Norm onboarding requires uneasy co-existence with Dialyzer #53
Comments
If you're here because you're searching for this problem, I guess we never did make Norm compatible with Dialyzer. Here are some workaround for the errors: Unknown types: run
def project do
[
dialyzer: [
ignore_warnings: "dialyzer.ignore-warnings",
flags: [:no_opaque],
# ...
end If you're using ElixirLS you'll need to add the same flag to its options, e.g. in your VS Code { "elixirLS.dialyzerWarnOpts": [ "no_opaque" ] } Still feeling too brutal? Need those warnings elsewhere? Add a dialyzer module attribute to suppress those specific warnings: @dialyzer {:no_opaque, module: 0, function: 0, term: 0}
defguard(is_term(_) when true)
def module, do: with_gen(spec(is_atom()), StreamData.atom(:alias))
def function, do: with_gen(spec(is_atom()), StreamData.atom(:alphanumeric))
def term, do: with_gen(spec(is_term), StreamData.term())
def mfa, do: {module(), function(), coll_of(term(), into: [])} |
Maybe I'm missing something but this seems like a pretty innocuous change. So I'm happy to add it if. My main concern is just that we don't run dialyzer in Norm's CI suite. Which means it wouldn't be enforced atm. |
I'm pretty comfortable with |
That seems great. Feel free to submit a PR. |
I've been looking into this more. From what I can tell this is actually a stream_data issue and doesn't have anything to do with Norm. Its also possible that I'm reading this wrong. I added dialyzer to Norm, and added a new module like so: defmodule Norm.Test do
import Norm
def foo do
with_gen(spec(is_atom), StreamData.atom(:alphanumeric))
end
end After 10,000 years waiting for dialyzer to build a PLT, realizing that stream_data wasn't included in the PLT, reconfiguring and waiting another 10,000 years, dialyzer eventually spits out this error:
We're not actually doing anything wrong here. We're just using stream_data's API. I think the issue is that stream_data hasn't added explicit type specs to it's APIs, which it has to do if |
You want to add some Norm for that
with_gen/2
goodness, but Dialyzer got there first. The first argument ofwith_gen/2
isn't opaque,t:StreamData.t/0
is, and your console is all red:If it wouldn't make @keathley break out in a rash, maybe an
@opaque
of our own and a sprinkling of@spec
would make it easier?The text was updated successfully, but these errors were encountered: