// Licensed to the .NET Foundation under one or more agreements.
// The .NET Foundation licenses this file to you under the MIT license.
using System;
namespace Iot.Device.Imu
{
[Flags]
internal enum UserControls
{
None = 0b0000_0000,
// 1 – Reset all gyro digital signal path, accel digital signal path, and temp digital signal path.
// This bit also clears all the sensor registers. SIG_COND_RST is a pulse of one clk8M wide.
SIG_COND_RST = 0b0000_0001,
// 1 – Reset I2C Master module. Reset is asynchronous. This bit auto clears after one clock cycle.
// NOTE: This bit should only be set when the I2C master has hung. If this bit is set during an active I2C master transaction,
// the I2C slave will hang, which will require the host to reset the slave.
I2C_MST_RST = 0b0000_0010,
// 1 – Reset FIFO module. Reset is asynchronous. This bit auto clears after one clock cycle
FIFO_RST = 0b0000_0100,
// 1 – Reset I2C Slave module and put the serial interface in SPI mode only. This bit auto clears after one clock cycle.
I2C_IF_DIS = 0b0001_0000,
// 1 – Enable the I2C Master I/F module; pins ES_DA and ES_SCL are isolated from pins SDA/SDI and SCL/ SCLK.
// 0 – Disable I2C Master I/F module; pins ES_DA and ES_SCL are logically driven by pins SDA/SDI and SCL/ SCLK.
// NOTE: DMP will run when enabled, even if all internal sensors are disabled, except when the sample rate is set to 8Khz
I2C_MST_EN = 0b0010_0000,
// 1 – Enable FIFO operation mode.
// 0 – Disable FIFO access from serial interface.
// To disable FIFO writes by dma, use FIFO_EN register.
// To disable possible FIFO writes from DMP, disable the DMP.
FIFO_EN = 0b0100_0000,
}
}