import logging
import numpy as np
import pandas as pd
import pandapower as pp
def find_value_for_pp_bus(grid: pp.pandapowerNet,
voltages_from: np.ndarray,
voltages_to: np.ndarray,
bus: int):
# map line extremity voltage readings to the correct pandapower bus
bus_vn_kv = grid.bus.loc[bus, "vn_kv"]
for idx, line in enumerate(grid.line.itertuples()):
if line.from_bus == bus:
return voltages_from[idx] / bus_vn_kv
elif line.to_bus == bus:
return voltages_to[idx] / bus_vn_kv
for idx, trafo in enumerate(grid.trafo.itertuples()):
if trafo.hv_bus == bus:
return voltages_from[len(grid.line) + idx] / bus_vn_kv
elif trafo.lv_bus == bus:
return voltages_to[len(grid.line) + idx] / bus_vn_kv
return None
def calc_losses(grid: pp.pandapowerNet):
# calculate grid losses
return grid.res_gen.p_mw.sum() + grid.res_ext_grid.p_mw.sum() + grid.res_sgen.p_mw.sum() - grid.load.p_mw.sum()
def make_zero_idx(elements: pd.DataFrame,
pd_indices,
offset: int = 0):
# translate arbitrary pandas indices to 0-based numpy array indices
return [elements.index.get_loc(lidx) + offset for lidx in pd_indices]
def run_opf(grid: pp.pandapowerNet,
min_loss_reduction_mwt: float,
acceptable_loading: float,
opf_type: str,
asset: str = "",
logger=logging.getLogger()):
loss_before = calc_losses(grid)
line_loading_before = grid.res_line.loading_percent.max()
trafo_loading_before = grid.res_trafo.loading_percent.max()
try:
if opf_type == "pypower":
grid.ext_grid["min_p_mw"][0] = -100
grid.ext_grid["max_p_mw"][0] = 200
pp.runopp(grid) # pypower OPF
elif opf_type == "powermodels":
grid.line["in_service"] = True
grid.trafo["in_service"] = True
pp.runpm_ots(grid, pm_nl_solver="ipopt", pm_model="ACPPowerModel") # PowerModels.jl OPF
grid.line.loc[:, "in_service"] = grid.res_line.loc[:, "in_service"].values.astype(bool)
grid.trafo.loc[:, "in_service"] = grid.res_trafo.loc[:, "in_service"].values.astype(bool)
generation = np.array(grid.res_gen.p_mw.tolist() + grid.res_ext_grid.p_mw.tolist())
losses_avoided = loss_before - calc_losses(grid)
line_loading_after = grid.res_line.loading_percent.max()
trafo_loading_after = grid.res_trafo.loading_percent.max()
use_opf_results = False
# three conditions for using the OPF results:
# 1. transformer was overloaded before and is now less overloaded
# 2. line was overloaded before and is now less overloaded
# 3. losses are minimized at least by "min_loss_reduction_mwt" while all loadings are acceptably low
if trafo_loading_before > acceptable_loading and trafo_loading_after < trafo_loading_before:
use_opf_results = True
if line_loading_before > acceptable_loading and line_loading_after < line_loading_before:
use_opf_results = True
if losses_avoided > min_loss_reduction_mwt and line_loading_after < acceptable_loading and trafo_loading_after < acceptable_loading:
use_opf_results = True
if use_opf_results:
logger.info(f"Losses avoided: {losses_avoided:.3f} MW (max. loading: {line_loading_after:.1f}% [{line_loading_after - line_loading_before:.1f}%] "
f"/ Trafo: {trafo_loading_after:.1f}% [{trafo_loading_after - trafo_loading_before:.1f}%])")
return generation, grid.line.in_service, grid.trafo.in_service, True
return np.zeros(len(grid.gen)), grid.line.in_service, grid.trafo.in_service, False
except pp.optimal_powerflow.OPFNotConverged:
asset_str = f"if asset #{asset} is out of service" if len(asset) else ""
logger.info(f"OPF failed {asset_str}")
return np.zeros(len(grid.gen)), grid.line.in_service, grid.trafo.in_service, False