Overview

  • Task: Segment aorta on CT. This method produces results quickly, without requiring too much user input. The same method can be used for segmenting other structures that have a good contrast compared to the background but there are other structures with similar intensity nearby.
  • Imaging modality: any

Prerequisites

  • SegmentEditorExtraEffects extension is installed.
  • Contrast-enhanced CT volume is loaded.

Recommended workflow

  • Click Paint effect and paint a few strokes inside the aorta.
  • Click Fast Marching effect.
  • Set Maximum volume to 1% (since volume of the aorta is very small compared to the total volume of the CT image).
  • Click Initialize to compute segmentation preview.
  • Adjust segment volume slider to achieve complete segmentation, but not too high value (to prevent leaking out of the aorta).
  • Click Apply when segmentation preview is satisfactory to finalize the segmentation.
  • Apply Smoothing effect, Median method to fill in missed voxels and smooth outer surface of the vessel.

Tips:

  • If Fast Marching not visible then install SegmentEditorExtraEffects extension and restart the application
  • To make paint strokes more visible, you can deactivate Paint effect and left-click-and-drag in the slice view to change background volume window/level.
  • To see preview in 3D view: Click the down-arrow button on the right side of Show 3D button and disable Surface smoothing (this will make updates of 3D visualization very fast). Click Show 3D button.
  • If a large piece of the aorta is missed then click Cancel, use Paint effect to paint inside the area that is missing, then re-initialize Fast Marching effect as described above.

Example

  • Download CTACardio sample data set
  • Go to Segment editor module, click Add button to create a new segment
  • Select Paint effect and paint a few strokes inside the aorta.

Seeds painted inside the aorta.

  • Click Fast Marching effect
  • Set Maximum volume to 1% (since volume of the aorta is very small compared to the total volume of the CT image)
  • Click Initialize to compute segmentation preview.
  • Adjust segment volume slider to achieve complete segmentation, but not too high value, to prevent leaking out of the aorta.

Seeds painted inside the aorta.

  • To see preview in 3D view: Click the down-arrow button on the right side of Show 3D button and disable Surface smoothing, then click Show 3D button.

Disable surface smoothing for fast updates in 3D view.

Preview segmentation result in 3D.

  • Click Apply when segmentation preview is satisfactory.
  • Apply Smoothing effect, Median method to fill in missed voxels and smooth outer surface of the vessel.

Final result.

Final result:

Animation of final result.