Skip to content

Latest commit

 

History

History
344 lines (266 loc) · 17 KB

User_Manual.md

File metadata and controls

344 lines (266 loc) · 17 KB

User Manual AhoyDTU (on ESP8266)

Version #{VERSION}#

Introduction

See the repository README.md

Setup

Assuming you have a running ahoy-dtu and you can access the setup page. In the initial case or after click "erase settings" the fields for the inverter setup are empty.

Set at least the serial number and a name for each inverter, check "reboot after save" and click the "Save" button.

MQTT Publish

The AhoyDTU will publish on the following topics

<TOPIC>/#

Topic Example Value Remarks Retained
comm_start 1672123767 inverter communication start, based on sunrise, UTC timestamp true
comm_stop 1672155709 inverter communication stop, based on sunset, UTC timestamp true
device AHOY-DTU configured device name true
dis_night_comm true setting if night communication is disabled true
free_heap 17784 free heap of ESP in bytes false
mqtt connected shows MQTT status true
status 1 see table below true
sunrise 1672124667 sunrise, UTC timestamp true
sunset 1672154809 sunset, UTC timestamp true
uptime 73630 uptime in seconds false
version 0.5.61 current installed verison of AhoyDTU true
wifi_rssi -75 WiFi signal strength false
ip_addr 192.168.178.25 WiFi Station IP Address true
status code Remarks
0 offline
1 partial
2 online

<TOPIC>/<INVERTER_NAME_FROM_SETUP>/#

Topic Example Value Remarks Retained
available 2 see table below true
last_success 1672155690 UTC Timestamp true
ack_pwr_limit true fast information if inverter has accepted power limit false
status code Remarks
0 not available and not producing
1 available but not producing
2 available and producing

<TOPIC>/<INVERTER_NAME_FROM_SETUP>/ch0/#

Topic Example Value Remarks
U_AC 233.300 actual AC Voltage in Volt
I_AC 0.300 actual AC Current in Ampere
P_AC 71.000 actual AC Power in Watt
Q_AC 21.200 actual AC reactive power in var
F_AC 49.990 actual AC Frequency in Hz
PF_AC 95.800 actual AC Power factor
Temp 19.800 Temperature of inverter in Celsius
EVT 9.000 Last Event/Alarm Message Index
YieldDay 51.000 Energy converted to AC per day in Watt hours (measured on DC)
YieldTotal 465.294 Energy converted to AC since reset Watt hours (measured on DC)
P_DC 74.600 actual DC Power in Watt
Efficiency 95.174 actual ration AC Power over DC Power in percent
FWVersion 10012.000 Firmware version eg. 1.00.12
FWBuildYear 2020.000 Firmware build date
FWBuildMonthDay 624.000 Firmware build month and day eg. 24th of june
HWPartId 100.000 Hardware Id
PowerLimit 80.000 actual set point for power limit control AC active power in percent
LastAlarmCode 1.000 Last Alarm Code eg. "inverter start"

<TOPIC>/<INVERTER_NAME_FROM_SETUP>/ch<CHANNEL_NUMBER>/#

<CHANNEL_NUMBER> is in the range 1 to 4 depending on the inverter type

Topic Example Value Remarks
U_DC 38.900 actual DC Voltage in Volt
I_DC 0.640 actual DC current in Ampere
P_DC 25.000 actual DC power in Watt
YieldDay 17.000 Energy converted to AC per day Watt hours per module/channel (measured on DC)
YieldTotal 110.819 Energy converted to AC since reset Watt hours per module/channel (measured on DC)
Irradiation 5.65 ratio DC Power over set maximum power per module/channel in percent

Active Power Limit via Serial / Control Page

URL: /serial

You can change the setting in the following manner. Decide if you want to set

  • an absolute value in Watt
  • an relative value in percent based on the maximum Power capabilities of the inverter

and if this settings shall be

  • persistent
  • not persistent

after a power cycle of the inverter (P_DC=0 and P_AC=0 for at least 10 seconds)

The user has to ensure correct settings. Remember that for the inverters of 3rd generation the relative active power limit is in the range of 2% up to 100%. Also an absolute active power limit below approx. 30 Watt seems to be not meanful because of the control capabilities and reactive power load.

Control via MQTT

Generic Information

The AhoyDTU subscribes on following topics:

  • <TOPIC>/ctrl/limit/<INVERTER_ID>
  • <TOPIC>/ctrl/restart/<INVERTER_ID>
  • <TOPIC>/setup/set_time

👆 <TOPIC> can be set on setup page, default is inverter.

👆 <INVERTER_ID> is the number of the specific inverter in the setup page.

Inverter restart

<TOPIC>/ctrl/restart/<INVERTER_ID>

Example:

inverter/ctrl/restart/0

Power Limit relative (non persistent) [%]

<TOPIC>/ctrl/limit/<INVERTER_ID>

with a payload [2 .. 100]

NOTE: optional a % can be sent as last character

Example:

inverter/ctrl/limit/0     70

Power Limit absolute (non persistent) [Watts]

<TOPIC>/ctrl/limit/<INVERTER_ID>

with a payload [0 .. 65535]

NOTE: the unit W is necessary to determine an absolute limit

Example:

inverter/ctrl/limit/0     600W

Power Limit persistent

This feature was removed. The persisten limit should not be modified cyclic by a script because of potential wearout of the flash inside the inverter.

Control via REST API

Generic Information

The rest API works with JSON POST requests. All the following instructions must be sent to the /api endpoint of the AhoyDTU.

👆 <INVERTER_ID> is the number of the specific inverter in the setup page.

Inverter Power (On / Off)

{
    "id": <INVERTER_ID>,
    "cmd": "power",
    "val": <VALUE>
}

The <VALUE> should be set to 1 = ON and 0 = OFF

Inverter restart

{
    "id": <INVERTER_ID>,
    "cmd": "restart"
}

Power Limit relative persistent [%]

{
    "id": <INVERTER_ID>,
    "cmd": "limit_persistent_relative",
    "val": <VALUE>
}

The VALUE represents a percent number in a range of [2 .. 100]

Power Limit absolute persistent [Watts]

{
    "id": <INVERTER_ID>,
    "cmd": "limit_persistent_absolute",
    "val": <VALUE>
}

The VALUE represents watts in a range of [0 .. 65535]

Power Limit relative non persistent [%]

{
    "id": <INVERTER_ID>,
    "cmd": "limit_nonpersistent_relative",
    "val": <VALUE>
}

The VALUE represents a percent number in a range of [2 .. 100]

Power Limit absolute non persistent [Watts]

{
    "id": <INVERTER_ID>,
    "cmd": "limit_nonpersistent_absolute",
    "val": <VALUE>
}

The VALUE represents watts in a range of [0 .. 65535]

Developer Information REST API (obsolete)

In the same approach as for MQTT any other SubCmd and also MainCmd can be applied and the response payload can be observed in the serial logs. Eg. request the Alarm-Data from the Alarm-Index 5 from inverter 0 will look like this:

{
    "inverter":0,
    "tx_request": 21,
    "cmd": 17,
    "payload": 5,
    "payload2": 0
}

Zero Export Control (needs rework)

  • You can use the mqtt topic <TOPIC>/devcontrol/<INVERTER_ID>/11 with a number as payload (eg. 300 -> 300 Watt) to set the power limit to the published number in Watt. (In regular cases the inverter will use the new set point within one intervall period; to verify this see next bullet)
  • You can check the inverter set point for the power limit control on the topic <TOPIC>/<INVERTER_NAME_FROM_SETUP>/ch0/PowerLimit 👆 This value is ALWAYS in percent of the maximum power limit of the inverter. In regular cases this value will be updated within approx. 15 seconds. (depends on request intervall)
  • You can monitor the actual AC power by subscribing to the topic <TOPIC>/<INVERTER_NAME_FROM_SETUP>/ch0/P_AC 👆 This value is ALWAYS in Watt

Firmware Version collection

Gather user inverter information here to understand what differs between some inverters. To get the information open the URL /api/record/info on your AhoyDTU. The information will only be present once the AhoyDTU was able to communicate with an inverter.

Name Inverter Typ Bootloader V. FWVersion FWBuild [YYYY] FWBuild [MM-DD] HWPartId
DanielR92 HM-1500 1.0.16 2021 10-12 100
isdor HM-300 1.0.14 2021 12-09 102
aschiffler HM-1500 1.0.12 2020 06-24 100
klahus1 HM-300 1.0.10 2020 07-07 102
roku133 HM-400 1.0.10 2020 07-07 102
eeprom23 HM-1200 0.1.0 1.0.18 2021 12-24 269619201 18:21:00 HWRev 256
eeprom23 HM-1200 2t 0.1.0 1.0.16 2021 10-12 269619207 17:06:00 HWRev 256
fila612 HM-700 1.0.10 2021 11-01 104
tfhcm TSUN-350 1.0.14 2021 12-09 102
Groobi TSOL-M400 1.0.14 2021 12-09 102
setje HM-600 1.0.08 2020 07-10 104
madmartin HM-600 0.1.4 1.0.10 2021 11-01 104
lumapu HM-1200 0.1.0 1.0.12 2020 06-24
chehrlic HM-600 1.0.10 2021 11-01 104
chehrlic TSOL-M800de 1.0.10 2021 11-01 104
B5r1oJ0A9G HM-800 1.0.10 2021 104
B5r1oJ0A9G HM-800 1.0.10 2021 104
tomquist TSOL-M1600 1.0.12 2020 06-24 100
rejoe2 MI-600 236 2018 11-27 17
rejoe2 MI-1500 1.0.12 2020 06-24 100
dragricola HM-1200 1.0.16 2021 10-12 100
dragricola MI-300 230 2017 08-08 1

Developer Information about Command Queue

After reboot or startup the ahoy firmware it will enque three commands in the following sequence:

  1. Get active power limit in percent (SystemConfigPara = 5 // 0x05)
  2. Get firmware version (InverterDevInform_All = 1 // 0x01)
  3. Get data (RealTimeRunData_Debug = 11 // 0x0b)

With the command get data (RealTimeRunData_Debug = 11 // 0x0b) the alarm message counter will be updated. In the initial case then aonther command is queued to get the alarm code (AlarmData = 17 // 0x11).

This command (AlarmData = 17 // 0x11) will enqued in any operation phase if alarm message counter is raised by one or greater compared to the last request with command get data (RealTimeRunData_Debug = 11 // 0x0b)

In case all commands are processed (_commandQueue.empty() == true) then as a default command the get data (RealTimeRunData_Debug = 11 // 0x0b) will be enqueued.

In case a Device Control command (Power Limit, Off, On) is requested via MQTT or REST API this request will be send before any other enqueued command. In case of a accepted change in power limit the command get active power limit in percent (SystemConfigPara = 5 // 0x05) will be enqueued. The acceptance is checked by the reponse packets on the devive control commands (tx id 0x51 --> rx id 0xD1) if in byte 12 the requested sub-command (eg. power limit) is present.

How To

Sunrise & Sunset

In order to display the sunrise and sunset on the start page, the location coordinates (latitude and longitude) must be set in decimal in the setup under Sunrise & Sunset. If the coordinates are set, the current sunrise and sunset are calculated and displayed daily. If this is set, you can also tick "disable night communication", then sending to the inverter is switched off outside of the day (i.e. at night), this avoids unnecessary communication attempts and thus also the incrementing of "RX no anwser". Here you can get easy your GeoLocation: https://www.mapsdirections.info/en/gps-coordinates.html

Commands and informations

Turn On - turns on the inverter/feeder (LED flashes green if there is no error) Turn Off - switches off the inverter/feeder (LED flashes fast red), can be switched on again with Turn On or by disconnecting and reconnecting the DC voltage Restart - restarts the microcontroller in the inverter, which deletes the error memory and the YieldDay values, feed-in stops briefly and starts with the last persistent limit Send Power Limit:

  • A limitation of the AC power can be sent in relative (in %) or in absolute (Watt).
  • It can be set to a different value non-persistently (temporarily) at any time (regardless of what you have set for persistent), this should be normal in order to limit the power (zero feed/battery control) and does not damage the EEPROM in the WR either.
  • With persistent you send a saving limit (only use it seldom, otherwise the EEPROM in the HM can break!), This is then used as the next switch-on limit when DC comes on, i.e. when the sun comes up early or the WR on batteries is switched on the limit is applied immediately when sending, like any other, but it is stored in the EEPROM of the WR.
  • A persistent limit is only needed if you want to throttle your inverter permanently or you can use it to set a start value on the battery, which is then always the switch-on limit when switching on, otherwise it would ramp up to 100% without regulation, which is continuous load is not healthy.
  • You can set a new limit in the turn-off state, which is then used for on (switching on again), otherwise the last limit from before the turn-off is used, but of course this only applies if DC voltage is applied the whole time.
  • If the DC voltage is missing for a few seconds, the microcontroller in the inverter goes off and forgets everything that was temporary/non-persistent in the RAM: YieldDay, error memory, non-persistent limit.

Update your AHOY-DTU Firmware

To update your AHOY-DTU, you have to download the latest firmware package. Here are the latest stable releases and latest development builds available for download. As soon as you have downloaded the firmware package, unzip it. On the WebUI, navigate to Update and press on select firmware file. From the unzipped files, select the right .bin file for your hardware and needs.

  • If you use an ESP8266, select the file ending with esp8266.bin
  • If you use an ESP8266 with prometheus, select the file ending with esp8266_prometheus.bin
  • If you use an ESP32, select the file ending with esp32.bin
  • If you use an ESP32 with prometheus, select the file ending with esp32_prometheus.bin

Note: if you want to use prometheus, the usage of an ESP32 is recommended, since the ESP8266 is at its performance limits and therefore can cause stability issues.

After selecting the right firmware file, press update. Your AHOY-DTU will now install the new firmware and reboot.

Additional Notes

MI Inverters

  • AhoyDTU supports MI type inverters as well, since dev. version 0.5.70.
  • MI inverters are known to be delivered with two different generations of firmwares: inverters with serial numbers 10x2 already use the 3rd generation protocol and behave just like the newer HM models, the follwoing remarks do not apply to these.
  • Older MI inverters (#sn 10x1) use a different rf protocol and thus do not deliver exactly the same data. E.g. the AC power value will therefore be calculated by AhoyDTU itself, while other values might not be available at all.
  • Single and dual channel 2nd gen. devices seem not to accept power limiting commands at all, the lower limit for 4-channel MI is 10% (instead of 2% for newer models)
  • 4-channel MI type inverters might work, but code still is untested.