrel00000308"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00000193"
+ "@value": "nrel00000722"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000124",
+ "@id": "urn:nrel_example/nrel00000650",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/IN_H2O"
+ "@id": "http://qudt.org/vocab/unit/A"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000124"
+ "@value": "nrel00000650"
}
]
},
@@ -16122,220 +16153,207 @@
]
},
{
- "@id": "urn:nrel_example/nrel00000739",
+ "@id": "urn:nrel_example/nrel00000937",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "http://qudt.org/vocab/unit/A"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000739"
+ "@value": "nrel00000937"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001057",
+ "@id": "urn:nrel_example/nrel00000453",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/Frequency"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/HZ"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001057"
+ "@value": "nrel00000453"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000460",
+ "@id": "urn:nrel_example/nrel00000233",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil"
+ "http://data.ashrae.org/standard223#FanCoilUnit"
],
"http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:nrel_example/nrel00000300"
+ "@id": "urn:nrel_example/nrel00000226"
},
{
- "@id": "urn:nrel_example/nrel00000817"
+ "@id": "urn:nrel_example/nrel00000568"
},
{
- "@id": "urn:nrel_example/nrel00001162"
+ "@id": "urn:nrel_example/nrel00001291"
}
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000065"
+ "@id": "urn:nrel_example/nrel00000512"
},
{
- "@id": "urn:nrel_example/nrel00001050"
+ "@id": "urn:nrel_example/nrel00001208"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000115"
},
{
- "@id": "urn:nrel_example/nrel00001072"
+ "@id": "urn:nrel_example/nrel00000348"
},
{
- "@id": "urn:nrel_example/nrel00001107"
+ "@id": "urn:nrel_example/nrel00000451"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001002"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001212"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "urn:nrel_example/nrel00000518"
+ "@id": "http://data.ashrae.org/standard223#Role-Cooling"
},
{
- "@id": "urn:nrel_example/nrel00000684"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000460"
+ "@value": "nrel00000233"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000673",
+ "@id": "urn:nrel_example/nrel00000124",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/IN_H2O"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000673"
+ "@value": "nrel00000124"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001283",
+ "@id": "urn:nrel_example/nrel00000853",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/IN_H2O"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001283"
+ "@value": "nrel00000853"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000483",
+ "@id": "urn:nrel_example/nrel00001134",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000862"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000464"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001134"
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000483"
+ "@value": "nrel00001134"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000871",
+ "@id": "urn:nrel_example/nrel00000678",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
- }
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@value": "nrel00000871"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000929",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "@id": "urn:nrel_example/nrel00000931"
+ },
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "urn:nrel_example/nrel00001256"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000929"
+ "@value": "nrel00000678"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000254",
+ "@id": "urn:nrel_example/nrel00000019",
"@type": [
- "http://data.ashrae.org/standard223#Damper"
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000424"
- },
- {
- "@id": "urn:nrel_example/nrel00001274"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000288"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000617"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000254"
+ "@value": "nrel00000019"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000067",
+ "@id": "urn:nrel_example/nrel00001236",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -16351,459 +16369,471 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000067"
+ "@value": "nrel00001236"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001267",
+ "@id": "urn:nrel_example/nrel00001186",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000186"
+ "@id": "urn:nrel_example/nrel00000074"
},
{
- "@id": "urn:nrel_example/nrel00000236"
- },
- {
- "@id": "urn:nrel_example/nrel00000245"
- },
- {
- "@id": "urn:nrel_example/nrel00000339"
- },
- {
- "@id": "urn:nrel_example/nrel00000444"
- },
- {
- "@id": "urn:nrel_example/nrel00000627"
- }
- ],
- "http://data.ashrae.org/standard223#hasDomain": [
- {
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "urn:nrel_example/nrel00001208"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000184"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000743"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001267"
+ "@value": "nrel00001186"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000680",
+ "@id": "urn:nrel_example/nrel00001096",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Junction"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:nrel_example/nrel00000265"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000876"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001135"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000680"
+ "@value": "nrel00001096"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000741",
+ "@id": "urn:nrel_example/nrel00001063",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000463"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001307"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000741"
+ "@value": "nrel00001063"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001181",
+ "@id": "urn:nrel_example/nrel00000844",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000737"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000915"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001181"
+ "@value": "nrel00000844"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000987",
+ "@id": "urn:nrel_example/nrel00001309",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000987"
+ "@value": "nrel00001309"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001080",
+ "@id": "urn:nrel_example/nrel00000344",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Pump"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000944"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001210"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000145"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000170"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000174"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000384"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000456"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000468"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000937"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001081"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001120"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001246"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001080"
+ "@value": "nrel00000344"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000389",
+ "@id": "urn:nrel_example/nrel00001279",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000389"
+ "@value": "nrel00001279"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000113",
+ "@id": "urn:nrel_example/nrel00000180",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/Frequency"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/HZ"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000113"
+ "@value": "nrel00000180"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000234",
+ "@id": "urn:nrel_example/nrel00000089",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Frequency"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/HZ"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000234"
+ "@value": "nrel00000089"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000331",
+ "@id": "urn:nrel_example/nrel00000558",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000331"
+ "@value": "nrel00000558"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001262",
+ "@id": "urn:nrel_example/nrel00001065",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001262"
+ "@value": "nrel00001065"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000802",
+ "@id": "urn:nrel_example/nrel00000974",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Frequency"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/HZ"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000802"
+ "@value": "nrel00000974"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001184",
+ "@id": "urn:nrel_example/nrel00000241",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:nrel_example/nrel00000631"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:nrel_example/nrel00000274"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001283"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001184"
+ "@value": "nrel00000241"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000499",
+ "@id": "urn:nrel_example/nrel00000168",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ "@id": "urn:nrel_example/nrel00001265"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "urn:nrel_example/nrel00000042"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000499"
+ "@value": "nrel00000168"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001164",
+ "@id": "urn:nrel_example/nrel00000834",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001164"
+ "@value": "nrel00000834"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000606",
+ "@id": "urn:nrel_example/nrel00000595",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000606"
+ "@value": "nrel00000595"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000614",
+ "@id": "urn:nrel_example/nrel00000824",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ "@id": "urn:nrel_example/nrel00000386"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000532"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW"
+ "@id": "urn:nrel_example/nrel00000410"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001248"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000614"
+ "@value": "nrel00000824"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001255",
+ "@id": "urn:nrel_example/nrel00000086",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00001255"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000004",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/KiloW"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000004"
+ "@value": "nrel00000086"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000372",
+ "@id": "urn:nrel_example/nrel00001165",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "urn:nrel_example/nrel00000893"
+ "@id": "urn:nrel_example/nrel00001267"
}
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000553"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
+ "@id": "urn:nrel_example/nrel00000567"
+ },
{
- "@id": "urn:nrel_example/nrel00000930"
+ "@id": "urn:nrel_example/nrel00000637"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000372"
+ "@value": "nrel00001165"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000475",
+ "@id": "urn:nrel_example/nrel00000857",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000475"
+ "@value": "nrel00000857"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000146",
+ "@id": "urn:nrel_example/nrel00001122",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000146"
+ "@value": "nrel00001122"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000424",
+ "@id": "urn:nrel_example/nrel00000892",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
@@ -16817,41 +16847,59 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000424"
+ "@value": "nrel00000892"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000205",
+ "@id": "urn:nrel_example/nrel00000527",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000527"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000446",
+ "@type": [
+ "http://data.ashrae.org/standard223#Filter"
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000025"
+ "@id": "urn:nrel_example/nrel00000255"
},
{
- "@id": "urn:nrel_example/nrel00000076"
+ "@id": "urn:nrel_example/nrel00000892"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000194"
- },
- {
- "@id": "urn:nrel_example/nrel00000299"
+ "@id": "urn:nrel_example/nrel00000564"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000205"
+ "@value": "nrel00000446"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001207",
+ "@id": "urn:nrel_example/nrel00000207",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -16860,256 +16908,241 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001207"
+ "@value": "nrel00000207"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001287",
+ "@id": "urn:nrel_example/nrel00001054",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ {
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00001054"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000832",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Frequency"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/HZ"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001287"
+ "@value": "nrel00000832"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001174",
+ "@id": "urn:nrel_example/nrel00000830",
"@type": [
"http://data.ashrae.org/standard223#Fan"
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000588"
+ "@id": "urn:nrel_example/nrel00000252"
},
{
- "@id": "urn:nrel_example/nrel00001294"
+ "@id": "urn:nrel_example/nrel00001159"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000020"
+ "@id": "urn:nrel_example/nrel00000238"
},
{
- "@id": "urn:nrel_example/nrel00000029"
+ "@id": "urn:nrel_example/nrel00000359"
},
{
- "@id": "urn:nrel_example/nrel00000257"
+ "@id": "urn:nrel_example/nrel00000427"
},
{
- "@id": "urn:nrel_example/nrel00000295"
+ "@id": "urn:nrel_example/nrel00000645"
},
{
- "@id": "urn:nrel_example/nrel00000569"
+ "@id": "urn:nrel_example/nrel00000791"
},
{
- "@id": "urn:nrel_example/nrel00000650"
+ "@id": "urn:nrel_example/nrel00000861"
},
{
- "@id": "urn:nrel_example/nrel00000796"
+ "@id": "urn:nrel_example/nrel00000880"
},
{
- "@id": "urn:nrel_example/nrel00000857"
+ "@id": "urn:nrel_example/nrel00000977"
},
{
- "@id": "urn:nrel_example/nrel00000890"
+ "@id": "urn:nrel_example/nrel00001019"
},
{
- "@id": "urn:nrel_example/nrel00001076"
+ "@id": "urn:nrel_example/nrel00001048"
},
{
- "@id": "urn:nrel_example/nrel00001154"
+ "@id": "urn:nrel_example/nrel00001217"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001174"
+ "@value": "nrel00000830"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000689",
+ "@id": "urn:nrel_example/nrel00000021",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00000339"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@value": "nrel00000689"
+ "@id": "urn:nrel_example/nrel00001165"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00001111",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000637"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001111"
+ "@value": "nrel00000021"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001217",
+ "@id": "urn:nrel_example/nrel00000016",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-FlowStatus"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001217"
+ "@value": "nrel00000016"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001155",
+ "@id": "urn:nrel_example/nrel00000553",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "urn:nrel_example/nrel00000354"
+ "@id": "urn:nrel_example/nrel00000649"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000985"
+ "@id": "urn:nrel_example/nrel00000555"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000930"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001155"
+ "@value": "nrel00000553"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000362",
+ "@id": "urn:nrel_example/nrel00000239",
"@type": [
- "http://data.ashrae.org/standard223#FanCoilUnit"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000830"
- },
- {
- "@id": "urn:nrel_example/nrel00000839"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001176"
+ "@id": "http://qudt.org/vocab/quantitykind/Frequency"
}
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000714"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001020"
+ "@id": "http://qudt.org/vocab/unit/HZ"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000527"
- },
- {
- "@id": "urn:nrel_example/nrel00000643"
- },
- {
- "@id": "urn:nrel_example/nrel00000812"
- },
- {
- "@id": "urn:nrel_example/nrel00001065"
- },
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00001082"
+ "@value": "nrel00000239"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000236",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasRole": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Cooling"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000362"
+ "@value": "nrel00000236"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000402",
+ "@id": "urn:nrel_example/nrel00000018",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Energy"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW-HR"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000402"
+ "@value": "nrel00000018"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001072",
+ "@id": "urn:nrel_example/nrel00000785",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001072"
+ "@value": "nrel00000785"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000351",
+ "@id": "urn:nrel_example/nrel00000742",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000172"
- }
- ],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
@@ -17117,22 +17150,14 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000351"
+ "@value": "nrel00000742"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000678",
+ "@id": "urn:nrel_example/nrel00001144",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000931"
- },
- {
- "@id": "urn:nrel_example/nrel00001256"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -17141,218 +17166,171 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000678"
+ "@value": "nrel00001144"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000371",
+ "@id": "urn:nrel_example/nrel00001194",
"@type": [
- "http://data.ashrae.org/standard223#Pump"
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000723"
- },
- {
- "@id": "urn:nrel_example/nrel00001275"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000033"
- },
- {
- "@id": "urn:nrel_example/nrel00000136"
- },
- {
- "@id": "urn:nrel_example/nrel00000239"
- },
- {
- "@id": "urn:nrel_example/nrel00000385"
- },
- {
- "@id": "urn:nrel_example/nrel00000560"
- },
- {
- "@id": "urn:nrel_example/nrel00000584"
- },
- {
- "@id": "urn:nrel_example/nrel00000928"
- },
- {
- "@id": "urn:nrel_example/nrel00001150"
- },
- {
- "@id": "urn:nrel_example/nrel00001151"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001171"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000371"
+ "@value": "nrel00001194"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001310",
+ "@id": "urn:nrel_example/nrel00000320",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001310"
+ "@value": "nrel00000320"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000611",
+ "@id": "urn:nrel_example/nrel00001231",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000590"
- }
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00001121"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
+ "@id": "urn:nrel_example/nrel00000366"
+ },
{
- "@id": "urn:nrel_example/nrel00000009"
+ "@id": "urn:nrel_example/nrel00000655"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@value": "nrel00000611"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000227",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:nrel_example/nrel00000695"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00001271"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000227"
+ "@value": "nrel00001231"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000304",
+ "@id": "urn:nrel_example/nrel00000708",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
+ "@id": "urn:nrel_example/nrel00000939"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "urn:nrel_example/nrel00000345"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000866"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000304"
+ "@value": "nrel00000708"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000278",
+ "@id": "urn:nrel_example/nrel00000427",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000278"
+ "@value": "nrel00000427"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000547",
+ "@id": "urn:nrel_example/nrel00000999",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000547"
+ "@value": "nrel00000999"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000467",
+ "@id": "urn:nrel_example/nrel00000308",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000467"
+ "@value": "nrel00000308"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000388",
+ "@id": "urn:nrel_example/nrel00000364",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000388"
+ "@value": "nrel00000364"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001124",
+ "@id": "urn:nrel_example/nrel00001097",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
@@ -17361,86 +17339,111 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001124"
+ "@value": "nrel00001097"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001056",
+ "@id": "urn:nrel_example/nrel00000729",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Fan"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000018"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000619"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00001265"
+ "@id": "urn:nrel_example/nrel00000023"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000060"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000201"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000232"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000614"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000843"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000878"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000886"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000926"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001083"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001146"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001056"
+ "@value": "nrel00000729"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001307",
+ "@id": "urn:nrel_example/nrel00000550",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Energy"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/KiloW-HR"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001307"
+ "@value": "nrel00000550"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000696",
+ "@id": "urn:nrel_example/nrel00001087",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Filter"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000107"
+ },
{
- "@value": "nrel00000696"
+ "@id": "urn:nrel_example/nrel00000908"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00001270",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00001213"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001270"
+ "@value": "nrel00001087"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001306",
+ "@id": "urn:nrel_example/nrel00000404",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -17456,211 +17459,221 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001306"
+ "@value": "nrel00000404"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000360",
+ "@id": "urn:nrel_example/nrel00001136",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000360"
+ "@value": "nrel00001136"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000715",
+ "@id": "urn:nrel_example/nrel00001132",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000715"
+ "@value": "nrel00001132"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000091",
+ "@id": "urn:nrel_example/nrel00000218",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/Energy"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/KiloW-HR"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000091"
+ "@value": "nrel00000218"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000289",
+ "@id": "urn:nrel_example/nrel00000412",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/A"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000289"
+ "@value": "nrel00000412"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000357",
+ "@id": "urn:nrel_example/nrel00000713",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/Energy"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/KiloW-HR"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000357"
+ "@value": "nrel00000713"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000426",
+ "@id": "urn:nrel_example/nrel00000542",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000971"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001144"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000426"
+ "@value": "nrel00000542"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000792",
+ "@id": "urn:nrel_example/nrel00001082",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000792"
+ "@value": "nrel00001082"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001142",
+ "@id": "urn:nrel_example/nrel00000156",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000266"
- },
- {
- "@id": "urn:nrel_example/nrel00000472"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000934"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
}
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000104"
- },
- {
- "@id": "urn:nrel_example/nrel00000620"
- },
- {
- "@id": "urn:nrel_example/nrel00001141"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001241"
+ "@id": "http://qudt.org/vocab/unit/A"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000256"
- },
+ "@value": "nrel00000156"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000463",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000260"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001142"
+ "@value": "nrel00000463"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000186",
+ "@id": "urn:nrel_example/nrel00000483",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000862"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ {
+ "@id": "urn:nrel_example/nrel00000464"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00001134"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000186"
+ "@value": "nrel00000483"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000490",
+ "@id": "urn:nrel_example/nrel00000995",
"@type": [
"http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00001020"
+ "@id": "urn:nrel_example/nrel00000131"
},
{
- "@id": "urn:nrel_example/nrel00001200"
+ "@id": "urn:nrel_example/nrel00001259"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -17670,28 +17683,28 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000490"
+ "@value": "nrel00000995"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001073",
+ "@id": "urn:nrel_example/nrel00000507",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-FlowStatus"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001073"
+ "@value": "nrel00000507"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001011",
+ "@id": "urn:nrel_example/nrel00000673",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -17707,70 +17720,65 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001011"
+ "@value": "nrel00000673"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000398",
+ "@id": "urn:nrel_example/nrel00000662",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000398"
+ "@value": "nrel00000662"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000637",
+ "@id": "urn:nrel_example/nrel00000646",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/Frequency"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/HZ"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000637"
+ "@value": "nrel00000646"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001191",
+ "@id": "urn:nrel_example/nrel00000583",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001191"
+ "@value": "nrel00000583"
}
]
},
@@ -17802,265 +17810,341 @@
]
},
{
- "@id": "urn:nrel_example/nrel00000137",
+ "@id": "urn:nrel_example/nrel00000893",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000810"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000623"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000137"
+ "@value": "nrel00000893"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000169",
+ "@id": "urn:nrel_example/nrel00001158",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@value": "nrel00000169"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00001158"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001168",
+ "@id": "urn:nrel_example/nrel00000727",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001168"
+ "@value": "nrel00000727"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000753",
+ "@id": "urn:nrel_example/nrel00000287",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000753"
+ "@value": "nrel00000287"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000856",
+ "@id": "urn:nrel_example/nrel00000494",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000045"
- }
- ],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
- {
- "@id": "urn:nrel_example/nrel00000969"
+ "@id": "urn:nrel_example/nrel00001023"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00000610"
+ "@id": "urn:nrel_example/nrel00000081"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000856"
+ "@value": "nrel00000494"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000764",
+ "@id": "urn:nrel_example/nrel00001030",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000764"
+ "@value": "nrel00001030"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000375",
+ "@id": "urn:nrel_example/nrel00001106",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-FlowStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000375"
+ "@value": "nrel00001106"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000199",
+ "@id": "urn:nrel_example/nrel00001297",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#TerminalUnit"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:nrel_example/nrel00000084"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000230"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000693"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000815"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000881"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:nrel_example/nrel00001123"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001194"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000373"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000544"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001022"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000199"
+ "@value": "nrel00001297"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000470",
+ "@id": "urn:nrel_example/nrel00001049",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001267"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00001165"
+ "@value": "nrel00001049"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001267",
+ "@type": [
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "urn:nrel_example/nrel00000186"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000236"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000245"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000339"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000444"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000627"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasDomain": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000184"
+ },
{
"@id": "urn:nrel_example/nrel00000743"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000470"
+ "@value": "nrel00001267"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001286",
+ "@id": "urn:nrel_example/nrel00000297",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@value": "nrel00000297"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000952",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ {
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001286"
+ "@value": "nrel00000952"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001058",
+ "@id": "urn:nrel_example/nrel00000246",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "urn:nrel_example/nrel00000649"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ {
+ "@id": "urn:nrel_example/nrel00000553"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000182"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001058"
+ "@value": "nrel00000246"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001304",
+ "@id": "urn:nrel_example/nrel00000623",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001304"
+ "@value": "nrel00000623"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000569",
+ "@id": "urn:nrel_example/nrel00000565",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000569"
+ "@value": "nrel00000565"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001137",
+ "@id": "urn:nrel_example/nrel00001081",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
@@ -18071,238 +18155,296 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001137"
+ "@value": "nrel00001081"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000924",
+ "@id": "urn:nrel_example/nrel00001010",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000924"
+ "@value": "nrel00001010"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000262",
+ "@id": "urn:nrel_example/nrel00000315",
"@type": [
- "http://data.ashrae.org/standard223#FanCoilUnit"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000035"
- },
- {
- "@id": "urn:nrel_example/nrel00000505"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000729"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000597"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000724"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000070"
- },
+ "@value": "nrel00000315"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000717",
+ "@type": [
+ "http://data.ashrae.org/standard223#Sensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000405"
- },
+ "@id": "urn:nrel_example/nrel00000122"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "urn:nrel_example/nrel00000551"
- },
+ "@id": "urn:nrel_example/nrel00001027"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00000980"
- },
+ "@id": "urn:nrel_example/nrel00001167"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00001011"
+ "@value": "nrel00000717"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000991",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Cooling"
- },
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "urn:nrel_example/nrel00001194"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000262"
+ "@value": "nrel00000991"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001132",
+ "@id": "urn:nrel_example/nrel00000220",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001132"
+ "@value": "nrel00000220"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001297",
+ "@id": "urn:nrel_example/nrel00000462",
"@type": [
- "http://data.ashrae.org/standard223#TerminalUnit"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000084"
- },
- {
- "@id": "urn:nrel_example/nrel00000230"
- },
- {
- "@id": "urn:nrel_example/nrel00000693"
- },
- {
- "@id": "urn:nrel_example/nrel00000815"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000881"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00001123"
- },
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00001194"
+ "@value": "nrel00000462"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000948",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000373"
- },
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000544"
- },
+ "@value": "nrel00000948"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000715",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001022"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001297"
+ "@value": "nrel00000715"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000571",
+ "@id": "urn:nrel_example/nrel00000270",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Frequency"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/HZ"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000571"
+ "@value": "nrel00000270"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001042",
+ "@id": "urn:nrel_example/nrel00000133",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
+ "http://data.ashrae.org/standard223#Sensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "urn:nrel_example/nrel00000432"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00001235"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000133"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000084",
+ "@type": [
+ "http://data.ashrae.org/standard223#HeatingCoil"
+ ],
+ "http://data.ashrae.org/standard223#contains": [
+ {
+ "@id": "urn:nrel_example/nrel00000133"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000593"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000772"
+ }
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000530"
+ "@id": "urn:nrel_example/nrel00000151"
},
{
- "@id": "urn:nrel_example/nrel00000834"
+ "@id": "urn:nrel_example/nrel00000167"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000432"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000991"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000606"
+ "@id": "urn:nrel_example/nrel00000978"
},
{
- "@id": "urn:nrel_example/nrel00001124"
+ "@id": "urn:nrel_example/nrel00001235"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001042"
+ "@value": "nrel00000084"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000766",
+ "@id": "urn:nrel_example/nrel00000033",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000766"
+ "@value": "nrel00000033"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000655",
+ "@id": "urn:nrel_example/nrel00001092",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000539"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000763"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000688"
+ "@id": "urn:nrel_example/nrel00000436"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001225"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000655"
+ "@value": "nrel00001092"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000876",
+ "@id": "urn:nrel_example/nrel00000278",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -18311,212 +18453,237 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000876"
+ "@value": "nrel00000278"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000235",
+ "@id": "urn:nrel_example/nrel00000365",
"@type": [
- "http://data.ashrae.org/standard223#Fan"
+ "http://data.ashrae.org/standard223#FanCoilUnit"
],
"http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:nrel_example/nrel00000413"
+ "@id": "urn:nrel_example/nrel00000580"
},
{
- "@id": "urn:nrel_example/nrel00000887"
+ "@id": "urn:nrel_example/nrel00000630"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001174"
}
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00001161"
+ "@id": "urn:nrel_example/nrel00000001"
},
{
- "@id": "urn:nrel_example/nrel00001311"
+ "@id": "urn:nrel_example/nrel00000459"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000231"
- },
- {
- "@id": "urn:nrel_example/nrel00000294"
- },
- {
- "@id": "urn:nrel_example/nrel00000575"
- },
- {
- "@id": "urn:nrel_example/nrel00000766"
- },
- {
- "@id": "urn:nrel_example/nrel00000835"
+ "@id": "urn:nrel_example/nrel00000157"
},
{
- "@id": "urn:nrel_example/nrel00000951"
+ "@id": "urn:nrel_example/nrel00000425"
},
{
- "@id": "urn:nrel_example/nrel00001177"
+ "@id": "urn:nrel_example/nrel00000672"
},
{
- "@id": "urn:nrel_example/nrel00001202"
+ "@id": "urn:nrel_example/nrel00001109"
},
{
- "@id": "urn:nrel_example/nrel00001216"
- },
+ "@id": "urn:nrel_example/nrel00001314"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "urn:nrel_example/nrel00001281"
+ "@id": "http://data.ashrae.org/standard223#Role-Cooling"
},
{
- "@id": "urn:nrel_example/nrel00001332"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000235"
+ "@value": "nrel00000365"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000712",
+ "@id": "urn:nrel_example/nrel00001247",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@value": "nrel00000712"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000164",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000164"
+ "@value": "nrel00001247"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000145",
+ "@id": "urn:nrel_example/nrel00000140",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@value": "nrel00000145"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000401",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000401"
+ "@value": "nrel00000140"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000151",
+ "@id": "urn:nrel_example/nrel00000408",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000151"
+ "@value": "nrel00000408"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000180",
+ "@id": "urn:nrel_example/nrel00000170",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Frequency"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/HZ"
+ "@id": "http://qudt.org/vocab/unit/KiloW"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000180"
+ "@value": "nrel00000170"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000578",
+ "@id": "urn:nrel_example/nrel00001305",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Junction"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:nrel_example/nrel00000399"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000438"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000603"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000640"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000775"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000806"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000924"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000942"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000947"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001007"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001068"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001080"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001193"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000578"
+ "@value": "nrel00001305"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001173",
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-FlowStatus",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Class",
+ "http://data.ashrae.org/standard223#EnumerationKind-FlowStatus",
+ "http://www.w3.org/ns/shacl#NodeShape"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Energy"
+ "@value": "EnumerationKind FlowStatus"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://www.w3.org/2000/01/rdf-schema#subClassOf": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW-HR"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000078",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001173"
+ "@value": "nrel00000078"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000184",
+ "@id": "urn:nrel_example/nrel00001313",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -18532,74 +18699,61 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000184"
+ "@value": "nrel00001313"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000901",
+ "@id": "urn:nrel_example/nrel00000958",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#TerminalUnit"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000152"
+ },
{
- "@value": "nrel00000901"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000003",
- "@type": [
- "http://data.ashrae.org/standard223#HeatingCoil"
- ],
- "http://data.ashrae.org/standard223#contains": [
+ "@id": "urn:nrel_example/nrel00000521"
+ },
{
- "@id": "urn:nrel_example/nrel00000804"
+ "@id": "urn:nrel_example/nrel00000591"
},
{
- "@id": "urn:nrel_example/nrel00001038"
+ "@id": "urn:nrel_example/nrel00000628"
},
{
- "@id": "urn:nrel_example/nrel00001156"
+ "@id": "urn:nrel_example/nrel00001155"
}
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000612"
- },
- {
- "@id": "urn:nrel_example/nrel00000676"
- },
- {
- "@id": "urn:nrel_example/nrel00000897"
+ "@id": "urn:nrel_example/nrel00000208"
},
{
- "@id": "urn:nrel_example/nrel00000953"
+ "@id": "urn:nrel_example/nrel00000354"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000203"
+ "@id": "urn:nrel_example/nrel00000139"
},
{
- "@id": "urn:nrel_example/nrel00000895"
+ "@id": "urn:nrel_example/nrel00000823"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000985"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000003"
+ "@value": "nrel00000958"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000347",
+ "@id": "urn:nrel_example/nrel00000316",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
@@ -18608,137 +18762,113 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000347"
+ "@value": "nrel00000316"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001252",
+ "@id": "urn:nrel_example/nrel00001315",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00000441"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000132"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001252"
+ "@value": "nrel00001315"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001321",
+ "@id": "urn:nrel_example/nrel00000581",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000265"
+ "@id": "urn:nrel_example/nrel00000223"
},
{
- "@id": "urn:nrel_example/nrel00000876"
+ "@id": "urn:nrel_example/nrel00000320"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000403"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000850"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001321"
+ "@value": "nrel00000581"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000627",
+ "@id": "urn:nrel_example/nrel00000393",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000627"
+ "@value": "nrel00000393"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000814",
+ "@id": "urn:nrel_example/nrel00000459",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000814"
+ "@value": "nrel00000459"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000126",
+ "@id": "urn:nrel_example/nrel00000259",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ "@id": "http://qudt.org/vocab/quantitykind/Frequency"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW"
+ "@id": "http://qudt.org/vocab/unit/HZ"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000126"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00001125",
- "@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00001064"
- },
- {
- "@id": "urn:nrel_example/nrel00001259"
- }
- ],
- "http://data.ashrae.org/standard223#hasDomain": [
- {
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000002"
- },
- {
- "@id": "urn:nrel_example/nrel00001280"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00001125"
+ "@value": "nrel00000259"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000333",
+ "@id": "urn:nrel_example/nrel00001220",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -18754,122 +18884,131 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000333"
+ "@value": "nrel00001220"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000854",
+ "@id": "urn:nrel_example/nrel00000707",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#Pump"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000781"
- }
- ],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "@id": "urn:nrel_example/nrel00000735"
+ },
{
- "@id": "urn:nrel_example/nrel00001027"
+ "@id": "urn:nrel_example/nrel00001172"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000537"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000086"
+ },
{
- "@value": "nrel00000854"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00001121",
- "@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
- ],
- "http://data.ashrae.org/standard223#encloses": [
+ "@id": "urn:nrel_example/nrel00000089"
+ },
{
- "@id": "urn:nrel_example/nrel00001197"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "@id": "urn:nrel_example/nrel00000129"
+ },
{
- "@id": "urn:nrel_example/nrel00000009"
+ "@id": "urn:nrel_example/nrel00000326"
},
{
- "@id": "urn:nrel_example/nrel00000068"
+ "@id": "urn:nrel_example/nrel00000513"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000659"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000728"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001098"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001110"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001237"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001121"
+ "@value": "nrel00000707"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000590",
+ "@id": "urn:nrel_example/nrel00000147",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000590"
+ "@value": "nrel00000147"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000648",
+ "@id": "urn:nrel_example/nrel00000426",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Frequency"
+ "@id": "urn:nrel_example/nrel00000971"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001144"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/HZ"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000648"
+ "@value": "nrel00000426"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000068",
+ "@id": "urn:nrel_example/nrel00000764",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000068"
+ "@value": "nrel00000764"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000016",
+ "@id": "urn:nrel_example/nrel00001271",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
@@ -18878,33 +19017,28 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000016"
+ "@value": "nrel00001271"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001059",
+ "@id": "urn:nrel_example/nrel00001051",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001059"
+ "@value": "nrel00001051"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000727",
+ "@id": "urn:nrel_example/nrel00000571",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -18920,75 +19054,70 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000727"
+ "@value": "nrel00000571"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000107",
+ "@id": "urn:nrel_example/nrel00000734",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000875"
+ "@id": "urn:nrel_example/nrel00000075"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000740"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000107"
+ "@value": "nrel00000734"
}
]
},
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Overridden",
+ "@id": "urn:nrel_example/nrel00000194",
"@type": [
- "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus",
- "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@language": "en",
- "@value": "AlarmStatus-Ok"
- },
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@language": "en",
- "@value": "Override-Overridden"
+ "@value": "nrel00000194"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000989",
+ "@id": "urn:nrel_example/nrel00000036",
"@type": [
- "http://data.ashrae.org/standard223#Zone"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasDomainSpace": [
- {
- "@id": "urn:nrel_example/nrel00000649"
- },
- {
- "@id": "urn:nrel_example/nrel00000818"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000939"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000941"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000989"
+ "@value": "nrel00000036"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000366",
+ "@id": "urn:nrel_example/nrel00000781",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -18999,33 +19128,33 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000366"
+ "@value": "nrel00000781"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001228",
+ "@id": "urn:nrel_example/nrel00001110",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000227"
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001228"
+ "@value": "nrel00001110"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000723",
+ "@id": "urn:nrel_example/nrel00000026",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -19036,144 +19165,149 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000723"
+ "@value": "nrel00000026"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000477",
+ "@id": "urn:nrel_example/nrel00001253",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/KiloW"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000477"
+ "@value": "nrel00001253"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000268",
+ "@id": "urn:nrel_example/nrel00000935",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@value": "nrel00000268"
+ "@id": "http://qudt.org/vocab/unit/V"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000935"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001016",
+ "@id": "urn:nrel_example/nrel00000931",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "urn:nrel_example/nrel00000678"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001016"
+ "@value": "nrel00000931"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000319",
+ "@id": "urn:nrel_example/nrel00000697",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000319"
+ "@value": "nrel00000697"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000667",
+ "@id": "urn:nrel_example/nrel00000293",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000207"
+ "@id": "urn:nrel_example/nrel00001069"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00000443"
+ "@id": "urn:nrel_example/nrel00000419"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000667"
+ "@value": "nrel00000293"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001192",
+ "@id": "urn:nrel_example/nrel00000554",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001192"
+ "@value": "nrel00000554"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000316",
+ "@id": "urn:nrel_example/nrel00000975",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000316"
+ "@value": "nrel00000975"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000441",
+ "@id": "urn:nrel_example/nrel00000720",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -19182,186 +19316,175 @@
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00000441"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000745",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000441"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000745"
+ "@value": "nrel00000720"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000312",
+ "@id": "urn:nrel_example/nrel00000820",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000869"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001228"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000047"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000196"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000312"
+ "@value": "nrel00000820"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000532",
+ "@id": "urn:nrel_example/nrel00000382",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000532"
+ "@value": "nrel00000382"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000256",
+ "@id": "urn:nrel_example/nrel00000939",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:nrel_example/nrel00000281"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000474"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000308"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001090"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000256"
+ "@value": "nrel00000939"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000225",
+ "@id": "urn:nrel_example/nrel00000617",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000225"
+ "@value": "nrel00000617"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000339",
+ "@id": "urn:nrel_example/nrel00000866",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@value": "nrel00000339"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000066",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000066"
+ "@value": "nrel00000866"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000700",
+ "@id": "urn:nrel_example/nrel00000469",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000700"
+ "@value": "nrel00000469"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000752",
+ "@id": "urn:nrel_example/nrel00000031",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:nrel_example/nrel00000840"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000858"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:nrel_example/nrel00000268"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000598"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000752"
+ "@value": "nrel00000031"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000456",
+ "@id": "urn:nrel_example/nrel00000562",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -19375,28 +19498,12 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000456"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00001040",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00001040"
+ "@value": "nrel00000562"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000465",
+ "@id": "urn:nrel_example/nrel00001250",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -19407,37 +19514,37 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000465"
+ "@value": "nrel00001250"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000512",
+ "@id": "urn:nrel_example/nrel00001268",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000512"
+ "@value": "nrel00001268"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000731",
+ "@id": "urn:nrel_example/nrel00000130",
"@type": [
"http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000640"
+ "@id": "urn:nrel_example/nrel00000380"
},
{
- "@id": "urn:nrel_example/nrel00001270"
+ "@id": "urn:nrel_example/nrel00000579"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -19447,240 +19554,204 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000731"
+ "@value": "nrel00000130"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001186",
+ "@id": "urn:nrel_example/nrel00000204",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000074"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001208"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001186"
+ "@value": "nrel00000204"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000964",
+ "@id": "urn:nrel_example/nrel00000947",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000964"
+ "@value": "nrel00000947"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001226",
+ "@id": "urn:nrel_example/nrel00000405",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001226"
+ "@value": "nrel00000405"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000721",
+ "@id": "urn:nrel_example/nrel00001098",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Energy"
+ "@id": "http://qudt.org/vocab/quantitykind/Frequency"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW-HR"
+ "@id": "http://qudt.org/vocab/unit/HZ"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000721"
+ "@value": "nrel00001098"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000770",
+ "@id": "urn:nrel_example/nrel00000169",
"@type": [
- "http://data.ashrae.org/standard223#Fan"
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000882"
- },
- {
- "@id": "urn:nrel_example/nrel00001192"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000143"
- },
- {
- "@id": "urn:nrel_example/nrel00000244"
- },
- {
- "@id": "urn:nrel_example/nrel00000276"
- },
- {
- "@id": "urn:nrel_example/nrel00000311"
- },
- {
- "@id": "urn:nrel_example/nrel00000624"
- },
- {
- "@id": "urn:nrel_example/nrel00000753"
- },
- {
- "@id": "urn:nrel_example/nrel00000943"
- },
- {
- "@id": "urn:nrel_example/nrel00001035"
- },
- {
- "@id": "urn:nrel_example/nrel00001055"
- },
- {
- "@id": "urn:nrel_example/nrel00001309"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001322"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000770"
+ "@value": "nrel00000169"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001019",
+ "@id": "urn:nrel_example/nrel00000076",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "urn:nrel_example/nrel00001047"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001019"
+ "@value": "nrel00000076"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001099",
+ "@id": "urn:nrel_example/nrel00000951",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001099"
+ "@value": "nrel00000951"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000840",
+ "@id": "urn:nrel_example/nrel00000696",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000840"
+ "@value": "nrel00000696"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000582",
+ "@id": "urn:nrel_example/nrel00001022",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001040"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000571"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000582"
+ "@value": "nrel00001022"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000795",
+ "@id": "urn:nrel_example/nrel00000493",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:nrel_example/nrel00000587"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:nrel_example/nrel00000160"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000844"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000795"
+ "@value": "nrel00000493"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001133",
+ "@id": "urn:nrel_example/nrel00000548",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
@@ -19689,30 +19760,35 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001133"
+ "@value": "nrel00000548"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000257",
+ "@id": "urn:nrel_example/nrel00001230",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000257"
+ "@value": "nrel00001230"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001018",
+ "@id": "urn:nrel_example/nrel00000784",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -19721,170 +19797,170 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001018"
+ "@value": "nrel00000784"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000948",
+ "@id": "urn:nrel_example/nrel00000342",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000967"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00001221"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000948"
+ "@value": "nrel00000342"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000072",
+ "@id": "urn:nrel_example/nrel00000889",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@value": "nrel00000889"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001284",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:nrel_example/nrel00000961"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000072"
+ "@value": "nrel00001284"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000089",
+ "@id": "urn:nrel_example/nrel00000368",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000089"
+ "@value": "nrel00000368"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001013",
+ "@id": "urn:nrel_example/nrel00000633",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001013"
+ "@value": "nrel00000633"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000882",
+ "@id": "urn:nrel_example/nrel00000577",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:nrel_example/nrel00000891"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000687"
+ }
+ ],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000882"
+ "@value": "nrel00000577"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000575",
+ "@id": "urn:nrel_example/nrel00001048",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/IN_H2O"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000575"
+ "@value": "nrel00001048"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000021",
+ "@id": "urn:nrel_example/nrel00001259",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000339"
- }
- ],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
- {
- "@id": "urn:nrel_example/nrel00001165"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
- {
- "@id": "urn:nrel_example/nrel00000637"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00000021"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000551",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000551"
+ "@value": "nrel00001259"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000827",
+ "@id": "urn:nrel_example/nrel00000487",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -19895,191 +19971,119 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000827"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000157",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
- {
- "@id": "http://qudt.org/vocab/unit/DEG_C"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00000157"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00001324",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
- {
- "@id": "http://qudt.org/vocab/unit/DEG_C"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00001324"
+ "@value": "nrel00000487"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000382",
+ "@id": "urn:nrel_example/nrel00000235",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Fan"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000413"
+ },
{
- "@value": "nrel00000382"
+ "@id": "urn:nrel_example/nrel00000887"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000271",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00001161"
+ },
{
- "@value": "nrel00000271"
+ "@id": "urn:nrel_example/nrel00001311"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000904",
- "@type": [
- "http://data.ashrae.org/standard223#CoolingCoil"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000112"
+ "@id": "urn:nrel_example/nrel00000231"
},
{
- "@id": "urn:nrel_example/nrel00000123"
- }
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "@id": "urn:nrel_example/nrel00000294"
+ },
{
- "@id": "urn:nrel_example/nrel00000248"
+ "@id": "urn:nrel_example/nrel00000575"
},
{
- "@id": "urn:nrel_example/nrel00000874"
+ "@id": "urn:nrel_example/nrel00000766"
},
{
- "@id": "urn:nrel_example/nrel00000973"
+ "@id": "urn:nrel_example/nrel00000835"
},
{
- "@id": "urn:nrel_example/nrel00000996"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "@id": "urn:nrel_example/nrel00000951"
+ },
{
- "@id": "urn:nrel_example/nrel00000140"
+ "@id": "urn:nrel_example/nrel00001177"
},
{
- "@id": "urn:nrel_example/nrel00000298"
+ "@id": "urn:nrel_example/nrel00001202"
},
{
- "@id": "urn:nrel_example/nrel00000330"
+ "@id": "urn:nrel_example/nrel00001216"
},
{
- "@id": "urn:nrel_example/nrel00001239"
+ "@id": "urn:nrel_example/nrel00001281"
},
{
- "@id": "urn:nrel_example/nrel00001317"
+ "@id": "urn:nrel_example/nrel00001332"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000904"
+ "@value": "nrel00000235"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000248",
+ "@id": "urn:nrel_example/nrel00000413",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Damper"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000927"
+ },
{
- "@value": "nrel00000248"
+ "@id": "urn:nrel_example/nrel00000950"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000821",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:nrel_example/nrel00000013"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000103"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000821"
+ "@value": "nrel00000413"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001169",
+ "@id": "urn:nrel_example/nrel00000221",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:nrel_example/nrel00000635"
- }
- ],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001169"
+ "@value": "nrel00000221"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001144",
+ "@id": "urn:nrel_example/nrel00000970",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -20088,149 +20092,172 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001144"
+ "@value": "nrel00000970"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000933",
+ "@id": "urn:nrel_example/nrel00001191",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000933"
+ "@value": "nrel00001191"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000039",
+ "@id": "urn:nrel_example/nrel00000155",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00001226"
+ "@id": "urn:nrel_example/nrel00000862"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ {
+ "@id": "urn:nrel_example/nrel00000464"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00000933"
+ "@id": "urn:nrel_example/nrel00000417"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000039"
+ "@value": "nrel00000155"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000395",
+ "@id": "urn:nrel_example/nrel00000735",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000395"
+ "@value": "nrel00000735"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000949",
+ "@id": "urn:nrel_example/nrel00000335",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000949"
+ "@value": "nrel00000335"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000293",
+ "@id": "urn:nrel_example/nrel00000778",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001069"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000419"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000293"
+ "@value": "nrel00000778"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001240",
+ "@id": "urn:nrel_example/nrel00000761",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-FlowStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001240"
+ "@value": "nrel00000761"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001296",
+ "@id": "urn:nrel_example/nrel00000447",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#HeatRecoveryCoil"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00001200"
- }
- ],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "@id": "urn:nrel_example/nrel00000660"
+ },
{
- "@id": "urn:nrel_example/nrel00000241"
+ "@id": "urn:nrel_example/nrel00000899"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001166"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001240"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000274"
+ "@id": "urn:nrel_example/nrel00000199"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000542"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000585"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001061"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001296"
+ "@value": "nrel00000447"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000376",
+ "@id": "urn:nrel_example/nrel00000514",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -20241,31 +20268,41 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000376"
+ "@value": "nrel00000514"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000897",
+ "@id": "urn:nrel_example/nrel00000479",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/KiloW"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000897"
+ "@value": "nrel00000479"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000869",
+ "@id": "urn:nrel_example/nrel00000574",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:nrel_example/nrel00001211"
+ }
+ ],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
@@ -20273,58 +20310,74 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000869"
+ "@value": "nrel00000574"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000031",
+ "@id": "urn:nrel_example/nrel00001199",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
+ "http://data.ashrae.org/standard223#Pump"
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000840"
+ "@id": "urn:nrel_example/nrel00000096"
},
{
- "@id": "urn:nrel_example/nrel00000858"
+ "@id": "urn:nrel_example/nrel00001032"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000268"
+ "@id": "urn:nrel_example/nrel00000056"
},
{
- "@id": "urn:nrel_example/nrel00000598"
+ "@id": "urn:nrel_example/nrel00000242"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000277"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000289"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000452"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000559"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000929"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001028"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001066"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001224"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000031"
+ "@value": "nrel00001199"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000517",
+ "@id": "urn:nrel_example/nrel00000606",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000307"
- },
- {
- "@id": "urn:nrel_example/nrel00000618"
- }
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000517"
+ "@value": "nrel00000606"
}
]
},
@@ -20345,149 +20398,139 @@
]
},
{
- "@id": "urn:nrel_example/nrel00000761",
+ "@id": "urn:nrel_example/nrel00000313",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-FlowStatus"
+ "@id": "urn:nrel_example/nrel00000296"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000428"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000066"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001269"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000761"
+ "@value": "nrel00000313"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001000",
+ "@id": "urn:nrel_example/nrel00000869",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001000"
+ "@value": "nrel00000869"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000972",
+ "@id": "urn:nrel_example/nrel00001206",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/A"
+ "@id": "http://qudt.org/vocab/unit/KiloW"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000972"
+ "@value": "nrel00001206"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000596",
+ "@id": "urn:nrel_example/nrel00001027",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:nrel_example/nrel00000122"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@value": "nrel00000596"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000694",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "@id": "urn:nrel_example/nrel00000206"
+ },
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00000537"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000694"
+ "@value": "nrel00001027"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000751",
+ "@id": "urn:nrel_example/nrel00000739",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000138"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000241"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001283"
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000751"
+ "@value": "nrel00000739"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001136",
+ "@id": "urn:nrel_example/nrel00000085",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001136"
+ "@value": "nrel00000085"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001211",
+ "@id": "urn:nrel_example/nrel00000001",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000406"
- },
- {
- "@id": "urn:nrel_example/nrel00000574"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -20496,268 +20539,330 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001211"
+ "@value": "nrel00000001"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000213",
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Class",
+ "http://data.ashrae.org/standard223#EnumerationKind-Override",
+ "http://www.w3.org/ns/shacl#NodeShape"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@value": "EnumerationKind Override"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://www.w3.org/2000/01/rdf-schema#subClassOf": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000846",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000213"
+ "@value": "nrel00000846"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000358",
+ "@id": "urn:nrel_example/nrel00000891",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:nrel_example/nrel00000158"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000577"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000358"
+ "@value": "nrel00000891"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000943",
+ "@id": "urn:nrel_example/nrel00000172",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ "@id": "urn:nrel_example/nrel00000351"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001180"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000943"
+ "@value": "nrel00000172"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000458",
+ "@id": "urn:nrel_example/nrel00000265",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@value": "nrel00000265"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000682",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000458"
+ "@value": "nrel00000682"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001239",
+ "@id": "urn:nrel_example/nrel00000146",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@value": "nrel00000146"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000006",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001239"
+ "@value": "nrel00000006"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000346",
+ "@id": "urn:nrel_example/nrel00001078",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000439"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000873"
+ "@id": "urn:nrel_example/nrel00001077"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000272"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000346"
+ "@value": "nrel00001078"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001290",
+ "@id": "urn:nrel_example/nrel00000698",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001290"
+ "@value": "nrel00000698"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000505",
+ "@id": "urn:nrel_example/nrel00001306",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000626"
- },
- {
- "@id": "urn:nrel_example/nrel00001071"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001266"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000321"
- },
- {
- "@id": "urn:nrel_example/nrel00000748"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000983"
- },
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00001117"
+ "@value": "nrel00001306"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000528",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000936"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001236"
+ "@id": "http://qudt.org/vocab/unit/KiloW"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000505"
+ "@value": "nrel00000528"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001102",
+ "@id": "urn:nrel_example/nrel00000988",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001102"
+ "@value": "nrel00000988"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000635",
+ "@id": "urn:nrel_example/nrel00001104",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000635"
+ "@value": "nrel00001104"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000717",
+ "@id": "urn:nrel_example/nrel00000206",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000122"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001027"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00001167"
+ "@value": "nrel00000206"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000726",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000717"
+ "@value": "nrel00000726"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000701",
+ "@id": "urn:nrel_example/nrel00000346",
"@type": [
"http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00001025"
+ "@id": "urn:nrel_example/nrel00000439"
},
{
- "@id": "urn:nrel_example/nrel00001203"
+ "@id": "urn:nrel_example/nrel00000873"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -20767,246 +20872,242 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000701"
+ "@value": "nrel00000346"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000757",
+ "@id": "urn:nrel_example/nrel00000978",
"@type": [
- "http://data.ashrae.org/standard223#CoolingCoil"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000629"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000872"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000006"
- },
- {
- "@id": "urn:nrel_example/nrel00000015"
- },
- {
- "@id": "urn:nrel_example/nrel00000423"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001112"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000008"
- },
- {
- "@id": "urn:nrel_example/nrel00000545"
- },
- {
- "@id": "urn:nrel_example/nrel00000999"
- },
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00001084"
- },
+ "@value": "nrel00000978"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001269",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00001288"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000757"
+ "@value": "nrel00001269"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000095",
+ "@id": "urn:nrel_example/nrel00000222",
"@type": [
- "http://data.ashrae.org/standard223#TerminalUnit"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000168"
- },
- {
- "@id": "urn:nrel_example/nrel00000312"
- },
- {
- "@id": "urn:nrel_example/nrel00000497"
- },
- {
- "@id": "urn:nrel_example/nrel00000608"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000799"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000227"
- },
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00001265"
+ "@value": "nrel00000222"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001182",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000042"
- },
- {
- "@id": "urn:nrel_example/nrel00000726"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000809"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000095"
+ "@value": "nrel00001182"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000309",
+ "@id": "urn:nrel_example/nrel00000247",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000000"
+ "@id": "urn:nrel_example/nrel00001105"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ {
+ "@id": "urn:nrel_example/nrel00000859"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00001220"
+ "@id": "urn:nrel_example/nrel00000987"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000309"
+ "@value": "nrel00000247"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000881",
+ "@id": "urn:nrel_example/nrel00000677",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001194"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:nrel_example/nrel00000544"
+ "@id": "urn:nrel_example/nrel00000208"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000881"
+ "@value": "nrel00000677"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000134",
+ "@id": "urn:nrel_example/nrel00000919",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000026"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000094"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000134"
+ "@value": "nrel00000919"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000520",
+ "@id": "urn:nrel_example/nrel00000189",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/A"
+ "@id": "urn:nrel_example/nrel00000163"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001094"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:nrel_example/nrel00000211"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000520"
+ "@value": "nrel00000189"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000197",
+ "@id": "urn:nrel_example/nrel00000588",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/A"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000197"
+ "@value": "nrel00000588"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000646",
+ "@id": "urn:nrel_example/nrel00000295",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Frequency"
+ "@id": "http://qudt.org/vocab/quantitykind/Energy"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/HZ"
+ "@id": "http://qudt.org/vocab/unit/KiloW-HR"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000646"
+ "@value": "nrel00000295"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000976",
+ "@id": "urn:nrel_example/nrel00000675",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:nrel_example/nrel00000574"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000691"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000347"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001153"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000976"
+ "@value": "nrel00000675"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000207",
+ "@id": "urn:nrel_example/nrel00000251",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -21017,198 +21118,200 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000207"
+ "@value": "nrel00000251"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000850",
+ "@id": "urn:nrel_example/nrel00001152",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000850"
+ "@value": "nrel00001152"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000391",
+ "@id": "urn:nrel_example/nrel00000290",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000391"
+ "@value": "nrel00000290"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000412",
+ "@id": "urn:nrel_example/nrel00000627",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000412"
+ "@value": "nrel00000627"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001152",
+ "@id": "urn:nrel_example/nrel00000266",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ "@id": "urn:nrel_example/nrel00000620"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "urn:nrel_example/nrel00000260"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001152"
+ "@value": "nrel00000266"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000681",
+ "@id": "urn:nrel_example/nrel00001115",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Pump"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ "@id": "urn:nrel_example/nrel00000014"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000237"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "urn:nrel_example/nrel00000102"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000108"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000327"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000338"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000453"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000633"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000732"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001118"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001148"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001206"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000681"
+ "@value": "nrel00001115"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000008",
+ "@id": "urn:nrel_example/nrel00000802",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000008"
+ "@value": "nrel00000802"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001015",
+ "@id": "urn:nrel_example/nrel00000072",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000487"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001099"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000024"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000979"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001015"
+ "@value": "nrel00000072"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000269",
+ "@id": "urn:nrel_example/nrel00000856",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@value": "nrel00000269"
+ "@id": "urn:nrel_example/nrel00000045"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000934",
- "@type": [
- "http://data.ashrae.org/standard223#Valve"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000153"
- },
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "urn:nrel_example/nrel00000302"
+ "@id": "urn:nrel_example/nrel00000969"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000653"
- },
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00001249"
+ "@id": "urn:nrel_example/nrel00000610"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000934"
+ "@value": "nrel00000856"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000695",
+ "@id": "urn:nrel_example/nrel00000422",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
@@ -21219,135 +21322,109 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000695"
+ "@value": "nrel00000422"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000518",
+ "@id": "urn:nrel_example/nrel00000826",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000518"
+ "@value": "nrel00000826"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000803",
+ "@id": "urn:nrel_example/nrel00000600",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "urn:nrel_example/nrel00000439"
+ },
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:nrel_example/nrel00001049"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@value": "nrel00000803"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000049",
- "@type": [
- "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000165"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
+ "@id": "urn:nrel_example/nrel00000847"
+ },
{
- "@id": "urn:nrel_example/nrel00000175"
+ "@id": "urn:nrel_example/nrel00001059"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000049"
+ "@value": "nrel00000600"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001051",
+ "@id": "urn:nrel_example/nrel00000127",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@value": "nrel00001051"
+ "@id": "urn:nrel_example/nrel00000631"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000661",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
+ "@id": "urn:nrel_example/nrel00000241"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "urn:nrel_example/nrel00001085"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000661"
+ "@value": "nrel00000127"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000744",
+ "@id": "urn:nrel_example/nrel00000128",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Energy"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW-HR"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000744"
+ "@value": "nrel00000128"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000785",
+ "@id": "urn:nrel_example/nrel00000597",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -21356,100 +21433,121 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000785"
+ "@value": "nrel00000597"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000493",
+ "@id": "urn:nrel_example/nrel00001276",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000587"
- }
+ "http://data.ashrae.org/standard223#FanCoilUnit"
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:nrel_example/nrel00000160"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
+ "@id": "urn:nrel_example/nrel00000757"
+ },
{
- "@id": "urn:nrel_example/nrel00000844"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000777"
+ },
{
- "@value": "nrel00000493"
+ "@id": "urn:nrel_example/nrel00001142"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000099",
- "@type": [
- "http://data.ashrae.org/standard223#Fan"
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000297"
+ "@id": "urn:nrel_example/nrel00000100"
},
{
- "@id": "urn:nrel_example/nrel00000541"
+ "@id": "urn:nrel_example/nrel00000873"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000036"
+ "@id": "urn:nrel_example/nrel00000141"
},
{
- "@id": "urn:nrel_example/nrel00000181"
+ "@id": "urn:nrel_example/nrel00000382"
},
{
- "@id": "urn:nrel_example/nrel00000210"
+ "@id": "urn:nrel_example/nrel00000711"
},
{
- "@id": "urn:nrel_example/nrel00000259"
+ "@id": "urn:nrel_example/nrel00000765"
},
{
- "@id": "urn:nrel_example/nrel00000304"
- },
+ "@id": "urn:nrel_example/nrel00000959"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "urn:nrel_example/nrel00000375"
+ "@id": "http://data.ashrae.org/standard223#Role-Cooling"
},
{
- "@id": "urn:nrel_example/nrel00000609"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00001276"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000629",
+ "@type": [
+ "http://data.ashrae.org/standard223#Pump"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "urn:nrel_example/nrel00000318"
},
{
- "@id": "urn:nrel_example/nrel00000690"
+ "@id": "urn:nrel_example/nrel00000393"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000105"
},
{
- "@id": "urn:nrel_example/nrel00000744"
+ "@id": "urn:nrel_example/nrel00000128"
},
{
- "@id": "urn:nrel_example/nrel00000954"
+ "@id": "urn:nrel_example/nrel00000218"
},
{
- "@id": "urn:nrel_example/nrel00001147"
+ "@id": "urn:nrel_example/nrel00000398"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000519"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000528"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000540"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000548"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000702"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001140"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000099"
+ "@value": "nrel00000629"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000699",
+ "@id": "urn:nrel_example/nrel00000841",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000535"
- }
- ],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
@@ -21457,44 +21555,49 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000699"
+ "@value": "nrel00000841"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001182",
+ "@id": "urn:nrel_example/nrel00000992",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000211"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000034"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001182"
+ "@value": "nrel00000992"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000111",
+ "@id": "urn:nrel_example/nrel00001164",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000111"
+ "@value": "nrel00001164"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000070",
+ "@id": "urn:nrel_example/nrel00001314",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
@@ -21505,136 +21608,163 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000070"
+ "@value": "nrel00001314"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000561",
+ "@id": "urn:nrel_example/nrel00000854",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000448"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000921"
+ "@id": "urn:nrel_example/nrel00000781"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "urn:nrel_example/nrel00000106"
- },
+ "@id": "urn:nrel_example/nrel00001027"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00001054"
+ "@id": "urn:nrel_example/nrel00000537"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000561"
+ "@value": "nrel00000854"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001109",
+ "@id": "urn:nrel_example/nrel00001217",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-FlowStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001109"
+ "@value": "nrel00001217"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000880",
+ "@id": "urn:nrel_example/nrel00000746",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#EAU",
+ "http://data.ashrae.org/standard223#Equipment"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00000343"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000429"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000675"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000771"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001003"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001089"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001100"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001119"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "urn:nrel_example/nrel00000050"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000134"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000669"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000853"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000880"
+ "@value": "nrel00000746"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000559",
+ "@id": "urn:nrel_example/nrel00000395",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Energy"
- }
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW-HR"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000559"
+ "@value": "nrel00000395"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000542",
+ "@id": "urn:nrel_example/nrel00000458",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000542"
+ "@value": "nrel00000458"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001259",
+ "@id": "urn:nrel_example/nrel00000231",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001259"
+ "@value": "nrel00000231"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000320",
+ "@id": "urn:nrel_example/nrel00001328",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -21643,35 +21773,35 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000320"
+ "@value": "nrel00001328"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000034",
+ "@id": "urn:nrel_example/nrel00001214",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/IN_H2O"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000034"
+ "@value": "nrel00001214"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001203",
+ "@id": "urn:nrel_example/nrel00000339",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -21680,21 +21810,21 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001203"
+ "@value": "nrel00000339"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000759",
+ "@id": "urn:nrel_example/nrel00001021",
"@type": [
"http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000025"
+ "@id": "urn:nrel_example/nrel00000186"
},
{
- "@id": "urn:nrel_example/nrel00000040"
+ "@id": "urn:nrel_example/nrel00001301"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -21704,299 +21834,326 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000759"
+ "@value": "nrel00001021"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000489",
+ "@id": "urn:nrel_example/nrel00000399",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000489"
+ "@value": "nrel00000399"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000059",
+ "@id": "urn:nrel_example/nrel00000787",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000080"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ {
+ "@id": "urn:nrel_example/nrel00000859"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000319"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000059"
+ "@value": "nrel00000787"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000960",
+ "@id": "urn:nrel_example/nrel00000806",
"@type": [
- "http://data.ashrae.org/standard223#TerminalUnit"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000192"
- },
- {
- "@id": "urn:nrel_example/nrel00000494"
- },
- {
- "@id": "urn:nrel_example/nrel00000531"
- },
- {
- "@id": "urn:nrel_example/nrel00000747"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001008"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000635"
- },
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00001023"
+ "@value": "nrel00000806"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000279",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000081"
- },
- {
- "@id": "urn:nrel_example/nrel00000710"
- },
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00001138"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000960"
+ "@value": "nrel00000279"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000252",
+ "@id": "urn:nrel_example/nrel00001324",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000252"
+ "@value": "nrel00001324"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000261",
+ "@id": "urn:nrel_example/nrel00000057",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000261"
+ "@value": "nrel00000057"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000473",
+ "@id": "urn:nrel_example/nrel00000087",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000473"
+ "@value": "nrel00000087"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001235",
+ "@id": "urn:nrel_example/nrel00000499",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001235"
+ "@value": "nrel00000499"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000962",
+ "@id": "urn:nrel_example/nrel00000521",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00000354"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000139"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000962"
+ "@value": "nrel00000521"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000450",
+ "@id": "urn:nrel_example/nrel00001162",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ "@id": "urn:nrel_example/nrel00000069"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000482"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW"
+ "@id": "urn:nrel_example/nrel00000111"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001319"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000450"
+ "@value": "nrel00001162"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001001",
+ "@id": "urn:nrel_example/nrel00001330",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:nrel_example/nrel00000846"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:nrel_example/nrel00000121"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000576"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001001"
+ "@value": "nrel00001330"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000288",
+ "@id": "urn:nrel_example/nrel00000943",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/KiloW"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000288"
+ "@value": "nrel00000943"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000104",
+ "@id": "urn:nrel_example/nrel00001222",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000104"
+ "@value": "nrel00001222"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000223",
+ "@id": "urn:nrel_example/nrel00000803",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000223"
+ "@value": "nrel00000803"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000367",
+ "@id": "urn:nrel_example/nrel00000379",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000219"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000464"
+ "@value": "nrel00000379"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000227",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000956"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000367"
+ "@value": "nrel00000227"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000444",
+ "@id": "urn:nrel_example/nrel00001302",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -22005,105 +22162,78 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000444"
+ "@value": "nrel00001302"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000523",
+ "@id": "urn:nrel_example/nrel00001298",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000523"
+ "@value": "nrel00001298"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000024",
+ "@id": "urn:nrel_example/nrel00000612",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000024"
+ "@value": "nrel00000612"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000179",
+ "@id": "urn:nrel_example/nrel00000286",
"@type": [
- "http://data.ashrae.org/standard223#Pump"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000178"
- },
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000264"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000041"
- },
- {
- "@id": "urn:nrel_example/nrel00000097"
- },
- {
- "@id": "urn:nrel_example/nrel00000445"
- },
- {
- "@id": "urn:nrel_example/nrel00000646"
- },
- {
- "@id": "urn:nrel_example/nrel00000696"
- },
- {
- "@id": "urn:nrel_example/nrel00000860"
- },
- {
- "@id": "urn:nrel_example/nrel00000990"
- },
- {
- "@id": "urn:nrel_example/nrel00001031"
- },
- {
- "@id": "urn:nrel_example/nrel00001191"
- },
+ "@value": "nrel00000286"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000474",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001230"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000179"
+ "@value": "nrel00000474"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000172",
+ "@id": "urn:nrel_example/nrel00000059",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000351"
- },
- {
- "@id": "urn:nrel_example/nrel00001180"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -22112,321 +22242,360 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000172"
+ "@value": "nrel00000059"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000632",
+ "@id": "urn:nrel_example/nrel00001233",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000632"
+ "@value": "nrel00001233"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000229",
+ "@id": "urn:nrel_example/nrel00000546",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
+ "http://data.ashrae.org/standard223#Equipment"
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000229"
+ "@value": "nrel00000546"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000798",
+ "@id": "urn:nrel_example/nrel00001125",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:nrel_example/nrel00001064"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001259"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasDomain": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000002"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001280"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000798"
+ "@value": "nrel00001125"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000918",
+ "@id": "urn:nrel_example/nrel00000794",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "urn:nrel_example/nrel00001197"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ {
+ "@id": "urn:nrel_example/nrel00001121"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00001306"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000918"
+ "@value": "nrel00000794"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000617",
+ "@id": "urn:nrel_example/nrel00000568",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Fan"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:nrel_example/nrel00000898"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001051"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:nrel_example/nrel00000197"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000292"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000402"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000636"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000697"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000832"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000945"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000981"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001058"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001106"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001201"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000617"
+ "@value": "nrel00000568"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001098",
+ "@id": "urn:nrel_example/nrel00000559",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Frequency"
+ "@id": "http://qudt.org/vocab/quantitykind/Energy"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/HZ"
+ "@id": "http://qudt.org/vocab/unit/KiloW-HR"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001098"
+ "@value": "nrel00000559"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000852",
+ "@id": "urn:nrel_example/nrel00000602",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:nrel_example/nrel00000032"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000358"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000852"
+ "@value": "nrel00000602"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000414",
+ "@id": "urn:nrel_example/nrel00001332",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000207"
+ "@id": "http://qudt.org/vocab/quantitykind/Frequency"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001163"
+ "@id": "http://qudt.org/vocab/unit/HZ"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000414"
+ "@value": "nrel00001332"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000675",
+ "@id": "urn:nrel_example/nrel00001185",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
+ "http://data.ashrae.org/standard223#TerminalUnit"
+ ],
+ "http://data.ashrae.org/standard223#contains": [
+ {
+ "@id": "urn:nrel_example/nrel00000414"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000533"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000667"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000755"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001329"
+ }
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000574"
+ "@id": "urn:nrel_example/nrel00000207"
},
{
- "@id": "urn:nrel_example/nrel00000691"
+ "@id": "urn:nrel_example/nrel00000864"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000347"
+ "@id": "urn:nrel_example/nrel00000443"
},
{
- "@id": "urn:nrel_example/nrel00001153"
+ "@id": "urn:nrel_example/nrel00000709"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001163"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000675"
+ "@value": "nrel00001185"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000902",
+ "@id": "urn:nrel_example/nrel00000392",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000100"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000775"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000902"
+ "@value": "nrel00000392"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000447",
+ "@id": "urn:nrel_example/nrel00000145",
"@type": [
- "http://data.ashrae.org/standard223#HeatRecoveryCoil"
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000660"
- },
- {
- "@id": "urn:nrel_example/nrel00000899"
- },
- {
- "@id": "urn:nrel_example/nrel00001166"
- },
- {
- "@id": "urn:nrel_example/nrel00001240"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000199"
- },
- {
- "@id": "urn:nrel_example/nrel00000542"
- },
- {
- "@id": "urn:nrel_example/nrel00000585"
- },
- {
- "@id": "urn:nrel_example/nrel00001061"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00000447"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000967",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000967"
+ "@value": "nrel00000145"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000061",
+ "@id": "urn:nrel_example/nrel00000533",
"@type": [
- "http://data.ashrae.org/standard223#CoolingCoil"
+ "http://data.ashrae.org/standard223#HeatingCoil"
],
"http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:nrel_example/nrel00000062"
+ "@id": "urn:nrel_example/nrel00000188"
},
{
- "@id": "urn:nrel_example/nrel00001199"
+ "@id": "urn:nrel_example/nrel00000418"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001012"
}
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000240"
+ "@id": "urn:nrel_example/nrel00000485"
},
{
- "@id": "urn:nrel_example/nrel00000586"
+ "@id": "urn:nrel_example/nrel00000579"
},
{
- "@id": "urn:nrel_example/nrel00000964"
+ "@id": "urn:nrel_example/nrel00001285"
},
{
- "@id": "urn:nrel_example/nrel00001268"
+ "@id": "urn:nrel_example/nrel00001299"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000498"
- },
- {
- "@id": "urn:nrel_example/nrel00000529"
- },
- {
- "@id": "urn:nrel_example/nrel00000718"
- },
- {
- "@id": "urn:nrel_example/nrel00001158"
+ "@id": "urn:nrel_example/nrel00000166"
},
{
- "@id": "urn:nrel_example/nrel00001261"
+ "@id": "urn:nrel_example/nrel00000457"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000061"
+ "@value": "nrel00000533"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000535",
+ "@id": "urn:nrel_example/nrel00000296",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000691"
- },
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000699"
+ "@value": "nrel00000296"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001135",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -22435,112 +22604,136 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000535"
+ "@value": "nrel00001135"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000978",
+ "@id": "urn:nrel_example/nrel00000014",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000978"
+ "@value": "nrel00000014"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000253",
+ "@id": "urn:nrel_example/nrel00000217",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:nrel_example/nrel00000161"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:nrel_example/nrel00000565"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000253"
+ "@value": "nrel00000217"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000239",
+ "@id": "urn:nrel_example/nrel00000122",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Frequency"
+ "@id": "urn:nrel_example/nrel00000074"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000781"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://qudt.org/vocab/unit/HZ"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000335"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001167"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000239"
+ "@value": "nrel00000122"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000250",
+ "@id": "urn:nrel_example/nrel00000280",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#FanCoilUnit"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ "@id": "urn:nrel_example/nrel00000003"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000055"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000848"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/unit/IN_H2O"
+ "@id": "urn:nrel_example/nrel00000278"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001157"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@value": "nrel00000250"
+ "@id": "urn:nrel_example/nrel00000988"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001152"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001204"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001244"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001282"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000463",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Role-Cooling"
+ },
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000463"
+ "@value": "nrel00000280"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001159",
+ "@id": "urn:nrel_example/nrel00000134",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -22551,57 +22744,70 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001159"
+ "@value": "nrel00000134"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000121",
+ "@id": "urn:nrel_example/nrel00000531",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000941"
+ "@id": "urn:nrel_example/nrel00001023"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000071"
- },
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00000576"
+ "@id": "urn:nrel_example/nrel00001138"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000121"
+ "@value": "nrel00000531"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000048",
+ "@id": "urn:nrel_example/nrel00000795",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000048"
+ "@value": "nrel00000795"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000537",
+ "@id": "urn:nrel_example/nrel00000621",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000621"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000680",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -22617,59 +22823,49 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000537"
+ "@value": "nrel00000680"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001185",
+ "@id": "urn:nrel_example/nrel00000369",
"@type": [
- "http://data.ashrae.org/standard223#TerminalUnit"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000414"
- },
- {
- "@id": "urn:nrel_example/nrel00000533"
- },
- {
- "@id": "urn:nrel_example/nrel00000667"
- },
- {
- "@id": "urn:nrel_example/nrel00000755"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00001329"
+ "@id": "urn:nrel_example/nrel00000441"
}
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000207"
- },
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00000864"
+ "@id": "urn:nrel_example/nrel00000758"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000443"
- },
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000709"
- },
+ "@value": "nrel00000369"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000355",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001163"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001185"
+ "@value": "nrel00000355"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000325",
+ "@id": "urn:nrel_example/nrel00001287",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -22685,195 +22881,210 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000325"
+ "@value": "nrel00001287"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000343",
+ "@id": "urn:nrel_example/nrel00001281",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000134"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000669"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000343"
+ "@value": "nrel00001281"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001045",
+ "@id": "urn:nrel_example/nrel00001243",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Frequency"
+ "@id": "urn:nrel_example/nrel00000281"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "http://qudt.org/vocab/unit/HZ"
+ "@id": "urn:nrel_example/nrel00000708"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000866"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001045"
+ "@value": "nrel00001243"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001266",
+ "@id": "urn:nrel_example/nrel00000586",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000321"
+ "@id": "urn:nrel_example/nrel00000642"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000936"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001266"
+ "@value": "nrel00000586"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001105",
+ "@id": "urn:nrel_example/nrel00000256",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001105"
+ "@value": "nrel00000256"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001311",
+ "@id": "urn:nrel_example/nrel00001289",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/A"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001311"
+ "@value": "nrel00001289"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001281",
+ "@id": "urn:nrel_example/nrel00000518",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001281"
+ "@value": "nrel00000518"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000433",
+ "@id": "urn:nrel_example/nrel00001272",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "http://qudt.org/vocab/unit/IN_H2O"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000433"
+ "@value": "nrel00001272"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001050",
+ "@id": "urn:nrel_example/nrel00000582",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:nrel_example/nrel00001040"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000571"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001050"
+ "@value": "nrel00000582"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000311",
+ "@id": "urn:nrel_example/nrel00000663",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000311"
+ "@value": "nrel00000663"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000605",
+ "@id": "urn:nrel_example/nrel00000768",
"@type": [
"http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000151"
+ "@id": "urn:nrel_example/nrel00001047"
},
{
- "@id": "urn:nrel_example/nrel00001229"
+ "@id": "urn:nrel_example/nrel00001068"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -22883,107 +23094,142 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000605"
+ "@value": "nrel00000768"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000345",
+ "@id": "urn:nrel_example/nrel00001023",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@value": "nrel00001023"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000397",
+ "@type": [
+ "http://data.ashrae.org/standard223#Duct"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:nrel_example/nrel00000255"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000908"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000345"
+ "@value": "nrel00000397"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000687",
+ "@id": "urn:nrel_example/nrel00000835",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Energy"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/KiloW-HR"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000687"
+ "@value": "nrel00000835"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000862",
+ "@id": "urn:nrel_example/nrel00000815",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#Valve"
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000219"
+ "@id": "urn:nrel_example/nrel00001033"
},
{
- "@id": "urn:nrel_example/nrel00000792"
- }
- ],
- "http://data.ashrae.org/standard223#hasDomain": [
- {
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "urn:nrel_example/nrel00001229"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000417"
+ "@id": "urn:nrel_example/nrel00000762"
},
{
- "@id": "urn:nrel_example/nrel00001134"
+ "@id": "urn:nrel_example/nrel00001041"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000862"
+ "@value": "nrel00000815"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000787",
+ "@id": "urn:nrel_example/nrel00000732",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000080"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000859"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000732"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000833",
+ "@type": [
+ "http://data.ashrae.org/standard223#Sensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "urn:nrel_example/nrel00000074"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ {
+ "@id": "urn:nrel_example/nrel00001027"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00000319"
+ "@id": "urn:nrel_example/nrel00000206"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000787"
+ "@value": "nrel00000833"
}
]
},
@@ -23015,164 +23261,161 @@
]
},
{
- "@id": "urn:nrel_example/nrel00001261",
+ "@id": "urn:nrel_example/nrel00000466",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@value": "nrel00000466"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001160",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ {
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001261"
+ "@value": "nrel00001160"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000581",
+ "@id": "urn:nrel_example/nrel00000969",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000223"
- },
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "urn:nrel_example/nrel00000320"
+ "@id": "urn:nrel_example/nrel00000736"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000403"
+ "@id": "urn:nrel_example/nrel00000054"
},
{
- "@id": "urn:nrel_example/nrel00000850"
+ "@id": "urn:nrel_example/nrel00000610"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000581"
+ "@value": "nrel00000969"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000782",
+ "@id": "urn:nrel_example/nrel00000791",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000148"
- },
- {
- "@id": "urn:nrel_example/nrel00000647"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001037"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000190"
- },
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000722"
- },
+ "@value": "nrel00000791"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000502",
+ "@type": [
+ "http://data.ashrae.org/standard223#Duct"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00001046"
+ "@id": "urn:nrel_example/nrel00000846"
},
{
- "@id": "urn:nrel_example/nrel00001052"
+ "@id": "urn:nrel_example/nrel00000948"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000820"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001067"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000782"
+ "@value": "nrel00000502"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000591",
+ "@id": "urn:nrel_example/nrel00000690",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000039"
- },
- {
- "@id": "urn:nrel_example/nrel00000416"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000604"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
}
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000200"
- },
- {
- "@id": "urn:nrel_example/nrel00000306"
- },
- {
- "@id": "urn:nrel_example/nrel00001136"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001226"
+ "@id": "http://qudt.org/vocab/unit/KiloW"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000933"
- },
+ "@value": "nrel00000690"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001244",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00001255"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000591"
+ "@value": "nrel00001244"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000544",
+ "@id": "urn:nrel_example/nrel00000096",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000544"
+ "@value": "nrel00000096"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001265",
+ "@id": "urn:nrel_example/nrel00000380",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -23183,452 +23426,435 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001265"
+ "@value": "nrel00000380"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000394",
+ "@id": "urn:nrel_example/nrel00000751",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:nrel_example/nrel00000138"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:nrel_example/nrel00000241"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00001283"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000394"
+ "@value": "nrel00000751"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000713",
+ "@id": "urn:nrel_example/nrel00000376",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Energy"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW-HR"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000713"
+ "@value": "nrel00000376"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001284",
+ "@id": "urn:nrel_example/nrel00000807",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000045"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001157"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000961"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001284"
+ "@value": "nrel00000807"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000201",
+ "@id": "urn:nrel_example/nrel00000864",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000201"
+ "@value": "nrel00000864"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000992",
+ "@id": "urn:nrel_example/nrel00000027",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000211"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000034"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000992"
+ "@value": "nrel00000027"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000839",
+ "@id": "urn:nrel_example/nrel00000658",
"@type": [
- "http://data.ashrae.org/standard223#CoolingCoil"
- ],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00001092"
- },
- {
- "@id": "urn:nrel_example/nrel00001115"
- }
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000356"
- },
- {
- "@id": "urn:nrel_example/nrel00000508"
- },
- {
- "@id": "urn:nrel_example/nrel00001062"
- },
- {
- "@id": "urn:nrel_example/nrel00001189"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000125"
- },
- {
- "@id": "urn:nrel_example/nrel00000552"
- },
- {
- "@id": "urn:nrel_example/nrel00000654"
- },
- {
- "@id": "urn:nrel_example/nrel00001126"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001247"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000839"
+ "@value": "nrel00000658"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000317",
+ "@id": "urn:nrel_example/nrel00000667",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000207"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000443"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000317"
+ "@value": "nrel00000667"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001126",
+ "@id": "urn:nrel_example/nrel00000519",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/A"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001126"
+ "@value": "nrel00000519"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000630",
+ "@id": "urn:nrel_example/nrel00000848",
"@type": [
"http://data.ashrae.org/standard223#CoolingCoil"
],
"http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:nrel_example/nrel00000707"
+ "@id": "urn:nrel_example/nrel00000581"
},
{
- "@id": "urn:nrel_example/nrel00001195"
+ "@id": "urn:nrel_example/nrel00000754"
}
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000353"
+ "@id": "urn:nrel_example/nrel00000146"
},
{
- "@id": "urn:nrel_example/nrel00000390"
+ "@id": "urn:nrel_example/nrel00000570"
},
{
- "@id": "urn:nrel_example/nrel00001122"
+ "@id": "urn:nrel_example/nrel00001013"
},
{
- "@id": "urn:nrel_example/nrel00001328"
+ "@id": "urn:nrel_example/nrel00001323"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000303"
+ "@id": "urn:nrel_example/nrel00000511"
},
{
- "@id": "urn:nrel_example/nrel00000333"
+ "@id": "urn:nrel_example/nrel00000727"
},
{
- "@id": "urn:nrel_example/nrel00000534"
+ "@id": "urn:nrel_example/nrel00000774"
},
{
- "@id": "urn:nrel_example/nrel00000993"
+ "@id": "urn:nrel_example/nrel00001184"
},
{
- "@id": "urn:nrel_example/nrel00001145"
+ "@id": "urn:nrel_example/nrel00001287"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000630"
+ "@value": "nrel00000848"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000806",
+ "@id": "urn:nrel_example/nrel00000143",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000806"
+ "@value": "nrel00000143"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001044",
+ "@id": "urn:nrel_example/nrel00001237",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000364"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000553"
+ "@value": "nrel00001237"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001005",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000555"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/KiloW"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001044"
+ "@value": "nrel00001005"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000413",
+ "@id": "urn:nrel_example/nrel00001172",
"@type": [
- "http://data.ashrae.org/standard223#Damper"
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000927"
- },
- {
- "@id": "urn:nrel_example/nrel00000950"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000013"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000103"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000413"
+ "@value": "nrel00001172"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000572",
+ "@id": "urn:nrel_example/nrel00001131",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "urn:nrel_example/nrel00000941"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ {
+ "@id": "urn:nrel_example/nrel00000121"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000681"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000572"
+ "@value": "nrel00001131"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000866",
+ "@id": "urn:nrel_example/nrel00000008",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000866"
+ "@value": "nrel00000008"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000038",
+ "@id": "urn:nrel_example/nrel00000862",
"@type": [
- "http://data.ashrae.org/standard223#FanCoilUnit"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000495"
- },
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000780"
+ "@id": "urn:nrel_example/nrel00000219"
},
{
- "@id": "urn:nrel_example/nrel00001187"
+ "@id": "urn:nrel_example/nrel00000792"
}
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000420"
- },
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:nrel_example/nrel00001270"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000173"
+ "@id": "urn:nrel_example/nrel00000417"
},
{
- "@id": "urn:nrel_example/nrel00000212"
- },
+ "@id": "urn:nrel_example/nrel00001134"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000228"
- },
+ "@value": "nrel00000862"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001042",
+ "@type": [
+ "http://data.ashrae.org/standard223#Valve"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000329"
+ "@id": "urn:nrel_example/nrel00000530"
},
{
- "@id": "urn:nrel_example/nrel00000884"
+ "@id": "urn:nrel_example/nrel00000834"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Cooling"
+ "@id": "urn:nrel_example/nrel00000606"
},
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "urn:nrel_example/nrel00001124"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000038"
+ "@value": "nrel00001042"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001022",
+ "@id": "urn:nrel_example/nrel00000817",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:nrel_example/nrel00001072"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:nrel_example/nrel00000684"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001022"
+ "@value": "nrel00000817"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000085",
+ "@id": "urn:nrel_example/nrel00000489",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
- {
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000085"
+ "@value": "nrel00000489"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000863",
+ "@id": "urn:nrel_example/nrel00001017",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
@@ -23639,14 +23865,22 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000863"
+ "@value": "nrel00001017"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000420",
+ "@id": "urn:nrel_example/nrel00000642",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Duct"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:nrel_example/nrel00000586"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000923"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -23655,293 +23889,294 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000420"
+ "@value": "nrel00000642"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000263",
+ "@id": "urn:nrel_example/nrel00001095",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:nrel_example/nrel00000668"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:nrel_example/nrel00000046"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000263"
+ "@value": "nrel00001095"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000466",
+ "@id": "urn:nrel_example/nrel00000319",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000466"
+ "@value": "nrel00000319"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001189",
+ "@id": "urn:nrel_example/nrel00000526",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001189"
+ "@value": "nrel00000526"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000217",
+ "@id": "urn:nrel_example/nrel00000591",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#HeatingCoil"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:nrel_example/nrel00000161"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
+ "@id": "urn:nrel_example/nrel00000039"
+ },
{
- "@id": "urn:nrel_example/nrel00000565"
+ "@id": "urn:nrel_example/nrel00000416"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000604"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@value": "nrel00000217"
+ "@id": "urn:nrel_example/nrel00000200"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000306"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001136"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001226"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000679",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00000933"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001255"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000679"
+ "@value": "nrel00000591"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000775",
+ "@id": "urn:nrel_example/nrel00001234",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000775"
+ "@value": "nrel00001234"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000849",
+ "@id": "urn:nrel_example/nrel00000197",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000948"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000048"
+ "@id": "http://qudt.org/vocab/unit/A"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000849"
+ "@value": "nrel00000197"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000708",
+ "@id": "urn:nrel_example/nrel00000914",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
- ],
- "http://data.ashrae.org/standard223#encloses": [
- {
- "@id": "urn:nrel_example/nrel00000939"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000345"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000866"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000708"
+ "@value": "nrel00000914"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000672",
+ "@id": "urn:nrel_example/nrel00000556",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000672"
+ "@value": "nrel00000556"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000858",
+ "@id": "urn:nrel_example/nrel00000151",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000858"
+ "@value": "nrel00000151"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000907",
+ "@id": "urn:nrel_example/nrel00000552",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000043"
- },
- {
- "@id": "urn:nrel_example/nrel00000790"
- },
- {
- "@id": "urn:nrel_example/nrel00001182"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001242"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000907"
+ "@value": "nrel00000552"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000645",
+ "@id": "urn:nrel_example/nrel00000398",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Energy"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW-HR"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000645"
+ "@value": "nrel00000398"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001047",
+ "@id": "urn:nrel_example/nrel00000388",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001047"
+ "@value": "nrel00000388"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000769",
+ "@id": "urn:nrel_example/nrel00000967",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000162"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000969"
+ "@value": "nrel00000967"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001240",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000054"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000769"
+ "@value": "nrel00001240"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000408",
+ "@id": "urn:nrel_example/nrel00000894",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -23952,265 +24187,276 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000408"
+ "@value": "nrel00000894"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001195",
+ "@id": "urn:nrel_example/nrel00001031",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000798"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000888"
+ "@id": "http://qudt.org/vocab/quantitykind/Energy"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000910"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001227"
+ "@id": "http://qudt.org/vocab/unit/KiloW-HR"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001195"
+ "@value": "nrel00001031"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000677",
+ "@id": "urn:nrel_example/nrel00000243",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000208"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000677"
+ "@value": "nrel00000243"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000810",
+ "@id": "urn:nrel_example/nrel00000023",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000810"
+ "@value": "nrel00000023"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000167",
+ "@id": "urn:nrel_example/nrel00001119",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Fan"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000703"
+ },
{
- "@value": "nrel00000167"
+ "@id": "urn:nrel_example/nrel00001078"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000640",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000406"
+ },
{
- "@value": "nrel00000640"
+ "@id": "urn:nrel_example/nrel00001077"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000867",
- "@type": [
- "http://data.ashrae.org/standard223#Zone"
],
- "http://data.ashrae.org/standard223#hasDomainSpace": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000080"
+ "@id": "urn:nrel_example/nrel00000072"
},
{
- "@id": "urn:nrel_example/nrel00000122"
+ "@id": "urn:nrel_example/nrel00000116"
},
{
- "@id": "urn:nrel_example/nrel00000587"
+ "@id": "urn:nrel_example/nrel00000126"
},
{
- "@id": "urn:nrel_example/nrel00000600"
+ "@id": "urn:nrel_example/nrel00000164"
},
{
- "@id": "urn:nrel_example/nrel00000631"
+ "@id": "urn:nrel_example/nrel00000272"
},
{
- "@id": "urn:nrel_example/nrel00000736"
+ "@id": "urn:nrel_example/nrel00000401"
},
{
- "@id": "urn:nrel_example/nrel00000862"
+ "@id": "urn:nrel_example/nrel00000558"
},
{
- "@id": "urn:nrel_example/nrel00001125"
+ "@id": "urn:nrel_example/nrel00000616"
},
{
- "@id": "urn:nrel_example/nrel00001197"
+ "@id": "urn:nrel_example/nrel00000670"
},
{
- "@id": "urn:nrel_example/nrel00001267"
+ "@id": "urn:nrel_example/nrel00000935"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001127"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000867"
+ "@value": "nrel00001119"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001232",
+ "@id": "urn:nrel_example/nrel00000211",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000309"
- },
- {
- "@id": "urn:nrel_example/nrel00000602"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001303"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000000"
- },
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000032"
- },
+ "@value": "nrel00000211"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001111",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000465"
- },
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00001284"
+ "@value": "nrel00001111"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000332",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000358"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001220"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001232"
+ "@value": "nrel00000332"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000702",
+ "@id": "urn:nrel_example/nrel00000908",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "urn:nrel_example/nrel00000397"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000702"
+ "@value": "nrel00000908"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000297",
+ "@id": "urn:nrel_example/nrel00000767",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000297"
+ "@value": "nrel00000767"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000318",
+ "@id": "urn:nrel_example/nrel00000213",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000318"
+ "@value": "nrel00000213"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000910",
+ "@id": "urn:nrel_example/nrel00000083",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00000437"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001104"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00001026"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001252"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000910"
+ "@value": "nrel00000083"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000158",
+ "@id": "urn:nrel_example/nrel00000691",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000891"
+ "@id": "urn:nrel_example/nrel00000535"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -24220,237 +24466,223 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000158"
+ "@value": "nrel00000691"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000936",
+ "@id": "urn:nrel_example/nrel00000811",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Frequency"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/HZ"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000936"
+ "@value": "nrel00000811"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000562",
+ "@id": "urn:nrel_example/nrel00000005",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000562"
+ "@value": "nrel00000005"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001120",
+ "@id": "urn:nrel_example/nrel00000367",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
+ "@id": "urn:nrel_example/nrel00000219"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "urn:nrel_example/nrel00000464"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000956"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001120"
+ "@value": "nrel00000367"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000982",
+ "@id": "urn:nrel_example/nrel00000777",
"@type": [
- "http://data.ashrae.org/standard223#AirHandlingUnit"
+ "http://data.ashrae.org/standard223#Fan"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000007"
- },
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000053"
+ "@id": "urn:nrel_example/nrel00000776"
},
{
- "@id": "urn:nrel_example/nrel00000061"
- },
+ "@id": "urn:nrel_example/nrel00001164"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000254"
+ "@id": "urn:nrel_example/nrel00000159"
},
{
- "@id": "urn:nrel_example/nrel00000446"
+ "@id": "urn:nrel_example/nrel00000185"
},
{
- "@id": "urn:nrel_example/nrel00000447"
+ "@id": "urn:nrel_example/nrel00000379"
},
{
- "@id": "urn:nrel_example/nrel00000683"
+ "@id": "urn:nrel_example/nrel00000450"
},
{
- "@id": "urn:nrel_example/nrel00000992"
+ "@id": "urn:nrel_example/nrel00000563"
},
{
- "@id": "urn:nrel_example/nrel00001087"
- }
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "@id": "urn:nrel_example/nrel00000662"
+ },
{
- "@id": "urn:nrel_example/nrel00000078"
+ "@id": "urn:nrel_example/nrel00000761"
},
{
- "@id": "urn:nrel_example/nrel00000211"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "@id": "urn:nrel_example/nrel00000778"
+ },
{
- "@id": "urn:nrel_example/nrel00000034"
+ "@id": "urn:nrel_example/nrel00000889"
},
{
- "@id": "urn:nrel_example/nrel00001070"
+ "@id": "urn:nrel_example/nrel00000974"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001290"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000982"
+ "@value": "nrel00000777"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000030",
+ "@id": "urn:nrel_example/nrel00000119",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000030"
+ "@value": "nrel00000119"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000515",
+ "@id": "urn:nrel_example/nrel00000960",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000745"
- }
+ "http://data.ashrae.org/standard223#TerminalUnit"
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:nrel_example/nrel00000160"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
+ "@id": "urn:nrel_example/nrel00000192"
+ },
{
- "@id": "urn:nrel_example/nrel00001286"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000494"
+ },
{
- "@value": "nrel00000515"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00001268",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:nrel_example/nrel00000531"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000747"
+ },
{
- "@value": "nrel00001268"
+ "@id": "urn:nrel_example/nrel00001008"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00001156",
- "@type": [
- "http://data.ashrae.org/standard223#Valve"
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000198"
+ "@id": "urn:nrel_example/nrel00000635"
},
{
- "@id": "urn:nrel_example/nrel00000578"
+ "@id": "urn:nrel_example/nrel00001023"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000788"
+ "@id": "urn:nrel_example/nrel00000081"
},
{
- "@id": "urn:nrel_example/nrel00001006"
+ "@id": "urn:nrel_example/nrel00000710"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001138"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001156"
+ "@value": "nrel00000960"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000670",
+ "@id": "urn:nrel_example/nrel00000611",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
+ "@id": "urn:nrel_example/nrel00000590"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "http://qudt.org/vocab/unit/A"
+ "@id": "urn:nrel_example/nrel00001121"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000009"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000670"
+ "@value": "nrel00000611"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000957",
+ "@id": "urn:nrel_example/nrel00000913",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -24461,447 +24693,459 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000957"
+ "@value": "nrel00000913"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001078",
+ "@id": "urn:nrel_example/nrel00000443",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001077"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000272"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001078"
+ "@value": "nrel00000443"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000789",
+ "@id": "urn:nrel_example/nrel00000179",
"@type": [
- "http://data.ashrae.org/standard223#FanCoilUnit"
+ "http://data.ashrae.org/standard223#Pump"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000361"
- },
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000381"
+ "@id": "urn:nrel_example/nrel00000178"
},
{
- "@id": "urn:nrel_example/nrel00000770"
+ "@id": "urn:nrel_example/nrel00000264"
}
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00001025"
+ "@id": "urn:nrel_example/nrel00000041"
},
{
- "@id": "urn:nrel_example/nrel00001301"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "@id": "urn:nrel_example/nrel00000097"
+ },
{
- "@id": "urn:nrel_example/nrel00000442"
+ "@id": "urn:nrel_example/nrel00000445"
},
{
- "@id": "urn:nrel_example/nrel00000481"
+ "@id": "urn:nrel_example/nrel00000646"
},
{
- "@id": "urn:nrel_example/nrel00000918"
+ "@id": "urn:nrel_example/nrel00000696"
},
{
- "@id": "urn:nrel_example/nrel00001238"
+ "@id": "urn:nrel_example/nrel00000860"
},
{
- "@id": "urn:nrel_example/nrel00001324"
- }
- ],
- "http://data.ashrae.org/standard223#hasRole": [
+ "@id": "urn:nrel_example/nrel00000990"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Role-Cooling"
+ "@id": "urn:nrel_example/nrel00001031"
},
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "urn:nrel_example/nrel00001191"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001230"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000789"
+ "@value": "nrel00000179"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000326",
+ "@id": "urn:nrel_example/nrel00000911",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00000869"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001183"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000326"
+ "@value": "nrel00000911"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000896",
+ "@id": "urn:nrel_example/nrel00000619",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001049"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000114"
+ "@value": "nrel00000619"
}
+ ]
+ },
+ {
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus",
+ "@type": [
+ "http://data.ashrae.org/standard223#Class",
+ "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus",
+ "http://www.w3.org/ns/shacl#NodeShape"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000594"
+ "@value": "EnumerationKind AlarmStatus"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://www.w3.org/2000/01/rdf-schema#subClassOf": [
{
- "@value": "nrel00000896"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000983",
+ "@id": "urn:nrel_example/nrel00000944",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000983"
+ "@value": "nrel00000944"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000736",
+ "@id": "urn:nrel_example/nrel00000060",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000045"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000162"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
- {
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00001014"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001295"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000736"
+ "@value": "nrel00000060"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000120",
+ "@id": "urn:nrel_example/nrel00000845",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000120"
+ "@value": "nrel00000845"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001023",
+ "@id": "urn:nrel_example/nrel00001228",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:nrel_example/nrel00000227"
+ }
+ ],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001023"
+ "@value": "nrel00001228"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000079",
+ "@id": "urn:nrel_example/nrel00001109",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000079"
+ "@value": "nrel00001109"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000300",
+ "@id": "urn:nrel_example/nrel00000064",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001050"
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000518"
+ "@id": "http://qudt.org/vocab/unit/IN_H2O"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000300"
+ "@value": "nrel00000064"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000546",
+ "@id": "urn:nrel_example/nrel00000461",
"@type": [
- "http://data.ashrae.org/standard223#Equipment"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@value": "nrel00000546"
+ "@id": "urn:nrel_example/nrel00001198"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000063",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000063"
+ "@value": "nrel00000461"
}
]
},
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus",
+ "@id": "urn:nrel_example/nrel00000159",
"@type": [
- "http://data.ashrae.org/standard223#Class",
- "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus",
- "http://www.w3.org/ns/shacl#NodeShape"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@value": "EnumerationKind AlarmStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/Energy"
}
],
- "http://www.w3.org/2000/01/rdf-schema#subClassOf": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind"
+ "@id": "http://qudt.org/vocab/unit/KiloW-HR"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000159"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000652",
+ "@id": "urn:nrel_example/nrel00000174",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00001197"
- }
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001121"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000499"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000652"
+ "@value": "nrel00000174"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001027",
+ "@id": "urn:nrel_example/nrel00000164",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000122"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000206"
- },
+ "@value": "nrel00000164"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000360",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000537"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001027"
+ "@value": "nrel00000360"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001028",
+ "@id": "urn:nrel_example/nrel00000074",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001028"
+ "@value": "nrel00000074"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000359",
+ "@id": "urn:nrel_example/nrel00000163",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/A"
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000359"
+ "@value": "nrel00000163"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000176",
+ "@id": "urn:nrel_example/nrel00000224",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000176"
+ "@value": "nrel00000224"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000557",
+ "@id": "urn:nrel_example/nrel00001223",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:nrel_example/nrel00000786"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001149"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:nrel_example/nrel00000363"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000489"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000557"
+ "@value": "nrel00001223"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001151",
+ "@id": "urn:nrel_example/nrel00000244",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-FlowStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001151"
+ "@value": "nrel00000244"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000301",
+ "@id": "urn:nrel_example/nrel00001251",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
@@ -24912,204 +25156,170 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000301"
+ "@value": "nrel00001251"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000865",
+ "@id": "urn:nrel_example/nrel00001148",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/IN_H2O"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000865"
+ "@value": "nrel00001148"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001198",
+ "@id": "urn:nrel_example/nrel00001069",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000461"
- },
- {
- "@id": "urn:nrel_example/nrel00001166"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001198"
+ "@value": "nrel00001069"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000010",
+ "@id": "urn:nrel_example/nrel00001120",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000818"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
}
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000336"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
- {
- "@id": "urn:nrel_example/nrel00000739"
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000010"
+ "@value": "nrel00001120"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000851",
+ "@id": "urn:nrel_example/nrel00001210",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000851"
+ "@value": "nrel00001210"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000090",
+ "@id": "urn:nrel_example/nrel00000307",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000466"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00001121"
+ "@id": "urn:nrel_example/nrel00000517"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000068"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000090"
+ "@value": "nrel00000307"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000786",
+ "@id": "urn:nrel_example/nrel00001033",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:nrel_example/nrel00001123"
+ }
+ ],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000786"
+ "@value": "nrel00001033"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001075",
+ "@id": "urn:nrel_example/nrel00000865",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/A"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00001075"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000302",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/IN_H2O"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000302"
+ "@value": "nrel00000865"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001256",
+ "@id": "urn:nrel_example/nrel00001150",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000678"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/A"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001256"
+ "@value": "nrel00001150"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000298",
+ "@id": "urn:nrel_example/nrel00000202",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -25125,14 +25335,14 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000298"
+ "@value": "nrel00000202"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000087",
+ "@id": "urn:nrel_example/nrel00000178",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -25141,12 +25351,12 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000087"
+ "@value": "nrel00000178"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000809",
+ "@id": "urn:nrel_example/nrel00000498",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -25162,346 +25372,284 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000809"
+ "@value": "nrel00000498"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000116",
+ "@id": "urn:nrel_example/nrel00000693",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Energy"
+ "@id": "urn:nrel_example/nrel00001194"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW-HR"
+ "@id": "urn:nrel_example/nrel00000373"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000116"
+ "@value": "nrel00000693"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000147",
+ "@id": "urn:nrel_example/nrel00000618",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:nrel_example/nrel00000517"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000147"
+ "@value": "nrel00000618"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001246",
+ "@id": "urn:nrel_example/nrel00000195",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Energy"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW-HR"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001246"
+ "@value": "nrel00000195"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000183",
+ "@id": "urn:nrel_example/nrel00001127",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/Frequency"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/HZ"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000183"
+ "@value": "nrel00001127"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000819",
+ "@id": "urn:nrel_example/nrel00000966",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00000059"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000098"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000658"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@value": "nrel00000819"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00001251",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00000109"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000845"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001251"
+ "@value": "nrel00000966"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001254",
+ "@id": "urn:nrel_example/nrel00000175",
"@type": [
- "http://data.ashrae.org/standard223#TerminalUnit"
- ],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000342"
- },
- {
- "@id": "urn:nrel_example/nrel00000524"
- },
- {
- "@id": "urn:nrel_example/nrel00000686"
- },
- {
- "@id": "urn:nrel_example/nrel00000782"
- },
- {
- "@id": "urn:nrel_example/nrel00001231"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000688"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000967"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000176"
- },
- {
- "@id": "urn:nrel_example/nrel00000865"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001221"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001254"
+ "@value": "nrel00000175"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000656",
+ "@id": "urn:nrel_example/nrel00001318",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000736"
+ "@id": "urn:nrel_example/nrel00000122"
}
],
"http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "urn:nrel_example/nrel00000969"
+ "@id": "urn:nrel_example/nrel00001027"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00001295"
+ "@id": "urn:nrel_example/nrel00000335"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000656"
+ "@value": "nrel00001318"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000365",
+ "@id": "urn:nrel_example/nrel00000283",
"@type": [
- "http://data.ashrae.org/standard223#FanCoilUnit"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000580"
- },
- {
- "@id": "urn:nrel_example/nrel00000630"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001174"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000001"
- },
- {
- "@id": "urn:nrel_example/nrel00000459"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000157"
- },
- {
- "@id": "urn:nrel_example/nrel00000425"
- },
- {
- "@id": "urn:nrel_example/nrel00000672"
- },
- {
- "@id": "urn:nrel_example/nrel00001109"
- },
- {
- "@id": "urn:nrel_example/nrel00001314"
- }
- ],
- "http://data.ashrae.org/standard223#hasRole": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Cooling"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000365"
+ "@value": "nrel00000283"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001301",
+ "@id": "urn:nrel_example/nrel00000874",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001301"
+ "@value": "nrel00000874"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000573",
+ "@id": "urn:nrel_example/nrel00000733",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000941"
- }
- ],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "@id": "urn:nrel_example/nrel00000949"
+ },
{
- "@id": "urn:nrel_example/nrel00000121"
+ "@id": "urn:nrel_example/nrel00001057"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000404"
+ "@id": "urn:nrel_example/nrel00000357"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001017"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000573"
+ "@value": "nrel00000733"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000166",
+ "@id": "urn:nrel_example/nrel00000900",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Frequency"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/HZ"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000166"
+ "@value": "nrel00000900"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000427",
+ "@id": "urn:nrel_example/nrel00000042",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@value": "nrel00000427"
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000526",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/IN_H2O"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000526"
+ "@value": "nrel00000042"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000779",
+ "@id": "urn:nrel_example/nrel00000467",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -25512,332 +25660,288 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000779"
+ "@value": "nrel00000467"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000076",
+ "@id": "urn:nrel_example/nrel00000585",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001047"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000076"
+ "@value": "nrel00000585"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000631",
+ "@id": "urn:nrel_example/nrel00000561",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#Valve"
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000138"
+ "@id": "urn:nrel_example/nrel00000448"
},
{
- "@id": "urn:nrel_example/nrel00001200"
- }
- ],
- "http://data.ashrae.org/standard223#hasDomain": [
- {
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "urn:nrel_example/nrel00000921"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000665"
+ "@id": "urn:nrel_example/nrel00000106"
},
{
- "@id": "urn:nrel_example/nrel00001085"
+ "@id": "urn:nrel_example/nrel00001054"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000631"
+ "@value": "nrel00000561"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000735",
+ "@id": "urn:nrel_example/nrel00000132",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000735"
+ "@value": "nrel00000132"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000703",
+ "@id": "urn:nrel_example/nrel00001261",
"@type": [
- "http://data.ashrae.org/standard223#Damper"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000215"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001108"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000698"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001188"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000703"
+ "@value": "nrel00001261"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000941",
+ "@id": "urn:nrel_example/nrel00000731",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000251"
+ "@id": "urn:nrel_example/nrel00000640"
},
{
- "@id": "urn:nrel_example/nrel00000846"
- }
- ],
- "http://data.ashrae.org/standard223#hasDomain": [
- {
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "urn:nrel_example/nrel00001270"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000404"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000681"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000941"
+ "@value": "nrel00000731"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000100",
+ "@id": "urn:nrel_example/nrel00000105",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@value": "nrel00000100"
+ "@id": "http://qudt.org/vocab/quantitykind/Frequency"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00001193",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/HZ"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001193"
+ "@value": "nrel00000105"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000939",
+ "@id": "urn:nrel_example/nrel00000543",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000281"
- },
- {
- "@id": "urn:nrel_example/nrel00000474"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000308"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001090"
+ "@id": "http://qudt.org/vocab/unit/KiloW"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000939"
+ "@value": "nrel00000543"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000078",
+ "@id": "urn:nrel_example/nrel00000979",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000078"
+ "@value": "nrel00000979"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001219",
+ "@id": "urn:nrel_example/nrel00000765",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000462"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000924"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001219"
+ "@value": "nrel00000765"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000410",
+ "@id": "urn:nrel_example/nrel00000104",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000410"
+ "@value": "nrel00000104"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000915",
+ "@id": "urn:nrel_example/nrel00001245",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000915"
+ "@value": "nrel00001245"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000002",
+ "@id": "urn:nrel_example/nrel00000384",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ "@id": "http://qudt.org/vocab/quantitykind/Frequency"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "http://qudt.org/vocab/unit/HZ"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000002"
+ "@value": "nrel00000384"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000511",
+ "@id": "urn:nrel_example/nrel00001316",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000511"
+ "@value": "nrel00001316"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000642",
+ "@id": "urn:nrel_example/nrel00000875",
"@type": [
"http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000586"
+ "@id": "urn:nrel_example/nrel00000107"
},
{
- "@id": "urn:nrel_example/nrel00000923"
+ "@id": "urn:nrel_example/nrel00000899"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -25847,49 +25951,28 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000642"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000129",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Energy"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
- {
- "@id": "http://qudt.org/vocab/unit/KiloW-HR"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00000129"
+ "@value": "nrel00000875"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000131",
+ "@id": "urn:nrel_example/nrel00001018",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000131"
+ "@value": "nrel00001018"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000368",
+ "@id": "urn:nrel_example/nrel00000511",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -25905,12 +25988,12 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000368"
+ "@value": "nrel00000511"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001147",
+ "@id": "urn:nrel_example/nrel00000910",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
@@ -25921,30 +26004,19 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001147"
+ "@value": "nrel00000910"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000026",
+ "@id": "urn:nrel_example/nrel00000424",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@value": "nrel00000026"
+ "@id": "urn:nrel_example/nrel00000077"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00001200",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -25953,452 +26025,390 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001200"
+ "@value": "nrel00000424"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000733",
+ "@id": "urn:nrel_example/nrel00001255",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000949"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001057"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000357"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001017"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000733"
+ "@value": "nrel00001255"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000323",
+ "@id": "urn:nrel_example/nrel00001085",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000631"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000241"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000665"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000323"
+ "@value": "nrel00001085"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001258",
+ "@id": "urn:nrel_example/nrel00001100",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
+ "http://data.ashrae.org/standard223#HeatExchanger"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:nrel_example/nrel00000120"
+ "@id": "urn:nrel_example/nrel00000449"
},
{
- "@id": "urn:nrel_example/nrel00000415"
+ "@id": "urn:nrel_example/nrel00001258"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001263"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000349"
+ "@id": "urn:nrel_example/nrel00000261"
},
{
- "@id": "urn:nrel_example/nrel00000644"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000554"
+ },
{
- "@value": "nrel00001258"
+ "@id": "urn:nrel_example/nrel00000577"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001180"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00001021",
- "@type": [
- "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000186"
+ "@id": "urn:nrel_example/nrel00000687"
},
{
- "@id": "urn:nrel_example/nrel00001301"
+ "@id": "urn:nrel_example/nrel00000885"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001179"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Role-Evaporator"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001021"
+ "@value": "nrel00001100"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000295",
+ "@id": "urn:nrel_example/nrel00001014",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Energy"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW-HR"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000295"
+ "@value": "nrel00001014"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000783",
+ "@id": "urn:nrel_example/nrel00001320",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000970"
- },
+ "@id": "urn:nrel_example/nrel00000792"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "urn:nrel_example/nrel00000984"
+ "@id": "urn:nrel_example/nrel00000464"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000825"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000783"
+ "@value": "nrel00001320"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000255",
+ "@id": "urn:nrel_example/nrel00000674",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000397"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000255"
+ "@value": "nrel00000674"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001119",
+ "@id": "urn:nrel_example/nrel00000240",
"@type": [
- "http://data.ashrae.org/standard223#Fan"
- ],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000703"
- },
- {
- "@id": "urn:nrel_example/nrel00001078"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000406"
- },
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00001077"
+ "@id": "urn:nrel_example/nrel00000589"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000072"
- },
- {
- "@id": "urn:nrel_example/nrel00000116"
- },
- {
- "@id": "urn:nrel_example/nrel00000126"
- },
- {
- "@id": "urn:nrel_example/nrel00000164"
- },
- {
- "@id": "urn:nrel_example/nrel00000272"
- },
- {
- "@id": "urn:nrel_example/nrel00000401"
- },
- {
- "@id": "urn:nrel_example/nrel00000558"
- },
- {
- "@id": "urn:nrel_example/nrel00000616"
- },
- {
- "@id": "urn:nrel_example/nrel00000670"
- },
- {
- "@id": "urn:nrel_example/nrel00000935"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001127"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001119"
+ "@value": "nrel00000240"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000767",
+ "@id": "urn:nrel_example/nrel00000980",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@value": "nrel00000767"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000548",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000548"
+ "@value": "nrel00000980"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001289",
+ "@id": "urn:nrel_example/nrel00000129",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
+ "@id": "http://qudt.org/vocab/quantitykind/Energy"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/A"
+ "@id": "http://qudt.org/vocab/unit/KiloW-HR"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001289"
+ "@value": "nrel00000129"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000455",
+ "@id": "urn:nrel_example/nrel00000879",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Frequency"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/HZ"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000455"
+ "@value": "nrel00000879"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001276",
+ "@id": "urn:nrel_example/nrel00000867",
"@type": [
- "http://data.ashrae.org/standard223#FanCoilUnit"
+ "http://data.ashrae.org/standard223#Zone"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#hasDomainSpace": [
{
- "@id": "urn:nrel_example/nrel00000757"
+ "@id": "urn:nrel_example/nrel00000080"
},
{
- "@id": "urn:nrel_example/nrel00000777"
+ "@id": "urn:nrel_example/nrel00000122"
},
{
- "@id": "urn:nrel_example/nrel00001142"
- }
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "@id": "urn:nrel_example/nrel00000587"
+ },
{
- "@id": "urn:nrel_example/nrel00000100"
+ "@id": "urn:nrel_example/nrel00000600"
},
{
- "@id": "urn:nrel_example/nrel00000873"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "@id": "urn:nrel_example/nrel00000631"
+ },
{
- "@id": "urn:nrel_example/nrel00000141"
+ "@id": "urn:nrel_example/nrel00000736"
},
{
- "@id": "urn:nrel_example/nrel00000382"
+ "@id": "urn:nrel_example/nrel00000862"
},
{
- "@id": "urn:nrel_example/nrel00000711"
+ "@id": "urn:nrel_example/nrel00001125"
},
{
- "@id": "urn:nrel_example/nrel00000765"
+ "@id": "urn:nrel_example/nrel00001197"
},
{
- "@id": "urn:nrel_example/nrel00000959"
+ "@id": "urn:nrel_example/nrel00001267"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Cooling"
+ "@value": "nrel00000867"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000989",
+ "@type": [
+ "http://data.ashrae.org/standard223#Zone"
+ ],
+ "http://data.ashrae.org/standard223#hasDomainSpace": [
+ {
+ "@id": "urn:nrel_example/nrel00000649"
},
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "urn:nrel_example/nrel00000818"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000939"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000941"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001276"
+ "@value": "nrel00000989"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000142",
+ "@id": "urn:nrel_example/nrel00000015",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000948"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000641"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000142"
+ "@value": "nrel00000015"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000750",
+ "@id": "urn:nrel_example/nrel00000406",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ "@id": "urn:nrel_example/nrel00001211"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000750"
+ "@value": "nrel00000406"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001236",
+ "@id": "urn:nrel_example/nrel00000052",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001236"
+ "@value": "nrel00000052"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001122",
+ "@id": "urn:nrel_example/nrel00001055",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Energy"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/KiloW-HR"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001122"
+ "@value": "nrel00001055"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000407",
+ "@id": "urn:nrel_example/nrel00000504",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -26409,18 +26419,18 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000407"
+ "@value": "nrel00000504"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000691",
+ "@id": "urn:nrel_example/nrel00001166",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000535"
+ "@id": "urn:nrel_example/nrel00001198"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -26430,430 +26440,471 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000691"
+ "@value": "nrel00001166"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000791",
+ "@id": "urn:nrel_example/nrel00001274",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:nrel_example/nrel00000078"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000791"
+ "@value": "nrel00001274"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000969",
+ "@id": "urn:nrel_example/nrel00000321",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000736"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000054"
- },
+ "@value": "nrel00000321"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000855",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000610"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000969"
+ "@value": "nrel00000855"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000405",
+ "@id": "urn:nrel_example/nrel00000273",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#HeatingCoil"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "urn:nrel_example/nrel00000214"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000293"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000920"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "urn:nrel_example/nrel00000040"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000638"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000720"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001069"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000412"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000419"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000405"
+ "@value": "nrel00000273"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000610",
+ "@id": "urn:nrel_example/nrel00000157",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000610"
+ "@value": "nrel00000157"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000451",
+ "@id": "urn:nrel_example/nrel00000091",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000451"
+ "@value": "nrel00000091"
}
]
},
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-FlowStatus",
+ "@id": "urn:nrel_example/nrel00000838",
"@type": [
- "http://data.ashrae.org/standard223#Class",
- "http://data.ashrae.org/standard223#EnumerationKind-FlowStatus",
- "http://www.w3.org/ns/shacl#NodeShape"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@value": "EnumerationKind FlowStatus"
+ "@id": "urn:nrel_example/nrel00000399"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000714"
}
],
- "http://www.w3.org/2000/01/rdf-schema#subClassOf": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000838"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000173",
+ "@id": "urn:nrel_example/nrel00000876",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000173"
+ "@value": "nrel00000876"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000497",
+ "@id": "urn:nrel_example/nrel00000652",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00001265"
+ "@id": "urn:nrel_example/nrel00001197"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ {
+ "@id": "urn:nrel_example/nrel00001121"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00000726"
+ "@id": "urn:nrel_example/nrel00000499"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000497"
+ "@value": "nrel00000652"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000144",
+ "@id": "urn:nrel_example/nrel00001248",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Energy"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW-HR"
+ "@value": "nrel00001248"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000620",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000144"
+ "@value": "nrel00000620"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001153",
+ "@id": "urn:nrel_example/nrel00000428",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001153"
+ "@value": "nrel00000428"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000588",
+ "@id": "urn:nrel_example/nrel00000423",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000588"
+ "@value": "nrel00000423"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000984",
+ "@id": "urn:nrel_example/nrel00000103",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000984"
+ "@value": "nrel00000103"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001116",
+ "@id": "urn:nrel_example/nrel00000829",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00001267"
+ "@id": "urn:nrel_example/nrel00000600"
}
],
"http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "urn:nrel_example/nrel00001165"
+ "@id": "urn:nrel_example/nrel00000114"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00000184"
+ "@id": "urn:nrel_example/nrel00000847"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001116"
+ "@value": "nrel00000829"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001083",
+ "@id": "urn:nrel_example/nrel00000897",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Energy"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW-HR"
+ "@value": "nrel00000897"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000032",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001083"
+ "@value": "nrel00000032"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001034",
+ "@id": "urn:nrel_example/nrel00000302",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001034"
+ "@value": "nrel00000302"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000824",
+ "@id": "urn:nrel_example/nrel00000661",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000386"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000532"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000410"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001248"
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000824"
+ "@value": "nrel00000661"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001176",
+ "@id": "urn:nrel_example/nrel00000034",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000137"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000561"
- },
- {
- "@id": "urn:nrel_example/nrel00001095"
- }
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000625"
- },
- {
- "@id": "urn:nrel_example/nrel00000668"
- },
- {
- "@id": "urn:nrel_example/nrel00000810"
- },
- {
- "@id": "urn:nrel_example/nrel00001102"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000046"
- },
- {
- "@id": "urn:nrel_example/nrel00000623"
+ "@id": "http://qudt.org/vocab/unit/IN_H2O"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001176"
+ "@value": "nrel00000034"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000220",
+ "@id": "urn:nrel_example/nrel00001187",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#HeatingCoil"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000733"
+ },
{
- "@value": "nrel00000220"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00001201",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "@id": "urn:nrel_example/nrel00001181"
+ },
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00001205"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@value": "nrel00001201"
+ "@id": "urn:nrel_example/nrel00000504"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000595"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000705"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000737"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000913",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:nrel_example/nrel00000263"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000915"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000913"
+ "@value": "nrel00001187"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000587",
+ "@id": "urn:nrel_example/nrel00000631",
"@type": [
"http://data.ashrae.org/standard223#DomainSpace"
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000745"
+ "@id": "urn:nrel_example/nrel00000138"
},
{
- "@id": "urn:nrel_example/nrel00000986"
+ "@id": "urn:nrel_example/nrel00001200"
}
],
"http://data.ashrae.org/standard223#hasDomain": [
@@ -26863,80 +26914,54 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000433"
+ "@id": "urn:nrel_example/nrel00000665"
},
{
- "@id": "urn:nrel_example/nrel00000844"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00000587"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000378",
- "@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000220"
- }
- ],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
- {
- "@id": "urn:nrel_example/nrel00000859"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
- {
- "@id": "urn:nrel_example/nrel00000284"
+ "@id": "urn:nrel_example/nrel00001085"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000378"
+ "@value": "nrel00000631"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000722",
+ "@id": "urn:nrel_example/nrel00000882",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000722"
+ "@value": "nrel00000882"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000888",
+ "@id": "urn:nrel_example/nrel00001301",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000888"
+ "@value": "nrel00001301"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000128",
+ "@id": "urn:nrel_example/nrel00000294",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -26950,133 +26975,140 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000128"
+ "@value": "nrel00000294"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000373",
+ "@id": "urn:nrel_example/nrel00000288",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/IN_H2O"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000373"
+ "@value": "nrel00000288"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000593",
+ "@id": "urn:nrel_example/nrel00000035",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
+ "http://data.ashrae.org/standard223#CoolingCoil"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:nrel_example/nrel00000087"
+ "@id": "urn:nrel_example/nrel00000522"
},
{
- "@id": "urn:nrel_example/nrel00000434"
+ "@id": "urn:nrel_example/nrel00000824"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000301"
+ "@id": "urn:nrel_example/nrel00000317"
},
{
- "@id": "urn:nrel_example/nrel00001215"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000685"
+ },
{
- "@value": "nrel00000593"
+ "@id": "urn:nrel_example/nrel00000808"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000976"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000485",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:nrel_example/nrel00000028"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000085"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000243"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000253"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000994"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000485"
+ "@value": "nrel00000035"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000543",
+ "@id": "urn:nrel_example/nrel00001219",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ "@id": "urn:nrel_example/nrel00000462"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000924"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000543"
+ "@value": "nrel00001219"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000872",
+ "@id": "urn:nrel_example/nrel00000902",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00001234"
+ "@id": "urn:nrel_example/nrel00000100"
},
{
- "@id": "urn:nrel_example/nrel00001298"
+ "@id": "urn:nrel_example/nrel00000775"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00001209"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001251"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000872"
+ "@value": "nrel00000902"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000995",
+ "@id": "urn:nrel_example/nrel00000088",
"@type": [
"http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000131"
+ "@id": "urn:nrel_example/nrel00000986"
},
{
- "@id": "urn:nrel_example/nrel00001259"
+ "@id": "urn:nrel_example/nrel00001194"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -27086,193 +27118,155 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000995"
+ "@value": "nrel00000088"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000192",
+ "@id": "urn:nrel_example/nrel00000917",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000971"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00001169"
+ "@id": "urn:nrel_example/nrel00000948"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00001060"
- },
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00001327"
+ "@id": "urn:nrel_example/nrel00000124"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000192"
+ "@value": "nrel00000917"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000887",
+ "@id": "urn:nrel_example/nrel00000267",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00001311"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000575"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000887"
+ "@value": "nrel00000267"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001101",
+ "@id": "urn:nrel_example/nrel00001295",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000806"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000864"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001101"
+ "@value": "nrel00001295"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001170",
+ "@id": "urn:nrel_example/nrel00000604",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00001136"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00001255"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001170"
+ "@value": "nrel00000604"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000203",
+ "@id": "urn:nrel_example/nrel00000632",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000203"
+ "@value": "nrel00000632"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001033",
+ "@id": "urn:nrel_example/nrel00000385",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00001123"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001033"
+ "@value": "nrel00000385"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000911",
+ "@id": "urn:nrel_example/nrel00000819",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000869"
- },
- {
- "@id": "urn:nrel_example/nrel00001183"
- }
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000911"
+ "@value": "nrel00000819"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001231",
+ "@id": "urn:nrel_example/nrel00000153",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000366"
- },
- {
- "@id": "urn:nrel_example/nrel00000655"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000695"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001271"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001231"
+ "@value": "nrel00000153"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000719",
+ "@id": "urn:nrel_example/nrel00000551",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -27288,28 +27282,12 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000719"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000428",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00000428"
+ "@value": "nrel00000551"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000796",
+ "@id": "urn:nrel_example/nrel00000877",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
@@ -27320,14 +27298,14 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000796"
+ "@value": "nrel00000877"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000981",
+ "@id": "urn:nrel_example/nrel00000928",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
@@ -27336,395 +27314,343 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000981"
+ "@value": "nrel00000928"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000355",
+ "@id": "urn:nrel_example/nrel00000576",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000355"
+ "@value": "nrel00000576"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000534",
+ "@id": "urn:nrel_example/nrel00000825",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000534"
+ "@value": "nrel00000825"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000925",
+ "@id": "urn:nrel_example/nrel00000563",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000441"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000118"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000925"
+ "@value": "nrel00000563"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000247",
+ "@id": "urn:nrel_example/nrel00000338",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00001105"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000859"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000987"
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000247"
+ "@value": "nrel00000338"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001052",
+ "@id": "urn:nrel_example/nrel00000827",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:nrel_example/nrel00000967"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001052"
+ "@value": "nrel00000827"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001247",
+ "@id": "urn:nrel_example/nrel00000903",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:nrel_example/nrel00000589"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001247"
+ "@value": "nrel00000903"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001322",
+ "@id": "urn:nrel_example/nrel00001303",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "urn:nrel_example/nrel00000622"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000682"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000286"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000679"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001322"
+ "@value": "nrel00001303"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000729",
+ "@id": "urn:nrel_example/nrel00000976",
"@type": [
- "http://data.ashrae.org/standard223#Fan"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000018"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000619"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000023"
- },
- {
- "@id": "urn:nrel_example/nrel00000060"
- },
- {
- "@id": "urn:nrel_example/nrel00000201"
- },
- {
- "@id": "urn:nrel_example/nrel00000232"
- },
- {
- "@id": "urn:nrel_example/nrel00000614"
- },
- {
- "@id": "urn:nrel_example/nrel00000843"
- },
- {
- "@id": "urn:nrel_example/nrel00000878"
- },
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000886"
- },
+ "@value": "nrel00000976"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000759",
+ "@type": [
+ "http://data.ashrae.org/standard223#Duct"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000926"
+ "@id": "urn:nrel_example/nrel00000025"
},
{
- "@id": "urn:nrel_example/nrel00001083"
- },
+ "@id": "urn:nrel_example/nrel00000040"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001146"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000729"
+ "@value": "nrel00000759"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001107",
+ "@id": "urn:nrel_example/nrel00000669",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/IN_H2O"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001107"
+ "@value": "nrel00000669"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000282",
+ "@id": "urn:nrel_example/nrel00000497",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000966"
+ "@id": "urn:nrel_example/nrel00001265"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000091"
- },
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00000113"
+ "@id": "urn:nrel_example/nrel00000726"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000282"
+ "@value": "nrel00000497"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000859",
+ "@id": "urn:nrel_example/nrel00000093",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000080"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000284"
- },
+ "@value": "nrel00000093"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001137",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000987"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000859"
+ "@value": "nrel00001137"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000338",
+ "@id": "urn:nrel_example/nrel00000821",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000338"
+ "@value": "nrel00000821"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000522",
+ "@id": "urn:nrel_example/nrel00000927",
"@type": [
- "http://data.ashrae.org/standard223#Pump"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000801"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000957"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000057"
- },
- {
- "@id": "urn:nrel_example/nrel00000144"
- },
- {
- "@id": "urn:nrel_example/nrel00000267"
- },
- {
- "@id": "urn:nrel_example/nrel00000341"
- },
- {
- "@id": "urn:nrel_example/nrel00000352"
- },
- {
- "@id": "urn:nrel_example/nrel00000507"
- },
- {
- "@id": "urn:nrel_example/nrel00000520"
- },
- {
- "@id": "urn:nrel_example/nrel00000900"
- },
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00001005"
- },
+ "@value": "nrel00000927"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000541",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001245"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000522"
+ "@value": "nrel00000541"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000870",
+ "@id": "urn:nrel_example/nrel00000963",
"@type": [
- "http://data.ashrae.org/standard223#Pump"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000901"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000975"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000177"
- },
- {
- "@id": "urn:nrel_example/nrel00000279"
- },
- {
- "@id": "urn:nrel_example/nrel00000547"
- },
- {
- "@id": "urn:nrel_example/nrel00000863"
- },
- {
- "@id": "urn:nrel_example/nrel00000972"
- },
- {
- "@id": "urn:nrel_example/nrel00001045"
- },
- {
- "@id": "urn:nrel_example/nrel00001053"
- },
- {
- "@id": "urn:nrel_example/nrel00001175"
- },
- {
- "@id": "urn:nrel_example/nrel00001253"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001310"
+ "@id": "http://qudt.org/vocab/unit/A"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000870"
+ "@value": "nrel00000963"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001007",
+ "@id": "urn:nrel_example/nrel00000441",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -27735,802 +27661,815 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001007"
+ "@value": "nrel00000441"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001188",
+ "@id": "urn:nrel_example/nrel00000610",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001188"
+ "@value": "nrel00000610"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000029",
+ "@id": "urn:nrel_example/nrel00000106",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Frequency"
- }
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/HZ"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000029"
+ "@value": "nrel00000106"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000777",
+ "@id": "urn:nrel_example/nrel00000311",
"@type": [
- "http://data.ashrae.org/standard223#Fan"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000776"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001164"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000159"
- },
- {
- "@id": "urn:nrel_example/nrel00000185"
- },
- {
- "@id": "urn:nrel_example/nrel00000379"
- },
- {
- "@id": "urn:nrel_example/nrel00000450"
- },
- {
- "@id": "urn:nrel_example/nrel00000563"
- },
- {
- "@id": "urn:nrel_example/nrel00000662"
- },
- {
- "@id": "urn:nrel_example/nrel00000761"
- },
- {
- "@id": "urn:nrel_example/nrel00000778"
- },
- {
- "@id": "urn:nrel_example/nrel00000889"
- },
- {
- "@id": "urn:nrel_example/nrel00000974"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001290"
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000777"
+ "@value": "nrel00000311"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000334",
+ "@id": "urn:nrel_example/nrel00001062",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000587"
- }
- ],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
- {
- "@id": "urn:nrel_example/nrel00000160"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000433"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000334"
+ "@value": "nrel00001062"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000817",
+ "@id": "urn:nrel_example/nrel00000188",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00001072"
+ "@id": "urn:nrel_example/nrel00000249"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000596"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000684"
+ "@id": "urn:nrel_example/nrel00000694"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000700"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000817"
+ "@value": "nrel00000188"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001210",
+ "@id": "urn:nrel_example/nrel00000067",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001210"
+ "@value": "nrel00000067"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000576",
+ "@id": "urn:nrel_example/nrel00000325",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000576"
+ "@value": "nrel00000325"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001143",
+ "@id": "urn:nrel_example/nrel00000789",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#FanCoilUnit"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:nrel_example/nrel00000512"
+ "@id": "urn:nrel_example/nrel00000361"
},
{
- "@id": "urn:nrel_example/nrel00001193"
+ "@id": "urn:nrel_example/nrel00000381"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000770"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00001025"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001301"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@value": "nrel00001143"
+ "@id": "urn:nrel_example/nrel00000442"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000481"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000918"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001238"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001324"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000177",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Role-Cooling"
+ },
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000177"
+ "@value": "nrel00000789"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000725",
+ "@id": "urn:nrel_example/nrel00000117",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000441"
- },
+ "@id": "urn:nrel_example/nrel00000966"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "urn:nrel_example/nrel00000590"
+ "@id": "urn:nrel_example/nrel00000282"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000845"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000725"
+ "@value": "nrel00000117"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000690",
+ "@id": "urn:nrel_example/nrel00000282",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ "@id": "urn:nrel_example/nrel00000966"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW"
+ "@id": "urn:nrel_example/nrel00000091"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000113"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000690"
+ "@value": "nrel00000282"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000294",
+ "@id": "urn:nrel_example/nrel00000641",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000294"
+ "@value": "nrel00000641"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000634",
+ "@id": "urn:nrel_example/nrel00000121",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00000941"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000071"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000576"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000634"
+ "@value": "nrel00000121"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000349",
+ "@id": "urn:nrel_example/nrel00000312",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00000869"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001228"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000047"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000196"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000349"
+ "@value": "nrel00000312"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000774",
+ "@id": "urn:nrel_example/nrel00000516",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000774"
+ "@value": "nrel00000516"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000159",
+ "@id": "urn:nrel_example/nrel00001068",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Energy"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW-HR"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000159"
+ "@value": "nrel00001068"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000457",
+ "@id": "urn:nrel_example/nrel00000816",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:nrel_example/nrel00001125"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:nrel_example/nrel00000500"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000002"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000457"
+ "@value": "nrel00000816"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000153",
+ "@id": "urn:nrel_example/nrel00000003",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#HeatingCoil"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:nrel_example/nrel00000804"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001038"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001156"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@value": "nrel00000153"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00001314",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "@id": "urn:nrel_example/nrel00000612"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000676"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000897"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000953"
+ }
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "urn:nrel_example/nrel00000203"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000895"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001314"
+ "@value": "nrel00000003"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000027",
+ "@id": "urn:nrel_example/nrel00001037",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:nrel_example/nrel00000722"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:nrel_example/nrel00000820"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000027"
+ "@value": "nrel00001037"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001223",
+ "@id": "urn:nrel_example/nrel00000934",
"@type": [
"http://data.ashrae.org/standard223#Valve"
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000786"
+ "@id": "urn:nrel_example/nrel00000153"
},
{
- "@id": "urn:nrel_example/nrel00001149"
+ "@id": "urn:nrel_example/nrel00000302"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000363"
+ "@id": "urn:nrel_example/nrel00000653"
},
{
- "@id": "urn:nrel_example/nrel00000489"
+ "@id": "urn:nrel_example/nrel00001249"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001223"
+ "@value": "nrel00000934"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000290",
+ "@id": "urn:nrel_example/nrel00001071",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:nrel_example/nrel00000748"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00001236"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000290"
+ "@value": "nrel00001071"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001046",
+ "@id": "urn:nrel_example/nrel00000173",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001046"
+ "@value": "nrel00000173"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000558",
+ "@id": "urn:nrel_example/nrel00000394",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000558"
+ "@value": "nrel00000394"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001108",
+ "@id": "urn:nrel_example/nrel00000434",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001108"
+ "@value": "nrel00000434"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000218",
+ "@id": "urn:nrel_example/nrel00001280",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Energy"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW-HR"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000218"
+ "@value": "nrel00001280"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001328",
+ "@id": "urn:nrel_example/nrel00000890",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/KiloW"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001328"
+ "@value": "nrel00000890"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000328",
+ "@id": "urn:nrel_example/nrel00000744",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000306"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001262"
+ "@id": "http://qudt.org/vocab/quantitykind/Energy"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/KiloW-HR"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000328"
+ "@value": "nrel00000744"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001139",
+ "@id": "urn:nrel_example/nrel00000478",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000474"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@value": "nrel00001139"
+ "@id": "urn:nrel_example/nrel00000708"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00001117",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000345"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001117"
+ "@value": "nrel00000478"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000843",
+ "@id": "urn:nrel_example/nrel00000285",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "urn:nrel_example/nrel00000059"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001161"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000843"
+ "@value": "nrel00000285"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001035",
+ "@id": "urn:nrel_example/nrel00000985",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/IN_H2O"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001035"
+ "@value": "nrel00000985"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000484",
+ "@id": "urn:nrel_example/nrel00000050",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000059"
- }
- ],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
- {
- "@id": "urn:nrel_example/nrel00000282"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000113"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000484"
+ "@value": "nrel00000050"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000007",
+ "@id": "urn:nrel_example/nrel00001308",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil"
+ "http://data.ashrae.org/standard223#Fan"
],
"http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:nrel_example/nrel00000383"
+ "@id": "urn:nrel_example/nrel00000291"
},
{
- "@id": "urn:nrel_example/nrel00000749"
+ "@id": "urn:nrel_example/nrel00000496"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "urn:nrel_example/nrel00000970"
},
{
- "@id": "urn:nrel_example/nrel00001042"
+ "@id": "urn:nrel_example/nrel00001207"
}
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000430"
+ "@id": "urn:nrel_example/nrel00000283"
},
{
- "@id": "urn:nrel_example/nrel00000715"
+ "@id": "urn:nrel_example/nrel00000651"
},
{
- "@id": "urn:nrel_example/nrel00000903"
+ "@id": "urn:nrel_example/nrel00000661"
},
{
- "@id": "urn:nrel_example/nrel00001256"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "@id": "urn:nrel_example/nrel00000674"
+ },
{
- "@id": "urn:nrel_example/nrel00000795"
+ "@id": "urn:nrel_example/nrel00000811"
},
{
- "@id": "urn:nrel_example/nrel00000946"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000963"
+ },
{
- "@value": "nrel00000007"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000228",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "@id": "urn:nrel_example/nrel00001016"
+ },
{
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "urn:nrel_example/nrel00001132"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001272"
+ },
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "urn:nrel_example/nrel00001273"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001331"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000228"
+ "@value": "nrel00001308"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001053",
+ "@id": "urn:nrel_example/nrel00000114",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Energy"
+ "@id": "urn:nrel_example/nrel00000600"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW-HR"
+ "@id": "urn:nrel_example/nrel00000477"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000594"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001053"
+ "@value": "nrel00000114"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000380",
+ "@id": "urn:nrel_example/nrel00000111",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000380"
+ "@value": "nrel00000111"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001063",
+ "@id": "urn:nrel_example/nrel00000961",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -28539,130 +28478,173 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001063"
+ "@value": "nrel00000961"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000086",
+ "@id": "urn:nrel_example/nrel00000904",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#CoolingCoil"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ "@id": "urn:nrel_example/nrel00000112"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000123"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW"
+ "@id": "urn:nrel_example/nrel00000248"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000874"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000973"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000996"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000140"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000298"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000330"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001239"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001317"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000086"
+ "@value": "nrel00000904"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000682",
+ "@id": "urn:nrel_example/nrel00001278",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Duct"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:nrel_example/nrel00001260"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001311"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000682"
+ "@value": "nrel00001278"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000664",
+ "@id": "urn:nrel_example/nrel00000166",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000664"
+ "@value": "nrel00000166"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000812",
+ "@id": "urn:nrel_example/nrel00000647",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:nrel_example/nrel00000150"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000836"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:nrel_example/nrel00000052"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000360"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000812"
+ "@value": "nrel00000647"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000554",
+ "@id": "urn:nrel_example/nrel00000375",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000554"
+ "@value": "nrel00000375"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000594",
+ "@id": "urn:nrel_example/nrel00001061",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000594"
+ "@value": "nrel00001061"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000619",
+ "@id": "urn:nrel_example/nrel00001311",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -28671,12 +28653,12 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000619"
+ "@value": "nrel00001311"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000921",
+ "@id": "urn:nrel_example/nrel00000389",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -28687,22 +28669,14 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000921"
+ "@value": "nrel00000389"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000813",
+ "@id": "urn:nrel_example/nrel00001229",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00001107"
- },
- {
- "@id": "urn:nrel_example/nrel00001302"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -28711,35 +28685,58 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000813"
+ "@value": "nrel00001229"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000604",
+ "@id": "urn:nrel_example/nrel00000135",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#HeatingCoil"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:nrel_example/nrel00001136"
+ "@id": "urn:nrel_example/nrel00000340"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000734"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000906"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00001255"
+ "@id": "urn:nrel_example/nrel00000051"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000075"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000914"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001250"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000202"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000740"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000604"
+ "@value": "nrel00000135"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001248",
+ "@id": "urn:nrel_example/nrel00000850",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
@@ -28748,52 +28745,55 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001248"
+ "@value": "nrel00000850"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000822",
+ "@id": "urn:nrel_example/nrel00001300",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000355"
- },
- {
- "@id": "urn:nrel_example/nrel00000438"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000822"
+ "@value": "nrel00001300"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000133",
+ "@id": "urn:nrel_example/nrel00001201",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000432"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00001235"
+ "@value": "nrel00001201"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001099",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000133"
+ "@value": "nrel00001099"
}
]
}