v3.7.1 (2021-06-05)
Implemented enhancements:
- Better management of inconsistent UIDs between the manifest and the file #186
- Support service account auth for Cloud Healthcare API integration #125
Fixed bugs:
- Trailing whitespace in AE title of DICOM node #192
- Uppercase DCM Files cannot be imported #190
- GSPS object is not rendered properly #181
- Weasis 3.7 fails to register the weasis:// protocol on macOS #180
- Sorting channel issue in ECG #178
- On Windows the Dicomizer exe launches the viewer #176
v3.7.0 (2021-02-02)
Implemented enhancements:
- Handle spatial calibration of US with multiple regions (only when a single region in cm is present) #169
- Update to weasis-dicom-tools 5.23.0.1 #167
- Update to OpenCV 4.5.0 #166
- Make the STOW-RS URL compatible with the DICOMWeb API #164
- Add DICOMWeb support in DICOM Query/Retrieve dialog #161
- Add graphic object opacity of DICOM Presentation State #153
Fixed bugs:
- Fix overriding weasis.resources.url in VM option or in command $weasis:config #165
- Raw RGB images encoded in bigendian are not rendered correctly #154
v3.6.2 (2020-08-26)
Implemented enhancements:
- Weasis shows green hues instead of black in JPEG-compressed Ultrasound images #140
Fixed bugs:
- Cannot read signed data with PaletteColor #148
- DICOM Print: warning DICOM status is treated as an error #147
- Cannot start MPR for series containing ISO 2022 IR 149 charset #144
- Not all colors are displayed correctly in DICOM PR graphics #143
- Cannot add http headers when creating a new WEB Node #142
- Poor image display with a more than 100% factor in the Window 10 display settings. #141
- Cannot retrieve thumbnail with WADO-URI request #139
v3.6.1-3D (2020-07-14)
v3.6.0-3D (2020-07-14)
v3.6.1 (2020-07-03)
Implemented enhancements:
- Use weasis-core-img 4.3.0 and remove jai_imageio dependency #135
- Update radiance to 3.0.0 for the native distribution #134
- Remembering Window position and size #123
Fixed bugs:
- Fix applying VOI Lut with a Presentation LUT and when there is no lookup table #133
- Fix patientid containing special characters in dicomweb command #132
- Command for loading DICOM locally doesn't work on Windows #128
- Opening files with Polish diacritic signs doesn't work on Windows #126
- Chinese charset exception when reading dataset #119
- Weasis 3.5.4 crashes on OS X 10.15.2 #116
v3.6.0 (2020-02-21)
Implemented enhancements:
- Define a minimal local version for loading the remote plug-ins #113
Fixed bugs:
- Remove pack200 compression in Java 14 (replace by xz for plug-in files) #117
v3.6.0-rc1 (2020-02-03)
Implemented enhancements:
- Always set the Dose Report series at the end when sorting series #110
Fixed bugs:
- Cannot display 16-bit image with DICOM PALETTE_COLOR #112
- Mouse cursor is moving on the Weasis window (when already open) #108
- NPE when loading a manifest #107
- Issue of sorting series order #105
v3.5.4 (2019-11-01)
Implemented enhancements:
- DICOMWeb query/retrieve with a new command "dicom:rs" #102
Fixed bugs:
- Some menus are freezing #104
- The language modules are not load from the server side #101
- Http redirection not working when downloading (regression) #100
- Fix covariant return types in ByteBuffer introduced in Java 9 #99
- HTTPS download error: handshake_failure #98
- Images blanking out randomly #43
3.5.4-rc (2019-09-27)
v3.5.3 (2019-08-09)
Implemented enhancements:
- Configuration of proxy server in GUI #91 [Type: Feature]
- Weasis binaries does not launch in MacOS Mojave #85 [Type: Security]
- DICOM send is not able to transcode when the receiver has limited syntaxes #82
- Add median, skewness, kurtosis and entropy for statistics of an area #79
- Supports modality LUT (table) when displaying LUT values #77
- Allow to add custom HTTP headers for DICOMWeb nodes #74 [Type: Feature]
- Histogram view #73 [Type: Feature]
- API for getting a remote configuration at startup (profile, user, properties...) #66 [Type: Feature]
- API to handle preferences remotely #65 [Type: Feature]
- HiDPI support #64 [Type: Feature]
- Package for installing on Windows, Mac and Linux #57 [Type: Feature]
Fixed bugs:
- Issues on images with BitsAllocated (0028,0100) set to 16 and BitsStored (0028,0101) set to 8 #94
- .deb Linux package crash: java.lang.IllegalArgumentException: invalid version #93
- Render issue with MeasurementUnitsCodeSequence in DICOM SR #90
- Issue when reseting a Presentation State #87
- Cannot change W/L when a Presentation LUT is applied #86
- Cannot export DICOM PDF and Video #84
- Cannot render DICOM SR #83
- Exporting jpeg images doesn't work with some patient names #81
- Measurement statistics doesn't use modality LUT (table) #78
- Do not apply LUT shape when displaying LUT (only linear) #76
- Some numbers doesn't apply the regional format selected in the preferences #75
- The displayed image becomes black after exporting series in jpeg or png #72
- Cannot write MPR images on Windows when the path contain non-ASCII characters #69
v3.5.1 (2019-03-24)
Implemented enhancements:
- The same name of the system process for every platform #67
- A single instance mechanism for all the launch context #63 [Type: Feature]
- Allow to enable app sandbox on Mac OS X #62
- Integration of the Mac OS X application menu #61 [Type: Feature]
- Improves the traces of the launcher module #60
- Register the DICOM mime type for file association (for windows .dcm extension) #59 [Type: Feature]
- Register an URI handler for the weasis and weasis-dicomizer scheme #58 [Type: Feature]
- Supporting from Java 8 to Java 13 Runtime #56
- Allow to embed JRE for Linux and Mac #38 [Priority: Medium]
Fixed bugs:
- 3D Stl file Open Does not work #68
- Open image menu or toolbar should not appear on Dicomizer #55
- W/L issue with MR containing Modality LUT values #52 [Priority: High]
3.0.4 (2018-12-20)
Implemented enhancements:
- Allows configuring HTTP timeout of WADO through properties #50
- Cannot display color image with 16-bit per channel #49
- Http redirection not supported when downloading images #46 [Priority: Low]
- HTTP read timeout when downloading manifest or images #45
Fixed bugs:
- Duplicate presets with DICOM PR and CT #48
- Selected graphic does not get updated #44 [Priority: High]
Merged pull requests:
- Extend GUI for plan/dose selection #24 (toskrip)
- Fix isodose rendering #23 (toskrip)
- Fix plan initialisation and isodose rendering #22 (toskrip)
- Dicom rt plugin #21 (toskrip)
3.0.3 (2018-11-07)
Implemented enhancements:
- Read SCOORD with a reference to an image (DICOM SR) #41
- Update to weasis-dicom-tools 5.14.1 #40
- Reduce default margins for standard print #35 [Priority: Low]
Fixed bugs:
- In Crosshair mode releasing Ctrl do not deactivate W/L (issue only on Windows) #37 [Priority: Medium]
- Native decoders only work with recent Linux distributions #36 [Priority: High]
- TransferSyntaxUID is duplicated when saving generated DICOM files #34 [Priority: High]
- Weasis 3.0.2 not exporting MPR reformats #33 [Priority: Medium]
3.0.2 (2018-09-17)
Bug
- [WEA-469] - Cannot display images with invalid dates
- [WEA-470] - Cannot open several ECGs from the same patient
- [WEA-475] - Cannot build thumbnails (UTF8 path issue on Windows)
- [WEA-476] - Open non-DICOM image issue (UTF8 path issue on Windows)
- [WEA-480] - Filter for non-DICOM images doesn't match to available image decoders
- [WEA-483] - Export the selected view to the clipboard doesn't work
New Feature
- [WEA-474] - Toolbar with import and export DICOM buttons
- [WEA-481] - Allow to open non-DCIOM jpeg2000 images
Improvement
- [WEA-472] - Update to apache felix 6.0.1
- [WEA-473] - Improve DICOM STOW
- [WEA-477] - Add shortcuts for rotation and flip
- [WEA-478] - Update to weasis-dicom-tools 5.13.4
- [WEA-479] - Allows switching from crosshair to W/L (by Ctrl + click)
- [WEA-482] - Right-clicking on the main toolbar to show/hide toolbars
3.0.1 (2018-05-14)
Bug
- [WEA-458] - Tool panels are not visible with some screen sizes
- [WEA-460] - Do not update patient age when selecting another study
- [WEA-461] - Cannot launch Weasis (Failed to validate certificate)
- [WEA-462] - Update dcm4che to 5.13.0
- [WEA-464] - Thumbnails cannot be resized
- [WEA-465] - Default Color issue in PR graphics
- [WEA-467] - Re-creates missing download folder when system delete it
- [WEA-468] - Query/Retrieve with C-Move doesn't work (Regression)
Improvement
- [WEA-463] - Display the vertical LUT from the bottom to the top
- [WEA-466] - Update to substance 8.0.2
2.6.3 (2018-05-14)
Full Changelog Bug
- [WEA-458] - Tool panels are not visible with some screen sizes
- [WEA-460] - Do not update patient age when selecting another study
- [WEA-461] - Cannot launch Weasis (Failed to validate certificate)
- [WEA-465] - Default Color issue in PR graphics
- [WEA-467] - Re-creates missing download folder when system delete it
- [WEA-468] - Query/Retrieve with C-Move doesn't work (Regression)
Improvement
- [WEA-463] - Display the vertical LUT from the bottom to the top
- [WEA-466] - Update to substance 8.0.2
3.0.0-RC1 (2018-03-02)
Bug
- [WEA-419] - Selection of key images doesn't work with mulitframe
- [WEA-421] - Weasis cannot start
- [WEA-422] - Display issue when patient name is different from the one in the xml manifest
- [WEA-426] - Several fixes for being compliant with Java 9
- [WEA-440] - Cannot download images when overriding tags in the xml manifest
- [WEA-441] - Cannot deploy weasis.war in dcm4chee 5.10.6
- [WEA-442] - Fix JWS cache issue. Allow to use jar version in jnlp
- [WEA-443] - Cannot display DICOM LUT with jpeg images
- [WEA-444] - Window/Level gets infinity values with a single value image (other than 0)
- [WEA-445] - Dicom tags view displays information from another view
- [WEA-447] - Force replacing JPEG Baseline RGB color model into YBR_FULL_422 (fixes DICOM error of some constructors)
- [WEA-448] - Fix win/level issue in a series with a full black image
- [WEA-451] - Weasis portable doesn't support Java 9
- [WEA-454] - Bug fix JAI_IMAGEIO_CORE-126 : Under heavy multi-threaded load, native sse2 library randomly fails and brings down the whole JVM
- [WEA-455] - Bug fix JAI_IMAGEIO_CORE-189 : j2k lossy issue
- [WEA-456] - Fix artefact with native jpeg2000 decoder
- [WEA-457] - Fix color model issue of jpeg-ls and jpeg
New Feature
- [WEA-423] - Connection of the dicomizer to a DICOM Worklist
- [WEA-452] - ECG viewer
- [WEA-453] - New image decoding and processing workflow based on OpenCV
Improvement
- [WEA-484] - weasis-portable
2.6.2 (2018-03-02)
Bug
- [WEA-444] - Window/Level gets infinity values with a single value image (other than 0)
- [WEA-445] - Dicom tags view displays information from another view
- [WEA-446] - Close Other, from tabs menu leaves selected tab without mouse functions
- [WEA-447] - Force replacing JPEG Baseline RGB color model into YBR_FULL_422 (fixes DICOM error of some constructors)
- [WEA-448] - Fix win/level issue in a series with a full black image
- [WEA-449] - DICOM Listener with C-Move doesn't work
- [WEA-450] - Graphics of DICOM PR stay visible when selected None
- [WEA-451] - Weasis portable doesn't support Java 9
Merged pull requests:
- Re-creates missing download folder if needed. #29 (gabibau)
- Fix some typos (found by codespell) #28 (stweil)
- Makes Measurements pointers customizable. #27 (gabibau)
- Weasis uses PatientPseudoUID to compare different patients #26 (felipefetzer)
- Number of instances on export checktree #25 (gabibau)
2.6.1 (2017-12-08)
Bug
- [WEA-435] - Path issue for sub-folder configuration of the portable distribution on Windows
- [WEA-437] - In some cases cross-lines are not displayed
- [WEA-438] - C-Move retrieve issue (cannot start DicomListener)
- [WEA-439] - The LUT palette on the image is inverted
- [WEA-440] - Cannot download images when overriding tags in the xml manifest
- [WEA-441] - Cannot deploy weasis.war in dcm4chee 5.10.6
- [WEA-442] - Fix JWS cache issue. Allow to use jar version in jnlp
Improvement
- [WEA-436] - Change default encoding to ISO_IR 100 (ISO-8859-1)
2.6.0 (2017-09-08)
Bug
- [WEA-419] - Selection of key images doesn't work with mulitframe
- [WEA-421] - Weasis cannot start
- [WEA-422] - Display issue when patient name is different from the one in the xml manifest
- [WEA-426] - Several fixes for being compliant with Java 9
- [WEA-440] - Cannot download images when overriding tags in the xml manifest
- [WEA-441] - Cannot deploy weasis.war in dcm4chee 5.10.6
- [WEA-442] - Fix JWS cache issue. Allow to use jar version in jnlp
- [WEA-443] - Cannot display DICOM LUT with jpeg images
- [WEA-444] - Window/Level gets infinity values with a single value image (other than 0)
- [WEA-445] - Dicom tags view displays information from another view
- [WEA-447] - Force replacing JPEG Baseline RGB color model into YBR_FULL_422 (fixes DICOM error of some constructors)
- [WEA-448] - Fix win/level issue in a series with a full black image
- [WEA-451] - Weasis portable doesn't support Java 9
- [WEA-454] - Bug fix JAI_IMAGEIO_CORE-126 : Under heavy multi-threaded load, native sse2 library randomly fails and brings down the whole JVM
- [WEA-455] - Bug fix JAI_IMAGEIO_CORE-189 : j2k lossy issue
- [WEA-456] - Fix artefact with native jpeg2000 decoder
- [WEA-457] - Fix color model issue of jpeg-ls and jpeg
New Feature
- [WEA-423] - Connection of the dicomizer to a DICOM Worklist
- [WEA-452] - ECG viewer
- [WEA-453] - New image decoding and processing workflow based on OpenCV
Improvement
- [WEA-484] - weasis-portable
2.5.3 (2017-05-12)
Bug
- [WEA-396] - Changing the selected KO to None will let filter applied
- [WEA-400] - Study date is not updated in dicomizer when an image is removed
- [WEA-404] - Fix canceling DICOM send
- [WEA-406] - Fix the continuous errors of some corrupted images
- [WEA-408] - Fix series sorting issues
- [WEA-412] - Do not allow importing DICOM images in dicomizer
- [WEA-414] - Fix losing spatial unit with DICOM Presentation State
- [WEA-416] - Fix refreshing metada in Dicomizer
- [WEA-417] - Fix the offset position issue of the graphic label after serialization
New Feature
- [WEA-152] - DICOM Query / Retrieve (DICOM import plugin)
- [WEA-397] - Reattempt downloading images after network failure
Task
- [WEA-405] - Upgrade to weasis-dicom-tools 1.0.4
- [WEA-413] - Fix java 9 compilation and execution issues
Improvement
- [WEA-398] - In tile mode, limit the scroll according to the number of images and the layout size
- [WEA-401] - Make more readable the overlays on thumbnails
- [WEA-407] - Allow all the non sequence tags in attributes-view.xml
- [WEA-409] - Read SCOORD from DICOM SR and display graphics on the image
- [WEA-410] - Fix corrupted path for loading images on Windows
- [WEA-411] - Improve DICOM error message
- [WEA-415] - Configure the tags to display, to edit and to be required for publication in Dicomizer
2.5.2 (2017-02-22)
Bug
- [WEA-385] - The list of Key Object in explorer is missing
- [WEA-386] - Wrong pixel value with non square pixel image
- [WEA-388] - viewer linux launcher doesn't work
- [WEA-390] - Fix loading native bundles for Windows server 2012 and 2016
- [WEA-392] - Issue for identifying uniquely a patient
- [WEA-394] - DICOM SR are not visible in the explorer
- [WEA-395] - Fix upgrading issue (cache of configuration)
Task
- [WEA-393] - Update Felix framework to 5.6.1
Improvement
- [WEA-209] - Wrong frame rate for multiframe studies
- [WEA-387] - Remove temporary files when closing studies in UI
- [WEA-389] - Follows the POSIX syntax. Allows to run simultaneously different parameter types (Open DICOM)
- [WEA-391] - Menu for exporting studies to Horos on Mac
Merged pull requests:
2.5.0 (2016-11-15)
Bug
- [WEA-342] - Some DICOM VOI LUTs are not displayed correctly
- [WEA-346] - Artifacts with the pure Java JPEG2000 Decoder
- [WEA-352] - Scroll position of the DICOM metadata view is always on the bottom
- [WEA-353] - Removing a patient do not remove the list of Key Images
- [WEA-356] - Measurement Units are not displayed in DICOM SR view
- [WEA-359] - Cannot export DICOM Mpeg or DICOM pdf
- [WEA-361] - Default AETitle for printer SCU is not valid
- [WEA-364] - Checking "Selected View" option in DICOM Print doesn't work
- [WEA-370] - Close image from the context menu is not working
- [WEA-372] - Sometimes thumbnails of a split series are not displayed
- [WEA-374] - Mermory leak with some views
- [WEA-375] - Build MPR with images from other series
- [WEA-376] - WEASIS close any browser, when opening several large DICOMs
- [WEA-378] - Lens doesn't refresh graphics correctly
- [WEA-381] - Fix patient inconsistency within a study
- [WEA-383] - Green image with YBR_FULL and RLE compression
New Feature
- [WEA-337] - DICOM Send (DICOM export plugin)
- [WEA-363] - New cross-platform decoders: jpeg, jpeg-losseless, jpeg-ls, jpeg2000
- [WEA-371] - Command to open an non DICOM image file or URL
- [WEA-373] - Read new DICOM floating point image pixel
- [WEA-377] - Dicomizer module
- [WEA-379] - New drawing tools
- [WEA-380] - Option for exporting graphics in DICOM Presentation State
Task
- [WEA-345] - Replacing simpleXML (the XML binding library) by jaxb
- [WEA-368] - Build dynamically all the DICOM TagW
- [WEA-382] - Update to felix framework 5.6.0
Improvement
- [WEA-343] - Apply Presentation LUT sequence
- [WEA-344] - Reading Presentation State improvement for overlay, shutter
- [WEA-351] - check open Series' Studies in the Export dialog
- [WEA-354] - Minimal annotations mode available in Display tool
- [WEA-355] - Allow to read DICOM ZIP without DICOMDIR
- [WEA-357] - Display lossy compression information
- [WEA-358] - Allow to open serveral documents of a series (dicom encapsulated document)
- [WEA-360] - Exporting non DICOM files will allow to extract files from DICOM encapsulated document and DICOM video
- [WEA-362] - Allow in preferences to adapt the stacktrace limit in the logger
- [WEA-367] - File configuration of series splitting rules
- [WEA-369] - Image in low resolution with standard print
Merged pull requests:
- Change DicomFieldsView and InfoLayer so they work with other Explorer… #8 (gabibau)
- Small fixes: replaceView on ImageViewPlugin and a Graphic name. #7 (gabibau)
- Fixes Ellipse label preferences. #6 (gabibau)
2.0.7 (2016-05-20)
Bug
- [WEA-352] - Scroll position of the DICOM metadata view is always on the bottom
- [WEA-353] - Removing a patient do not remove the list of Key Images
- [WEA-356] - Measurement Units are not displayed in DICOM SR view
- [WEA-361] - Default AETitle for printer SCU is not valid
- [WEA-364] - Checking "Selected View" option in DICOM Print doesn't work
Improvement
- [WEA-351] - check open Series' Studies in the Export dialog
- [WEA-355] - Allow to read DICOM ZIP without DICOMDIR
- [WEA-357] - Display lossy compression information
- [WEA-369] - Image in low resolution with standard print
Merged pull requests:
- BasicGraphic sending measurement list by interface. #5 (gabibau)
-
- Updating surefire plugin version due to Netbeans compatibility issue #2 (pedrobastosz)
2.0.6 (2016-02-20)
Bug
- [WEA-346] - Artifacts with the pure Java JPEG2000 Decoder
- [WEA-348] - Cannot display some US images
- [WEA-349] - On Windows 10 and last Java Runtime compressed images cannot be displayed
Improvement
- [WEA-350] - Update to dcm4che 3.3.7 and felix framework 5.4.0
2.0.5 (2015-10-05)
Bug
- [WEA-329] - window/level issue when configured on two or more mouse buttons
- [WEA-331] - Does not support 16-bit Modality LUT on 8-bit monochrome image
- [WEA-332] - dcmview2d:move command do not move the image
- [WEA-333] - Cannot start on Windows 10 and Java 8_60 32-bit
- [WEA-334] - DICOMDIR reader doesn't load DICOM PR and KO
- [WEA-335] - Multiplication of loading progress bars with DICOMDIR reader
- [WEA-336] - Cannot build the distribution with spaces in path on non-Windows systems
- [WEA-339] - Reading color icon of DICOMDIR
- [WEA-340] - Cannot visualize the image with an invalid age value
New Feature
- [WEA-330] - Add the oriented minimum bounding box (OMBB) for polygon (by the minimum rectangle width)
Improvement
- [WEA-328] - Add contextual menu entries for open a series directly on another screen
- [WEA-338] - Show when DICOMDIR is corrupted and suggest reading files
- [WEA-341] - Display the thumbnail of the selected series on the center only when not visible
Merged pull requests:
- Move telnet command is working again #1 (alexsierro)
2.0.4 (2015-06-23)
Bug
- [WEA-280] - Sometimes a view disappears when externalizing a window on another screen
- [WEA-310] - Displaying measurement results in pixel is not correct
- [WEA-312] - Missing film size values in DICOM print
- [WEA-313] - Image without a spatial calibration should always show values in pixel unit
- [WEA-317] - Fix several issues with DICOM print
- [WEA-320] - Encoding issue when reading the WADO manifest
- [WEA-321] - Cache images are not removed during Windows shutdown or log off
- [WEA-325] - Fix log file path when using remote preferences
New Feature
- [WEA-308] - Allow to search within DICOM metadata
- [WEA-316] - DICOM Print: allow to print a layout (several images per page)
- [WEA-327] - DICOM Print Film Size options
Improvement
- [WEA-307] - Add a button for abording the import and export tasks
- [WEA-309] - Allow to drag and drop non DICOM images into the central empty area
- [WEA-314] - Update translations for launcher and Java Swing UI
- [WEA-315] - Update OSGI Felix framework to 4.6.1
- [WEA-319] - Update to launch4j 3.8 for building weasis.exe
- [WEA-322] - Display the keyboard shortcut of the measurement selection menu
- [WEA-323] - Add new keyboard shortcuts
- [WEA-324] - Allows to configure the Weasis AETitle for printer at the server side
- [WEA-326] - Show message when MPR cannot build a series without 3D positions
2.0.3 (2014-11-24)
Bug
- [WEA-294] - Thumbnails are not displayed when series are split
- [WEA-297] - Cannot reopen MPR from a generated series
- [WEA-299] - Somtimes start/stop buttons for controling download have no effect
- [WEA-300] - When changing the view selection the preset selection is lost
- [WEA-301] - Issue with the mechanism that clean the bundle cache when there is an error at launch
- [WEA-302] - The lens is not refreshed when panning
- [WEA-304] - Memory issue with some DICOM sequences when reading a DICOM file
New Feature
- [WEA-306] - Support DICOM AU modality with embeded audio player
Improvement
- [WEA-295] - Add PatientAge in attributes-view.xml to be configure by the user
- [WEA-296] - Allow to rebuild a series with MIP
- [WEA-298] - Improve file menu and contextual menu for central view
- [WEA-303] - Build MPR views with non square pixel images
- [WEA-305] - Skip reading private tags larger than 1 KB
2.0.2 (2014-08-05)
Bug
- [WEA-286] - Issue of reset and close command in full screen mode
- [WEA-287] - Patient and study annotations are not displayed with SC modality
- [WEA-289] - Position of dialog windows are not correct with multi-screens
- [WEA-290] - Color images with DICOM overlay are extremely slow to display
- [WEA-291] - Popup dialog does not appear on the right screen
- [WEA-293] - Cannot display non square binary overlay
Improvement
- [WEA-288] - Make telnet available only when all plugin commands are loaded
2.0.1 (2014-07-21)
Bug
- [WEA-271] - Cannot split series according to the Frame Type (enhanced DICOM)
- [WEA-272] - Erroneous DICOM presets with MR, PET and XA/XRF images containing Rescale Slope and Rescale Intercept
- [WEA-273] - Downloading progression label stays at 0%
- [WEA-274] - Charset issue when exporting series built by MPR
- [WEA-275] - Cannot read xml manifests from Osirix WEB server
- [WEA-278] - Rebuilding thumbnail from contextual menu does not work correctly
- [WEA-279] - Rendering issue of large rgb images
- [WEA-281] - Preset in MPR views are not initialized correctly
- [WEA-282] - Show pixel information for multi-channel images with channels superior to 8-bit
- [WEA-285] - Refreshing issues with the KO filter mode
Improvement
- [WEA-276] - Read correctly old DICOM date format
- [WEA-277] - Export the slected MPR view to clipboard
- [WEA-283] - Supporting 32-bit images in MPR and MIP
- [WEA-284] - Do not save crosshair tool into preferences when using MPR
2.0.0 (2014-06-27)
Bug
- [WEA-167] - Cannot export to Osirix when it is Osirix MD (or when application is renamed)
- [WEA-168] - Modality LUTs should not be applied in some cases
- [WEA-169] - Very small slider thick with Windows 7 Theme
- [WEA-170] - Pixel statistics on non-square pixel images are erroneous
- [WEA-172] - Do not download DICOM files (cannot read magic number)
- [WEA-175] - Problem of splitting a series containing a video and images
- [WEA-178] - When resizing a view, the image is shifted to the center
- [WEA-179] - Sometimes graphics are not visible when exporting a view through the clipboard
- [WEA-180] - Mixing tmp files when running several instances of Weasis (from different web sources)
- [WEA-182] - Weasis doesn't start on Windows 8
- [WEA-190] - Images are not displayed on Mac with Java 7
- [WEA-191] - Cannot print with annotations for some images
- [WEA-194] - DICOM print issue with some PrintSCP servers
- [WEA-197] - Keep the position of the toolbar after hiding
- [WEA-200] - Some US images (with a color Palette) are displayed in in black and white
- [WEA-202] - Missing images when exporting to JPEG with the option "Keep directory names"
- [WEA-210] - Cannot export big series in jpeg
- [WEA-211] - Error: cannot open more files (Ubuntu is limited by default to 1024)
- [WEA-212] - DICOMDIR Icons are not written correcty
- [WEA-213] - Toolbars have not a fixed position (showing / hiding)
- [WEA-215] - Shutdown of the application hangs sometimes on Windows and with JWS
- [WEA-216] - Do not display some Asiatic characters
- [WEA-217] - weasis2.0.0 can not open dcm file
- [WEA-219] - Random "Printer is not accepting job" PrinterExceptions
- [WEA-220] - The default property "weasis.look" doesn't work.
- [WEA-221] - Cannot display image with Modality LUT sequence and pixels outside the LUT table
- [WEA-222] - Lose W/L values when sorting the series stack
- [WEA-229] - Posterior and anterior annotations are reversed on sagittal images
- [WEA-230] - 3D Reconstruction of CT and MR are splitted in sub-series for each direction
- [WEA-231] - Some presets in DICOM file are not displayed correctly
- [WEA-237] - Security warning popup in Weasis with JRE 1.7.0_40 and JRE 1.7.0_45
- [WEA-247] - Cache issue when creating thumbnails (images cannot be loaded or are loaded two times)
- [WEA-252] - Overlay issue with multiframe
- [WEA-253] - Green border line with YBR_FULL Photometric Interpretation images
- [WEA-254] - Units are not display in DICOM SR view
- [WEA-255] - Cannot load images with Java 8
- [WEA-258] - Cannot resize correctly components in layout on a large screen
- [WEA-259] - Preferences are not saved when Weasis is launched with Java Web Start
- [WEA-261] - Popup message at start are hidden under the main Frame
- [WEA-262] - Download Interruption with https configuration
- [WEA-265] - Preferences of additional plugins are not saved
New Feature
- [WEA-17] - Customization of LUTs, Presets and displayed tags
- [WEA-133] - New window docking system
- [WEA-134] - Read and apply Key Object Selection to a series
- [WEA-135] - Read and apply Presentation State to a series
- [WEA-165] - Orthogonal MPR
- [WEA-166] - MIP(Maximum Intensity Projection) and Min-MIP
- [WEA-181] - Read and export DICOM ZIP file
- [WEA-196] - Display DICOM SR
- [WEA-206] - Draw text annotations
- [WEA-207] - Burn CDs
- [WEA-223] - Changing the unit of the spatial calibration
- [WEA-244] - Crosshair for series sharing the same FrameOfReferenceUID
- [WEA-248] - New API for image processing
- [WEA-251] - Real-world zoom
- [WEA-267] - Allow to embed the viewer in a web page
- [WEA-269] - Pixel probe tool
- [WEA-270] - API for building custom plug-ins (Tool, Toolbar, Import DICOM, Explort DICOM...)
- [WEA-292] - Handle series download globally or individually
Improvement
- [WEA-176] - Space bar shortcut for showing or hiding all the annotations
- [WEA-177] - Allows only a single instance of Weasis (portable) on Windows
- [WEA-186] - Windows portable executable now launches at first 32-bit Java Runtime
- [WEA-187] - Windows portable can incorporate a JVM for DICOM CD
- [WEA-192] - Show the selected Series in the DICOM explorer
- [WEA-198] - Not optimal display of large uncompressed DICOM images
- [WEA-199] - Reading illegal DICOM compressed file (encapsulation is missing)
- [WEA-201] - Improve the selection of thumbnails (same behaviour as a list)
- [WEA-203] - All actions in UI are disabled when the selected view has no image
- [WEA-204] - Can have multiple versions of preferences with the profile name in config.properties
- [WEA-205] - Add a position index and a generic way to configure toolbars (also for new toolbars in a plugin)
- [WEA-214] - Improve interface for building plugins
- [WEA-218] - Preset Creation
- [WEA-228] - Display Date Of Secondary Capture (0018,1012) for SC or OT
- [WEA-236] - Add options for the number of concurrent downloads
- [WEA-238] - Export DICOM KO, PR and SR
- [WEA-239] - Display thumbnails of series as tooltips in Dicom Export
- [WEA-240] - Propagate an error or warning message into Weasis through the manifest
- [WEA-241] - Sort alphabetically items correctly in each language
- [WEA-242] - Better display of DICOM metadata
- [WEA-243] - Display the level of compression in red (IHE BIR RAD TF-‐2: 4.16.4.2.2.5.8)
- [WEA-245] - Update to dcm4che 3.3
- [WEA-249] - Change the number of concurrent series and image downloads
- [WEA-250] - Improve DICOM metadata display
- [WEA-256] - Typo in DICOM attribute
- [WEA-257] - Improve series sorting
- [WEA-260] - Option for applying windowing on color images
- [WEA-263] - Improve full-screen mode when double clicking on a view
- [WEA-264] - Configuration on server side to customize the Weasis interface
- [WEA-266] - Separate language and the format of date and number in preferences
- [WEA-268] - Weasis-i18n (internationalization) improvements
1.2.9 (2014-04-01)
Bug
- [WEA-255] - Cannot load images with Java 8
- [WEA-258] - Cannot resize correctly components in layout on a large screen
- [WEA-259] - Preferences are not saved when Weasis is launched with Java Web Start
Improvement
1.2.8 (2013-12-11)
Bug
- [WEA-247] - Cache issue when creating thumbnails (images cannot be loaded or are loaded two times)
Improvement
- [WEA-240] - Propagate an error or warning message into Weasis through the manifest
- [WEA-241] - Sort alphabetically items correctly in each language
1.2.7 (2013-10-30)
Bug
- [WEA-229] - Posterior and anterior annotations are reversed on sagittal images
- [WEA-230] - 3D Reconstruction of CT and MR are splitted in sub-series for each direction
- [WEA-231] - Some presets in DICOM file are not displayed correctly
- [WEA-237] - Security warning popup in Weasis with JRE 1.7.0_40 and JRE 1.7.0_45
1.2.6 (2013-09-05)
Bug
- [WEA-202] - Missing images when exporting to JPEG with the option "Keep directory names"
- [WEA-210] - Cannot export big series in jpeg
- [WEA-211] - Error: cannot open more files (Ubuntu is limited by default to 1024)
- [WEA-212] - DICOMDIR Icons are not written correcty
- [WEA-213] - Toolbars have not a fixed position (showing / hiding)
- [WEA-215] - Shutdown of the application hangs sometimes on Windows and with JWS
- [WEA-216] - Do not display some Asiatic characters
- [WEA-219] - Random "Printer is not accepting job" PrinterExceptions
- [WEA-220] - The default property "weasis.look" doesn't work.
- [WEA-221] - Cannot display image with Modality LUT sequence and pixels outside the LUT table
- [WEA-222] - Lose W/L values when sorting the series stack
New Feature
- [WEA-207] - Burn CDs
Improvement
- [WEA-214] - Improve interface for building plugins
- [WEA-228] - Display Date Of Secondary Capture (0018,1012) for SC or OT
1.2.5 (2013-05-04)
Bug
- [WEA-190] - Images are not displayed on Mac with Java 7
- [WEA-191] - Cannot print with annotations for some images
- [WEA-193] - Cache images are not deleted when closing the application
- [WEA-194] - DICOM print issue with some PrintSCP servers
- [WEA-200] - Some US images (with a color Palette) are displayed in in black and white
Improvement
- [WEA-192] - Show the selected Series in the DICOM explorer
- [WEA-195] - Upgrade OSGI Felix framework to 4.2.0
- [WEA-199] - Reading illegal DICOM compressed file (encapsulation is missing)
- [WEA-201] - Improve the selection of thumbnails (same behaviour as a list)
1.2.4 (2013-01-26)
Bug
- [WEA-167] - Cannot export to Osirix when it is Osirix MD (or when application is renamed)
- [WEA-168] - Modality LUTs should not be applied in some cases
- [WEA-169] - Very small slider thick with Windows 7 Theme
- [WEA-170] - Pixel statistics on non-square pixel images are erroneous
- [WEA-171] - Cannot export multiframe correctly in JPEG or DICOM
- [WEA-172] - Do not download DICOM files (cannot read magic number)
- [WEA-175] - Problem of splitting a series containing a video and images
- [WEA-178] - When resizing a view, the image is shifted to the center
- [WEA-179] - Sometimes graphics are not visible when exporting a view through the clipboard
- [WEA-180] - Mixing tmp files when running several instances of Weasis (from different web sources)
- [WEA-182] - Weasis doesn't start on Windows 8
New Feature
- [WEA-185] - LUT toolbar, Rotation toolbar and Display Reset button
Improvement
- [WEA-173] - Skip private tags larger than 5 KB
- [WEA-174] - Upgrade to dcm4che 2.0.27
- [WEA-176] - Space bar shortcut for showing or hiding all the annotations
- [WEA-177] - Allows only a single instance of Weasis (portable) on Windows
- [WEA-183] - Upgrade Substance library to 7.2.1
- [WEA-184] - Add Bulgarian language
- [WEA-186] - Windows portable executable now launches at first 32-bit Java Runtime
- [WEA-187] - Windows portable can incorporate a JVM for DICOM CD
1.2.3 (2012-10-05)
Bug
- [WEA-164] - Context menu on the image does not appear on Windows
1.2.2 (2012-09-28)
Bug
- [WEA-162] - Any tool stops working when downloading DICOM SR
- [WEA-163] - Sometimes contextual menu on a view disappears after right clicking
1.2.1 (2012-09-21)
Bug
- [WEA-153] - Labels on image are not refresh properly when moving them
- [WEA-154] - Unchecking pixel padding option throws errors with some images
- [WEA-155] - Pixel padding values inversion with Monochrome1 images or when LUT is inversed
- [WEA-156] - Do not import DICOM encapsulated document (like pdf) from DICOMDIR
- [WEA-157] - Cannot load images any more when swithing between the version 1.1.2 and 1.1.3
- [WEA-158] - Does not take into account the preferred JRE defined in Mac OS X
- [WEA-159] - Out of memory when downloading very large DICOM files and with the option overrideDicomTagsList
- [WEA-161] - Double click conflict between stopping to draw a polylon and maximize a view in layout
- [WEA-188] - Weasis no longer works for my hospitals images, but works for other hospitals images
Improvement
- [WEA-160] - Upgrade OSGI Felix framework to 4.0.3
1.1.3 (2012-07-31)
Bug
- [WEA-108] - Images with extreme default W/L values are displayed in white
- [WEA-126] - Improve stabilization of playback speed in cineloops
- [WEA-127] - Removing patient or study doesn't close DICOM files
- [WEA-131] - Sorting cannot be applied to the same Series in several views
- [WEA-137] - Multiple weasis users on a same linux sytem
- [WEA-142] - Perimeter of the polygon measurement tool is erroneous
- [WEA-146] - Erroneous statistics with ROI on a color image
- [WEA-147] - ext-config.properties file not found in the web distribution
- [WEA-148] - YBR_FULL Images with overlay are not displayed with the right color model
- [WEA-149] - Uncompressed CT images with overlay cannot be displayed on Windows 64 bits
- [WEA-150] - Non square pixel images are not print correctly
New Feature
- [WEA-72] - Apply non linear LUT: VOI LUT from DICOM, sigmoid, log and inverse log
- [WEA-130] - Read modality LUT sequence
- [WEA-141] - New measurement tool: open polyline
- [WEA-144] - DICOM print (experimental)
- [WEA-145] - Display non DICOM images (jpeg, png, tiff...)
Improvement
- [WEA-128] - Commands to set layout, synch and left mouse action from OSGI console
- [WEA-129] - Add progress icon when exporting images
- [WEA-132] - Sort a Series by Content Time and Position/Orientation
- [WEA-136] - Translation in Turkish, Italian, Greek and Russian
- [WEA-138] - Handle Issuer Of PatientID tag to uniquely identify patients
- [WEA-139] - Shortcuts for presets
- [WEA-140] - Automatically clean Weasis cache after it cannot start or it crashes
- [WEA-143] - Display laterality in series annotations
- [WEA-151] - Improve the visibility of annotations when printing
1.1.2 (2012-03-01)
Bug
- [WEA-100] - Open series when loading throw an error sometimes
- [WEA-101] - Issue of launching Weasis successively every 1-3 seconds
- [WEA-104] - The clickable area of stop/resume downloads is shifted for non-square thumbnail
- [WEA-106] - Invalid numeric values makes DICOM unreadable
- [WEA-107] - YBR_FULL_420 and YBR_FULL_422 images cannot be displayed
- [WEA-114] - Weasis doesn't start properly when launching it from different locations and having the same version number
- [WEA-115] - Shortcut conflicts
- [WEA-116] - Selecting empty view does not change the patient in DICOM explorer
- [WEA-120] - Wrong file size for multiframe Series
- [WEA-121] - Weasis cannot start on Windows server 2008 R2
- [WEA-122] - Floating Explorer: Sometimes thumbnails of a split series are not displayed
- [WEA-123] - Popup menus throw errors
New Feature
- [WEA-28] - Print capabilities
- [WEA-105] - Read and import images from DICOMDIR
- [WEA-110] - Read DICOM CD
- [WEA-118] - Package bundle in pack200 compression
- [WEA-124] - Export to DICOM (DICOM CD), JPEG, PNG and TIFF
Improvement
- [WEA-73] - When a transfer syntax is not supported, automatically request the uncompressed syntax to the WADO server
- [WEA-102] - Add Reflex angle measurement (360 degrees - angle)
- [WEA-103] - Common behavior for General Preferences configuration
- [WEA-109] - Upgrade to Felix framework 4.0.2
- [WEA-111] - Update to dcm4che 2.0.26
- [WEA-112] - Update to Substance 7.1
- [WEA-113] - Add language packs in Weasis portable
- [WEA-117] - Activation of rolling log in preferences
- [WEA-119] - Displaying date with a short textual representation of a month, three letters in the selected language
- [WEA-125] - German translation
1.1.1 (2011-11-21)
Bug
- [WEA-60] - Some DICOM files are not deleted of the temp directory when closing the application
- [WEA-77] - Sometimes thumbnails of a split series are not displayed
- [WEA-79] - Cannot open a large number of DICOM files On Linux
- [WEA-81] - When images have the same patient's name and different patientIDs, only one patient is displayed
- [WEA-82] - Non square pixel images without pixel spacing value (only pixel aspect ratio) are not supported
- [WEA-84] - Rectangular images are shifted with a rotation of 90, 180 or 270 degrees
- [WEA-91] - Image containting DataSet Trailing Padding element (FFFC,FFFC) cannot be read (DCM-478)
- [WEA-99] - Cannot sort correctly some multiframe
New Feature
- [WEA-74] - Cine toolbar and shortcuts to start and stop
- [WEA-75] - Display DICOM shutter
- [WEA-87] - Supported MPEG-4 AVC/H.264 High Profile / Level 4.1
Improvement
- [WEA-76] - Add language packs in Weasis Portable
- [WEA-78] - Keep the path of the last open folder in the import DICOM dialog
- [WEA-80] - Thumbnails are built and displayed asynchronously (do not block UI any more)
- [WEA-83] - All the display parameters are reset when changing the series
- [WEA-85] - Display more accurate information of the image plane orientation
- [WEA-86] - Keeps Look and Feels preference when the version is changing
- [WEA-88] - Extending the provided config.properties file
- [WEA-89] - New command "dicom:close -a", close all patients
- [WEA-90] - Upgrade to Felix framework 4.0.1 (OSGI 4.3)
- [WEA-92] - Display available language packs in preferences
- [WEA-93] - Menu Display to show or hide toolbars and tools
- [WEA-94] - Make the round icon of the mini-tool slider more visible (for substance L&F)
- [WEA-95] - Show or hide DICOM Pixel Padding in display panel.
- [WEA-96] - Adapting SUV Calculation to vendor-neutral pseudo-code
- [WEA-97] - Always detect DICOM files by its magic number
- [WEA-98] - Show a global progression icon for any DICOM import method
1.1.0 (2011-10-05)
Bug
- [WEA-40] - Cannot load weasis-i18n with dcm4chee-web3
- [WEA-45] - Accept empty values for IDs in weasis-pacs-connector
- [WEA-50] - Keystrokes for Window/Level (W), Measure (M) and Context Menu (Q) does not work
- [WEA-53] - Cannot resume downloading series after changing priority
- [WEA-56] - Only one series is removed when several are selected
- [WEA-57] - Series progress bar is not always refresh
- [WEA-58] - Weasis Portable hangs when loading images from the directory defined by the property "weasis.portable.dicom.directory"
- [WEA-59] - Weasis Portable does not display split series when loading images of the CD-ROM folder
- [WEA-61] - Error of buiding the views of preferences (OSGI service)
- [WEA-70] - Out Of Memory Error when measuring the whole image (CR)
New Feature
- [WEA-43] - Manage in properties which IDs are allowed and which combination is necessary
- [WEA-51] - Add series to the layout (change the layout if it cannot contain all the series)
- [WEA-52] - New measurements tools (three points circle, polyline, perpendicular, parallel, open anlge, four points angle, Cobb's angle) and more display properties
- [WEA-62] - Cut, copy and paste drawings into another view
- [WEA-64] - Computing SUV for PET images
- [WEA-65] - Anonymize DICOM annotations in display
- [WEA-66] - Add in xsd schema httpTag (add tags in http request) and DirectDownloadFile (direct URL, not WADO)
- [WEA-67] - Export the selected view to clipboard (with all annotations in anonymized mode)
- [WEA-68] - New command for loading a DICOM from an URL (dicom:get -r URL)
Improvement
- [WEA-41] - Overriding jnlp template of weasis-pacs-connector
- [WEA-42] - Add Accession Number as a request ID
- [WEA-44] - Limit access for weasis-pacs-connector
- [WEA-46] - weasis-pacs-connector and weasis can be on different servers
- [WEA-47] - Upgrade to Felix framework 3.2.2
- [WEA-48] - Supports WADO xml references file embedded in Java Web Start (jnlp)
- [WEA-49] - From Weasis 1.1.0 the internationalized package (i18n) can be applied to any version
- [WEA-54] - Shows indeterminate progress bar for large unique file (video, multiframe...) of a series
- [WEA-55] - Images with non-square pixels are rectified and displayed as square pixels
- [WEA-63] - Resize the views of layouts
- [WEA-69] - Contextual menu for drawings (when selected)
- [WEA-71] - Some advanced preferences are accessible only by superuser
1.0.9 (2011-05-08)
Bug
- [WEA-30] - Java Version 6 Update 24 Breaks Weasis
- [WEA-36] - Cannot resize Jpeg2000 images with negative values (pixel representation = 1)
- [WEA-37] - Cannot run the Weasis portable distribution if executable path contains space
Improvement
- [WEA-38] - Resizing the magnifying lens does not update the image position
- [WEA-39] - Rebuilding thumbnail manually from first, middle or last stack image
1.0.8 (2011-03-10)
Bug
- [WEA-8] - Issues when JAI is already installed
- [WEA-16] - Sometimes a thumbnail in the series list cannot be dragged
- [WEA-18] - Image are not sorted correctly when merge again a split Series
- [WEA-19] - Drawings are preserved when changing image with DICOM multiframe
- [WEA-21] - Context menu resets the pan action
- [WEA-24] - Cannot open images when the viewer preferences contain corrupted values
- [WEA-26] - Measurements are deleted when displaying the same Series int two views
- [WEA-27] - FolderSubmitCtrl2 messes up browser sessions (dcm4chee integration)
- [WEA-29] - Clicking on the start button in the cine toolbar accelerates the cine speed
- [WEA-32] - Does not display the whole image when performing a rotation
- [WEA-35] - The pixel values of Pixel Padding Value (0028,0120) and (0028,0121) are random gray levels (should be always black)
New Feature
- [WEA-9] - Integration of new Look and Feels
- [WEA-11] - A new zooming tool: a magnifying lens
- [WEA-12] - Reading encapsulated DICOM objects and DICOM MPEG
- [WEA-14] - Standalone version of Weasis
- [WEA-15] - Add image filtering capacities (blur, sharpen...) in a view
- [WEA-20] - Exporting images into Osirix
- [WEA-25] - Change or add spatial calibration
Improvement
- [WEA-10] - Handle the option of displaying the confirmation message when closing the application
- [WEA-13] - Changing zoom quality
- [WEA-22] - Display limited DICOM information
- [WEA-23] - Open Series by dragging them into the empty central area
- [WEA-31] - No syncrhonization nor cross reference lines in multiframe series
- [WEA-33] - Improve splitting rules for DICOM Multiframe Series
- [WEA-34] - Pause/Resume a Series download by clicking on the progress bar
1.0.7 (2010-11-24)
Bug
- [WEA-4] - Does not display properly 8 bits RGB snapshots
- [WEA-6] - Import and export sub-menus are not displayed
- [WEA-7] - Transfer syntax argument does not appear in the WADO request
Improvement
- [WEA-5] - Japanese translation for weasis.
1.0.6 (2010-11-04)
Bug
- [WEA-2] - Does not sort Study (by date) and Series (by series number, uid) sometimes
- [WEA-3] - Cannot display the first image downloaded
Task
- [WEA-1] - Initial import of Weasis code and Maven build scripts
* This Changelog was automatically generated by github_changelog_generator