sometimes float is not enough (for example when calculating critical radius)

@pdziekan
Copy link
Contributor

After it's done, put real_t instead of double in all places that so far required a double (everywhere?).

@trontrytel
Copy link
Collaborator Author

After it's done revert pull request #228 (Fix critical radius calculation by forcing double precision)