run_PTOsizing_SVV.m
163 lines (154 loc) · 6.33 KB
/
run_PTOsizing_SVV.m
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
% run_PTOsizing.m script m-file
% AUTHORS:
% Jeremy Simmons (email: [email protected])
% University of Minnesota
% Department of Mechanical Engineering
%
% CREATION DATE:
% July 24, 2023
%
% PURPOSE:
% The purpose of this script is to perform a design for a wave-powered
% reverse osmosis system operating in a known distibution of sea conditions
% given a PTO architecture, WEC-driven pump displacement, and install RO
% membrane area. The design is specified in the script under the section
% heading "Variables".
%
% The models used in the design are simple, static models with that
% include two-way coupling with the time-averaged simulation results of a
% WEC; the coupling is set up such that the reaction force from the PTO is
% a function of the average WEC speed (or power absortion) and the average
% WEC speed (or power absorption) is function of the reaction torque from
% the PTO.
%
% In the design, the WEC-driven pump displacement and RO module
% membrane area are varied across a grid of values. For each set
% of these design variables, an optimization is performed to select the
% nominal operating pressure of the system (either the RO feed pressure or
% the pressure at the outlet of the WEC_driven pump depending on the PTO
% architecture) and the switching duty (if applicable). This routine is
% performed for each sea state.
%
% The optimization of the operating pressure and switching duty is a
% nonlinear, constrained optimization which seeks to maximize the permeate
% production subject to the following constraints:
% 1) the electrical power production meets or exceeds the electrical demand
% 2) the operating pressure at the RO module is within a prescribe range
% If the design does not meet these constraints, the value of zero is
% recorded as the permeate production rate for that design.
%
% Once the results are obtained for the specified grid of design
% parameters, design parameters are selected for each sea state to give
% optimal combinations based on four possible configurations:
% A) the WEC-driven pump and RO module size are fixed across all sea
% conditions
% B) the WEC-driven pump is variable across all sea states while the active
% RO module size is fixed
% C) the active RO module size is variable across all sea states while the
% WEC-driven pump displacement is fixed.
% D) Both the WEC-driven pump and active RO module size are variable across
% all sea states
% The design combinations are organized based on the largest allowable
% value for the two design parameters; the design parameters are selected
% for each sea state from the set of designs that have design parameters
% values are less than or equal to the maximum allowable value, when
% variable by sea state. Otherwise, when the design parameter is fixed
% across the sea states, the set includes only designs that have the same
% value of the fixed design parameter. The design with greatest permeate
% production is selected from the set of available designs in each sea
% state.
%
%
% FILE DEPENDENCIES:
% PTOsizing_multiSS.m
% zero2nan.m
% parameters_timeAvePTO.m
% loadColors.m
% data_coulombPTO_dampingStudy_24-Aug-2022_1_slim.mat
% data_coulombPTO_dampingStudy_6SS_20230724_slim.mat
%
% UPDATES
% 07/24/2023 - created from study_PTOsizing.m.
%
% Copyright (C) 2023 Jeremy W. Simmons II
%
% This program is free software: you can redistribute it and/or modify
% it under the terms of the GNU General Public License as published by
% the Free Software Foundation, either version 3 of the License, or
% (at your option) any later version.
%
% This program is distributed in the hope that it will be useful,
% but WITHOUT ANY WARRANTY; without even the implied warranty of
% MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
% GNU General Public License for more details.
%
% You should have received a copy of the GNU General Public License
% along with this program. If not, see <https://www.gnu.org/licenses/>.
%
%% %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
clear
clc
%% %%%%%%%%%%%% SIMULATION/DESIGN PARAMETERS %%%%%%%%%%%%%%%%%%%%%%%%%%%
% Initialize parameter structure and get misc. base parameters
par = parameters_timeAvePTO();
% bounds on pressures in system
bounds.p_f_bnds = [4e6 8e6]; % [Pa/Pa] Bounds for feed pressure
bounds.p_w_bnds = [4e6 30e6]; % [Pa/Pa] Bounds for pressure at WEC driven pump
bounds.D_bnds = [0.1 1]; % [-] bounds for valve switching duty
% WEC: load time averaged results for WEC performance
switch 1
case 1
filename_WECpowerCurve = 'data_coulombPTO_dampingStudy_20220927_slim.mat';
SSset = 1:114;
case 2
filename_WECpowerCurve = 'data_coulombPTO_dampingStudy_6SS_20230724_slim.mat';
SSset = 1:6;
end
par.SSset = SSset;
load(filename_WECpowerCurve)
par.T_c_data = T_c_data; % [Nm] Torque applied to WEC by PTO
par.PP_w_data = PP_w_data; % [W] Power transmitted by WEC to PTO
par.weight = weight;
par.Hs = Hs;
par.Tp = Tp;
clearvars T_c_data PP_w_data weight Hs Tp
%% %%%%%%%%%%%% Variables %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
% Available PTO configurations
PTOarray = [1 1 3 3 4 1 1 3 3 4];
design_case = [1 2 1 2 1 3 4 3 4 3];
% Specified design
iPTO = 9;
% WEC-driven pump displacement
D_w = 0.116680785383119;
f_D_w = 0.01;
inc_D_w = (0.01)*D_w;
% Total Ro membrane area;
S_ro = 3700;
f_S_ro = 0.01;
inc_S_ro = 37;
% ERU configuration
ERUconfig = 1; % 0-w/o ERU; 1-w/ ERU
% Create array of displacement and memebrane area if these are variable.
% WEC-driven pump displacment
if design_case(iPTO) == 2 || design_case(iPTO) == 4
min_D_w = inc_D_w*(floor(f_D_w*D_w/inc_D_w)+(mod(D_w*f_D_w,inc_D_w)>0));
D_wArray = min_D_w:inc_D_w:D_w; % [m^3/s] displacement
else
D_wArray = D_w;
end
% membrane area in RO module
if design_case(iPTO) == 3 || design_case(iPTO) == 4
min_S_ro = inc_S_ro*(floor(f_S_ro*S_ro/inc_S_ro)+(mod(S_ro*f_S_ro,inc_S_ro)>0));
S_roArray = min_S_ro:inc_S_ro:S_ro; % [m^3/s] displacement
else
S_roArray = S_ro;
end
%% %%%%%%%%%%%% COLLECT DATA %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
tic
data = PTOsizing_multiSS(D_wArray,S_roArray, ...
bounds,PTOarray(iPTO),design_case(iPTO), ...
ERUconfig,par);
toc
%% %%%%%%%%%%%% SAVE DATA %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
filename = ['data_PTOsizing_SVV_',char(datetime("now",'Format','yyyyMMddHHmmss'))];
save(filename,'-v7.3')