spectrum normalize_at_point "dx" not working properly #1

Open
jbudynk opened this issue May 14, 2014 · 0 comments
Open

spectrum normalize_at_point "dx" not working properly #1

jbudynk opened this issue May 14, 2014 · 0 comments
Assignees

Comments

@jbudynk
Copy link
Owner

jbudynk commented May 14, 2014

find_ranges doesn't work properly. It finds all values between x0-dx and x0+dx, rather than spec[index_near_x0 - dx: index_near_x0 + dx]. "dx" is supposed to be the number of points to average around x0, not +/i the value of x0.

@jbudynk jbudynk added the bug label Jul 9, 2014
@jbudynk jbudynk self-assigned this Jul 9, 2014
@jbudynk jbudynk added the P2 label Jul 9, 2014