You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
This is feature request about adding support for adaptec flash+battery/supercap cache protection modules (instead of typical ram+battery) like AFM-700 in --bbu-monitoring option.
--------------------------------------------------------
Controller Cache Backup Unit Information
--------------------------------------------------------
Overall Backup Unit Status : Ready
Backup Unit Type : AFM-700/700LP
Non-Volatile Storage Status : Ready
Supercap Status : Ready
-----------------------------------
Supercap Information
-----------------------------------
Current Temperature : 34 deg C
Threshold Temperature : 51 deg C
Life-time Temperature Recorded
(Min/Max) : 19 deg C/ 52 deg C
Voltage(Present/Max) : 4925 mV/ 5302 mV
Life-time Max Voltage Recorded : 5432 mV
Current Drawn(Present/Max) : -11 mA/ 560 mA
Health : 100 percent
Charge Level : 100 percent
Estimated Life-time : 5 Years, 0 Month
Serial Number : 4A381D8CB65
----------------------------------------------------------------------
Output of check_raid -d:
# /usr/lib/nagios/plugins/check_raid -d --bbu-monitoring
check_raid 4.0.8-dev
Visit <https://github.com/glensc/nagios-plugin-check_raid#reporting-bugs> how to report bugs
Please include output of **ALL** commands in bugreport
DEBUG EXEC: /sbin/dmsetup status --noflush at /usr/share/perl5/vendor_perl/App/Monitoring/Plugin/CheckRaid/Plugin.pm line 385.
DEBUG EXEC: /sbin/arcconf GETSTATUS 1 at /usr/share/perl5/vendor_perl/App/Monitoring/Plugin/CheckRaid/Plugin.pm line 385.
DEBUG EXEC: /sbin/arcconf GETCONFIG 1 AL at /usr/share/perl5/vendor_perl/App/Monitoring/Plugin/CheckRaid/Plugin.pm line 385.
OK: arcconf:[Controller:Optimal, Logical Device 0(ROOTFS):Optimal, Logical Device 1(SWAP):Optimal, Logical Device 2(DATA):Optimal, Drives: PN2234P9HNSEBY,PN2234P8KMM9BY,PN2234P9HN6E5Y,PN2234P9HNDW9Y=Online]
# /usr/lib/nagios/plugins/check_raid -d --bbu-monitoring
check_raid 4.0.10-1
Visit <https://github.com/glensc/nagios-plugin-check_raid#reporting-bugs> how to report bugs
Please include output of **ALL** commands in bugreport
DEBUG EXEC: /sbin/dmsetup status --noflush at /usr/share/perl5/vendor_perl/App/Monitoring/Plugin/CheckRaid/Plugin.pm line 404.
DEBUG EXEC: /proc/mdstat at /usr/share/perl5/vendor_perl/App/Monitoring/Plugin/CheckRaid/Plugin.pm line 404.
DEBUG EXEC: /sbin/arcconf GETSTATUS 1 at /usr/share/perl5/vendor_perl/App/Monitoring/Plugin/CheckRaid/Plugin.pm line 404.
DEBUG EXEC: /sbin/arcconf GETCONFIG 1 AL at /usr/share/perl5/vendor_perl/App/Monitoring/Plugin/CheckRaid/Plugin.pm line 404.
This is feature request about adding support for adaptec flash+battery/supercap cache protection modules (instead of typical ram+battery) like AFM-700 in --bbu-monitoring option.
https://www.adaptec.com/nr/pdfs/AFM700_ds.pdf
Relevant part is:
Output of
check_raid -d
:Output of each command from
check_raid -d
raid-dmsetup.txt
raid-getconfig.txt
raid-getstatus.txt
The text was updated successfully, but these errors were encountered: